| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC 22 319 GALI NO 5 MAHABIR PARK BAHADURGARH 124507 HARYANA | JHAJJAR | HARYANA | 124507 | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹25.6 L+₹16,397 (0.64%)Rejected-AOC | L2 | Rejected-AOC Bidder not quoted L1 rates | |
| 3 | L3₹29.1 L+₹3.7 L (14.3%)Rejected-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-AOC Bidder not quoted L1 rates | |
| 4 | L4₹29.9 L+₹4.4 L (17.4%)Rejected-AOC | L4 | Rejected-AOC Bidder not quoted L1 rates | |
| 5 | L5₹32.7 L+₹7.2 L (28.4%)Rejected-AOC | L5 | Rejected-AOC Bidder not quoted L1 rates |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
9 Feb 2022, 6:00 pmClosed
GE SOUTH PUNE
NO 1 GENERAL BHAGAT MARG PUNE 411040
8319 REPAIR / REPLACEMENT / MAINT SUB MAIN WIRING, FITTING, EARTHING, INTERNAL WIRING, CEILING FAN, GEYSER AND CERTAIN MISC WORK IN AREA No. 1 AND OTHER CONNECTED AREA UNDER AGE EM SOUTH PUNE
2022_MES_500522_1
8319 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
273 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹78,000
17 Mar 2022
10 Jan 2022
11 Feb 2022
10 Jan 2022
9 Feb 2022
27 Jan 2022
Amount
Notes for item Nos. 2 to 105 below : (a) One electrician to be present daily to attend complaint and carry out other works as per CA. (b) If found absent three times the minimum wages will be deducted for the day of absentees. (c) Attending complaints and carry out other repair works as per CA has to carry out in COVID hospital at AICTS, ALC and CHSC where Electrician with helper has to go inside COVID WARD where COVID positive patients are treated if complaints are not attended five times the minimum wages of Electrician and helper will be deducted till complaints are not attended and Decision of GE is final and binding.
Taking down carefully exising unserviceable aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making good disturbed surfaces of wall, floor etc. complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLS- flexible wiring cable conforming to IS: 694-1990 PVC insulated, unsheathed copper conductor cable with tripple layers protection Make:- Finolex/Polycab/ Havell's drawn through in and including heavy duty , PVC concealed conduit of white/ ivory colour including all accessories after cutting chasing in wall of any type /ceiling etc, heavy duty ISI marked, with GI sunken boxes with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches of Make- Legrand ( Myrius ) or equivalent including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One bell point controlled by one, bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Sr. Item No 3.00 above but using 2.5 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sqmm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with GI sunken /surface boxes with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches of Make- Legrand ( Myrius ) or equivalent or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One bell point controlled by one, bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Sr. item No 5.00 above but using 2.5 sqmm single core copper conductor FRLS cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with mild steel sunken boxes with earth dolly duly, covered with hylem sheet cover 3 mm thick, ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 7 above but using 2.5 sqmm copper conductor for with 2.5 sqmm earth wire one 6 pin 15 amps socket outlet on independent board all as specified and directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLS- flexible wiring cable conforming to IS: 694-1990 PVC insulated, unsheathed copper conductor cable with tripple layers protection Make:- Finolex/Polycab/ Havell's drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after cutting chasing in wall of any type /ceiling etc, with mild steel sunken boxes with earth dolly duly, covered with hylem sheet cover 3 mm thick, suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 9 above but using 2.5 sqmm copper conductor for with 2.5 sqmm earth wire one 6 pin 15 amps socket outlet on independent board all as specified and directed.
S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and as directed.
S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified and as directed.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F for Modular Switch Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and as directed.
S & F for modular step type fan regulator 100 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
S & F for Bell push modular 6 Amps single module complete all as specified and as directed.
S & F in repair modular plate with frame 4 modules complete all as specified and as directed.
S & F in repair modular plate with 6 modules complete all as specified and as directed.
S & F in repair modular plate with 8 modules complete all as specified and as directed.
Supply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ AC supply complete all as specified and as directed.
S&F lamp holder insulated body with back plate PVC/Polycarbonate type with cord grip cap, angular type fixed on wall complete all as specified and directed.
S & F for Ceiling rose, surface Bakelite suitable ISI marked for batten fitting complete all as specified and as directed.
S & F for Switch piano flush type, single pole, one way, and 6 Amp complete all as specified and as directed.
S & F for Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, piano flush type complete all as specified and as directed.
M&L for switch piano flush type, 15 Amps single pole one way complete all as specified and as directed.
S&F in replacement of socket outlet flush type 2 in 1, 3 pin , 6 and 15 Amps fixed and connect in existing board complete all as specified and as directed.
Supply and fixing ceiling fan regulator, electronic, step type, rotary 0 to 04 steps, hum free, AC, 230 volts, duly ISI marked fixed and connect in existing board complete all as specified & directed.
S & F in replacement of switch piano flush type push button for call bell 5 Amps complete all as specified and as directed.
S&F in replacement IP-43, protection metal door Vertical TPN -DB rated busbar, pan assembly etc. with interconnection links, blanking plates, cable ties, identification labels TPN 4 way, 12 modules with provision to mount 100 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed/fixed on wall/board as required including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make (Make :- L&T (DBVTL004DD) or Equivalent in Legrand / HPL (O safe) )
S&F in replacement MCCB 4 pole 100 Amp, Icu = 16 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts bolts and washers for proper connections all as specified and directed. (Make : L&T (CM90518OOKO) or Equivalent in Legrand / HPL (O safe ) )
S&F in replacement,IP-43 ,MCB DB TPN 4 way ,double door, with busbar 415 V, and concealed/fixed on wall/board as required including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make complete all as specified and as directed.
S&F in replacement,IP-43 ,MCB DB 12 way ,double door, with 100 amp rated busbar 240 V, SPN and concealed/fixed on wall/board as required including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make complete all as specified and as directed. (Make- L&T (DBSPN012DD) or of equivalent in Legrand / HPL (O safe) )
S&F in replacement,IP-43 ,MCB DB 8 way ,double door, with 100 amp rated busbar 240 V, SPN and concealed/fixed on wall/board as required including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make complete all as specified and as directed. (Make- L&T (DBSPN008 DD) or of equivalent in Legrand / HPL (O safe) )
S&F in replacement,IP-43 ,MCB DB 4 way ,double door, with 100 amp rated busbar 240 V, SPN and concealed/fixed on wall/board as required including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make complete all as specified and as directed. (Make- L&T (DBSPN004 DD) or of equivalent in Legrand / HPL (O safe) )
S&F in replacement,Metal plug and socket -2 pin with 20Amps concealed/fixed in wall as required including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc as required to the disturbed surfaces to match the existing Make complete all as specified and as directed. (Make- L&T (DBMPS220SD) or of equivalent in Legrand / HPL (O safe ) )
S&F in replacement MCB SP 6-40 Amps,10KA,'C' series complete all as specified and as directed.
S&F in replacement MCB SPN 20-40 Amps,10KA, 240V,'C' series complete all as specified and as directed.
S&F in replacement MCB TP 32/40 Amps, 10KA, 415 V, 'C' series complete all as specified and as directed.
S&F in replacement MCB TPN 40 /63 Amps, 10KA, 415 V, 'C' series complete all as specified and as directed.
Supply & fix LED tube light 20 Watt 4 fit long, T-8 rectrofit tube including taking down tube light and choke from any type fitting and making all connection all as specified and directed.
Supply & fix in repair recess mounting LED down light fitting 18/ 20 Watt natural white complete as per existing size repairs/making good the pop/gypsum ceiling with good finish as existing with suitable fixing arrangement connection complete all as specified and directed.
M & L for LED pannel Recess mounted -2'x2' - 36 watts light fitting with build in PIR OCCUPANCY SENSOR OFFERING FLEXIBLITY OF AUTO SWITCHING OFF WHEN THE SPACE NOT OCCUPIED complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting complete all as specified and as directed. (Make - Philips RC383B LED 36 S-6500 PSU OD WH PIPR or equivalent of Havells/HPL/WIPRO/Bajaj)
M & L for LED panel Recess mounted -2'x2' - 36watts light fitting with heat exchanger unit complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting complete all as specified and as directed. (Make- WIPRO ( CRCO10R038HP57GL1 ) or equivalent of HPL/ /Havells/PHILIPS/Bajaj)
Supply and fix LED tube light fitting complete with all fitting and fixing accessories, 1X20Watt pre-wired with high efficiency electronic driver, glare free, smooth light distribution complete including taking down any type fitting all as specified and as directed. (Make- Havells E-Lite pride plus or of equivelent in Wipro / HPL / Bajaj)
Supply & fix LED batten Color changing fitting 20Watts complete all as specified and directed including taking down existing FTL complete all as specified and as directed.
S&F wall mounting fancy light fitting with polycarbonate cover complete with all accessories (connector block, lamp holders) with 9 Watts LED lamp incl taking down any type old fitting complete all as specified and directed (Make : Havells ( city -3 ) or equivalant make of Bajaj/ HPL/Wipro)
Supply & fix in repair recess mounting LED down light fitting 10/12 Watt natural white complete as per existing size repairs/making good the pop/gypsum ceiling with good finish as existing with suitable fixing arrangement connection complete all as specified and directed.
Supply & fix LED tube fitting 10 Watts complete all as specified and directed including taking down existing holder all as directed.
Supply and replace suitable driver for LED down light fitting 18 /20 Watts of the existing make good in a suitable way disturbed area as existed complete all as specified and directed
Supply & fix LED tube 5 Watts complete all as specified and directed including taking down existing holder complete all as specified and as directed.
Supply & fix LED tube light fitting 20 Watts with alumanium extrusion housing in cluding taking down any type fitting complete all as specified and as directed.
Supply and replace suitable driver for LED pannel Recess mounted -2'x2' - 36 watts of the existing make in a suitable way and including making good the disturbed area as existed complete all as specified and directed
Supply and replace suitable driver for LED tube fitting 18 /20 Watts of the existing make in a suitable way complete all as specified and directed.
Taking down carefully all type of sub main wiring any core including batten / conduit and making good to disturbed surface as matching to existing complete all as specified and directed.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 06 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note :- One meter of conduit along with 2x6 sq mm wire and one 6 sq mm earth shall be measured as one unit length)
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 04 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note:-One meter of conduit along with 2x4 sq mm wire and one 4 sq mm earth shall be measured as one unit length)
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 04 Sqmm nominal cross sectional area,1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI mark PVC casing caping including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note :- One meter of PVC casing caping along with 2x4 sq mm wire and one 4 sq mm earth shall be measured as one unit length.)
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 06 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable Make:- Finolex/policab/ Havell's and including ISI mark PVC casing caping including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note :- One meter of PVC casing caping along with 2x6 sq mm wire and one 6 sq mm earth shall be measured as one unit length)
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size with 06 Sqmm nominal cross sectional area,multi core core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- flexible wiring cable conforming to IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, with two single core, PVC insulated, copper conductor cable drawing into and including rigid non metalic PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note :- One meter of conduit along with 4 x 6 sqmm wire and 2 x 6 sqmm earth shall be measured as one unit length.)
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size with 06 Sqmm nominal cross sectional area,multi core core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- flexible wiring cable conforming to IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, with two single core, PVC insulated, copper conductor cable drawing into and including ISI mark PVC casing caping including fitting fixed onwall /ceiling etc of suitable size connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note :- One meter of Casing Capping along with 4x6 sqmm wire and 2 x 6 sqmm earth shall be measured as one unit length.)
S&F LED LAMP 9 Watts pin type including taking any type of lamp complete all as specfied and directed.
Supply & fix in repair existing fan Condenser 2.5 mfd 230 Volts complete all as specified and as directed. (Make :-Havells / Epcos/Havells /Siemens)
Supply & fix in repair existing fan Condenser 4 mfd 230 Volts complete all as specified and as directed. (Make :-Havells / Epcos/Havells /Siemens)
S&F in replacement of burnt out and unserviceable fan motor assembly complete including double bearing, copper windng with metal plate top & bottom side suitable for 1200mm sweep in any existing make complete all as specified and as directed.
M & L for Attending emergent complaints i.e No light , Earth leakage, Short Circuit, Neutral break mains /sub mains/internal circuits of existing system of main building / block ,making continuous electric supply including carrying out minor repairs etc as required to Make- the system in order / functional including replacing fuse wire, copper cable, copper thimbles, glands, earthing wire by providing one electrician and one helper in the complete area of residential area round the clock for and including Sundays and Holidays complete in working hours as decided by the MES and maintaining proper complaint register and upkeeping complaint slips duly signed by JE E/M and checked by Engineer in charge all as specified and directed (Note :- Rate of Fuse wire, copper cable, copper thimbles, glands, earthing wire are deemed to be considered in this item 2. Minimum One electrician to be present daily during the contract period, if found absent Rs-1600 will be deducted daily)
Supply and replace anchor bolt & nut 8mm dia of the geyser in a suitable way and making good the distrubed area complete all as specified and as directed.
Supply only Self adhesive PVC electrical Insulation tape 7 mtr long with superior quality, ISI Marked complete all as specified and as directed.
Supply and replace hylem sheet as existed in the Switch boad making provision for fixing switches and socket complete all as specified and as directed.
Taking down fans, removing to workshop for servicing, cleaning, lubricating, replacement of split pin, rubber bush and other spare required if any including fixing PVC cable with stranded copper conductor of size 0.75 Sqmm and refixing the fans at the same locations complete all as specified and as directed. (Note:- Spares like , bearing, terminal connector, gun metal bush, PVC cable shall be measured and paid seperately as supply only)
Ceiling fans of any size
Exhaust fan of any size
Wall mounting fan of any size
Supply only the following spare parts :-
Bearing 6200 to 6203 ZZ Make - SKF/NBL
Conductor Terminal 3 way Bakelite
Supply only brass gun metal bushing suitable of size 1200/1400mm sweep ceiling fan complete all as specified and as directed.
Supply and Fix in replacement canopy for ceiling fans (Set of two) complete all as specified and as directed.
Supply and Fix in replacement MS clamp with rubber reel, nuts, bolts, split pin etc suitable for 1200/1400 mm sweep ceiling fan complete all as specified and as directed.
Supply and replace fan blade (set of 3) suitable for 1200 mm of existing make complete all as specified and as directed.
M&L for replacement of burnt winding of fans, rewinding complete with super enamelled copper wire of same guage and weight, replacement of insulation paper, varnishing, heating up and testing complete including taking down and refixing the fan at positions to the satisfaction of Engr-in-charge for the following :-
Ceiling fan 1200/1400mm sweep working on 230 volts AC supply
Exhaust fan upto 300/450 mm sweep working on 230 volts AC supply
Wall mounting fan of any 230/450 mm size,working on 230 volts AC supply
S&F in replacement downrod for ceiling fan made out of GI pipe medium grade 15mm dia with fan clamps incl drilling cutting threding etc all as directed for ceiling fan 1200/1400 sweep of following sizes:-
2 ft long
4 ft long
6 ft long
Taking down geysers carrying to workshop for repairing, servicing, cleaning etc, replacement of thermostat, heating element, indicator lamp and thermal cut out incl fixing of PVC cable, sheathed, three core with stranded copper conductor of size 2.5 sqmm and refixing the geysers at location for :- (Note :- Heating element, thermostat indicator lamp & thermal cutout etc shall be measured and paid separately as supply only)
25 litres capacity
50 litres capacity
Supply only heating element 2 KW, 230 volt round/ triangular in shape ISI marked complete all as specified and as directed.
Supply only heating element 1.5 KW, 230 volt round/ triangular in shape ISI marked complete all as specified and as directed.
Supply only heating element 1 KW, 230 volt round/ triangular in shape ISI marked complete all as specified and as directed.
Supply only Indicating lamp (red/green/yellow) complete suitable for 25/50/100 liters capacity geyser complete all as specified and as directed.
Supply only thermostat ISI marked complete suitable for 25/50 liters capacity geyser complete all as specified and as directed.
M&L for spray painting of old surface of fan / Exhaust fan / Pedestal fan of any description by applying one coat of synthetic enamel paint complete including taking down and refixing with writing MES Nos. and preparation of surfaces complete all as specified and directed .
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
All as per Sr. Item No. 84.00 above but size of conductor 2.5 Sqmm complete.
All as per Sr. Item No. 84.00 above but size of conductor 4 Sqmm complete
All as per Sr. Item No. 84.00 above size of conductor 6 Sqmm complete.
Supply and fixing in repairs PVC fresh air fan 300mm with louvers complete all as specified and as directed.
Supply and fixing in repairs PVC fresh air fan 250mm with louvers complete all as specified and as directed.
Supply and fixing in repairs PVC fresh air fan 200mm with louvers complete all as specified and as directed.
Supply & fix in replacement 15A plug top and connection complete all as specified and as directed
Supply & fix PVC connections pipe with brass hexagonal adapters both side suitable for 15mm bore pipe 45/60cm long for cold water as per requirement complete all as specified and as directed
Supply & fix PVC connections pipe with brass hexagonal adapters both side suitable for 15mm bore pipe 45/60cm long for hot water as per requirement complete all as specified and as directed
S&F in repairs cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100V grade from socket/switch to geyser complete all as specified and as directed.
S&F in repairs cable PVC insulated 3 core 4.0 Sqmm with stranded copper conductor 1100V grade complete all as specified and as directed.
Supply and replace flat twin 4 Sqmm with aluminium conductor multi strand black cable as per IS 694-1990 all as specified and directed
Supply and replace flat twin 6 Sqmm with aluminium conductor multi strand black cable as per IS 694-1990 complete all as specified and as directed.
Supply and Fix LED bldg light 25Watts in aluminium housing with glass cover with suitable dia GI pipe bend to shape existing including taking down existing any type security light all as specifed and directed. (Make -Havells Endura Pearl or equivalent in Bajaj/HPL/WIPRO)
Supply and Fix LED security light 35/36 Watts in aluminium housing with glass cover with suitable dia GI pipe bend to shape existing including taking down existing any type security light all as specifed and directed. (Make - Jaguar (PCR ) equivalent in Havells / Bajaj / HPL/Wipro)
Supply and Fix post top lantern 70 Watts including taking down existing any type of fitting complete all as specified and as directed. (Make - Bajaj (Celesta ) or equivalent in Havells/HPL / WIPRO)
Supply and Fix post top lantern 35/40 Watts including taking down existing any type of fitting (Make - Bajaj (Arian) or equivalent in Havells / HPL /WIPRO)
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. (Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.)
Disconnecting and dismantling online UPS of upto 15 KVA capacity and removing all the cleaning and removing moisture from ups present in it and testing of self diagnostic with on load testing and refixing the same it position complete all as directed. (Note - the UPS will be tested and checked by authorised technition and visiting charges for technitian is deemed to be included in the quoted rate.)
S&F in replacement MCCB 4 pole 125 Amp, Icu = 18 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts bolts and washers for proper connections complete including MS enclosure of suitable size all as specified and directed. (Make :- L&T (CM90996OOOO) or Equivalent in Legrand / HPL (O safe))
S&F in replacement MCCB 4 pole 200 Amp, Icu = 18 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts bolts and washers for proper connections complete including MS enclosure of suitable size complete all as specified and directed. (Make :- L&T (CM91003OOOO) or Equivalent in Legrand / HPL (O safe) )
M R ENTERPRISES
metro electrical services
RAJKUMAR KISHANCHAND JASWANI
AMAN ENGINEERING AND ELECTRICAL WORKS
ASHWAMEDH ENGINEERS
SUNIT TRADING CORPORATION
M/S - SUJIT ELECTRICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .