Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC V PO RAIKO KI DHANI NAWAJI KA PANA BHURTIYA DISTT BARMER RAJ PIN 344001 | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹19.5 L+₹80,961.50 (4.32%)Rejected-Finance JODHPUR ROAD UTARLAI BARMER RAJ 344035 | BARMER | RAJASTHAN | 344035 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹20.0 L+₹1.3 L (6.92%)Rejected-Finance NEAR RAILWAY STATION UTARLAI BARMER RAJASTHAN PIN 344001 | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹20.0 L+₹1.3 L (6.98%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹22.7 L+₹4.0 L (21.4%)Rejected-Finance 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
15 Nov 2021, 6:00 pmClosed
GE (AF) UTARLAI
GE (AF) UTARLAI, PB NO 11, BARMER 344001 (RAJ)
REPAIRS TO ROOF TREATMENT, FIN, FACIA, CHAJJA, PLASTER PLUMBING AND SANITARY ITEMS IN TECH AREA AT AF STN UTARLAI
2021_MES_482359_1
8230/03/E8 dt 18 Oct 2021
Open Tender
Civil Works
Item Rate
180 days
GE (AF) UTARLAI
As Per NIT
7 documents required · 7 mandatory
₹500
Yes
GE (AF) UTARLAI
₹40,000
Yes
23 Dec 2021
18 Oct 2021
22 Nov 2021
18 Oct 2021
15 Nov 2021
1 Nov 2021
Amount
Taking down cement or cement lime plaster on wall and ceiling including in patches, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
M&L Rendering including in patches, 10 mm thick in cement mortar 1:3 on concrete surfaces,Chajjas in ceiling finished even and smooth without using extra cement complete all as specified.
M & L Preparation of newly plastered ceiling surfaces and applying three coats of white wash. (white wash shall be applied by the brush not by spray gun)
M & L rendering 15mm thick on fair faces or other than fair faces of brick work,concrete or stone masonry surfaces in CM 1:6 finished even & smooth without using extra cement complete all as specified .
M & L Preparation of newly plastered wall surfaces and applying three coats of white wash. (white wash shall be applied by the brush not by spray gun)
M & L Preparation of newly plastered wall surfaces and applying two coats oil bound distemper over a coat of primer complete all as specified. (OBD shall be applied by the brush not by spray gun)
M&L Rough cast plaster as specified .(Rendering coat not less than 10mm thick in C:M 1:3 , while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg size 6 to 12mm mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even)
M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge and complete all as specifeid.
M & L rendering 15mm thick on fair faces of brick work,concrete or stone masonry surfaces in CM 1:4 with using water proofing compound as per manufacturer's instructions and finished even & smooth without using extra cement complete all as specified. Note:- WPC shalll be measured & paid of separately.
M&L Preparing new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete.(Cement base paint shall be applied by the brush not by spray gun)
Supply only integral water proofing compound complete all as specified.
S&F in repairs wire netting of galvanized steel wire 0.91 mm dia fixed with tinned tacks of wire staples size of mesh 20 mm as in chhajas / ceiling plaster repair works complete all as specified.
Dismantling of PCC block/stone masonery built in cement mortar of any specification and in any position complete all as specified.
M&L Pre-cast cement concrete block masonry with solid blocks made of PCC (1:3:6) type C1 using 20mm graded stone aggregate exc 10 cm in width and set in CM 1:6 complete all as specified.
M&L for stone Walling of squared rubble,brought upto coursed, well bonded, bedded and solidly hearted, built in CM 1:6 all as specified.
M&L for stone Walling of squared rubble,brought upto coursed, well bonded, bedded and solidly hearted, built in CM 1:6 but except stone all as specified.
M&L for Extra over stone walling of granite or trap stone for hammer dressing to face stones and dressing of face beds and joints with maximum depression on face from straight edge held against the dressed surface n exc 20 mm to squared rubble walling brought upto coursed complete all as directed.
M & L for PCC (1:4:8) type D-2 using40mm graded stone aggregate in foundation/filling and mass concrete etc complete all as specified.
M&L for providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in coping, kerbs,benching and the like, including weathering slighthy rounded or chamfered angles and throating as directed including necessary form work complete all as specified.
Demolition of reinforced cement concrete of any descrpritpion and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified.
M & L RCC 1:2:4 using 20mm graded stone aggregate as in chajjas, fins, fascias, louvers, parapets and railing etc and the like complete all as specified .
Form work to sides and soffits of beams, chajjas and the like for rough finished surfaces complete all as specified
M&L for mild steel TMT bars 10 mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified.
ditto all as per item above but 8 mm dia complete.
Taking down roof treatment any type any description on top of roof not exc 10cm thick incl removal of rubbish out side MD and complete all as specified.
M&L for PCC 1:2:4 type B0 using 12.5 mm stone aggregate as in roof padding benching kerbs of mud stops, rounded or chamfered on edges incl form work complete all as specified.
M&L screed 15mm thick on RCC roof concrete surfaces in CM 1 : 4 mixed with WPC @ 3 % by the weight of cement and finishing even and smooth without using extra cement complete all as specifeid.
M&L for applying roof treatment on top of roof with APP based polymeric membrane minimum weighing 3 Kg/sqm and minimum 3 mm thick reinforced with polyster non woven fabrick incl a coat of bituminous oil based primer (IS: 3884) @ 250gm/sqm laid on primed surface by torch application including priming complete all as specified
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified.
M&L, Anodised aluminium snap grid with size of grid 605x605mm frame work for false ceiling all as specified (The supporting hanger comprising of mild steel rod, J bolts with necessary bolts, nuts and washers shall be measured and paid for separately) Note:- Steel aluminium sections shall be as per para 10.38 of SSR Part-I.
M&L, Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified (@ 1 x 1 M) complete all as specified.
S&F 4 mm thick HPSC pre-primer non asbestos fibre cement building board (E-classic) decorative finish, fixed to aluminium/ CGI frame work with hold down clips in false ceiling complete all as specified (size 605x605 mm).
Taking up or down steel tubing 15mm bore and connections including for refixing complete all as specified.
S & F 15mm bore 'medium grade' steel tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified .
Fixing only old tubes and connection any grade 15mm bore to walls and ceiling or in floors etc including provision of new fittings as required complete all as specified .
Taking down or up steel tubing 20mm bore and connections fixed/laid in any situation complete all as specified.
S & F 20mm bore 'medium grade' steel tube galvanised with all fittings and fixed complete to walls & ceiling or laid in floor all as specified .
Fixing only old tubes any grade 20mm bore to walls and ceiling or in floors etc including provision of new fittings as required complete all as specified .
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth on stone concrete block or slab wall complete all as specified and directed.
Disconnecting existing tank, setting aside (or lowering if required) for repair,cleaning etc. and hoisting if required reconnecting and refixing in position capacity of tank exc 250ltrs & n exc 500ltr complete all as specified and directed.
Disconnecting existing tank, setting aside (or lowering if required) for repair,cleaning etc. and hoisting if required reconnecting and refixing in position capacity of tank exc 5000ltrs & n exc 1000ltr complete all as specified and directed.
Dismantling water tanks 1000 ltrs capacity complete all as specified.
S&F 1000 litres capacity ISI marked double layered rotational molded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including making inlet/outlet connection complete all as specified.
Dismantling water tanks 500 ltrs capacity .
S & F rotational moulded polyetlene water storage tanks (cylindrical vertical with closed top) 500 ltrs cap hoisted and fixed in position all as specified. Note:- PVC tanks shall be ISI marked & having two layers.
S&F in repairs 20mm bore ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe of following description :-.
S&F in repairs 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed
S&F in repairs 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed
S&F in repair PVC water tank cover with threaded coller suitable for 500 ltrs cap water tank complete all as specified..
S&F in repair PVC water tank cover with threaded coller suitable for 1000 ltrs cap water tank complete all as specified.
M&L for 75 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregae as in water tank platform incl nacessary form work to side of concrete complete all as specified and directed.
Taking down eaves gutter or RWP including fittings of any description complete all as specified & directed by Engr-in-Charge.
S&F PVC (SWR) 110 mm bore pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified.
-ditto- all as per above but 75mm bore
S&F PVC (SWR) 110 mm bore bends any radius complete all as specified.
-ditto- all as per item No 55 above but 75 mm bore
S&F in reparis cast iron floor trap 75mm dia incl jointing to waste pipe fixed in cement concrete type B-1 1:2:4) complete all as specified.
S&F in repairs cast iron Nahani trap 75mm dia incl jointing to waste pipe fixed in cement concrete type B-1 1:2:4) complete all as specified.
S&F in repairs PVC(SWR) floor trap of 75 mm bore, plain with grating including jointing with solvent cement complete all as specified & as directed.
S&F cast iron (spun pipe) soil, waste and vent pipe in any length with or without ears, with cement joints fixed to wall or in floor 100mm bore complete all as specified.
-ditto- all as per Item No 60 above but 75mm bore
S&F cast iron bend ( any radius) dismantling pieces or tappers ( large bore measured) 100mm bore complete all as specified.
-ditto- all as per Item No 62 above but 75 mm bore
S&F in repair cast iron cowl 75mm dia complete all as specified
S&F in repair cast iron cowl 100mm dia complete all as specified
S&F in repair, 15mm bore dia, bib taps, fancy type, chromium plated , cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule pressure fixed to pipe all as specified.
S&F in repairs, fancy type, chromium plated stop valves / angle valve, cast copper alloy with crutch or butterfly handles screwed down high pressure, screwed both ends for 15mm bore iron pipe or brass ferrule complete all as specified and directed.
S & F in repairs 15mm bore stop valve, cast copper alloy, fancy type, chromium plated with long shank and cup ( concealed type ) screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed .
S&F in repairs Pillar tap, cast copper alloy,fancy type, with capstan head, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ wih long screwed shanks and fly nuts, screwed for iron pipe and fixed in repairs, 15 mm bore dia of pipe complete all as specified.
S & F in repairs 20mm bore stop valve, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified .
S & F in repairs Jet spray assembly with all fittingd in EWC as per existing size/ specification all as directed
S & F in repairs swivel shower for PTMT any colour with shower arm 195mm long with bend of 45 degree 15mm dia (minimum weight 80 gms) all as specified.
S & F in repairs PVC connection 15mm size with PTMT nuts of length 450mm all as specified .
S & F in repair Grating doom 125 mm dia with waste hole of PTMT ( Min wt 40 gm) complete all as specified.
S&F in repairs high density polyethylene (LDPE) pipes 40mm bore of presure rating 6kgf/sqq. cm
S & F in repairs stainless steel tubular towel rail 20mm dia 600 mm long complete all as specified and as directed.
S & F vitreous china wash basin, white, flat back, size 550 x 400mm with waste fitting of PTMT32mm bore, and PVC waste pipe and fixing with new brackets including cutting and pinning in ends of brackets complete FIXED IN REPAIR all as specified .
S & F in repairs vitreous China bowl urinal flat back, size 465x355x265 mm ( minimum ) white with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe ) including making good the disturbed surface to match with the existing surface complete all as specified.
S & F repairs vitreous china squatting pan Orrisa pattern size 580mm x 440mm, white, with integral foot rest with CI ‘P’ or ‘S’ trap and fixing in lime concrete (1 lime, 2 sand and 5 aggregate), 150mm thick all round and finished just below level of rim of pan to receive the floor finishing all as specified .
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white, (excludin fixing bolts, flushing cistern and flush pipe) with PVC sheet cover & 'P' OR 'S' trap complete all as specified.
S & F in repairs 10 ltrs PVC valveless syphonic action type, flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of PVC 32mm bore and connection 15mm size 450mm long to WC pan complete all as specified .
Demolition of cement concrete (un reinforced) in floors / pavings, (Below or above gl) and of any description and in any posting not otherwise specifically provided for.
M&L PCC 25 mm thick 1:2:4 type B using 12.5mm graded stone aggregate as in leveling course finished even & smooth complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the permises complete all as specified.
M & L for glazed ceramic coloured tiles 7mm thick 300 x 450mm size in vertical surface, set and jointed in neat cement slurry and pointed in white cement paste pigmented to the laid over 10mm thick cement sand plaster (1:3) finished even & fair and including complete all as specified .
M & L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid, over & including 15mm thick cement sand screed (1:4) finished even & fair complete all as specified .
M& L for 75mm thick PCC 1:3:6 type C-2 (Using 40mm graded crushed stone aggregate) as in plinth protection finished even and fair without using extra cement complete all as specified.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid bedded and pointed in any mortar complete all as specified.
M&L for hard core of broken stone of guage n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified..
M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone agg in sub base flooring complete all as specified.
M&L, for 60mm thick machine pressed precast concrete interlocking paver block, coloured with glossy finish, any shape and size, M- 35 Grade, with grey cement and pigment complete all as specified.
M&L for sand cushioning layer for laying PCC interlocking paver block complete all as specified.
Precast cement concrete Kerb stone 7.5cm thick with PCC 1:2:4, using 20mm graded stone aggregate set in CM (1:6) complete fixed in repair all as specified .
M&L 100 mm thick cement concrete type B-2 (1:2:4) using 40 mm graded stone aggregates including spike rolling to surface or making in pression of expanded metal, while the concrete is green including forming joints.
M&L for forming contraction (dummy) joint 30mmdeepx10mm wide filled with sealing compound(grade 'A') complete all as specified.
Taking down chowkats or frames with shutters without taking off shutters from the frames, area n.exc 1.50 sqm each and removal of hold fast complete all as specified
S & F factory made Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet reinforced with M S square tubes , S&F in opening as per specification & drawing given in SSR-2009.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M S tubes for top & bottom rails M S frame shall be covered with wood grain printed PVC sheet used instead of Plain colour PVC sheet and stile & rails having one side feathered edge and on other side 10mm 90 bent edge having a PVC sheet strip of 20 mm width struck in side with solvent cement for stiles and plain colour PVC sheets 5 mm thick for top rail, lock rail & bottom rail on either side & as gap insert for tap rail & bottom rail, paneling of plain colour PVC sheets to be fitted in the MS frame walded/sealed to the stiles & rails with suitable PVC sheet beading and joined to getger with solvent cement supplying & filling in the frame at site as per specification & drawing given in SSR-2009.
Supply and fixing 100mm long butt hinges 'medium weight' cold rolled mild steel ISI marked complete all as specified.
Supply and fixing 150mm long extruded aluminum handles fabricated type anodized, ISI marked complete all as specified.
S&F aluminium anodised barrel tower bolt of extruded section 150mm long complete all as specified.
M/s godara infratech and power industries
M/S TANUSHREE CONSTRUCTION COMPANY
M.D. CONSTRUCTION CO.
National Rewinding Works
M/S HARIOM CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .