Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAccepted-AOC NEAR GOVT HIGHER SECONDARY SCHOOL NO 1 MALL ROAD MORAR GWALIOR 474006 M P | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L1 | Accepted-AOC Being a lowest | |
| 2 | L2₹45.0 L+₹97,975 (2.23%)Rejected-Finance | L2 | Rejected-Finance Not a lowest tender | |
| 3 | L3₹45.7 L+₹1.7 L (3.95%)Rejected-Finance | L3 | Rejected-Finance Not a lowest tender | |
| 4 | L4₹46.4 L+₹2.4 L (5.46%)Rejected-Finance NAKA CHANDRA WADANI NAHARWALI MATA ROAD LASHKAR GWALIOR MP | GWALIOR | GWALIOR | MP | L4 | Rejected-Finance Not a lowest tender | |
| 5 | L5₹46.5 L+₹2.5 L (5.62%)Rejected-Finance TOMAR BUILDING R K PURI THATIPUR GWALIOR 474006 MP | GWALIOR | GWALIOR | MP | 474006 | L5 | Rejected-Finance Not a lowest tender |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
30 May 2023, 6:00 pmClosed
GE AF TA Gwalior
GE AF TA Gwalior 474020
REPAIR/MAINT OF RCC CHAJJA, FACIA, ROOF TREATMENT, EXTERNAL PERIODICAL AND MISC REPAIR WORKS AT AF STN GWALIOR
2023_MES_591701_1
8900/1482/GWL/E8
Open Tender
Civil Works
Item Rate
330 days
AF STN Gwalior
As per tender documents
8 documents required · 8 mandatory
₹500
GE AF TA Gwalior
₹90,000
Yes
22 Jun 2023
27 Apr 2023
7 Jun 2023
27 Apr 2023
30 May 2023
16 May 2023
Amount
Demolition of brick work or stone masonry of any description and in any position built in cement mortar including all quoins, arches pillar etc including disposal of rubbish complete all as specified and directed.
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 M mean radius built in CM (1:6) complete all as specified and directed.
All as per item No 2 here-in-before but, except brick using old retrieved bricks obtained from demolition in serviceable conditions complete all as specified and directed.
M&L in repair for 15mm thick rendering fare face of brickwork or concrete surfaces in CM 1:4 finished even and smooth (without using exrtra cement)etc complete all as specified and directed.
M&L in repair for 15mm thick rendering other than fare face of brickwork or concrete surfaces in CM 1:6 finished even and smooth (without using exrtra cement)etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M & L for PCC (1:2:4) type B0, using 12.5mm graded stone aggregate as in cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs including necessary form work complete all as specified and directed by Engr-in-Charge.
Demollition of cement concrete ( reinforced) of any description and in any position not otherwise specifically provided for complete all as specifeid and directed.
M&L for RCC (1:2:4) type B1 (using 20mm graded aggregate) as in shelves, chajja , etc including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
M&L for RCC (1:2:4) type B1 (using 20mm graded aggregate) as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like for etc including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
M&L for RCC (1:2:4) type B1 (using 20mm graded aggregate) as in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
M&L for RCC (1:2:4) type B1 (using 20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
M&L for RCC (1:2:4) type B1 (using 20mm graded aggregate) as in Columns, pillars, piers, posts including necessary form work complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately)
S&F mild steel TMT bars of 10 mm dia and over cut to length, bent to shape as required including cranking, bending, spirally for hooping for column hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia for securing with clips complete all as specified and directed.
Same as per item No above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M & L for repairing of damaged RCC Chajja, fascia, fins, roof projection, ceiling and balcony railing etc at any height upto 10.00 M by rendering 10 to 30mm thick in one or two layers as per site requirement in CM 1:3 incl hacking out old broken/damaged concrete portion, cleaning of old reinforce etc and applying neat cemtnt slurry @ 3 Kg/Sqm complete all as specified and directed. (Note : rate for all scaffolding required for repairing work shall be deemed included in this rate)
M&L for Providing, cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edges and padding over roof surfaces etc complete all as specified and as directed.
M&L for Cement concrete tiles 20cm x 20cmx 20mm thick, machine pressed; set jointed and pointed in neat cement slurry in roofs, and pointed in neat cement slurry with grey cement and no pigment over 15mm thick screed bed in CM 1:4 including dismentling of existing tiles with screed without disturbing the roof treatment/ bitumenous felt complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
M & L for 10 mm thick screed bed in cement mortar 1:4 mixed with using liquid water proofing compound as per manufacturers instructions (Note:Water proofing compound shall be measured and paid seprerately under respective item of "BoQ") over roof top surface finished even and smooth using extra cement and application of water proofing treatment using APP modified roof membrane over existing RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying bitumen primer @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Applying hot blown grade bituminen 85/25 @ 1.2 Kg/Sq M over primer. (d) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap by aithorized applicators. Make: IWL India Ltd / STP / Pidilite Industics Ltd etc
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M&L for glazed ceramic Coloured tiles in vertical surface 350x 250x 7mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering on fair faces of brick work or concrete surface in cement moratar 1:4 complete all as specified and directed.
Demollition of cement concrete ( unreinforced) including floor tile ground floors and pavings n. exc 15 cm thick below or above G.L complete all as specified and directed .
M&L for 25 mm thick PCC (1:2:4) type B0 (12.5 mm graded stone agg) as in sub base of flooring complete all as specified and directed.
M&L for non skid joint free coloured ceramic tiles 7-8mm thick (Square/Rectangular), area of each tiles exc 0.11 Sqm but not exc 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles over 15 mm thick screed bed or bedding in layer of mortar for laying floor finishes in cement plaster 1:4 complete all as specified and directed.
M&L Double charged Virified Ceramic tiles 8-10 mm thick (square/rectangular) polished, area of each tiles n exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match light shade incl 15mm thick screed bed in CM 1:4. complete
M&L Double charged Virified Ceramic tiles 8-10 mm thick (square/rectangular) polished, area of each tiles n exceeding 0.36 sqm, in skirting/dado or vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match light shade incl 10mm thick Rendering in CM 1:4. complete all as specified
S&F in repairs 150mm dia PVC (SWR) pipes single socketed in any length at any height with rubber ring joints fixed to walls/ hanger cladding with necessary brackets including tee and bends.
M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including Dismentling of existing Plain or corrugated steel /AC Sheet complete all as specified and directed.
M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, Ridge, valley/ gutter fixed with self tapping screws including Dismentling of existing Plain or corrugated steel /AC Sheet complete all as specified and directed.
M&L for 5-30mm thick rendering on concrete surfaces as in celinig in CM 1:3 finished even and smooth without using extra cement incl Hard drawn steel wire fabric wt n exc 4kg per sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt after cleaning reinforcement by anti corrosive chemical incl taking down cement plaster on concrete surface incl preparation of newly plastered surface and applying three coats of white wash complete all as specified and directed.
M&L for 15mm thick rendering fare face of brick/stone masonry walls in CM 1:4 finished even and smooth (without using exrtra cement) including taking down cement plaster on brick surface or stone including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
S&F in repairs 5mm thick tinted glass fixed with necessary rubber gasket and aluminium snap beadings tint match with existing complete all as specified and directed.
Supply and fix in repairs 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n.exe 0.50 Sqm in each pane complete.
M&L for Preparation of old decorated surfaces of wall including cornices, by brooming down or steel wire brushing to remove dust, dirt and loose scales of lime wash and other foreign material, scrapping down, smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including filling the cracks and depressions with putty and applying one coat of white wash by the use of rollers complete all as specified and directed.
Ditto as per item No 35 above but one coat of white wash on ceiling surface complete all as specified and directed.
Ditto as per item No 35 above but one coat of distemper oil emulsion on ceiling surface complete all as specified and directed.
M&L for Preparing old decorated plastered or unplastered surfaces of external walls and applying one coats exterior weather proof Paint by the use of rollers including filling cracks/depressions with putty to make the adjacent surface even and smooth complete all as specified and directed. [Make:-'APEX' of M/s Asian Paints or equivalent in M/s Berger as approved by GE].
M&L for Preparing old painted surfaces of wood and wood based materials of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Preparing old painted steel & iron surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Preparing old painted steel & iron surfaces of any description n.exc 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers and and applying a coat with putty to make the surface even and smooth matching to the adjacent wall surfaces and applying two coats distemper oil emulsion by the use of rollers, over a coat of primer all as specified and directed.
M&L for preparation of surfaces of wood and wood based materials of any description, width or girth including cleaning and a coat of wood filler on old works and applying french polish in one or more coats to the required texure and glossy finish complete all as specified and directed.
M&L for Preparing old decorated plastered or unplastered surfaces of walls including filling the cracks, depressions with puyty to match with the adjacent surface and applying one coat of plastic emulsion paint, white or tinted by the use of rollers as approved complete all as specified and directed.
M&L for prepration of old decorated Brick tile /Concrete tiles (Chequered / interlocking tiles) cleaning by any means, and applying one coat of floor tile paint any colour with spray gun/compressor complete all as specified and directed as approved by Engr-in-Charge. Make: INDOGO Floor Paints or Apex Floor Guard of Asian Paints
M&L for complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, and applying two coat of Texture paint over a coat of primer of any colour complete all as specified and directed.
M&L for preparation of old painted surface and applying one coats of aluminium paint on steel surface of any description over 10cm in width or girth completed all as specified and directed.
M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, and filling the cracks and depressions with putty/ chalk whitening to make the surface even and smooth matching to the adjacent wall surfaces and applying two coats exterior weather proof Paint (Make : APEX of Asian Paints or equivalent in Berger Paints etc), by the use of rollers over a coat of primer white or tinted as approved complete all as specified and directed.
M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, and filling the cracks and depressions with putty/ chalk whitening to make the surface even and smooth matching to the adjacent wall surfaces applying two coat of external emulsion paint/weather coat, in camouflaging pattern on CCD scheme (Pattern as approved by GE) by the use of rollers on surfaces of any type of building, wall, any surfaces, any height, Over a coat of primer complete all as specified and directed. Note- Rate quoted by contractor incl scaffolding and T&P upto 15m height of the building. No extra payment admissible on this account. (Make : Apex of Asian Paints or equivalent in Berger Paints etc)
M&L for applying one coat of external emulsion paint/weather coat, in camouflaging pattern on CCD scheme (Pattern as approved by GE) by the use of rollers on surfaces of any type of building, wall, any surfaces, any height, incl preparation of old decorated surfaces complete all as specified and directed. Note- Rate quoted by contractor incl scaffolding and T&P upto 15m height of the building. No extra payment admissible on this account. (Make : Apex of Asian Paints or equivalent in Berger Paints etc)
M&L for Preparation of newly Plastered surfaces and applying two coats of white wash complete all as specified and directed.
M&L for Preparation of newly plastered surface and applying two coat of weather coat exterior emultion (Make : ACE of Asian Paints or equivalent in Berger Paints etc) white or tinted by the use of rollers over a coat of primer as approved complete all as specified and directed.
M&L for Preparation of newly plastered surface and applying two coat of distemper oil emulsion white or tinted by the use of rollers over a coat of calk whiening primer (preparatory to distempering) as approved complete all as specified and directed.
M&L for clean the surface with wire brush, removal of loose material, any damage portion, and removal of existing china mosiac/ tarfelt, wash the surface, fill the cracks if any by using single component high elongation moisture triggered PU sealent (Make-Dymonic 100 or equivalant as approved by GE) then coat the entire surface with moisture triggered polyurethane quoting of water proofing chemical (Make- Tremproof 250 GC/ Tremproof 201/60 or equivalant as approved by GE) at a thickness of 1mm and curing the prepared surface for specified duration complete all as specified and directed.
M&L for Preparation of treated surface of roof and applying one coat of aluminium paint complete all as specified and directed.
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm FRLS of voltage rating 1100 Volts drawn in and including surface PVC conduit of dia not less than 20mm/ casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. Make :- Havells/KEI/Anchor
All as per item No 56 here-in-before but cable of size 6 Sqmm FRLS with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. (Note : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit Make :- Havells/KEI/Anchor
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (Green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit Make :- Havells/KEI/Anchor
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm, FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit. Make :- Havells/KEI/Anchor
M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 16 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in and including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 16 Sqmm as earth continuity conductor complete all as specified and directed. (NOTE: Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.) Make :- Havells/KEI/Anchor
M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in and including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor complete all as specified and directed. (NOTE: Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.) Make :- Havells/KEI/Anchor
M&L for sub main wiring in replacement using four single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in and including recessed PVC conduit of dia not less than 32mm with standard accessories, along-with two run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. (NOTE: Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.) Make :- Havells/KEI/Anchor
Supply, fixing, connecting & testing of sheet metal enclosures single pole and neutral with a two pin earth plug and socket complete with one single pole 20 amp MCB complete all as specified and directed.Make :- Legrand/Havells/C&S or equivlant
Supply, fixing, connecting & testing of sheet metal enclosures (IP-54 Protection) triple pole and earth with three pin earth plug and socket complete with one TPN 63 Amp MCB complete all as specified and directed..Make :- Legrand/Havells/C&S or equivlant
Supply, fixing, connecting & testing of sheet metal enclosures (IP-54 Protection) triple pole and earth with Five pin tempra Plug and socket (3P+N+E) 125 Amp complete with one TPN 125 Amp MCB complete all as specified and directed. .Make :- Legrand/Havells/C&S or equivlant
Supply, fixing, connecting & testing of sheet metal enclosures (IP-54 protection) triple pole and earth with Five pin tempra Plug and socket (3P+N+E) complete with one TPN 40/63 Amp MCB complete all as specified and directed. Make :-.Make :- Legrand/Havells/C&S or equivlant
Supply, fixing, connecting & testing of sheet metal enclosures double door (IP-42 Protection), triple pole and neutral, 4 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating complete all as specified and directed..Make :- Legrand/Havells/C&S or equivlant
All as per item 67 here-in-before but distribution board single pole and neutral, 12 way .Make :- Legrand/Havells/C&S or equivlant
All as per item 67 here-in-before but distribution board single pole and neutral, 8 way .Make :- Legrand/Havells/C&S or equivlant
All as per item 67 here-in-before but distribution board single pole and neutral, 4 way .Make :- Legrand/Havells/C&S or equivlant
Supply and fixing factory made epoxy powder coated distribution board VTP & N 4 ways (TPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TP-MCCB 160Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBs ) outgoings complete all as specified and directed. Make :- Legrand/Havells/C&S or equivlant
All as per item 71 here-in-before but distribution board VTP & N 8 ways (TPN MCB DB) for TP-MCCB upto 160 Amps. Make :- Legrand/Havells/C&S or equivlant
All as per item 71 here-in-before but distribution board TP & N 12 ways (TPN MCCB DB) for TP-MCCB upto 160 Amps. Make :- Legrand/Havells/C&S or equivlant
All as per item 71 here-in-before but distribution board TP & N 8 ways (TPN MCCB DB) for TP-MCCB upto 160 Amps. Make :- Legrand/Havells/C&S or equivlant
S&F MCCB, 3 pole, 250 Amps current rating and ultimate breaking capacity Icu = 25 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed. .Make :- Legrand/Havells/C&S or equivlant
All as per item 75 here-in-before but MCCB, 3 pole, 160 Amps current rating and ultimate breaking capacity Icu = 16 KA. Make :- Legrand/Havells/C&S or equivlant
All as per item 75 here-in-before but MCCB, 3 pole, 63 Amps current rating and ultimate breaking capacity Icu = 16 KA. Make :- Legrand/Havells/C&S or equivlant
All as per item 75 here-in-before but MCCB FP, 100 Amps having current rating 16 KA. Make :- Legrand/Havells/C&S or equivlant
All as per item 75 here-in-before but MCB TPN, 63 Amps (`C’ series) having current rating 10 KA. Make :- Legrand/Havells/C&S or equivlant
All as per item 75 here-in-before but MCB TP, 40 Amps (`C’ series) having current rating 10 KA. Make :- Legrand/Havells/C&S or equivlant
S&F MCCB, 4 pole, 125 Amps,415 volt current rating and ultimate breaking capacity Icu = 25 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed. Make :- Legrand/Havells/C&S or equivlant
All as per item 81 here-in-before but MCB SPN, 40 Amps (`C’ series) having current rating 10 KA. Make :- Legrand/Havells/C&S or equivlant
All as per item 81 here-in-before but MCB SPN, 32 Amps (`C’ series) having current rating 10 KA. Make :- Legrand/Havells/C&S or equivlant
All as per item 81 here-in-before but MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA. Make :- Legrand/Havells/C&S or equivlant
Supply and fixing in repair 8 Watt Recess mounted fixed LED down light made of extruded aluminium housing and high power LED as light source with diffuser and driver complete all as specified and directed by Engr-in-charge. Make :- Havells CAT Part No SPARLEPROFIXDLR8W830MOD or equivalent to Philips/Oshram.
Supplying, fixing in repair & testing decorative recess mounting 36 watt LED full out put luminaries suitable for Armstrong ceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories,connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable , including all accessories and fixing arrangements for fixing the light fitting to false ceiling complete all as specified and directed. Make :Bajaj cat part No BZRSQL 36W GZ1 NW "SKYLUX' Racess mounted 2x2 LED or equvlent Philips/CG
Supply& Fixing in repairs LED Batten fittings 20/22 Watt complete with round block etc, incl PVC gutties and flexible wire and connecting to ceiling rose complete . Model Wipro Garnet 20W , D532065 of Wipro or Eq model of Philips/Osram
S&F in repair Ultra bright glass 20W LED tube light with driver and high efficiency suited for installation in exsiting T8 fitting with G13 lamp holders complete all as specified and directed. Make :-Havells Cat part No -CRYSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Philips/Oshram
Supply and fixing 18 Watt ultra bright PL-L LED suitable for four pin lamp holder alongwith in built surge protection of 3KV complete all as specified and directed. Make WIPRO/Havells/Philips
S&F in replacement 8 Watt LED bollard light with uniformly lit diffuser and IP-65 protection including necessary concreate work complete all as specified and directed Make :- Cat Part No CONEBL8WLED857PSYMTOPC of Havells or equivalent in Oshram/Philips
S&F in repairs 18 W LED Driver suitable for PL-LED four pin lamp complete all as specified and directed by Engr-in-charge. Make: CG/Havells/Philips
Taking down carefully earth strip alumium of any size and any type from any height (3m to 16 m) of building or hangar ( roof conductor and down conductor) of Lightning protection and refixing the same with necessary insulators complete all as specified and as directed.
All as per above item but Air Termination rod of any size
Taking down carefully any light fitting from ceiling/wall and refixing the same along with necessary wires and fittings complete all as specified and as directed
All as per above item bu Celing fan of any make and capacity
Dismantling and taking down the serviceable Air Conditioner of 1.5/2/3 TR indoor and out door unit with voltage stabilizer and refixing the same at directed location complete all as specied and as directed. Note: 1. Proper pumping down of refrigirant is the responsiblity of the contractor. Any topping up of refrigirant gas required is included in the quoted rate, 2. Necessary insulation required for copper pipe is included in the quoted rate.
SHRI RAM CONSTRUCTION
M/s Raaj Construction Co.
M/s JAY AMBEY CONSTRACTION .CO
RADHA MADHAV CONSTRUCTIONS
m/s vikash Engineers
JNK BOND
M/s. Ravi and brothers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .