Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Being L1 bidder. | |
| 2 | L2₹41.4 L+₹1.1 L (2.67%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹47.7 L+₹7.4 L (18.4%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹48.3 L+₹8.0 L (19.8%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹49.9 L+₹9.6 L (23.8%)Rejected-AOC | L5 | Rejected-AOC Not the L1 bidder. |
Tender Value
₹62 L
EMD Value
₹1.2 L
Closing Date
4 Sept 2024, 6:00 pmClosed
Commander Works Engineer Hisar
Headquarters Commander Works Engineer Military Engineer Services Hisar, Military Station Hisar Hisar (Haryana)-125006
REPAIR AND REPLACEMENT OF STREET LIGHT, GARDEN LIGHTS, CABLES AND CONNECTED ITEMS UNDER GE HISAR
2024_MES_662231_1
CWE/HSR/23 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hisar
As per Notice Inviting Tender (NIT)
7 documents required · 7 mandatory
₹1,000
Yes
GE Hisar
₹1.2 L
Yes
18 Oct 2024
26 Jun 2024
6 Sept 2024
26 Jun 2024
4 Sept 2024
17 Jul 2024
26 Jun 2024 - 24 Jul 2024
Amount
S & F including testing LED high bay 100 watt luminaire with aluminium die cast housing with mechanical mechanism for mounting, with driver complete suitable for fixation on wall/roof/railings with robust body, corrosion resistant, superior finish. The system wattage of fitting should not be more than 100 watt ± 10%, having surge protection of minimum 4kV internal, protection grade IP 65, power factor more than 0.95, corelated colour temperature should 5700⁰-6500⁰ Kelvin, total hormonic distortion (THD) should not be more than 10%, lumen efficacy should not be less than 130 lumens per watt, total input voltage range 140-270V AC, colour rendering Index should not be less than 70 including fixing at any height on high mast and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. Note: - (i) Cost of mechanical mountings and holders for lights, nut & bolts are inclusive in this item.
S & F in repairs flood lights nominal 120 watt luminaire with aluminium pressure die cast housing with pure polyester powder coated, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, built-in electronic LED driver (APFC) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, beam angle of 120⁰ clear, CW available CCT of 5700⁰K, power factor of minimum 0.95, total hormonic distortion (THD) less than 10%, colour rendering index greater than 70, life span of minimum 50000 working hours including fixing at any height on high mast and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S & F in repairs flood lights nominal 100 watt luminaire with aluminium pressure die cast housing with pure polyester powder coated, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, built-in electronic LED driver (APFC) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, beam angle of 120⁰ clear, CW available CCT of 5700⁰K, power factor of minimum 0.95, total hormonic distortion (THD) less than 10%, colour rendering index greater than 70, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S & F in repairs flood lights nominal 70 watt luminaire with aluminium pressure die cast housing with pure polyester powder coated, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, built-in electronic LED driver (APFC) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, beam angle of 120⁰ clear, CW available CCT of 5700⁰K, power factor of minimum 0.95, total hormonic distortion (THD) less than 10%, colour rendering index greater than 70, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S & F in repairs LED post top lights nominal power 45 Watt, pure polyester UV resistant powder coated die cast aluminium housing with PMMA opal diffuser for uniform illumination, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 4500, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 65, CW available CCT of 5700⁰K, power factor of minimum 0.95, colour rendering index greater than 70, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S & F in repairs LED post top lights nominal power 20 Watt, pure polyester UV resistant powder coated die cast aluminium housing with PMMA opal diffuser for uniform illumination, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2000, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 65, CW available CCT of 5700⁰K, power factor of minimum 0.95, colour rendering index greater than 70, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S & F in repairs LED bollard lights nominal power 10 watt, pressure die-cast aluminium alloy housing with polyester powder coated, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 800, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 2 kVs, protection grade IP 65, CRI greater than 70, CW available CCT of 5700⁰K, power factor of minimum 0.95, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
Disconnecting all existing connections with LT panel board and taking down and shifting LT panel board to another location with help of Hydra (Recovery)/JCB/ Crane etc. and refixing LT panel board including necessary wiring for electrical connections and including excavation, earthworks, PCC foundation in M15 (Nominal Mix) concrete complete all as specified and as directed.
S & F in repairs constant current LED drivers for wattage capacity of 35 W to 100 W complete all as specified and as directed.
S & F in repairs surge protection device for 4 kV for LED light fittings complete all as specified and as directed.
M & L for bracket made out of GI pipe 32 mm dia medium grade, 1.2 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick mild steel nuts, bolts including taking down old unserviceable complete all as specified and as directed.
S & F medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983, nominal size 20 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed.
S & F in repairs three core flexible conductor FR-LSH cables for outdoor use, PVC insulation of type C and having PVC sheath of type ST2, 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor for fittings complete all as specified and as directed.
S & F in repairs two core flexible conductor FR-LSH cables for outdoor use, PVC insulation of type C and having PVC sheath of type ST2, 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor for fittings complete all as specified and as directed.
M & L for trimming of branches of trees touching HT/LT Electric over head line and making clear about 3 m in radius and carrying and disposal where directed not exceeding 50 m complete all as specified and as directed. Note :- Vehicle and othe T&P shall be arranged by the contractor at own cost.
M & L for preparing and painting on steel tubular swaged pole 410 SP-31 (9.00 metre long) including cross arms, GI brackets with two coats of aluminium paint over a coat of aluminium red oxide primer on exposed portion and including making strips of width 30 cm upto 1.5 m from the ground level in black and white shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M & L numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Disconnecting all existing connections and taking down old defective underground LT cable of size 6 sqmm to 25 sqmm upto 4 core in loop of maximum length upto 3 m including excavations, earthworks, taking out bricks, sand etc and supplying and layning new LT cable of size 6 sqmm to 25 sqmm upto any core, filling with new river sand and laying of old bricks including making connection with proper new thimbles in junction box, feeder pillar box, MCCBs, MCBs etc. complete all as specified and as directed.
S & F in repairs junction box suitable for street light of size not less than 350 mm X 250 mm X 150 mm, made out of polycarbonate, front openable with locking arrangement, 3 phase, 50 Hz, AC supply, provided with 4 Nos of aluminium busbar of current rating 200 Amps including neutral terminal and 1 No MCB 6 Amp Single Pole, provision for 2 Nos of cable entries of size upto 16 sqmm 4 core, to be fixed on pole with proper size mild steel clamps, nuts and bolts complete all as specified and as directed.
M & L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Restringing only ACSR (aluminium conductor galvanized steel-reinforced) of any size and type in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.
Disconnecting, taking out old unserviceable under ground cable of rated voltage 1100 V, nominal cross sectional area of main conductor upto any size and upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for taking credit or for relaying complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 6 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supplying and fixing PVC insulated cable for working voltages of 1100 V, PVC sheathed, unarmoured, 2 core, flat or circular nominal cross sectional area of main conductor 16 sqmm, solid aluminium conductor, ISI marked as per IS 1554(Part-I): 1988 including cable glands, lugs etc. to suit the cable in service connections suspended by insulating hangers not more than 1 metre apart including 4 sqmm suspension wire complete all as specified and as directed.
Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 50 mm, minimum inside dia 37 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
Laying only bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and as directed.
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI pipe of 50 mm and 40 mm nominal bore complete all as specified and as directed.
Supplying & laying including taking down in trenches, in road cutting and along pole 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
S & F isolator TPN, 63 A, 415 V complete all as specified and as directed.
Supply & fixing in repairs 3 Phase, 5 kW automatic street light control switch using infrared sensor based twilight/ nature switch for automatic switching of streetlights, consisting of weatherproof powder coated metal box of suitable size, 1 No of twilight/ nature switch dusk to dawn, 25 Amps 3 Pole contractor- 1 No, 20 Amps MCB- 6 Nos (3 Nos input and 3 Nos output) including wiring with10 sqmm copper wiring, IP54 protection grade complete all as specified and as directed.
Supplying, installing, testing and commissioning in repairs factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 150 Amps rated aluminium busbar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. And shall be comprising the followings: - (A) 150 Amps rated aluminium busbar fully insulated with class F materials and nuts, bolts, washers for connection: - 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size © MCB 63A TPN as incoming - 01 No (D) MCB SPN 32 upto 05 Nos € The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.)
Dismantling concrete poles/ struts, any size, setting aside for reuse within 50 metres
M & L for steel tubular swaged pole 410 SP-31 (9.0 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
Dismantling insulators any type, any size complete all as specified and as directed.
S & F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50 mm height, 65 mm dia for 550 volts grade complete all as specified and as directed.
S & F shackle type porcelain vitreous white brown or green insulator for working pressure 1100 volts of 75 mm dia and 90 mm height including galvanised steel straps of 31 mm X 3 mm size insulator bolt, washer & nuts complete all as specified and as directed.
Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in flooring finished even and smooth without using extra cement complete all as specified and as directed.
S & F composite spacer for maintaining the specified spacing between two Nos of conductors for 415 V/ 240 V overhead line, made of poly propylene in a single mould except clamping pieces, 25 mm width X 12 mm depth, projected 30 mm beyond the external conductor on both sides complete all as specified and as directed.
S & F composite spacer for maintaining the specified spacing between five Nos of conductors for 415 V/ 240 V overhead line, made of poly propylene in a single mould except clamping pieces, 25 mm width X 12 mm depth, projected 30 mm beyond the external conductor on both sides complete all as specified and as directed.
Supply, fixing and stringing ACSR (aluminium conductor galvanized steel-reinforced) of any size and type in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.
S & F in repairs solar streetlight, LED type, 25 watt capacity with pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, lumen output of minimum 3750, lumen efficacy of minimum 150 lumens per watt, Total Harmonic Distortion (THD) less than 10%, corelated colour temperature should 5500⁰-6500⁰ Kelvin, protection grade IP 66, CRI greater than 70, in built DC-DC type driver including lithium based battery of capacity 11.1 V/ 39 AH or 12.8 V/ 34.5 AH, light backup time 24 hours, Solar PV Module 60 Wp Mono Crystalline with inbuilt Battery management system (BMS), microcontroller based charge controller cum driver, automatic dimming function with PRI motion sensor, dusk to down operation, lux output 25 (from 9 metre height), working temperature (-)10⁰ to (+) 55⁰c including battery over charge protection, battery deep discharge protection, battery reverse polarity protection, no load/open load protection, load short circuit protection, solar panel & battery connection interchange protection including GI pipe bracket of suitable dia medium grade pipe bent to shape of approximately 1.5 metre length 1.5 including 2 Nos mild steel clamp of flat iron of suitable size with nut, bolt washer including 4 metre long octagonal GI pole, top dia 70 mm and bottom dia 130 mm, thickness of sheet 3mm, base plate size 200 mm X 200 mm x 12 mm, foundation bolts 4 Nos, 16mm dia, 450mm long including necessary civil works as earthworks, footing with PCC M15 (Nominal Mix concrete) using 20 mm crushed stone coarse aggregate, reinforcement etc. complete all as specified and as directed. Note: The product shall be made in India with CE & ROHS certification.
M/S KAVITA CONSTRUCTION (BID ID -3069687)
malik constructions (BID ID -3072675)
NAVIN KUMAR (BID ID -3072177)
M/S D.N Choudhary (BID ID -3073305)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .