Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.7 LAccepted-AOC | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹20.2 L+₹5.5 L (37.5%)Rejected-Finance | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹24.3 L+₹9.6 L (65.2%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹27.9 L+₹13.2 L (89.7%)Rejected-Finance | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹29.5 L+₹14.8 L (101.1%)Rejected-Finance SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
30 Oct 2023, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
REPAIR / MAINTENANCE OF MCB DB S, SUB MAIN WIRING AND CONNECTED ITEMS AT SUNJUWAN UNDER GE JAMMU
2023_MES_620062_1
GEJC-65/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE Jammu
₹60,000
Yes
14 Nov 2023
5 Oct 2023
1 Nov 2023
5 Oct 2023
30 Oct 2023
18 Oct 2023
Amount
Material and labour for replacement of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement SPN 32 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement of Vertical Distribution Board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and outgoing MCB's and should be IP-43 protected with copper bus bars, neutral links, earthing bar all as specified and directed including taking down old unserviceable DB / MCB any type. Notes: - (i) Rate includes MCCB four pole 125 Amp, 16 KA, 415 volts with adjustable thermal settings. (ii) MCB's shall be measured and paid separately. (iii) TPN DB and MCCB should be of same make.
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size complete all as specified and as directed.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 2.5 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 2.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground earth (in vertical) earth pit not less than 2.25 metre deep below normal ground level with top edge of the earth plate not less than 1.5 metre below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and as directed.
Material and labour in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 Sqmm 2 core complete all as specified and as directed by Engineer-in Charge.
Material and labour in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 6 Sqmm 2 core complete all as specified and as directed by Engineer-in Charge.
Material and labour in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 4 Sqmm 2 core complete all as specified and as directed by Engineer-in Charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep in loose / soft soil and getting out for underground cable / erection of poles, stays etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for sand cushioning for cable with river washed sand and punning to provide required cover as per SSR Part-I complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying bricks common burnt clay sub class 'B' old size for cable protection complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material not exceeding 50 metre away and depositing where directed at a level not exceeding 1.5 metre above from the starting point complete all as specified and as directed by Engineer-in-Charge.
Disconnecting and taking out defective underground cable / service cable any size and any type from trenches, roof, pole, pipe, floor, wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 Sqmm 4.0 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 Sqmm 4.0 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 25 Sqmm 3.5 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 35 Sqmm 3.5 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 Sqmm 2 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 Sqmm 2 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and fixing in replacement MCCB 4 pole, 415 Volt fixed thermal and fixed magnetic setting of capacity 125 Amps 16 KA complete all as specified and as directed.
Supply and fixing in repair MCCB with sheet steel enclosure 415 V, 4 pole, 160 Amps capacity, thermal magnetic, over current settings fixed on walls for electric supply distribution to buildings including necessary connection of cables from LT poles / panels to MCCB's complete all as specified and as directed by Engineer-in-Charge.
Taking down existing serviceable/unsv electric meter alongwith existing angle iron steel box from the wall and refixing electric meter of 3 ph/1 ph in position after repair replacement of MCB TPN box incl replacement of PVC flexible coduit for cable protection complete with making the existing wall neat and clean including patch work, plaster, brick work and white wash as per site requrement.
M/S Sukhmani Construction Co.
Pyramid constructions
Sarbat Construction Co
M/s Sahib Construction and engineers
THAPA TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .