Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹9.1 L+₹25,865 (2.93%)Rejected-Finance BINDODPUR KALIBARI KATIHAR 854105 BIHAR | KATIHAR | KATIHAR | BIHAR | 854105 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹9.2 L+₹30,992 (3.51%)Rejected-Finance | L3 | Rejected-Finance Higher bid value |
Tender Value
₹8.2 L
EMD Value
₹16,400
Closing Date
4 Jun 2020, 6:00 pmClosed
AGE (I) (AF) PURNEA
AGE (I) (AF) PURNEA,CHUNAPUR,PURNEA
REPAIR/REPACEMENT OF LIGHTING ARRESTER,EARTHING AND ALLIED WORKS AT MOUZA DALAN AND SIRSA CAMP AT ARMY STATION KATIHAR UNDER AGE (I) (AF) PURNEA
2020_MES_343803_1
C/8842/E8
Open Tender
Civil Works
Item Rate
150 days
AGE (I) (AF) PURNEA
AS PER NIT
7 documents required · 7 mandatory
₹500
AGE I AF PURNEA
₹16,400
Yes
16 Jun 2020
9 May 2020
9 Jun 2020
9 May 2020
4 Jun 2020
22 May 2020
Amount
M&L for Taking down old unserviceable earth plate electrode and PCC earth pit, and all relevent item of earthing buried in ground of any type and size all as specified and directed by Engr- in- Charge.
M&L for Taking down old unserviceable earth continuity earthing lead removed from wall on batten or recess or buried in ground or conduit/ pipe etc of any type and size all as specified and directed by Engr- in- Charge.
Taking down oldunserviceable terminal block made of gun metal/ MS of any size and type all as specified and directed by Engr- in- Charge.
Taking down old unserviceable Air Termination , single pointed Aluminium/ copper rod of any type and size all as specified and directed by Engr- in- Charge.
M&L for Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper strip of size 20 x 3mm earth lead by means brazing after fixing of nuts, bolts, check nuts, washers of galvanised iron steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x 10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion after taking down old earthing complete all complete as specified and directed.
M&L in replacement earth continuty conductor or main earthing lead fixed to wall on batten or recess or burried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthig etc as required with copper strip of 20 x 3 mm with saddle & fixing screw etc for roof conductor and down conductor above ground.
M&L for Earthing complete with GI earth plate electrode of size 600x600x6.6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing.( GI wire upto 7.5m including testing consider in this item).
M&L in replacement earth continuity conductor fixed to wall on batten or recess or chessis or burried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as reqd 4.00mm dia galvanised iron or steel wire all as specified and directed by Engr- in- Charge.
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to 25x4 mm GI iron strip earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing.( GI wire upto 7.5m including testing consider in this item).
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or chasses or burried in ground or drawn in conduit/pipe light grade or fixed to poles or any other indicated situation for loop eathing etc as required with 25x4 mm galvanised iron strip all as specified & directed by the Engr- in -Charge.
M&L in replacement test terminal block made of gun metal for phosphours bronze size 75x 75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex. Head screw all as specified and directed by Engr- in- Charge.
Labour only for cutting/ Trimming of tree branches whereever the branches touches OH line or come cross the street light of any size after disconnecting the electric supply all as directed by Engr- in-Charge.
M&L Air termination , single pointed copper rod 12mm dia 300 long as directed by Engr- in-Charge.
M&L in replacement GI Tubing Light grade 32 mm bore 1.5 Mtrs long fixed on roof vetically by means of base plate clamp nut-bolt 2 mm stay wire including PCC foundation complete all as specified and directed by Engr- in-Charge.
M&L for 40mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed. (MAKE: JINDAL/PRAKASH/SURYA)
M&L for fabrication of display board for earth pit nos. location and periodical test results for power circuit earthing, machinary earthing, lightening conductor earthing, made of GI shett 4.0 mm thick, rectangular welding on 12 mm dia rod of minimum height from ground level 45 cm including fixing in PCC 1:2:4 with 20cm X 20cm X 10cm grade aggregate foundation to be carried out at different location. dimension of board shall be 30 cm X 25 cm X 1cm. The instruction shall be written black painted board in white letters not less than 2" size for all type of boards complete all as specified and directed by the Engineer-in-charge. Note : (a) All necessary GI sheet, aluminium screws and PCC works etc are deemed to the rate qioted by the contracor. (b) The fabrication of condents on the screen printing should be collected before printing the board from Engineer-in-charge.
M&L for cement concrete PCC 1:3:6 type C-2 using 40mm graded stone aggregate in filling foundations and mass concrete complete including necessary form work foundation complete all as specified and as directed .
Supply & Installation of Advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED( 80-100)microns with pure Zinc (99.9%) & ALLOY COATING (200-250)microns. Earthing System confirming IS 3034. The outer and inner pipe should be 76.2 mm & 41.9 mm 3mtrs Length, Zinc coated with additional special Alloy coating 300mm on the topside for additional corrosion protection of the Terminal. The annular space between the pipes being filled up with COMPACT FILL(CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity The job includes digging the pits and refilling the same by Electrodite/Conductolite Back Fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having RoHS Certification from NABL accredited lab. Good earth is to be arranged to fill the excavated pits by mixing the same with BFC 2 bags. including FRP (Fiber reinforced plastic) light weight, high mechanical strength, chemical resistance with detachable easy locking lid of size 250mm X 250mm of thickness 2mm, complete all as specified and directed. Note 1- chemical earthing will be loop of 3 earthing connected centrally with copper earth plate 90x60cmx5mm & copper earth strip 32 x6mm. Note 2. cost Required length of copper strip has been included. Note:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount.
M/S. R.D. Construction
M/s. Rakesh Roshan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .