Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80.3 LAccepted-AOC 5TH FLOOR DP 9 P T I BLDG SALT LAKE SALT LAKE KOLKATA WEST BENGAL 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹1.0 Cr+₹21.8 L (27.2%)Rejected-AOC 184 187 TEMPLESTEPS BLOCK ANNASALAI LITTLEMOUNT CHENNAI CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | L2 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹2.4 L
Closing Date
12 Aug 2020, 2:00 pmClosed
SE,KHEC,PWD
SUPERINTENDING ENGINEER (P.W.D) Kolkata Health Electrical Circle KIT Annex Building, 5th FLOOR, KOLKATA 700073
Rep of old lifts in difft MCH under HEC PWDte SITC of 2 No Bed cum 15 Passenger Lift at Gynae Bldg and 1 No Bed cum 15 Passenger Lift at Extension Surgical Bldg1 No Bed 20 Passenger Lift at Rammohan Building after dismantling the old lift in CNMCH
2020_WBPWD_289821_1
WBPWD/SEKHEC/CK/NIQ02/20-21/ 2nd
Open Tender
ELECTRICAL WORKS ORG
Item Rate
540 days
Calcutta National Medical College and Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹2.4 L
Office of the SE,KHEC,PWD
15 Sept 2021
15 Jul 2020
14 Aug 2020
16 Jul 2020
12 Aug 2020
27 Jul 2020
24 Jul 2020
Amount
Gynae Building-Bed-cum-Passenger Lift(G+4)-1 no
Dismantling of old lifts (gear, motor, rail, Collapsiable gate, whole body etc) carefully and shifting to store as per direction of EIC. (Compulsory)
Supplying, Installation, Testing & Commissioning of 15 Passenger Lift (Gynae Building) (Simplex System operation) without Machine Room (Rate to be quoted after inspection & verification of the actual site), Gearless Machine , Stainless steel body with V3F Control Panel with ARD (with Exide maintenance free Battery) and the main following specification. (Make - Otis/ Kone/Schindler) (i) Capacity - 1020 Kg (15 Passenger). (ii) Speed -1.00mps. (iii) No. of stops / openings - 5 stops/ 5 opening ( all openings on the same side ) (iv) Travel height - 17.20 mtrs (approx), Ground floor to 4th floor. (v) Power Supply - 415 V +-5% , 3 Ph., 50 Hz + 3. (vi) Control system - Microprocessor based AC V3F Drive with Full collective Simplex control. (vii) Machine - Permanent Magnet AC Synchronous Motor -Eco-Disc Gearless Drive (viii)Head room existing-4500 mm. (ix) Pit Depth- 1600 mm.
(x) Indicators - (a) Full height Car operating panel with combined luminous micro stroke hall button with 7 segment digital hall position indicator at all landings with up & down arrow.(b) Overload warning indicator in car and COP (7 Segment display ) (xi) Car encloser & Panel - Stainles steel in hair line finish with false ceiling with LED downlighter & fan arrgement (xii) Lift Well/Hoistway available : (2100mm wide X 2900mm deep appx.) (xiii) Car Size (WxDxH) :- 1000 mm Wide x 2400 mm Deep x 2200 mm Height (Rate to be quoted after inspection & verification of the actual site)
(xiv) Car door - Stainless steel SS4 hairline finish centre opening power door (900 mm. X 2000 mm.)(xv) Landing doors - Stainless steel SS4 hairline finish centre opening power door (900 mm. X 2000 mm.)(xvi) Clear door opening - (900 mm X 2000 mm) (xvii) Over Load Protection : Audio & visual indication in car. The lift will not start when over load actuate and door keep open at that time and bypass the landing call when full loaded (xviii) Door Operation : ACV3F operated automatic Centre Opening (COPD) with Multi-Beam full height infrared detector door protection system. (xix) TRACTION MEDIA : Flat Coated Steel Belt with V groove/ Steel Rope, (xx) Fire Rated Door for 60 mins. (Rate should be quoted after inspection and verification of actual & specific site)
(xxi) Emergency light & Emergency alarm - Battery operted emergency alarm and emergency light inside the car. (xxii) Intercommunication System -By pressing the emergency alarm buttom inter cum will work and the attendent shall alarted in need. (xxiii) Ventilation - Cross Flow or 300 mm. sweep fan in car / standard size fan as per I.S specification. (2 Nos.)(xxiv) Car lighting : With 6 nos. LED down lighter as required. (xxv) False ceiling- Stainless steel hair line finish. (xxvi) Car flooring - Granite Matfinish (xxvii)Should provide Fireman Drive with switch - Fireman Switch to be provided at ground floor landing or at main lobby (xxviii) HALL FIXTURES : As per manufacturer design (xxix) HALL FIXTURE FACE PLATE : Stainless Steel #4(Hairline). or Touch sensitive Glass Panel or Seven segment Display. (xxx) HALL BUTTON ARRANGEMENT : As per manufacturer design)
(xxxi) Auto rescue device - Battery oprated automatic rescue device for automatic evacution to the nearest floor in case of power failure. SAFETY FEATURES a) Over Speed Protection b) Single Phase Protection c) Overload Protection d) Phase Faliure Protection e) Terminal Limit Switch f) Emergency Stop Switch g) Interlocking Switch h) Reverse Phase Protection i) Delocking arrangement from landing
Cost for all massonary & fabrication work for installation of Lift & allied accessories, patch modification, temporary or related makeshift arragement regarding lift installation, minor civil work, wall/floor cutting, pocket cutting on wall and mending good the damages properly is to be included.
Gynae Building-Bed-cum-Passenger Lift(G+3)-1 no
Dismantling of old lifts (gear, motor, rail, Collapsiable gate, whole body etc) carefully and shifting to store as per direction of EIC. (Compulsory)
Supplying, Installation, Testing & Commissioning of 20 Bed-cum-Passenger Lift (Gynae Building) (Simplex System operation) with MR/MRL (Rate to be quoted after inspection & verification of the actual site), Geared/Gearless Machine , Stainless steel body with V3F Control Panel with ARD (with Exide maintenance free Battery) and the main following specification. (Make - Otis/ Kone/Schindler) following IS : 14665 (i) Capacity - 1360 Kg (20 Passenger). (ii) Speed -1 mtr per second. (iii) No. of stops / openings - 4 stops/ 4 opening ( all openings on the same side ) (iv) Travel height - 15.38 mtrs (Max), Ground floor to 3rd floor. (v) Power Supply - 415 V +-5% , 3 Ph., 50 Hz + 3. (vi) Control system - Microprocessor based AC V3F Drive with Full collective Simplex control. (vii) Machine - Permanent Magnet AC Synchronous Motor -Eco-Disc Gearless Drive (viii)Head room existing-4728 mm. (ix) Location of Machine room- Top
(x) Indicators - (a) Full height Car operating panel with combined luminous micro stroke hall button with 7 segment digital hall position indicator at all landings with up & down arrow.(b) Overload warning indicator in car and COP (7 Segment display ) (xi) Car enclosure & Panel - Stainles steel in hair line finish with false ceiling with LED downlighter & fan arrgement (xii) Pit Depth : 1600mm. (xiii) Lift Well/Hoistway available : (2200 mm wide X 2950 mm deep appx.) (xiv) Car Size (WxDxH) :- 1300 mm wide X 2400 mm Deep x 2200 mm Height (Rate to be quoted after inspection & verification of the actual site)
(xv) Car door - Stainless steel SS4 hairline finish centre opening power door minimum (1000 mm. X 2000 mm.)(xvi) Landing doors - Stainless steel SS4 hairline finish centre opening power door minimum (1000 mm. X 2000 mm.)(xvii) Clear door opening - minimum(1000 mm X 2000 mm) (xviii) Over Load Protection : Audio & visual indication in car. The lift will not start when over load actuate and door keep open at that time and bypass the landing call when full loaded (xix) Door Operation : ACV3F operated automatic Centre Opening (COPD) with Multi-Beam full height infrared detector door protection system. (xx) TRACTION MEDIA : Flat Coated Steel Belt with V groove/ Steel Rope, (xxi) Fire Rated Door for 60 mins. (Rate should be quoted after inspection and verification of actual & specific site)
(xxii) Emergency light & Emergency alarm - Battery operted emergency alarm and emergency light inside the car. (xxiii) Intercommunication System -By pressing the emergency alarm buttom inter cum will work and the attendent shall alarted in need. (xxiv) Ventilation - Cross Flow or 300 mm. sweep fan in car / standard size fan as per I.S specification. (2 Nos.)(xxv) Car lighting : With 6 nos. LED down lighter as required. (xxvi) False ceiling- Stainless steel hair line finish. (xxvii) Car flooring - Granite Matfinish (xxviii)Should provide Fireman Drive with switch - Fireman Switch to be provided at ground floor landing or at main lobby (xix) Face plate finish - Stainless steel hairline finish.
(xxx) Auto rescue device - Battery oprated automatic rescue device for automatic evacution to the nearest floor in case of power failure. SAFETY FEATURES a) Over Speed Protection b) Single Phase Protection c) Overload Protection d) Phase Faliure Protection e) Terminal Limit Switch f) Emergency Stop Switch g) Interlocking Switch h) Reverse Phase Protection i) Delocking arrangement from landing
Cost for all massonary & fabrication work for installation of Lift machine & allied accessories, patch modification, temporary or related makeshift arragement regarding lift installation, minor civil work, wall/floor cutting, pocket cutting on wall and mending good the damages properly is to be included.
Extension Surgical Building-Bed-cum-Passenger Lift(G+4)-1 no
Dismantling of old lifts (gear, motor, rail, Collapsiable gate, whole body etc) carefully and shifting to store as per direction of EIC. (Compulsory)
Supplying, Installation, Testing & Commissioning of 15 Passenger Lift (Extention Surgical Building) (Simplex System operation) without Machine Room (Rate to be quoted after inspection & verification of the actual site), Gearless Machine , Stainless steel body with V3F Control Panel with ARD (with Exide maintenance free Battery) and the main following specification. (Make - Otis/ Kone/Schindler) (i) Capacity - 1020 Kg (15 Passenger). (ii) Speed -1.00mps. (iii) No. of stops / openings - 5 stops/ 5 opening ( all openings on the same side ) (iv) Travel height - 17.90 mtrs (approx), Ground floor to 4th floor. (v) Power Supply - 415 V +-5% , 3 Ph., 50 Hz + 3. (vi) Control system - Microprocessor based AC V3F Drive with Full collective Simplex control. (vii) Machine - Permanent Magnet AC Synchronous Motor -Eco-Disc Gearless Drive (viii)Head room existing-4500 mm. (ix) Pit Depth- 1600 mm.
(x) Indicators - (a) Full height Car operating panel with combined luminous micro stroke hall button with 7 segment digital hall position indicator at all landings with up & down arrow.(b) Overload warning indicator in car and COP (7 Segment display ) (xi) Car encloser & Panel - Stainles steel in hair line finish with false ceiling with LED downlighter & fan arrgement (xii) Lift Well/Hoistway available : (2040mm wide X 2900mm deep appx.) (xiii) Car Size (WxDxH) :- 1000 mm Wide x 2400 mm Deep x 2200 mm Height (Rate to be quoted after inspection & verification of the actual site)
(xiv) Car door - Stainless steel SS4 hairline finish centre opening power door (900 mm. X 2000 mm.)(xv) Landing doors - Stainless steel SS4 hairline finish centre opening power door (900 mm. X 2000 mm.)(xvi) Clear door opening - (900 mm X 2000 mm) (xvii) Over Load Protection : Audio & visual indication in car. The lift will not start when over load actuate and door keep open at that time and bypass the landing call when full loaded (xviii) Door Operation : ACV3F operated automatic Centre Opening (COPD) with Multi-Beam full height infrared detector door protection system. (xix) TRACTION MEDIA : Flat Coated Steel Belt with V groove/ Steel Rope, (xx) Fire Rated Door for 60 mins. (Rate should be quoted after inspection and verification of actual & specific site)
(xxi) Emergency light & Emergency alarm - Battery operted emergency alarm and emergency light inside the car. (xxii) Intercommunication System -By pressing the emergency alarm buttom inter cum will work and the attendent shall alarted in need. (xxiii) Ventilation - Cross Flow or 300 mm. sweep fan in car / standard size fan as per I.S specification. (2 Nos.)(xxiv) Car lighting : With 6 nos. LED down lighter as required. (xxv) False ceiling- Stainless steel hair line finish. (xxvi) Car flooring - Granite Matfinish (xxvii)Should provide Fireman Drive with switch - Fireman Switch to be provided at ground floor landing or at main lobby (xxviii) HALL FIXTURES : As per manufacturer design (xxix) HALL FIXTURE FACE PLATE : Stainless Steel #4(Hairline). or Touch sensitive Glass Panel or Seven segment Display. (xxx) HALL BUTTON ARRANGEMENT : As per manufacturer design)
(xxxi) Auto rescue device - Battery oprated automatic rescue device for automatic evacution to the nearest floor in case of power failure. SAFETY FEATURES a) Over Speed Protection b) Single Phase Protection c) Overload Protection d) Phase Faliure Protection e) Terminal Limit Switch f) Emergency Stop Switch g) Interlocking Switch h) Reverse Phase Protection i) Delocking arrangement from landing
Cost for all massonary & fabrication work for installation of Lift & allied accessories, patch modification, temporary or related makeshift arragement regarding lift installation, minor civil work, wall/floor cutting, pocket cutting on wall and mending good the damages properly is to be included.
Surgical Building-Bed-cum-Passenger Lift (G+4)-1 no
Dismantling of old lifts (gear, motor, rail, Collapsiable gate, whole body etc) carefully and shifting to store as per direction of EIC. (Compulsory)
Supplying, Installation, Testing & Commissioning of 15 Bed-cum-Passenger Lift (Surgical Building) (Simplex System operation) with MR/MRL (Rate to be quoted after inspection & verification of the actual site), Gearless Machine , Stainless steel body with V3F Control Panel with ARD (with Exide maintenance free Battery) and the main following specification. (Make - Otis/ Kone/Schindler) following IS : 14665 (i) Capacity - 1020 Kg (15 Passenger). (ii) Speed -1 mtr per second. (iii) No. of stops / openings - 5 stops/ 5 opening ( all openings on the same side ) (iv) Travel height - 19.50 mtrs (Max), Ground floor to 4rd floor. (v) Power Supply - 415 V +-5% , 3 Ph., 50 Hz + 3. (vi) Control system - Microprocessor based AC V3F Drive with Full collective Simplex control. (vii) Machine - Permanent Magnet AC Synchronous Motor -Eco-Disc Gearless Drive (viii)Head room existing-4728 mm. (ix) Location of Machine room- Top
(x) Indicators - (a) Full height Car operating panel with combined luminous micro stroke hall button with 7 segment digital hall position indicator at all landings with up & down arrow.(b) Overload warning indicator in car and COP (7 Segment display ) (xi) Car enclosure & Panel - Stainles steel in hair line finish with false ceiling with LED downlighter & fan arrgement (xii) Pit Depth : 1600mm. (xiii) Lift Well/Hoistway available : (1750mm wide X 2900mm deep appx.) (xiv) Car Size (WxDxH) :- 1000 mm wide X 2400 mm Deep x 2200 mm Height (Rate to be quoted after inspection & verification of the actual site)
(xv) Car door - Stainless steel SS4 hairline finish centre opening power door minimum (900 mm. X 2000 mm.)(xvi) Landing doors - Stainless steel SS4 hairline finish centre opening power door minimum (900 mm. X 2000 mm.)(xvii) Clear door opening - minimum(900 mm X 2000 mm) (xviii) Over Load Protection : Audio & visual indication in car. The lift will not start when over load actuate and door keep open at that time and bypass the landing call when full loaded (xix) Door Operation : ACV3F operated automatic Centre Opening COPD /TSPD with Multi- Beam full height infrared detector door protection system. (xx) TRACTION MEDIA : Flat Coated Steel Belt with V groove/ Steel Rope, (xxi) Fire Rated Door for 60 mins. (Rate should be quoted after inspection and verification of actual & specific site)
(xxii) Emergency light & Emergency alarm - Battery operted emergency alarm and emergency light inside the car. (xxiii) Intercommunication System -By pressing the emergency alarm buttom inter cum will work and the attendent shall alarted in need. (xxiv) Ventilation - Cross Flow or 300 mm. sweep fan in car / standard size fan as per I.S specification. (2 Nos.)(xxv) Car lighting : With 6 nos. LED down lighter as required. (xxvi) False ceiling- Stainless steel hair line finish. (xxvii) Car flooring - Granite Matfinish (xxviii)Should provide Fireman Drive with switch - Fireman Switch to be provided at ground floor landing or at main lobby (xix) Face plate finish - Stainless steel hairline finish.
(xxx) Auto rescue device - Battery oprated automatic rescue device for automatic evacution to the nearest floor in case of power failure. SAFETY FEATURES a) Over Speed Protection b) Single Phase Protection c) Overload Protection d) Phase Faliure Protection e) Terminal Limit Switch f) Emergency Stop Switch g) Interlocking Switch h) Reverse Phase Protection i) Delocking arrangement from landing
Cost for all massonary & fabrication work for installation of Lift machine & allied accessories, patch modification, temporary or related makeshift arragement regarding lift installation, minor civil work, wall/floor cutting, pocket cutting on wall and mending good the damages properly is to be included.
Rammohan Building-Bed-cum-Passenger Lift (G+5)-1 no
Dismantling of old lifts (gear, motor, rail, Collapsiable gate, whole body etc) carefully and shifting to store as per direction of EIC. (Compulsory)
Supplying, Installation, Testing & Commissioning of 20 Bed-cum-Passenger Lift (Rammohan Building ) (Simplex System operation) with MR/MRL (Rate to be quoted after inspection & verification of the actual site), Geared/Gearless Machine , Stainless steel body with V3F Control Panel with ARD (with Exide maintenance free Battery) and the main following specification. (Make - Otis/ Kone/Schindler) following IS : 14665 (i) Capacity - 1360 Kg (20 Passenger). (ii) Speed -1 mtr per second. (iii) No. of stops / openings - 6 stops/ 6 opening ( all openings on the same side ) (iv) Travel height - 22.80 mtrs (Max), Ground floor to 3rd floor. (v) Power Supply - 415 V +-5% , 3 Ph., 50 Hz + 3. (vi) Control system - Microprocessor based AC V3F Drive with Full collective Simplex control. (vii) Machine - Permanent Magnet AC Synchronous Motor -Eco-Disc Gearless Drive (viii)Head room existing-4728 mm. (ix) Location of Machine room- Top
(x) Indicators - (a) Full height Car operating panel with combined luminous micro stroke hall button with 7 segment digital hall position indicator at all landings with up & down arrow.(b) Overload warning indicator in car and COP (7 Segment display ) (xi) Car enclosure & Panel - Stainles steel in hair line finish with false ceiling with LED downlighter & fan arrgement (xii) Pit Depth : 1600mm. (xiii) Lift Well/Hoistway available : (2200mm wide X 2950mm deep appx.) (xiv) Car Size (WxDxH) :- 1300 mm wide X 2400 mm Deep x 2200 mm Height (Rate to be quoted after inspection & verification of the actual site)
(xv) Car door - Stainless steel SS4 hairline finish centre opening power door minimum (1000 mm. X 2000 mm.)(xvi) Landing doors - Stainless steel SS4 hairline finish centre opening power door minimum (1000 mm. X 2000 mm.)(xvii) Clear door opening - minimum(1000 mm X 2000 mm) (xviii) Over Load Protection : Audio & visual indication in car. The lift will not start when over load actuate and door keep open at that time and bypass the landing call when full loaded (xix) Door Operation : ACV3F operated automatic Centre Opening (COPD) with Multi-Beam full height infrared detector door protection system. (xx) TRACTION MEDIA : Flat Coated Steel Belt with V groove/ Steel Rope, (xxi) Fire Rated Door for 60 mins. (Rate should be quoted after inspection and verification of actual & specific site)
(xxii) Emergency light & Emergency alarm - Battery operted emergency alarm and emergency light inside the car. (xxiii) Intercommunication System -By pressing the emergency alarm buttom inter cum will work and the attendent shall alarted in need. (xxiv) Ventilation - Cross Flow or 300 mm. sweep fan in car / standard size fan as per I.S specification. (2 Nos.)(xxv) Car lighting : With 6 nos. LED down lighter as required. (xxvi) False ceiling- Stainless steel hair line finish. (xxvii) Car flooring - Granite Matfinish (xxviii)Should provide Fireman Drive with switch - Fireman Switch to be provided at ground floor landing or at main lobby (xix) Face plate finish - Stainless steel hairline finish.
(xxx) Auto rescue device - Battery oprated automatic rescue device for automatic evacution to the nearest floor in case of power failure. SAFETY FEATURES a) Over Speed Protection b) Single Phase Protection c) Overload Protection d) Phase Faliure Protection e) Terminal Limit Switch f) Emergency Stop Switch g) Interlocking Switch h) Reverse Phase Protection i) Delocking arrangement from landing
Cost for all massonary & fabrication work for installation of Lift machine & allied accessories, patch modification, temporary or related makeshift arragement regarding lift installation, minor civil work, wall/floor cutting, pocket cutting on wall and mending good the damages properly is to be included.
Less :- Buy-back the old dismantled lift accessories including motor, gear, control panel, body, rail etc as per direction of EIC.
Terms and condition
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liability period 1 (One) Year
(Rates should be Quoted inclusive of all taxes & duities and L.W.C. @ 1% as applicable)
Otis Elevator Company(India)Limited
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .