| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹31.9 L+₹22,890 (0.72%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹32.9 L+₹1.3 L (3.97%)Rejected-AOC N A | NA | NA | 121004 | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹36.5 L+₹4.8 L (15.3%)Rejected-AOC | L4 | Rejected-AOC Not L1 Bidder |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
2 Nov 2024, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
REPAIR MAINT REROUTING OF RISING MAIN AND CI DI GI PIPE LINE NETWORK INCLUDING CONNECTED WORKS AT 35 INF BDE AREA 200 DUS OTM I SHANKAR VIHAR OTM II III 180 ORS BANA SINGH ENCLAVE 1 SIGNAL ENCLAVE ANUJ VIHAR YOGINDER VIHAR AND SUBROTO PARK AND OTHER
2024_MES_678197_1
GE/WS/Token-23 OF 2024-25
Open Tender
Civil Works
Item Rate
330 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹94,000
Yes
19 Dec 2024
5 Oct 2024
4 Nov 2024
5 Oct 2024
2 Nov 2024
19 Oct 2024
Amount
Excavation in trenches not exc.1.5m wide and not exc. 1.5m in depth including getting out in soft/loose/ Hard soil complete all as specified and directed.
Excavation in trenches by cutting of road crossing PCC hard standing for taking out/laying of pipe including making good the existing surfaces with same finish to match the original finish and remove the rubbish / PCC from road to out side MoD land at his own arrangement complete complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and directed
M&L Boring holes under road pavement by bocky manually in any type of soil upto 200 mm bore complete all as specified and directed by Engr-in-Charge. (Note:-Location & depth of boring from GL shall be as directed by EIC
Taking up Cast Iron/Ductile Iron water mains (including all fittings) with spigot & socket ends and lead/tyton joints including burning out lead joints and recovering lead all as specified and directed by Engr-in-charge of the following sizes :- (Note:- (a) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of CI/DI pipe in 'RM' and lead in 'KG'shall be taken into account and attach with RAR/F Bill) (b) Excavation and earth work shall be measured and paid seprately under respective items.
80 / 100 mm bore
150 mm bore
200 mm bore
250 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
M&L for CI/DI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of following sizes confirming to IS: 1538-1993 complete all as specified and directed by Engr-in-Charge. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of fittings in weight (KG) shall be taken into account and attach with RAR/F Bill)
100 to 150mm bore
200mm to 300mm bore
Material and labour for Run lead joint including jointing material for CI/DI pipe of following size/bore:- (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV for old lead in weight (KG) shall be taken into account and attach with RAR/F Bill)
100 mm bore
150 mm bore
200 mm bore
M&L for excavation in any type of soil through trenchless technology by HDD (Horizontal directional drilling method) including preparing and setting up the plant and equipment .Preparing new pipe work material including all related civil work and mechanical work like excavation, shoring/strutting etc drilling, stringing, reaming and pulling back the new pipe work on the path alignment proper disposal of drilling fluid and ground penetrating radar survey to protect any exiting utilities at the pipe installation location restoration of site agter completion all inclusive as per and STT IS No.2.3.2.2.2.2. second edition 2008 code of pactice for trenchless technology suiting Indian condition for making horizontal bore of size 350mm dia suitable for HDPE pipe insertion under road crossing /hard standing including providing new HDPE pipe 250 mm nominal dia of 28 mm wall thickness of grade PE 80 for protection of MS/DI pipe of size 150mm to any depth by manually or any means complete all as specified and directed. Note:- (a) MS Pipe/DI will be measured and paid for seprately under respective items. (b) Permission required from civil authrority/department prior to executing the work is the responsibility of contractor and the cost for the same shall be deemed to be included in unit rate quoted by the contractor. (c) Site layout for providing trenchless technology drilling by HDD shall be approved by GE before execution of work.
Supply, Laying, Jointing, Welding, Testing and Commisioning of MS Pipe (Heavy Class 'C') as per IS:1239 of following size laid in trenches or in Horizontal/Vertical/Inclined position or laying in floors for connection of suction/delivery line including taking out the old unserviceable pipes complete all as specified and as directed. Notes : (a) MS Flanges and Fabrication work shall be measured and paid separately. (b) Earth work and Joints shall be measured and paid separetely (c) Layout plan for laying of MS pipe shall be given by EIC in writing. (d) MS pipe whole quantity of tender shall be procured by contractor in one time and the same will be paid in 1st RAR as material laying at site. (e) Piece meal site for laying of pipe shall be given by EIC and contractor arrange to transport the MS pipe accordingly at his own arrangement. No any additional payment for transportation will be given to contractor. Contractors are requested to quote rate accordingly. (f) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.
80 mm bore
100 mm bore
150mm bore
200 mm bore
250 mm bore
300 mm bore
Supplying and fixing, MS flanges of following sizes not less than 16 mm thick duly welded on ends of MS pipe all as specified and directed by Engr-in-Charge. (Note:- Old U/s flange material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
M&L for Flanged Joints with rubber or fibre board gasket in replacement including nuts, bolts and double washers of following sizes complete all as specified and directed by Engr-in-Charge. (Note:- (i) Old U/s PVC / rubber scrap obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill. (ii) Excavation & earth work shall be measured and paid seperately. (iii) Rubber gasket (Tyton) joints as applicable in item No (7) will not be measured under this item. This item will be applicable for repair / replacement of U/s Joints only.)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
Supplying & Fixing , jointing and testing of cast iron Sluice Valve ISI marked (PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets of following sizes including taking down of existing sluice valve with all fittings complete all as specified and as directed. (Note:- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply, fixing, jointing and testing of Cast iron Non Return valve of following sizes without by pass arrangement , Swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRV complete all as specified and as directed at site by the Engineer-in-Charge. (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of item.) (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of NRV in numbers (EACH) shall be taken into account and attach with RAR/F Bill)
80mm bore
100mm bore
150mm bore
200mm bore
S&F CI Foot valve of following size, rating PN 0.2 Flanged ends, Swing type opration with rubber sheet as per IS-4038 -1986 including taking out unserviceable of following sizes complete all as specified and directed by Engineer-in-Charge. Note (i) :- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this items. (ii) Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Supply, installation and testing in replacement of unserviceable flanged ends Water Meter woltman type, including testing and making good connection with flanged ends, with gasket rubber sheet and nut & bolts etc ISI Marked fixing in horizontal/incline/vertical position, including taking out unserviceable water meter of following sizes complete all as specified and as directed at site by the Engineer-in-Charge. (Note:- (i) Flange Joints Including Jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s water meter obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of water meter in number (EACH) shall be taken into account and attach with RAR/F Bill)
100 mm bore
150 mm bore
Taking up or down GI tubing and connections of the following sizes from trenches / wall / floor including cleaning for refixing or removal complete all as specified and as directed by Engr-in-Charge :-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Re-fixing/re-laying only GI pipe medium grade with all fittings fixed complete to walls and ceiling or in floors on old/new position as directed of following sizes :- (Note:- Old serviceable material GI pipe shall be used after cleaning of pipe.)
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply and fixing /Laying tubing GI pipe medium grade IS 1239 (Part I)-2004 marked including all fittings laid in trenches/wall/floor etc in old/new position complete all as specified and directed of following sizes:- (Note:- Old U/s GI Pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of water meter in weight (KG) shall be taken into account and attach with RAR/F Bill)
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F Gun metal gate valve with iron wheel head screwed both iron iron pipe ISI Marked as per IS 778 of following sizes including taking out unserviceable gate valve complete all as specified and directed :- (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of gun metal gate valve in weight (KG) shall be taken into account and attach with RAR/F Bill)
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Labour for cutting, welding of CI /DI/GI/MS pipe in position for reducing to required length for insertion of new tees, branches, buterfly valve (wafer type) etc of upto 300 mm bore complete all as specified and directed by Engr-in-Charge.
Taking out foot valve, NRV, Stainer and refixing the same after refacing, regrinding , including replacement of rubber gasket , nut bolts including painting of following sizes complete all as specified and directed .
80mm bore
100 mm bore
150 mm bore
200 mm bore
Opening of existing sluice valve of following size including opening of gland cover taking out with stem nut of brass or of stainless steel & refixing the same after with & including replacement of rubber packing, nut & bolts, glands dori etc complete all as specified and as directed. (Note :- Any new spare parts like stem, stem nuts, gland plate of required size shall be measured and paid separately under respecitve items.)
80mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only stem nut made out of stainless steel suitable to match with existing sluice valve of following size complete all as specified and as directed.
80mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only stem made out of stainless steel suitable to match with existing sluice valve of following size complete all as specified and as directed.
80mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only gland plate made of cast iron suitable to match with existing sluice valve of following size complete all as specified and as directed.
80mm bore
100 mm bore
150 mm bore
200 mm bore
Supply, installation and testing flanged ends strainer/dirt box rating (PN 1.0) of following sizes with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/ vertical position, including taking out unsv strainer/dirt box complete all as directed at site by the Engr-in-Charge. Note :- (i) Flange joints including jointing materials shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of strainer/dirt box in weight (KG) shall be taken into account and attach with RAR/F Bill)
100 mm bore
150 mm bore
200 mm bore
Supplying, fixing, jointing and testing in replacement of cast iron Air release valve with two air outlets, confirming to IS , flanged ends complete including taking out unserviceable ARV of following sizes including taking down of existing Air release valve complete all as specified and as directed . (Note:- Old unserviceable Air release valve shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
80 mm bore
100 mm bore
S&F in replacement of electromagnetic Flow meter of size 80mm with inline monitoring, IP 68 flow sensor protection, IP 65 display enclosure, accuracy +/- 0.5% of MV, IP 65 display enclosure complete all as specified and directed.
Material and labour for Fabrication, welding and fixing of MS work made out of MS sheet not more than 3 mm thick of any size or MS angle/flat of any size as required at site for repair/replacement of valve pit cover / Sump manhole cover, stair case steps, sign board and all other iron works including painting two coats with synthetic enamel paints over a coat of red oxide primer complete all as specified and as directed at site. (Note:- Old U/s MS Work material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Labour Only for run lead joint by using old lead and new spurn yarn for CI/DI Pipe of following sizes complete all as specified and as directed .
100 mm bore
150 mm bore
200 mm bore
M&L for testing of drinking water being collected from local source (bore wells/shallow wells/under ground sumps) one test in one month for one source in the area under AGE (U) W/S No-III as directed by EIC in the area under AGE(U) W/S No III and submission of detailed test report to the office of Engineer-in-Charge. (a) Collection of water from different sources of water ie Sump, bore wells & shallow wells in sterilized bottle and testing in Govt Approved laboratory as mentioned in specification. (b) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, Lead, PH value TDS total hardness, iron, chloride, fluride and residual free chlorine and Bacteriological total Collie from organisms per 100 ml (MPN) and E Collie in 100 ml) and submission to this office with specific recommendation regarding suitability of water for drinking purpose. Note :- Rate quoted shall deemed to be included for : - (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source(sump/bore well/shallow wells) (iii) Contractor will required to visit the site of AGE (U) W/S-III area for working out number of sources i.e borewells/shallow wells/under ground sumps etc. Approximately 30 Number of tests will be carried out in eleven months period (iv) Period of testing of water sources is of 11 (Eleven) months from the commencement of work. (v) Mode of payment: - Payment will be made after completion of work as one JOB for 11 (Eleven) months for number of tests. Part payment will be allowed after dividing number of months in quoted unit rate.
Rahul Enterprises (BID ID -3147841)
M/s Sree Baba Traders (BID ID -3150758)
Anandeshwar Enterprises (BID ID -3156122)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .