EXECUTIVE ENGINEER(CIVIL)
O/o the Executive Engineer (Civil), BSNL Civil Division, Jamshedpur at Dhanbad, 2nd floor, CTO building, Dhanbad-826001
R and M of 08 nos. RTT ... at (1) Kalimati Sakchi,(2) Shitlamata Mandir Bhalubasa(3 Naya line Sonari,(4)Shyam Takies BTS,(5)Mango Bus stand,(6)Jay Prabha Complex,(7)Adityapur -III in diff. location at JSR and(8)Gandhi Tola Chaibasa (Jamshedpur BA)
2023_BSNL_148624_1
16/NIT/EE(C)/CDJ/2022-23
Open Tender
Civil Works
Item Rate
60 days
Jamshedpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts officer (Cash), O/o GMTD, BSNL,Jamshedpur
₹8,036
31 Mar 2023
13 Mar 2023
24 Mar 2023
13 Mar 2023
21 Mar 2023
13 Mar 2023
Amount
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
a) 1:1½:3 (1 cement : 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
a) Hard drawn steel wire fabric
Finishing walls with water proofing cement paint of required shade :
a) New work (Two or more coats applied @ 3.84 kg/10 sqm).
Repairs to plaster of upto 12 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the foundation beam complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge.
a) With cement mortar 1:4 (1 cement : 4 fine sand)
Providing and fixing bamboo scaffolding system on the exterior side, up to four story height with staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
a) 75 mm average thickness
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
a) Bars up to 12 mm diameter
b) Bars above 12 mm diameter
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.
a) SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
Reparing of damage RCC walls, columns, pillars, pilasters, string courses, beams, Suspended floors, roofs, landings, Shelves,Chajjas,Lintels, balconies, window sill, Stair cases. vertical and horizontal fins individually or forming box louvers, facias and eaves boards etc.upto floor five level i/c cost of Centering Shuttering with Cement concrete 1:1:2 (1 Cement : 1 Coarse sand : 2 Stone aggregate 12.5 mm to 6 mm nomoial size) and top finishing with 6mm Cement plaster 1:3 (1 Cement : 3 Fine sand) excluding the cost of scaffolding as per direction & satisfaction of E-in-C.
a) 75 mm average thickness of repairing
Checking and re-tightening of all nuts and bolts of existing RTT mobile tower including replacing the missing/damaged nuts, bolts & washers etc. All complete as per the direction and satisfaction of E.I.C. (Missing/damaged Nuts, bolts and washers etc. to be paid for separetely)
Supply of galvanised Nuts & bolts i/c washers of required size as per direction and satisfction of Engineer-in-charge.
Painting of erected RTTmobile tower structure with high gloss synthetic enamel paint of approved brand and manufacture and of required shade and pattern of approved brand and manufacture all complete as per direction of Engineer-in-Charge. (One or more coat on old work)
Extra labour charges for working on very difficult, not easily accessible and in un-natural work site position for repairing of RTT foundation beam, columns etc. situated upto floor five level and above with necessary safety arrangement etc. as per direction of the Engineer-in-Charge.
Deduction for using scaffolding
Repairs to plaster of thickness 12 mm to 20 mm in patches
Cement concrete up to floor V level
Applying bonding coat..
SRIJAN CONSTRUCTION & CONSULTANCY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .