| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹36.5 L+₹3.0 L (9.06%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹44.7 L+₹11.2 L (33.4%)Rejected-Finance FLAT NO 105 CVS CAUVERY MANSION PLOT NO 31 MODEL COLONY NEAR ESI HOSPITAL SR NAGAR HYDERABAD 500 038 | HYDERABAD | HYDERABAD | TELANGANA | 500038 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹48.6 L+₹15.1 L (45.0%)Rejected-Finance 58 CHANDRALOK BUILDING MAYO HOSPITAL ROAD NAGPUR 440 018 | NAGPUR | MAHARASHTRA | 440018 | L4 | Rejected-Finance Not Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
15 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIR/MAINTENANCE OF LT OH LINES, UG CABLES AND LT SWITCH GEARS INSTALLED AT DRDL/ASL AREA UNDER GE (I) RND KANCHANBAGH, HYDERABAD
2022_MES_547881_2
GE(I)/KBAGH/TOKEN/43 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹98,000
Yes
9 Nov 2022
26 Sept 2022
17 Oct 2022
26 Sept 2022
15 Oct 2022
3 Oct 2022
26 Sept 2022 - 30 Sept 2022
Amount
Supply , install test & commission of LT Panel in door, Cubicle type, free standing floor/plinth mounting confirming IEC 61439 factory fabricated out of CRCA Sheet of 2.0 mm thick dust, vermin & weather proof, IP-52 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing color coded PVC sleeved aluminium bus bar of capacity 600 Amps rating for 415 V 50 Hz 3 Phase 4 wire system, cotated with RAL7032 after 7 tank process with thickness of min 80 mircons including internal wiring using suitable size not less than 1.5 sqmm FRLS copper conductor cable along with ferouts. The panel should be mounted on 'C' channel base of required size duly coated with anti corrosive paint. the circuit distribution lines to be marked over the panel using poly venyl reflective stickering (Where necessary) including taking out old panel complete with following:-.
(a) MCCB 400 Amps, 4 pole, 36 KA Icu=100% Ics, thermal magnetic adjustable over load & short circuit ratings with rotary handles, spreader links - 01 No. (I/C) (b) MCCB 200 Amps, 4 pole, 36 KAIcu=100% Ics, thermal magnetic adjustable over load & short circuit ratings with rotary handles, spreader links - 01 No. (out going) (c) MCCB 100 Amps, 4 pole, 25 KA Thermal magnetic, adjustable over load & short circuit currents, Icu=100% Ics - 02 Nos. (out going) (d) MCCB 63 Amps, 4 pole, 16 KA 'C' curve Icu=100% Ics - 04 Nos. (out going) (e) Spare space for MCCB 250 Amps -01 No.
Ditto all as per Item No: 1 above but indoor type made out of 2.0 mm thick CRCA sheet with aluminium bus bar of capacity 600 Amps, including fixing of the following items :-
(a) MCCB 400 Amps, 4 pole, 36 KA Icu=100% Ics, thermal magnetic adjustable over load & short circuit ratings with rotary handles, spreader links - 01 No. (I/C) (b) MCCB 100 Amps, 4 pole, 25 KA Thermal magnetic, adjustable over load & short circuit currents, Icu=100% Ics - 01 No. (out going) (d) MCCB 63 Amps, 4 pole, 16 KA 'C' curve Icu=100% Ics - 05 Nos. (out going) (d) MCB 63 Amps, 4 pole, 10 KA Thermal magnetic, adjustable over load & short circuit currents, Icu=100% Ics - 04 Nos. (out going) (e) MCB 32 Amps, 4 pole, 10 KA 'C' curve - 02 Nos. (out going) (f) Spare space for MCCB 250 Amps -01 No.
Supply , install test & commission of LT Panel in door type, Cubicle type, tree standing floor/plint mounting confirming IEC 61439-2 factory fabricated out of MS CRCA Sheet of 2.0 mm thick dust, vermin proof, weather proof, IP-54 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing aluminium bus bar of capacity 1600 Amps rating for 415 V 50 Hz 3 Phase, 4 wire system cotated with RAL7032 after 7 tank process with thickness of min 80 mircons including internal wiring using suitable size not less than 1.5 sqmm FRLS copper conductor cable along with ferouts. The panel should be mounted on 'C' channel base of required size duly coated with anti corrosive paint. the circuit distribution lines to be marked over the panel using poly venyl reflective stickering (Where necessary) including taking out old panel complete with following:-.
(a) ACB 630 Amps 4 pole 50 KA with microprocessor release, Ics= Icu=Icw = 50 KA manual draw out type with adjustable overload setting (minimum 70% to 100%) -01. (b) MCCB 320 Amps, 4 pole, 36 KA microprocessor release type with rotary handles, spreader links - 01 No. (out going) (c) MCCB 250 Amps, 4 pole, 36 KA Icu=100% Ics, thermal magnetic adjustable over load & short circuit ratings with rotary handles, spreader links - 05 No. (out going) (d) Spare space for MCCB -01 No.
Supply, Laying, Test & Commissioning LT UG cable of size 300 sqmm; 3.5 core XLPE insulated, armoured, multistranded, aluminium conductor electric cable of 1100 volts grade laid in ground, through trench/pipes including connecting with aluminium lugs etc and including removing old unserviceable cable all as specified and directed.
All as per Item No 4 here-in-before above but of size 3.5 core 240 sqmm all as specified
All as per Item No 4 here-in-before above but of size 3.5 core 185 sqmm all as specified
All as per Item No 4 here-in-before above but of size 3.5 core 95 sqmm all as specified
All as per Item No 4 here-in-before above but of size 3.5 core 70 sqmm all as specified
All as per Item No 4 here-in-before above but of size 3.5 core 50 sqmm all as specified
Excavation in trenches not exc.1.5 Mtr in width and not exceeding 1.5 Mtr in depth for laying of cables and getting out in soft/loose soil etc complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick using soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point all as specified.
Supply and laying in repairs corrugated HDPE pipe of 40mm dia for cable protection confirming IS-14930 1 & 2 , in trenches or fixing to the pole with necessary accessories complete all as directed. Make:Astral/Sudhakar or equalent ISI certified manufacturer.
Supply and laying in repairs corrugated HDPE pipe of 63 mm dia for cable protection confirming IS-14930 1 & 2 , in trenches or fixing to the pole with necessary accessories complete all as directed. Make:Astral/Sudhakar or equalent ISI certified manufacturer.
Material and Labour for cutting existing BT road/PCC of size 45cm x 60cm for taking out/laying of underground cable and including necessary earth work and refilling the same in layers well ramming including watering as required and matching with the existing surface with 200mm thick PCC 1:2:4 type B1 and curing the same with wet gunny bags and removing debris to a distance not less than 50m complete all as specified and directed.
Supply and Fix in repairs GI tubing 100 mm dia light grade for protection of earth conductor and all as specified and directed.
Supply and Fix in repairs GI tubing 150 mm dia light grade for protection of earth conductor and all as specified and directed.
Taking out the LT ACB of 400 to 800Amps capacity of any make and model from the existing position, carrying out servicing, overhauling of the same, cleaning the unit thoroughly with carbon tetrachloride, applying lubricant oil and grease for the moving contacts, checking of the entire components for proper function on O/L and S/C, checking the trip device and circuit wiring complete reconnecting back and testing complete all as specified and directed.
All as per item No. 18 above but 1000 to 1600 Amps capacity of any make and model.
All as per item No. 18 above but 2000 to 4000 Amps capacity of any make and model. Note for item No 18 to 20 spares shall be measured and paid separately
M&L for LT Panel board , fabricating, brazing/welding , hinges, locking arrangenent supports, of any size as directed including nuts, bolts, washers welding, bending, cold or hot, drilling holes for bolts in any shape or size as directed.
Supplying and Fixing in repairs ACB 630Amps, 415V, 50KA, drawout type with Microprocessor release IPR-1 (4Pole) inbuilt O/L, S/C & EF protection, fixed in existing panel boards including cable connections, aluminium lugs, glands & terminal adaptors as required and testing complete all as specified and directed. Make : Havells/Legrand/Siemens
Supplying and Fixing in repairs ACB 1250Amps, 415V, 50KA, drawout type with Microprocessor release IPR-1 (4Pole) inbuilt O/L, S/C & EF protection, fixed in existing panel boards including cable connections, aluminium lugs, glands & terminal adaptors as required and testing complete all as specified and directed.
Supply and Fix male and female contacts copper/brass as per existing type for RYB phases suitable for 11 KV SF6 circuit breaker complete set and testing including removing worn out contacts from the breaker complete all as specified and directed.
Supply and Fix indicator lamps LED type (R/Y/B) 110 Volts for HT/LT panels/breakers including removing of the unserviceable complete all as specified and directed. Make :- L&T/Alstom/Siemens
Material and labour for XLPE cable end joint, out door heat shrinkable type of 11KV (earthed) grade cable , 120 to 185 sqmm; 3 core complete with jointing material and accessories including removing the unserviceable joint all as specified.
All as per item No: 28 above but indoor type
All as per item No: 28 above but of size 50 to 95 sqmm indoor type
All as per item No: 28 above but of size 50 to 95 sqmm outdoor type Make for item No. 28 to 31 : Raychem/3M/Densons
S&F in repairs Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm.
All as per item No. 32 above but of size 120 sqmm to 185 sqmm
Material and labour for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtrs below ground level with the top edge of earth plate at a depth of not less than 1.5 mtrs below normal ground level, connected to and including galvanised iron earth strip of size 32x6 mm with GI medium grade protection pipe of 40 mm dia for earth electrode upto test point or upto 7.5 mtr whichever is less, by means bolts, nuts, check nuts and washers of galvanised iron including necessary excavation earth work in any type of soil, PCC pit (1:3:6) type C1 and RCC cover (1:2:4) type B1 of 40 mm, watering pipe 20 mm dia GI pipe, wire mesh, funnel, lugs, charcoal, salt etc complete all as per electrical plate No. 3 or SSR Part-I including taking out old earthing complete all as specified and directed. Note : GI strip and GI pipe 40 mm dia beyond 7.5 metres per earth will be measured and paid separately.
Supply and Fix in repairs galvanised iron strip of size 32x6 mm burried in ground/on wall as earth continuity conductor and all as specified and directed.
Supply and Fix in repairs GI tubing 40 mm dia light grade for protection of earth conductor and all as specified and directed. Make : Jindal/Prakash/Oswal
Supply & Fix in repairs cable lugs of size 300 to 400 sqmm complete all as specified and directed.
Supply & Fix in repairs cable lugs of size 185 to 240 sqmm complete all as specified and directed.
Supply & Fix in repairs cable lugs of size 120 to 150 sqmm complete all as specified and directed.
Supply & Fix in repairs cable lugs of size 70 to 90 sqmm complete all as specified and directed.
Supply & Fix in repairs cable lugs of size 35 to 50 sqmm complete all as specified and directed.
Supply & Fix in repairs cable lugs of size 16 to 25 sqmm complete all as specified and directed.
Supply & Fix 50 KVAR power capacitor, type MPP, 415/440V,50HZ, 3ph including removing unserviceable power capacitor complete all as specified
All as per Item No: 44 above but of capacity 25 KVAR
All as per Item No: 44 above but of capacity 20 KVAR
All as per Item No: 44 above but of capacity 15 KVAR
All as per Item No: 44 above but of capacity 10 KVAR
Ditto as per Item No: 44 above but of capacity 05 KVAR Make for Item No: 44 to 49 : L&T/ Havells/Neptune
Supply & Fix Capacitor duty type Contactors, 415 volts Suitable for 50 KVAR capacitor including removing the old unserviceable item all as specified and directed.
All as per Item No 50 above but suitable to 25KVAR Capacitor
All as per Item No 50 above but suitable to 20KVAR Capacitor
All as per Item No 50 above but suitable to 15KVAR Capacitor
All as per Item No 50 above but suitable to 10KVAR Capacitor
All as per Item No 50 above but suitable to 05KVAR Capacitor
Supply & Fix Control relay (Auxilary contactor), 4amps, 415 volts complete including removing unserviceable item all as specidied and directed.
Supply & Fix in repairs Auxilary Contact bolck (1NO + 1NC) for contactor complete including removing unserviceable item all as speicified and directed.
Supply & Fix in repairs HRC fuse Link 20 amps complete including removing unserviceable item all as speicified and directed.
Supply & Fix in repairs Cylindrical fuse 415 volts 6 amps
Supply & Fix in repairs APFC Relay 12 stage type complete with testing complete all as specified and as directed. Make : L&T/Havells/Secure/Neptune
Supply & Fix Digital type Power factor meter 3Phase (multi function meter) suitable to existing size and modifications to existing panel complete with testing including removing the unserviceable item. Make : L&T/Havells/Secure/Neptune
Supply & Fix current transformer 400/5A to 800/5A Class 1, VA 15 50Hz complete including removing unserviceable item all as specified and directed. Make : Kappa/L&T/C&S
M&L Programming the existing APFC relay 8 stage and testing control wiring, capacitors, contactors, MCB complete capacitor bank panel all as specified and directed.
Material and labour painting of HT/LT two pole structure 11 KV complete by scrapping the existing old paint and making the surfaces smooth including cross arms bracings complete and applying two coats of synthetic aluminium paint complete all as specified and directed.
All as per Item No. 64 above but four pole structure Make of Paint for item No. 64 & 65 : Asian/Nerolac/Berger
Labour for cutting the bushes and plants grown near the substation/ structures premises using necessary tools and plants and removing the plants from the root level at any depth and cleaning the premises completely and making good the site suitable for spreading the stone aggregate including disposing all the waste to a distance not exc 50M form the site all as directed by the Engr-in-Charge.
Removing the existing stone aggregate of any size from the sub stations and shifting to the place inside the substation/ structure premises for spreading of the new aggregate in substation/structure premises and relaying the old aggregate along with new after cleaning complete all as directed. Note: Stone crush material will be measured and paid separately under resp Sch A items.
M&L for spreading the 40mm coarse aggregate in various sub stations/Structure premises and other locations complete all as directed.
Cutting of trees and tree branches of girth up to 20cm and to a radius of 3M all around LT/HT OH line complete all as directed. Note: The distance between two adjacent poles will be considered as one span
M&L for LT line zig zag PVC spacer including replacing the broken u/s spacers and necessary ladder arrangement should be made by the contractor during replacing as required at site.
Supply, fix, in repairs testing and commissioning of Air break gang operated switch, triple pole mechanically operated out door type with all fittings/accessories mounted on and including 11 KV HT polymeric insulators and steel channel frame, GI operating rod 25 mm dia of suitable length with operating mechanism worked from ground level vertically operated including locking arrangement for operating handle complete suitable for current rating of 400 Amps HT 11 KV working pressure all as specified and directed.
Repairs to AB switch (GOD) including replacement of male and female contacts, bolts & nuts and cleaning the carbon/ dust deposited on the switch contact surfaces and applying mineral jelly, oil grease to the moving/rotating parts etc after cleaning, removing carbon deposits including testing and commissioning the same for operation complete all as directed by Engr-in-charge. Note: The repairs to three poles of AB switch will be measured as on job.
M&L in replacement the tinned copper fuse wire single pole of 11000 volts grade of rating 25Amps and up to 50Amps.
M&L in replacement the tinned copper fuse wire single pole of 11000 volts grade of rating 50 Amps up to 100Amps.
S&F in repairs rust free Acrylic Danger notice plate duly marked voltage danger and conventional skull and bones in signal red colour written in one local language and english with retro reflective stickering and fixing with GI/MS. clamps, bolts and nuts of approved size, for LT 440volts all as specified.
All as per item no 75 above but for HT 11000 volts.
Supply, Install in repairs and erect steel tubular swaged pole type 410 SP-55 of 9.0 mtrs long complete with cast iron base plate finial taper plug, pole cap, bolts, nuts and washers pole made out of MS tubing confirming to IS-2713 Part-II, including drilling of holes painting with two coats of bituminous paint internally and externally embedded portion in ground/concrete and painting to exposed surfaces with two coats aluminium paint and one coat of red oxide primer, including removal of old unserviceable pole by dismantling old concrete quoted rate complete all as specified and directed. Note :- Excavation/Earth work in any type of soil/ strata PCC foundation, coping of poles, cross arms, clamps shall be measured and paid separately. Make :- M/s Bombay Tubes/ M/s Jindal Steel Products/ M/s India Tubes Co/ M/s Bharat poles/ National Tubing
Material and Labour for PCC 1:3:6 type C2 with 40 mm stone aggregate for foundation of poles/transformer bed/cable duct foundation/panel base/ chain link supports etc including necessary form work etc complete all as specified and directed.
Material and Labour for PCC 1:2:4 type B1 with 20 mm graded stone aggregate for coping of pole including necessary form work etc complete all as specified and directed.
Supply & fixing silica gel suitable for 5 MVA 33/11 KV transformer and removing unserviceable silica gel complete all as specified and directed.
M&L in repairs for existing LT panel control wiring, capacitors, contactors, MCB complete panel all testing should be conducted infront of engr-in-charge for job satisfactory complete all as specified and directed.
Supply & fixing in repairs GI perforated cable trays made with high grade strength sheet steel having minimum thickness of 1.6mm of width 200 mm and height not less than 25mm and depth as per the site requirement and fixing on angle supports or threaded rods suspended from ceilings as required at site all as specified and directed.
CHAVA CONSTRUCTIONS AND ELECTRICAL PROJECTS
Maruthi international
M/S. ELECTROPOWER TECHNOLOGIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .