Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹29.8 L+₹1,990 (0.07%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹32.9 L+₹3.1 L (10.4%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹33.2 L+₹3.4 L (11.3%)Rejected-AOC 300 STREET NO 10 PREM BASTI SANGRUR PB PUNJAB 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹33.8 L+₹3.9 L (13.2%)Rejected-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
25 Nov 2024, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI-88
REPAIRS TO FLOORING AND CERTAIN MISC WORK AT MD ACCN OF NSD SEWRI AND REPAIRS TO ROOF, FALSE CEILING AND CERTAIN MISC WOKRS AT OTM OF NSD SEWRI UNDER GE (NW) MANKHURD
2024_MES_681707_1
8400/E8
Open Tender
Civil Works
Item Rate
300 days
GE (NW) MANKHURD
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
Yes
GE (NW) MANKHURD
₹90,000
Yes
22 Jan 2025
28 Oct 2024
27 Nov 2024
29 Oct 2024
25 Nov 2024
11 Nov 2024
Amount
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing Vitrified Coloured Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to recive tiles/stone slabs complete all as specified and directed by EIC.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing coloured Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with nthe colour of tiles, over and including 15mm thick cement mortar screed bed in CM 1:6, complete all as specified and directed.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing coloured 450x300x6mm thick glazed ceramic tiles on vertical surfaces such as skirting,dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with the colour of tiles, over and including 10mm thick cement mortar backing coat in CM 1:4, complete all as specified and directed.
S&F in repairs vitreous coloured China Europeon water closet (Pedestal Pattern) including 10 ltr capacity low level flushing cistern with necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete. Jaquar Essco Model No of EWC - ECS-WHT-551SNPP183LZ or ECS-WHT-551PNPP183LZ
S&F in repairs vitreous China wash basin white, flat back size 550 x 400mm including 15mm dia fancy type pillar tap of Make ESSCO Model no DLX-507KN or equivalent of make Parko as approved by the GE, , chromium plated CP waste coupling, chain and plug, waste fitting, union and waste pipe 32mm dia of required length and all necessary 450mm long outlet and inlet PVC connections pipes with PTMT check nuts complete.
S&F in repairs vitreous China squatting pan (Orissa pattern), white, of size 580x440mm white, with 'P' or 'S' trap, integral foot rests including flush pipe, trap, lime concrete bedding inlcuding taking out of old lime concrete bedding, unserviceable connections etc and connecting up new complete all as specified and directed by the Engineer-in-charge
S&F in repairs vitreous china urinal half stall type (back or corner wall type ), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement with discharge pipe etc complete all as specified and as directed by Engineer In Charge.
Labour for cleaning /clearing of blockage of gully traps, floor traps, vertical and horizontal soils/ waste pipe of different dia and sewage lines( PVC/SGW/ CI/RCC of any dia) except cleaning of manholes including opening inspection eye door of bend/ branch pieces, rodding till smooth flow and refixing of door after cleaning and any other cleaning work as directed by Engr-in-charge in the concerned area of the contract under GE (NW) Mankhurd Note: (a) Contractor's labour will report daily at 0845 hrs on all working days at online complaint cell centre and attend complaints given by Engr -In- Charge . Complaints needs to be cleared within 24 hrs after receiving the complaints . The contractor will deploy requisite labour and supply all T&P ( mechanical Iron rods, knot ropes , bamboo etc) scaffolding ladders and necessary safety measures such as gas mask, use of safety belt and cell torch etc and any other materials required to clear the blockages at the site without any extra cost . In case any labour does not report to Engineer In Charge for the whole day or found missing more than half an hour on any day, Panel recovery @ RS.860/- per head per day shall be made proportionally from contractor's dues. b) The above item includes conveyance cost of labour with their tools to travel from one area/location to other area/location to attend complaints, plugging of sewer and diverting flow of sewage if necessary to carry out the work and removal of sludge from the site to outside MOD land (The department shall not be liable to provide any kind/form of transportation to the labour). (c) Registers of labour attendance and complaints shall be maintained by contractor at their own cost,which shall be kept in the custody of MES Department(complaint cell) duly signed by contractor's representative ,JE(civil) and Engineer in charge.
Taking down chowkats or frames, not exc 2 Sqm each with wooden/ flush/ PVC /aluminium shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and providing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). including providing Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant.WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall beacceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. WPC frame should be matching with shutter and any type of laminate approved by accepting officer is deemed to be included in the qouted rate Size of shutter for each frame will only be considered for mode of measurement.
Taking down chowkats or frames, not exc 4 Sqm each with wooden/ flush/ PVC /aluminium shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and providing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). including providing Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant.WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. WPC frame should be matching with shutter and any type of laminate approved by accepting officer is deemed to be included in the qouted rate Size of shutter for each frame will only be considered for mode of measurement.
Taking down chowkats or frames, not exc 4 Sqm each with wooden/ flush/ PVC /aluminium shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and also taking down of grills (where exists), complete all as specified and directed and S&F standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame, shutters for doors, window / ventilators, partitions, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing etc complete all as specified and directed (Aluminium section shall be of make Jindal/Hindalco/ Indalco) Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer, whichever is less, shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and wire cloth shall be measured and paid separately as supply only under respective items.
S&Faluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy and fixedd nuts, four on bolt plate and two on staple plate and fixed,300mm complete. fixed in repairs
S&F aluminium, anodised, barrel tower bolts of extruded section and fixed 150 mm fixed in repairs
S&F Stainless butt hinges with brass screws, size 100mm fixed in repairs
S&F extruded aluminium alloy handles, fabricated type., anodised,150 mm fixed in repairs
M&L for Cement concrete in C1 type (1:3:6) using 20mm graded stone aggregate as in plinth protection and finished even and smooth with using extra cement.
M&L Precast cement concrete cover slabs 75mm thick and Crossectional area exc 0.36 Sqm and n.exc 0.5 Sqm each for drain cover and similar work with plain faces set in cement mortar 1:6 complete all as speicified and directed.
S & F in repairs Soap dish, vitreous China white, approximate size 160x 160x90mm fixed to chromium plated brass screws
S&F aluminium, anodised, barrel tower bolts of extruded section and fixed 150 mm fixed in repairs
S&F aluminium, anodised, barrel tower bolts of extruded section and fixed 100 mm fixed in repairs
S&Faluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy and fixedd nuts, four on bolt plate and two on staple plate and fixed,250mm complete. fixed in repairs
S&Faluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy and fixedd nuts, four on bolt plate and two on staple plate and fixed,300mm complete. fixed in repairs
S&F butt hinges, Stainless steel butt hinges of size 100mm fixed in repairs
S&Fbutt hinges, Stainless steel butt hinges of size 75mm fixed in repairs
S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples,fixed in repair
Supply only stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
Returning, filling including spreading, leveling watering and well ramming in layers n.exc 25cm in hard/dense soil complete all as specified and directed by Engr-in-Charge..
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M & L for plain cement concrete 1:3:6 type C2 (using 40mm graded agg) as in bed to drain pipe, 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested including necessary shuttering and supports to concrete
M&L for Reinforced concrete pipes, class NP2, laid and jointed complete with collars 150 mm dia
Cleaning manhole of size n.exc 1.50 Sqm by taking out sludge in semi liquid/solid stage (incl. all water etc) from inside of manhole of depth not exceeding 1.5 m and removing the sludge to a distance not exceeding 50m depositing in trenches including supply and sprinkling bleaching powder and covering sludge with earth to a thickness not less than 30 cm including all earth work, returning filling, removal of surplus soil & necessary temporary cleaning and necessary safety measures such as gas mask, use of safety belt etc as directed by the Engineer-in-Charge.
Opening cover of manhole/septic tank exc 1.5 m depth, dewatering and pumping out night sludge etc from septic tank by mechanical means and removing sludge outside MD land and cleaning the septic tank as per BMC rules and placing the cover in original position taking all precautionary and safety measures all as directed. Note: All T&P and transportation for carrying sludge shall be provided by the contractor at their own cost.
M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified
M&L for 15mm thick rendering (10+5mm) consisting of 5mm thick in CM 1:4 with water proofing compound (water proofing compound shall be used as per manufacturers instructions) over a coat of 10mm thick in CM 1:6 over brick or concrete surfaces finished even and fair.
M & L for cement concrete 1:2:4 , type B-1 (using 20mm graded stone aggregate) as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like in surface benching including weathering, slightly rounded or chamfered angles and throating, as directed including necessary form work.
M & L for precast reinforced cement concrete 1:2:4 type B-1(20mm graded agg) as in cover slab for manholes/drainage etc, set in cm 1:6 including necessary form work all as specified and directed. (Note :- Reinforcement shall be measured and paid separately).
S & F for CRS TMT bars 10 mm dia and over, cut to length, bent to shape required including mild steel wire (annealed) not less than 0.9mm dia complete all as specified.
Supply only intergal water proofing compound. (ISI marked).
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 100/150 mm dia pipe
M & L for PCC type C2 1:3:6 using 40 mm graded aggregate as in foundation, filling and mass concrete
Removal of plant growth from wall/roof projection or along the soil /rain water down pipe at any level by injection with chemical Glyphospate solution (4% concentration) of 20ml or till refuse by cutting or injection in stem of plants or roots at 20m including scafolding upto any height.
M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting CM 1:6 in mortar ,Type C1,1:3:6,(20mm graded aggregate) complete all as specified and directed.
Mild steel work such as rungs,handles
Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement incl forms,moulds,mitred/stopped ends.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge.
M&L broken stone or boulders hardcore of gauge n.exc 63mm, deposited, spread and levelled and well rammed in layers n exc. 15 cm thick, watered and rammed to a true surface.
M&L for PCC 1:3:6 type C-2 75 mm thick (using 40mm graded aggregate) as in sub base complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block made with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.
M&L for Sand Cushoining of average thickness 30mm after consolidation set and laid to level the interlocking tiles
M & L for PCC 1:4:8 type D2 using 40mm graded stone aggrigate as in foundation filling.
M&L rendering 15 mm thick on fair faces of brick surfaces in CM(1:6) finished even and fair
Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
S&F in repairs for 300mm dia reinforcement concrete pipes, class NP 3, laid and jointed complete with collars.
M&L for Concrete bed in Cement concrete with 1:3:6 type C-2 to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested; in completely all as specified and as directed.
M&L for Complete removal of existing treatment and preparation of plastered surfaces on walls, preparation for Acrylic emulsion and applying applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces
M&L for preparation of old plastered surfaces on walls, preparation for Acrylic emulsion and applying applying one coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces
M & L for preparation of old surfaces for applying one coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm
M&L for complete removal of existing treatment by washing, rubbing down and stopping of old decorated surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and levelling with minimum 1 mm thick white cement based wall care putty for obtaining plain surface complete all as specified and directed.
M & L for preparation of old distempering surfaces including stopping of nails holes,cracks etc. and applying one coat of oil bound distemper on wall complete all as specified.
Preparation of old surfaces on ceiling (plastered or unplastered or previously white washed) and applying one coat of white wash complete all as specified.
Preparation of old surfaces on wall (plastered or unplastered or previously white washed) and applying one coat of white wash complete all as specified.
M & L for preparation of old wooden surfaces of any description over 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
M&L for PVC (SWR) pipes fixed in repairs single socketed in any length with rubber ring joints laid in trenches or floors 110 dia.
M&L for PVC (SWR) pipes fixed in repairs single socketed in any length with rubber ring joints laid in trenches or floors but 75mm dia
M&L PVC (SWR) pipes fixed in repairs single socketed in any length with rafter joints fixed to wall of 110mm dia
M&L PVC (SWR) pipes fixed in repairs single socketed in any length with rafter joints fixed to wall of 75mm dia
S&F 110mm bore PVC (SWR) branch piece single (Single Y ) equal or unequal with access door
S&F 75mm bore PVC (SWR) branch piece single (Single Y ) equal or unequal with access door
S&F 110mm bore PVC (SWR) bend with access door
S&F 75mm bore PVC (SWR) bend with access door
M&L PVC (SWR) Junction single, fixed in repairs (Single T) equal or unequal of 110mm dia bore provided with access door
M&L PVC (SWR) Junction single, fixed in repairs (Single T) equal or unequal of 75mm dia bore provided with access door
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm and Supply & fixing 15 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm and Supply & fixing 20 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 25mm and Supply & fixing 25 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F Unplasticised PVC pipes of 15mm bore of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe
S&F in repairs 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, of suitable length as per site requirement connecting to WC etc, and connections to pipes and fixing of chain and pull, or lever, if any complete all as specified and directed.
M&L for forming V grooves in plaster n exc 5 mm deep and n exc 5 mm on face and filling cracks with crack X paste of M/s Dr fixit or with eequivalent of M/s STP Ltd including necessary scaffolding complete all as specified.
M&L for forming V grooves in plaster exc 5 mm deep and exc 5 mm on face and filling cracks with cement mixed with M/s Dr fixit or equivalent of M/s STP Ltd including necessary scaffolding complete all as specified.
M&L for fixed in repairs 15 mm dia Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified , Cat No 187 of Prayag or equivalent make as approved by the GE complete all as speicified
S&F fixed in repairs Two way Bib cock with flange 15mm dia Model no DLX-512ANKN of ESSCO or equivalent of MarC ,Parko as approved by the GE complete all as specified and directed.
S&F fixed in repairs 15mm bore brass CP Stop Cock, Make ESSCO Model no DLX-526NKN or equivalent of make Parko as approved by the GE, complete all as specified and directed.
S&F fixed in repairs 15mm bore brass CP Bib Tap, Make ESSCO Model no DLX-511KN or equivalent of make parko as approved by the GE, complete all as specified and directed.
S&F fixed in repairs 15mm bore brass CP Pillar cock 15mm dia Model no DLX-507KN or equivalent of make parko as approved by the GE, complete all as specified and directed.
S&F in repairs floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring of length 140mm fixed in floor etc complete all as specified and directed.
S&F in repairs aluminium (Die cast body) hydraulically Door closer regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg all as specified and directed.
Demolition of cement concrete in any description or in any position (below or above ground level).
M & L for 75mm thick cement concrete 1:3:6, type C -2 as in plinth protection and PCC path, finished the suface even & smooth without using extra cement including necessary form work finishing exposed edges fair complete all as specified.
Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc.
M & L for brick work with subclass 'B' bricks straight or curved on plan exceeding 6mtr mean radius built in CM 1:6 complete all as specified.
M&L for plain cement concrete 1:3:6 (type C2), using 40mm graded stone aggregates mixed with water proofing compound @3% by weight of cement for fixing of nahani or floor traps, bedding in manholes, sunken floor complete all as specified and directed by the Engineer-in-charge Note: Water proofing compound shall be measured and paid separately
M&L for 15mm thick rendering (10+5mm) consisting of 5mm thick in CM 1:4 with water proofing compound (water proofing compound shall be used as per manufacturers instructions) over a coat of 10mm thick in CM 1:6 over brick or concrete surfaces finished even and fair.
M&L for 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement including removing the old one etc complete all as specified and directed.
S & F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified.
M & L for aluminium anodised suspended false ceiling fixed in repairs in the panels of size consisiting of 600x600 mm lay in tiles 8 mm thick with PVC lamination on the face side and metalized polyester film on backside as granular pattern of saint gobain/Armstrong/equivalent; with aluminium anodised angle 30 x30 x 2 mm fixed along the wall and main and cross tees of size 31.75 x 31.75 x 1.6 mm screwed along side of walls fixed with wooden plugs and hanging from existing slab/ steel truss including 6 mm dia GI wire suspended adjustable level from rafter purlins(length as per site requirement) including complete all as directed by Engineer-in-charge. Note : The contractor's quoted rates shall also be deemed to include for making/ cutting opening in the ceiling of the required size and shape for fixing light fitting, cat walk and provision of neccesary scaffolding for complete work at maximum height of 8mtrs etc, complete all as directed.
M&L for structural repairs to Columns,beams and slabs and chajja at maximum height of 8mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3)M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces
M&L for structural repairs to Columns,beams and slabs and chajja at maximum height of 8mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3)M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 10mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on new surfaces of walls etc, finished even and smooth, complete all as specified and directed.
M&L for structural repairs to Columns,beams and slabs and chajja at maximum height of 8mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3)M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 5mm thick polymer modified ready mix cement based plaster on the ceiling surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including Preparation of new plastered surfaces and applying three coat of white wash complete all as specified.
Providing and fixing additional steel bar in various structural elements like column ,beams and Slab etc. including drilling ,bending and fixing the bars tying with preleft binding wires etc.
S&F in repairs Pre-painted Corrugated galvalume sheet having aluminium zinc coating with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc. completely all as specified and as directed. upto maximum height of 6 Mtr
S&F in repairs Pre-painted Plain galvalume sheet having aluminium zinc coating with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc. completely all as specified and as directed. upto maximum height of 5 Mtr
S & F in repairs Steel work in tubular /Rectangular hollow section in trusses, Posts, Purlins, Rafters etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240
S & F in repairs Steel work Fe 410 F23-W (Gde- E- 250) quality-A in plates or gusset plates to truss all as specified and directed
M&L for Providing waterproofing treatment as specified below and at any height of roof surface including removal of watertank, plumbing line during waterproofing making good if any holes and refixing the same as directed by Accepting officer and Engineer in charge complete 1) Dismantling completely existing roof treatment (excluding cement screed bed ) including loosened cement plaster and exposing the top surface of RCC slab and making good the same in CM 1:4 and removing rubbish, etc outside MD land complete all as specified and directed by the Engineer-in-charge 2) M&L for averaging 50 mm thick PCC 1:2:4, type -B-1, using 20mm graded stone aggregated as in padding concrete of roof mixed with WPC in the proportion as recommanded by the manufacturer(s), complete all as specified and directed, 3) M&L 10 mm thick Screed bed or bedding layer in CM (1:3) with WPC when the concrete is still green complete all as specified and directed. 4) M & L for APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a). The roof surface shall be throughly wire brushed cleaned to eliminate all sharp projection, washed dried upto and cleaned overall foreign material and dust to receive primer. (b). The dry surface shall be primed with Torch shield primer as per manufacturer’s instructions, manufactured by the same agency as that of APP membrane. (c). Providing and laying APP modified polyester reinforced water proofing membrane with minimum weight of 3.5 Kg/Sqm, as specified here-in-before. (d). The APP membrane shall be laid using torch-on butane application with minimum 10 cm side overlap and 15 cm end overlap. The laying of membrane shall be got done through an authorised applicator of manufacturer of the membrane. (e). The APP membrane shall be taken up to minimum 200 mm on vertical surfaces. The edge of the membrane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant.
S&F in repairs aluminium anodised Grills of approved design for window / Bolcony ventilators and fixing with F/U channel for window, ventilators, balcony openging in architectual or rectangular type in existing building with C.P. brass/ stainless steel screws @ 200 mm centre to centre, , including drilling as required in RCC sections, complete all as specified and directed. Note: The Grills shall be of Model DG-102/DG-104 of Make Deco or equivalent make as approved by the GE.
M&L for 4.8mm thick Sheet glass, ordinary quality and glazing with oil putty/rubber beading in square/rectangular size as required in each pane for Partition/Door/Window/Ventilator and similar works etc.
S&F in repairs brass chromium plated, shower rose, 125mm size with and including 195mm long 15mm bore brass chromium plated shower arm with bend of 45 degree, complete all as specified and directed.
S&F for PVC (SWR) multi floor trap 75mm dia with grating including jointing with solvent cement
Supplying and laying in repairs against any dia GI tubing of 16mm Outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified, complete all as specified and as directed.
Supplying and laying in repairs against any dia GI tubing of 20mm Outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified, complete all as specified and as directed.
Preparation of old surfaces on walls (plastered or unplastered or previously distempered ) and applying one coat of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. complete all as specified.
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm including exterior wall care putty over new surfaces Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 10mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on new surfaces of walls etc, finished even and smooth, complete all as specified and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement
Taking down cement or cement lime plaster on concrete surfaces etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 5mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour Preparation of new plastered surfaces on ceiling and applying three coat of white wash complete all as specified. and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement Note : A sum of Rs 37,493.00 towards sch of credit shall be deducated to arrive the contract sum.
Atharva Enterprises (BID ID -3172885)
AM ENTERPRISES (BID ID -3168172)
KRISHNA ENGINEERS (BID ID -3168291)
mp construction co (BID ID -3173925)
Parmatma Enterprises (BID ID -3167016)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .