Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹65.8 L
EMD Value
₹1.3 L
Closing Date
13 Aug 2024, 5:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Aircraft Overhaul Division, Nasik
Aircraft Overhaul Division, Nasik
Replacement of tiles miscellaneous civil and electrical works at Swimming pool in HAL Township
8867
NK/FW/C-1582/2024-25
Works
Mig Complex - Aircraft Overhaul Divn - Nasik - Works - Contracts
₹0
₹1.3 L
13 Aug 2024
23 Jul 2024
23 Jul 2024
13 Aug 2024
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, etc.
Address for Correspondence:
PAN No.:
Contact details
I.T Returns for past 03 years (Assesment Year)
Related Document to be Uploaded to e-procurement portal.
Annual financial turn over during the last 3 years (Financial Year), ending 31st March 2023 [Annual financial turn over during the last 3 years should not be less than 30% of the estimated amount put to tender.]
Turn Over (Rupees in Lakhs)
ESI, GST & PF Nos. with proof
Related Document to be Uploaded to e-procurement portal.
Bank(s) details: [Annexure E-5 to be uploaded in original]
Related Document to be Uploaded to E- Procurement Portal. (Note:Original ECS dully sealed and signed by Bank along with cancelled cheque to be uploaded)
Latest Bankers Solvency Certificate from Nationalized or Scheduled Bank issued within a period of 12 months from the final date of Submission of Tender. (Should not be less than 40% of the Approx. estimated amount put to tender.)
Related Document to be Uploaded to e-procurement portal.
Experience of having successfully completed similar works "(As per "Work Details" table of Etender notice) ." during last 7 years ending on previous day of last day of submission of tender should be either of the following. [Latest work experience (completion) certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost of Amount put to the tender OR (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost of Amount put to the tender OR (iii) ONE similar completed work each costing not less than the amount equal to 80% of the estimated cost of Amount put to the tender
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
License for execution of Electrical works and other specialized works from the concerned authorities /organizations/bodies (applicable for Electrical works combined with Civil works)
Details of person holding the power of Attorney (If different from contact person)
Related Document to be Uploaded to e-procurement portal.
Acceptance by party for Scope of work as per BOQ and Tender terms & conditions
DECLARATION
Please write "Accepted/ Not-accepted"
DECLARATION
Please write "Accepted/ Not-accepted"
Specification
Dismantling the existing floor tile and wall tiles thickness less than 25 mm including stacking material with in 50 m lead cleaning the premises etc complete as specified and as directed .
Demolishing the existing brick/stone masonry manually/ by mechanical built in cement mortar at any position and stacking of servisible material and for disposal of unusable material within 50 mts. lead complete as specified and as directed.
Demolishing the existing cement concrete manually/ by mechanical of any thickness nominal concrete 1:3:6 or richer concrete and at any position includuing taking out the debris up to 50 mts lead , stacking for further disposal complete as specified and as directed.
Demolishing the existing reinforced cement concrete of any description and in any position including cutting the reinforcement wherever required, and stacking of steel bar and removal of unservisible material within 50 mts lead for further disposal complete as specified and as directed.
Taking down cement plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water to receive plaster ,tiles, etc. including stacking material with in 50 m lead cleaning the premises all complete as specified and as directed.
Removing carefully the existing R.C.C jallies thickness more than 40 mm fixed in column, brick masonry at any position and level including stacking material with in 50 m lead ,cleaning complete as specified and as directed by EIC.
Fixing of existing RCC jallies in CM 1:4 in proper level and line after cleaning , curing complete as specified and as directed by EIC.(The RCC jallies removed in item No. 6 to be used for this item)
Earth work in excavation by (hydralic excavator ) / manual means in foundation ,trenches not exceeding 1.5 m wide not exceeding 10 sqm in plan & incuding dressing of sides and ramming of bottoms for all lift,incuding getting out the excavated soil and disposal of suplus excavted soil as dircted within a lead of 50 m.
Taking down glass doors & glass partition (Area beyond 3.00 sqm) including taking out the supporting frame work & removing the holdfast from wall & floor and stacking unservisible material within 50 mts lead for further disposal complete all as specified & as directed by Engineer Incharge.
Taking down carefully the existing FRP sheet roof of any description & at any position by removing/cutting the nutbolt fixed with supporting structural steel frame work removing unservisible material to 50 m for further disposal.all as specified & as directed by Engineer Incharge.
Providing precast cement concrete Jali of 50 mm thick in 1:2:4 (1 cement: 2 Coarse sand (zone- III): 4 Graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening , cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.
Providing & fixing precast cement concrete solid building blocks /post/pillar 150x150mm thick & Beam 55x65mm in cement concrete 1:1.5:3 (using 20mm nominal size graded stone agreegate) , setting in mortar CM 1:3 ,curing complete as specified and as directed by EIC.
Providing and fabricating and fixing in position framed work such as grills, grating,frame for grilll, grating etc including all cutting, welding, bending, drilling etc.including one coat odf steel primer complete as specified and as directed by EIC.
Providing and applying one coat red oxide zinc cromets & two or more coats of approved quality and brand synthetic enamel paint of approved shade including necessary preparatory works, cleaning complete as specified and as directed.
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm X 19mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 m wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both side to form lock rail. Top, bottom and lock rail shall be provided both side of the pannel.. 10 mm ( 5mm x 2) thick 20 mm wide cross PVC sheet to be provided as a gap insert for top rail and bottom rail ,paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded / sealed to the styles & rails with 7 mm ( 5mm+2mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' channel using PVC solvent adhesive etc. Complete as per direction of Engineer-in-charge, manufacturer's specification and drawing.
30 mm thick pre laminated PVC door shutter
Providing and fixing of Swimming pool Avion Porcelain mosaics tiles of 48x48 mm with 6mm thick approx and 306x306 mm sheet size with 36 pieces having coverage 1.01Sqft.per sheet and joint gap 3mm on floor or wall in line, level and fixing by using chemical cement addhesive including removing the existing tiles and grinding wall and floor completly and finishing of surface and joint to be filled with Epoxy based tiles grout of weber from Saint Gobin. (remove the spacers bar before grouting, grout joints must be clean and free from dirt,dust & foregin matter before appling epoxy material on tiles joint) curing cleaning etc. complete all as specifide and as directed. ( Do not clean the tiles with acid cleaners all joints to be clean by washing with water/detergent).
Brick work with non modular fly ash bricks confirming to IS 12894 class designation 10 average compressive strength in plinth level and above in super structurel in cement mortor 1:4 (1 cement :4 coarse sand) and as specified and as directed by EIC
Providing and casting in situ plain cement concrete 1:3:6, using 40 mm graded stone aggregate for foundation including necessary form work, mixing, placing in position, compacting, curing, complete as directed.
Providing & rendering 18 mm cement plaster in two coats under layer 12 mm thick cement plaster1:5 (1 cement:5 coarse sand)finished with a top layer 6mm thick cement plaster 1:3(1 cement :3 fine sand) finished rough with sponge
Providing centering & formwork for cornics/coping plain or reinforced cement concrete straight, horizontal, sloping as required including all cutting & waste, centering, bracing, strutting and removing the form after the retention period complete as specified & as directed by EIC.
Providing and laying in position mild Steel rainforcement for RCC work including strainghtening ,cutting ,bending placing in position and binding all complete up to plingth level . complete as specified and as directed by EIC.
Providing and laying 1:1.5:3 reinforced cement concrete using 20mm graded aggregate including mixing, placing in position, compacting, vibrating, curing, finishing the surface of concrete smooth/ hacked as required complete as specifed as directed by Engineer Incharge.
Providing ,fabricating and errecting in position steel work in built up tubular (round Sqare or reactangular hallow tubes etc) trusses etc including cutting ,hoisting fixing in position and applying a priming coat of approved steel primer including welding and bolting with special shaped washers etc complete as specified and as directed by EIC
Providing & fixing UV stablised fibre glass reinforced plastic sheet roofing of 2mm thick flat ,including fixing with polymer coated J or L hooks bolts and nut 8 mm dia, G.I plain /bitumen washers complete but excluding the cost of purline ,rafters trusses etc. The sheet shall be manufactured out of 2400 tex panel rovigs incorporating minimum 0.3 % ultravoilate stabilaser in resin system under approximately 2400 psi & hot curd . They shall be of uniform pigmentation & thickness without airpockets & shall conform to I.S. 10192 & I.S. 12866. The sheet shall be opque or translucent , clear or pigmented texured or smooth as specified,
Providing and applying two coats of acrylic smooth exterior paint of required shed.over a new work (Two or more coat applied (@1.67 ltr /10 sqm )over and inculding priming coat of exterior primer applied @ 0.90 litre /10 Sqm., cleaning complete as specified and as directed.
Disposing the debris and surplus soil up to a distance of 5 KM. including spreading and levelling complete as directed.
Providing & laying swimming pool overflow grating of high grade plastic /PVC of suitable design for water from a swimming pool to minimise , to allow easy seepage of water into a drain which is connected to drainage system of pool. Grating should be anti-slippery,chemical , corrosion registance. and very comfortable for use.It should be of required & sutable sizes with approved colours. It should be injection moulded design & with a perfect finish. It should be easy to install and easy to clean.It can be used in both curved and straight overflows.Height and lenght should be as per requirement & ideal for overflow system of swimming pools .(size 12-20 inch appx.) complete as specified and as directed.by EIC. ( Contractor should visit to swimming pool before coating rate.)
Providing and fixing in position i st quality Glazed ceramic tiles of size any size or more (thickness to be specified by manufactureer ),of first quality confirming to I.S. 15622 of approved make, in all coloures, shades except burgundy,bottle green,black of any sise as approved by engineer -In-charge over 12mm thick backing coat cement morter 1;3 (1 cement 3 coarse sand ) jointing with grey cement slurry @3.30 kg /m2 including grouting the joints with white cement and matching the pigment. etc complete as specified and as directed.
Providing & laying (MAT / ANTISKID) vitrified tiles of 600mm x 600 mm ( thickness to be specified by manufactureer. With water absorption less than 0.08 % and confirming to I.S. 15622, of approved brand & manufacturer, in all coloures and shade, laid on 20 mm thick cement morter 1:4 (1cemnt & 4 coarse sand) jointing with grey cement slurry at 3.30 kg /m2 including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the 0 chipping dimond cutter only. laying of tiles will be done with the notch trowel /plier / wedge ,clips of required thickness , levelling system and rubber mallet for placing the tiles gently and easily.
Supply of following fittings and fixtures for PVC doors as specified by Enginners and as directed by EIC.
Alluminuim anodised Tower bolt of size 150 x10 mm
Alluminuim anodised Butt hinges of size 75x63x4mm
Allumunium anodised handle 100 mm with plate 150x32 mm
Oxidised mild steel door latch 250 x20x6 mm
Allumunium anodised slidding door bolt 300x16 mmm
SUPPLY AND INSTALLATION OF MINIMUM 2.5 MTR. DECORATIVE GARDEN POLE WITH THREE ARMS (UPWARD) INCLUDING DECORATIVE GARDEN LIGHT FITTING OF MIN. 20W (LED) , CAST ALUMINIUM, HEXAGONAL SHAPE WITH BASE PLATE AND MOUNTING PLATE, BLACK COLOUR POWDER COATED WITH FLANGE INCLUDING NUT BOLTS FOR MOUNTING. (POLE AND FITTING MUST BE APPROVED BY HAL REPRESENTATIVE PRIOR SUPPLY)
SUPPLY AND INSTALLATION OF MINIMUM 1.5 MTR. DECORATIVE GARDEN POLE WITH DECORATIVE GARDEN LIGHT FITTING(LED) , CAST IRON POLE,WITH BASE PLATE AND MOUNTING PLATE, BLACK COLOUR POWDER COATED WITH FLANGE INCLUDING NUT BOLTS FOR MOUNTING. (POLE AND FITTING MUST BE APPROVED BY HAL REPRESENTATIVE PRIOR SUPPLY)
SUPPLY OF LED FLOOD LIGHT OF MINIMUM 90 WATTAGE, PROTECTION -IP-66, INPUT VOLTAGE 90 TO 300VOLTS,MAKE-BAJAJ/PHILIPS/HAVELLS/SYSKA/CG
INSTALLATION AND CONNECTION OF FLOOD LIGHT
PREPARATION OF FOUNDATION OF M-20 GRADE REINFORCED CEMENT CONCRETE FOUNDATION BY CONSIDERING THE SAFE SOIL BEARING CAPACITY AS 10T/sq.m at 1.5 MTR. DEPTH INCLUDING SUPPLY OF STEEL,CONCRETE, EXCAVATION,FIXING PROVIDED NUT BOLTS WITH THE HELP OF TEMPLATE, DULY PLASTERED AS PER DESIGN COMPLETE FOR 3MTR. TO 4MTR. OCTAGONAL/CONICAL GI POLE
SUPPLY ,LAYING AND TERMINATION OF POLYCAB /FINOLEX /KEI/GLOSTER MAKE 4 CORE X 10 SQ.MM ALUMINIUM CONDUCTOR, 1100VOLTS XLPE INSULATED ARMOURED POWER CABLE, CONFIRMING TO RELEVENT IS STANDARD
SUPPLY , LAYING AND TERMINATION OF POLYCAB / FINOLEX /KEI/GLOSTER MAKE 3 CORE X 1.5SQ.MM COPPER CONDUCTOR,1100VOLTS GRADE, PVC INSULATED FLEXIBLE CABLE, CONFIRMING TO RELEVENT IS STANDARD.
EXCAVATION OF CABLE TRENCH IN ANY TYPE OF SOIL (HARD/SOFT) OF NOMINAL DEPTH 0.5 METER, MAXIMUM WIDTH 0.4 METRE AND LENGTH AS PER SITE REQUIREMENT AND REFILLING THE TRENCH AFTER CABLE LAYING, FINISHING THE SURFACE AND CLEANING THE SITE BY THROWING DEBRIS
PROVIDING (SUPPLY & INSTALLATION) PIPE TYPE EARTHING WITH 40MM DIA. GI PIPE OR 20MM DIA. GI ROD COMPLETE WITH ALL MATERIAL AS PER IS SPECIFICATIONS.
Rupees Fifty Five Lakh Seventy Five Thousand Nine Hundred Twenty Two and Twelve Paise Only
Approximate Basic Amount Put to Tender
Rupees Ten Lakh Three Thousand Six Hundred Sixty Five and Ninety Eight Paise Only
Rupees Sixty Five Lakh Seventy Nine Thousand Five Hundred Eighty Eight and Ten Paise Only
The contractor should visit the site before quoting.
The accumulation of debries is not permitted .It should be removed immediately.
The contractor/Party has to maintain the measurement book.
The quantity mentioned in BOQ is tentative, which may increase or decrease as per site requirement. Payment of bill shall be as per actual measurement.
Contractor will be sole responsibility for the safety of the workers employed by him. Safety helmets, safety belts, any other safety equipments shall be supplied by Contractor without any additional charges. HAL will not be responsible for any accidents/eventuality. Utmost care should be taken while working and no damage should be caused to men, machinery or materials.
Transport arrangement for men / materials will be arranged by contractor at own cost.
Contractor/Party should brief/discuss the work prior to starting the work with monitoring incharge/HAL representative for execution work during contract period.
Contractor / Party should be ready to work during odd hours like Sunday and holidays as per HAL requirement.
Before quoting the rates contractors may visit the site to assess the quantum of work involved.
In case of any dispute, decision of DGM(MAINT & AS) shall be final.
Consumables like cotton waste, cleaning agents will be supplied by contractor.Contractor has to arrange all the tools and tackles to complete the contract work.
Contractor or their authorized representative shall visit HAL whenever called by Engineer-in-charge / HAL representative.
Decorative garden light pole and light fitting must be approved by HAL representtative prior supply.
Vendor must take approval from Monitoring-In-Charge /HAL representataive prior fabrication of feeder pillar.Feeder pillar should be facbricated as per HAL requirement.
During excavation, contractor should take extreme care to avoid damages to existing underground network of cables /pipelines etc.However, if any damage occurs ,it will be contractor's responsibilty to repair & make the system operational.
Electricity required shall be provided by HAL free of cost.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
Etender_notice...pdf
TENDER_DOCUMENT • 0.47 MB
Prequalification_profile.xlsm
TENDER_DOCUMENT • 0.01 MB
Tender_Document.pdf
TENDER_DOCUMENT • 1.63 MB
ECSDetailsForm.PDF
TENDER_DOCUMENT • 0.16 MB
PriceBi_d.xlsm
TENDER_DOCUMENT • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .