Loading…
Loading…
Tender Value
₹46.2 L
EMD Value
₹92,300
Closing Date
1 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
DRAWING
12 conditions · 1 needing a document upload
valid Electrical Contractor license: "The tenderer shall possess a valid Electrical Contractor License, issued by any State Government or Union Territory Administration, authorizing execution of electrical works up to 650V. The contractor shall have in his employment or shall engage a person holding a valid certificate of competency issued by any State Government or Union Territory Administration for supervision of electrical works up to 650V. Offers not accompanied by a valid Electrical Contractor License and requisite Supervisor competency for works up to 650 V shall be summarily rejected". The License should have been issued on a date prior to the date of Tender opening. Clear scanned copy is to be submitted along with the tender. A copy of license should be uploaded through IREPS with their offer, failing which the tender will be rejected.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
91 conditions · 6 needing a document upload
TENDER SHALL BE REJECTED if it is not accompanied by the following:
Cost of tender document & EMD deposited through IREPS e- payment
In case of Partnership firm : The tender form shall be submitted only in the name of partnership firm.
In case tenderer is JV Firm : The tender form shall be submitted 1.1.2 only in the name of the JV and not in the name of any constituent member.
Uploading of Certificate in support of Technical Eligibility (As detailed in Standard Technical Criteria).
Submission of Certificate(s) in support of Financial Eligibility (As detailed in Standard financial criteria).
IN CASE OF ADVERTISED TENDER VALUE IS MORE THAN RS. 20 CRORES: Bid capacity is applicable, the tenderers should submit proforma attached in DOCUMENTS. In case, the tenderer/s failed 1.3.1 to upload BID CAPACITY PROFORMA along with offer, their/his offer shall be considered as incomplete and will be rejected summarily.
In case tenderer is other than sole proprietorship firm, following documents shall be uploaded by the tenderer:
In case the Tenderer is a Partnership Firm: [i] Partnership deed . [ii]Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered). [iv]An undertaking by all partners of the partnership firm that they are not blacklisted or 1.4.1 debarred by Railways or any other Ministry / Department of the Govt. of India / any State Govt. from participation in tenders / contracts as on the date of opening of bids, either in their individual capacity or in any firm in which they were / are partners. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii) a copy of Power of Attorney/Authorisation 1.4.2 issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. (iv) copy of PAN number of the LLP Firm
In case the Tenderer is a Company registered under Companies Act-2013:(i) the copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company; and (ii) A copy of 1.4.3 Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.(iv) copy of PAN number of the Company.
In case the Tenderer is a Registered Society & Registered Trust: (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the 1.4.4 individual to sign the tender documents and create liability against the Society/Trust. (iv) copy of PAN number of the Society/Trust.
Incase JV Firms are allowed to participate: Uploading of MEMORANDUM OF UNDERSTANDING as per the format given in "Documents attached with tender" and also below documents.
In case one or more members is/are Proprietary Firm or HUF, the following documents shall be enclosed:: A copy of notarized affidavit on Stamp Paper declaring that his/her Concern is a 1.5.1 Proprietary Concern and he/she is sole proprietor of the Concern OR he/she is in position of "KARTA" of Hindu Undivided Family (HUF) and he/she has the authority, power and consent given by other partners to act on behalf of HUF.act on behalf of HUF.
In case one or more of the members of the JV is/are partnership firm(s), following documents shall be submitted:]:(a)A copy of the Partnership Deed, (b)A copy of consent of all the partners or individual authorized by partnership firm, to enter into the Joint 1.5.2 Venture Agreement on a stamp paper, (c)A copy of Power of Attorney (duly registered as per prevailing law) in favour of the individual to sign the MOU/JV Agreement on behalf of the partnership firm and create liability against the firm.
In case one or more members of the JV is/are companies, the following documents shall be submitted: (a)A copy of resolutions of the Directors of the Company, permitting the company to enter into a JV agreement, (b) A copy of Memorandum and 1.5.3 Articles of Association of the Company. (c) A copy of Authorization/copy of Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender, sign MOU/JV Agreement on behalf of the company and create liability against the company.
IN CASE THE TENDER VALUE MORE THAN RS. 50 LAKHS; Tenderers shall submit a notarized affidavit on a non-judicial stamp paper stating that all their statements / documents submitted along with bid are true and factual.
Uploading of Declaration regarding Employment of Retired Engineer/Retired Railway Officer as per clause no.17 of Part-I of IRSGCC. [in the format attached in - Documents]
Uploading of NEFT FORM - as per the format attached with the tender document.
The list of personnel / organization on hand and proposed to be engaged for the tendered work.
List of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work.
Uploading of Statement Showing the particulars of Works on Hand & Works Completed as per the format attached to the tender document.
Uploading of certificate by local suppliers in regard to meeting the Minimum Local Content requirement to avail benefits under Public Procurement Policy Order-2017 (A) for procurement order of value less than Rs. 10 crores: self certificate in accordance with Para-9(a) of Public Procurement(Preference to Make in India) Order 2017. (B) For Procurement Order of value more than Rs. 10 crores, the certificate from Statutory auditor/cost auditor/practicing CA as the case may be in accordance with Para-9(b) of Public Procurement (Preference to Make in India) Order 2017.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
IN CASE OF SINGLE PACKET TENDERS; CONSORTIUM AGREEMENTS, JOINT VENTURE FIRMS AND MOUS SHALL NOT BE CONSIDERED
IN CASE OF TWO PACKET TENDERS CONSORTIUM AGREEMENTS AND MOUS SHALL NOT BE CONSIDERED . BUT JOINT VENTURE FIRMS ARE CONSIDERED FOR ELIGIBILITY.
CONDITIONS FOR PARTICIPATION OF PROPRIETARY FIRM / PARTNERSHIP FIRM /PRIVATE LIMITED COMPANY / LIMITED COMPANY/ JV FIRMS:
In case the tenderer is an individual / proprietary concern, the experience and turnover shall be in the name and style of the Individual / Proprietary concern only.
In case the tenderer is a Partnership Firm, the experience and received contractual payments shall be in the name and style of the firm only. The other guidelines at Clause 18 of Part I of 4.1.1 IRSGCC shall be applicable . Note: The partner of a Partnership Firm cannot claim the credentials of Partnership firm to the extent of his share either during the subsistence of the Partnership firm or after its dissolution.
FOLLOWING DOCUMENTS SHALL BE ENCLOSED:
In case the Tenderer is a Partnership Firm: [i] Partnership deed . [ii]Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create 4.2.1 liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered).
In case the Tenderer is a Company registered under Companies Act-2013:(i) the copies of MOA (Memorandum of Association) and AOA (Articles of Association) of the company; and (ii) A copy of Authorization/Power of Attorney issued by the Company 4.2.2 (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.(iii) copy of PAN number of the Company.
In case of JOINT VENTURE (JV) FIRMS: Clause No.17 of Part-I of IRSGCC with upto date correction slip shall be applicable in all aspects for Participation of Joint Venture[JV] firms in works tenders. JV firm should submit Memorandum of 4.2.3 Understanding[MOU] as per the format attached as annexure to the tender in DOCUMENTS. Submission of all other documents by JV firm / Members of JV should also be as per Cl.No.17.14 of Part-I of IRSGCC.
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii) a copy of Power of Attorney/Authorisation 4.2.4 issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. (iv) copy of PAN number of the LLP Firm
In case the Tenderer is a Registered Society & Registered Trust: (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the 4.2.5 individual to sign the tender documents and create liability against the Society/Trust. (iv) copy of PAN number of the Society/Trust.
Uploading of other relevant documents connected to the tender; such as Declaration regarding employment of Retired Engineer/ Retired Railway officer, NEFT Form, List of Personnel/Organization, List of Plant/machinery, Particulars of works on hand and completed (As per the formats attached in the list of Documents)etc.
Hyderabad Division: Improvements to old structures and offices in Mazdoor Union Office Premises under Jurisdiction of SSE/W/GOC - Electrical Arrangements
32-OSW-26-27-SrDEE-M-HYB~SCR
32-OSW-26-27-SrDEE-M-HYB
Open
Works - General
12 Months
Hyderabad, Telangana
₹0
₹92,300
3 Sept 2026
3 Sept 2026
17 Sept 2026
131 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 46,16,452 | ||
| — | 1800.00 | — | — | ||
| Supply & laying of PVC conduit pipe of 25 mm dia 2 mm thick in concealed/surface as per the directions of Engineer at site | — | — | — | 55,800 | |
| — | 600.00 | — | — | ||
| Supply & laying of PVC conduit pipe of 32 mm dia 2 mm thick in concealed/surface as per the directions of Engineer at site | — | — | — | 33,000 | |
| — | 800.00 | — | — | ||
| Supply & fixing of PVC conduit moulded bend pipe 32/25 mm dia 2 mm thick in concealed | — | — | — | 22,400 | |
| — | 400.00 | — | — | ||
| Supply & fixing of PVC Junction box of suitable way for 32/25 mm dia 2 mm thick PVC conduit pipe in concealed | — | — | — | 10,000 | |
| — | 100.00 | — | — | ||
| Supply, laying and fixing of water proof PVC casing & caping of size 20/25 mm of 2 mtrs length each including all connected accessories etc. | — | — | — | 6,500 | |
| — | 100.00 | — | — | ||
| Supply, laying and fixing of water proof PVC casing & caping of size 50mm of 2 mtrs length each including all connected accessories etc. | — | — | — | 12,000 | |
| — | 300.00 | — | — | ||
| Supply and laying of flexible 25mm PVC pipe | — | — | — | 5,400 | |
| — | 100.00 | — | — | ||
| Cutting and chipping the wall for laying the PVC conduit pipe and plastering after laying the PVC conduit pipe with cement and sand mortar mixed with 1:8 ratio, but without laying PVC conduit pipe. | — | — | — | 3,400 | |
| — | 5760.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core FRLS multi strand 1.5 sq. mm Cu. Conductor | — | — | — | 1,49,760 | |
| — | 3780.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core FRLS multi strand 2.5 sq. mm Cu. Conductor | — | — | — | 1,58,760 | |
| — | 1800.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core FRLS multi strand 4 sq. mm Cu. Conductor | — | — | — | 1,17,000 | |
| — | 900.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core FRLS multi strand 6 sq. mm Cu. Conductor | — | — | — | 87,300 | |
| — | 180.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core FRLS multi strand 10 sq. mm Cu. Conductor | — | — | — | 32,220 | |
| — | 180.00 | — | — | ||
| Supply, laying, connecting and commissioning of 3 core 1.5 mm sq.mm multi stranded FRLS cu. Conductor as per the directions of Engineer at site | — | — | — | 16,380 | |
| — | 180.00 | — | — | ||
| Supply, laying, connecting and commissioning of 3 core 2.5 mm sq.mm multi stranded FRLS cu. Conductor as per the directions of Engineer at site | — | — | — | 25,920 | |
| — | 200.00 | — | — | ||
| Supply and erection of ceiling rose. | — | — | — | 8,000 | |
| — | 500.00 | — | — | ||
| Supply & erection of 6/10A 1-way switch | — | — | — | 32,500 | |
| — | 100.00 | — | — | ||
| Supply & erection of 16/20A one way switch | — | — | — | 8,800 | |
| — | 80.00 | — | — | ||
| Supply & erection of 6/10A socket with safety shutter | — | — | — | 6,800 | |
| — | 80.00 | — | — | ||
| Supply & fixing of 16/20/10A socket heavy duty with safety shutter | — | — | — | 11,280 | |
| — | 30.00 | — | — | ||
| Supply & fixing of 20/25A capacity MCB DP similar to GM make as per the directions of engineer at site | — | — | — | 13,050 | |
| — | 4.00 | — | — | ||
| Supply & erection of 3 way module size GI sheet metal/PVC box in concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 244 | |
| — | 4.00 | — | — | ||
| Supply & erection of 3 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 308 | |
| — | 10.00 | — | — | ||
| Supply & erection of 6 way module size GI sheet metal/PVC box in concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 960 | |
| — | 10.00 | — | — | ||
| Supply & erection of 6 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 1,220 | |
| — | 6.00 | — | — | ||
| Supply & erection of 8 way module size GI sheet metal/PVC box in concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 732 | |
| — | 6.00 | — | — | ||
| Supply & erection of 8 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 918 | |
| — | 10.00 | — | — | ||
| Supply & erection of 12 way module size GI sheet metal/PVC box concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 1,580 | |
| — | 10.00 | — | — | ||
| Supply & erection of 12 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 1,890 | |
| — | 10.00 | — | — | ||
| Supply & erection of 18 way module size GI sheet metal/PVC box concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 1,940 | |
| — | 10.00 | — | — | ||
| Supply & erection of 18 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 2,420 | |
| — | 4.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 60W LED street light complete with necessary clamps and hardware etc. as per Railway specification | — | — | — | 11,240 | |
| — | 20.00 | — | — | ||
| Supply and fixing of 100W LED flood lights (red/ green/ warm white/ cool white/ blue, based on site requirement) with secondary optics suitable to operate on 230V, 50Hz AC supply as per the specification mentioned in scope of work | — | — | — | 1,10,000 | |
| — | 40.00 | — | — | ||
| Supply & fixing of 15W LED recess mounting down lighting round, greater than 180mm dia suitable to operate on 230v, 50Hz AC supply as per HQ specification and as per the directions of engineer at site. | — | — | — | 25,200 | |
| — | 1.00 | — | — | ||
| Supply & fixing of chandelier light including all accessories as per the directions of engineer at site | — | — | — | 34,656 | |
| — | 40.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 35W LED panel light fitting 2'x2' square type white with other connected accessories etc. as per the directions of engineer at site. | — | — | — | 1,09,200 | |
| — | 16.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 20 Watts 1200mm LED tube light fitting with aluminium body (warm white/ cool white) with lamp including wiring connections etc. as per enclosed specification as per the directions of Engineer at site | — | — | — | 9,008 | |
| — | 80.00 | — | — | ||
| Supply & fixing of cable termination lug & Glands as per the site requirement | — | — | — | 8,000 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of 300mm sweep, 1400 rpm (approx) propeller type exhaust fan complete as per IS, IE rule & site requirement. | — | — | — | 18,440 | |
| — | 8.00 | — | — | ||
| Supply & fixing of 1200 mm sweep energy saving BLDC ceiling fan with copper winding and remote control, 300mm length of down rod (without shackle), input power not more than 28W, minimum 1.1mm aluminium blade material, double ball bearing, 2 canopy, to be operated in AC single phase supply as per spec. | — | — | — | 22,976 | |
| — | 8.00 | — | — | ||
| Supply and fixing of fan hooks (D Hook with double fasteners 10 mm for hanging ceiling fans) as per the direction of site Engineer | — | — | — | 2,312 | |
| — | 8.00 | — | — | ||
| Supply and fixing of 2/3/4/6 feet down rod as per the direction of site Engineer | — | — | — | 2,312 | |
| — | 50.00 | — | — | ||
| Supply, installation and commissioning of LED colour Rope light multi colour (warm white, white, green, saffron, pink, blue) as per the direction of site Engineer suitable to operate on 220V to 250V single phase AC supply as per directions of engineer at site | — | — | — | 7,450 | |
| — | 5.00 | — | — | ||
| Supply, installation and commissioning of Connectors for Rope light as per directions of engineer at site | — | — | — | 1,350 | |
| — | 15.00 | — | — | ||
| Supply, installation, testing, gas charging & commissioning of 2TR capacity BEE star Inverter cassette AC unit, copper coil with all connected accessories. | — | — | — | 17,08,800 | |
| — | 15.00 | — | — | ||
| Supply, fabrication and fixing of suitable size out door wall mounted chair type MS base frame stand for outdoor unit 2/ 3.0TR cassette unit including all connected accessories etc. | — | — | — | 35,400 | |
| — | 200.00 | — | — | ||
| Supply, installation of hard/soft copper refrigerant piping complete with insulation foaming with wrapping, fittings, elbows, bends, supporting arrangements on wall for 2/3TR Cassette Split AC (if required as per site condition) | — | — | — | 2,24,200 | |
| — | 200.00 | — | — | ||
| Supply and fixing of drain pipe CPVC of 25mm dia including accessories, bend, elbows, tees, flanges, tappings, wall sleeves, hangers supports anchors etc. | — | — | — | 38,600 | |
| — | 300.00 | — | — | ||
| Supply and fixing of 4 corex4Sq.mm flexible FRLS copper cable (communication cabling) for Split/Cassette AC | — | — | — | 1,09,500 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of (DP MCB - Incoming & SP/MCB - Outgoing) wall mounted of one row 12 module circuit breaker box made out of thermoplastic, (with metric knockouts for cable entry) with N terminal, size (202 x 238 x 111)mm complete. The LT distribution board shall be comprising with the following MCBs fixed in it conforming to IS:8828:1996, ISS & IE rules and site requirement.DP MCB 40-63 Amps. 'C' series = 01 No. (Incoming) SP MCB 6-32 Amps. 'B' series = 07 Nos. (Outgoing) | — | — | — | 30,092 | |
| — | 2.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 6 way TPN DB in surface/concealed & comprising of 2 x 63A 4P 300mA RCBO, 18 x 6/10/16/20/32A MCB SP with Double door, flush mounting, similar to Legrand make as per the directions of engineer at site. | — | — | — | 27,946 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of 24 module DB out door type of make Havells, Siemens, L&T, Schneider, Legrand or equivalent with following items of matching make to be fixed in distribution board, confirming to IS:8828:1996 or latest, IE rules and site requirement.4P MCB 63 Amps. 10 KA 'C' series = 01 No. (Incoming) DP MCB 6-32 Amps. 10 KA 'C' series = 6 Nos. (Outgoing)SP MCB 6-32 Amps. 10 KA 'C' series = 6 Nos. (Outgoing) | — | — | — | 24,904 | |
| — | 800.00 | — | — | ||
| Supply of 4core 120 mm² LT XLPE aluminium UG Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest. | — | — | — | 7,96,800 | |
| — | 800.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4 core 120 sq.mm multi strand LT XLPE cable as per directions of the engineer at site. | — | — | — | 26,400 | |
| — | 800.00 | — | — | ||
| Supply and fixing of G.I. wire earth continuity of 8 SWG G.I. wire | — | — | — | 7,200 | |
| — | 600.00 | — | — | ||
| Excavation of cable trench 30 cm widex90cm deep in all types of soils for LTUG cable as per the direction of engineer at site | — | — | — | 78,000 | |
| — | 150.00 | — | — | ||
| Cutting of asphalted road/ concrete/ cement/ under the track etc., and excavation of cable trench 30 cm widex90cm deep road etc., for laying of LTUG cable. After laying of cable the trench should be brought to its original position by providing tar/ concrete/ cement as per the site conditions and as per directions of Rly. Engineer. | — | — | — | 32,400 | |
| — | 600.00 | — | — | ||
| Supply & erection of HDPE pipe of 50 mm dia, PN-6, PE-100 of material grade as per IS 4984-2016 or latest, as per the directions of Engineer at site | — | — | — | 1,08,000 | |
| — | 4.00 | — | — | ||
| Supply of earth pit materials and construction of earth pit as per IS 3043:1987 specification. This item also includes of supply and erection of CI pipe of size of 100mm inner diameter, 13mm thickness and 3000mm length. This work also includes of fabrication and fixing of GI strips for earthing connection. Excavated earth pit should be filled by mixture of coke/charcoal, salt and sand up to top. Provision of brick masonry chamber of size 650mmx650mm and depth upto 1000mm including light type CI cover frame and applying 12mm thick cement plaster in 1:3 inside and to all the exposed faces up to 300mm below. Foundation level, curing etc., All required materials for this job such as CI pipe cover with frame, salt, cement sand, charcoal gravel, bricks, etc. required bolts, nuts and double washers, number plates or painted plates. Tentative quantity of salt and charcoal shall be of 2.5CMt. The painted with 2 coats of bitumen paint as per the directions of Rly engineer at site. Note: The work should be strictly done as per IS 3043:1987 specification or latest. | — | — | — | 34,800 | |
| — | 20.00 | — | — | ||
| Supply, laying, connecting & commissioning of 40 mm x 5 mm/ 25 mm x 5 mm thick GI Strip for earth pit as per the directions of engineer at site | — | — | — | 1,400 | |
| — | 10.00 | — | — | ||
| Supply and fixing of 20A SP MCB 'C' curve 10KA | — | — | — | 1,390 | |
| — | 10.00 | — | — | ||
| Supply, fixing, connecting and commissioning of Master control 16A DP MCB as per the direction of the Engineer at site | — | — | — | 4,260 | |
| — | 1.00 | — | — | ||
| Supply, erection, commissioning of 63A/100A 4 Pole RCCB 6 KA with 100mA sensitivity as per the direction of the engineer at site. | — | — | — | 3,744 | |
| — | 1.00 | — | — | ||
| Supply and fixing of 40 amp 4pole 32mA RCCB as per the direction of the engineer at site. | — | — | — | 2,790 | |
| — | 1.00 | — | — | ||
| Design, supply, installation, testing and commissioning of cubicle type 14SWG LT panel (Indoor type) with 250 amps sectionalized electrolytic copper bus bar (phase RYBN uniform sizes). LT switchgear confirming to IS-8623 or latest. Advanced Multi function meters with CTs of suitable capacity with R.S.485 port for incoming supply with CTs of suitable and RYB LED indication lamps with all other connected accessories etc., as directed by Engineer at site. (1) 2 x 125 A 4pole 35/36KA Microprocessor based MCCB (I/C), 1x125A change over switch. Out goings: 4x63A FP 'C' curve 10KA, 6x40 Amps FP 'C' curve 10KA MCB, 2x32A DP 'C' curve 10KA MCB, 6x16A SP 'C' curve 10KA MCB. Note: MCCBs: ICs=100% ICu | — | — | — | 1,29,200 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
NEFTForm.pdf
ATTACHMENT
ExperianceCertificate.pdf
ATTACHMENT
New GCC April 2022
ATTACHMENT
I_CT_GCC-
ATTACHMENT
3toGCCApril.2022RBCE_CE-I-
ATTACHMENT
GCC-2022-
ATTACHMENT
GCCACS11dt.13.03.2026.pdf
ATTACHMENT
ApprovedTB32-26-27.pdf
ATTACHMENT
GCC_April-2022_2022_New.pdf
ATTACHMENT
CorrectionSlip2022_CE-I_CT_GCC-2022Policy14.07.2022_1.pdf
ATTACHMENT
ACS-3toGCCApril.2022RBCE_CE-I-CT2023_04_26.pdf
ATTACHMENT
ACS-2toGCC-2022-CE-1-CT-GCC-2022-POLICY_13.12.2022.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .