Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹27.8 L+₹9,437.70 (0.34%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹27.8 L+₹11,337.65 (0.41%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹28.3 L+₹57,582.25 (2.08%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹29.7 L+₹2.0 L (7.22%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/s logitech solution L10 | Neha Enterprises L9 | Raj Contruction L8 | City buildcom builders & devlopers L5 | PRAGATI ELECTRICALS AND ELECTRONICS L3 | AJIT ENTERPRISES L6 | SULTAN SINGH, CONTRACTOR L4 | SHIV SHANKAR MISHRA L1 | Neelam Traders L7 | MODI CORPORATION L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline | |||||||||||||
| 1.10 | Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc or for manholes, laying of pipe lines, cables, pipes etc in any type of soil and getting out complete all as specified and directed. | 137.05 | Cum | 250 ₹34,262.5 | 250 ₹34,262.5 | 220 ₹30,151 | 220 ₹30,151 | 200 ₹27,410 | 230 ₹31,521.5 | 80 ₹10,964 Lowest | 300 ₹41,115 | 250 ₹34,262.5 | 200 ₹27,410 |
| 2.00 | Returning filling in, including spreading, leveling watering & well ramming in layers not exc 25 cm thick complete all as specified and directed. | 123.35 | Cum | 80 ₹9,868 | 35 ₹4,317.25 | 80 ₹9,868 | 80 ₹9,868 | 80 ₹9,868 | 90 ₹11,101.5 | 60 ₹7,401 | 30 ₹3,700.5 Lowest | 90 ₹11,101.5 | 75 ₹9,251.25 |
| 3.00 | Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and diected. | 13.71 | Cum | 90 ₹1,233.9 | 45 ₹616.95 | 90 ₹1,233.9 | 90 ₹1,233.9 | 200 ₹2,742 | 95 ₹1,302.45 | 60 ₹822.6 | 35 ₹479.85 Lowest | 100 ₹1,371 | 80 ₹1,096.8 |
| 4.00Taking out existing CI/DI pipe line, of any class including CI fitting with spigot and socket ends and lead joints including burning out lead joints, recovering lead for re-use complete all as specified and directed for the following sizes :- | |||||||||||||
| 4.01 | (a) 80mm bore | 228 | RM | 30 ₹6,840 | 20 ₹4,560 Lowest | 30 ₹6,840 | 30 ₹6,840 | 30 ₹6,840 | 45 ₹10,260 | 50 ₹11,400 | 80 ₹18,240 | 35 ₹7,980 | 50 ₹11,400 |
| 4.02 | (b) 100 mm bore | 158 | RM | 35 ₹5,530 | 25 ₹3,950 Lowest | 35 ₹5,530 | 35 ₹5,530 | 35 ₹5,530 | 45 ₹7,110 | 60 ₹9,480 | 100 ₹15,800 | 40 ₹6,320 | 60 ₹9,480 |
| 4.03 | (c) 150 mm bore | 184 | RM | 40 ₹7,360 | 35 ₹6,440 Lowest | 40 ₹7,360 | 40 ₹7,360 | 70 ₹12,880 | 55 ₹10,120 | 70 ₹12,880 | 120 ₹22,080 | 45 ₹8,280 | 80 ₹14,720 |
| 4.04 | (d) 200 mm bore | 108 | RM | 95 ₹10,260 | 60 ₹6,480 Lowest | 95 ₹10,260 | 95 ₹10,260 | 100 ₹10,800 | 105 ₹11,340 | 80 ₹8,640 | 150 ₹16,200 | 100 ₹10,800 | 100 ₹10,800 |
| 4.05 | (e) 250 mm bore | 156 | RM | 125 ₹19,500 | 80 ₹12,480 Lowest | 125 ₹19,500 | 125 ₹19,500 | 110 ₹17,160 | 130 ₹20,280 | 100 ₹15,600 | 200 ₹31,200 | 125 ₹19,500 | 150 ₹23,400 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
1 Sept 2025, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR REPLACEMENT OF EXTERNAL WATER SUPPLY PIPELINES VALVES AND CONNECTED ACCESSORIES AT OTM ACCN AT BAIRAGARH UNDER GE BHOPAL
2025_MES_725729_1
8431/E8
Open Tender
Civil Works - Water Works
Item Rate
274 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹80,000
Yes
15 Dec 2025
12 Aug 2025
3 Sept 2025
12 Aug 2025
1 Sept 2025
27 Aug 2025
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc or for manholes, laying of pipe lines, cables, pipes etc in any type of soil and getting out complete all as specified and directed.
Returning filling in, including spreading, leveling watering & well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and diected.
Taking out existing CI/DI pipe line, of any class including CI fitting with spigot and socket ends and lead joints including burning out lead joints, recovering lead for re-use complete all as specified and directed for the following sizes :-
(a) 80mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 to 450 mm bore
Relaying CI pipe including fittings with spigot and socketed end/ flanged end, centrifugally cast laid in trenches after cleaning internally and externally, drawing out foreign material/ rust complete and jointing with and including new titon joints for fixing of pipe complete all as specified and directed for the following sizes:- Note :- (i) Earth work, joints and CI specials/fittings of the pipes shall be measured and paid separately under appropriate item.
(a) 80mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 to 450 mm bore
Supply, laying and jointing of DI iron pipes SS class K-9 of standard length with internal cement mortar coating and external surface with bituminious paint, ISI marked including nuts, bolts, packing material etc; and making the joint leak proof complete all as specified and directed for the following sizes:- Note : - Earth work, joint and CI/DI specials/fittings of the pipes shall be measured and paid separately under appropriate items of schedule.
(a) 100 mm bore
(b) 150 mm bore
(c) 200 mm bore
(d) 250 mm bore
S&F push on flexible rubber gasket (Tyton) joint complete all as specified and directed suitable for following sizes :-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 450 mm bore
Cutting of cast iron pipes in position for insertion of new tees, branches, etc; comprising of two cuts complete all as specified and directed for the following sizes:-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 450 mm bore
S&F of CI/DI, bend (any type, radius and angle) tapers any type, straight bend including decreasing or double socket etc, Tee pieces single branch, 'Y' junction, all sockets or socket and spigot or flanged, collars, caps and plugs for spigot socketed pipes of upto 150 mm bore complete all as specified and directed.
S&F of CI/DI, bend (any type, radius and angle) tapers any type, (straight bend including decreasing or double socket etc) Tee pieces single branch, 'Y' junction, (all sockets or socket and spigot or flanged) collars, caps and plugs for spigot socketed pipes of 200 to 450 mm bore complete all as specified and directed.
M&L for cutting floor/ PCC/ footpath of 20 cm width and 90 cm depth as required for re-laying/ laying of cable/pipe etc. and making good by filling earth and 150 mm thick PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) at the top to match the level as per site requirement complete all as specified and directed.
M&L for run lead joint for spigot and socketed end CI pipe & fittings including excavation, returning and refilling complete all as specified and directed for following:-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 to 450 mm bore
M&L for cocking of run lead joint for spigot and socketed pipes and fittings including excavation, returning & refilling etc complete all as specified and directed of following sizes:-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 to 450 mm bore
M&L for taking out sluice valve top cover, repairing of unserviceable spindle and unserviceable check nut by grinding, machining and putting extra material with and including required lath work and refixing of sluice valve parts after servicing including replacment of gland packing, rubber sheet, nuts, bolts, check nut and washer of existing size complete all as specified and directed of following sizes:-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 to 450 mm bore
S&F in replacement new cast iron flanged sluice valve of class PN 1.0, long body, ISI marked, confirming to IS-14846 with stainless steel spindle and hand wheel including nuts, bolts, rubber gasket for installation of valve complete all as specified and directed of following sizes:-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
M&L for framed work for made of angle iron, MS sheet as required including welding, cutting, providing hinges, locking arrangments including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for brick work with sub class B bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 complete all as specified and directed.
M&L for PCC, 1:2:4, type B1 (using 20 mm graded stone aggregate) as in copping/ support and similar work including necessary form work etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work, finished even and smooth without using extra cement complete all as specified and directed.
Taking down existing steel tubing and connections with fittings complete all as specified and directed of following sizes:-
(a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 mm bore
(e) 50 mm bore
(f) 80 mm bore
Refixing retrived old steel tubing and connections in new or old position including cleaning internally and externally any grade/make, laid in trenches/ floor or fixed to walls with and including new fittings such as sockets, tee, union elbow etc complete all as specified and directed of follwing sizes:-
(a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 mm bore
(e) 50 mm bore
(f) 80 mm bore
S&F of GI tubing, medium grade, ISI Marked in any length including cutting, threading, making connection in new or old position with and including and all type of GI new fittings for laid in trenches/wall/floor complete all as specified and directed of following sizes:-
(a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 mm bore
(e) 50 mm bore
(f) 80 mm bore
S&F of 3 layer PP-R poly propylene random complymer concealed pipes (outer diameter of pipe) SDR 7.4 (PN-16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain brass threaded polypropylene random fittings fixed to walls, ceilings or laid in floors complete all as specified and directed of following sizes :-
(a) 20 mm outer dia
(b) 25 mm outer dia
(c) 32 mm outer dia
S&F of 3 layer PP-R poly propylene random complymer concealed pipes (outer diameter of pipe) SDR 7.4 (PN-16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain brass threaded polypropylene random fittings laid in trenches complete all as specified and directed of following sizes:-
(a) 50 mm outer dia
(b) 63 mm outer dia
(c) 90 mm outer dia
Drilling and taping cast iron water mains (in position) for making branch connections complete all as specified and directed of following sizes:-
(a) 15 mm bore
(b) 20 mm bore
S&F in replacement gun metal globe or gate valves, confirming to IS: 778 with iron wheel head, screwed both ends for iron pipe and fixed in existing or new position complete all as specified and directed for following sizes:-
(a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 mm bore
(e) 50 mm bore
S&F in replacement rubber gasket joint for spigot and socketed end CI pipe and fittings complete all as specified and directed for following sizes:-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 to 450 mm bore
M&L for providing joint with rubber or fibre board gasket for flanged pipes and fittings including necessary excavation, returning and refilling complete all as specified and directed for following sizes:-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
(e) 250 mm bore
(f) 300 to 450 mm bore
M&L for cutting/treeming grass, bushes and cleaning inside area of pump house and 2 meter outside fencing with taking proper precautions of electric cables, pipe lines, etc including all T&P as required at site complete all as specifed and directed.
S&F in repairs stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipes complete as specified and directed of following bores:-
(a) 15 mm bore
(b) 20 mm bore
(c) 25 mm bore
(d) 40 mm bore
(e) 50 mm bore
S&F in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm bore (minimum weight 210 gms) complete all as specified and directed.
S&F in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 25 mm bore (minimum weight 455 gms) complete all as specified and directed.
Disconnecting existing water tanks of capacity upto and including 500 litres, setting aside or lowering if required for repairs including making it leak proof using M-Seal or other approved products, replacement of barrel nipple, cleaning, etc and hoisting, reconnecting and refixing in position complete all as specified and directed.
Disconnecting existing water tanks of capacity above 500 litres and upto 1000 ltrs, setting aside or lowering if required for repairs including making it leak proof using M-Seal or other approved products, replacement of barrel nipple, cleaning, etc and hoisting, reconnecting and refixing in position complete all as specified and directed.
M&L for painting to sump/ wall/ pipe etc in main filter pump house with two or more coats of synthetic enamel paint complete all specified and directed.
S&F in repiars new flange type non return valve of size 80 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in repiars new flange type non return valve of size 100 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in repiars new flange type non return valve of size 150 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in repiars new flange type non return valve of size 200 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in repairs new flange foot valve of size 80 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in repairs new flange foot valve of size 100 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in repairs new flange foot valve of size 150 mm including nuts, bolts and all connecting accessories complete all as specified and directed.
S&F in replacement new mechnical joints for DI type, K12 of followng size including nuts, bolts and all connecting accessories complete all specified and directed for following sizes:-
(a) 100 mm bore
(b) 150 mm bore
(c) 200 mm bore
(d) 250 mm bore
(e) 450 mm bore
S&F of PP-R poly propylene random complymer gate valve complete all as specified and directed of following sizes:-
(a) 20 mm bore
(b) 25 mm bore
(c) 32 mm bore
(d) 40 mm bore
(e) 50 mm bore
(f) 63 mm bore
Day to Day Maintenance of GI/CI/DI pipe line various sizes for minor repairing/ rectification and attending the complaint of pipeline leakage/ float valve repairs by highly skilled tradesman as required at site to complete job with stuiplated time without hampering water supply and making supply functional including all necessary T&P complete all as specified and directed for following bores:- Note : - (i) The quoted rate deems to exclude for all excavation and returning filling in. (ii) The tradesman shall report to E/M complaint cell of AGE E/M Bairagarh Bhopal daily at 8.30 am to take complaints from concern JE E/M. The complaint slip duly signed by the users shall be returned back at the complaint cell. (iii) Urgent complaint must be completed either in holiday or sunday. (iv) New GI fittings of suitable size, yarn and safeda/ white lead measured and paid separetally.
(a) 15 mm dia
(b) 20 mm dia
(c) 25 mm dia.
(d) 40 mm dia.
(e) 50mm bore
(f) 80 mm bore
(g) 100 mm bore
(h) 150 mm bore
(j) 200 mm bore
(k) 250 mm bore
(l) 450 mm bore
S&F of 25 mm bore GI socket complete alll as specified and directed.
S&F of 25 mm bore GI elbow complete all as specified and directed.
S&F of 25 mm bore GI union complete all as specified and directed.
S&F of 25 mm bore GI Tee complete all as specified and directed.
S&F of GI reducer 25 x 20 mm bore complete all as specified and directed.
S&F of GI nipple 25 mm bore x 100 mm long complete all as specified and directed.
S&F of 25 mm bore tank nipple complete all as specified and directed.
S&F of 20 mm bore GI Union complete all as specified and directed.
S&F of 20 mm bore GI Tee complete all as specified and directed.
S&F of GI reducer 15 x 20 mm bore complete all as specified and directed.
S&F of GI nipple 20 mm bore x 100 mm long complete all as specified and directed.
S&F of 20 mm bore tank nipple complete all as specified and directed.
S&F of 15 mm bore GI union complete all as specified and directed.
S&F of 15 mm bore GI Tee complete all as specified and directed.
S&F of GI reducer 15 x 25 mm bore complete all as specified and directed.
S&F of GI nipple 15 mm bore x 100 mm long complete all as specified and directed.
S&F of 15 mm bore tank nipple complete all as specified and directed.
S&F of 20 mm bore brass non reurn valve complete all as specified and directed.
S&F of 25 mm bore brass non reurn valve complete all as specified and directed.
S&F of 15 mm bore brass non reurn valve complete all as specified and directed.
Supply of teflon tape packet complete all as specified and directed.
S&F of lead material complete all as specified and directed.
S&F of lead wool complete all as specified and directed.
Complete testing of collected water sample from NABL/approved lab as per IS: 10500 : 2012 at main filter pump house Bairagarh and submission the test report complete all as specified and directed of the following parameters:-
Table 1: Organoleptic and physcial parameters
Table 2: General parameters concerning subtances undesirable in excessive amounts
Table 3: Parameters concerning toxic substance
Table 4: Parameters concerning radioactive substance
Table 5: Pesticide residues limit and test substance
S&F of 80 mm size cast iron double chamber air release valve as per IS: 14845 including nuts, bolts, rubber sheets etc. complete all as specified and directed. sizes:-
S&F of 100 mm size cast iron double chamber air release valve as per IS: 14845 including nuts, bolts, rubber sheets etc. complete all as specified and directed. sizes:-
M&L for complete servicing of chlorine dozing machine through OEM or authorized service technician with and including comprising of dismantling the dozing plant, cleaning, disconnecting electric connection, taking out all defective parts and fixing new parts in replacement complete all as specified and directed. Note: New parts will be measured and paid separately as for supply only.
Supply only the following spare parts of chemical chlorine dozing plant of Make: Satya Sai bac to be incorporated/ required while servicing complete all as specified and directed: -
(a) PVC NRV set with glass ball for suction and delivery adopter.
(b) PVC adopter for suction and delivery without NRV
(c) PVC stainer washer type heavy duty or Y type stainer for suction.
(d) Teflon gland square type 3 mm
(e) Chemical oil seal with cap
Deduct Schedule of credit (calculation will be done off line) Rs. 1,24,495.00
MODI CORPORATION (BID ID -3408969)
PRAGATI ELECTRICALS AND ELECTRONICS (BID ID -3413320)
SULTAN SINGH, CONTRACTOR (BID ID -3412697)
City buildcom builders & devlopers (BID ID -3412747)
AJIT ENTERPRISES (BID ID -3413380)
Neelam Traders (BID ID -3413189)
Raj Contruction (BID ID -3413232)
Neha Enterprises (BID ID -3413182)
M/s logitech solution (BID ID -3413399)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .