Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC | ₹1.9 Cr | L1 | Accepted-AOC accepted |
| 2 | L2₹2.1 Cr+₹10.6 L (5.43%)Rejected-Finance | ₹2.1 Cr+₹10.6 L (5.43%) | L2 | Rejected-Finance rejected |
| 3 | L3₹2.1 Cr+₹19.1 L (9.80%)Rejected-Finance | ₹2.1 Cr+₹19.1 L (9.80%) | L3 | Rejected-Finance rejected |
| 4 | L4₹2.2 Cr+₹26.2 L (13.5%)Rejected-Finance | ₹2.2 Cr+₹26.2 L (13.5%) | L4 | Rejected-Finance rejected |
| 5 | L5₹2.2 Cr+₹28.1 L (14.4%)Rejected-Finance | ₹2.2 Cr+₹28.1 L (14.4%) | L5 | Rejected-Finance rejected |
Tender Value
₹2.4 Cr
EMD Value
₹4.7 L
Closing Date
13 Aug 2020, 3:00 pmClosed
CCE(RND) SOUTH
PB NO. 1569 AKBAR ROAD SECUNDERABAD
Provision of civil works for Mini Block House at DRDL, Hyderabad
2020_DRDO_573564_1
83581/CIV/BH/CON
Limited
Civil Works
Item Rate
365 days
Hyderabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
CCE(RND) SECUNDERABAD
₹4.7 L
Yes
16 Sept 2020
25 Jul 2020
17 Aug 2020
25 Jul 2020
13 Aug 2020
31 Jul 2020
28 Jul 2020 - 30 Jul 2020
Amount
SUBHEAD - I : EARTH WORK :
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (a) All kinds of soil.
b)Ordinary rock
c)Hard rock (Blasting prohibited)
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (a) All kinds of soil.
b)Ordinary rock
c) Hard rock (Blasting prohibited)
Extra for every Additional Lift of 1.5 m or part there of in excavation / banking excavated or stacked materials.
a) All kinds of soil
b)Ordinary rock
Filling Available Excavated Earth (Excluding Rock) in trenches,Plinth sides of foundatios etc,in layers not exceeding 20cm in depth consolidating each diposited layer by ramming and watering,lead upto 50meter and lead upto 1.5meter
Supplying and filling of approved earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Supplying and filling in plinth with river sand under floors, including watering,ramming, consolidating and dressing complete.
Credit of Hard rock
SUB HEAD - II : ANTI TERMITE TREATMENT WORK:
Supplying chemical emulsion in sealed containers including delivery as specified. (a) Chlorpyriphos/ Lindane emulsifiable concentrate of 20%.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (a) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: (i) With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (a) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: (i) With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
SUB HEAD - III : PLAIN AND REINFORCED CEMENT CONCRETE WORK:
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
a) 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : a) 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying in position Machine Batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
a) All works upto plinth level.
b) All works above plinth level upto floor V level.
c) Extra for Deduction of not pumping of concrete to site of laying.
Providing and laying in position Ready Mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/recoverable separately)
a) All works upto plinth level.
b) All works above plinth level upto floor V level.
c) Add / Deduct for using extra cement in the items of design mix over and above the specified cement content therein.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
a)Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) including Providing & applying a coat of DAMP PROOF membrane approved on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification ( per 50 kg cement).
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundations, footings, bases of columns etc. for mass concrete.
b) Suspended floors, roofs, landings, balconies and access platform.
c) Lintels, beams, plinth beams, girders, bressumers and cantilevers
d) Columns, Pillars, Piers, Abutments, Posts and Struts.
e) Stairs, (excluding landings) except spiral-staircases
f) Weather shade, Chajjas, corbels etc., including edges.
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured). (a) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).
SUB HEAD - IV : BRICK WORK:
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : (a) Cement mortar 1:6 (1 cement : 6 coarse sand.
Providing and laying autoclaved aerated cement blocks masonry with 230 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Demolishing stone rubble masonry manually by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge
Credit for RR Stones
SUB HEAD - V : FINISHING :
Providing of 6mm cement plaster of mix in all surface with (a) cement mortar 1:3 (1 cement : 3 fine sand) at all levels.
Providing of 12 mm cement plaster of mix in all surface with (a) cement mortar 1:6 (1 cement : 6 fine sand) at all levels.
Providing of 15 mm cement plaster on the rough side of single or half brick / C.C wall of mix: (a) 1:6 (1 cement : 6 fine sand) at all levels.
Providing of 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Providing and Applying two coats of oil bound distemper of approved brand and shade over and including one coat of primer, including preparation of surface etc.,complete as directed.& with plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : (a) Two or more coats on new work.
Varnishing with varnish of approved brand and manufacture : (a) Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish. Including with French spirit polishing : (b) Two or more coats on new works including a coat of wood filler.
Providing & fixing chicken wire mesh at the junctions of RCC and C.C , 200mm overlapping on both sides with all necessary hardware etc., complete with guage and mesh size - 20swg and 20mm mesh
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
SUB HEAD - VI : FLOORING WORK:
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Polished Granite stone slabs 18 mm thick in steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying double charged vitrified floor tiles of Size 600x600 mm.(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Made of NITCO Company :Model name -Bermuda or Made of Somany ompany :Model name Celestial /Elegance series or Made of Kajaria company :Model name Super Glossy Nanotech K-6016/6018/6019/6101/6012 & Jhonson Make : Quarzet DK & Quarzet HL Or Equivalent
Providing and laying double charged Vitrified tiles of Size 600x600 mm. (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including routing the joint with white cement & matching pigments etc.Made of NITCO Company :Model name -Bermuda or Made of Somany ompany :Model name Celestial /Elegance series or Made of Kajaria company :Model name Super Glossy Nanotech K-6016/6018/6019/6101/6012 , Jhonson Make : Quarzet DK & Quarzet HL Or Equivalent.
Providing and laying rectified Glazed Non skid Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Make of NITCO Company : Model name Exotica/Maxima series or ,Made of Somany Company : Model name Trecker/Sprinkler series or , Made of Kajaria Company : Model Name GaniliaCrema /Beige/Almono Made of Johnson /Equivalent
Providing and fixing Ist quality Ceramic glazed wall tiles of Size 300x600 conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades as approved by Engineer-in-Charge, in skirting, and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Makes : Johanson , sandex Series or equivalent
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
SUB HEAD - VII : WOOD WORK / UPVC WORK :
Providing and fixing of IInd class teak wooden frames of size 100 x 150mm conforming,manufactured from commercial , including jamb, lock jamb, bead with M.S hold fast & finished with varnished of the surface as directed by Engineer-in-charge:
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 38 mm thick including ISI marked Stainless Steel butt hinges with necessary screws including Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters.
Extra for Not Providing and fixing ISI marked, IS : 1341, M.S. heavy weight butt hinges with necessary screws etc. complete : (a) 125x90x4.00 mm.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat.Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge.
Providing and fixing factory made UPVC white colour sliding or openable glazed window upto 1.65 m in height dimension comprising of uPVC multi-chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mmthick galvanized mild steel section made from roll forming process of requiredlength (shape & size according to uPVC profile), appropriate dimension of uPVCextruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile,zinc alloy (white powder coated) touch locks with hook, zinc alloy body with singlenylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm sizefor fixing frame to finished wall and necessary stainless steel screws etc. Profileof frame & sash shall be mitred cut and fusion welded at all corners, includingdrilling of holes for fixing hardware's and drainage of water etc.
After fixing framethe gap between frame and adjacent finished wall shall be filled with weather proofsilicon sealent over backer rod of required size and of approved quality, all completeas per approved drawing & direction of Engineer-in-Charge. (Single / double glasspanes, wire mesh and silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance indimension i.e. in depth & width of profile shall be acceptable. Variation inprofile dimension in higher side shall be accepted but no extra payment onthis account shall be made
a)Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.
Providing and fixing glazing in upvc door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the Architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): with float glass panes of 4.00 mm thickness (weight not less than 10 kg/sqm)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (a) Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete : a) 300x16 mm.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : a) 150x10 mm.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : a) 125 mm.
Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. a) Twin rubber stopper.
Providing and fixing of rubber nylon door buffer (dia of 40mm and 50mm long) on wall with rowl plug and screw.
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. comp
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, with necessary accessories and screws etc. complete.
Providing and fixing stainless steel ( Grade 317) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
SUB HEAD - VIII : WATER PROOFING & FALSE CEILING WORK
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm).
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (i) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (ii) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
(iii) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (iv) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (v) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm
Providing and fixing on wall face unplasticised Rigid Single socketed PVC rain water pipes conforming to IS : 13592 Type A, along with injection moulded fittings as required e.g., bends on any angle, sockets, junction, cowls, offsets, access pieces, including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, providing and fixing MS stays & clamps and cutting & making good the holes in floors and walls wherever required etc. all complete. (For Rain water pipe).
(a) 110 mm diameter.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I.
wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint , all as per manufacturer's specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (a)12.5 mm thick tapered edge gypsum moisture resistant board. (Make : Gproc , L Strong , Armstrong)
12.53 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
Providing and fixing of wall panelling using commercial plywood 11mm thick MDF Board finished with 3.5mm thick decorative veneer of approved shade conforming to IS : 1328 (type-1), inside 22m thick medium density fibre frame & rockwool insulation including decorative pattern and finish with mallamine polish including preparation of drawings etc., complete as directed by engineer-in-charge.
SUB HEAD - IX : SANITARY INSTALLATIONS WORK :
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :Size : 71 x36 x 81 cm (Cat no:- 20101 (s-22)) (a) W.C. pan with ISI marked white solid plastic seat and lid. (Make : Hindware,Jaquar or equivalent)
Providing and fixing white vitreous china flat back smalll urinal of size 26.5 X 31.5 X 44 CM with white PVC automatic flushing cistern,with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the walls and floors wherever required : (a) Single half stall urinal P.V.C. manual flushing cistern (Make : Hindware,Jaquar or equivalent).
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (a) White Vitreous China Table Top Basin (Make : Hindware,Jaquar or equivalent) (Hindware Cat. No. -10001)
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in- charge.(Make : Hindware,Jaquar or equivalent) (Hindware Cat. No. -F850015)
Providing and fixing Stainless steel connection for flush pipe of Grade 304 stainless steel connecting with wash basin, W.C. pan.(Make-Alton ALT2005,Havells or equivalent)
Providing and fixing 600 x 300 mm beveled edge Mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete as per the direction of Engineer-in- charge.(Make : Saint Gobain ,Cera or equivalent) model-5567
Providing and fixing toilet paper holder : (a) C.P. brass.(Make : Hindware,Jaquar or equivalent) (Hindware Cat. No. -F880003)
Providing and fixing liquid soap container of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (Make : Jaquar or equivalent)
Providing and fixing CP liquid soap dish (brass) 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 205gms. (Make : Jaquar or equivalent)(Hindware Cat. No. F880011)
Providing and fixing CP towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (a) 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.(Make : Hindware,Jaquar or equivalent) (Hindware Cat. No. F880005)
Providing and fixing C.P. brass bib cock with wall flange of approved quality conforming to IS:8931 : (a) 15 mm nominal bore (Make : Jaquar or equivalent)
Providing and fixing C.P. brass Angular stop cock (concealed) of standard design and of approved make conforming to IS:8931 as per the direction of Engineer-in- charge.(Model No, - CON-CHR-059KN) (a)15 mm nominal bore.(Make : Jaquar or equivalent)
Providing and Fixing Health Faucet HINDWARE Cat.No-F160068 or JAQUAR Cat. No. 573 (ALLIED SERIES) or equivalent make KINGSTON-AGR ACS 49/KOHLER Cat. No. 12925IN-CP (HEALTH FAUCET W/WHITE SDSPRAY, M HOSE) with flexible pipe and wall hook with each European W.C. Pan.
Providing and fixing Nahani Trap of size 110 X 75mm. (Make : Birla Aerocon or equivalent)
SUBHEAD - X : SOIL WASTE AND VENT PIPE AND FITTINGS WORK:
Providing and fixing SWR uPVC pipes (Type-B) confirming to IS 13592 : 1992 complete with all fittings e.g. plain or door bends, junctions, cowls, offsets, access pieces etc. jointing with rubber rings and solvent cement including fixing the pipes on wall face with MS galvanized holder bat clamps or suspended below ceiling with MS galvanized hangers/supports and fasteners all as approved by the engineer in charge including Cutting holes in walls, floors excavation, refilling and disposal of surplus earth wherever required and making good . (a) 110 mm dia.
Providing and fixing uPVC deep seal 'P' or 'S' of self cleansing design with or without vent arm with provision for connecting uPVC inlet fitting complete including cost of cutting and making good the walls and floors wherever required. (a) For 110mm inlet and 80mm outlet.
Providing and fixing uPVC threaded waste pipes (I.S:4985-2000) Class - 6 including all fittings e.g bends, junctions, elbows, tees, offsets etc. jointing with screwed joints including cutting holes in walls, floors excavation, refilling and disposal of surplus earth wherever required and making good.
(a) 32 mm nominal bore.
(b) 50 mm nominal bore.
(c) 80 mm nominal bore.
SUBHEAD - XI : WATER SUPPLY SYSTEM:
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work
Supplying and fixing in position best quality and approved make heavy quality screws down gun metal gate valves with hand wheel of the following sizes fixed to service lines including testing, making good the leakages, if any etc.,
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External Work
(a) 32 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
(a) 32 mm nominal bore.
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : (a) With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.
Providing & Fixing HDPE O.H water storage tanks of the approved quality, & of the following capacity including making solid supported base as per instructions & doing all connections as required to make the work complete in all respects.
A)1000 litre Circular tank.
Providing & fixing sqare mouth S W Gully trap grade A complete with CI grating brick machinery chamber with water tight C I cover with frame of 300x300 mm (Size inside ) The weight of cover to be not less than 4.5 kg & frame to be not less than 2.70 kg as per standard design.
a)100x100 mm size P type.
SUBHEAD - XII : EXTERNAL SEWERAGE SYSTEM
Excavating trenches of required width for pipes etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
a)80 mm dia. but not exceeding 300 mm dia
Providing and laying of 150 dia s.w pipe including honching around the pipe in 100mm thick with cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:
a)150 mm diametre S.W. pipe
b)100 mm diametre S.W. pipe
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : (a) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
SUB HEAD - XIII : ROAD & DRAINS
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.
a)All kinds of soil
Supply of approved moorum obtained from outside MOD land filling in layers not exceeding 20cms thick at all heights and depths in foundations, pits, trenches, sewer lines around structures and foundation under floors other places including dressing and levelling watering, consolidation to achieve minimium of 95% proctor density etc., complete as per drawing specifications, payments shall be made for the quantity after deducting the voids.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Preparation of Subgrade
Providing and laying cement concrete :1:2:4 (1 cement : 2 coarse sand 4 graded stone aggregate 20mm nominal size) in pavements, laid to required slope and camber in panels as required including mixing of hardening compound of approved quality as per manufacturers specification in cement concrete, consolidation finishing and tamping complete using steel form work with sturdy MS channel sections, curing, making provision for contraction/expansion, construction & longitudinal joints (10mm wide x 50mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
(a) All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
a)1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Random Rubble Masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
a)Cement mortar 1:6 (1 cement : 6 coarse sand).
Providing of 12 mm cement plaster of mix in all surface with (a) cement mortar 1:6 (1 cement : 6 fine sand) at all levels.
SUB HEAD - XIV : ARBORICULTURE:
Supply of Grass and planting by dibbling the area including watering & Maintenance of Lawn for 30 days or more till grass forms a thick lawn cushion free from weeds. With Doob Grass (15 cm x 15 cm apart) including one year maintenance after completion of work
Trees:- Digging of pits of size 1x1x1m and refilling with good agriculture soil and well decomposed cattle manure in 4:1 ratio. Supply and planting of approved Tree species of healthy grownup saplings with good root system. Saplings should be of minimum 4 ft height from ground level after plantation. Maintenance includes, regular watering, de-weeding, loosening of soil fortnight, manuring with cattle manure and fertilizer, training, pruning, staking and spraying of insecticide and fungicide, including one year maintenance after completion of work
Shrubs: Digging of pits of size 0.60x0.60x0.60m and refilling with good agriculture soil and well decomposed cattle manure in 3:1 ratio. Supply and planting of approved Shurbs species of healthy grownup saplings with good root system. Saplings should be of minimum 2 ft height from ground level after plantation. Maintenance includes, regular watering, de-weeding, loosening of soil fortnight, manuring with cattle manure and fertilizer, training, pruning, staking and spraying of insecticide and fungicide,including one year maintenance after completion of work
Hedges: Digging of trenches of size 0.30 x 0.30m (width & depth) and refilling with good agriculture soil and cattle manure in 4:1 ratio. Maintenance includes, regular watering, de-weeding, loosening of soil fortnight, manuring with cattle manure and fertilizer, pruning, shaping and spraying of insecticide and fungicide,including one year maintenance after completion of work
Flower Beds: Digging upto 0.10m refilling with good soil and cattle manure in 3:1 ratio. Preparation of beds supply and planting of healthy grown up plant material. Maintenance includes regular watering, de-weeding, manuring with manure and fertilizer.pruning, shaping and spraying of insecticide and fungicide,including one year maintenance after completion of work
Potted Plants: Supply and maintaining the Indoor and Outdoor potted plants in a good healthy and disease free condition of various varieties and in 300 mm Dia.PVC Plastic Pot.
Pipe Line:- Supply, fixing, testing and commissioning of HDPE pipes with spray nozzles ISI mark with all required accessories, outlet points etc., (excluding excavation in hard rock if any will be measured separetly) in all kind of soil, back filling and ramming as required and disposal of surplus earth within the site, as directed by Engineer - in - charge.
32mm dia
SUB HEAD - XV : FURNITURE WORK:
Supply & placement Unlearn 1 Seater CPU / Laptop size shall be 900 Width mm x 600 Depth mm x 680 Height mm. Top shall be 25 mm thick , Base material shall be 25 mm thick
Supply & placement of sofa PISA 1 str of Godrej make or equivalent
Supply & placement of plastic chairs of size W x H x D: 600 mm x 830 mm x 550 mm Make Neelkamal /Equivalent
Supply & placement of Discussion Table for 8 persons made out of 18mm Plywood with 3.5mm th vineer top to have PU Finish with Melamine Polish of approved shade of Senate Make Godrej /Wipro/Featherlite
Supply & placement of High back with revolving type with P.U. arms with fittings gas left system with seat & back cushion of approved shade complete.marvel chairs Make Godrej /Wipro/Featherlite
Supply & placement of Discussion Chairs with revolving type with P.U. arms with fittings gas left system with seat & back cushion of approved shade complete.Bravo Mid Back chairs Make Godrej /Wipro/Featherlite
Supply & placement of working staff table of size 1500mm x 750mm x 750mm made out of 19mm thick finished with two or more coat of spirit polish afate wood filler,all necessary hardware and fittings shall be of SS 316 grade and as per direction of Engineer in Charge. Make Godrej /Wipro/Featherlite
Supply & placement of staff Chair of size 450x450x450mm with revolving type, synchro fit mechanism and cushions for seat and high back with upholstery of approved shade and casters etc., as per direction of Engineer in Charge. Make Godrej /Wipro/Featherlite
Supply & placement of Officer Table of size 2100 x 1050x750 mm made out of 18mm plywood with 1 mm thick laminated of approved shade with four drawers and with front of 12mm thick with all exposed edges to have teakwood beading with melamine poilish finish and all internal surfaces with 0.8 mm laminate of Godrej make equivalent
Providing and fixing tile carpet of M/s Muraco or approved equivalent make multi level loop, unicoloured yarn, 100% solution dyed etc complete
Providing & fixing levelor 10mm vertical blinds having top rall 39mm x 34mm high with wall thickness of 1.2mm having 25mm decorative insert. Control unit shall be of Derlin Plastic runner shall be moulded from Derlin Plastic with antifriction head rail and the top end of the louvers shall not exceed 0.5cm. The louver fabric shall be polyster viscose/polyster yarn dyed in fast colour with or without protective coating on lourvers with chemical for stain resistance & soil repetancy and shall have GI weight and steel / polymer ball chain for spacing. The top rall should be fixed on bracket of 14 SWG galvanized spring steel fixed firmly on walls by nylon plug and screw as per approve design and direction of the Engineer in Charge.
Supply and installation horizontal roller blinds made out of imported fabric including of all hardware fitting like cord, rope, brackets etc all complete of Vista make or equivalent.
SUB HEAD - XVI : WATER COOLER :
Aquaguard Purechill RO storage Cooler cum Purifier with its one of a kind purification technology (RO),with cooling and storage solution of following specification.Approximate External Diamension (WXDXH) 640X450X1350mm Operating Power Supply 230 ±10% V AC,50Hz b)Filter Catridges-Sediment,Activated Carbon,Carbon Block Running Current in Amps.(Max) 4.5 ± 10% Power in Watts(Max) 700 ± 10 % Water Storage Tank Capacity 80Ltr. Capacity with Comfort Level Water Outlet Temperature at 17°C ± 1° C 60 Ltr Compressor Make Copeland or Tecumseh Refrigerant Freon 22 Stages Details.
1.Particulate Filter
2.Pre Carbon Block Filter
3.Anti Scalant Filter
4.Sediment Filter
5.Reverse Osmosis membrane Filter
6.Post Carbon Block Filter
7.Nano Silver Leaching Filter
RO Membrane Rating 4No.x75 GDP or Equivalent Make.Kent/Eureka forces or equivalent
SUB HEAD -XVII : AIR CONDITIONING:
SUB-HEADING-1: VRF SYSTEM
VRF SYSTEM (OUTDOOR UNIT):
Supply, Installation, Testing and Commissioning of following capacities of Vairable Refrigerant Flow (VRF / VRV) Outdoor condensing unit comprising of Invertor SCROLL compressor's, Heat Exchanger, propeller / axial fans, refrigerant Circuit, Safety Devices & Oil Recovery System, operating on R410a refrigerant gas. Necessary Refrigerant Gas and oil charge. Compressor shall be equipped with inverter controller of Insulated Gate Bipolar Transistor (IGBT) type to be efficient & quiet. The outdoor unit shall have the multi-step of capacity control to meet load fluctuation and indoor unit individual control. Heat Exchanger shall be constructed with copper tubes mechanically bonded to aluminium fins to form a cross fin coil. Refrigerant Circuit shall include an accumulator, liquid and gas shutoff valves and a solenoid valves. The Outdoor unit shall include the following safety devices : High pressure switch, Low pressure switch, Fan motor safety thermostat, Inverter overload protector, Over Current relay, Fusible plugs, Fuses etc . Unit shall be equipped with an oil recovery system to ensure stable operation with long refrigerant piping. The unit shall be prewired in factory for necessary power and control wiring. All outdoors units shall be mounted with necessary vibration isolators ,Complete clamping and saddling of cabling work and refrigerant piping; as per the specifications and approved drawings
Nominal Cooling Capacity at ARI conditions
12 HP OUT DOOR UNIT
CEILING SUSPENDED UNIT (CSU)
Supply, Installation,Testing and Commissioning of High Static Ducted type Indoor unit with pre-filter (EU - 4),fan section with low noise level, multispeed fan motor, coil section with DX coil, outer cabient, condensate drain pump, insulation, pipe connections, including necessary control wiring, required Fire retardant canvass connections with GI . powdercoated finish angle flanges on both sides,etc. as necessary. Unit to be provided with microprocessor with Corded remote controller as per the specifications and approved drawings.
4WAY CASSETTE UNIT
Supply, Installation,Testing and Commissioning of FOUR WAY CASSETTE Type indoor unit. The housing of the unit shall be powder coated galvanised steel andshall include prefilter, fan section, coil section , fan section with low noise fan with Multi speed motor ,condensate drain pump , Insulation, pipe connections , including necessary control wiring, all necessary controls, valves and fittings, strainer, drier , Fresh air intake and operating on R410a refrigerant gas. The fan shall be with Aerodynamically designed diffuser turbo fan type. The cooling coil shall be of seamless copper tubes and shall have aluminium fins. Unit shall have filter cleanable type of resin net fixed to an integrally molded plastic frame. Unit shall have four way supply air grilles on sides and return air grill in center. Unit shall have high lift drain pump, fresh air intake provision, low gas level detection system. Unit shall have an electronic expansion valve which control refrigerant flow rate in respond to load variations of room. Unit to be provided with microprocessor with Corded remote controller LCD type as per the specifications and approved drawings.
REF. PIPE JOINTS
Supply, Installation, Testing and Commissioning of Refrigerant Piping Joint For Suction Line.
Supply, Installation, Testing and Commissioning of Refrigerant Piping Joint For Liquid Line.
REFRIGERANT PIPING:
Supply, Installation, Testing and Commissioning of Hard copper REFRIGERANT PIPING of 16swg various sizes with necessary supports, fittings, interconnecting the liquid and suction lines between the aircooled outdoor units and the indoor units. The piping shall be carried out of Hard drawn copper pipes of type 'K with soldered / brazed socket fittings. Isolating valves shall be provided to isolate each compressor, strainers, sight glass and any other component requiring proper operation and maintenance. Both the suction and liquid lines shall be insulated with 19mm thick closed cell insulation for above 25mm dia , 13mm thick for pipes below 25mm dia . The insulation finished with treated woven glass fiber reinforced covering and further with 2 layers of protective coating of weather proof starbond 30-36 for all ref. Piping and covered with 24G AL cladding for exposed Piping and including making required holes in the wall and re finishing and water tight of holes after laying holes as per the specifications and approved drawings.
Supply, Installation, Testing and Commissioning of Hard copper REFRIGERANT PIPING of 16swg various sizes with necessary supports, fittings, interconnecting the liquid and suction lines between the aircooled outdoor units and the indoor units. The piping shall be carried out of Hard drawn copper pipes of type 'K with soldered / brazed socket fittings. Isolating valves shall be provided to isolate each compressor, strainers, sight glass and any other component requiring proper operation and maintenance. Both the suction and liquid lines shall be insulated with 19mm thick closed cell insulation for above 25mm dia , 13mm thick for pipes below 25mm dia . The insulation finished with treated woven glass fiber reinforced covering and further with 2 layers of protective coating of weather proof starbond 30-36 for inside Piping and including making required holes in the wall and re finishing and water tight of holes after laying holes as per the specifications and approved drawings.
DRAIN PIPE:
Supply, Installation, Testing and Commissioning of CPVC (Chlorinated Poly Vinyl Chloride) pipes condensate drain piping insulated using 9 mm thick nitrile rubber tubes including fitting and supports as per the specifications and approved drawings.
AIR DISTRIBUTION SYSTEM
Supply, Installation, Testing and Commissioning of factory fabricated GSS Ducting as per SMACNA/DW standards with splitters,bends, elbows, vanes, supports,neoprene of minimum 6mm thick gasket, nuts, bolts angle iron flanges, soildered longitudinal joints ,GI full threaded rods hung to minimum 12 mm dia HILTI make anchor fastner as required and epoxy painted slotted rail supports ,as per the specifications and approved drawings.
INSULATION
Supply, Installation, Testing and Commissioning Thermal Insulation of Supply air ducting with 19mm thick closed cell elastrometric Nitrile rubber with factory laminated aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives and finished with 0.05mm thick 3" wide aluminium foil faced self adesive tape at all joints, & The insulation finished with treated woven glass fiber reinforced covering and further with 2 layers of protective coating of weather proof starbond 30-36 for all duct insulation as per the specifications and approved drawings.
Supply & Installation of Duct Accoustic Insulation with microban applied inside of the duct work with 10MM thick Nitrile Rubber fixed using sticker pins and adhesive. Material density minimum of 140 kg/m3 & conform to Class 1 surface spread of flame as per BS 476 Part7 and in accordance with UL 94, 1996 and tested as per ISO354 for sound absorption coefficient.
DAMPERS,GRILLES & DIFFUSERS
Supply, Installation, Testing and Commissioning of Opposed type GI Volume Control dampers with matching flanges of sizes as per the approved drawings
Supply, Installation, Testing and Commissioning of Opposed type GI Backdraft dampers with matching flanges of sizes as per the approved drawings
Supply, Installation, Testing and Commissioning of Extruded Al. Powder coated ceiling square diffusers for Supply & Return as per the specifications and approved drawings.(Colour to be aproved by dept)
Supply, Installation, Testing and Commissioning of Extruded Al. Powder coated Collar Dampers as per the specifications and approved drawings.(Colour to be aproved by dept)
Supply, Installation, Testing and Commissioning of weather proof extruded aluminium powder coated fresh air louver of non vision type of Perforated Al net, VCD etc as per the specifications and approved drawings.
ELECTRICAL
Supply, Installation, Testing & Commissioning of 40Amps MCB/ELCB/MCCB enclosed in a IP65 protection box suitable for outdoor application near VRF Outdoor Unit.
Supply, Installation, Testing and Commissioning of POWER CABLING of Copper cable for indoor / outdoor units to be suitably laid in PVC conduit as per site requirement.
4C x 10 sq.mm. (Copper)
3C x 2.5 sq.mm. (Copper)
Supply, Installation, Testing and Commissioning of CONTROL CABLING of 3C x 1.5 sq.mm. copper cable for communication between indoor and outdoor units to be suitably laid in PVC conduit as per site requirement.
Supply, Installation, Testing and Commissioning of REMOTE CABLING of 4C x 1.0 sq.mm. copper cable for communication between indoor and outdoor units to be suitably laid in PVC conduit as per site requirement.
EARTHING SYSTEM:
Supply, Installation, Testing and Commissioning of GI flat 25 mm x 3 mm.
Supply, Installation, Testing and Commissioning of Single core Green PVC insulated 2.5 sq mm. wire.
Supply, Installation, Testing and Commissioning of powder coated GI Cable tray of perforated type 300mm wide with GI cover (both 2mm thick) including suitable powder coated MS supports as per the specifications and approved drawings.
Supply, Installation, Testing and Commissioning of powder coated GI Cable tray of perforated type 150mm wide with GI cover (both 2mm thick) including suitable powder coated MS supports as per the specifications and approved drawings.
SUB HEADING-2: DX-SYSTEM
HI-WALL SPLIT UNIT (INVERTER TYPE):
Supply of HI-WALL SPLIT UNIT with indoor and outdoor units with Inverter compressors including proper mounting arrangement and accessories. Indoor unit comprises of pre filter, Coil Section, evaporator section, low noise Multi speed fan, all refrigerant accessories & cordles remote controller with LCD Display, etc. as necessary and Mounting Stand for outdoor unit. Power from nearest socket to indoor/ outdoor unit as per the specifications and approved drawings. (R410A /R32 Refrigerant).
REFRIGERANT PIPING:
Supply, Installation, Testing and Commissioning of SOFT COPPER 18 swg REFRIGERANT PIPING 18 swg for high wall units of various sizes with necessary supports, fittings, interconnecting the liquid and suction lines between the aircooled outdoor unit and the indoor unit. Both suction and liquid line shall be insulated with 13 mm thick nitrile rubber tubes as insulation material and The insulation finished with treated woven glass fiber reinforced covering and further with 2 layers of protective coating of weather proof starbond 30-36 for inside & outside piping, and including making required holes in the wall and re finishing and water tight of holes after laying holes as per the specifications and approved drawings.
DRAIN PIPE:
Supply, Installation, Testing and Commissioning of CPVC (Chlorinated Poly Vinyl Chloride) pipes condensate drain piping insulated using 9 mm thick nitrile rubber tubes including fitting and supports as per the specifications and approved drawings.
ELECTRICAL
Supply, Installation, Testing and Commissioning of POWER CABLING of Copper cable for indoor / outdoor units to be suitably laid in PVC conduit as per site requirement.
3C x 2.5 sq.mm. (Copper) (form indoor/Outdoor to power socket)
Supply, Installation, Testing and Commissioning of CONTROL CABLING of 3C x 1.5 sq.mm. copper cable for communication between indoor and outdoor units to be suitably laid in PVC conduit as per site requirement.
EARTHING SYSTEM:
Supply, Installation, Testing and Commissioning of GI flat 25 mm x 3 mm.
Supply, Installation, Testing and Commissioning of Single core Green PVC insulated 2.5 sq mm. wire.
Supply, Installation, Testing and Commissioning of powder coated GI Cable tray of perforated type 150mm wide with GI cover (both 2mm thick) including suitable powder coated MS supports as per the specifications and approved drawings.
SUBHEAD-XVIII INTERNAL ELECTRIFICATION
Wiring for light point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy class FRLS PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc as required.
Group-A
Group-B
Group-C
Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of 1.5 Sq.mm FRLS insulated multistranded Copper wires, run in & including 25mm dia, 2mm thickness FRLS PVC ISI mark conduits concealed in wall after necessary chase cutting with finishing/surface in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI Switch box with modular switch and the box covered with front plate.
Two Lights point controlled by one 6A switch.
Three Lights point controlled by one 6A switch.
Four Lights point controlled by one 6A switch.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed heavy FRLS PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cableetc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Point Wiring for Light with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of 1.5 Sq.mm FRLS insulated multistranded Copper wires , run in & including 25mm dia, heavy guage FRLS PVC conduits concealed in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, weather proof (IP55) Switch box with modular switch and the box covered with front plate.
One Light point controlled by one 6A switch.
Supply and wiring similar to item 1 above but for Ceiling Fan point including GI box and controled by one 6A switch, 100W Step type Electronic regulator with Concealed MS fan hook box.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class FRLS PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Light/Fan Fixtures
Supply, Installation, Testing & Commissioning of the following Light Fixture with lamp, Control Gear & All necessary accessories. Luminaries with all electrical accessories & it should be energy efficient, etc are prewired up to the terminal block & mounted on a removable control gear module for ease of maintenance. All electrical connections of the control gear module with the rest of the luminaries should be click fix & require use of no tools. Mounting options should be for both lateral as well as pole top mounting with Lamp Control Gear & Fixing Accessories. All fixtures shall be white colour & supplied with white lamps. All the light fixtures will be finally approved by Architect / Consultant/ Department. Architect / Consultant / Department reserves the right to reject the fittings suggested by the contractor.
18W (4Feet) LED Light Fixture (Philips : BN021C LED20S PSU CDL GR)
15W LED surface mounted fixture (Philips : SM251C LED20S SLEEK SURFACE)
15W LED recess mounted fixture (Philips : DN153 GREENLED SMART 15W)
36W LED recess mounted fixture (Philips : RC380B LED30S-6500 L60W60 PSD OD S1)
36W LED surface mounted fixture (Philips : SM365C LED33-6500 PSU-OD WH)
LED Decorative Wall mounted light Fixture (Philips : WT140W LED7S CW PSU S1 PC)
Ceiling Fans
Supply and fixing of Ceiling fan of following sweep (white colour), suitable for operation on 230 / 240V, 50 Hz, single phase, A.C, supply complete with double ball bearing motor, required down rod, capacitor, three MS blades etc complete.
1200mm Sweep 5 Star rated Ceiling fans
Exhaust Fans
Supply, Installation & Testing of following 900 RPM exhaust fan suitable for single phase, 240V, AC supply complete with motor, MS louvers, mounting brackets, all accessories etc complete.
300mm Sweep
380mm Sweep
Supply Installation Testing and commissioning of TPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB /ELCB as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in concealed in wall after necessary chase cutting with finishing/surface in wall including all fixing materials required. MCBs shall conform to IS : 8828 and ELCB shall conform to IS :12640. All MCBs shall be 'C' Curve. DBs shall be provided along with required wire adopter boxes around the DB as required and dummys for spare ways in the DB (No claim shall be allowed for the same).
4Way TPNMCBDB with 40A, 100mA 4Pole RCBO as incomer and 9 nos 6-25A SPMCBs and 3nos 8KA SP SPDs as outgoings. (LDBs)
8Way SPNMCBDB with 32A 2Pole RCBO as incomer and 6 nos 16-25A SP MCBs as outgoings.
Supply and laying of following dia. NP2 grade RCC hume pipes with collars for road crossings, laid 750mm below ground level including excavation, back filling etc., complete.
300mm dia.
150mm dia
Providing Chain Link fencing around Transformer yard upto 2.4m height with a continuous brick masonry kerb wall of 600mm above ground with suiatble foundation and palstering of the same as per standard practice.
Supply and fixing of 1.5X2.4m MS weld mesh gates for Transformer yard as per standard design and with earth connection from fence
Spreading of two layers of 40mm stone metal inside the Transformer yard
Providing and fixing PCC Foundation for Electrical Equipment like HT panels, Transformers etc., in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including nominal reinforcement, necessary excavation, shuttering and centering etc., Complete for Electrical Equipment like HT panels, Transformers etc foundations.
Earthing
Providing maintenance free Earth station with consisting of 40mm dia pipe standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, seald at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5mtrs. Earth enhancement compound upto a depth of 2.0meters arround the electrode capsule. Brick chamber & CI Cover complete.
Providing maintenance free Earth station with consisting of
- 65mm dia, standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, seald at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5mtrs.
- Earth enhancement compound upto a depth of 2.0meters arround the electrode capsule.
- Brick chamber & CI Cover complete.
Supply and laying of following size earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories when laid in trench with necessary interconnections with earth station and equipments.
50 X 5mm GI strip
Supply & laying in ground
Supply & laying in existing trench / hume pipe
25 X 5mm GI strip
Supply & laying in ground
Supply & laying in existing trench / hume pipe
8 SWG GI wire
Supply and laying of following size earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories and terminations when laid in trench with necessary interconnections with earth station and equipments.
25 X 5mm Copper strip
Brass or bronze flat bar 6x32x250mm mounted on two DMC Insulators (such as acro type 4649) holes of 8mm dia to accomidate 1/4" connection blots with washers and butterfly nuts all made of brass or copper.
Supplying and fixing of following sizes of heavy class FRLS PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supply and laying of 25mm dia. 2mm thick PVC conduit concealed in wall/ ceiling/floor and drawing of 12SWG GI wire as fish wire for laying of LAN Cables at a later stage and supply of all fixing accessories such as junction boxes, conduit bends, etc., complete as required.
SUBHEAD-XIX POWER WIRING
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supply and fixing of factory made single phase 25A Metalclad socket with 25A SPMCB in MS box including all fixing accessories.
Supply and fixing of Three phase 32A 3P+N+E wall mounted switched interlocking sockets and surface mounting with 3P+N+E plug including all fixing accessories.
Supply and fixing of Three phase 63A 3P+N+E wall mounted switched interlocking sockets and surface mounting with 3P+N+E plug including all fixing accessories.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class FRLS PVC conduit as required
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supply Installation Testing and commissioning of TPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB /ELCB as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in concealed in wall after necessary chase cutting with finishing/surface in wall including all fixing materials required. MCBs shall conform to IS : 8828 and ELCB shall conform to IS :12640. All MCBs shall be 'C' Curve. DBs shall be provided along with required wire adopter boxes around the DB as required and dummies for spare ways in the DB (No claim shall be allowed for the same).
6Way TPNMCBDB with 63A, 100mA 4Pole RCBO as incomer and 15nos 6-25A SPMCBs and 3nos 8KA SP SPDs as outgoings.
Supply and fixing of following HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461, Steel wire mesh cable trays with internal dimensions & load bearing capacities as given below, including couplers, mounting accessories with including all fixing accessories and including 2runs of 25x5mm GI strip along with cable tray etc., complete as required.
150mm x 54mm, The Load bearing capacity of the Cable Trays should be minimum of 29.51KG/meter at the span of 1.5Meter.
300mm x 54mm, The Load bearing capacity of the Cable Trays should be minimum of 57.66KG/meter at the span of 1.5Meter
SUBHEAD XX : SHOP ELECTRICALS
MV Panels
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA/Galvanised steel enclosure for main frame and 1.6mm thick partitions and shall have IK Certification as per IEC 62262 for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below.The panel shall be got fabricated from manufacturers as per IEC 61439(Part-1&2). Indoor panels shall have IP-4X degree of protection and outdoor panels shall have IP-55 degree of protection wiith external door. Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose.
Building Panel
Incoming :
160A, 35KA TP+NL MCCB with O/C, S/C & ELR with CBCT - 1set
Busbars :160A TPN Aluminium busbars - 1 set
(Neutral shall be 100% Phase busbar)
Outgoings :
63A 25KA TP+NL MCCBs - 5nos
40A 25KA TP+NL MCCBs - 5nos
63A,35KA FP MCCB with TVSS - 1set
Metering :
LED Phase indication lamps with individuals Fuses and control with toggle switches- 1sets
CT Operated Load Manager with RS 485 port ( Similar to EM-6400) – 1sets
SUBSTATION ACCESSORIES
Supply and laying of 2.0mm thick 3.3KV Rubber Mats as per IS 15652 of size1000mm x2000mm
Supply and erecting 4.5KG Carbon Dioxide (CO2) Fire Extiguisher with necessary clamps made from 50 x 6mm M.S. Flat with Nut & Bolts growted in wall complete.
Providing printed instruction chart both in English, Hindi and local launguage and duly framed with front glasses, for treatment of person suffering from Electric shock.
Supply and Fixing of Laminated SLD-A1size
Providing pair of rubber hand gloves suitable for working on 11 KV
Supply and fixing of Danger Notice boards
Supply and fixing of outdoor type 4nos 9Ltrs Fire buckets round bottom type enamelpainted, white inside & Red out side with FIRE mark, filled with dry sand and Supply and erecting floor mounting stand for keeping four nos. of FIRE buckets comprising 1500mm in length, 900mm height frame made out of 30mm x 30mmx 4mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of approved enamelled silver paint.
SUBHEAD XXI : UPS WIRING
Supply and fixing of modular type single phase 2nos 6A 5pin shuttered type Socket with 1no 16A switch with front plate and anodised GI box including all fixing accessories.
Supply and fixing of modular type single phase 1no 16A 6pin shuttered type Socket with 1nos 16A switch with front plate and anodised GI box including all fixing accessories.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed heavy class FRLS conduit as required
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supply Installation Testing and commissioning of TPN MCB Double door Distribution boards dust, water proof and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB /RCBO as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in flush with wall including all fixing materials required. MCBs shall conform to IS : 8828 and ELCB /RCBO shall conform to IS : 12640. All MCBs shall be D Curve.
4Way TPNMCBDB with 40A 4Pole MCB & 4P 32KA SPDs as incomer and 12nos 6-25A SPMCBs as outgoings.
SUBHEAD XXII : TELEPHONE CONDUITING
Supplying and fixing of following sizes of heavy class FRLS PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supply and laying of 25mm dia. 2mm thick PVC conduit concealed in wall/ ceiling/floor and drawing of 12SWG GI wire as fish wire for laying of LAN Cables at a later stage and supply of all fixing accessories such as junction boxes, conduit bends, etc., complete as required.
Supply and fixing of Telephone outlet (RJ11) with anodised GI box of with front plate and telephone socket
Supply and fixing of LAN outlet (RJ45) with anodised GI box of with front plate
Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supply and installation of following size Krone connectors in MS box complete as required.
Supply and laying of following size 0.5mm dia Jelly filled copper conductor armoured Cables in ground at 600mm below ground level including excavation, and refilling of earth, laying of cables, providing protection with sand and bricks on top and sides and Telephone cable route markers at every 50mtrs interval complete with including all terminations as required and as directed by Engr-in-charge. The cable shall be as per the DOT specifications.
SUBHEAD XXIII : SPECIAL EARTHING
Providing maintenance free Earth station with consisting of
- 65mm dia, standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, seald at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5mtrs.
- Earth enhancement compound upto a depth of 2.0meters arround the electrode capsule.
- Brick chamber & CI Cover complete.
Supply and laying of following size earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories when laid on the wall with necessary interconnections with earth station and equipments.
25 X 5mm Copper strip with DMC Insulated Supports
25 X 5mm Copper Strip laid in Ground
50X5mm GI Strip
Welding using Bi Metallic strips between copper and GI / MS Rod
Supply and fixing of Static Discharge Handles made out of 20mm dia & 600mm length Copper rod fixed on wall with brass spacers and conected to 25x5mm copper strip.
Brass or bronze flat bar 6x32x250mm mounted on two DMC Insulators (such as acro type 4649) holes of 8mm dia to accomidate 1/4" connection blots with washers and butterfly nuts all made of brass or copper.
SUBHEAD XXIV : LIGHTING PROTECTION SYSTEM
Providing maintenance free Earth station with consisting of
- 40mm dia, standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, seald at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5mtrs.
- Earth Enhaced compound up to a depth of 2.0meters around the electrode capsule.
- Brick chamber & CI Cover complete.
Supply and laying of following size earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories when laid on the parapet with necessary interconnections with earth station and equipments.
25X 5mm GI Strip laid in Ground
32 X 5mm Aluminium strip conductor with DMC Insulated Supports
32 X 5mm Aluminium strip conductor with DMC Insulated Supports & including PCC Blocks.
Supply and installation of vertical air termination with 40mm dia copper hollow sphere with spikes, fixed on 1000mm length 25mm dia Copper rod including PCC block and all fixing accessories.
SUBHEAD XXV : FIRE ALARM SYSTEM
Supply, fixing, testing and commissioning of the following number of Loops Microprocessor based analogue addressable type (UL approved) intrinsically safe networkable Fire Control panel with Zonal Indications, Zener barriers, Signal booster for network connectivity modules with Optic Fiber cable, patch cords and Fiber optic media converters for both sides of the panels along with automatic speech dialer facility and where ever is required and with Battery Power pack as per specifications.
Single loop with loop card
Supply and laying of twisted pair 2.5sq.mm shielded FRLS insulated copper conductor flexible wire through existing MS Conduit.
Supply and fixing of 25mm dia 16SWG MS conduit concealed/ Surface in wall/ Ceiling/ above false ceiling including painting with 2 coats of Red colour paint for exposed part and all fixing accessories/ materials
Supply, installation, testing and commissioning of analogue addressable type multi sensor (smoke/ Heat) photo electric detectors with base and LED indication lamp along with all fixing accessories.
Supply, installation, Testing and commissioning of Response indicators with LED Indication lamp along with all fixing accessories.
Supply, installation, testing and commissioning of Addressable Pull type Manual call stations with monitor module with all fixing accessories.
Supply, installation, testing and commissioning of addressable loop sounders with all fixing accessories.
Supply, installation, testing and commissioning of Fault Isolators along with all fixing accessories.
Supply, installation, testing and commissioning of Addressable control modules along with all fixing accessories.
Supply, installation, testing and commissioning of Addressable Monitor module along with all fixing accessories.
Supply, installation, testing and commissioning of weather proof type analogue addressable Manual call points with glass and hammer on Stand post made out of 1500 mm long 50x50x6mm Galvanised channel fixed in ground with concrete coping as required.
Supply, installation, testing and commissioning of 8 Way Wago/ Phonix terminal connector in weather proof MS Junctionbox including painting and all installation materials etc as required.
Supply, installation, testing and commissioning of 2.5 Km range Siren with Weather proof motor with 220V 50HZ AC Supply operation with required power contactor, MPCB for control all in a weather proof enclosure near motor including all installation materials as required.
Supply and laying of 3 core 2.5sq.mm Copper conductor PVC insulated armoured cable in built up cable trench/ already laid RCC hume pipe or on cable tray with all installation materials for provison of power supply to Fire Alarm Panel, Repeater Panel, Siren, Exit signage's, Signalling modules etc complete.
Supply, installation, testing and commissioning of FLP Exit signage with wall/ Ceiling mounting fitting having 1.5 hrs backup, Non Maintained type - 1 x 11W CFL similar to that of PROLITE make - PEL 111 E / M ( Facia E 010 ) along with SLA Rechargeable Battery, 10 to 12 hrs Rechargeable Period, constant voltage charger. It shall confirm to IS 9583 - 1981, IP 20 protection, Battery duration +/- 10%, Red LED On indicating charging, equipped with Push to Test Switch, 22 SWG CRCA white powder coated housing, Input supply of 230 V AC 50 Hz single phase with including 16A Single Phase 250V Grade FLP Socket with switch. The size of the Facia shall be 350 mm(L) x 180 mm(W)x10mm(D).
Supply and laying of 50 mm dia dia. Class 'B' GI pipes for cable/wire protection below ground works.
SUBHEAD XXVI: DG SETS
Supply, Erection and commissioning of following 415V, 3phase 50HZ, 4 wire Radiator cooled DG sets with Accoustic Enclosure with out Electrical Control panel. The Diesel Engine shall be complete with necessary control and safety devices as per IS/ BS specifications. The Engine shall be suitable for continuous operation of Generator, inclusive of Flywheel, flexible coupling, air cleaner, corrosion resistor, Radiator, fan with guard, Fuel pump,fuel filter, Electronic governor, starting system with separate Battery charger with 2nos 24Vsealed low Maintenance Batteries, Voltage regulator, Instrument panel with RPM Indicator, Exhuast silencer (residential), protections against Low Lub.oil pressure, high water temperature and with standard capacity fuel tank suitable for 8hrs of Full load operation & Additional 990Ltrs tank with all pipe connections, fuel lines from Fuel tank to DG set, battery stand, anti vibration pads and first filling of lubricating oil and fuel oil for set. The Alternator shall be suitable for 415V 3phase, 4wire, 50HZ AC supply operation and shall be able to delivere full load.
MV Cables
Supply, testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable.The cable shall conform to IS 7098/ Part I.
3.5C X70 Sq.mm
Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUMEI METAL pipe as required.
Above 35 sq. mm and upto 95 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 kV grade as required.
3.5C X70 Sq.mm
Supply and Fixing of MS Exhaust Pipe of suitable size for following DG sets cladded with 50mm thick Glass wool insulation covered with 24SWG Aluminium sheet and provided with rain cap
Supply and fabrication of supports for Residential silencer/ exhaust pipe made out of MS channels/angles including cutting, welding and fabrication to the required size and painting with 2 coats of anti corrsoive paint and 2 coats of synthetic enamel paint of Gey/ Black colour complete as required
Supply, laying and commissioning of following size 1.1KV grade PVC insulated armoured multi strand copper conductor under ground cable,in built up cable trench/already laid RCC hume pipe or on cable tray with all installation materials.The cable shall conform to IS 1554/Part I.
7core 2.5sq.mm
3core 2.5sq.mm
Providing Double compression end terminations for the cable specified above with compression type steel gland, lugs using crimping tool, Insulation tape, Identification tags etc.,including end termination and Earthing of Gland.
7core 2.5sq.mm
3core 2.5sq.mm
SUBHEAD XXVII : ELECTRICAL POWER SUPPLY
HTSFU - Expansion (Expansion with 1no incomer & 1no outgoing)
Supply, installation, Testing and Commissioning of 11KV, 400A, 350MVA, Air break HTSFU with HRC fuses and earth switch.
HTSFU (out door type)
Supply, installation, Testing and Commissioning of 11KV, 400A, 350MVA, Air break HTSFU with HRC fuses and earth switch. (As Transformer Controlling Breaker).
TRANSFORMER
Supply installation Testing and commissioning of 11KV/433V following capacity Outdoor ONAN Copper wound Distribution Transformer with Off Circuit Tap changer as per detailed Technical Specifications.
HT Cables
Supply, testing and commissioning of following size 11KV XLPE insulated armoured aluminium conductor under ground cable.The cable shall conform to IS 7098/ Part II.
3C X 95 sq.mm
Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning,protective covering and refilling the trench etc. as required.
Upto 120 sq. mm.
Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 11 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 120 sq. mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in the existing masonry open duct as required.
Upto 120 sq. mm.
Providing Indoor Heat shrinkable end terminations for the cable specified above with all materials, lugs using crimping tool, 11KV Insulation tape, Identification tags etc., including end termination and Earthing of Gland.
3C X 95sq.mm Indoor type
MV Panels
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA/ Galvanised steel enclosure for main frame and 1.6mm thick partitions and shall have IK Certification as per IEC 62262 for mechanical strength / ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below.The panel shall be got fabricated from manufacturers as per IEC 61439(Part-1&2). Indoor panels shall have IP-4X degree of protection and outdoor panels shall have IP-55 degree of protection wiith external door. Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose.
The PCC shall have at least two spare cubicles. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. All MCCBs of rating 160A and above shall be with Micro processor releases All MCCBs below 160A shall be with adjustable thermal magnetic based releases. All MCCBs shall be with spreader links and rotary handle. All MCCBs shall be over load & short circuit releases with Icu=100% Ics. All CTs/CBCT shall be resin cast type. All Controlling wiring shall be FRLS cables, all the bus bar sleeves shall be Heat shrinkable kits. Panels shall have form 4b/form 3b construction as per the requirement. ACBs shall conform to IEC 60947 (part 1&2), shall be suitable for rated system voltage 690V, Insulation voltage 1000V and Impulse withstand of 12KV.
Sub station panel
EB & DG Incoming :
200A, 35KA 4pole MCCB with O/C, S/C & ELR with CBCT & 200A FP Power contactor - 2sets
Busbars :200A TPN Aluminium busbars - 1 set
(Neutral shall be 100% Phase busbar)
Outgoings :
160A 35KA TP+NL MCCBs – 2no
40/63A 10KA TP+NL MCCBs – 3nos
65A AC1 Contactor with 230V Coil and a Time
Switch similar to L&T TSQ 100 -1set
20A 10KA TP+NL MCBs -6nos
40A 10KA DP MCBs - 2nos
40A,25KA TPMCCB with suitable capacitor duty rating Contactor and 10 KVAR MPP 440V Delta connected heavy duty Capacitor Banks -1nos
40A,25KA TPMCCB with suitable capacitor duty rating Contactor and 5 KVAR MPP 440V Delta connected heavy duty Capacitor Banks -2nos
40A,25KA TPMCCB with 5 KVAR MPP 440V Delta connected heavy duty Capacitor Banks -1no (fixed)
63A,35KA FP MCCB with TVSS - 1set
Metering :
LED Phase indication lamps with individuals Fuses and control with toggle switches-2sets
CT Operated Load manager with RS485 port (Similar to EM-6400) – 2sets
Resin cast CTs of ratio 200-100/5A, Class 1 Accuracy and 15VA burden on R phase for APFCR -1no
Note : Mechanical & Electrical Interlocking shall be provided between two incomers
MV Cables
Supply, testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part I.
3.5C X 70 Sq.mm
Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Above 35 sq. mm and upto 95 sq. mm
Laying of one number additional PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUMEI METAL pipe as required.
Above 35 sq. mm and upto 95 sq. mm
Supplying and fixing cable route marker with 10 em X 10 em X 5 mm thick G.l. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Providing Indoor ordinary end terminations for the cable specified above with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc.,
3.5C X 70 Sq.mm
RMK Projects
ELIXIR MET FORM PRIVATE LIMITED
Sri Raghava Constructions Limited
SSC PROJECTS PRIVATE LIMITED
SREE LAKSHMI CONSTRUCTIONS
SAI CONSTRUCTIONS
Hi-Tech Infrastructure
DARSHAN CONSTRUCTION Co.,
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .