| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.7 CrAdmitted-Finance B1 114 CHAND BIHARI NAGAR KHATIPURA ROAD JAIPUR RAJASTHAN 302012 | JAIPUR | RAJASTHAN | 302012 | -3.13% | ₹1.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.7 Cr+₹4.8 L (2.90%)Admitted-Finance | -2.11% | ₹1.7 Cr+₹4.8 L (2.90%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s R R Refrigeration And Electricals L2 | TAPANUKULA PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| .01NON BSR ITEM | |||||
| 1.00Supply, installation, testing and commissioning of Outdoor Units with Scroll compressor, copper condenser and required accessories for connnecting with AHU with R-407C/ R-410 Refrigerant Complete with Controller alongwith Thermostat, Potential free Contacts for Remote Operation etc. | |||||
| 1.01 | 11 TR in Twin ckt (2X5.5 Tr) | 3 | Set | 2,13,050 ₹6,39,150 Lowest | 3,00,000 ₹9,00,000 |
| 2.00Supplying, installing, testing and commissioning of double skin construction Air Handling Units as per specification. AHU's shall be draw thru type, complete with pre & fine filter section including Filter, minimum 6 row deep DX coil of copper tube & aluminium fins, flexible duct connection, squirrel cage induction motor, DIDW backward curve fan(s), belt drive, vibration isolators and mixing box for return air, fresh air. Fan Motor shall be suitable for 415±10% volts, 50 Hz, 3 phase AC supply and shall be high efficiency (IE-2 Class). AHU shall be selected for a maximum coil of 500 FPM and filter face velocity of 350 FPM. The AHU inner skin shall be 0.6 mm pre coated GI, outer skin shall be 0.6 mm pre coatd GI, The AHU panel shall be 25mm thick 40 Kgf PUF insulation with thermal break profile, The AHU shall be complete with AHU kit of following capacities. | |||||
| 2.01AHU (CFM) TYPE RD SP (mm) PHASE | |||||
| 2.02 | 4400 FM 6 100 3 | 3 | Nos. | 2,42,300 ₹7,26,900 | 2,34,080 ₹7,02,240 Lowest |
| 3.00 | Supply, installation testing, commissioning and validation of Laminar Flow Units (LFU) comprising of Terminal EU 13 HEPA Filters of 99.997% Efficiency down to 0.3 Micron particle size installed in zero leakage Al frame with Al perforated plate type Al grille, LFD laminar flow diffusers are constructed from 18 swg aluminium
sheet, perforated face with approx. 50% perforation of size 900x600mm-6nos, 600x600mm-3nos, including the cost of supply air 18 gauge Al plinum of size 8'x6'x2', including all connection complete in all respect. | 3 | Each | 1,38,900 ₹4,16,700 | 1,20,000 ₹3,60,000 Lowest |
| 4.00 | SITC of Heat recovery ventilation system of 1000 CMH for better indoor air quality with exhaust and fresh air supply and return duct connection with enthalpy wheel of . | 3 | EAch | 1,20,500 ₹3,61,500 | 60,000 ₹1,80,000 Lowest |
| 5.00 | Providing and fixing of VFD of required ratings for 5000 CFM AHU with extendable sensor for giving control through surgen control panel | 3 | Nos. | 97,580 ₹2,92,740 | 32,000 ₹96,000 Lowest |
| 6.00 | SITC of 1000 CFM capacity Circular duct fans(Inline Fans) of 1 phase ,230volt, 50 Hz, various capacity, Sound pressure level at 3 m : 53db, Insulation class of motor : B class, Enclosure class of motor : IP44 etc. complete in all respect of. | 3 | Nos. | 14,800 ₹44,400 Lowest | 16,000 ₹48,000 |
Tender Value
₹1.8 Cr
EMD Value
₹3.5 L
Closing Date
19 Aug 2026, 6:00 pmClosed
Executive Engineer M and H, Dn. 2 Jaipur
Executive Engineer M and H, Dn. 2 Jaipur
SITC of Air Conditioning work 50 Bedded Satelite Hospital Pathviraj Nagar.Distt Jaipur.
2026_MEDIC_583645_6
NIT No.12/2026-27EEM and HDiv 2 Jaipur/
Open Tender
Electrical Works
Percentage
365 days
Jaipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
RTGS/NEFT/Any other money Transfer System
₹3.5 L
18 Sept 2026
7 Aug 2026
20 Aug 2026
7 Aug 2026
19 Aug 2026
7 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
| 1.01 | 1.5 TR ISEER not less then 4.6 | 25 | Each | 58,329 | ₹14,58,225 |
| 1.02 | 2.0 TR ISEER not less then 4.6 | 16 | Each | 67,783 | ₹10,84,528 |
| 2P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 2.01 | 4.0 Sq.mm 3 core flat / Round | 400 | Mtr | 214 | ₹85,600 |
| 3 | SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | 200 | Kg | 1,987 | ₹3,97,400 |
| 4Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
| 4.01 | a) 25 mm | 180 | Mtr. | 229 | ₹41,220 |
| 4.02 | 20 mm | 200 | Mtr. | 189 | ₹37,800 |
| 5Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 5.73 MB
Tendernotice_2.pdf
PDF • 7.44 MB
Tendernotice_3.pdf
PDF • 2.69 MB
Tendernotice_4.pdf
PDF • 0.07 MB
Annexure-A-BSR-2022.pdf
Tender Documents • 0.26 MB
Special-TandC-for-Electrical-work--Annexure-C---3-.pdf
Tender Documents • 0.35 MB
T-and-C-for-Electrical-work-DLP--Annexure-B---3-.pdf
Tender Documents • 0.24 MB
BOQ_1036724.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .