Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 14 BILASIPARA P O P S BILASIPARA DIST DHUBRI ASSAM PIN 783348 | DHUBRI | ASSAM | 783348 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical NON RESPONSIVE |
Tender Value
Refer Docs
EMD Value
₹3.4 Cr
Closing Date
22 May 2023, 5:00 pmClosed
Nodal Officer
e-Procurement Cell, Jharkhand State Building Construction Corporation Ltd., Beside Jharkhand Mantralaya Dhurwa, Ranchi-834004.
Remaining work of Construction of Medical College and Up gradation of District Hospital at Koderma
2023_JSBCC_68298_1
JSBCCL/151/2022-23
Open Tender
Civil Works - Buildings
900 days
Koderma
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
Yes
JSBCCL
₹3.4 Cr
JSBCCL
6 Jul 2023
29 Mar 2023
24 May 2023
29 Mar 2023
22 May 2023
29 Mar 2023
3 Apr 2023
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
Ordinary rock
Hard rock (blasting prohibited)
Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposing of surplus excavated soil as directed, within lead of 50m.
All kinds of soil
Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m:
Ordinary rock
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Hard Rock
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
All kinds of soil
Ordinary or hard rock
Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50m and lift upto 1.5 m.all complete as per building specification and direction of E/I ( mode of measurement compacted volume).
ProvidIng coarse clean sand In filling in foundation trenches or In plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour. royalty and taxes all complete as per building specification and direction of Ell ( Mode of measurement compacted volume).
C O N C R E T E W O R K
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of grade excluding the cost of centering and shuttering - all work up to plinth level
1:5:10 (1 cement : 5 coarse sand : 10 graded ston aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor five level, excluding the cost of centring, shuttering and finishing :
1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
REINFORCED CEMENT CONCRETE
Centering and shuttering including strutting, propping etc. and removal of form for all heights
Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string course etc
Suspended floors, roofs, landings, balconies and access platform.
Shelves ( Cast in situ )
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Extra for shuttering in circular work (20% of respective centering and shuttering items)
beams
Columns,
Stairs, (excluding landings) except spiral-staircases.
Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like.
Edges of slabs and breaks in floors and walls.
Under 20 cm wide
Weather shade, Chajjas, corbels etc., including edges.
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Providing Tor steel reinforcement of 8mm. dia rods as per approved design and drawing -do- -do- TMT Fe 500 {Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels Ltd. Bokaro and Vizag (RINL)}
Providing Tor steel reinforcement of 10mm,12mm & 16 mm. dia bars as per approved design and drawing -do- -do-
a) 10 mm (TMT coiI Fe 500) {Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels Ltd. Bokaro and Vizag (RINL)}
b) 12 mm (TMT coiI Fe 500) {Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels Ltd. Bokaro and Vizag (RINL)}
c) 16 mm (TMT coiI Fe 500) {Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels Ltd. Bokaro and Vizag (RINL)}
Providing Tor steel, reinforcement of 20mm, 25mm, 28mm, 32mm dia bars as per approved design and drawing-do- -do-
20/25 mm dia,TMT bar Fe 5OO {Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels Ltd. Bokaro and Vizag (RINL)}
28/32 mm dia,TMT bar Fe 5OO {Only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel steels Ltd. Bokaro and Vizag (RINL)}
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineering in charge. (Note :- Cement content considered in this item is @330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately)
All works upto plinth level
All works above plinth level upto floor V level
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level
Concrete of M30 grade with minimum cement content of 350 kg /cum
All works above plinth level upto floor V level
Concrete of M30 grade with minimum cement content of 350 kg /cum
Providing M-30 grade concrete instead of M-25 grade BMC / RMC. (Note:- Cement content considered in M-30 is @ 340 kg/ kg/cum)
Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof.
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall confirm to ASTM 6063)
Floor Joint of 100 mm gap
Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).
Wall Joint of 100 mm gap
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre- engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063).
Roof Joint of 100 mm gap
B R I C K W O R K (A)
Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 Including providing 10 mm thick mortar joints. cost of screentng materials raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 75 A brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 Including providing 10 mm thick mortar joints. cost of screentng materials sacffolding, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 100 A brick Work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth. curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 100 mm/ 125 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening matenals, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS : 12894, in super structure above plinth and upto floor V level.
Cement mortar 1 : 4 (1 cement : 4 coarse sand)
Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means.
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
M A R B L E W O R K
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Area of slab up to 0.50 sqm.
Area of slab over 0.50 sqm.
Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Granite work.
Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with aluminium fittiings such as hinges, tower bolts, handle, cleast and sand blocks and taxes all complete as per building specification and direction of E/I.
Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush door shutter in doors and windows with black board core bended with high quality phenol formal dehydes synthetic resin both side commercial veneered of standard make with oxidized iron fittings such as hinges, tower bolts, handle, cleast and sand blocks and taxes all complete as per building specification and direction of E/I.
25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured).
Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick (weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
Float glass panes
5.0 mm thick glass panes (weight not less than 12.5 kg per sqm)
Extra for providing vision panel not exceeding 0.1 sum in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) :
Rectangular or square.
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Single rubber stopper
Twin rubber stopper
Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
300 mm sliding door bolt
250 mm sliding door bolt
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
250 mm tower bolt
150 mm tower bolt
100 mm tower bolt
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
100 mm door handle with plate
75 mm door handle with plate
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete.
Size 40 mm
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete.
Triple strip vertical type
Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate/ Square bar as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.)
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
With 12 mm mild steel U beading
Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately) Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
uPVC Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
1.0 mm thick
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter. The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634- 1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threadedstar headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).
Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Frame size 50 x 100 mm
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
35 mm thick
S T E E L W O R K
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes
Electric resistance or induction butt welded tubes
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
Profile B
Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 part 1 and M.S. top cover of required thickness for rolling shutters.
80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rolling shutters.
Exceeding 10.00 sqm and upto 16.80 sqm in the area
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators side /top /centre hung with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer , but excluding the cost of other fittings, complete all as per approved design (sectional weight of only steel members shall be measured for payment).
10.11.1 Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete lock 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
M.S. tube
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
F L O O R I N G
Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :
Light shade pigment using white cement
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.
In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)
Acid and alkali resistant tile
In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)
Acid and alkali resistant tile
62 mm thick cement concrete flooring with concrete hardener topping,under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm.
Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness.
Providing and laying Double Charge Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622/ ISO 13006, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand ), jointing with grey cement slurray @ 3.3 k.g / sqm including grouting the joints with white cement and matching pigments etc., complete size of tile 600 x 600 mm .
Size of Tile 600x600 mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
110 mm diameter
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
Size of Tile 600x600 mm
Providing and laying 25mm thick kotah stone slab flooring of approved size, texture and colour over 19mm. thick base of lime morter (1:1:1) (lime putty:surkhi:coarse sand) laid over and Jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandium stone including cost of curing, taxes and royalty all complete as per building speclflcationand direction of Ell.
iv) 600X600 mm Size
Providing and laying 25mm thick kotah stone tiles In risers of steps, skirting, and pillars of approved size, texture and colour laid over 12mm. thick cement mortar (1:3) and joined with grey cement slurry mixed with pigment to match the shade of the slab including rubbing to granolilthic finish with approved quality -do-
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :
Raj Nagar plain
Providing and laying Ceramic (Anti Skid) glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Vitrified (rectified) tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, (type II adhesive) in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
Size of Tile 1200x300 mm X 15 MM
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
Providing & fixing in position Phenol bonded Bamboo wood flooring with planks of sizes 14mm thick, 1800mm length (minimum) and 130 mm wide(minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC). The flooring shall be fixed with tongue and groove interlocking system, with underlayment of 4mm thick expanded poly ethylene foam sheets having density 40kg/cum, over prepared surface with necessary quarter round planks of size 1900mm x 18mm and door reducer of size 1900mm x 44mm, wherever required. The bomboowood planks shall have minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of Engineer in-charge.
Providing & fixing in position Phenol bonded Bamboo wood in wall skirting with planks of sizes 14mm thick, 1900mm length (minimum) and 85mm wide(minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC). The skirting shall be fixed with SS screws & rawl plugs, over underlayment of 4mm thick, expanded polyethylene foam sheets having 40kg/cum density over prepared surface. The bamboowood planks shall have minimum density of 1000Kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge.
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622, of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineer- in-Charge
60mm thick Cement concrete paver block of M-35 grade with approved colour, design & pattern.
In rows 5 cm apart in both directions
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
Extra for Kota stone/ sand stone in treads of steps and risers usingsingle length up to 1.05 metre.
Extra for pre finished nosing to treads of steps of marble/ granite stone.
Extra for marble/ granite stone flooring in treads of steps and risers using single length up to 2.00 metre.
Roofing work
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion.
110 mm bend
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Shoe (Plain)
110 mm Shoe
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Ridges plain (500 - 600mm)
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum moisture resistant board
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).
6 mm thick Cement fiber board as per IS: 14862
Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :
GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing.
F I N I S H I N G
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Neat cement punning.
15 mm cement plaster on rough side of single or half brick wall of mix:
1:6 (1 cement: 6 coarse sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Extra for plaster work over exterior surface for each consecutive floor above first floor including cost of scaffolding etc. all complete as per direction of E/I.
Making 6x6mm grooves in plaster surface over walls truly horizontal of vertical as specified at regular intervals, at all heights including cleaning, finishing, scaffolding and curing with all leads and lifts of water all complete as per building specification and direction of E/I.
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone of fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I
providing two coat of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty whwerever required scaff folding washing of floors and texes all complete as per building specification and dircetion of E/I
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Two coats
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
White washing with lime to give an even shade :
New work (three or more coats)
Painting steel work with synthetic enamel paint of approved brand and manufacture to give an even shade, two or more coats.
French spirit polishing :
Two or more coats on new works including a coat of wood filler
Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing two coat of synthetic enamel paint of approved shade and make over new wooden surface do/-
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Two coats
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Providing and fixing of façade at all heights with extruded hollow Clay / Terracotta ventilated rainscreen tiles of height 250/ 300/ 400mm and length of 595 mm of approved texture,design and pattern having Flexural Strength/ Modulus of Rupture of ? 14 N/m² and maximum water absorption of 10% tested as per ISO 10545-4:2004(E) and ISO 10545-3:1995 respectively in true level fixed to a supporting aluminium framework(Alloy 6063 T5/T6) consisting of vertical 'T' (for intermediates)/ 'L'(for ends/ termination)/ Tubular sections (at corners)of size 80x60x2mm/ 40x60x2mm/ 40x40x2mm respectively, spaced at maximum spacing of 600mm c/c matching to the tile vertical grid, and horizontal aluminium 'C'-clamps of size 56x25x2mm thickness of length 150mm at junction of tiles and of length 75mm at wall ends/ corners fixed on top of the vertical sections at spacing of 250/ 300/ 400mm c/c matching to the tile horizontal grid with two numbers of self-drilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers.The vertical 'T'/'L/ Tubular' sections shall be fixed to the wall using HDG (hot-dip-galvanized) steel L-brackets (galvanizing thickness of minimum 80 microns)of size 110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mm at outer corners and stainless steel grade 304,M10 full threaded anchor fasteners with nylon sleeve 100mm long (for brick work) and M8 expansion anchor fasteners 75mm long for concrete surface, spacing of brackets to be based on a structural/ static calculation.
The brackets shall be of length 175mm at junction of two vertical aluminium profiles and of length 100mm at intermediate points of vertical profiles and shall be fixed to the vertical aluminium T / L / Tubular profiles using two numbers self-drilling/ self-tapping SS screws of size 5.5x25mm with EPDM washers. EPDM gaskets to be fixed in between brackets and vertical profiles. The tiles shall be mounted on the ‘C’ clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be additionally secured to the horizontal ‘C’ clamps using special SS clips of required size which shall be inserted and pressed into position on the ‘C’ clamps holding the tiles and the cut-tiles shall be glued at points to the horizontal ‘C’ clamps by using MS Polymer sealant adhesive. Thevertical joint open groove between two adjacent tiles shall be 5mm. The tiles and system shall be designed to resist wind load as per IS 875 (Part 3) according to different zones. The tiles shall be installed using the ventilated rain screen principle with provision for natural ventilation of the space between the façade tiles and the structural wall. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in-Charge. Note : Scaffolding wherever required to be paid separately.
With 16mm thickness (+/- 10%) terracotta tiles of other than grey colors
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
In cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area 3 sq. metres and below
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles 10 mm to 25 mm
Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Brick Coba
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
Embankment Construction with Material Obtained from Borrow Pits (Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)
Rolling with vibratory roller
Plant Mix Method (Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 )
for grading- I Material
for grading- II Material
for grading-III Material
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Supplying and stacking at site.
90 mm to 45 mm size stone aggregate
63 mm to 45 mm size stone aggregate
53 mm to 22.4 mm size stone aggregate
Stone screening 13.2 mm nominal size (Type A)
Stone screening 11.2 mm nominal size (Type B)
Red bajri
Good earth
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
"Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints ( 10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars not to be paid separately).
Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.
Cement concrete prepared with batch mixing machine
Footpaths and Separators (Construction of footpath/separator by providing a 150 mm compacted granular sub base as per clause 401 and 25 mm thick cement concrete grade M15, over laid with precast concrete tiles in cement mortar 1:3 including provision of all drainage arrangements but excluding kerb channel.)
Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)
Using Concrete Batching and Mixing Plant
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing)
90 cm equilateral triangle
60 cm equilateral triangle
60 cm circular
80 mm x 60 mm rectangular
60 cm x 45 cm rectangular
60 cm x 60 cm square
90 cm high octagon
Direction and Place Identification signs upto 0.9 sqm size board. (Providing and erecting direction and place identification retro-reflectorised sign asper IRC:67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing)
Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retro- reflectorised sign asper IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing)
Overhead Signs (Providing and erecting overhead signs with a corrosion resistant aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans)
Truss and Vertical Support
Aluminium alloy plate for over head sign
Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)
Painting on Steel Surfaces (Providing and applying two coats of ready mix paint of approved brand on steel surface after through cleaning of surface to give an even shade)
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.)
Kilo Metre Stone (Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc)
Ordinary Kilometer stone (Precast)
Road Delineators (Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide stripes, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and confirming toIRC-79 and the drawings.)
Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-20 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified)
M 20 grade concrete
Metal Beam Crash Barrier
Type - B, "THRIE" : Metal Beam Crash Barrier (Providing and erecting a "Thrie" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 2 m high with 1.15 m below ground level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a space of channel section 150 x 75 x 5 mm, 546 mm long complete as per clause 810)
Spreading of Sludge Farm Yard Manure or/and good Earth (Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately))
Grassing with ' Doobs' Grass (Grassing with 'Doobs' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed)
In rows 15 cm apart in either direction
In rows 7.5 cm apart in either direction
Making Lawns including Ploughing and Dragging with 'Swagha' Breaking of Clod (Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm)
Maintenance of Lawns or Turfing of Slopes (Maintenance of lawns or Turfing of slopes (rough grassing) for a period of one year including watering etc)
Turfing Lawns with Fine Grassing including Ploughing, Dressing (Turfing lawns with fine grassing including ploughing, dressing including breaking of clods, removal of rubbish, dressing and supplying doobs grass roots at 10 cm apart, including supplying and spreading of farm yard manure at rate of0.6 cum per 100 sqm)
Maintenance of Lawns with Fine Grassing for the First Year
a) Planting Permanent Hedges including Digging of Trenches (Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart)
Maintenance of Hedge for one year
a) Planting Flowering Plants and Shrubs in Central Verge
Maintenance of Flowering Plants and Shrubs in Central Verge for one Year
Planting of Trees and their Maintenance for one Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year)
Renovation Lawns including, Weeding, Forking the Ground, Top Dressing with Forked Soil (Renovation lawns including, weeding, forking the ground, top dressing with forked soil, watering and maintenance the lawns, for 30 days or more, till the grass forms a thick lawn, free from weeds, and fit for moving and disposal of rubbish as directed, including supplying good earth, if needed but excluding the cost of well decayed farm yard manure)
Supply at Site Well Decayed Farm Yard Manure (Supply at site of work well decayed farm yard manure, from any available source, approved by the engineer in charge including screening and stacking)
Tree Guard with MS Angle Iron and Steel Wire (Providing and fixing tree guard 0.60 metre square, 2.00 metre high fabricated with MS angle iron 30 x 30 x 3 mm, MS iron 25 x 3 mm and steel wire3 mm dia welded and fabricated as per design in two halves bolted together)
SANITARY INSTALLATIONS
Supplying , fitting and fixing vitreous white glazed earthen ware I.W.C of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I 'p' trap 15 liters C.I.pull and let go flushing cistren of names or other I.S.S. equivalent make , complete with all fitting , C.I.or C.C. brackets 32mm alkathene/P.V.C telescopic flush , pipe about 2 M long with one brass coupling and clamps GI ,chain and pull including supplying and fixing a pair of vitreous white glazed earthenware ware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less thane 50grms. 15mm P.V.C. connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coats of red oxide primer etc. all complete as per specification and direction of E/I.
(A) 580 mm. long
(b) With 12.5 lit. low level C.I. Cistem
Supply, fitting and fixing 40mm high vitreous white glazed earthen E.W.C with 'p' trap of parry hindustan or any other approved ISS make including supplying and fixing 15 liters CI mosquito proof low down flushing cistern of approved make with complete fittings with CI handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grams 15 mm PVC alkathene pipe 45 cm. long with brass coupling at both ends and white /black plastic solid state seal and lead of commander /cuckoo or other ISS with hinges or screws etc painting pipe and cistern etc with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/I
(ii) E.W.C. with 'S' trap
(a) 12.5 lit. low level C.I. Cistem
Supplying fitting and fixing flat back or angular, lipped front vitreous white glazed earthen ware urinal of Hindustan "Parry" or any other approved ISS make with 5 liters capacity C.I. automatic fulsing cistern of reliance for any other I.S.S. approved make with all fittings clamps, 15 mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grams 15 mm P.V.C /Alkthene pipe 450 mm long with bras coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint over a priming coat of red oxide cutting wall and floor, making good the same etc all complete as per specification and direction of E/I
(a) Flat back or standing corner (600mmx350mm)
Supplying and fitting and fixing viterous white glazed earthern ware wash hand basin of parry or Hindustan or any other I.S.S approved make supported or painted C.I. or R.S. brackets 32 mm C.I. brass waste, 15 mm dia C.I. body brass spindle stop cock of approved qaulity of weight not less than 350 grams, 32 mm P.V.C waste pipe 750 mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I
Supplying fitting and fixing H.C.I. pipes with ear of approved make confirming to I.S.I. 1729 including supplying nails and bobins short pieces, cutting loose collars,lead and yarn for making lead caulked joints, cutting pipes to size including earth work or scaffolding where necessary etc. all complete as per specification and direction of E/I.
(a) 100 mm dia
(b) 75 mm dia
Supplying and fixing H.C.I. fittings of approved make confirming to I.S.S. 1729 including supplying nails and bobines lead and yarn from making lead caulked joints including earth work or providing scaffolding as the case may be all complete as per specification and direction of E/I.
(A) H.C.I. single junction with door but without ear except socket
(i) 100 mm dia(wt. 10.5 Kg. app.)
(B) H.C.I Heal rest bend
(i) 100 mm dia(wt. 5.5 Kg. app.)
(C) 100 mm dia H.C.I. "P" Trap with
Anti Syphonage Horn (wt. 8.5 kg app.)
(D) H.C.I double junction with doorand ear
(i) 100 mm dia(wt. 15.5 Kg. app.)
(E) H.C.I. double inverted Jn.
(100 mm x 50 mm x 50 mm size)
(F) H. C. I. offsets with ear
(i) 100 mm dia (wt. 6 kg. app.)
(G) H.C.I. Bend with door and ear
(i) 100 mm dia (wt. 6.5 kg. app.)
(H) H.C.I. plain bend with ear
(i) 100 mm dia (wt. 5.5 kg. app.)
(J) Floor trap with grantings
(i) 100 mm dia
(K) Northon patent H.C.I. Cowel
(i) 100 mm dia (wt. 3.25 kg. app.)
(L) H.C.I. pass over
(i) 100 mm dia
Supplying all tools and labours and cutting chajja, Cornice, for laying H.C.I. pipes and making good the same as per specification and direction of E/I.
Cutting drain width wise above G.L. for laying H.C.I. pipe and restoring brick work in cement mortar (1:4) 12mm cement plaster in (1:4) with neat cement punning as per specification and direction of E/I.
Making holes in walls for laying H.C.I. pipes and restoring the same after pipe laying as per specification and direction of E/I.
(i) 125 mm dia
(ii) 250 mm dia
(v) R.C.C. Chajja
Supplying materials and labour for painting the exposed H.C.I. pipes and fittings with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.
(c) 80 mm dia
(c) 100 mm dia
Providing designation 75 A brick work in C.M (1:4) in foundation & plinth with approved quality of clean coarse sand of F.M 2 to 2.5 including providing 10mm thick mortar joints costs of screening, materials ,scafolding,rtaking out joints to 15mm depth curing, taxex and royalty all complete as per building specification and direction of E/I.
Provinding and fixing was basin wih C.I brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls whereever required :
White Vitreous China Wash basin size 550x400 mm with a 15mm CP Brass single hole basin mixer
Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.
Kitchen sink with drain board
510x1040 mm bowl depth 250mm
Kitchen sink withought drain board
610x 460mm bowl depth 200mm
Supply Installation, Testing & Commissioning of Response Indicator single LED / 2 LED.
Supply, Installation, Testing & Commissioning of 300 mm dia heavy duty exhaust fan for single phase 230 volt, 50HZ AC supply complete with motor, blades, frame, bracket, louver/ shutter etc as required. (HavellS Make, Cat No - Ventil Air - DSP or equivalent).
Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete
Flexible Pipe
32mm Dia
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Rectangular shape 1500x450mm
Providing and fixing MS holder bat clamps of approved design to pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc.
Providing and fixing PTMT Bottle Trap for Wash basin.
Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.
Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
Providing and fixing toilet paper holder :
C.P. brass
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in charge.
Providing and fixing white vitreous china laboratory sink with CI brackets , C.P brass chain with rubber plug 40 mm C.P brass waste and 40 mm CP brass trap with necessary C.P brass unions complete including painting of fittings and brackets , cutting and making good the wall wherever required :
Size 600x450x200 mm
Water Supply
Providing & Fixing of Garden hydrant outlet consisting 1 No. 25mm dia. Ball valve,( Brass) for connecting rubber hose, pipes & fittings.
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)
20 mm dia, nominal bore
25 mm dia, nominal bore
32 mm dia, nominal bore
40 mm dia, nominal bore
50 mm dia, nominal bore
65 mm dia, nominal bore
80 mm dia, nominal bore
Providing and fixing G.I. Pipes complete with G.I. Fittings and clamps. including cutting and making good the walls etc. required for waste connection from W.B. , A.S.P., Sump Rising main etc. Complete.
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Constructing masonry Chamber 60x45x50 cm,inside with 75 class designation brick work in cement mortar 1:5 (1 cement:5 fine sand) for water meter complete with C.I. Doble flap surface box 400x200x200mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.
With F.P.S. bricks
Providing and filling sand of garding zone V or coraser grade all round the pipes in external work
Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete.
25mm nominal bore
32mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931
15mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
15 mm dia nominal bore
Provide and fixing PTMT ball cock of approved quality, colour and make complete with epoxy coated aluminium rod with L.P/H.P.H.D. plastic ball
50 mm dia NB, 242mm long. Weighing not less than 1240 gms.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20 mm nominal bore
25 mm nominal bore
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved qaulity:
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931
15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.
15 mm nominal bore
Providing and fixing PTMT grating of approved quality, colour and make 125 mm nominal dia with 25 mm waste hole
Providing and fixing PTMT grating of approved quality, colour and make 125 mm nominal dia without waste hole
Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
Providing and fixing chlorinated poly vinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fitting, including fixing the pipewith clampsat 1 m spacing. This includesjointing of pipes &fittingwith one step CPVC solvent cement and cost ofcutting chases and making good the same including testing ofjoints complete as per direction of Engineer in Charge.(Concealed work including cutting chases and making good the walls etc.)
15mm nominal outer dia. Pipes.
20mm nominal outer dia. Pipes.
25mm nominal outer dia. Pipes.
32mm nominal outer dia. Pipes.
Constructing masonary chamber 30x30x50cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock with C.I. Surface box 100x100x75 mm ( inside) with hinged cover fixed in cement concrete slab 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement:5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design with F.P.S. bricks.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Circular Tank
Making connection of GI distribution branch with GI main of 50-80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete.
25 to 40 mm nominal bore
50 to 80 mm nominal bore
Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality
15 mm dia, nominal bore
20 mm dia, nominal bore
25 mm dia, nominal bore
32 mm dia, nominal bore
40 mm dia, nominal bore
50 mm dia, nominal bore
65 mm dia, nominal bore
80 mm dia, nominal bore
Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc.(External work)
25 mm dia nominal bore
32 mm dia nominal bore
Making connection of GI distribution branch with GI main following sizes by providing and fixing tee, including cutting and threading the pipe etc, complete
Coupling/Socket
50mm to 80mm nominal bore
Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. (Exposed on wall)
15 mm dia, nominal bore
20 mm dia, nominal bore
25 mm dia, nominal bore
32 mm dia, nominal bore
40 mm dia, nominal bore
50 mm dia, nominal bore
EXTERNAL SEWERAGE & DRAINAGE INSTALLATIONS
Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.
Drainage Work
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) alround 100mm dia. SW waste pipes including bed concrete as per standard design
Providing & fixing in position precast RCC manhole cover and frame of reqd. shape and approved quality.
Circular shape 560 internal dia.
Providing laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.
150 mm diameter
200 mm diameter
250 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) alround SW pipes including bed concrete as per standard design.
150 mm diameter
200 mm diameter
250 mm diameter
Providing and fixing square mouth SW gully trap grade ‘A’ complete CI grating brick masonry chamber with bricks of class designation 75 and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. (COVER MIN. 4.5 KG & FRAME MIN.2.7 KG )
180x150mm size P type With FPS bricks
Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.
150 mm dia RCC pipe
250 mm dia RCC pipe
300 mm dia RCC pipe
Construction brick masonry manhole in cement mortar 1:4 (1cement : 4coarse sand) RCC top slab with 1:2:4 mix 9 with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design.
Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5
Inside size 120 x 90 cm and 90 cm deep including CI cover with frame (heavy duty) 500mm internal dia. Total weight of cover and frame to be not less than 116 Kg. ( weight of cover to be 58 Kg. and weight of frame 58 Kg.)with FPS bricks class designation 75. (Sewerage Line)
Extra for depth for manholes
Size 90 x 80 cm with FPS bricks designation 7.5
Size 120 x 90 cm with FPS bricks designation 7.5
Constructing brick masonary circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement all complete as per standard design.
1.68m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including centering shuttering all complete. Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for seperately).
With F.P.S. bricks class designation 7.5
Extra for depth for circular manholes 1.22m internal dia (at bottom) with beyond 1.68m to 2.29m.
With F.P.S. bricks class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) complete as per design.
Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:5 (1 cement : 5 fine sand) including 500 x 450 mm (heavy duty) precast RCC horizontal grating with frame complete as per standard design: with FPS bricks
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement cincrete 1:2:4 mix (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar 1:3 (1cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete for pipes 100 to 250mm dia.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves,chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing & reinforcement with1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 25mm dia nominal bore
Providing and laying non-pressure NP2 class ( light duty ) R.C.C pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement: 2 fine sand ) including testing of joints etc. complete : a) 450mm dia R.C.C pipe
ALUMINIUM WORK
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, aneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
With stainless steel cover plate minimum 1.25 mmthickness
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately).
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately)
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-incharge
Powder coated minimum thickness 50 micron aluminium
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Upto 5mm depth and 5 mm width
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.
Powder coated minimum thickness 50 micron aluminium
WATER PROOFING
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Water proofing for Old and New Roof Slab:- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with, brush, roller or spray for water proofing coating as per manufacturer specifications with following steps: (a) surface preparation-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt Ltd /MYK Schomberg/Dr Fixit/Fosroc or equivallent Providing and reparing of all comers and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150 mm X 150 mm fillet of mortar (Cement: sand-1:4) admixed with acrylic polymer of Sika Fosroc/MYK Schomberg Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry ofacrylic polymer. Repairing surface irregularities, damaged concrete in base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. (b)1st Coat Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roiler After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg / Samt/coat. For the purpose of measurement the entire treated surface will be measured."
(c) 2nd Coat-To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface 2nd coat should be applied @0.7 kg/Samticoat For the purpose of measurement the entire treated surface will be measured After three days of drying the 2nd coat, the rail water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of EIC. The waterproof coating to be protected from damage before screed over it. Waterproofing Brand- Sika Topseal 109hi/Fosroc Brushbond RFX/Dr Foxit Pidiffin 2K/MYK Aquafin TG Product Performance - Chemical Base Part A Acrylic copolymer, Part B Specially graded cementitious powder- Density 1.6 kg/l (mixed density) at +27°C Tensile Strength -2 Nimm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength -2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370)
(d) Protection of treated surface with PCC-The treated surface should be covered with 25mm/ 50mm PCC of M-20 grade(1:1.5:3) with proper slope (1:120) towards the rain outlets in alternate panels of 2 mt x 2mt keeping 6 mm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 @of 100 ml per bag of of cement to be added in the screed concrete(paid separately for this items) All corners shall be chamfered with 150mm x 150 mm fillet. The rain water outlets shall be just leveled with the screed concrete to ensure smooth discharge of water the peripheral gaps between pvc pipe outlet and concrete surface should be packed property with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika India Pvt. Ltd. /MYK Schomberg/Dr Fixt/Fosroc For the purpose of measurement the entire treated surface will be measured." (e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately). Brand- Sika India Pvt Ltd./MYK Schomberg/Dr Foxit/Fosroc Warranty for five years.
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of :
(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
Using rough kota stone.
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :
Using rough kota stone.
Covering of treated surface with PCC :- Providing 50 mm thick Cement Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F.M 2.5 to 3 including screening,shuttering and mixing cement concrete in mixer with admixture of integral water proofing and placing in position,striking curing,taxexand royality all complete as per building specifiction and direction of Ell.Panels that has been left should be casted next day.There should be 6 mm gap between Panels .Brand-Sika P\astocrate plus, MYK proof WP 1O,Fosroc-Conplast X4211 C,Dr.fixit Pidiproof LW+ or Equivalent .
5.12.8. Providing and filling of 6 mm thickGroove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade)as per drawings and technical specifications and direction of E in Charge.(with 18% GST) .Brand:-Sika-Polysulphide, Fosroc-Thioflex 600,Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivalent
SUB HEAD - STRUCTURAL GLAZING AND ALUMINIUM COMPOSITE PANEL
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately.
The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025.
Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr
Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml.
Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml
Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm
Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site.
Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
CARRIAGE OF MATERIAL
Stone Chipps / stone aggregate (22km )
Coarse Sand ( 10 km)
Brick (8 km) (1 K + 7 P)
Fly Ash Brick (8 km )
Local Sand (10km)
Earth ( 5 km)
TUBEWELL
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 100mm dia
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS:8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete,for all depths, as per direction of engineer -in-charge :
200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of : 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete : 150 mm clamp
150 mm nominal size dia
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part
Providing and fixing brass gate valve with C.I. wheel of approved quality (screwed end)
25 mm dia. Nominal bore
32 mm dia. Nominal bore
40 mm dia. Nominal bore
50 mm dia. Nominal bore
65 mm dia. Nominal bore
80 mm dia. Nominal bore
Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:5 (1 cement : 5 fine sand) for stop cock, with C.I surface box 100 x 100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10graded stone aggregate 40mm nominal size) and inside plastering with cement mortat 1:3 ( 1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design.
With common burnt clay F.P.S. ( Non Modular) bricks of class designation 7.5.
Constructing masonry Chamber 60x60x75cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10graded stone aggregate 40mm nominal size) and inside plastering with cement mortat 1:3 ( 1cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design.
With common burnt clay F.P.S. ( Non Modular) bricks of class designation 7.5.
Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rebber insertions etc. (The tail pieces if required will be paid seperately) :
100 mm dia nominal bore
ELECTRICAL WORKS
POINT WIRING
Point wiring in PVC conduit with modular type switch:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required.
Group A
Group B
Group C
Twin Control Point wiring in PVC conduit with modular type switch:- Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required.
S/F light plug point with modular type accessories:- Supplying & Fixing suitable G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc as required.
S/F power plug point with modular type accessories:- Supplying & Fixing suitable G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch connection, painting etc as required.
S/F 20 amps SPN MCB industrial socket outlet:-Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
S/F Modular type switch/socket:- Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
TV anteena Socket Outlet
Telephone Socket Outlet
6A modular switch
6A modular socket
16A modular switch
16A modular socket
S/F Modular boxes, base & cover plate:- Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mmX75mm)
6 Module (200mmX75mm)
12 Module (135mmX205mm)
S/F Modular type electronic fan regulator:- Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of grade exceeding 1.1KV but not exceeding 11 KV of size not exceeding 400 sq.mm in the existing RCC/ HUME/ STONEWARE/ METAL Pipes as required.
11KV cable laying upto 400 sq.mm. in open duct.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of grade exceeding 1.1KV but not exceeding 11 KV of size not exceeding 400 sq.mm direct in existing masonary open duct as required.
Power plug wiring in PVC conduit (2x4 sq.mm) :- Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Circuit / Submain wiring in PVC conduit :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
2x2.5 sq mm + 1x2.5 sq mm earth wire
4x2.5 sq mm + 2x2.5 sq mm earth wire
2x6 sq mm + 1x6 sq mm earth wire
2x10 sq mm + 1x10 sq mm earth wire
2x16 sq mm + 1x16 sq mm earth wire
4x6 sq mm + 2x6 sq mm earth wire
4x10 sq mm + 2x10 sq mm earth wire
4x16 sq mm + 2x16 sq mm earth wire
S/F S.P. MCB DB :- Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
8 way Double Door
12 way Double Door
16 way Double Door
S/F T.P. MCB DB :- Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plates, interconnections, phosphatized powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
4 Way (4+18), Double Door Horizontal Type
6 Way (4+18), Double Door Horizontal Type
8 Way (4+24), Double Door Horizontal Type
S/F VERTICAL TYPE T.P. MCB DB :- Supplying and fixing following way, three pole and neutral sheet, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable glands plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
12 Way (4+36), Double Door Vertical Type
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following rating 240 volts, C series MCB suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.
6/32 A SP MCB
6/32 A DP MCB
40 A DP MCB
50/63 A DP MCB
6/32 A TPN MCB
40 A TPN MCB
50/63 A TPN MCB
S/F SPN RCCB :- Supplying and fixing of following rating double pole (Single phase & neutral) 240 volts, resudual current circuit breaker (RCCB), having a sensivity current up to 300 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required.
S/F TPN RCCB :- Supplying and fixing of following rating TP&N, (Three phase and neutral), 415 volts, resudual current circuit breaker (RCCB), having a sensivity current up to 300 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required.
Telephone wiring in existing conduit :- Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
TV cable in existing conduit:- Supplying and drawing co-axial TV cable RG-6 grade copper conductor PE insulated, with PVC sheath in the existing surface/ recessed PVC conduit as required.
Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to13:374,.2019 including wiring the down rods of standard length (upto 30cm) with l.Ssq.mm. FR PVC insulated, copper wire suitable for 230V 50H2, single phase supply etc. complete as required.
S/F PVC conduit :- Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20mm dia
50mm dia
S/F Electronic musical call bell :- Supplying and fixing electronic musical call bell suitable for D.C/A.C single phase, 230 volts, complete as required.
S/F Modular type blanking plate:- Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
S/F Batten Holder:- Supplying and fixing brass batten/ angle holder including connection etc. as required.
ITC exhaust fan upto 450 mm sweep:- Installation of exhaust fan upto 450mm in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc as required.
Wiring in existing conduit:- Supplying and drawing following sizes of FRPVC insulated copper conductor single core cable in existing surface/recessed steel / PVC conduit as required.
2 x 1.5 sq.mm
3 x 2.5 sq.mm (For Lift Shaft)
3 x 4.0 sq.mm (For Lift Shaft)
G.I. earth pipe electrode with salt/ charcoal:- Earthing with G.I. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required.
G.I. earth plate electrode:- Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc as required. (with charcoal or coke and salt).
G.I. earth plate electrode (LA):- Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc as required. ( with charcoal or coke and salt).
Copper earth plate electrode:- Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc as required. ( with charcoal or coke and salt).
P/F 25mm x 5mm copper earth strip in surface/ recess :- Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required.
P/F 25mm x 5mm G.I. earth strip in surface/ recess :- Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
P/F 50mm x 5mm G.I. earth strip in surface/ recess :- Providing and fixing 50 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
P/F 6 SWG G.I. loop earthing wire in surface/ recess :- Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
P/F 6 SWG G.I. loop earthing wire conduit/ cable:- Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
P/F G.I. lightning conductor finial:- Providing and fixing lightning conductor finial, made of 25mm dia 300mm long, G.I. tube, having single pronge at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required.
P/F G.I. lightning conductor tape in horizontal run:- Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run).
P/F G.I. lightning conductor tape in vertical run:- Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For Vertical run).
P/F Testing joint for G.I. lightning conductor :- Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
P/F G.I. lightning conductor :- Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottam and 50 cm X 50 cm at the top with a thickness of 10 cm including inscription duly engraved as required.
P/F MV. danger notice plate :- Providing and fixing of MV danger notice plate of 200mm x 150mm made of mild steel, atleast 2mm thick and vitererous enammelled while on both sides and with inscription in single red colour on front side as required.
P/F H.T. danger notice plate :- Providing and fixing of H.T. danger notice plate of 250mm x 200mm made of mild steel, atleast 2mm thick and vitererous enammelled while on both sides and with inscription in single red colour on front side as required.
11KV cable laying upto 400 sq.mm. in pipes.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of grade exceeding 1.1KV but not exceeding 11 KV of size not exceeding 400 sq.mm in the existing RCC/ HUME/ STONEWARE/ METAL Pipes as required.
S.I.T.C of floowing rating surface mounted LED tube light fitting suitable for 230V 50H2, single phase supply etc. complete as required.
20122W LED Tube light
11KV cable laying upto 400 sq.mm. in open duct.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of grade exceeding 1.1KV but not exceeding 11 KV of size not exceeding 400 sq.mm direct in existing masonary open duct as required.
S.I.T.C of floowing rating reccess/surface mounted LED round/square shape Down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirm to IS:10322 part-5/section-2 or IEC:62722with all neccssary acc$sories as required
6/7W LED Round Down light
l2W LED Round Down ligbt
15/16W LED Square Down light
l8/20W LED Square Down light
Supply, Installation, Testing & Commissioning of 1x20 watt LED Light recess mounted downlight with high efficiency electronic driver. (Make Philips Cat No RC380B LED36S-6500 G4 L60W60 PSU or equivalent.)
Supply, Installation, Testing & Commissioning of 1x10 watt LED Mirror light fixture wall mounted with electronic high efficiency electronic driver as complete as required. (Philips Make, Cat No- BN021 LED 10S or equivalent).
Supply, Installation, Testing & Commissioning of Bulk Head Light Fixture surface mounted Philips make cat no- WT140 or equivalent.
CCTV SYSTEM (CONDUITING & WIRING ONLY)
TV cable in existing conduit:- Supplying and drawing co-axial TV cable RG-6 grade copper conductor PE insulated, with PVC sheath in the existing surface/ recessed PVC conduit as required.
Supply of following sizes of 1.1KV grade multicore Copper / aluminium conductor XLPE insulated and PVC sheathed armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant).
3.5 core, 25 sq.mm aluminium armoured cable
3.5 core, 35 sq.mm aluminium armoured cable
3.5 core, 50 sq.mm aluminium armoured cable
3.5 core, 70 sq.mm aluminium armoured cable
3.5 core, 95 sq.mm aluminium armoured cable
3.5 core, 120 sq.mm aluminium armoured cable
3.5 core, 150 sq.mm aluminium armoured cable
3.5 core, 185 sq.mm aluminium armoured cable
3.5 core, 240 sq.mm aluminium armoured cable
3.5 core, 300 sq.mm aluminium armoured cable
4 core, 10 sq.mm.
2 core, 10 sq.mm.
2 core, 6 sq.mm.
3.5 core 400 sq. mm
4 core 16 sq.mm
4 core 6 sq.mm
DIESEL GENERATING SET:
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Storing, Installation, Testing and Commissioning of Radiator Cooled DG sets of following capacity (rating in kVA) compact packaged silent type, with Outdoor type Acoustic Enclosure to reduce the noise level as per requirements of central pollution control board, 415Volts, 3 phase, 50 Hz AC alternator coupled to diesel engine with mechanical governor complete with all accessories, standard specifications tool kits, service manual, self starting device, fly wheel, coupling with guard, V velt, radiator, instrument panel (starting switch with key, Water Temperature indicator gauge, Lub OIl Pressure gauge, Lube oil temperature gauge, Battery Charging Ammeter, indicating lamp, hour counter etc.), residential silencer with insulation & aluminium cladding, common bed plate, anti vibration isolation pads, extended cable termination box, grouting bolts, first charge of engine oil, gear oil, high speed diesel oil, 12 volt maintenance free chargeable battery set with Trickle/Boost Battery charger, interface card for BMS connectivity complete as required of rating 415 Volts, 3 phase, 50 Hz. AC alternator coupled to Diesel Engine complete with all accessories. NOC from concerned goverment authority for installation and operation of D.G. set shall be taken by contractor. D.G. Set shall be as per CPCB-II.
500 KVA D.G. Set with suitable capacity of day oil fuel Tank
Supply, installation, testing & commissioing of 15 KVA UPS in paralleling mode at 0.9 input power factor with inbilt isolation transformer as per specification given in the document with following broad features.
THD(i) shall be less than 5% in the entire loading range.
UPS shall carry design output at 40 deg.
Shall have soft start and hold of for incoming supply.
Invertor capability to supply 150% load for 5 sec.
Three Phase Input and Three Phase Output. (Input - 340V - 470V, Three Phase, 4 wire. / Output - 400-415 Volt, Three Phase, 4 Wire.)
Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.
Battery shall be external type with rack and suitable for 15 minute backup on 100% load.
UPS shall be compatible for parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS.
UPS described as above
Fixing louvers shutters for exhaust fan:- Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and fixing of following sizes of STEEL conduit alonwith the accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
20mm dia
25mm dia
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm wide x 50 mm depth x 2.0 mm thickness.
750 mm wide x 62.5 mm depth x 2.0 mm thickness.
900 mm wide x 62.5 mm depth x 2.0 mm thickness.
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm wide x 50 mm depth x 2.0 mm thickness.
750 mm wide x 62.5 mm depth x 2.0 mm thickness.
900 mm wide x 62.5 mm depth x 2.0 mm thickness.
Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm wide x 50 mm depth x 2.0 mm thickness.
750 mm wide x 62.5 mm depth x 2.0 mm thickness.
900 mm wide x 62.5 mm depth x 2.0 mm thickness.
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee’s with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm wide x 50 mm depth x 2.0 mm thickness.
750 mm wide x 62.5 mm depth x 2.0 mm thickness.
900 mm wide x 62.5 mm depth x 2.0 mm thickness.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design:
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg).
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.
150 mm dia. R.C.C. pipe
250 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
Supply,Installation,Testingand Commissioning of on grid Solar Photo voltaic Power Plant conforming to MNRE specification sasam ended,consisting of Mono/Poly Cry stallinesilic on solarcells,net metering facility,necessary protections,earthing,mounted on Aluminium / GI structure of suitabl estrength with following components complete as required:-a) Solar Photo voltaic Module of capacity 330 Wp or above,manufactur edin India,conforming to IS14286 / IEC61215,IS/IEC61730-Part-1,IS/IEC61730-Part-2.Solar Photo voltaic Module conversion efficiency shall not beless than16.5%.PV module susedin solar power plants / system smustbe warranted for the irout put peak watt capacity,which should not beless tha Supply, Installation ,Testing and Commissioning of on grid Solar Photo voltaic Power Plant conforming to MNRE specification salamander, consisting of Mono/Polycrystalline silicon solar cells , net me teringfa cility, necessary protections, earthing,mountedon Aluminium/ GI structure of suitable strength with following components complete as required:-a)Solar Photo voltaic Module of capacity 330 Wp or above, manufactured in India,conforming to IS14286/IEC61215,IS/IEC61730-Part-1,IS/IEC61730-Part-2.Solar Photo voltaic Module con version efficiency shall not beless than16.5%.PV module sussed in solar power plants / system smustbe warranted for their out put peak watt capacity, which should not be less than 90 % at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU)of350-800VDC Input voltage range and 400 VAC,three phase,4 wire,50Hz+/-2.5Hz,out put voltage suitable to generate ACP ower with efficiency not less than 97%,tota harmonic distortion less than3%and suitable for ambient temperature from 0 to 50 degreeC.ThePCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency’s) Data Monitoring System complete with accessorised) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands ,lugs and other accessories etc. as required) Lightning and surge voltage protection.f) Connections & Inter connectionsby supplying & fixing required size XLPE insulated copper conductor1.1kV grade armoured powerand control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel / conduit lug sand other accessories etc. as requiredn 90% attheend of10 years and 80%attheend of 25 years.b)PowerConditioningUnit(PCU)of350-800VDC Input voltage rangeand 400VAC,threephase,4wire,50Hz+/-2.5Hz,out put voltage suitable to generate AC Power with efficiency not lesst han 97%,to talharmonicdistortion less than 3%and suitable for ambien temperature from0to 50 degreeC.ThePCU shall adjustthe voltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box withI P65 protection and termination arrangeme ntforinc oming and out going cable along withglands,lugsand other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Inter connections by supplying & fixing required size XLPE insulated copper conductor1.1kV grade armoured power and control cables between solar modules,main power cable to grid supply PCU unit along with supplying & fixing of necessary channel / conduitlugs and other accessories etc.as required
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required.
3.5 X 25 sq. mm (28mm) For aluminium armoured cable
3.5 X 35 sq.mm (32 mm) For aluminium armoured cable
3.5 X 50 sq.mm (35 mm) For aluminium armoured cable
3½ X 95 sq. mm (45mm) For aluminium armoured cable
3½ X 120 sq. mm (45mm) For aluminium armoured cable
3.5 X 150 sq.mm (50 mm) For aluminium armoured cable
3½ X 185 sq. mm (57mm) For aluminium armoured cable
3½ X 240 sq. mm (63mm) For aluminium armoured cable
3½ X 300 sq. mm (70mm) For aluminium armoured cable
3½ X 70 sq. mm (38mm) For aluminium armoured cable
4 X 10 sq. mm (25mm)
2 X 10 sq. mm (19mm)
2 X 6 sq. mm (19mm)
4 X 25 sq. mm (28mm)
4 X 16 sq. mm (28mm)
3½ X 400 sq. mm (82mm)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
CIRCUIT / SUBMAIN WIRING
2x1.5 sq mm + 1x1.5 sq mm earth wire
2x2.5 sq mm + 1x2.5 sq mm earth wire
4x2.5 sq mm + 2x2.5 sq mm earth wire
2x6 sq mm + 1x6 sq mm earth wire.
2x10 sq mm + 1x6 sq mm earth wire.
4x6 sq mm + 2x6 sq mm earth wire.
4x10 sq mm + 2x6 sq mm earth wire.
4x16 sq mm + 2x6 sq mm earth wire.
2x16 sq mm + 1x6 sq mm earth wire.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required.
Wiring for fire alarm system with following PVC insulated copper conductor 1100 volts grade stranded "FRLS" wires in existing conduits.
2 x 1.5 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary duct as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
11 KV END TERMINATION:
Supply & making of INDOOR cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core XLPE aluminium conductor cable of 33 KV grade as required.
3C x 240 Sqmm, 33KV XLPE
Supply & making of OUTDOOR cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core XLPE aluminium conductor cable of 33 KV grade as required.
3C x 240 Sqmm, 33KV XLPE
HT CABLE LAYING:
Laying of one number XLPE power cable of 33 KV grade of following size in the existing masonry open duct as required.
Above 120 sq. mm and upto 400 sq. mm
Laying of one number XLPE power cable of 33 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Above 120 sq. mm and upto 400 sq. mm
Laying of one number additional XLPE power cable of 33 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Above 120 sq. mm and upto 400 sq. mm
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying,including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.
RISING MAIN-
Supplying, Installing on wall, testing and commissioning of following capacity Air Insulated Compact Type Rising Mains for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every meter, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.
HVAC WORKS
Double Skin AHU (CC + Pre Filter)
Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 6 row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.) and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities.
Pressure Independant Balancing Cum Two Way Control Valve on Cooling Coil
Supply, installation, testing and commissioning of modulating type two-way pressure independent dynamic control & balancing valve with spring return feature. The valve shall be suitable for chilled/hot water duty and installed at each air handling unit. The minimum close off pressure actuator must be 1.5 times shut off head of pump or 5 bars whichever is maximum. The operation of valve shall be through Building Automation System and hence capable of recieving 0-10V or 4-20 mA signal from remote controllers. The valve shall be suited for installation on following pipe sizes. Price shall include the cost of Insulation, material and external treatment will be same as of pipe :
Note- The manufacturer shall guarantee the free replacement of 5 years for any defects found during operations.
19 mm Dia, Maximum 5 GPM
25 mm Dia, Maximum 9 GPM
32 mm Dia, Maximum 15 GPM
40 mm Dia, Maximum 26 GPM
50 mm Dia, Maximum 54 GPM
65 mm Dia, Maximum 80 GPM
80 mm Dia, Maximum 125 GPM
Chilled / Hot Water Piping With Factory Laminated Glass Cloth Nitrile Rubber Insulation
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density (Factory Laminated Glass Cloth Nitrile Rubber Insulation), thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect.
Note:-The Pipes of sizes 150 mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
250 mm dia. (32 mm thick insulation)
200 mm dia. (32 mm thick insulation)
150 mm dia. (32 mm thick insulation)
125 mm dia. (32 mm thick insulation)
100 mm dia. (32 mm thick insulation)
80 mm dia. (32 mm thick insulation)
65 mm dia. (32 mm thick insulation)
50 mm dia. (32 mm thick insulation)
40 mm dia. (32 mm thick insulation)
32 mm dia. (19 mm thick insulation)
25 mm dia. (19 mm thick insulation)
Motorised Butterfly Valves
Supply, installation, testing and commissioning of motorised on / off butterfly valves with modulating motor in return chilled & hot water line of each chiller & Hot Water Generator operated through BMS & of following sizes. Valves shall be insulated as per pipe insulation material & thickness given above.
200 mm dia (For Chiller)
100 mm dia (For Hot Water Generator)
Manual Balancing Valves
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.
200 mm dia (For Chiller)
100 mm dia (For Hot Water Generator)
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot eater circulation as specified
200 mm dia
150 mm dia
125 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.
200 mm dia
Y-strainer ( With Insulation )
200 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
Pressure Gauges
Supply, installation, testing and commissioning of pressure guage of approved make of dia 150 mm conforming to tender specifications.
Thermometer
Providing & fixing in position the mercury in glass industrial type thermometers.
Condenser Water Piping
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends, tees etc..but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect.
Note:-The Pipes size 150 mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
150 mm dia pipe
250 mm dia pipe
300 mm dia pipe
Motorised Butterfly Valves
Supplying, fixing, testing and commissioning of following sizes Motorized Butterfly Valve with CI Body, SS Disc, O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20 mA electric signal and providing similar transduced feedback output to control system as required.
250 mm dia (For Condenser Out, Cooling Tower In & Out)
BUTTERFLY VALVE (MANUAL) with CI body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified.
50 mm dia
Thermometer
Providing & fixing in position the mercury in glass industrial type thermometers.
Pressure Gauges
Supply, installation, testing and commissioning of pressure guage of approved make of dia 150 mm conforming to tender specifications.
Rectangular GI Ducting
Rectangular GI Ducting (Factory Made - L Shape)
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
24 G (Up To 750 mm)
22 G (751 to 1500 mm)
20 G (1501 to 2250 mm)
18 G (Above 2250 mm)
Site Fabricated GI Ducting
Supply, installation, balancing and commissioning of site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required
a) 24 G (Up To 750 mm)
b) 22 G (751 to 1500 mm)
c) 20 G (1501 to 2250 mm)
d) 18 G (Above 2250 mm)
Duct Accoustic Lining
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
Fire Dampers & Actuator
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
Fire Damper
Actuator
Grilles, Diffusers, VCD
Supply, installtion and testing of Powder coated Aluminium extruded grills / diffusers as per specifications given in tender and of following sizes.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
GSS Duct Damper
Supply, installation and testing of multiblade box type Galvanized Sheet Steel construction damper for ducts to be provided with suitable links and quadrants for control of volume of air.
Acoustic Insulation of AC Plant Room / AHU Room
Supplying, fixing acoustic lining on wall and ceiling of AC Plant Room with 50 mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610 mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.
FIRE FIGHTING WORKS
FIRE PUMPS & HYDRANT WORKS
FIRE PUMPS - ELECTRICAL
Providing, Installation, testing & commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, grade 304, sheet with 3 mm dia holes with stainless steel flange.
250 mm dia
(A) Supplying, Installation, testing & commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respescts, as required: (Teearce Pump)
(B) Horizotal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS:1520
(C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase , 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with class-'F' insulation, confirming to IS-325
(D) M.S fabricated common base plate, coupling, coupling guard, fouldation bolts etc. as required.
(E) Suitable cement concrete foundation duly plastered and with anti vibration pads
450 LPM at 35M Head
900 LPM at 35M Head
Supplyin and fixing air vessel made of 250 mm dia, 8 mm thivk M.S sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure guage and painting with synthetic enamel point of approved shade as required:
Providing & fixing of pressure switch in M.S line including connection etc. as required.
Supplying and fixing single headed internal hydrant valve with instantaneous gunmetal/stainless steel coupling of 63 mm dia with cast iron wheel ISI marked confirming to IS 5290 (Type- A) with blank gummetal/stainless steel cap and chain as required:
Single headedd stainless steel
Supplying and fixing single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM gun meatl/Stainless steel coupling and cast iron wheel, ISI marked, comnfirming to IS 5290 (type-A) with blank gunmeatl/stainless steel cap and chain as required:
Single headedd stainless steel
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required:
Stainless steel (Grade 304)
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female coupling duly bound with GI wire, rivets etc. cionfirming to IS 636 (type- A) as required:
Stainless steel (Grade 340)
Supplying and fixxing first-aid hose reel with MS construction spray painted in post office red, confirming to IS 884 complete with the following as required
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type- 2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipments on wall.
Connections from riser with 25 mm dia stop gum metal valve & M.S. pipe and socket.
Supplying & fixing orifice plate made out of 6 mm thich stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external & internal hydrants to reduce pressure at the outlet to the level of 3.5 Kg/Sqcm complete as required.
Supplying & fixing of the fire brigade connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as required for suitable dia MS pipe connection confirming to IS 904 as required.
4 way - 150 mm dia M.S. pipe
2 way - 150 mm dia M.S. pipe
PIPING & VALVES FOR FIRE FIGHTING SYSTEM
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms,depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth,including consolidating each deposited layer by ramming, watering,etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m:
Ordinary rock
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Hard Rock
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Making 1:2:4 cement concrete supports and thrust blocks generally as per required and approved.
Constructing masonary chamber 90 x90 x100 cm. inside with 75 class designation brickwork in cement mortar 1:4 ( 1 cement : 4 fine sand) for sluice valve with CI surface box 100 mm top dia. 160 mm bottom dia. And 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1 :5 :10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size and inside plastering with 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design with FPS bricks
Providing, Laying, testing & commissionong of 'C' class heavy duty MS pipe confirming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coatar/asphalt taps as per IS 10221, refilling the trench etc. of following sizes complete as required.
150 mm dia
Supplying & fixing, testing & commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of follwong sizes as required:
80 mm dia
100 mm dia
150 mm dia
200 mm dia
Providing, Installation, testing & commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required:
200 mm dia
150 mm dia
80 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe confriming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges. Tappers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamal paint of required shade complete as required:
250 mm dia (wall thickness 6.3 mm)
200 mm dia (wall thickness 6.3 mm)
150 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
SPRINKLERS SYSTEM
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Pendent Sprinkler
Horizontal side wall sprinkler
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe confriming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges. Tappers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamal paint of required shade complete as required:
150 dia MS pipe
100 dia MS pipe
80 dia MS pipe
65 dia MS pipe
50 dia MS pipe
40 dia MS pipe
32 dia MS pipe
25 dia MS pipe
ELECTRICAL WORKS
Earthing Strip / Wires.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
SCHEDULE ITEM (A)
Providing and laying light weight Foam Concrete of density 500 kg/cum in sunken portion at all levels as per direction of Engineer-In-Charge.
Providing and fixing of fully insulated Wooden fire rated doors as per BS:476 Part-20 & 22 & IS 3614 part-2 for stability, integrity and thermal insulation 03 Criteria Wooden door . Fire door shall be tested at CBRI, Roorkee for maximum rating of 2 hrs. Any deviation in specification other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door leaf shall be minimum 50mm thick fully flush door, 50 mm thick shutter, comprising of 75mm x 44mm hardwood internal timber frame work, with infill of 96 kg / m3, ceramic fiber blankets, coated with VIPER FR intumescent coating on both sides for insulation . The coated intumescent coating on both sides for insulation. The coated insulation shall be sandwiched between minimum 12 mm thick PAMTECH/ROMATECH or equivalent make calcium silicate Boards on both sides (edge to edge or internal Hardwood frame) having a maximum density of 700 kgs/Cum, Cladded with 3mm Commercial Ply & 1 mm thick laminate (as per approved shade) on both sides of the shutter with 50mm x 14mm teak wood lipping all-round the shutter. The door frame will be made out of Hardwood (Red Mirandi) of maximum section 120 x 70mm and coated with VIPER or approved Fire reatrdent Primer. The rebate shall be of 20 mm x 53mm in the Door Frame to accommodate the shutter in frame. Both frame and shutter shall be fitted with 2 Nos of fire & smoke intumescent seal of approved make of size 10 x 4 mm on all the three sides of the Frame and 1 No. 20 mm x 4mm Fire Seal on Shutter except bottom. The pasting of the ply/laminate should be done using automatic machine and should be free from any nails or perforations. The door supplier should have tested their door within last 5 years at CBRI, Roorkee. all complete as per direction of Engineer-incharge
Providing & Fixing following fire rated fittings as per manufactures specifications and direction of the Engineer-In-Charge.
Door Locks
Glass ( Wired) Vision Panel Of Size 200mm X 300mm
Door closer
SS Door Handles
SS Tower Bolts
Panic bar for S/L door
External trim for panic bars
2000 Series Windows – Double Rebate Windows Providing & fixing of windows made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 48 x 25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy duty stain less steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10mm square guard bars with 6” (152.4mm) pitch, complete for finished item of work including of all taxes. (Make: A2Z Infra Solutions/ Elixir Metform Pvt Ltd./ Lakshmi Fabrications)
Granite work gang saw cut (polished and machine cut) of thickness 18mm for wall lining,skirting and dado (veneer work) in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade: (To be secured to the backing by means of cramps, which shall be paid for separately).
Providing & Fixing of 8mm thick Rubber flooring Rolls with 15% EPDM & 85% SBR, Density (kg/m3):1000/1200, Hardness (Shore a):68, Stretch (MPA):2.2, Abrasion resistance: 0.0075g (ASTM‐D4060‐01), Rebound resistance: 55%, Friction coefficient: trends μs: 0.995 .trends μk: 0.930, Shape deformation: 42%, Length (m):10 ±5cm, Width (m):1m ±5mm, Thickness (mm): 8mm ±0.3mm etc.complete as per the direction of Engineer-in-charge.
Providing and applying special pure acrylic base resin stone texture paint ( finish thickness 1.2mm to 1.5 mm) Marmoplast of Ultratech make or equivalent . One coat of acrylic Primer Mixed with wall sealer in the ratio of 1:1 is applied with brush and roller. Repairs to be done with interior grade putty post primer application . One Coat of stone crushed texture to be applied as pitted finish applied with special tool (added with inorganic pigments from 0.01- 3.00%) after the final texture coat one coat of pure acrylic emulsion followed by final coat of siloxane base protection coat to be applied which make the product completely water repellent / dust resistant / antifungal which ensures with a warranty of 08 years on shades and sustainability ,whereas grooves are to be crafted in plaster as design approved by engineering in charge.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing S.S. 304 tower bolts ( 300 X10 mm Article Code no 911.81.585 Of Hafele or equivalent) with necessary SS screws etc.complete.
Providing and fixing S.S. 304 tower bolts (150 X10 mm Article Code no 911.81.576 Of Hafele make or equivalent) with necessary SS screws etc.complete.
Providing and fixing S.S. 304 D Type pull Handle 300 X22 mm ( Article Code no 903.11.470 of Hafele make or equivalent) with necessary screws etc. complete .
D Type pull Handle 300 X22 mm
Providing and fixing Double Rod hanging floor door stopper ( Article Code no 938.66.000 Hafele or equivalent ) of brass metal in SS Finish with necessary screws etc. complete.
Providing and fixing stainless steel Hydraulic door closer ( Article Code499.30.002 of Hafele or equivalent) , door weight up 80 kg with necessary accessories and screws etc. complete.
Providing and fixing S.S. 304 sliding door bolts ( 300 mm Product Code no 4033 of Godrej & Boyce Mfg make or equivalent ) with nuts and screws etc. complete : 300x16 mm
Providing and fixing S.S. 304 sliding door bolts ( 250 mm Product Code no 4032 of Godrej & Boyce Mfg make or equivalent ) with nuts and screws etc. complete : 250x16 mm
Add for extra 2 nos grooves in granite treads size of 5mm X 10mm as per direction of Engineer in Charge.
Supply and installation of PVC flooring of 1.83m wide, having a nominal total thickness of 2.2mm. The nominal thickness of the wear layer would be 2 mm. The product should have a conductive backing of 0.2mm. The wear surface shall consist of impregnated polyurethane homogeneous mixture of PVC, Plasticizers, Urethane, color pigments and filler calendared to form a sheet. Colors and pattern detail shall be dispersed throughout the thickness of the wear layer. It shall conform to Group P of Wear Resistance as per EN 649, Flammability of class Bfl-s1 as per EN 13501-1, Slip resistance of R9 as per BGR 181, Dynamic Coefficient of friction as DS as per EN 13893, Impact sound reduction of 3 dB as per EN ISO 140-8, Residual indentation of 0.05 mm as per EN 433, Color fastness rating ≥6 as per ISO 105-B02, Vertical resistance(R1) less than 106Ω as per EN 1081, Static electrical charge of ≤2.0kV as per EN 1815, Thermal resistance of 0.01m²K/W as per EN 12667, Thermal conductivity of 0.25 W/mK as per EN 12524. PASTELL conductive shall exhibit ESD properties as following - Vertical resistance less than 3.5x10^6Ω as per EN 61340-4-1, Static electrical charge - system test less than 100V as per EN 61340-4-5.The class of use of is 23/34/43 as per EN 685.
Installation: It is important to ensure the sub floor on which the sheet is being laid is smooth, flat & hard & free from moisture,grease, etc. In case of uneven sub floor the same should be leveled by self leveling compound. IPS/Vitrified/ceramic/mosaic tiles do not provide zero leveled sub floor.The moisture level present in the subfloor should be less than 8% before installation of the floor. The sheet should be laid using adhesive recommended by Armstrong. Each row of tiles/strip of floor covering must be linked crosswise with a continuous copper strip. Individual rows/strips must be at least 3 m² in size and linked to the rest of the area with a copper tape. In rooms of up to 40 m², connection points for equipotential bonding should be provided in at least one point in the room. In larger rooms, several connection points must be used. The installation shall be undertaken as per the manufacturer’s installation instructions
Supply and installation of PVC Sheet wall covering manufactured by Armstrong World Industries, Inc, 1.5m wide, having a nominal total thickness of 1mm. The nominal thickness of the wear layer would be 1.25mm. The wear surface shall consist of impregnated polyurethane homogeneous mixture of PVC, Plasticizers, Urethane, color pigments and filler calendared to form a sheet. Colors shall be dispersed throughout the thickness of the wear layer. Wallflex shall conform to Group M of Wear Resistance as per EN 660-2, Fire resistance of group 2 as per AS/NZS3837, Residual indentation of ≤0.10mm as per EN433, curling after exposure to moisture ≤8mm as per EN434, Seam strength of mean≥240N/50mm as per EN684.
Providing of 2 - 3 mm average thick layer of cementations smoothening compound of UZIN NC 149 sh or equivalent as recommended by the Vinyl sheet flooring manufacturer over and including a priming compound of UZIN PE 360 sh or equivalent as recommended by the Vinyl sheet flooring manufacturer and installation team on concrete surface to provide a smooth & homogenous surface for laying of vinyl sheet flooring complete to the entire satisfaction of Engineer-in-charge
Providing and fixing 230mm X 75mm X 15mm size of Clay tiles work for wall lining with special adhesive like Araldite or equivalent over 10mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade.
Providing and fixing 230mm X 75mm X 15mm size of Clay tiles work for wall lining with special adhesive like Araldite or equivalent over 10mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade.
SUPPLY AND FIXING OF 4MM THICKNESS POLYCARBONATE SOLID SHEETS WITH BOTH SIDE 50 MICRONS UV CO-EXTRUSION IN 4MM THICKNESS OR ABOVE, COLOUR AS APPROVED. THE COMPACT SHEETS SHALL BE 1220MM WIDE & LENGTH NOT MORE THEN 3050MM /4000MM/ 15250MM/ 33500MMAND IS TO BE FIXED WITH ALUMINIUM PRESSURE PLATES WITH EPDM RUBBER TO ENSURE WATER TIGHTNESS AND MAXIMUM UPLIFT CAPABILITY. THE WEIGHT SHALL NOT BE LESS THAN 4.80 KGS PER SQ.MTR. THE COMPACT SHEETS SHOULD BE PLAIN ON BOTH SIDES AND MANUFACTURED FROM PRIME GRADE PC RESINS. MANUFACTURER TEST CERTIFICATE SHALL BE PROVIDED FOR SUPPLIES MADE.” Complete as per direction of Engineer-In-Charge.
Providing and fixing 230mm X 75mm X 15mm size of Clay tiles work for wall lining with special adhesive like Araldite or equivalent over 10mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade.
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately) Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Providing and fixing unperforated corrosion resistant Aluminium Magnesium alloy lineal metal panel ceiling system by Hunter Douglas/Armstrong/ Saint Gobain or Equivalent of approved wood Finish colour consisting of panel 180mm wide x 15mm deep x 0.6mm thick with square edges, panel length up to 6 mtrs, Coil Coated on a Continuous Paint Line, Double baked and roll formed from doubled baked enameled corrosion resistance aluminium magnesium alloy for higher strength and good roll forming characteristics. Panel shall be clipped to a baked enameled aluminium panel carrier of 62mm wide x 29mm deep made of 0.90 mm thick in standard length of 5 mtrs made of doubled enameled aluminium magnesium alloy black with cut outs to hold the panels in a module of 200 mm and at a distance 1.45 mtrs without insulation. The carrier shall be suspended by means of G.I suspension rod 4mm diameter and a Galvanized suspension spring clip at a distance of 1.7mtrs centre to centre.All complete as per drawings, specification and direction of the Engineer in Charge. All Ceiling products shall adhere to Green Pro Certification Paint finish: Aluminium panels shall be chromatised for maximum bond between metal and paint enamelled twice under high temperature, one side with full primer and finish coat, the other side (inner side) with a primer coating and skin coat on a Continuous Paint Line. Mode of Measurements: Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. Wood finish
Flotex Carpet (Area- Conference , Auditorium) Providing & Fixing of Flocked textile floor covering of Nylon 6.6 face fiber or equivalent of approved make with 100% Nylon and completely water proof resilient backing. The flooring should be Anti static with thickness of 4.3 mm and approximate weight of 1.8 k.g./sqm of roll form. The carpet should be completely stain resistant and of a density approx. 80 million fibers/sq.mtr (70 million fiber/sq.yd) in the width of 2 mtr .The floor covering should have Fire Test EN-13501, Appearance Retention Hexapod ISO 140-8, Friction Slip Resistance Test EN 14041 Class DS, SANITISED anti-microbial treatment, with resilient waterproof backing, anti allergic which is certified by British allergy foundation, with ten year replacement guarantee. The carpet should have permanent static control & should be fixed with powder coated aluminum angles as per detail. Aluminum angles to be paid separately. The work should be carried out by the authorized installer of the Company in India.
Providing & Fixing 3 mr Automatic Boom Barrier with Wireless Remote Control as per manufacurere specifications and direction of engineer-in-charge.
Providing , Fixing, testing and commissioning of CP Brass 115mm long Shower Arm with wall flange and pressure adjustable Shower Rose complete with all accessories as required and making good the walls wherever required. (MAKE-CERA -Model No-F7040101 FOR SHOWER ARM & CERA MAKE FOR HEAD SHOWER F7020301 or EQUIVALENT.)
Providing and fixing 8mm thick beveled edge glass mirror with side polished complete including fixing over marine plywood frame work with silicon at all levels & height including fixing of molded ,screw and silicon etc. incl labors, tools, scaffolding at all heights as per Direction of EIC .
Providibng and fixing straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector.
Providing and fixing CP brass single lever low flow wall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete including cutting and making good the walls where required.(1) Kerovit make (Model -KB211024-CP). (2)Hindware Make(Model-F230014) Rs.=5640. (3) Parryware Make(Model-T1635A1)Rs.=6800
Providing & Fixing of Grab Bar size 300mm long in handicap toilet complete as required.Makes & Model No.Jaquar AKP-35701P.
Providing & fixing glass urinal partition of Height: 900mm,Width: 450mm &Frosted Safety Glass: 8 mm with fixed with expandable anchor fasteners with C.P. brass bolts and washers, embedded in wall with anchor and set in cement concrete complete including cutting and making good the walls wherever required .(1) (MAKE-JAGUAR: MODEL NO-Model No. 1810-US, 1810-UC.)(2)Hindware Make(Model-61001) Rs.=3500.
Providing,Fixing satin finish stainless steel AISI 316 grade wall mounted coat hook on door complete. Jaquar make CAT No- AKP-35791P (2)Hindware Make(Model-Robe Hook F870007) Rs.=1216.
Providing & fixing brass ball valve with hard chrome plated ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete:in all respects.
15 mm dia
100 mm dia, nominal bore
Fixing of Storage type water heater/ Geyser with required accessories like 15 mm CP angle valve on inlet , heavy duty reinforced flexible PVC connector for cold water line and flexible CP brass connector with CP checkout for hot water line, CPVC line connection, MS bracket with two coats of enamel paint, anchor fastners etc to hang the units, providing and fixing of 16 A 3 Pin plug of Anchor make, etc complete as required.
Capacity 25 Liters
Providing and fixing sound insulated Polyproplene piping system as per ON EN 1451-Part 1-6 & EN 12056 Part 1-5 with 3 layer pipe made of PP-C + PP-MV + PP-C in Blue Ral 5014 (halogen and calcium free) colour, push-fit type, food safe, having high impact and stiffness, offering sound levels of not more than 22 dBA as per DIN 4109 at a flow rate of 4 l/s and having pipe ring stiffness as per 1S0/DIS 9969 and tightness as per EN 1277/B and C and DIN 19560, density of pipe = 1.25gms/cm3, elongation = 0.05mm/m0K and tensile strength > 24 N/mm2,with all necessary fittings in blue colour, fitted with factory fitted lip ring incluiding painting with ordinary cement based paint for external installation.
Providing and fixing sound insulated Polyproplene piping system with 3 layer pipe fittings, push-fit type, food safe, having high impact and stiffness, offering sound levels of not more than 22 dBA ,with all necessary fittings , fitted with factory fitted lip ring incluiding painting with ordinary cement based paint for external installation. (POLOPLAST - PKNG, RAUPIANO PLUS).
Tee 90degree 110 mm dia.
Tee 45degree 110 mm dia.
Providing and fixing terminal guard 100mm standard PP
Providing and fixing terminal guard 100mm standard PP
Providing and fixing PP white Trap with minimum 50mm water seal with rubber seal on inlet to push fit hopper for indirect waste connections (McAlpine, UK) or equivalent.
110 mm inlet & 110 mm outlet.
Providing and fixing sound insulated Polyproplene piping system with 3 layer pipe, push-fit type, food safe, having high impact and stiffness, offering sound levels of not more than 22 dBA with all necessary fittings, fitted with factory fitted lip ring.(POLOPLAST - PKNG), RAUPIANO PLUS , HULIOT or equivalent).
160 mm bend
160 mm Shoe
Providing and fixing G.I. Inlet fitting of suitable size with 2 & 3 Nos. G.I. Socket 32 & 40 welded G.I. pipe and dipped in hot bitumen complete in all respect.
100 mm diameter pipe (Hopper)
Providing and fixing floor drain made of 100 x 50 dia elbow / tee as applicable connected with 50 dia GI pipe painted with primer, two coats of black bituminastic paint,wrapping 1 mm thick PVC tape and final coat of black bituminastic paint B109 complete in all complete including cutting and making good the walls and floor wherever required
Providing and fixing flanged cleanout plug with M.S. flanged tail pieces, blind flang, 6mm dia nut & bolts, gasket and washers fixed to C.I. Pipe with drip seal joint complete in all complete including cutting and making good the walls and floor wherever required
with 100 mm dia. Pipe
Providing & fixing of epoxy coated 25 mm thick C.I. Grating with frame for channel drains including all accessoreis complete
WATER SUPPLY INSTALLATIONS
Providing stainless steel pipes conforming to EN 10312 standard complete with press type fittings for Hot and cold water supply, RO & domestic water supply system capable to withstand temperature upto 1100 centigrade and pressure upto 16 bars made from 316 L grade-Material no. 1.4404 (X2CrNiMo17-12-2) of annealed and pickled stainless steel sheet, with ends deburred at 900 and with length of 3 meters. Pipe qualifying to 100% eddy current, 100% hydrostatic tested and air-under water tested under 10kgs. Fittings also conforming to EN 10312 standard in 316 L stainless steel grade of approved make in accordance with DVGW regulation such as tees, coupling, elbow, male adapter, connectors etc with Black grooved O-ring of EPDM material which can withstand temperature upto -200 to 1100 C including suitable connection as per site requirement. Direct contact of stainless steel pipes and fittings to galvanized iron should be avoided by inserting approved type of filler material as per project manager’s/consultant requirement. Flanges, clamps with hanger at a spacing of 2 m centre to centre min or as required etc. necessary adapters for GI/copper and CP fittings, jointing, sundries, cutting holes in walls/floors/slabs & making good complete. (JINDAL,VEIGA,ALFA)
18 mm dia, nominal bore
22 mm dia, nominal bore
28 mm dia, nominal bore
35 mm dia, nominal bore
42 mm dia, nominal bore
54 mm dia, nominal bore
76 mm dia, nominal bore
89 mm dia, nominal bore
108 mm dia, nominal bore
40mm nominal outer dia. Pipes.
Cost of drilling 200mm x150mm x230 meter deep bore well in all kind of soil and rock in rural or any other area for installation of pump sets with hydraulic DTH Rig machine all complete including supplying all materials tools drilling rig and air compressor and equipments, as well as fuel lubricant transportation of Rig machine and other vehicles upto the site including cost of flusing charges, geological investigation etc all complete.
(i) From 0-50 meter
(ii) From 50 - 200 meter onwards
Providing and fixing insulation with thermaflex elastomeric nitrile rubber sheets complete with plastering of 20 mm thick insulation with thermaflex elastomeric nitrile rubber sheets for hot water & cold water pipes exposed to sun complete with Aluminium.
15 mm dia, nominal
20 mm dia, nominal
25 mm dia, nominal
32 mm dia, nominal
40 mm dia, nominal
50 mm dia, nominal
65 mm dia, nominal
80 mm dia, nominal
Providing and fixing brass automatic air vent at the top of each riser.
25mm diameter
Providing and fixing MS pipe puddle flanges of required size with 6mm thick MS plate of required size of suitable size properly fixed in RCC walls of water & Fire tanks, including necessary welding as per details shown on darwings and directions of Engineeer-in-charge for water tanks.
25mm dia pipe, 600mm long with 6 mm MS plate of size 250mm dia
32mm dia pipe, 600mm long with 6 mm MS plate of size 250mm dia
40mm dia pipe, 600mm long with 6 mm MS plate of size 250mm dia
50mm dia pipe, 600mm long with 6 mm MS plate of size 300mm dia
80mm dia pipe, 600mm long with 6 mm MS plate of size 300mm dia
100mm dia pipe 600mm long with 6 mm MS plate of size 400mm dia
150mm dia pipe, 600mm long with 6 mm MS plate of size 400mm dia
200mm dia pipe, 600mm long with 6 mm MS plate of size 600mm dia
250mm dia pipe, 600mm long with 6 mm MS plate of size 600mm dia
65 mm dia, nominal bore
80 mm dia, nominal bore
100 mm dia, nominal bore
Cost of drilling 200mm x150mm x230 meter deep bore well in all kind of soil and rock in rural or any other area for installation of pump sets with hydraulic DTH Rig machine all complete including supplying all materials tools drilling rig and air compressor and equipments, as well as fuel lubricant transportation of Rig machine and other vehicles upto the site including cost of flusing charges, geological investigation etc all complete.
Cost of drilling 200mm x150mm x230 meter deep bore well in all kind of soil and rock in rural or any other area for installation of pump sets with hydraulic DTH Rig machine all complete including supplying all materials tools drilling rig and air compressor and equipments, as well as fuel lubricant transportation of Rig machine and other vehicles upto the site including cost of flusing charges, geological investigation etc all complete.
Providing and fixing 80mm dia GI pipes to IS:1239 heavy class with fittings.
Supply, Lowering, installation & testing of submersible pumping set with 10 HP motor 4 stage pump suitable for 20/26/30/38/40/45/50 m3 hr. at 42/38/36/32/29/25/20 mtr. Head respectively. With Three Phase. (Model: 273/4)
Providing & fixing cable 3CX 6 sq.mm. From submersible pump to panel board of Aluminium cable.
Providing & fixing Panel Board for submersible pump fitted with DOL starter ammeter, voltmeter single phase preventer standard/indo/cop make MCB of off switch push bottom duly wired and made out of 16/18 SWG sheet.
Providing and fixing lever operated butterfly valve conforming to IS:13095-91 PIN 1.6 including necessary companion flanges, bolts and nuts complete.
80mm dia
Providing and fixing C.I. Wafer type flanged non-return valves with bolts, nuts, washers & companion flanges complete.
80mm dia
PUMPS & ALLIED WORKS
Supply, installation, testing & commissioning of vertical inline multistage pumping set (Imported) with Stainless steel-304 body, Stainless steel-304 impeller, Stainless steel-304 casing, shaft of Stainless steel-316 and C.I. base & head with mechanical seal, connected to a TEFC induction motor suitable for 415+/- 10% volts, 3 phase 50 cycles A.C. supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundations, 80x40 mm I section base plate bolted to cement concrete foundations complete.Vendor to submit performance curves and technical catalogue of the proposed model for review and information.
Filter Feed Pump ( Dom. Water)
Set of Three Pumps( 2 Working+ 1 Standby)
Capacity 450 LPM
Head 35 M.
HP 7.5 HP ( Approx.).
Filter Feed Pump ( Dom. Water)
Set of Two Pumps( 1 Working+ 1 Standby)
Capacity 4 LPS
Head 35 M.
HP 2.0 HP Approxi.
Water Make up Pump to STP & Irrigation Pumps
Set of Two Pumps( 1Working+ 1 Standby)
Capacity 200.0 LPM
Head 30 M.
HP 5.0 HP ( Approx.).
Irrigation Pumps
Set of Two Pumps( 1 Working+ 1 Standby)
Capacity 1.0 LPS
Head 30 M
HP 2HP Approxi.
Soft Water Transfer Pumps at STP Pump Room
Set of Two Pumps( 1 Working+ 1 Standby)
Capacity 250.0 LPM
Head 20 M
HP 5.0 HP ( Approx.).
Supply, Installation, Testing And Commissioning of Compact Self Contained Skid Mounted Hydropneumatic System As Follows:(A) Vertical, In-Line, Multisage, centrifugal pumps with SS-304 casing and impeller and SS-316 shaft, CI base & head CI material shouldbe CED coated TEFC motor (with mechanical seal) with single VFD suitable for automatic operation and delivering the specified discharge at the specified head,VFD should be of class IP-20 with pressure vessel, pressure vessel should be matching of specied requirement of pump.(B) b. External Pump mounted or wall mounted microprocessor PID controller and frequency inverter integrated in a single body or as separate components with pressure sensor transmitter minimum two lined LCD display, diodes to indicate pump ready, pump running and fault and capable to communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocall through RS485 port. System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equiped with dry running protection. ( C) Complete (Skid mounted wall mounted / floor mounted) electrical control panel comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiring and any other necessary imports etc. (list to be provided by the vendor) (D)Precharged diaphram pressure vessel with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc complete.(E)Set of accessories such as pressure switches, pressure transducers, inter connecting power and control cabling etc. complete(F) Accessories like pressure gauge, MS base frame (Synthetic enamel painted over a coat of primer)(G) GI suction and delivery header with flanges for inlet connection, common outlet header with flanges for outlet connections as required, and inter connecting piping with flexible connections, eccentric type reducers etc. all necessary indigenous accessories like valves, strainer & NRV as required to complete the installation.
Domestic Water hydropneumatic Pumps(For Hospital & College Blocks)
Set of Three Pumps( 2 Working+ 1 Standby)
Capacity 250.0 LPM
Head 65 M
HP 10 HP ( Approx.).
Domestic Water hydropneumatic Pumps(For Residential blocks)
Set of Three Pumps( 2 Working+ 1 Standby)
Capacity 200.0 LPM
Head 65 M
HP 10 HP ( Approx.).
Domestic water supply transfer pumps
No. of pumps 3 (2 Working + 1 Standby): 1 set
Water Flow Rate 4.0 LPS each
Head : 50 M
Min. Motor HP : 3.0 H.P. (Each)
Flushing Water hydropneumaticPumps at STP Pump Room
Set of Two Pumps( 1 Working+ 1 Standby)
Capacity 150.0 LPM
Head 65 M
HP 6.0 HP ( Approx.).
Flushing Water supply transfer pumps
No. of pumps 2 (1 Working + 1 Standby): 1 set
Flow Rate : 4.0 LPS each
Head : 50 M
Min. Motor HP : 2.0 H.P. (Each)
Domestic Water booster Pumps at Terrace(For Boys & Girls Hostel)
Set of Three Pumps( 1 Working+ 1 Standby)
Capacity 150 LPM
Head 20 M
HP 2.5 HP ( Approx.).
Domestic Water booster Pumps at Terrace(For Nurse Hostel , Tpye-III , PRA & Guest House)
Set of Three Pumps( 1 Working+ 1 Standby)
Capacity 175 LPM
Head 20 M
HP 2.5 HP ( Approx.).
Domestic Water booster Pumps at Terrace(For Resident Doctor & Tpye-IV )
Set of Three Pumps( 1 Working+ 1 Standby)
Capacity 200 LPM
Head 20 M
HP 2.5 HP ( Approx.).
Domestic Water booster Pumps at Terrace(For Interns Hostel-Male & Female & Tpye-V and Sadar Hospital )
Set of Three Pumps( 1 Working+ 1 Standby)
Capacity 250 LPM
Head 20 M
HP 2.5 HP ( Approx.).
Supply, installing, testing and commissining of submersible single stage single entry pumps with C.I.body and C.I. two vane enclosed type impeller connected to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphram and bend, vertical discharge pipe, guide pipe and chain in built level controller, sequence running controller, dry running Protection complete in all respects. Complete With media saturation arrangement twin lobe rotary air blower with motor , base frame , pulleys , v belts, drives guard suction pipe , accessories, painting, testing and commissioning complete with approved quality and make as required as per instruction of site incharge.
(Pumps shall be installed in a set of two pumps One working and One standby)
Water Supply Pump Room & basement drainage
(Pumps to be suitable to handle solids upto 12 mm size)
Capacity - 5.0 LPS (Each)
Head - 10 M
H.P. - 3.5 HP Approx.
Sewerage Sump Pump at STP area
(Pumps to be suitable to handle solids upto 40 mm size)
Capacity - 5.0 LPS (Each)
Head - 10 M
H.P. - 5.5 HP Approx.
Providing stainless steel pipes conforming to EN 10312 standard complete with press type fittings for Hot and cold water supply, RO & domestic water supply system capable to withstand temperature upto 1100 centigrade and pressure upto 16 bars made from 316 L grade-Material no. 1.4404 (X2CrNiMo17-12-2) of annealed and pickled stainless steel sheet, with ends deburred at 900 and with length of 3 meters. Pipe qualifying to 100% eddy current, 100% hydrostatic tested and air-under water tested under 10kgs. Fittings also conforming to EN 10312 standard in 316 L stainless steel grade of approved make in accordance with DVGW regulation such as tees, coupling, elbow, male adapter, connectors etc with Black grooved O-ring of EPDM material which can withstand temperature upto -200 to 1100 C including suitable connection as per site requirement. Direct contact of stainless steel pipes and fittings to galvanized iron should be avoided by inserting approved type of filler material as per project manager’s/consultant requirement. Flanges, clamps with hanger at a spacing of 2 m centre to centre min or as required etc. necessary adapters for GI/copper and CP fittings, jointing, sundries, cutting holes in walls/floors/slabs & making good complete.
54mm dia
76mm dia
89mm dia
108mm dia
Providing and fixing cast iron wafer type butterfly valves (PN-10) complete with 2 nos. matching flanges (Table-E),bolts, nuts, 3.0 mm thick insertion neoprene gasket.
50mm dia
65mm dia
80mm dia
100mm dia
Providing and fixing of cast iron dual plate wafer type check valves (PN-10) including 2 nos. matching flanges ( Table-E), nuts, bolts, 3.0 mm thick thick insertion neoprene gasket.
65mm dia
80mm dia
100mm dia
Providing and fixing resilient rubber neoprene lined style arch vibration eliminators suitable for raw water upto 45 deg.C. Temperature working pressure upto 8 Kg/Sqcm.
50mm dia
65mm dia
80mm dia
Providing and fixing heavy duty armoured cables 1.1 KVA grade including necessary support clamps at ceiling level and connection lugs complete in all respects.
Power cable Copper 3 core 10 sq.mm
Power cable Copper 3 core 6 sq.mm
Power cable Copper 3 core 1.5 sq.mm
Providing and fixing CI Y type suction strainer with gunmetal or brass internal parts installed outside water tanks.
100 mm dia.
150 mm dia.
Supplying, installing, testing and commissioning controllers with low volatage relays, stainless steel probes and PVC shroud wiring from tank top to probles of required.
For Filter Feed Pump:
To start pump when water level is low in U.G. tank (Domestic water) and shut off pump when U.G. tank (Domestic) is full. Also to stop when water level is low in raw water underground tank.
For Sump Pumps:
To start pump when water level is high in sump and shut off pump when sump is empty. Both pumps are start when sump is over flowing.
For Over Head Tanks:
To start pump when water level is high in sump and shut off pump when sump is empty. Both pumps are start when sump is over flowing.
Providing and fixing galvanized slotted cable trays supported from ceiling at intervals of 60 cms on both ends including cable clips with nuts and bolts welding of support rods with ceiling inserts or by drilling and installing expandable fasteners, cutting and making good complete
300 mm wide (for horizontal at ceiling level)
150 mm wide (For vertical drops)
Providing and laying G.I. "C class" pipes and fittings conforming to IS: 1239 (Heavy class) Jointing with flanged joints including nuts & bolts, 3.0 mm thick compressed asbestos gasket etc, including with fittings, union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1:2 (1cement : 2 coarse sand) as directed by Project Manager complete in all respects.
50mm dia
65mm dia
80mm dia
100mm dia
150mm dia
Painting of G.I. pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc chromate primer as directed by the Engineer-in-Charge (shade as per pipe colour code).
50mm dia
65mm dia
80mm dia
100mm dia
150mm dia
ELECTRICAL PANEL WORKS
MCC –1 for Plumbing system
Incoming
100 amps TPN MCCB with the following accessories:
c. Phase indicating lamps protected by 2 amp SP MCB 3 Set
Bus Bar
150 amps TPN aluminium bus bar with heat shrinkable insulation sleeves.
Outgoings
e. Spare MCB’s of following capacities:
i. 32 amps TPN MCB’s 3 No.
ii. 20 amps TPN MCB’s 3 No.
f. Necessary cable alleys, internal wiring, and interlocking, earthing for all equipment shall also included
Notes :
a. All MCCBs shall be of 35 KA breaking capacity and suitable for motor duty application.
b. Provision shall be made for providing potential free contacts to all pumps starters for connection to BAS
c. Provision shall be made to ensure system protection from dry running of the pump
MCC - 1 For Plumbing System as described above.
WATER TREATMENT EQUIPMENTS
Supply Installation,Testing & Commissioning of vertical self supporting Dual Media Filter fabricated from MS sheet as per IS: 2825, (minimum thickness of shell & Dish ends as per manufacturer design) pressure gauges, sample cock, GI class 'C' face piping, CI butterfly valves and all accessories , with initial charge of filter media including anthracite, painting inside with epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint, testing and commissioning complete.
For Domestic Water Supply
Capacity- 48000 LPH
Filtration rate- 14000 LPH/M2
Filter Dia approx. - 1750 mm (Approx.)
Working pressure: 3.0 Kg/sq cm.
Test pressure : 4. 5 Kg/sq cm
For Domestic Water Supply
Capacity- 7200 LPH
Filtration rate- 14000 LPH/M2
Filter Dia approx. - 1200 mm
Working pressure: 3.0 Kg/sq cm.
Test pressure : 4. 5 Kg/sq cm
Supply Installation,Testing & Commissioning of vertical self supporting Activated Carbon Filter fabricated from MS sheet as per IS: 2825, (minimum thickness of shell & Dish ends as per manufacturer design) pressure gauges, sample cock, GI class 'C' face piping, CI butterfly valves and all accessories , with initial charge of filter media including anthracite, painting inside with epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint, testing and commissioning complete.
For Domestic Water Supply
Capacity- 48000 LPH
Filtration rate- 14000 LPH/M2
Filter Dia approx. - 1750 mm
Working pressure: 3.0 Kg/sq cm.
Test pressure : 4. 5 Kg/sq cm
For Domestic Water Supply
Capacity- 7200 LPH
Filtration rate- 14000 LPH/M2
Filter Dia approx. - 1200 mm
Working pressure: 3.0 Kg/sq cm.
Test pressure : 4. 5 Kg/sq cm
Supply Installation,Testing & Commissioning of metering pump type chemical doser with 100 lits. HDPE solution tank,injection fitting assembly,suction and delivery hose upto the point of injection, capacity 0-6 lph, complete in all respects.
Chlorination of Domestic Water
Providing, fixing, testing & commissioning of MSEP water softening plant (suitable for 3 Kg/Sqcm working pressure) complete with initial charge with T-40 NA Resin, multiport valve with built in ejector for controlling all operations), regeneration system and HDPE tank, pressure gauge at inlet, outlet and back wash (each with isolation cock), valves, fittings and water hardness testing kit & associated works. Softener shall be suitable for the following duty:
Raw water hardness 500 Mg/L
Treated water hardness 100 Mg/L
Regeneration Period 10 Hrs.
Capacity : 2.06 LPS
SOLAR WATER HEATERS
Solar Water Heating System-500 LPD
Providing and fixing Solar Hot Water indirect Heating System using heating liquid medium comprising of flat plate solar panels, including all interconnecting insulated G.I. piping, primary and secondary recirculation pumps, pressure type insulated hot water tank, , outlet, Y stainer and a water meter on the inlet, air release valve all mounted on galvanized MS sections complete with connection with the existing piping. Comparising of following:-
Five Nos of. flat plate solar collector panels of 8 Sqm size approx. the panels enclosed in insulated collector boxes with single piece toughned glass 4 mm thick and fixed with heat resistant gasket.
One No. Integrated heat exchanger with drain down vessel 9 Ltrs. Capacity,designed so as to provide heat exchange between solar collectors and 500 ltr tank complete with drain down tank. The cold water heated after passing through heat exchanger to be stored in hot water tank. Necessary pumps and controller for automatic operations to be provided. including MS painted frames for the same.
M.S Horizontal hot water mixing tank of 500 ltr capacty shall be made out by of 4mm thick M.S. plate and inside lining of 1.0 mm thick stainless steel grade 316 sheet , out side steel primer including 50 mm thick glass wool slab insulation (density of glass wool 64 Kg/Sqm.) & 24 SWG aluminum sheet cladding outside the tank. Tank shall be provided with flanges for inlet outlet, over flow/ drain connection & Vent pipe with M H cover of 450 mm internal dia., Temperature and pressure release valve should be on top of water storage tank All the valve & accessories shall be suitable for an operating pressure of 6.0 kg/sqm including electric back up of 1 x 4.5 KW
Primary circulation pump 2 Nos (1W+1S) for circulation of fluid from Solar panels to heat exchanger.
Secondary circulation pump 2 Nos (1W+1S) for circulation of fluid from heat exchanger to hot water mixing tank.
One Lot of Inter-connected insulated G.I. piping insulated with 9 mm thick nitrile rubber heat resitant insulation sections ( Vidoflex or equiv.) and valves with outer mechanical protection of aluminium sheet cladding.
Solar Water Heating System as Describe Above
Supply , instalation, testing & commissioning of Cubical type branch distribution boards( BDB) of the following types made out of 14 gauge (2 mm thick) CRCA sheet complete with the accessories i/e. interconnections with suitable copper solid strip connections 100 A & above and with copper wires below, painting etc. and complete with supplying & fixing the following boardsetc. as required.
Branch Distribution Board for 8x500 LPD System
1 No. 125 AMP rating TP Modulded case circuit breakers with neutral link, front operated handle & thermal magneticrelease (35 Ka)
1 Set 125 Amp 4 Bars Tinned Cu. Bus Bar
1 Set LED type Indication lights
1 No. Digital Voltameter (0-500 V)
1 No. Digital Ammeter (0-125 A )
1 Set CTs for Ammeter 125/5 A ratio
3 Nos. 2 A SPMCB
Outgoing
08 Nos 25 A TP MCB , 10 KA (6+2 Spare)
03 Nos 63 A TP MCB , 20 KA for Electric back up supply.
The System is based on temprature difference and the system will operate automatically based on thermostat for startup and shutdown of Primary,Secondry, Receiculation pump and Heating elements on temprature differential.
Electric Panel as Describe Above.
Supply, installation, testing & commissioning of vertical inline multistage pumping set (Imported) with Stainless steel-304 body, Stainless steel-304 impeller, Stainless steel-304 casing, shaft of Stainless steel-316 and C.I. base & head with mechanical seal, connected to a TEFC induction motor suitable for 415+/- 10% volts, 3 phase 50 cycles A.C. supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundations, 80x40 mm I section base plate bolted to cement concrete foundations complete.Vendor to submit performance curves and technical catalogue of the proposed model for review and information.
Hot Water Recirculation Pumps
Set of two pumps (1 Working + 1 Standby)
Capacity - 10 LPM
Head - 12.0 Mtr.
H.P. - 1.0 HP (Approx.)
Solar Hot Water Recirculation Pumps
Set of two pumps (1 Working + 1 Standby)
Capacity - 5 LPM
Head - 12.0 Mtr.
H.P. - 1.0 HP (Approx.)
Five Nos of. flat plate solar collector panels of set of 8 Sqm size approx. the panels enclosed in insulated collector boxes with single piece toughned glass 4 mm thick and fixed with heat resistant gasket.
VALVES AND FITTINGS IN HOT WATER MIXING TANK
65 mm PN10 Butterfly Valve. Cold water inlet
65 mm PN10 Butterfly Valve. Hot water outlet
65 mm PN10 Butterfly Valve. For drain
50 mm PN10 Butterfly Valve. For return line hot water
40 mm PN10 Ball Valve. For heat pump inlet and out let
Safety valve size 25 mm
Pressure gauge(0-10 kg/cm2, 4 inch dial with valve
Temp. gauge(0-100 Deg. C, 4 inch dial (Thermo well type)
Y-Strainer 40 mm C.I. heat pump inlet
Check Valve CI 65 mm cold inlet line
NRV40 mm HEAT PUMP hot water line
Supply, installation, testing & commissioning of heavy duty PVC insulated copper armoured cables suitable water submerged condition, 1.1KVA grade including necessary support clamps, complete in all respects.
3 x 2.5 sq. mm
3 x 6 sq. mm
EXTERNAL WATER SUPPLY & IRRIGATION SYSTEM
Providing stainless steel pipes conforming to EN 10312 standard complete with press type fittings for Hot and cold water supply, RO & domestic water supply system capable to withstand temperature upto 1100 centigrade and pressure upto 16 bars made from 316 L grade-Material no. 1.4404 (X2CrNiMo17-12-2) of annealed and pickled stainless steel sheet, with ends deburred at 900 and with length of 3 meters. Pipe qualifying to 100% eddy current, 100% hydrostatic tested and air-under water tested under 10kgs. Fittings also conforming to EN 10312 standard in 316 L stainless steel grade of approved make in accordance with DVGW regulation such as tees, coupling, elbow, male adapter, connectors etc with Black grooved O-ring of EPDM material which can withstand temperature upto -200 to 1100 C including suitable connection as per site requirement. Direct contact of stainless steel pipes and fittings to galvanized iron should be avoided by inserting approved type of filler material as per project manager’s/consultant requirement. Flanges, clamps with hanger at a spacing of 2 m centre to centre min or as required etc. necessary adapters for GI/copper and CP fittings, jointing, sundries, cutting holes in walls/floors/slabs & making good complete with including trenching and refilling etc. ( External work).
28 mm dia
35 mm dia
42 mm dia
54 mm dia
76 mm dia
89 mm dia
108 mm dia
Providing, laying, Jointing, Testing and commissioning of UPVC pressure pipes of 10Kg/Sqcm pressure rating class 5 (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead upto 50m complete, compaction and consolidation Including laying cement concrete 1:2:4 alround UPVC pipe including bed concrete and thrust blocks at bends as per standard design (For garden hydrants).
Providing and fixing of cast iron wafer type butterfly valves (PN 10) complete with 2 nos. matching flanges ( table-E) , bolts, nuts, washers 3 mm thick insertion neoprene gasket conforming to IS 13095.
100 mm dia
Providing and fixing motorised butterfly valve, IP- 67, with float type sensors suitable for 240 volts with working pressure rating of not less than 5kg/cm2, torque of motor should be capable to open and close valve at 5 kg/sq.cm pressure, with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including 03 Nos butterfly valves along with byepass piping, necessary cables, conduits, upto junction box ( upto 6 mt qty approx) etc. complete.
50 mm dia
SEWAGE TREATMENT PLANT
Design, supplying, installing, testing & commissioning of Combine Sewage and Effluent Treatment Plant for 540 KLD (500 KLD STP + 40 KLD ETP) capacity, electro mechanical system based on SBR technology. & (150 KLD STP+ 20 KLD ETP)lectro mechanical system based on Advanced MBBR technology. (excluding all Civil & construction work)
Anticipated effluent parameters before treatment:
BOD 250-400 mg/lt
COD 600-800 mg/lt.
SS 200-450 mg/lt.
Oil & Grease upto 20-30 mg/lt
Desired discharge standard after UF are as below:
BOD Less than 5 Mg/L
S. Solids Less than 5 Mg/L
COD Less than 40 Mg/L
Oil & Grease Less than 1 Mg / L
Combined Sewage treatment and Effluent treatment plant shall include the following Civil Units : (Civil Scope)
Bar Screen cum Oil & Grease Chamber
Sewage equalization tank/sump
Reaction and Settling tank for ETP
SBR Tank
Chlorine Contact Tank
Sludge Holding Tank
UF Feed Tank
UF Permeate Tank
Soft Water Tank
Supply, installation, testing & commissioning of 2 Nos Stainless Steel Perforated, Corse Type Bar Screen Size 500mm x 750 mm with suitable garbage lifting arrangement. Make: Jash/Huber/Wastech/ Johnson/BS enviro
Supply, installation, testing & commissioning of level indicators and controllers for automatic operation of the complete system with high/low level alarm complete with auxillary NO/NC contacts. (Required in equalization tank, chlorine contact tank, sludge holding tank ).
Supply, installation, testing & commissioning of Submersible, non clogging type pumps capable of handling solids upto 20mm having CI casing & CI impeller complete with mechanical seal & all accessories, motor of required capacity. Delivery header with isolation valve, pressure gauge on delivery line with isolation cock. Pumps shall have following duty Make-Wilo/Grundfos/KSB/KBL.(1 Set=1Working+1Standby).
Submersible Sewage Transfer Pumps
Flow Rate (each) = 35 m3 / hr
Head = 8-10 Mtr
Submersible Sewage Transfer Pumps
No. of pumps 2 (1 Working + 1 Standby): 1 set
Flow Rate (each) = 7.5 m3 / hr
Head = 8-10 Mtr
Plant room sump pump (For ETP)
Flow rate = 20 m3/hr
Head = 15 Mts
Cost shall be inclusive of rigid (MS C Class) /PVC Flexible Pipe 100 mm dia , rope for lifting pump from sump to outside.
Providing and fixing horizonal,centrifugal sludge transfer pump . The pumps shall have CI casing, CI Impeller with mechanical rotary shaft seal. Motor to be suitable for including all necessary piping valves and other accessories complete as required. Solid Handling capacity 7-8 mm. (1 Set=1Working+1Standby).
Sludge Recirculation Pump
Capacity : 8 Cum/hr.
Head : 8-10 mtrs.
Air diffusion system shall include the following:
Supply, installation, testing & commissioning of twin lobe, rotary Air blower capable of delivering 600 cum/hr @ 5000mmwg of free air at required pressure driven through “V” belt or directly coupled through flexible coupling to a TEFCmotor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply. Make- Everest/ Usha/Beta (1 Set=1Working+1Standby).
Air Blowers
Flow Rate (each) = 600 m3 / hr @5000mmwg
Supply, installation, testing & commissioning of twin lobe, rotary Air blower capable of delivering 150 cum/hr of free air at required pressure driven through “V” belt or directly coupled through flexible coupling to a TEFCmotor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply. Make- Everest/ Usha/Airvac
Air Blowers
No. of blower 2 (1 Working + 1 Standby): 1 set
Flow Rate (each) = 150 m3 / hr
Air piping shall comprise of MS C Class for NOn submerged and SS 304 for all submerged air lines & Plant room complete with all fittings such as tees, crosses, plugs, sockets, elbows, reducers, paint,supports & clamps, making good the wall wherever required. Contactor to submit detailed P & I indicating their proposal.
Providing and fixing all interconnecting piping (as described below) and isolation control valves for making the system complete. The piping material shall be MS 'C' class.
SS 304 : Submerged air piping .
MS Epoxy : Air piping & pumped effluent riser ( non-submerged)
MS C Class piping : Pumped effluent & tank
PVC Piping : All overflow from the tanks
Supply, installation, testing & commissioning of SBR Package with 2 tank system, Fully automatic system with Diffused aeration system comprises of , EPDM air diffusers and air grid in uPVC. Moving decanter with thickness more than 3mm shall be installed in reactor tank for decanted water extraction, MOC of decanter shall be SS-304 (Make - TATA / Jindal) driven by Geared motor of suitable Power. Inlet of sewage water decantation and aeration shall be automatic and PLC controlled with the help of automatic valves or by equipment arrangement. SBR cycle shall be auto controlled and continous feedback level transmitter (Ultrasonic or Hydrostatic) shall be installed in each reactor tank (1 no DO sensor, 1 no level transmitter and 1 no PH transmitter). Plant shall give the water quality as above & as per Specification. Decanter Make: C-TECH/PRIMER TECH//BS ENVIRO
Supply, installation, testing and commissioning of MBBR media having porous structure with very high syrface area of 2500 m2/m3. The MBR media shall have very high organic loading rate and ability to retain microorganism inside the structure also.
Make: Kurary -Japan/Anox Kaldness-USA/Headworks-USA
Supply, installation, testing and commissioning of PVC tube deck settling media to be installed in Tube Settler Tank alongwith retainer plates and suitable sludge removal arrangement either by pumps or any other suitable arrangement. Capacities, length, width,depth, of the media shall be enough for proper functioning of STP. Make-PP Aqua MM Aqua
Supplying, installing, testing & commissioning of centrifugal\ feed pumps, CI body, CI impeller. motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, stainer at suction. The pump shall be suitable for 415±10% volts 3 phase AC supply Make-Kirloskar/M&P/Johnson) (1 Set=1Working+1Standby).
Filter feed pumps:
Capacity : 30 Cum/hr.
Head : 25-30 Mtrs
Filter feed pumps:
Capacity : 15 Cum/hr.
Head : 25-30 Mtrs
Softner feed pumps:
Capacity : 10 Cum/hr.
Head : 20-25 Mtrs
Supplying, installing, testing and commissioning of MSEP vessel filter with all necessary accessories. Filter shall be suitable for minimum working pressure of 5 kg / cm2 and shall include media, standard fittings like pressure gauges, sampling cock, rinse drain, vacuum breaker etc. The MS sheet thickness for tank shall be min. 6mm and for dishess shall 8mm. The internal surfaces of tank shall be treated with epoxy coaing and external surface with primer and anticorrosive enamel paint (Min. 2 coats). Make: Thermax/Ion Exchange/Hydrocon/BS enviro.
Multigrade pressure sand filter
Flow rate : 30 Cum/hr
Filteration velocity : 15 cum/hr/sqm
Filter Diameter : 1600 MM
Shell Thickness: 8 mm
Disch Thickness: 10 mm
Corrosion allownace: min 2 mm
Multigrade pressure sand filter
Flow rate : 15 Cum/hr
Filteration velocity : 15 cum/hr/sqm
Filter Diameter : 1500 MM
Shell Thickness: 6 mm
Disch Thickness: 8 mm
Corrosion allownace: min 2 mm
Activated Carbon Filter
Flow Rate : 30 Cum/hr
Filteration velocity : 15 cum/hr/sqm
Filter Diameter : 1600 mm
Shell Thickness: 8 mm
Disch Thickness: 10 mm
Corrosion allownace: min 2 mm
Activated Carbon Filter
Flow Rate : 15 Cum/hr
Filteration velocity : 15 cum/hr/sqm
Filter Diameter : 1500 mm
Shell Thickness: 6 mm
Disch Thickness: 8 mm
Corrosion allownace: min 2 mm
Providing, fixing, testing & commissioning of MSRL water softening plant (suitable for 3 Kg/Sqcm working pressure) complete with initial charge with T-40 NA Resin, Butterfly valve with built in ejector for controlling all operations), regeneration system and HDPE Brine tank with SS Agitator, pressure gauge at inlet, outlet and back wash (each with isolation cock), valves, fittings and water hardness testing kit & associated works. Softener shall be suitable for the following duty: Make: Thermax/Ion Exchange/Hydrocon/BS enviro.
Raw water hardness 500 Mg/L
Treated water hardness 100 Mg/L
Regeneration Period 10 Hrs.
Capacity : 10000 LPH, OBR: 100
Supply, installation, testing & commissioning of UV system for purification of recycled water from STP. With all accessories complete in all respect Make-Alfa/Sukruit
Cap: 30 m3/h with all part in SS 316. The UV should have min inetnsity of <60000 microseimens/cm2
Supply, installation, testing & commissioning of UV system for purification of recycled water from STP. With all accessories complete in all respect Make-Alfa/Wastech/Hydrocon).Cap: 15 m3/h with all part in SS 316. The UV should have min inetnsity of <60000 microseimens/cm2
Supply, installation, testing and commissioning of filter press of Suitable Capacity 16"x 16"x 18 Plates with CI frame, PP plates with filter cloth interconnecting piping and poly dosing system complete. (Make- Auro/NM Patel/ Pharmatech)
Supply, installation, testing and commissioning of Basket type Centrifuge of Suitable dia 900 mm with interconnecting piping and poly dosing system complete. Make: Humboldt Wedag/Hiller/Alfa Laval
Supply, installation, testing & commissioning of positive displacement type screw slurry pump with MS casing, SS-strator with internal rubber lining, gland packing seal, solid handling capacity upto 7 to 10% of the effective percentage of sludge and direct drive with motor.Make-UT/Roto/Technoflow.(1 Set=1Working+1Standby)
Sludeg Feed Pump
Capacity : 2 m3/hr
Head : 40 mtrs. (1W+ 1S)
Supplying, installing, testing & commissioning of Submersible Mixer 1.5 HP for Anoxic Tank. Make: Aqua Italy/ABS
Electrical Panel- Motor Control Centre
Motor Control Centre
Incoming
600 amps TPN MCCB with the following accessories:
c) Phase indicating lamps shall be protected by 2 amp SP MCB 3 sets.
Bus Bar
400 amp TPN (15 KA) copper bus bar with heat shrinkable insulation sleeves.
Outgoing
b) Spare MCB's of following capacities
I. 32 amps TPN MCB's 3 Nos.
a) All MCCB's / MCB's shall be of 15 KA breaking capacity and suitable for motor duty application.
b) All motor starters shall be provided with Auotmatic level controller.
c) DOL starters shall be used for moters below 10 HP and Star-Delta Starters for other motors.
d) Provision shall be made for providing potential free contacts to all pumps starters
MCC for all STP equipments/ pumps as described in sub head-A with provision for all future pump air blower etc. Make: Brisanzia
MCC for all STP equipments/ pumps as described in sub head-A with provision for all future pump air blower etc. Make: Brisanzia
Make: Vendor Specific with CPRI Approval
Supplying, installing, testing & commissioning of Cables , Conector, Cable Trays, to make Electrical Installation Complete.
Supplying, installing, testing & commissioning of Cables , Conector, Cable Trays, to make Electrical Installation Complete.
Supplying, installing, testing & commissioning of Electromegnatic Flowmeter of min 3 inch dia at Inlet and Outlet of system. Make: FORBES MARSHALL /SIEMENS /HACH
Supplying, installing, testing & commissioning of Electromegnatic Flowmeter of min 3 inch dia. Make: Krohne Marshall/Nivo/Manas
Supply, Fabrication, installation, testing and commisioning of phyisco chemical treatment based effluent treatment plant with effluent handling capacity 40 m3 per day. The ETP shall be designed as water retaining structures, with necessary chemical dosing as required by the manufacturer's design. All the equipment, piping, and pumps to be housed in the ETP , inlet, outlet, overflow, vent, etc. The Plant shall be complete with a central Electrical Power and Control panel fully pre/site wired and with all power and control cables to all pumps and equipment including all instrumentation, level and other controls. Note: Treated effluent will be mixed in Filter Feed Tank/CCT of STP.
Effluent from labs etc. Some solvent/ chemical waste originating typically from College complex shall also be discharged into the ETP. Design to take consideration of same.
Daily average flow : 5 Cum/hr
BOD : 250 - 600 mg/l
S. Solids : 400 - 650 Mg/l
COD : 600 - 1200 mg/l
Oil & Grease : 50-140 mg/L
Effluent discharge standard after chemical treatment before mixing to CCT :-
S. Solids : Less than 100 mg/l
COD : Less than 100 mg/l
Oil & Grease : Less than 5 mg/l
BOD : Less than 30 Mg/L
The ETP shall consist of following units but not limited to these unit as may be required by the manufacturer's design. MS PVC coated rungs in all tanks & Platform for maintenance etc. complete as required.
SS Perforated screen having provision for chain lifting arrangement etc. complete as required ( 1 SET)
Collection cum Equalization tank including provision for aeration will be kept to avoid any smell problems in RCC Construction (Civil contractor Scope)-10 Cum ( 1 SET)
Reaction tank with air diffuser and piping complete of adequate capacity. Fine air bubble jet diffuser with EPDM seat minimum number of diffusers to be provided as per manufacturer's recommendations in RCC Construction.
Secondary clarifier tank, Tube Deck Media, hopper bottom type with arrangement of deep well, baffle wall, scum removal arrangement, outlet launders with arrangement of lifting sludge from the bottom etc. complete as required in RCC Construction.(1 SET)
Providing and fixing all piping (as described below) and isolation control valves, non return valves etc. for making the system complete.
PVC piping (10kg/sqcm) - For all submerged waste water piping.
MS (C Class) - For all exposed air piping and flexible stainless steel pipe for submerged air piping.
GI (C class) for all other water piping. ( 1 LOT)
Providing and fixing all instrumentation eg. Pressure guages, level controllers, sensors, rotametres for air, water etc. for making the system complete (1 LOT)
EQUALIZED WASTE WATER TRANSFER PUMPS :
Providing, installation, testing & commissioning of Horizontal / Submersible centrifugal pumps solid handling (min. 20 mm) pumps. The pumps shall be made of CI casing, bronze Impellar, CS shaft & sleeve, Mechanical Seal are connected to a TEFC induction motor mounted on a common channel base frame with coupling guard, 150 mm dia pressure gauge with GM isolation cock, suitable vibration eliminator pads of approved design. Motor to be suitable for 400/440 V, 3 Phase, 50 cycles AC power supply, including all necessary piping, valves and other accessories and concrete foundation complete as required.
Capacity : 5.0 M3/hr @ Discharge Head 12 M head (1 Working + 1 Standby) (1 SET)
Mono block centrifugal Sludge Transfer Pumps (2 Nos. - One working & one standby ( 1 SET)
(Solid handling cap. 6 mm)
Flow rate (each) = 1 m3 / hr
Head = 8-10 Mtr
Providing and fixing lime/alum/polyelectrolyte dosing system consisting of ABS lime dosing pump (0-6 lph) with 100 l HDPE tanks including all piping from the dozer to the reaction tank etc. complete in
Contractor shall include all electrical and mechanical items as required to operate the system automatically and also include in his rates any other components/tanks/ equipment/ etc. required to complete the job as required. Only main power supply with the earthing to be (ETP+STP) main control panel shall be provided by the owner through other agencies. The electrical panle will also include all the required NO/NC contacts, contactors etc. required to provide BMS connectivity.
Bypass arrangement shall be provided such that equalization tank pump can be used to pump out sewage to external manhole incase of maintenance of ETP.
All ETP system complete in all respect exclude all Civil & construction works.
Design, supplying, installing, testing & commissioning of EFFLUENT Treatment Plant
Nature of Waste - Hospital waste
Daily average flow - 20 cum/day
Anticipated effluent parameters before treatment:
BOD5 - 300 mg/lt
COD - 800 mg/lt.
Oil & Grease - 7 mg/lt.
Ecoli - >106 MPN
Sulphate - 29
Desired EFFLUENT discharge standard as well as meeting norms for Gardening and washing set makeup etc after treatment are as below:
BOD5 - Less than 30 Mg/L
COD - Less than 250 Mg/L
Oil & Grease - Less than 5 Mg / L
Ecoli - < 103 MPN
Sulphate - Less than 10 Mg/L
Effluent treatment plant shall include the following items:
Inlet Sump
Bar Screen Chamber
Effluent equalization tank
Oil & Grease chamber (Oil Skimmer)
FAB Tanks
Tube Settler
Clear water Tank
Sludge Holding Tank
Filtration through DMF & ACF
Air Blowers, Pumps & equipment
Piping, valves etc
Electrical Panel & Cabling
Filter press along with screw pump
Instrumentation like Metering devices, Sensors etc
Chlorination
Supply, installation, testing & commissioning of 2 Nos. Stainless Steel Corrugated Perforated Bar Screen havin size 500x800x5mm thickness with minimum 10 mm mesh size
Supply, installation, testing & commissioning of level indicators and controllers for automatic operation of the complete system with high/low level alarm complete with auxillary NO/NC contacts. (Required in equalization tank, chlorine contact tank, sludge holding tank).
Supply, installation, testing & commissioning of non clogging type centrifugal type pumps capable of solids handling upto 8 mm having CI casing & CI impeller complete with mechanical seal & all accessories, motor of required capacity. Delivery header with isolation valve, Pumps shall have following duty.
Equalization Transfer Pumps
ONE set - (1 Working + 1 Standby)
Flow rate (each) = 2 m3/hr
Head = 10.00 Mtr
Motor HP = As per manufacturer recommendation
Make-Kirloskar/CRI/KSB
Supply, installation, testing & commissioning of non clogging type Sludge transfer pumps CI material complete with mechanical seal & all accessories, motor of required capacity.Suction header with Isolation Butterly valves, Delivery header with isolation Butterly valve,NRV's. Pumps shall have following duty.
Sludge Transfer pumps
ONE set - (1 Working + 1 Standby)
Flow Rate (each) = 2.0 m3 / hr
Head = 8-10 Mtr
Motor HP = As per manufacturer recommendation
Make-Kirloskar/CRI
AIR DIFFUSION SYSTEM
Air diffusion system shall include the following:
Capable of delivering 20.0 cum/hr of free air at 0.55 kg/cm2 driven through “V” belt or directly coupled through flexible coupling to a TEFCmotor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply.
Twin type rotary air blowers.
ONE sets - ( 1 Working + 1 Standby)
Make-Beta/Airvac/SMW/Akash
Capacity- 25 m3/hr
Air piping shall comprise of pipes droppers / laterals with UPVC/MS Class (epoxy coated) Header complete with all fitting such as tees, crosses, plugs, sockets, Elbows, reducer,supporters & clamps, Puddle flange etc cutting chases and making good.
Non-clog type air dispersion system in the form of Air grid , Bottom faced holes at designed angles for FAB reactors / retreviable type diffusers & Top face for Equilisation Tank,Flocculation chamber,Sludge Holdng Tank,
Providing and fixing all interconnecting piping with all required isolation control valves for making the system complete functional as per site.
Supply, installation, testing and commissioning of MBBR media to be installed in FAB Tank
Supply, installation, testing and commissioning of suitable PVC tube deck settling media to be installed in Tube Setller tank alongwith suitable sludge removal arrangement either by pumps or air lifting pumps .
Dosing Systems
Supply, installation, testing & commissioning of Polyelectrolyte dosing system comprising of 100 ltrs HDPE tank with 0- lph electronic metering type pump in flocculation chamber
Supply, installation, testing & commissioning of Alum dosing system comprising of 100 ltrs HDPE tank with 0-6 lph electronic metering type pump in flocculation chamber
Supply, installation, testing & commissioning of Lime dosing system comprising of 100 ltrs HDPE tank with 0-12 lph electronic metering type pump in flocculation chamber.
Supply, installation, testing & commissioning of Chlorine dosing system comprising of 100 ltrs HDPE tank with 0-12 lph electronic metering type pump in flocculation chamber.
Supply, installation, testing & commissioning factory assembled and tested vertical pumpset with CI body and CI impeller, shaft of CI,CI suction and discharge and C.I. Base & head, mechanical seal, connected to a TEFC induction motor suitable for 400/440 volts, 3 phase 50 cycles A.C. supply with,isolation valve, non return valve of required sizes at discharge and suction of each pump, vibration eliminating pads as required, M.S channel fabricated common base plate bolted to cement concrete foundations complete.
Filter feed pumps:
Capacity : 2.0 Cum/hr.
Head : 30-35 Mtr
ONE set – ( 1 W + 1 S)
Motor HP = As per manufacturer recommendation
Make-Kirloskar/CRI
Treated Water Transfer pumps.
Capacity : 3.0 m3/hr
Head : 30-35 mtrs.
ONE set - ( 1 Working + 1 Standby)
Motor HP = As per manufacturer recommendation
Make-Kirloskar/CRI
Supply, installtiong, testing and commissioning of FRP vessel filter with frontal piping and associated valves and accessories. Filter shall be suitable for minimum working pressure of 3.5 kg / cm2 and shall include media, standard fittings like pressure gauges, sampling cock, rinse drain, vacuum breaker etc
Dual Media filter- Media Anthracite + Sand+ supporting media.
Flow rate : 2.5 Cum/hr
Filter Diameter : 600mm x 1800 mm HOS
Make-Oxybee solution/klenge system/Kunal enter prises
Activated Carbon Filter- Iodine value Graded Activated Carbon.
Flow Rate :2.5 Cum/hr
Filter Diameter : 600mm x 1800 mm HOS
Make-Oxybee/klengen
Supply, installation, testing and commissioning sludge handling system capable for 20 KLD STP, including filter press of Suitable Capacity with CI frame, PP plates complete with filter cloth complete with Filter press feed pump (Screw Type-1W+1S) – with interconnecting piping .
Make-Oxybee solution/klenge system/Kunal enter prises
Supply , Installation, Testing & Commissioning of Following metering devices:-
Outlet Treated water effluent Digital Flow meter
ELECTRICAL INSTALLATION FOR 20 KLD ETP
Constructing the following tanks & chambers in 4mm thick MS construction including the top cover as per as the approved calculation including 1mm FRP lining inside the tank and epoxy painting on out side of the approved colors and shades of emanel paint over a coat of primer .the plant should be of compact nature mounted on a common platform.The above cost shall include the cost of all required MS structure for skid plat form ,walking platform,hand rail ,staircase ,puddle flanges,foot rest,manhole cover etc with painting of desired shadeof enamel paint over a coat of primer.
Equalisation tank :- 8000 lit Civil (Client Scope )
Chemical reaction tank
Oxyprocessor tank ( Make -Oxybee solution /klengen system/Kunal enterprises)
Secondary settling tank ( Make -Oxybee solution /klengen system/Kunal enterprises)
Chlorine contact tank
Sludge holding tank (Syntex) ( Make -Oxybee solution /klengen system/Kunal enterprises)
All tanks are constructed in MSEP except bar screen,equalization tank and treated water tank
ULTRA FILTRATION PLANT
Providing, installation, testing & commissioning of fully automatic Ultra Filtration System (UF) of capacity 30 m3/hr. The system should be complete with Feed Pump (1W+1SB), Back Wash Pump (1W+1SB), Cartidge Filter, UF Membrane with Housing, Flushing/Cleaning System, complete instrumentation for automation and monitoring Rotameter, pressure guage, interconnecting pipe, vales/solenoid valve, PLC base electrical panel with cabling all complete with all accessories. UF Membraine: GE/DOW
RO SYSTEM
Supplying, lifting at the terrace, assembly, erection, testing and commissioning of RO Water treatment system including centalised water cooler for cold water proand all its components of required size as per water test analysis to make the water suitable for drinking, complete including the following as mentioned below. The cost will include testing of permeate water sample from a CPCB approved test laboratory, generating and providing membrane analysis data form the licensed manufacturer's software etc.
Permeate water quantity = 1000 lit/hr. and Permeate water quantity = 500 lit/hr.
Minimum Recovery = 70%-75%
Raw Water Characteristics - As per Water Test Analysis Report of Shriram Test Laboratory to be got done by the supplier
Raw water Quality
Turbidity : <1NTU
Chlorides : 205 ppm
Sulphates : 105 ppm
Treated Water Quality
Turbidity : <1NTU
Chlorides : < 10 ppm
Sulphates : < 5 ppm
TDS : < 50 ppm
SS Vertical centrifugal Raw Water Pump (1 Working + 1 Stand-by)
FRP Dual Media Filter
Activated Carbon Filter
Antiscalant Dosing System including pump chemical dosing pump, tanks etc.
Polypropylene Micron/cartridge Filter and SS housing
Stainless steel vertical multistage inline high pressure pump (1 Working) including dry running protection
Spirally wounded 6 nos. of RO Membranes
Composite FRP RO pressure tube/vessel
Automatic RO Module Cleaning System including chemical pump, cartridge filter, tanks etc.
pH correction system incl. chemical dosing pump, tanks etc.
Instrumentation including flow meters, digital TDS meter, digital pH meter, pressure gauges, low pressure switch, high pressure switch etc. complete.
SS-316L (8 kg/cm2) piping and ABS valves for low pressure and SS-316, schedule 10 piping and SS-316 L valves for high pressure piping in the plant.
Electrical panel including all starters, overload relays, single phase preventers, voltmeters, ammeters, MCB's, indicating lights, push buttons, rocker switches, incomers, auto-manual switches etc. complete.
All cabling , connections, terminations etc. required for the job.
Permeate water quantity =500 lit/hr. described above (a) to (m).
Supply Installation, Testing & Commissioning of water cooler having nominal cooling capacity of 150 liters per hours, with 150 litres storage tank with 3 nos. of faucets, one no goose neck type( for glass filling ) and other one fountain type (for drinking) both with separate mecahnical lever control with 4.5 HP electric motor for compressor to work on one phase 230 volts 50 Hz AC power supply with complete assessories including cutting and making wall as required.
Supply Installation, Testing & Commissioning of below counter installation type Drinking Water R.O. unit with micron filtration pre-treatment unit, skid mounted R.O. module with pressure pump and pressure tank, 6 m long food grade PP permeate line including connection to drinking water cooler, Coffee machine, complete in all respects.
Permeate 150 ltr/hr, Make Pentair/Fontus/Kent R.O.
ELECTRICAL WORKS
DISTRIBUTION CABLES & CABLE TRAY
Supply of following sizes of 1.1KV grade multicore Copper / aluminium conductor XLPE insulated and PVC sheathed armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant).
2 core, 6 sq.mm copper armoured cable
2 core, 10 sq.mm copper armoured cable
4 core, 6 sq.mm copper armoured cable
4 core, 10 sq.mm copper armoured cable
4 core, 16 sq.mm copper armoured cable
4 core 25 sq. mm
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required.
2 X 6 sq. mm (19mm) For copper armoured cable
4 X 6 sq. mm (25mm) For copper armoured cable
4 X 10 sq. mm (25mm) For copper armoured cable
4 X 16 sq. mm (28mm) For copper armoured cable
2 X 10 sq. mm (19mm) For copper armoured cable
Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS 15652-2006.
Supply, erection, testing and commissioning of following sizes of splitter of aluminium die cast body in suitable size of G.I. Box.
Supply, Installation, Testing & Commissioning of Earthing Junction Box size - 400mm x 300mm x 80mm made out of 16 SWG CRCA sheet with seven tank process & powder coating, earthing link (32mm x 6mm copper strip) front door with glass as complete as required.
Supply & installation of 32 Amp 3 phase, 415 volt, 50 Hz water tight (IP-55) socket outlet with interlocking switch complete with all fixing accessories.
Supply & installation of 32 Amp single phase 240 Volt, 50 Hz, water tight (IP-55) socket outlet with interlocking switch complete with all the fixing accessories as below.
Movement detectors (Infrared Type) Inbuilt ambient light sensor with adjustable lux level 5 to 600 lux, adjustable time delay from 1 minute to 15 minute, adjustable detection range 0 to 12 meter. The movement detector shall have lens, 360 deg and coverage area shall not be less than 48 sq. meter if height is 2.7 meter. The contact rating shall be suitable for 2000 watt light load.
Supply, Installation, Testing & Commissioning of 1P, 2 module surge protection device complete as required.
Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification.
100 mm wide x 40 mm deep.
150 mm wide x 40 mm deep.
200 mm wide x 40 mm deep.
250 mm wide x 40 mm deep.
300 mm wide x 40 mm deep.
Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification.
150 mm wide x 50 mm deep.
200 mm wide x 50 mm deep.
250 mm wide x 50 mm deep.
300 mm wide x 50 mm deep.
350 mm wide x 50 mm deep.
Supply & Laying of following sizes of 1.1KV grade multistranded copper conductor PVC insulated cable including termination complete as required in existing cable tray / existing conduit.
1C x 6 sq.mm PVC Insulated cu wire including termination etc.
1C x 10 sq.mm PVC Insulated cu wire including termination etc.
1C x 16 sq.mm PVC Insulated cu wire including termination etc.
1C x 25 sq.mm PVC Insulated cu wire including termination etc.
1C x 35 sq.mm PVC Insulated cu wire including termination etc.
1C x 50 sq.mm PVC Insulated cu wire including termination etc.
1C x 150 sq.mm PVC Insulated cu wire including termination etc.
Providing & painting of following Fire retardant paint 2 hour rating on XLPE insulated copper/ aluminium cable as per specifications.
DISTRIBUTION PANEL
RISING MAIN, TAPP OF BOXES AND END FEED UNIT-
END FEED UNIT-
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Installation, Testing & Commissioning of following End Feed Unit housing fabricated out of 14G CRCA powder coated (as approved) sheet steel for the Rising Mains fitted with following MCCB. The End Feed Unit should complete with solid aluminium links of rated capacity of MCCB to Rising Mains. The End Feed Unit should be complete with suitable size of glands plate for incoming cables. All MCCB shall have Ics value of 50 KA. Each end feed unit shall have a set of 3 nos. phase LED Type indicating lights with control fuses.
315 Amp, FP MCCB
400 Amp, FP MCCB
TAP OFF UNIT
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Installation, Testing & Commissioning of cubical type tap off unit box fabricated out of 1.6 mm thick CRCA sheet, dust and vermin proof, with hinged detachable doors and painted front, comprising LED type indication lamps with toggle switches and 4 pole MCCB terminated directly with tap off box with Bus Bar links on the incoming side and suitable for cable connection on the outgoing side including making connections, interconnections, earthing complete as required. All MCCB shall have Ics value of 36 KA and Thermal Magnetc release for over current & short circuit.
Tap Off Box with 63 Amp TP+N MCCB.
Tap Off Box with 100 Amp TP+N MCCB.
Tap Off Box with 125 Amp TP+N MCCB.
Tap Off Box with 160 Amp TP+N MCCB.
DISTRIBUTION PANEL
MAIN DG BACKUP PANEL (MEDICAL COLLEGE)
INCOMING
2 No. 1000 Amp FP Moulded Case Circuit Breaker
2 No. Digital Multi Function Meter with CT's.
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
1 Set of Mechanical interlocking between incommer & bus coupler.
BUS COUPLER
1 No. 1000 Amp FP Moulded Case Circuit Breaker
BUS BAR
1250 Amp TPN aluminium bus bar.
OUTGOING
01 No. 800 Amp FP Moulded Case Circuit Breaker
02 No. 500 Amp FP Moulded Case Circuit Breaker
06 No.160 Amp FP Moulded Case Circuit Breaker
11 No.100 Amp FP Moulded Case Circuit Breaker & & 8 No. KWH meter.
1 Lot of control / power wiring.
Panel described as above
MEDICAL EQUIPMENT PANEL-1 (MEDICAL COLLEGE)
INCOMING
01 No. 800 Amp FP Moulded Case Circuit Breaker
01 No. Digital Multi Function Meter with CT's.
01 Set of phase indicating lamps with Single Pole MCB.
01 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
1000 Amp TPN aluminium bus bar.
OUTGOING
04 No. 250 Amp FP Moulded Case Circuit Breaker
02 No. 160 Amp FP Moulded Case Circuit Breaker
08 No.100 Amp FP Moulded Case Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
MEDICAL EQUIPMENT PANEL-2 (MEDICAL COLLEGE)
INCOMING
01 No. 500 Amp FP Moulded Case Circuit Breaker
01 No. Digital Multi Function Meter with CT's.
01 Set of phase indicating lamps with Single Pole MCB.
01 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
630 Amp TPN aluminium bus bar.
OUTGOING
02 No. 160 Amp FP Moulded Case Circuit Breaker
07 No. 100 Amp FP Moulded Case Circuit Breaker
08 No.100 Amp FP Moulded Case Circuit Breaker
12 No.63 Amp FP Moulded Case Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
LIGHT PANEL-1,2,3 &4 (MEDICAL COLLEGE)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
300 Amp TPN aluminium bus bar.
OUTGOING
08 Nos 25 Amp TPN Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
POWER PANEL-1 (DG SUPPLY) (MEDICAL COLLEGE)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium bus bar.
OUTGOING
05 Nos40 Amp DP Miniature Circuit Breaker
06 Nos 25 Amp TPN Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
POWER PANEL-2 (DG SUPPLY) (MEDICAL COLLEGE)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium bus bar.
OUTGOING
07 Nos40 Amp DP Miniature Circuit Breaker
04 Nos 25 Amp TPN Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
AHU PANEL-1 (DG SUPPLY) (MEDICAL COLLEGE)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium bus bar.
OUTGOING
04 Nos 25 Amp TPN Miniature Circuit Breaker
05 Nos 40 Amp TPN Miniature Circuit Breaker
02 Nos 63 Amp TPN Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
AHU PANEL-2 (DG SUPPLY) (MEDICAL COLLEGE)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium bus bar.
OUTGOING
03 Nos 25 Amp TPN Miniature Circuit Breaker
06 Nos 40 Amp TPN Miniature Circuit Breaker
03 Nos 25 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
MAIN PANEL-2 (NORMAL SUPPLY) (MEDICAL COLLEGE)
INCOMING
1 No 400 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
500 Amp TPN aluminium bus bar.
OUTGOING
03 No250 Amp FP Moulded Case Circuit Breaker
01 No 200 Amp FP Moulded Case Circuit Breaker
03No 160 Amp FP Moulded Case Circuit Breaker
01 No 100 Amp FP Moulded Case Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
POWER PANEL-1 (NORMAL SUPPLY) (MEDICAL COLLEGE)
INCOMING
1 No 160 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
200 Amp TPN aluminium bus bar.
OUTGOING
08 Nos 63 Amp TPN Miniature Circuit Breaker
03Nos 25 Amp TPN Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
POWER PANEL-2 (NORMAL SUPPLY) (MEDICAL COLLEGE)
INCOMING
1 No 160 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
200 Amp TPN aluminium bus bar.
OUTGOING
11 Nos 63 Amp TPN Miniature Circuit Breaker
04 Nos 25 Amp TPN Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
POWER PANEL-3 & 4 (NORMAL SUPPLY) (MEDICAL COLLEGE)
INCOMING
1 No 250 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
300 Amp TPN aluminium bus bar.
OUTGOING
16 Nos 63 Amp TPN Miniature Circuit Breaker
03 Nos 25 Amp TPN Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
POWER PANEL-5 (NORMAL SUPPLY) (MEDICAL COLLEGE)
INCOMING
1 No 200 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
250 Amp TPN aluminium bus bar.
OUTGOING
15 Nos 63 Amp TPN Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
POWER PANEL-6 (NORMAL SUPPLY) (MEDICAL COLLEGE)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium bus bar.
OUTGOING
7 Nos 63 Amp TPN Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
UPS OUTGOING PANEL- (3 x60 KVA) (MEDICAL COLLEGE)
INCOMING
03 No. 160 Amp FP Moulded Case Circuit Breaker
03 Set of phase indicating lamps with Single Pole MCB.
03 Set of ON / OFF indicating lamps with Single Pole MCB.
03 No. Digital Multi Function Meter with CT's.
BUS BAR
400 Amp FP Copper bus bar.
OUTGOING
02 Nos 160 Amp FP Moulded Case Circuit Breaker
01 Nos 100 Amp FP Moulded Case Circuit Breaker
02 Nos 63 Amp FP Moulded Case Circuit Breaker
02 No. 25 Amp TPN Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
UPS PANEL-1 (MEDICAL COLLEGE)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium busbar.
OUTGOING
06 No. 25 Amp TPN Miniature Circuit Breaker
02 No. 40 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
UPS PANEL-2 (MEDICAL COLLEGE)
INCOMING
1 No 160 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
200 Amp TPN aluminium busbar.
OUTGOING
10 No. 25 Amp TPN Miniature Circuit Breaker
04 No. 40 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
EM. PANEL-1 (MEDICAL COLLEGE)
INCOMING
1 No 63 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
100 Amp TPN aluminium busbar.
OUTGOING
08 No. 25 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
EM. PANEL-2 (MEDICAL COLLEGE)
INCOMING
1 No 63 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
100 Amp TPN aluminium busbar.
OUTGOING
14 No. 25 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
LIFT PANEL-1&2 - TERRECE FLOOR (MEDICAL COLLEGE)
INCOMING
1 No 63 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium bus bar.
OUTGOING
03 Nos 63A FP RCBO.
05 Nos 40A TPN Miniature Circuit Breaker.
02 Nos 40A DP Miniature Circuit Breaker.
1 Lot of control / power wiring.
Panel described as above
KITCHEN (MEDICAL COLLEGE)
INCOMING
1 No 160 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
200 Amp TPN aluminium busbar.
OUTGOING
02 No 63 Amp FP Moulded Case Circuit Breaker
04 No. 63 Amp TPN Miniature Circuit Breaker
04 No. 40 Amp TPN Miniature Circuit Breaker
03 No. 63 Amp DP Miniature Circuit Breaker
02 No. 40 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
ELECTRICAL PANEL-1 (AUDI BLOCK)
INCOMING
1 No 300 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
400 Amp TPN aluminium busbar.
OUTGOING
02 No 125 Amp FP Moulded Case Circuit Breaker
01 No 100 Amp FP Moulded Case Circuit Breaker
03 No 63 Amp FP Moulded Case Circuit Breaker
08 No. 63 Amp TPN Miniature Circuit Breaker
04 No. 25Amp TPN Miniature Circuit Breaker & 3 nos. KWH meter
1 Lot of control / power wiring.
Panel described as above
HVAC PANEL-1 (AUDI BLOCK)
INCOMING
1 No 125 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium busbar.
OUTGOING
07 No. 63 Amp TPN Miniature Circuit Breaker
02 No. 40 Amp TPN Miniature Circuit Breaker
09 No. 25 Amp TPN Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
ELECTRICAL PANEL(STUDENT REC.)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium bus bar.
OUTGOING
02 Nos 63 Amp TPN Miniature Circuit Breaker
04 Nos 40 Amp TPN Miniature Circuit Breaker
02 Nos 40 Amp DP Miniature Circuit Breaker
01 Nos 25 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
UPS PANEL-1 (AUDI BLOCK)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium busbar.
OUTGOING
1 No 100 Amp FP Moulded Case Circuit Breaker
03 No. 25 Amp TPN Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
LIFT DB (AUDI BLOCK)
SCHEDULE ITEM
NON SCHEDULE ITEM
100 Amp TPN aluminium busbar.
OUTGOING
01 No 63 Amp FP RCBO..
01 No. 25 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
MAIN PANEL - 1 (D.G. BACKUP) (BOYS / GIRLS HOSTEL)
INCOMING
1 No. 300 Amp FP Moulded Case Circuit Breaker.
1 No. Digital Multifunction Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
400 Amp TPN aluminium busbar.
OUTGOING
01 Nos 160A FP Moulded Case Circuit Breaker with Digital KWH Meter.
04 Nos 100A FP Moulded Case Circuit Breaker.
10 Nos 25A TPN Miniature Circuit Breaker.
02 Nos 63A DP Miniature Circuit Breaker.
1 Lot of control / power wiring.
Panel described as above
ELECTRICAL PANEL -1 (D.G. BACKUP) (BOYS / GIRLS HOSTEL)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium busbar.
OUTGOING
09 No. 25 Amp TPN Miniature Circuit Breaker
02 No. 63 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
MAIN PANEL - 2 (NORMAL SUPPLY) (BOYS / GIRLS HOSTEL)
INCOMING
1 No 250 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
300 Amp TPN aluminium busbar.
OUTGOING
2 Nos. 160 Amp FP Moulded Case Circuit Breaker
2 Nos. 125 Amp FP Moulded Case Circuit Breaker
5 Nos. 63 Amp TPN Miniature Circuit Breaker
5 Nos. 25 Amp TPN Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
ELECTRICAL PANEL -1 (NORMAL SUPPLY) (BOYS / GIRLS HOSTEL)
INCOMING
1 No 160 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
200 Amp TPN aluminium busbar.
OUTGOING
2 Nos. 100 Amp FP Moulded Case Circuit Breaker
4 Nos. 63 Amp TPN Miniature Circuit Breaker
6 Nos. 25 Amp TPN Miniature Circuit Breaker
1 Nos. 63 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
ELECTRICAL PANEL -2 (NORMAL SUPPLY) (BOYS / GIRLS HOSTEL)
INCOMING
1 No 125 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium busbar.
OUTGOING
5 Nos. 63 Amp TPN Miniature Circuit Breaker
5 Nos. 25 Amp TPN Miniature Circuit Breaker
1 Nos. 63 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
ELECTRICAL PANEL -3 (NORMAL SUPPLY) (BOYS / GIRLS HOSTEL)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium busbar.
OUTGOING
5 Nos. 63 Amp TPN Miniature Circuit Breaker
5 Nos. 25 Amp TPN Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
LIFT PANEL-1 (BOYS / GIRLS HOSTEL, TYPE-III, TYPE-IV & TYPE-V))
INCOMING
1 No. 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium bus bar.
OUTGOING
03 No. 63 Amp FP RCBO.
01 No. 63 Amp TPN Miniature Circuit Breaker
05 No. 40 Amp TPN Miniature Circuit Breaker
02 No. 40 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
LIFT PANEL-2 (BOYS / GIRLS HOSTEL)
INCOMING
1 No. 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium bus bar.
OUTGOING
03 No. 63 Amp FP RCBO.
04 No. 40 Amp TPN Miniature Circuit Breaker
02 No. 40 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
UPS PANEL-
INCOMING
1 No. 63 Amp DP Miniature Circuit Breaker
BUS BAR
100 Amp DP aluminium bus bar.
OUTGOING
02 Nos 40 Amp DP Miniature Circuit Breaker.
01 Nos 25 Amp DP Miniature Circuit Breaker.
1 Lot of control / power wiring.
Panel described as above
ELECTRICAL PANEL (COMMUNITY CENTRE)
INCOMING
1 No 63 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
100 Amp TPN aluminium bus bar.
OUTGOING
02 Nos 40 Amp TPN Miniature Circuit Breaker
04 Nos 25 Amp TPN Miniature Circuit Breaker
01 Nos 25 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
ELECTRICAL PANEL- COMMON AREA (TYPE-III, IV & V)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
100 Amp TPN aluminium bus bar.
OUTGOING
02 No 100 Amp FP Moulded Case Circuit Breaker
02 Nos 63 Amp DP Miniature Circuit Breaker
01 Nos 25 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
METER BOARD (TYPE-III)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
100 Amp TPN aluminium bus bar.
OUTGOING
EACH OUTGOING FEEDER SHALL HAVE DUAL SOURCE ENERGY METER.
04 Nos 63 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
METER BOARD (TYPE-IV)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium bus bar.
OUTGOING
EACH OUTGOING FEEDER SHALL HAVE DUAL SOURCE ENERGY METER.
04 Nos 40 Amp FP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
METER BOARD (TYPE-V)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium bus bar.
OUTGOING
EACH OUTGOING FEEDER SHALL HAVE DUAL SOURCE ENERGY METER.
04 Nos 63 Amp FP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
ELECTRICAL PANEL- (TYPE- V)
INCOMING
1 No 250 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
300 Amp TPN aluminium bus bar.
OUTGOING
06 No 100 Amp FP Moulded Case Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
ELECTRICAL PANEL- (TYPE- VI)
INCOMING
1 No 80 Amp FP Moulded Case Circuit Breaker
BUS BAR
100 Amp TPN aluminium bus bar.
OUTGOING
02 Nos 63 Amp TPN Miniature Circuit Breaker
02 Nos 40 Amp TPN Miniature Circuit Breaker
01 Nos 40 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
ELECTRICAL PANEL-1 (GUEST HOUSE)
INCOMING
1 No 200 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
250 Amp TPN aluminium bus bar.
OUTGOING
04 No 100 Amp FP Moulded Case Circuit Breaker
03 Nos 63 Amp TPN Miniature Circuit Breaker
05 Nos 63 Amp DP Miniature Circuit Breaker with Dual source energy meter
1 Lot of control / power wiring.
Panel described as above
ELECTRICAL PANEL-2 (GUEST HOUSE)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium bus bar.
OUTGOING
04 No 63 Amp FP Moulded Case Circuit Breaker
02 Nos 63 Amp TPN Miniature Circuit Breaker
01 Nos 40 Amp TPN Miniature Circuit Breaker
01 Nos 25 Amp TPN Miniature Circuit Breaker
01 Nos 40 Amp DP Miniature Circuit Breaker
01 Nos 25 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
METER BOARD (GUEST HOUSE)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
150 Amp TPN aluminium bus bar.
OUTGOING
EACH OUTGOING FEEDER SHALL HAVE DUAL SOURCE ENERGY METER.
08 Nos 63 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
LIFT PANEL (GUEST HOUSE)
INCOMING
1 No 63 Amp FP Moulded Case Circuit Breaker
1 No. Digital Multi Function Meter with CT's.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
100 Amp TPN aluminium busbar.
OUTGOING
02 Nos. 63 Amp FP RCBO.
03 Nos. 40 Amp TPN Miniature Circuit Breaker
02 Nos. 40 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Panel described as above
MCCB BOXES
Supply, installation, testing & commissioning of MCCB in Sheet Steel enclosure made out of 2 mm thick CRCA sheet suitable for 3 phase 4 wire 50Hz AC system complete with four pole Moulded Case Circuit Breaker suitable for incoming & outgoing termination including power coating etc. complete as per specification & as required.
315 Amp FP MCCB
250 Amp FP MCCB
100 Amp FP MCCB
63 Amp FP MCCB
200 Amp FP MCCB
160 Amp FP MCCB
40 Amp DP MCB
ELE MAIN PANEL-1 -DG BACKUP (NEW BLOCK)
INCOMING
02 No. 630 Amp FP Moulded Case Circuit Breaker.
02 Set of phase indicating lamps with Protective SP MCB.
02 Set of ON / OFF indicating lamps with Protective SP MCB.
02 Set of Electronic KWH Meter with maximum demand recording facility.
BUS COUPLER
1 No. 500 Amp FP Moulded Case Circuit Breaker
BUS BAR
700 Amp TPN aluminium bus bar.
OUTGOING
01 No. 500 Amp TP+N Moulded Case Circuit Breaker.
02 No.200 Amp TP+N Moulded Case Circuit Breaker.
08 No.100 Amp TP+N Moulded Case Circuit Breaker.
06 No.63 Amp TP+N Moulded Case Circuit Breaker.
07 No. 63 Amp TPN Miniature Circuit Breaker.
Panel described as above
LIFT PANEL-1 (NEW BLOCK)
INCOMING
01 No. 100 Amp FP Moulded Case Circuit Breaker.
01 Set of phase indicating lamps with Protective SP MCB.
01 Set of ON / OFF indicating lamps with Protective SP MCB.
BUS BARS
150 Amp TPN aluminium busbar.
OUTGOING
04 No.63 Amp TP+N Moulded Case Circuit Breaker.
05 No. 40 Amp TPN Miniature Circuit Breaker.
01 No. 40 Amp DP Miniature Circuit Breaker.
Panel described as above
LIGHT PANEL-1 (NEW BLOCK)
INCOMING
01 No. 200 Amp FP Moulded Case Circuit Breaker.
01 Set of phase indicating lamps with Protective SP MCB.
01 Set of ON / OFF indicating lamps with Protective SP MCB.
BUS BARS
250 Amp TPN aluminium busbar.
OUTGOING
04 No. 40 Amp TPN Miniature Circuit Breaker.
09 No. 25 Amp TPN Miniature Circuit Breaker.
Panel described as above
POWER PANEL-1 WITHOUT DG BACKUP (NEW BLOCK)
INCOMING
01 No. 500 Amp FP Moulded Case Circuit Breaker.
01 Set of phase indicating lamps with Protective SP MCB.
01 Set of ON / OFF indicating lamps with Protective SP MCB.
01 Set of Electronic KWH Meter with maximum demand recording facility.
BUS BARS
600 Amp TPN aluminium busbar.
OUTGOING
01 No. 100 Amp TP+N Moulded Case Circuit Breaker.
18 No. 63 Amp TPN Miniature Circuit Breaker.
Panel described as above
POWER PANEL-2 WITHOUT DG BACKUP (NEW BLOCK)
INCOMING
01 No. 500 Amp FP Moulded Case Circuit Breaker.
01 Set of phase indicating lamps with Protective SP MCB.
01 Set of ON / OFF indicating lamps with Protective SP MCB.
01 Set of Electronic KWH Meter with maximum demand recording facility.
BUS BARS
600 Amp TPN aluminium busbar.
OUTGOING
29 No. 63 Amp TPN Miniature Circuit Breaker.
Panel described as above
AHU PANEL- (NEW BLOCK)
INCOMING
01 No. 500 Amp FP Moulded Case Circuit Breaker.
01 Set of phase indicating lamps with Protective SP MCB.
01 Set of ON / OFF indicating lamps with Protective SP MCB.
BUS BARS
600 Amp TPN aluminium busbar.
OUTGOING
02 No. 160 Amp TP+N Moulded Case Circuit Breaker.
01 No. 100 Amp TP+N Moulded Case Circuit Breaker.
15 No. 63 Amp TPN Miniature Circuit Breaker.
02 No. 40 Amp TPN Miniature Circuit Breaker.
06 No.25 Amp TPN Miniature Circuit Breaker.
Panel described as above
VENTILATION PANEL- (NEW BLOCK)
INCOMING
01 No. 200Amp FP Moulded Case Circuit Breaker.
01 Set of phase indicating lamps with Protective SP MCB.
01 Set of ON / OFF indicating lamps with Protective SP MCB.
BUS BARS
150 Amp TPN aluminium busbar.
OUTGOING
22 No. 25 Amp TPN Miniature Circuit Breaker.
Panel described as above
EMERGENCY LIGHT PANEL (NEW BLOCK)
INCOMING
01 No. 63Amp FP Moulded Case Circuit Breaker.
01 Set of phase indicating lamps with Protective SP MCB.
01 Set of ON / OFF indicating lamps with Protective SP MCB.
BUS BARS
100 Amp TPN aluminium busbar.
OUTGOING
13 No. 25 Amp DP Miniature Circuit Breaker.
Panel described as above
UPS PANEL-1- (NEW BLOCK)
INCOMING
03 No. 100Amp FP Moulded Case Circuit Breaker.
03 Set of phase indicating lamps with Protective SP MCB.
03 Set of ON / OFF indicating lamps with Protective SP MCB.
BUS BARS
300 Amp TPN aluminium busbar.
OUTGOING
01 No. 63Amp TP+N Moulded Case Circuit Breaker.
04 No. 63 Amp TPN Miniature Circuit Breaker.
04 No. 25 Amp TPN Miniature Circuit Breaker.
05 No. 63 Amp DP Miniature Circuit Breaker.
05 No. 40 Amp DP Miniature Circuit Breaker.
Panel described as above
LIFT DB- (NEW BLOCK, EXISTING BLOCK, & CSSD BLOCK)
INCOMING/OUTGOING
01 No. 63Amp FP RCBO.
01 No. 20 Amp DP Miniature Circuit Breaker.
01 No. 10 Amp DP Miniature Circuit Breaker.
Panel described as above
3X15 KVA UPS PANEL (NEW BLOCK)
INCOMING
03 No. 63Amp FP Moulded Case Circuit Breaker.
03 Set of phase indicating lamps with Protective SP MCB.
03 Set of ON / OFF indicating lamps with Protective SP MCB.
BUS BARS
200 Amp TPN aluminium busbar.
OUTGOING
03 No. 63AmpTP+N Moulded Case Circuit Breaker.
Panel described as above
UPS PANEL (EXISTING BUILDING-G+2)
INCOMING
02 No. 100Amp FP Moulded Case Circuit Breaker.
02 Set of phase indicating lamps with Protective SP MCB.
02 Set of ON / OFF indicating lamps with Protective SP MCB.
BUS BARS
250 Amp TPN aluminium busbar.
OUTGOING
02 No. 63 Amp TPN Miniature Circuit Breaker.
08 No.25 Amp TPN Miniature Circuit Breaker.
04 No. 40 Amp DP Miniature Circuit Breaker.
02 No. 25 Amp DP Miniature Circuit Breaker.
Panel described as above
2X15 KVA UPS PANEL (EXISTING BLOCK 2ND FL)
INCOMING
02 No. 63Amp FP Moulded Case Circuit Breaker.
02 Set of phase indicating lamps with Protective SP MCB.
02 Set of ON / OFF indicating lamps with Protective SP MCB.
BUS BARS
150 Amp TPN aluminium busbar.
OUTGOING
02 No. 63AmpTP+N Moulded Case Circuit Breaker.
Panel described as above
ELECTRICAL PANEL-1-DG BACKUP (EXISTING BLOCK 2ND FL)
INCOMING
01 No. 200Amp FP Moulded Case Circuit Breaker.
01 Set of phase indicating lamps with Protective SP MCB.
01 Set of ON / OFF indicating lamps with Protective SP MCB.
01 Set of Electronic KWH Meter with maximum demand recording facility.
BUS BARS
250 Amp TPN aluminium busbar.
OUTGOING
03 No.100Amp TP+N Moulded Case Circuit Breaker.
03 No.63Amp TP+N Moulded Case Circuit Breaker.
01 No. 40 Amp TPN Miniature Circuit Breaker.
06 No. 25 Amp TPN Miniature Circuit Breaker.
Panel described as above
ELE PANEL-2-WITHOUT DG BACKUP (EXISTING BLOCK 2ND FL)
INCOMING
01 No. 200Amp FP Moulded Case Circuit Breaker.
01 Set of phase indicating lamps with Protective SP MCB.
01 Set of ON / OFF indicating lamps with Protective SP MCB.
01 Set of Electronic KWH Meter with maximum demand recording facility.
BUS BARS
250 Amp TPN aluminium busbar.
OUTGOING
15 No. 63 Amp TPN Miniature Circuit Breaker.
Panel described as above
ELE PANEL-2-WITHOUT DG BACKUP (EXISTING BLOCK G+1)
INCOMING
01 No. 250Amp FP Moulded Case Circuit Breaker.
01 Set of phase indicating lamps with Protective SP MCB.
01 Set of ON / OFF indicating lamps with Protective SP MCB.
01 Set of Electronic KWH Meter with maximum demand recording facility.
BUS BARS
300 Amp TPN aluminium busbar.
OUTGOING
0 No.63 Amp TPN Miniature Circuit Breaker.
Panel described as above
ELE PANEL-1- DG BACKUP (EXISTING BLOCK G+1)
INCOMING
01 No. 400 Amp FP Moulded Case Circuit Breaker.
01 Set of phase indicating lamps with Protective SP MCB.
01 Set of ON / OFF indicating lamps with Protective SP MCB.
01 Set of Electronic KWH Meter with maximum demand recording facility.
BUS BARS
500 Amp TPN aluminium busbar.
OUTGOING
01 No.250Amp TP+N Moulded Case Circuit Breaker.
04 No.100Amp TP+N Moulded Case Circuit Breaker.
03 No. 63 Amp TPN Miniature Circuit Breaker.
04 No. 25 Amp TPN Miniature Circuit Breaker.
Panel described as above
ELECTRICAL PANEL-1 (CSSD & LAUNDRY BLOCK G+1)
INCOMING
01 No. 63 Amp FP Moulded Case Circuit Breaker.
01 Set of phase indicating lamps with Protective SP MCB.
01 Set of ON / OFF indicating lamps with Protective SP MCB.
BUS BARS
100 Amp TPN aluminium busbar.
OUTGOING
01 No. 63 Amp TP+N Moulded Case Circuit Breaker.
02 No. 40 Amp TPN Miniature Circuit Breaker.
02 No. 40 Amp DP Miniature Circuit Breaker.
Panel described as above
CSSD PANEL
INCOMING
01 No. 250 Amp FP Moulded Case Circuit Breaker.
01 Set of phase indicating lamps with Protective SP MCB.
01 Set of ON / OFF indicating lamps with Protective SP MCB.
01 Set of Electronic KWH Meter with maximum demand recording facility.
BUS BARS
300 Amp TPN aluminium busbar.
OUTGOING
02 No. 100 Amp TP+N Moulded Case Circuit Breaker.
05 No.63 Amp TPN Miniature Circuit Breaker.
04 No.40 Amp TPN Miniature Circuit Breaker.
01 No.25 Amp TPN Miniature Circuit Breaker.
Panel described as above
LAUNDRY PANEL
INCOMING
01 No. 100 Amp FP Moulded Case Circuit Breaker.
01 Set of phase indicating lamps with Protective SP MCB.
01 Set of ON / OFF indicating lamps with Protective SP MCB.
01 Set of Electronic KWH Meter with maximum demand recording facility.
BUS BARS
150 Amp TPN aluminium busbar.
OUTGOING
02 No. 63 Amp TPN Miniature Circuit Breaker.
02 No. 40 Amp TPN Miniature Circuit Breaker.
02 No.25 Amp TPN Miniature Circuit Breaker.
02 No.40 Amp DP Miniature Circuit Breaker.
Panel described as above
MCCB BOXES
Supply, installation, testing & commissioning of MCCB in Sheet Steel enclosure made out of 2 mm thick CRCA sheet suitable for 3 phase 4 wire 50Hz AC system complete with four pole Moulded Case Circuit Breaker suitable for incoming & outgoing termination including power coating etc. complete as per specification & as required.
250 Amp FP MCCB
100 Amp FP MCCB
63 Amp FP MCCB
40 Amp DP MCB
SUPPLY & FIXING OF LIGHT FIXTURES & FANS INTERNAL LIGHTING-
Supply, Installation, Testing & Commissioning of 1x38 Watt LED Light Fixture surface mounted philips make cat no- BN108C LED 40S PSU NW WH or equivalent.
Supply, Installation, Testing & Commissioning of 1x12 LED lamp suitable for batten holder. (Siska Make or equivalent.)
Supply, Installation, Testing & Commissioning of LED Bulk Head Light Fixture surface mounted Philips make cat no- WT202W LED6S NW PSU S2 PC or equivalent.
Supply, Installation, Testing & Commissioning of 1x9 watt LED Mirror light fixture wall mounted with electronic high efficiency electronic driver as complete as required. (Philips Make, Cat No- 31083 shell line or equivalent).
Supply, Installation, Testing & commissioning of 1x23 watt bracket light. ((Philips Make, Cat No- QWG311 or equivalent).
Supply of following sizes of heavy duty exhaust fan for single phase 230 volt, 50HZ AC supply complete with motor, blades, frame, bracket, louver/ shutter etc as required. (HavellS Make, Cat No - Ventil Air-DX WHT/BLK or equivalent).
250 mm Exhaust Fan
Supply, Installation, Connecting, Testing and Commissioing of Fire Exit Sign as omniex model ( illuminated) made from etched Acrylic Sheet of 8 mm thickness, with LED string illumination including all fittings / fixtures and electrical accessories, power supply with Battery Charger & Battery backup etc. complete as required.
Supply, Installation, Testing & Commissioning of LED 46W Light recess mounted downlight with high efficiency electronic driver. (Make Philips Cat No- RS271B LED40/830 PSU-E WB WH or equivalent.)
Supply, Installation, Testing & Commissioning of 3400 lumen / 34 to 40 watt LED Light recess mounted downlight with high efficiency electronic driver. (Make Philips Cat No RC380B LED34S-4000 L60W60 PSU OD S1 or equivalent.)
Supply, Installation, Testing & Commissioning of LED Step Light 15 watt, Philips make, cat No-BWG150 LED50/WWPSU 220-240V IP67 7043 or equivalent.
Supply, Installation, Testing & Commissioning of Cleanroom 1x33 Watt LED Light, Philips make, cat No-CR652B LED33S CR NW CA or equivalent.
Supply, Installation, Testing & Commissioning of Chandilier Light, Philips make, Cat No-45618/17 Bowl or equivalent.
Supply, Installation, Testing & Commissioning of 4 watt per meter (300 lumen per meter) LED cove Light with high efficiency electronic driver. (Make Philips Cat No- LS150S LED3/WW L5000 IN or equivalent.)
Supply, Installation, Testing & Commissioning of 2W Steplight suitable for recessed mounting made up of Aluminum Base in Anthracite color must hav LED Life of 50K burning Hrs (Make:- Philips CAT No.- 34151 Recessed Step Light) for ramp
Supplying, Installation, Testing & Commissioning of Self contained emergency light units 1x9 watt double sided for wall / ceiling mounting with suspension / mounting kit, lamps, inbuilt standby battery (for 2 hours backup) and battery charger etc. in suitable enclosure. Make - Prolite or equivalent.
Supply, Installation, Testing & Commissioning of 2x18W /40 W LED Tube Light Fixture surface mounted philips make cat no- TMC 100 2X18W LED LAMP or equivalent.
CONDUITING & WIRING FOR COMPUTER NETWORKING
Supply and fixing of telephone distribution board (tag blocks) in hinged type MS box duly powder coated complete with bakelite sheet with termination of incoming and outgoing telephone wire etc. complete as required.
10 pair telephone distribution board.
50 pair telephone distribution board.
100 pair telephone distribution board.
200 pair telephone distribution board.
500 pair telephone distribution board.
20 pair telephone distribution board.
Supply and wiring of telephone cable 0.61mm dia annealed tinned copper conductor PVC insulated and PVC sheathed unarmoured telephone cable in existing conduit in concealed/ surface system / existing cable tray complete as required.
5 pair telephone unarmoured cable.
10 pair telephone unarmoured cable.
20 pair telephone unarmoured cable.
50 pair telephone unarmoured cable.
100 pair telephone unarmoured cable.
Supply, Installation, Testing & Commissioning of the Cats 6 information outlets that should confirm or exceed component specifications TIA/EIA-568-B.2-1 standards for physical & electrical Specifications, should be fully unshielded type and should have the tool less mechanism with inbuilt crimping tool and it should be Third Party certified and tested. (RJ-45).
CONDUITING & WIRING FOR TELEPHONE & COMPUTER NETWORKING
FIRE ALARM SYSTEM (ADDRESSABLE TYPE) & PA SYSTEM-
FIRE ALARM
Supply, Installation, Testing & Commissioning of EN-54 Compliant, Vds & FM approved, 12-Loop, Intelligent, Analog Adressable, Networkable FACP (Fire Alarm Control Panel) with mounting bracket and required installation accessories. Each detection loop of the FACP shall have a capacity of 126 devices in any combination. The FACP shall have 4/6/8 lines x 40 characters display and built in Degrade Mode function. The FACP shall have networking capability up to min 64 nodes and min 2000 event memory. The FACP shall have power supply of min 150W with battery charging capacity up to 65AH. The FACP shall provide Bacnet over IP for 3rd party integration. The FACP shall have min IP30 protection.
12 Loops
2 Loops
1 Loops
5 Loops
4 Loops
Supply, Installation, Testing & Commissioning of EN-54 Compliant, Vds & FM approved, Active Repeater Panel / Remote Terminal with mounting bracket and required installation accessories. The remote terminal shall facilitate monitoring & control of fire events from pre-decided strategic location away from the main FACP. The remote terminal shall facilitate monitoring and control of fire events for each and every device connected to the FACP. It shall have 6 lines x 40 characters display.
Supply, Installation, Testing & Commissioning of PC based Graphical User Interface. The quotation shall include specified PC, Printer, Software, Licenses, necessary hardware & accessories to map all the Control Panels, Nodes in the network and connected devices. The GUI shall facilitate password-protected, user access level defined monitoring and control of each node and each connected device in the network.
Supply, Installation, Testing & Commissioning of EN-54 Compliant, Vds & FM approved, Intelligent Addressable Advance Signal Analysis Multi-Criteria Detector with inbuilt Isolator. The detector shall be quoted with Base, required junction box and installation accessories. The detector shall take alarm decison with Advance Signal Analysis based on Backward & Forward light scattering principle. The detector shall be configured as Multi-Sensor, Smoke Detector, Fixed Heat Detector or ROR Heat Detector or combination of all from configuration tool.
Supply, Installation, Testing & Commissioning of EN-54 Compliant, Vds & FM approved, Intelligent Addressable Duct Detector with Base, Duct Housing, Tube, required junction box and installation accessories.
Supply, Installation, Testing & Commissioning of EN-54 Compliant, Vds & FM approved, addressable Manual Call Point with inbuilt Isolator & Break Glass. The MCP shall have Test-Key to activate without removing glass for performance check. The MCP shall be quoted with required junction box and mounting accessories.
Supply, Installation, Testing & Commissioning of EN-54 Compliant, Vds & FM approved, addressable Monitor Module with inbuilt Isolator. The monitor module shall have LED indication for Normal, Fault, Test & Alarm activation. The Monitor Module shall be quoted with required junction box and mounting accessories. The module shall have IP40 protection.
Supply, Installation, Testing & Commissioning of EN-54 Compliant, Vds & FM approved, addressable Output Module with inbuilt Isolator. The module shall have LED indication for Normal, Fault, Test & Alarm activation. The Module shall be quoted with required junction box and mounting accessories. The module shall have IP40 protection.
Supply, Installation, Testing & Commissioning of EN-54 Compliant, Vds & FM approved, Addressable, Loop Powered Strobe with inbuilt Isolator. The Strobe shall be independently programmable. The strobe shall be quoted with required junction box and mounting accessories.
Supply, installation, testing and commissioning of 32 lines full duplex Fire Fighter's talk Back system with operator command centre and sufficient no. of point. The full duplex emergency communication system shall be able to display customized address of the location from which the Call is being made to the Fire Fighter's command Centre.
Supply, installation, testing and commissioning of 2 way communication addressable Fire Fighter's Telephone Jack Complete as required as per technical specification.
Supply, installation, testing and commissioning of 2 way communication Fire Fighter's field Handset Complete with MS Enclosure with front Glass facia as required as per technical specification.
Supply Installation, Testing & Commissioning of Intelligent addressable photothermal detector with blue colour LED for very early warning with inbuilt isolator as per NFPA7 style 7 wiring & standard base complete as per specification.
Supply, Installation, Testing & Commisioning of Analogue Addressable Intelligent Heat Detector with fixed & rate of rise temperature function with decentralise intelligence , soft addressable type, with inbuilt fault isolator as per NFPA style 7 wiring complete with base as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface / recessed including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
PUBLIC ADDRESS SYSTEM
Supply, Installation, Testing and Commissioning of IP based Digital Controller, UL certified, IP based Digital audio controller with built-in 24 bit A/D and D/A converters and parametric equalizer capable of handling 8 loudspeaker lines, Automatic Gain Control, Feedback killers, Automatic Microphone mixers and Crossovers, Automatic Noise sensing With the 100 Mbyte memory, the following storage times should be available with WAV format, 36 minutes of audio message at 48 kHz-8 bits, 18 minutes of audio message at 48 kHz, 16 bits, 8 controls Inputs and 8 TTL Outputs for remote control and monitoring, Simultaneous 6 Channel Music Playback ability in single controller.
Supply, Installation, Testing & Commissioning of 8 Zone Digtal PA Slave Processor with fully Digital Audio system for Public Address and Evacuation consisting of audio digital signal processing (DSP), a matrix, a digital message player, a fully monitored fireman microphone, amplifiers monitoring with switchover to backup amplifier and loudspeaker lines monitoring. 8 zone 1000W.
Supply, Installation, Testing & Commissioning of 1000W Audio Digital Power Amplifier with Short-circuit protection, thermal protection, Supply input AC 230/240V-50Hz and as per complete technical specification.
Supply, Installation, Testing & Commissioning of 480W Audio Digital Power Amplifier with Short-circuit protection, thermal protection, Supply input AC 230/240V-50Hz and as per complete technical specification.
Supply, Installation, Testing and Commissioning of Touch Screen Call Station with Zoning and Paging Microphone, 5” TFT full color paging console, 3 LED indicators: Power/General Fault/Evacuation active, Ethernet: CAT5 connection, 3 key-buttons: User definable using Studio GUI, 168 Touch fields: 14 pages with 12 keys, Console size: (L x W x D) 250 x 140 x 80 mm, Microphone flex length: 280 mm, Color: RAL 7016, Front tilted at 30°, Material: metal back, PVC top and sides.
Supply, Installation, Testing and Commissioning of 6/3 Watt Ceiling Mounted Speaker with frequency response of 85Hz-20KHz capable of a Max SPL of 95dB with Line matching transformer, complete with mounting accessories as required.
Supply, Installation, Testing and Commissioning of 19" MS Rack Suitable to house the above required equipments, With Glass Door, Side Openable, Cooling arrangement, Wheels and brakes and as per technical specification.
Supply, Installation, Testing and Commissioning of 6/3 Watt Wall Mounted Speaker / Ceiling surface mounted speaker with back box with frequency response of 85Hz-20KHz capable of a Max SPL of 95dB with Line matching transformer, complete with mounting accessories as required.
Supply, Installation, Testing and Commissioning of 12 Watt volume controller with G.I. Box, modular plate etc as complete as required.
Wiring for PA system with the following sizes of PVC insulated copper conductor twisted cables in existing surface/recessed M.S. conduit etc. as complete as required.
2 x 1.5 sq.mm twin twisted PVC copper wire
Supply, Installation, Testing and Commissioning of 42" MS Rack Suitable to house the above required equipments, With Glass Door, Side Openable, Cooling arrangement, Wheels and brakes and as per technical specification.
SITC of 1x250W Class-D Amplifier with 4 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection Approved Makes : Bosch Praesedio / Honeywell - X618/ Ateis - IDA
Supplying and fixing of following sizes of steel conduit along with accessories in surface / recessed including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
UPS SYSTEM
Supply, installation, testing & commissioing of 60 KVA UPS in paralleling mode at 0.99 input power factor with SNMP card with inbilt isolation transformer as per specification given in the document with following broad features.
THD(i) shall be less than 3% in the entire loading range.
Input power factor shall be more than 0.95. from 25% to 100% load.
UPS shall carry design output at 40 deg.
Shall have soft start and hold of for incoming supply.
Invertor capability to supply 150% load for 5 sec.
Three Phase Input and Three Phase Output. (Input - 340V - 470V, Three Phase, 4 wire. / Output - 400-415 Volt, Three Phase, 4 Wire.)
Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.
Battery shall be external type with rack and suitable for 30 minute backup on 100% load.
UPS shall be compatible for minimum 3 nos unit in parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS.
UPS described as above
Supply, installation, testing & commissioing of 40 KVA UPS in paralleling mode at 0.99 input power factor from 25% to 100% load with SNMP card with inbilt isolation transformer before static switch as per specification given in the document with following broad features.
THD(i) shall be less than 3%.
Input power factor shall be more than 0.99. from 25% to 100% load.
UPS shall carry design output at 40 deg.
Shall have soft start and hold of for incoming supply.
Invertor capability to supply 150% load for 1 minute.
Three Phase Input and Three Phase Output. (Input - 340V - 470V, Three Phase, 4 wire. / Output - 400-415 Volt, Three Phase, 4 Wire.)
Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.
Battery shall be external type with rack and suitable for 20 minute backup on 100% load.
Suitable Size of Cables between battery bank and UPS and battery breaker with fuse protection.
UPS shall be compatible for minimum 3 nos unit in parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS.
Input phase sequence correction to be builtin in the system.
UPS described as above
Supply, installation, testing & commissioing of 7.5 KVA UPS as per specification given in the document with following broad features.
THD(i) shall be less than 3% in the entire loading range.
Input power factor shall be more than 0.95. from 25% to 100% load.
UPS shall carry design output at 40 deg.
Shall have soft start and hold of for incoming supply.
Invertor capability to supply 150% load for 5 sec.
Single Phase Input and Single Phase Output. (Input - 220V - 260V, Single Phase, 2 wire. / Output - 220 Volt, Single Phase, 2 Wire.)
Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.
Battery shall be external type with rack and suitable for 30 minute backup on 100% load.
UPS described as above
Supply, installation, testing & commissioing of 1.5 KVA UPS as per specification given in the document with following broad features.
THD(i) shall be less than 3% in the entire loading range.
Input power factor shall be more than 0.95. from 25% to 100% load.
UPS shall carry design output at 40 deg.
Shall have soft start and hold of for incoming supply.
Invertor capability to supply 150% load for 5 sec.
Single Phase Input and Single Phase Output. (Input - 220V - 260V, Single Phase, 2 wire. / Output - 220 Volt, Single Phase, 2 Wire.)
Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.
Battery shall be suitable for 30 minute backup on 100% load.
UPS described as above
Supply installation , testing & Commissioning of following rating of invertor with battery and trolley as complete as required. Invertor shall be suitable for 90 minute backup on full load as per spercification. (For Substation, HVAC, Plumbing Plant Room)
1000 VA, 220 Volt
Supply, installation, testing & commissioing of 40 KVA UPS in paralleling mode at 0.99 input power factor with inbuilt / external isolation transformer as per specification given in the document with following broad features.
THD(i) shall be less than 5% in the entire loading range.
UPS shall carry design output at 40 deg.
Shall have soft start and hold of for incoming supply.
Invertor capability to supply 150% load for 5 sec.
Three Phase Input and Three Phase Output. (Input - 340V - 470V, Three Phase, 4 wire. / Output - 400-415 Volt, Three Phase, 4 Wire.)
Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.
Battery shall be external type with rack and suitable for 15 minute backup on 100% load.
UPS shall be compatible for parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS.
UPS described as above
Supply installation , testing & Commissioning of following rating of invertor with battery and trolley as complete as required. Invertor shall be suitable for 90 minute backup on full load as per spercification. (For Substation, HVAC, Plumbing Plant Room)
2000 VA, 220 Volt
1000 VA, 220 Volt
SUBSTATION EQUIPMENTS
HT PANEL
33KV H.T. METERING PANEL (INDOOR TYPE):
Supply, Receiving, Unloading, Storing, Shifting, Installation, Testing & Commissioning of indoor type floor mounted, dust, damp and vermin proof, cubicle HT. Metering Panel made out of 14 gauge CRCA sheet steel complete with 5Amp electronic trivector meter, C.T.'s of 150/5Amp, 0.5 Class, 10VA Burden, and P.T's of 33KV/ /3, 110V/ /3, 100 VA conforming to relevant IS Standards and complete as required. H.T. Metering cubicle along with C.T.'s, P.T.'s and trivector meter shall be got tested and approved from local electricity supply authority. The GA drawing shall be got approved by ELECTRICITY BOARD authorities before fabrication.
33 KV HT VCB THREE BREAKER PANEL BOARD (INDOOR TYPE) (1 INCOMMING + 2 OUTGOING) - EXPADABLE TYPE
Supply, Receiving, Unloading, Shifting, Installation Testing & Commissioning of 33 KV, expandable type three Breaker Vacuum Circuit Breaker Panel Board as 1 Incomming & 2 Outgoing shall be metal clad floor mounting complete as per specification and as described.
630 A Vacuum circuit breaker of (1000 MVA) 26.3 KA RMS for 3 second ruputuring capacity for at 33 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation, vermin proof, fully interlocked horizontal drawout type having isolation features and control devices complete with the following.
Manually and motor operated, spring charged (release closing mechanism) trip free type,triple pole truck mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indication"OFF" push buttons for emergency trip (shrouded) test/service position limit switches with 6 NO/6 NC breaker auxilliary contacts in service position, 24 Volts DC shunt trip coil and strip heater to prevent moisture absorption.
INCOMING PANEL - 1 NO.
630 A Vacuum circuit breaker of (1000 MVA) 26.3 KA RMS for 3 second ruputuring capacity for at 33 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation, vermin proof, fully interlocked horizontal drawout type having isolation features and control devices complete with the following.
3 No. Single Phase double core current transformer 150/5 Amp epoxy cast insulated class of insulation E.
Core 1-15VA burden class 1.0 for metering.
Core 2-15VA burden class 5P10 for protection.
P.T's of 33KV/1.732, 110V/1.732, 100VA with suitable rating H.T. & L.T. fuse conforming to relevant IS Standards and complete as required.
One no. numerical microprocessor based three phase over current (IDMT element) (2 O/C+1E/F) with earth fault relay with instantaneous elements.
1 No. Anti Pumping device.
1 No. Circuit breaker control switch for electrical (T/N/C).
1 No. Limit Switch for test & service position.
1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
1 Set of following indicating lamps.
Red, Yellow & Blue for phase indication.
Amber for Trip indication.
Red `ON' Green `OFF'
Spring charge indication.
Auto trip indication.
1 No. hooter with hooter acceptance and reset push button.
1 No. master trip relay. ( Electromechanical Type )
1 No.Trip ckt supervision relay. (Electromechanical Type )
600A color coded heat shrinkable sleeved TP Copper busbar of 350 MVA fault rating.
1 Set of fuses, ferrules, wiring etc. as required.
1 Set of Power Pack 220 Volt A.C. / 24 Volt D.C. complete as required.
Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate ferrules / coding. The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm subjected to providing minimum size strip suitable for 4/6sqmm.
OUTGOING PANEL - 2 NO. (Each outgoing feeder shall have following)
630 A Vacuum circuit breaker of (1000 MVA) 26.3 KA RMS for 3 second ruputuring capacity for at 33 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation, vermin proof, fully interlocked horizontal drawout type having isolation features and control devices complete with the following.
3 No. Single Phase double core current transformer 50/5 Amp epoxy cast insulated class of insulation E.
Core 1-15VA burden class 1.0 for metering.
Core 2-15VA burden class 5P10 for protection.
One no. numerical microprocessor based three phase over current (IDMT element) (2 O/C+1E/F) with earth fault relay with instantaneous elements.
1 No. Anti Pumping device.
1 No. Circuit breaker control switch for electrical (T/N/C).
1 No. limit switch for test & service position.
1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
1 Set of following indicating lamps.
Red, Yellow & Blue for phase indication.
Amber for Trip indication.
Red `ON' Green `OFF'
Spring charge indication.
Auto trip indication.
1 No. hooter with hooter acceptance and reset push button.
1 No. master trip relay. ( Electromechanical Type)
1 No.Trip ckt supervision relay (Electromechanical Type)
1 Set of fuses, ferrules, wiring etc. as required.
4 No. VAA33 auxiliary relay for transformer fault, alarm and trip.
12 Annunciator window for all electrical and transformer fault.
Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate ferrules / coding. The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm subjected to providing minimum size strip suitable for 4/6sqmm.
a. The above panel shall be expandable type.
c. Quoted price shall also included with extention link if it required.
H.T. Panel describe as above
33 KV HT VCB SINGLE BREAKER PANEL (INDOOR TYPE) (INCOMMING /OUTGOING)
Supply, Receiving, Unloading, Shifting, Installation Testing & Commissioning of 33 KV Single Breaker Vacuum Circuit Breaker Panel Board as Incomming / Outgoing shall be metal clad floor mounting complete as per specification and as described.
630 A Vacuum circuit breaker of (1000 MVA) 26.3 KA RMS for 3 second ruputuring capacity for at 33 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation, vermin proof, fully interlocked horizontal drawout type having isolation features and control devices complete with the following.
Manually and motor operated, spring charged (release closing mechanism) trip free type,triple pole truck mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indication"OFF" push buttons for emergency trip (shrouded) test/service position limit switches with 6 NO/6 NC breaker auxilliary contacts in service position, 24 Volts DC shunt trip coil and strip heater to prevent moisture absorption.
INCOMING/OUTGOING PANEL - 1 NO.
630 A Vacuum circuit breaker of (1000 MVA) 26.3 KA RMS for 3 second ruputuring capacity for at 33 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation, vermin proof, fully interlocked horizontal drawout type having isolation features and control devices complete with the following.
3 No. Single Phase double core current transformer 150/5 Amp epoxy cast insulated class of insulation E.
Core 1-15VA burden class 1.0 for metering.
Core 2-15VA burden class 5P10 for protection.
P.T's of 33KV/1.732, 110V/1.732, 100VA with suitable rating H.T. & L.T. fuse conforming to relevant IS Standards and complete as required.
One no. numerical microprocessor based three phase over current (IDMT element) (2 O/C+1E/F) with earth fault relay with instantaneous elements.
1 No. Anti Pumping device.
1 No. Circuit breaker control switch for electrical (T/N/C).
1 No. limit switch for test & service position.
1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
1 Set of following indicating lamps.
Red, Yellow & Blue for phase indication.
Amber for Trip indication.
Red `ON' Green `OFF'
Spring charge indication.
Auto trip indication.
1 No. hooter with hooter acceptance and reset push button.
1 No. master trip relay. ( Electromechanical Type )
1 No.Trip ckt supervision relay. (Electromechanical Type )
600A color coded heat shrinkable sleeved TP Copper busbar of 350 MVA fault rating.
1 Set of fuses, ferrules, wiring etc. as required.
1 Set of Power Pack 220 Volt A.C. / 24 Volt D.C. complete as required.
Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate ferrules / coding. The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm subjected to providing minimum size strip suitable for 4/6sqmm.
H.T. Panel describe as above
Design, manufacture, supply, installation, testing and commissioning of 2000 KVA, 33 KV /0.415 KV, 3 phase, 50 Hz delta/star-11 connected, OUT DOOR TYPE, copper wound transformer, oil immersed ONAN cooled, complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent with on Load Tap changing (OLTC) arrangement on HV side with Tapping for variations of high voltage from (+) 5% to (-)15% in steps of 2.5% each with integrated microprocessor based RTCC Panel, bi-directional roller, diagrams & rating plate, Oil temperature indicator, & Winding temperature indicator, Buchholz relay, weather proof Marshalling Box, lifting lugs, first filling of oil, weather proof H.Tcable box & L.T Bus duct arrangement etc. complete as per specification. All relays, contacts & CT terminals to be wired upto marshalling box. Transformer shall be as per latest IS 1180 - 2014, Star-1.
33 KV H.T. CABLE:
Supplying of 33 KV (E) grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required.
3C x 240 Sqmm, 33 KV XLPE
DIESEL GENERATING SET:
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Storing, Installation, Testing and Commissioning of Radiator Cooled DG sets of following capacity with Accoustic Enclosure, db level as per latest CPCB, 415Volts, 3 phase, 50 Hz AC alternator coupled to diesel engine with Electronic Governer Suitable for Auto Load Sharing and Auto Synchronizing System complete with all accessories, standard specifications tool kits, service manual, self starting device, fly wheel, coupling with guard, V velt, radiator, instrument panel (starting switch with key, Water Temperature indicator gauge, Lub OIl Pressure gauge, Lube oil temperature gauge, Battery Charging Ammeter, indicating lamp, hour counter etc.), residential silencer, common bed plate, anti vibration isolation pads, extended termination box for busduct termination, grouting bolts, first charge of engine oil, gear oil, high speed diesel oil, 24 volt maintenance free chargeable battery set with Trickle/Boost Battery charger, interface card for BMS connectivity complete as required of rating 415 Volts, 3 phase, 50 Hz. AC alternator coupled to Diesel Engine complete with all accessories. NOC from concerned goverment authority for installation and operation of D.G. set shall be taken by contractor. D.G. Set shall be as per CPCB-II.
1500 KVA D.G. Set with suitable capacity of day oil fuel Tank
500 KVA D.G. Set with suitable capacity of day oil fuel Tank
EXHAUST PIPING
Supply, installation, testing and commissioning of following sizes MS exhaust piping heavy duty conforming to IS:1239 & 3589 complete with all accessories such as bends, flanges, stainless steel flexible bellows etc as complete as required.
450 mm dia MS pipe. (5.2 mm thick)
300 mm dia MS pipe. (5.2 mm thick)
250 mm dia MS pipe. (5.2 mm thick)
Providing & Fixing of Insulation with rockwool of min 75mm. thickness min. 144Kg/ m3 density and 26 SWG Aluminium cladding.
Fabrication, supply & erection of MS structure for supporting of DG emission, exhaust piping with RCC foundation and in cable trench for cable support etc. complete in all respect.
SAFETY EQUIPMENT
First aid box as approved by St.John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963.
Shock treatment chart duly mounted on a wooden frame with glass on, as required in 2 languages (Hindi & English).
Rubber mat 1000 mm. Wide to withstand 33 KV dielectric strength as per latest IS 15652-2006.
DG Synchronizing Cum Changeover Panel (3x1500 KVA D.G. Set + 1x500 KVA D.G. Set)- EXPANDABLE TYPE
Supply, Erection, Testing & Commissioning of Main DG Control panel with D.G. Synchronizing controller & Micro PLC, this will be floor mounted, free standing, compartmentalized, indoor duty, dust proof, vermin proof, front operated, electrical panel fabricated, painted and manufactured exactly as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth terminals, earth bus and will be powdered coated finished. All the busbar joint shall be protected by clip on type sleeve. The DG control panel shall use all draw out 3 position withdrawn type breakers suitable for 415 V AC, 3 phase, 50 Hz, 4 wire supply system and will have fault level of 65 KA or as required as per consultant approval. The panel will be made as per detailed specifications and drawings forming part of this document. (Under no case temperature of LT Panel shall be more at any point of the panel, otherwise necessary exhaust fan shall be have to provided) Bus bar calculations considering temperature derating, enclosure derating, sleeving derating must be done and submitted for checking. (The D.G. Set controller shall be part of D.G. Set).
The DG vendor shall make complete protection curves and discrimination chart for relay settings and shall adjust all these readings at site. The bus bar size shall not be less than the ampere sizes mentions after derating. The bidder will show exact calculations & compare the figure of 0.66 and final calculations will be adopted for more stringent condition. each incommer shall have surge protection device. The PCC panel will comprise of the following :
Each incoming / outgoing breaker shall have microprocessor release with adjustable over current, short circuit & earth fault protection with instantaneous as mentioned in specification. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 65 KA.
All the MCCB up to 250 Amp shall have thermal release with adustable overload, short circuit & earth fault protection and above shall have microprocessor release with adjustable overload, short circuit & earthfault protection. The panel shall be manufactured as per BOQ, tech specification and drawing. Fault level of panel shall be 65 KA.
One set of PLC with required accessories for AMF, Load Management, Interlocking and synchronizing through synchronizing relay. PLC shall be with PC, Monitor, required software to monitoring the all parameters for Synchronizing Panel & Main L.T. Panel.
1 Nos. 2500A feeder incomer and Each incomer breaker feeder shall have following: (For 1500 KVA D.G. Set)-
One set of Generator control relay for Each D.G. Set with accessories for AMF, Synchronizing.
One number incomer 3P 2500 amps EDO breaker with 500 Amp TP neutral contactor. Each breaker shall have microprocessor based releases for O/C, S/C & earth fault protection with instantaneous.
3 No. indicating lamps to show the incoming power along with HRC fuses.
1 No. Load Manager EM 6400 with RS 485 port
1 no. REF relay
Announciation window to cover LLOP, HWT, OIL Pressure, U/V, O/V, U/F, O/F, O/C, E/F, REF relay faults shall be provided. 2 nos phase reversal relay shall be provided.
Engine should trip on LLOP, HWT, oil temp, O/V, O/F and breaker should trip on other faults.
Initially U/V & U/F will be bye passed till oil pressure is picked up.
Indicating lights for ACB ON / OFF, ACB trip, neutral contactor ON, D.G. on mains, D.G. fails to start.
Generator start /stop facility through push button from panel, necessary cranking relay shall be provided.
Suitable battery charger for 24V 360 AH with d.c voltmeter & d.c ammeter. D.C voltmeter and ammeter will be analouge type.
Whenever D.G. stop through PB, load shall be disconnected first.
1 Nos. 800A feeder incomer and Each incomer breaker feeder shall have following: (For 500 KVA D.G. Set)-
One set of Generator control relay for Each D.G. Set with accessories for AMF, Synchronizing.
One number incomer 3P 800 amps EDO breaker with 500 Amp TP neutral contactor. Each breaker shall have microprocessor based releases for O/C,S/C & earth fault protection with instantaneous.
3 No. indicating lamps to show the incoming power along with HRC fuses.
1 No. Load Manager EM 6400 with RS 485 port
1 no. REF relay
Announciation window to cover LLOP, HWT, OIL Pressure, U/V, O/V, U/F, O/F, O/C, E/F, REF relay faults shall be provided. 2 nos phase reversal relay shall be provided.
Engine should trip on LLOP, HWT, oil temp, O/V, O/F and breaker should trip on other faults.
Initially U/V & U/F will be bye passed till oil pressure is picked up.
Indicating lights for ACB ON / OFF, ACB trip, neutral contactor ON, D.G. on mains, D.G. fails to start.
Generator start /stop facility through push button from panel, necessary cranking relay shall be provided.
Suitable battery charger for 24V 360 AH with d.c voltmeter & d.c ammeter. D.C voltmeter and ammeter will be analouge type.
Whenever D.G. stop through PB, load shall be disconnected first.
Incomming Feeder from Main L.T. Panel (Grid Supply):
1 No. 3200 Amp FP Electrically operated horizontal drawout type Air Circuit Breaker microprocessor based releases for O/C, S/C & earth fault protection with instantaneous. (For Incommer) (65 KA)
BUSCOUPLER
2 No. 3200Amp FP Electrically operated horizontal drawout type Air Circuit Breaker as buscoupler with interlocking arrangement with incomers. (65 KA)
2 Sets of indicating lamps for ON & OFF of bus coupler.
BUSBARS
5000 Amp TPN busbars of aluminium alloy as per SLD.
OUTGOING
EACH OUTGOING FEEDER SHALL HAVE DIGITAL DUAL SOURCE ENERGY METER
03 Nos 1000A FP Moulded Case Circuit Breaker.
01 Nos 800A FP Moulded Case Circuit Breaker.
02 Nos 630A FP Moulded Case Circuit Breaker.
01 Nos 500A FP Moulded Case Circuit Breaker.
04 Nos 300A FP Moulded Case Circuit Breaker.
04 Nos 160A FP Moulded Case Circuit Breaker.
07 Nos 100A FP Moulded Case Circuit Breaker.
04 Nos 63A FP Moulded Case Circuit Breaker.
INSTRUMENTS
3 No. 0 to 3200 Amp digital ammeter (96mm square) with CT's.
3 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).
3 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).
3 Sets trip circuit healthy indicating lamp (one set for each incoming breaker).
3 Sets auto trip indicating lamp (one set for each incoming breaker).
3 Nos. Multifunction Meter (one for each Incoming Breaker).
BATTERY & BATTERY CHARGER
1 No. 24V, 72AH SMF Battery with suitable battery charger for control supply.
D.G. Synchronizing Panel Describe as above.
MAIN L.T. PANEL & CAPACITOR PANEL - EXPANDABLE TYPE
Each incoming / outgoing breaker shall have microprocessor release with adjustable over current, short circuit & earth fault protection with instantaneous as mentioned in specification. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 65 KA.
All the MCCB up to 250 Amp shall have thermal release with adustable overload, short circuit & earth fault protection and above shall have microprocessor release with adjustable overload, short circuit & earthfault protection. The panel shall be manufactured as per BOQ, tech specification and drawing. Fault level of panel shall be 65 KA.
INCOMING
2 No. 3200 Amp FP Electrically operated horizontal drawout type Air Circuit Breaker. (For Incommer) (65 KA)
BUSCOUPLER
3 Nos. 3200Amp FP Electrically operated horizontal drawout type Air Circuit Breaker as buscoupler with interlocking arrangement with incomers. (65 KA)
3 Sets of indicating lamps for ON & OFF of bus coupler.
BUSBARS
4000 Amp TPN busbars of aluminium alloy as per SLD.
OUTGOING
EACH OUTGOING FEEDER SHALL HAVE DIGITAL ENERGY METER
2 Nos. 3200 Amp FP MDO Air Circuit Breaker.
1 Nos. 2000 Amp FP MDO Air Circuit Breaker.
2 Nos. 1600 Amp FP MDO Air Circuit Breaker.
1 Nos. 630 Amp FP Moulded Case Circuit Breaker.
2 Nos. 400 Amp FP Moulded Case Circuit Breaker.
3 Nos. 250 Amp FP Moulded Case Circuit Breaker.
2 Nos. 160 Amp FP Moulded Case Circuit Breaker.
1 Nos. 100 Amp FP Moulded Case Circuit Breaker.
INSTRUMENTS
2 No. 0 to 3200 Amp digital ammeter (96mm square) with CT's.
5 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).
5 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).
2 Sets trip circuit healthy indicating lamp (one set for each incoming breaker).
2 Sets auto trip indicating lamp (one set for each incoming breaker).
2 Set of CT's one of 4000/ 5Amp ratio for APFC relay.
2 Nos. Frequency meter (one for each Incoming Breaker).
2 Nos. master trip relay (one for each Incoming Breaker).
BATTERY & BATTERY CHARGER
1 No. 24V, 72AH SMF Battery with suitable battery charger.
CAPACITOR BANK PANEL (800 KVAR) (ALL CAPACITOR PANEL SHALL BE PART OF MAIN L.T. PANEL) - 04 SET. (EACH CAPACITOR PANEL SHALL HAVE FOLLOWING)-
INCOMING
1 No. 0 to 1600 Amp digital ammeter (96mm square) with CT's.
1 Sets of phase indicating lights (RYB) with protection fuses.
1 Sets breaker 'ON' & 'OFF' indicating lamp.
14 Step Automatic Power Factor Correction relay (APFC relay).
BUSBARS
2000 Amp TPN busbars of aluminium alloy as per SLD.
OUTGOING
6 Nos. 250 Amp TP MCCB.
2 Nos. 125 Amp TP MCCB.
4 Nos. 63 Amp TP MCCB.
6 Nos. capacitor duty contactor (one for each 100KVAR capacitor unit).
2 Nos. capacitor duty contactor (one for each 50KVAR capacitor unit).
4 Nos. capacitor duty contactor (one for each 25KVAR capacitor unit).
6 Nos. 100 KVAR Capacitor Bank with 14% reactor.
2 Nos. 50 KVAR Capacitor Bank with 14% reactor.
4 Nos. 25 KVAR Capacitor Bank with 14% reactor.
1 No. Indicating lamp for each 100 / 50 / 25 KVAR capacitor unit to indicate that the unit is 'ON'.
1 No. Toggle switch for changing automatic to manual operation of capacitor units.
Power factor meter.
Main L.T. Panel & Capacitor Panel describe as above
BUS DUCT (OUTDOOR TYPE)
Supplying, Installation, Testing and Commissioning of following capacity Outdoor Type Sandwich Type Bus duct for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with metal clad enclosure having IP-54 rating made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 130 A/sq. cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every meter, adopter box and copper flexible for joints, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.
Compact sandwich 3200A aluminium (after deratings), 65KA short ckt. for one second at the temperature rise of 45 deg. above ambient of 45 deg. with min.2 nos. external alm. earth strip suitable for 65KA, end cover, with all bends, expansion joints and necessary expansion bellow & all items described above in heading.
Compact sandwich 2500A aluminium (after deratings), 65KA short ckt. for one second at the temperature rise of 45 deg. above ambient of 45 deg. with min.2 nos. external alm. earth strip suitable for 65KA, end cover, with all bends, expansion joints and necessary expansion bellow & all items described above in heading.
Compact sandwich 2000A aluminium (after deratings), 65KA short ckt. for one second at the temperature rise of 45 deg. above ambient of 45 deg. with min.2 nos. external alm. earth strip suitable for 65KA, end cover, with all bends, expansion joints and necessary expansion bellow & all items described above in heading.
Compact sandwich 800A aluminium (after deratings), 65KA short ckt. for one second at the temperature rise of 45 deg. above ambient of 45 deg. with min.2 nos. external alm. earth strip suitable for 65KA, end cover, with all bends, expansion joints and necessary expansion bellow & all items described above in heading.
Supply & Laying of following sizes of 1.1KV grade multicore copper conductor PVC insulated and PVC sheathed armoured control cable conforming to IS:7098 (Part-I) 1988, including end termination with brass compression gland and copper lugs.
2 core, 6.0 sq.mm
4 core, 1.5 sq.mm
8 core, 1.5 sq.mm
12 core, 1.5 sq.mm
HT PANEL
11KV H.T. METERING PANEL (INDOOR TYPE):
Supply, Receiving, Unloading, Storing, Shifting, Installation, Testing & Commissioning of indoor type floor mounted, dust, damp and vermin proof, cubicle HT. Metering Panel made out of 14 gauge CRCA sheet steel complete with 5Amp electronic trivector meter, C.T.'s of 100/5Amp, 0.5 Class, 10VA Burden, and P.T's of 11KV/ /3, 110V/ /3, 100 VA conforming to relevant IS Standards and complete as required. H.T. Metering cubicle along with C.T.'s, P.T.'s and trivector meter shall be got tested and approved from local electricity supply authority. The GA drawing shall be got approved by ELECTRICITY BOARD authorities before fabrication.
11 KV HT VCB Single Breaker Panel Board (Indoor Type) (1 Incomming / Outgoing)
Supply, Receiving, Unloading, Shifting, Installation Testing & Commissioning of 11 KV Single Breaker Vacuum Circuit Breaker Panel Board as 1 Incomming / Outgoing shall be metal clad floor mounting complete as per specification and as described.
630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation, vermin proof, fully interlocked horizontal drawout type having isolation features and control devices complete with the following.
Manually and motor operated, spring charged (release closing mechanism) trip free type,triple pole truck mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indication"OFF" push buttons for emergency trip (shrouded) test/service position limit switches with 6 NO/6 NC breaker auxilliary contacts in service position, 24 Volts DC shunt trip coil and strip heater to prevent moisture absorption.
INCOMING / OUTGOING PANEL - 1 NO.
1 No 630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation,vermin proof,fully interlocked horizontal drawout type having isolation features and control devices complete with the following:
3 No. Single Phase double core current transformer 100/5 Amp epoxy cast insulated class of insulation E.
Core 1-15VA burden class 1.0 for metering.
Core 2-15VA burden class 5P10 for protection.
P.T's of 11KV/1.732, 110V/1.732, 100VA with suitable rating H.T. & L.T. fuse conforming to relevant IS Standards and complete as required.
One no. numerical microprocessor based three phase over current (IDMT element) (2 O/C+1E/F) with earth fault relay with instantaneous elements.
1 No. Anti Pumping device.
1 No. Circuit breaker control switch for electrical (T/N/C).
1 No. limit switch for test & service position.
1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
1 Set of following indicating lamps.
Red, Yellow & Blue for phase indication.
Amber for Trip indication.
Red `ON' Green `OFF'
Spring charge indication.
Auto trip indication.
1 No. hooter with hooter acceptance and reset push button.
1 No. master trip relay. ( Electromechanical Type )
1 No.Trip ckt supervision relay. (Electromechanical Type )
600A color coded heat shrinkable sleeved TP Copper busbar of 350 MVA fault rating.
1 Set of fuses, ferrules, wiring etc. as required.
1 Set of Power Pack 220 Volt A.C. / 24 Volt D.C. complete as required.
1 No. control Transformer of 1KVA for giving supply to indication lamps etc having 11 KV/415-230V AC rating epoxy cast resin dry type Transformer. The connection for control transformer shall be taken from the cable side before the circuit breaker tapping.
Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate ferrules / coding. The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm subjected to providing minimum size strip suitable for 4/6sqmm.
H.T. Panel describe as above
11 KV HT VCB Four Breaker Panel Board (Indoor Type) (1 Incomming + 3 Outgoing)
Supply, Receiving, Unloading, Shifting, Installation Testing & Commissioning of 11 KV Four Breaker Vacuum Circuit Breaker Panel Board as 1 Incomming & 3 Outgoing shall be metal clad floor mounting complete as per specification and as described.
630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation, vermin proof, fully interlocked horizontal drawout type having isolation features and control devices complete with the following.
Manually and motor operated, spring charged (release closing mechanism) trip free type,triple pole truck mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indication"OFF" push buttons for emergency trip (shrouded) test/service position limit switches with 6 NO/6 NC breaker auxilliary contacts in service position, 24 Volts DC shunt trip coil and strip heater to prevent moisture absorption.
INCOMING PANEL - 1 NO.
1 No 630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation,vermin proof,fully interlocked horizontal drawout type having isolation features and control devices complete with the following:
3 No. Single Phase double core current transformer 100/5 Amp epoxy cast insulated class of insulation E.
Core 1-15VA burden class 1.0 for metering.
Core 2-15VA burden class 5P10 for protection.
P.T's of 11KV/1.732, 110V/1.732, 100VA with suitable rating H.T. & L.T. fuse conforming to relevant IS Standards and complete as required.
One no. numerical microprocessor based three phase over current (IDMT element) (2 O/C+1E/F) with earth fault relay with instantaneous elements.
1 No. Anti Pumping device.
1 No. Circuit breaker control switch for electrical (T/N/C).
1 No. limit switch for test & service position.
1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
1 Set of following indicating lamps.
Red, Yellow & Blue for phase indication.
Amber for Trip indication.
Red `ON' Green `OFF'
Spring charge indication.
Auto trip indication.
1 No. hooter with hooter acceptance and reset push button.
1 No. master trip relay. ( Electromechanical Type )
1 No.Trip ckt supervision relay. (Electromechanical Type )
600A color coded heat shrinkable sleeved TP Copper busbar of 350 MVA fault rating.
1 Set of fuses, ferrules, wiring etc. as required.
1 Set of Power Pack 220 Volt A.C. / 24 Volt D.C. complete as required.
1 No. control Transformer of 1KVA for giving supply to indication lamps etc having 11 KV/415-230V AC rating epoxy cast resin dry type Transformer. The connection for control transformer shall be taken from the cable side before the circuit breaker tapping.
Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate ferrules / coding. The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm subjected to providing minimum size strip suitable for 4/6sqmm.
OUTGOING PANEL - 3 NO. (Each outgoing feeder shall have following)
1 No 630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation,vermin proof,fully interlocked horizontal drawout type having isolation features and control devices complete with the following:
3 No. Single Phase double core current transformer 40/5 Amp epoxy cast insulated class of insulation E.
Core 1-15VA burden class 1.0 for metering.
Core 2-15VA burden class 5P10 for protection.
One no. numerical microprocessor based three phase over current (IDMT element) (2 O/C+1E/F) with earth fault relay with instantaneous elements.
1 No. Anti Pumping device.
1 No. Circuit breaker control switch for electrical (T/N/C).
1 No. limit switch for test & service position.
1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
1 Set of following indicating lamps.
Red, Yellow & Blue for phase indication.
Amber for Trip indication.
Red `ON' Green `OFF'
Spring charge indication.
Auto trip indication.
1 No. hooter with hooter acceptance and reset push button.
1 No. master trip relay. ( Electromechanical Type)
1 No.Trip ckt supervision relay (Electromechanical Type)
1 Set of fuses, ferrules, wiring etc. as required.
4 No. VAA33 auxiliary relay for transformer fault, alarm and trip.
12 Annunciator window for all electrical and transformer fault.
Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate ferrules / coding. The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm subjected to providing minimum size strip suitable for 4/6sqmm.
H.T. Panel describe as above
TRANSFORMER (11 KV / 0.415 KV):
Design, manufacture, supply, installation, testing and commissioning of 630 KVA, 11 KV /0.415 KV, 3 phase, 50 Hz delta/star-11 connected, OUTDOOR TYPE, copper wound transformer, oil immersed ONAN cooled, complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent with on Load Tap changing (OLTC) arrangement on HV side with Tapping for variations of high voltage from (+) 5% to (-)15% in steps of 2.5% each with integrated microprocessor based RTCC Panel, bi-directional roller, diagrams & rating plate, Oil temperature indicator, & Winding temperature indicator, Buchholz relay, weather proof Marshalling Box, lifting lugs, first filling of oil, weather proof H.T & L.T. cable box arrangement for cable termination etc. complete as per specification. All relays, contacts & CT terminals to be wired upto marshalling box. Transformer shall be as per latest IS 1180 - 2014, Star-1.
630 KVA rating
11 KV H.T. CABLE:
Supplying of 11 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required.
3C x 240 Sqmm, 11 KV XLPE
HT CABLE LAYING:
11KV cable laying upto 400 sq.mm. in pipes.
DIESEL GENERATING SET:
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Storing, Installation, Testing and Commissioning of Radiator Cooled DG sets of following capacity (rating in kVA) compact packaged silent type, with Outdoor type Acoustic Enclosure to reduce the noise level as per requirements of central pollution control board, 415Volts, 3 phase, 50 Hz AC alternator coupled to diesel engine with mechanical governor complete with all accessories, standard specifications tool kits, service manual, self starting device, fly wheel, coupling with guard, V velt, radiator, instrument panel (starting switch with key, Water Temperature indicator gauge, Lub OIl Pressure gauge, Lube oil temperature gauge, Battery Charging Ammeter, indicating lamp, hour counter etc.), residential silencer with insulation & aluminium cladding, common bed plate, anti vibration isolation pads, extended cable termination box, grouting bolts, first charge of engine oil, gear oil, high speed diesel oil, 12 volt maintenance free chargeable battery set with Trickle/Boost Battery charger, interface card for BMS connectivity complete as required of rating 415 Volts, 3 phase, 50 Hz. AC alternator coupled to Diesel Engine complete with all accessories. NOC from concerned goverment authority for installation and operation of D.G. set shall be taken by contractor. D.G. Set shall be as per CPCB-II.
320 KVA D.G. Set with suitable capacity of day oil fuel Tank
EXHAUST PIPING
Supply, installation, testing and commissioning of following sizes MS exhaust piping heavy duty conforming to IS:1239 & 3589 complete with all accessories such as bends, flanges, stainless steel flexible bellows etc as complete as required.
250 mm dia MS pipe. (5.2 mm thick)
150 mm dia MS pipe. (B Class)
Providing & Fixing of Insulation with rockwool of min 75mm. thickness min. 144Kg/ m3 density and 26 SWG Aluminium cladding.
Fabrication, supply & erection of MS structure for supporting of DG emission, exhaust piping with RCC foundation and in cable trench for cable support etc. complete in all respect.
Supply & Laying of following sizes of 1.1KV grade multicore copper conductor PVC insulated and PVC sheathed armoured control cable conforming to IS:7098 (Part-I) 1988, including end termination with brass compression gland and copper lugs.
2 core, 6.0 sq.mm
4 core, 1.5 sq.mm
8 core, 1.5 sq.mm
12 core, 1.5 sq.mm
SAFETY EQUIPMENT
Shock treatment chart duly mounted on a wooden frame with glass on, as required in 2 languages (Hindi & English).
Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652 -2006.
DG PANEL (1x320 KVA + 1x500 KVA D.G. SET)-
Supply, Installation, Testing & Commissioning of Main DG Control panel cum changeover panel with Micro PLC for AMF, Load Management & Interlocking. This will be floor mounted, free standing, compartmentalized, indoor duty, dust proof, vermin proof, front operated, electrical panel fabricated, painted and manufactured exactly as per specifications laid in this document and will be complete with the main and auxiliary bus bars, interconnection, earth terminals, earth bus and will be powdered coated finished. All the busbar joint shall be protected by clip on type sleeve. The panel shall use all draw out 3 position withdrawn type breakers suitable for 415 V AC, 3 phase, 50 Hz, 4 wire supply system and will have fault level of 50 KA or as required as per consultant approval. The panel will be made as per detailed specifications and drawings forming part of this document. Bus bar calculations considering temperature derating, enclosure derating, sleeving derating must be done and submitted for checking.
Each incoming breaker shall have microprocessor release with adjustable over current, short circuit & earth fault protection with instantaneous as mentioned in specification. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel & breaker shall be 50 KA.
All the MCCB up to 250 Amp shall have thermal release with adustable overload, short circuit and above shall have microprocessor release with adjustable overload, short circuit & earthfault protection. The panel shall be manufactured as per BOQ, tech specification and drawing. Fault level of MCCB shall be 35 KA.
2 No. 800 Amp FP Electrically operated horizontal drawout type Air Circuit Breaker microprocessor based releases for O/C,S/C & earth fault protection with instantaneous. (For Incommer) (50 KA)
2 No. 630 Amp FP Electrically operated horizontal drawout type Air Circuit Breaker microprocessor based releases for O/C,S/C & earth fault protection with instantaneous. (For Incommer) (50 KA)
BUSCOUPLER
01 No. 630 Amp FP Electrically operated horizontal drawout type Air Circuit Breaker.
1 Sets of indicating lamps for ON & OFF of bus coupler.
BUSBARS
1000 Amp TPN busbars of aluminium alloy as per SLD.
OUTGOING
01 Nos 630A TP+N Moulded Case Circuit Breaker.
03 Nos 500A TP+N Moulded Case Circuit Breaker.
01 Nos 400A TP+N Moulded Case Circuit Breaker.
02 Nos 200A TP+N Moulded Case Circuit Breaker.
02 Nos 160A TP+N Moulded Case Circuit Breaker.
05 Nos 63A TP+N Moulded Case Circuit Breaker.
INSTRUMENTS
2 No. 0 to 800 Amp digital ammeter (96mm square) with CT's.
2 No. 0 to 250 Amp digital ammeter (96mm square) with CT's.
4 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).
4 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).
4 Sets trip circuit healthy indicating lamp (one set for each incoming breaker).
4 Sets auto trip indicating lamp (one set for each incoming breaker).
2 Nos. Multifunction Meter (one for each Incoming Breaker).
BATTERY & BATTERY CHARGER
1 No. 24V, 72AH SMF Battery with suitable battery charger for control supply.
D.G. Distribution Panel Describe as above.
MAIN L.T. PANEL & CAPACITOR PANEL
Each Incoming / Outgoing breaker shall have microprocessor release with adjustable over current, short circuit & earth fault protection with instantaneous as mentioned in specification. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 50 KA.
All the MCCB up to 250 Amp shall have thermal release with adustable overload, short circuit & earth fault protection and above shall have microprocessor release with adjustable overload, short circuit & earthfault protection. The panel shall be manufactured as per BOQ, tech specification and drawing. Fault level of panel shall be 35 KA.
INCOMING
03 No. 1250 Amp FP Electrically operated horizontal drawout type Air Circuit Breaker.
BUSCOUPLER
02 No. 1250 Amp FP Electrically operated horizontal drawout type Air Circuit Breaker.
BUSBARS
1600 Amp TPN busbars of aluminium alloy as per SLD.
OUTGOING
01 Nos. 800 Amp FP MDO Air Circuit Breaker.
01 Nos. 630 Amp FP MDO Air Circuit Breaker.
03 Nos. 630 Amp FP Moulded Case Circuit Breaker.
03 Nos. 500 Amp FP Moulded Case Circuit Breaker.
02 Nos. 250 Amp FP Moulded Case Circuit Breaker.
01 Nos. 200 Amp FP Moulded Case Circuit Breaker.
01 Nos. 160 Amp FP Moulded Case Circuit Breaker.
INSTRUMENTS
03 No. 0 to 1250 Amp digital ammeter (96mm square) with CT's.
03 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).
03 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).
03 Sets trip circuit healthy indicating lamp (one set for each incoming breaker).
03 Sets auto trip indicating lamp (one set for each incoming breaker).
03 Set of CT's one of 1250/ 5Amp ratio for APFC relay.
03 Nos. Frequency meter (one for each Incoming Breaker).
03 Nos. master trip relay (one for each Incoming Breaker).
1 Set Electrical & Mechanical Interlocking between Incommer & Buscoupler.
BATTERY & BATTERY CHARGER
1 No. 24V, 72AH SMF Battery with suitable battery charger.
CAPACITOR BANK PANEL (300 KVAR) (ALL CAPACITOR PANEL SHALL BE PART OF MAIN L.T. PANEL) - 03 SET. (EACH CAPACITOR PANEL SHALL HAVE FOLLOWING)-
INCOMING
1 No. 0 to 500 Amp digital ammeter (96mm square) with CT's.
1 Sets of phase indicating lights (RYB) with protection fuses.
1 Sets breaker 'ON' & 'OFF' indicating lamp.
14 Step Automatic Power Factor Correction relay (APFC relay).
BUSBARS
800 Amp TPN busbars of aluminium alloy as per SLD.
OUTGOING
04 Nos. 125 Amp TP MCCB.
03 Nos. 63 Amp TP MCCB.
03 Nos. 32 Amp TP MCCB.
04 Nos. capacitor duty contactor (one for each 50KVAR capacitor unit).
03 Nos. capacitor duty contactor (one for each 25KVAR capacitor unit).
03 Nos. capacitor duty contactor (one for each 10/5KVAR capacitor unit).
04 Nos. 50 KVAR Capacitor Bank.
03 Nos. 25 KVAR Capacitor Bank.
03 Nos. 10/5 KVAR Capacitor Bank.
1 No. Indicating lamp for each 50/25/10/5 KVAR capacitor unit to indicate that the unit is 'ON'.
1 No. Toggle switch for changing automatic to manual operation of capacitor units.
Power factor meter.
Main L.T. Panel & Capacitor Panel describe as above
FEEDER PILLAR (OUTDOOR TYPE)-
EXTERNAL LIGHTING PANEL-
INCOMING
1 No. 63 Amp FP ( 35 KA Ics) Moulded Case Circuit Breaker.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
1 Set 24 Hrs TSQ Timer
1 Set 100 Amp, 4P Contactor & A/M switch and Push Button.
BUS BARS
100 Amp TPN aluminium busbar.
OUTGOING
08 No. 25 Amp DP MCB.
03 No. 40 Amp DP MCB.
Panel described as above
EXTERNAL LIGHTING WORK-
Supply, Installation, Testing & Commissioning of 11 Mtr High hot dip Galvanized Octagonal Pole with bottom 210mm A/F, top 90 mm A/F made up of 3 mm thick HT plate and 300x300x20 mm base plate and 1000 mm long single arm bracket complete with 4 Nos 24mm dia x 750 mm long foundation bolts, RCC foundation etc as complete as required.
Supply, Installation, Testing & Commissioning of 7 Mtr High hot dip Galvanized Octagonal Pole with bottom 130mm A/F, top 70 mm A/F made up of 3 mm thick HT plate and 220x220x16 mm base plate, fixing arrangement of light complete with 4 Nos 24mm dia x 700 mm long foundation bolts, RCC foundation etc as complete as required.
Supply, Installation, Testing & Commissioning of 6 Mtr High hot dip Galvanized Octagonal Pole with bottom 130mm A/F, top 70 mm A/F made up of 3 mm thick HT plate and 220x220x16 mm base plate and 1000 mm long single arm bracket complete with 4 Nos 24mm dia x 600 mm long foundation bolts, RCC foundation etc as complete as required.
Supply, Installation, Testing & Commissioning of 6 Mtr High hot dip Galvanized Octagonal Pole with bottom 130mm A/F, top 70 mm A/F made up of 3 mm thick HT plate and 220x220x16 mm base plate and 1000 mm long double arm bracket complete with 4 Nos 24mm dia x 600 mm long foundation bolts, RCC foundation etc as complete as required.
Supply, Installation, Testing & Commissioning of 4 Mtr High hot dip Galvanized Octagonal Pole with bottom 130mm A/F, top 70 mm A/F made up of 3 mm thick HT plate and 220x220x12 mm base plate and 750 mm long single arm bracket complete with 4 Nos 20mm dia x 450 mm long foundation bolts, RCC foundation etc as complete as required.
Supply, Installation, Testing & Commissioning of LED light fixture 120 watt, 12000 lumen, integral driver, protection IP 66, CLASS I as complete as required. (Make Philips, Cat No- BVP120 LED 70 CW NB FG S1 PSU GR or equivalent).
Supply, Installation, Testing & Commissioning of LED light fixture 40 watt, integral driver, protection IP 66, CLASS I as complete as required. (Make Philips, Cat No- BRP 409 LED 040 CW HO MR FG S1 PSU GR or equivalent).
Supply, Installation, Testing & Commissioning of LED light fixture 172 watt, integral driver, protection IP 66, CLASS I as complete as required. (Make Philips, Cat No-BVP410 LED 172 CW HE NB FG S3 XT or equivalent).
Supply, Installation, Testing & Commissioning of LED street light fixture 20 watt, clour cool white , integral driver, protection IP 65 as complete as required. (Make Philips, BRP022 LED 20 CW MR S1 PSU GR or equivalent).
Supply, Receiving, Unloading, Shifting, Installation, Testing & commissioning of Bollard Light 170 mm dia, 780 mm height made out of cast aluminium lighting fixture, glass diffuser, stainless steel screw, extruded aluminium poles, corrossion & UV resistant coation of 1 x 18 watt CFL (TC-D) of Lustre Make - Cat No LI 8089 or equivalent.
Supply, Receiving, Unloading, Shifting, Installation, Testing & commissioning of gate light 1 x 70 watt SON of Philips Make - SPC 101 or equivalent.
Supply, Receiving, Unloading, Shifting, Installation, Testing & commissioning of spike light 1 x 50 watt GU-10 Light with lamp of Lustre Make - Cat No LI-7008 or equivalent.
Supply, installation, testing and commissionin of following polycarbonate weather proof (IP-55) junction boxes including terminal/ connector block complete as required.
Two way
FEEDER PILLAR (OUTDOOR TYPE)-
EXTERNAL LIGHTING PANEL-
INCOMING
1 No. 63 Amp FP ( 35 KA Ics) Moulded Case Circuit Breaker.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
1 Set 24 Hrs TSQ Timer
1 Set 100 Amp, 4P Contactor & A/M switch and Push Button.
BUS BARS
100 Amp TPN aluminium busbar.
OUTGOING
16 No. 25 Amp DP MCB.
06 No. 40 Amp DP MCB.
Panel described as above
HSD FUEL YARD
Supply, Installation, Testing & Commissioning of 25 KL capacity mild steel horizontal cylindrical underground HSD tank (2.5M dia & 5.5M length) with shell 6mm and end plate 10mm thick suitable for underground installation complete with manhole accessories, fittings, piping inside the tank Decanting hose, bucket filter etc. with paint with inside surface scrapped clean. Tank will be tested at works under hydrostatic pressure of 5 psi before being painted with two coats of Red Oxide Primer as required as per specifications.
Supply, fixing, testing and commissioning of M.S. heavy class ERW piping (Class-C) conforming to IS : l239 with necessary clamps, supports, anti vibration mountings, hangers and fittings such as bends, tees, reducers etc. painted as per specifications:
80 mm dia
40 mm dia
25 mm dia
32 mm dia
VALVES & STRAINERS
Supply, Fixing and Testing of following valves, strainers, in the H.S.D. Fuel Handling System piping complete with companion flanges, nut bolts, gaskets, supports and painted etc. as per specifications.
Ball valves :
80mm dia.
40mm dia.
25mm dia.
32mm dia.
Non return valves :-
40mm dia
Y-strainers :-
40mm dia.
80mm dia.
Supply, Laying, Testing & Commissioning of 1 No. 40mm dia M.S. heavy class ERW piping (Class-C) conforming to IS : 1239 complete with fittings such as bends, tees, reducer sets on surface/hume pipe or directly in ground including excavation, sand cushioning, 4 mm PYPCOT protective covering and refilling the trench etc. as required.
In Ground / On surface
Supply and erection of canopy type M.S.Structure made out of 40mm medium class M.S. pipe (Class-B), 25 x 25 x 3 mm angle iron frame work and 14 SWG GI Sheet. Structure shall be grouted in C.C. 1:2:4 foundation for hanging 4 Nos. 9 litre each fire fighting buckets including providing buckets with two coats of anticorrosive paints etc. complete as required.
Supply and installation of 50ltr capacity Chemical Foam Fire Extinguisher with trolley suitable for Petroleum Fires Protection conforming to IS : 5507.
Supply and installation of 5 kg. capacity dry chemical powder type fire extinguishers conforming to IS : 2171.
Supply of suitable sizes sign boards as per IPR :1976 and fixing the same at various locations within the petroleum installation complete with painting and installation.
Supply & erection of 3 HP Flame Proof positive displacement type HSD pump inside the fuel tank yard having mechanical seal complete with all accessories, fixing on M.S. channel including making earthing as required.
Suction head not less than 3.5 m
Supply and fixing of flow meter for diesel line as required.
80mm dia.
25mm dia.
Supply, Installation, Testing & Commissioning of 32A Flame Proof out door type isolator switch, M.S. Stand, earthing etc complete as required.
Supply, Installation, Testing & Commissioning of a combined starter panel suitable for 2 nos 2.25 KW motor complete as required. (outdoor Type)
11 KV / 0.415KV RESIDENTIAL SUBSTATION
HT PANEL
11KV H.T. METERING PANEL (INDOOR TYPE):
Supply, Receiving, Unloading, Storing, Shifting, Installation, Testing & Commissioning of indoor type floor mounted, dust, damp and vermin proof, cubicle HT. Metering Panel made out of 14 gauge CRCA sheet steel complete with 5Amp electronic trivector meter, C.T.'s of 60/5Amp, 0.5 Class, 10VA Burden, and P.T's of 11KV/ /3, 110V/ /3, 100 VA conforming to relevant IS Standards and complete as required. H.T. Metering cubicle along with C.T.'s, P.T.'s and trivector meter shall be got tested and approved from local electricity supply authority. The GA drawing shall be got approved by ELECTRICITY BOARD authorities before fabrication.
11 KV HT VCB Single Breaker Panel Board (Indoor Type) (1 Incomming / Outgoing)
Supply, Receiving, Unloading, Shifting, Installation Testing & Commissioning of 11 KV Single Breaker Vacuum Circuit Breaker Panel Board as 1 Incomming / Outgoing shall be metal clad floor mounting complete as per specification and as described.
630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation, vermin proof, fully interlocked horizontal drawout type having isolation features and control devices complete with the following.
Manually and motor operated, spring charged (release closing mechanism) trip free type,triple pole truck mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indication"OFF" push buttons for emergency trip (shrouded) test/service position limit switches with 6 NO/6 NC breaker auxilliary contacts in service position, 24 Volts DC shunt trip coil and strip heater to prevent moisture absorption.
INCOMING / OUTGOING PANEL - 1 NO.
1 No 630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation,vermin proof,fully interlocked horizontal drawout type having isolation features and control devices complete with the following:
3 No. Single Phase double core current transformer 60/5 Amp epoxy cast insulated class of insulation E.
Core 1-15VA burden class 1.0 for metering.
Core 2-15VA burden class 5P10 for protection.
P.T's of 11KV/1.732, 110V/1.732, 100VA with suitable rating H.T. & L.T. fuse conforming to relevant IS Standards and complete as required.
One no. numerical microprocessor based three phase over current (IDMT element) (2 O/C+1E/F) with earth fault relay with instantaneous elements.
1 No. Anti Pumping device.
1 No. Circuit breaker control switch for electrical (T/N/C).
1 No. limit switch for test & service position.
1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
1 Set of following indicating lamps.
Red, Yellow & Blue for phase indication.
Amber for Trip indication.
Red `ON' Green `OFF'
Spring charge indication.
Auto trip indication.
1 No. hooter with hooter acceptance and reset push button.
1 No. master trip relay. ( Electromechanical Type )
1 No.Trip ckt supervision relay. (Electromechanical Type )
600A color coded heat shrinkable sleeved TP Copper busbar of 350 MVA fault rating.
1 Set of fuses, ferrules, wiring etc. as required.
1 Set of Power Pack 220 Volt A.C. / 24 Volt D.C. complete as required.
1 No. control Transformer of 1KVA for giving supply to indication lamps etc having 11 KV/415-230V AC rating epoxy cast resin dry type Transformer. The connection for control transformer shall be taken from the cable side before the circuit breaker tapping.
Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate ferrules / coding. The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm subjected to providing minimum size strip suitable for 4/6sqmm.
H.T. Panel describe as above
11 KV HT VCB Four Breaker Panel Board (Indoor Type) (1 Incomming + 2 Outgoing)
Supply, Receiving, Unloading, Shifting, Installation Testing & Commissioning of 11 KV Four Breaker Vacuum Circuit Breaker Panel Board as 1 Incomming & 2 Outgoing shall be metal clad floor mounting complete as per specification and as described.
630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation, vermin proof, fully interlocked horizontal drawout type having isolation features and control devices complete with the following.
Manually and motor operated, spring charged (release closing mechanism) trip free type,triple pole truck mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indication"OFF" push buttons for emergency trip (shrouded) test/service position limit switches with 6 NO/6 NC breaker auxilliary contacts in service position, 24 Volts DC shunt trip coil and strip heater to prevent moisture absorption.
INCOMING PANEL - 1 NO.
1 No 630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation,vermin proof,fully interlocked horizontal drawout type having isolation features and control devices complete with the following:
3 No. Single Phase double core current transformer 60/5 Amp epoxy cast insulated class of insulation E.
Core 1-15VA burden class 1.0 for metering.
Core 2-15VA burden class 5P10 for protection.
P.T's of 11KV/1.732, 110V/1.732, 100VA with suitable rating H.T. & L.T. fuse conforming to relevant IS Standards and complete as required.
One no. numerical microprocessor based three phase over current (IDMT element) (2 O/C+1E/F) with earth fault relay with instantaneous elements.
1 No. Anti Pumping device.
1 No. Circuit breaker control switch for electrical (T/N/C).
1 No. limit switch for test & service position.
1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
1 Set of following indicating lamps.
Red, Yellow & Blue for phase indication.
Amber for Trip indication.
Red `ON' Green `OFF'
Spring charge indication.
Auto trip indication.
1 No. hooter with hooter acceptance and reset push button.
1 No. master trip relay. ( Electromechanical Type )
1 No.Trip ckt supervision relay. (Electromechanical Type )
600A color coded heat shrinkable sleeved TP Copper busbar of 350 MVA fault rating.
1 Set of fuses, ferrules, wiring etc. as required.
1 Set of Power Pack 220 Volt A.C. / 24 Volt D.C. complete as required.
1 No. control Transformer of 1KVA for giving supply to indication lamps etc having 11 KV/415-230V AC rating epoxy cast resin dry type Transformer. The connection for control transformer shall be taken from the cable side before the circuit breaker tapping.
Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate ferrules / coding. The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm subjected to providing minimum size strip suitable for 4/6sqmm.
OUTGOING PANEL - 2 NO. (Each outgoing feeder shall have following)
1 No 630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation,vermin proof,fully interlocked horizontal drawout type having isolation features and control devices complete with the following:
3 No. Single Phase double core current transformer 30/5 Amp epoxy cast insulated class of insulation E.
Core 1-15VA burden class 1.0 for metering.
Core 2-15VA burden class 5P10 for protection.
One no. numerical microprocessor based three phase over current (IDMT element) (2 O/C+1E/F) with earth fault relay with instantaneous elements.
1 No. Anti Pumping device.
1 No. Circuit breaker control switch for electrical (T/N/C).
1 No. limit switch for test & service position.
1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
1 Set of following indicating lamps.
Red, Yellow & Blue for phase indication.
Amber for Trip indication.
Red `ON' Green `OFF'
Spring charge indication.
Auto trip indication.
1 No. hooter with hooter acceptance and reset push button.
1 No. master trip relay. ( Electromechanical Type)
1 No.Trip ckt supervision relay (Electromechanical Type)
1 Set of fuses, ferrules, wiring etc. as required.
4 No. VAA33 auxiliary relay for transformer fault, alarm and trip.
12 Annunciator window for all electrical and transformer fault.
Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate ferrules / coding. The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm subjected to providing minimum size strip suitable for 4/6sqmm.
H.T. Panel describe as above
TRANSFORMER (11 KV / 0.415 KV):
Design, manufacture, supply, installation, testing and commissioning of 500 KVA, 11 KV /0.415 KV, 3 phase, 50 Hz delta/star-11 connected, OUTDOOR TYPE, copper wound transformer, oil immersed ONAN cooled, complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent with on Load Tap changing (OLTC) arrangement on HV side with Tapping for variations of high voltage from (+) 5% to (-)15% in steps of 2.5% each with integrated microprocessor based RTCC Panel, bi-directional roller, diagrams & rating plate, Oil temperature indicator, & Winding temperature indicator, Buchholz relay, weather proof Marshalling Box, lifting lugs, first filling of oil, weather proof H.Tcable box & L.T Bus duct arrangement etc. complete as per specification. All relays, contacts & CT terminals to be wired upto marshalling box. Transformer shall be as per latest IS 1180 - 2014, Star-1.
500 KVA rating
11 KV H.T. CABLE:
Supplying of 11 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required.
3C x 240 Sqmm, 11 KV XLPE
DIESEL GENERATING SET:
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, Storing, Installation, Testing and Commissioning of Radiator Cooled DG sets of following capacity (rating in kVA) compact packaged silent type, with Outdoor type Acoustic Enclosure to reduce the noise level as per requirements of central pollution control board, 415Volts, 3 phase, 50 Hz AC alternator coupled to diesel engine with mechanical governor complete with all accessories, standard specifications tool kits, service manual, self starting device, fly wheel, coupling with guard, V velt, radiator, instrument panel (starting switch with key, Water Temperature indicator gauge, Lub OIl Pressure gauge, Lube oil temperature gauge, Battery Charging Ammeter, indicating lamp, hour counter etc.), residential silencer, common bed plate, anti vibration isolation pads, extended cable termination box, grouting bolts, first charge of engine oil, gear oil, high speed diesel oil, 12 volt maintenance free chargeable battery set with Trickle/Boost Battery charger, interface card for BMS connectivity complete as required of rating 415 Volts, 3 phase, 50 Hz. AC alternator coupled to Diesel Engine complete with all accessories. NOC from concerned goverment authority for installation and operation of D.G. set shall be taken by contractor. D.G. Set shall be as per CPCB-II.
125 KVA D.G. Set with suitable capacity of day oil fuel Tank & AMF Panel.
EXHAUST PIPING
Supply, installation, testing and commissioning of following sizes MS exhaust piping heavy duty conforming to IS : 1239 complete with all accessories such as bends, flanges, stainless steel flexible bellows etc. and fixing/ supporting arrangement etc as required.
100 mm dia MS pipe. (B Class)
Providing & Fixing of Insulation with rockwool of min 75mm. thickness min. 144Kg/ m3 density and 26 SWG Aluminium cladding.
Fabrication, supply & erection of MS structure for supporting of DG emission, exhaust piping with RCC foundation and in cable trench for cable support etc. complete in all respect.
SAFETY EQUIPMENT
Shock treatment chart duly mounted on a wooden frame with glass on, as required in 2 languages (Hindi & English).
Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652 -2006.
DG Panel (1x125 KVA D.G. Set)-
Incomming Feeder
1 No.250 Amp FP Moulded Case Circuit Breaker.
BUSBARS
300 Amp TPN busbars of aluminium alloy as per SLD.
OUTGOING
EACH OUTGOING FEEDER SHALL HAVE DIGITAL DUAL SOURCE ENERGY METER
09 Nos 100A FP Moulded Case Circuit Breaker.
01 Nos 63A FP Moulded Case Circuit Breaker.
INSTRUMENTS
1 No. 0 to 250 Amp digital ammeter (96mm square) with CT's.
1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).
1 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).
1 Sets trip circuit healthy indicating lamp (one set for each incoming breaker).
1 Sets auto trip indicating lamp (one set for each incoming breaker).
1 Nos. Multifunction Meter (one for each Incoming Breaker).
D.G. Distribution Panel Describe as above.
MAIN L.T. PANEL & CAPACITOR PANEL
Each incoming / outgoing breaker shall have microprocessor release with adjustable over current, short circuit & earth fault protection with instantaneous as mentioned in specification. The Panel will be made as per detailed specifications & drawings forming part of this document. Fault level of panel shall be 50 KA.
All the MCCB up to 250 Amp shall have thermal release with adustable overload, short circuit & earth fault protection and above shall have microprocessor release with adjustable overload, short circuit & earthfault protection. The panel shall be manufactured as per BOQ, tech specification and drawing. Fault level of panel shall be 35 KA.
INCOMING
02 No. 800 Amp FP Electrically operated horizontal drawout type Air Circuit Breaker.
BUSCOUPLER
01 No. 800 Amp FP Electrically operated horizontal drawout type Air Circuit Breaker.
BUSBARS
1000 Amp TPN busbars of aluminium alloy as per SLD.
OUTGOING
EACH OUTGOING FEEDER SHALL HAVE DIGITAL ENERGY METER
5 Nos. 400 Amp FP Moulded Case Circuit Breaker.
8 Nos. 250 Amp FP Moulded Case Circuit Breaker.
INSTRUMENTS
2 No. 0 to 800 Amp digital ammeter (96mm square) with CT's.
2 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).
2 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).
2 Sets trip circuit healthy indicating lamp (one set for each incoming breaker).
2 Sets auto trip indicating lamp (one set for each incoming breaker).
2 Set of CT's one of 800/ 5Amp ratio for APFC relay.
2 Nos. Frequency meter (one for each Incoming Breaker).
2 Nos. master trip relay (one for each Incoming Breaker).
1 Set Electrical & Mechanical Interlocking between Incommer & Buscoupler.
BATTERY & BATTERY CHARGER
1 No. 24V, 72AH SMF Battery with suitable battery charger.
CAPACITOR BANK PANEL (175 KVAR) (ALL CAPACITOR PANEL SHALL BE PART OF MAIN L.T. PANEL) - 02 SET. (EACH CAPACITOR PANEL SHALL HAVE FOLLOWING)-
INCOMING
1 No. 0 to 400 Amp digital ammeter (96mm square) with CT's.
1 Sets of phase indicating lights (RYB) with protection fuses.
1 Sets breaker 'ON' & 'OFF' indicating lamp.
14 Step Automatic Power Factor Correction relay (APFC relay).
BUSBARS
500 Amp TPN busbars of aluminium alloy as per SLD.
OUTGOING
6 Nos. 63 Amp TP MCCB.
3 Nos. 32 Amp TP MCCB.
6 Nos. capacitor duty contactor (one for each 25KVAR capacitor unit).
3 Nos. capacitor duty contactor (one for each 10/5KVAR capacitor unit).
6 Nos. 25 KVAR Capacitor Bank.
3 Nos. 10/5 KVAR Capacitor Bank.
1 No. Indicating lamp for each 25/10/5 KVAR capacitor unit to indicate that the unit is 'ON'.
1 No. Toggle switch for changing automatic to manual operation of capacitor units.
Power factor meter.
Main L.T. Panel & Capacitor Panel describe as above
NURSE CALL SYSTEM (CONDUITING & WIRING ONLY)
LIFT WORK (FOR SADAR HOSPITAL ONLY)
LIFT - (MACHINE ROOM -NEW BLOCK)
Supplying, Installation, Testing and Commissioning of 20 Passenger - (1360 Kg) cum bed lift (gearless) having contract speed of 1.0 MPS and serving (G+4)= 5 stops in the lift shaft as per detailed specifications as under :-
Speed --> 1.0 MPS
Floors --> G+4
Travel --> 17.0 Mtrs Approx.
Stops & door opening - --> 5/1000 mm WideX 2100mm High
Controller: A.C. variable voltage & variable frequency drive.
Automatic rescue device complete with dry maintenance free batteries as required.
Power-415 V, 3 phase, 50 Hz, 4 wires system
Type of doors
(i) Car Power operated, Two Speed Stainless Steel hail line finish. (SS 304 Grade)
(ii) Landing doors : Stainless Steel hail line finish. (SS 304 Grade)
Hand rail not less than 600mm long at 900mm above floor level to be fixed on all the three sides adjacent to control panel in the lift car.
The Lift shall be provided with Brail System.
Ceiling as per manufacturer's standards with Fan & LED Lights.
On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE. Fire man switch at ground floor to be provided. Interlocking provision with Fire detection system shall be provided.
Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.
IP based CCTV interfaced to be provided.
BMS interface for lift position & 3 way Intercom system.
2 Hour Fire rated door. Manufacturer shall be submit the certificate alongwith supply of material from NABL approved Lab.
Lift described as above
LIFT - (MACHINE ROOM -NEW BLOCK)
Supplying, Installation, Testing & Commissioning of 13 Passenger (884 KG) Lift geared MR having contract speed of 1 MPS serving different floors in the lift shaft as per detailed specifications enclosed and as under:-
Speed --> 1.0 MPS
Floors --> G+4
Travel --> 17.0 Mtrs Approx.
Stops & door opening - --> 5/800 mm WideX 2100mm High
Controller: A.C. variable voltage & variable frequency drive.
Automatic rescue device complete with dry maintenance free batteries as required.
Power-415 V, 3 phase, 50 Hz, 4 wires system
Type of doors
(i) Car Power operated, Two Speed Stainless Steel hail line finish. (SS 304 Grade)
(ii) Landing doors : Stainless Steel hail line finish. (SS 304 Grade)
Hand rail not less than 600mm long at 900mm above floor level to be fixed on all the three sides adjacent to control panel in the lift car.
The Lift shall be provided with Brail System.
Ceiling as per manufacturer's standards with Fan & LED Lights.
On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE. Fire man switch at ground floor to be provided. Interlocking provision with Fire detection system shall be provided.
Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.
IP based CCTV interfaced to be provided.
BMS interface for lift position & 3 way Intercom system.
2 Hour Fire rated door. Manufacturer shall be submit the certificate alongwith supply of material from NABL approved Lab.
Lift described as above
PASSENGER LIFT - (MACHINE ROOM -LOUNDRY& CSSD BLOCK)
Supplying, Installation, Testing & Commissioning of 13 Passenger (884 KG) Lift geared MR having contract speed of 1 MPS serving different floors in the lift shaft as per detailed specifications enclosed and as under:-
Speed --> 1.0 MPS
Floors --> G+1
Travel --> 4.5 Mtrs Approx.
Stops & door opening - --> 2/800 mm WideX 2100mm High
Controller: A.C. variable voltage & variable frequency drive.
Automatic rescue device complete with dry maintenance free batteries as required.
Power-415 V, 3 phase, 50 Hz, 4 wires system
Type of doors
(i) Car Power operated, Two Speed Stainless Steel hail line finish. (SS 304 Grade)
(ii) Landing doors : Stainless Steel hail line finish. (SS 304 Grade)
Hand rail not less than 600mm long at 900mm above floor level to be fixed on all the three sides adjacent to control panel in the lift car.
The Lift shall be provided with Brail System.
Ceiling as per manufacturer's standards with Fan & LED Lights.
On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE. Fire man switch at ground floor to be provided. Interlocking provision with Fire detection system shall be provided.
Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.
IP based CCTV interfaced to be provided.
BMS interface for lift position & 3 way Intercom system.
2 Hour Fire rated door. Manufacturer shall be submit the certificate alongwith supply of material from NABL approved Lab.
Lift described as above
LIFT WORK (MEDICAL COLLEGE CAMPUS)
PASSENGER LIFT - AUDITORIUM BLOCK
Supplying, Installation, Testing & Commissioning of 16 Passenger (1080 KG) Lift geared MR / MRL having contract speed of 1 MPS serving different floors in the lift shaft as per detailed specifications enclosed and as under:-
Speed --> 1 MPS
Floors --> G+1
Travel --> 5.0 Mtrs Approx.
Stops & opening - --> 2/900 mm WideX 2100mm High
Controller: A.C. variable voltage & variable frequency drive.
Automatic rescue device complete with dry maintenance free batteries as required.
Power-415 V, 3 phase, 50 Hz, 4 wires system
Type of doors
(i) Car Power operated, Two Speed Stainless Steel hail line finish. (SS 304 Grade)
(ii) Landing doors : Stainless Steel hail line finish. (SS 304 Grade)
Hand rail not less than 600mm long at 900mm above floor level to be fixed on all the three sides adjacent to control panel in the lift car.
The Lift shall be provided with Brail System.
Ceiling as per manufacturer's standards with Fan & LED Lights.
On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE. Fire man switch at ground floor to be provided. Interlocking provision with Fire detection system shall be provided.
Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.
Cat6 wiring from Lift car to Lift machine room for IP based CCTV camera.
BMS connectivity for lift position & Intercom system.
Lift described as above
PASSENGER LIFT - GUEST HOUSE BLOCK
Supplying, Installation, Testing & Commissioning of 13 Passenger (884 KG) Lift geared MR / MRL having contract speed of 1 MPS serving different floors in the lift shaft as per detailed specifications enclosed and as under:-
Speed --> 1 MPS
Floors --> G+3
Travel --> 10.0 Mtrs Approx.
Stops & opening --> 4/800 mm WideX 2100mm High
Controller: A.C. variable voltage & variable frequency drive.
Automatic rescue device complete with dry maintenance free batteries as required.
Power-415 V, 3 phase, 50 Hz, 4 wires system
Type of doors
(i) Car Power operated, Two Speed Stainless Steel hail line finish. (SS 304 Grade)
(ii) Landing doors : Stainless Steel hail line finish. (SS 304 Grade)
Hand rail not less than 600mm long at 900mm above floor level to be fixed on all the three sides adjacent to control panel in the lift car.
The Lift shall be provided with Brail System.
Ceiling as per manufacturer's standards with Fan & LED Lights.
On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE. Fire man switch at ground floor to be provided. Interlocking provision with Fire detection system shall be provided.
Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.
Cat6 wiring from Lift car to Lift machine room for IP based CCTV camera.
BMS connectivity for lift position & Intercom system.
Lift described as above
PASSENGER LIFT - GIRLS & BOYS HOSTEL BLOCK
Supplying, Installation, Testing & Commissioning of 8 Passenger (544 KG) Lift geared MR / MRL having contract speed of 1 MPS serving different floors in the lift shaft as per detailed specifications enclosed and as under:-
Speed --> 1 MPS
Floors --> G+7
Travel --> 21.0 Mtrs Approx.
Stops & opening --> 8/800 mm WideX 2100mm High
Controller: A.C. variable voltage & variable frequency drive.
Automatic rescue device complete with dry maintenance free batteries as required.
Power-415 V, 3 phase, 50 Hz, 4 wires system
Type of doors
(i) Car Power operated, Two Speed Stainless Steel hail line finish. (SS 304 Grade)
(ii) Landing doors : Stainless Steel hail line finish. (SS 304 Grade)
Hand rail not less than 600mm long at 900mm above floor level to be fixed on all the three sides adjacent to control panel in the lift car.
The Lift shall be provided with Brail System.
Ceiling as per manufacturer's standards with Fan & LED Lights.
On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE. Fire man switch at ground floor to be provided. Interlocking provision with Fire detection system shall be provided.
Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.
Cat6 wiring from Lift car to Lift machine room for IP based CCTV camera.
BMS connectivity for lift position & Intercom system.
Lift described as above
PASSENGER LIFT - TYPE-IV & TYPE-III RESIDENCE BLOCK
Supplying, Installation, Testing & Commissioning of 13 Passenger (884 KG) Lift geared MR / MRL having contract speed of 1 MPS serving different floors in the lift shaft as per detailed specifications enclosed and as under:-
Speed --> 1 MPS
Floors --> S+8
Travel --> 24.0 Mtrs Approx.
Stops & opening --> 9/900 mm WideX 2100mm High
Controller: A.C. variable voltage & variable frequency drive.
Automatic rescue device complete with dry maintenance free batteries as required.
Power-415 V, 3 phase, 50 Hz, 4 wires system
Type of doors
(i) Car Power operated, Two Speed Stainless Steel hail line finish. (SS 304 Grade)
(ii) Landing doors : Stainless Steel hail line finish. (SS 304 Grade)
Hand rail not less than 600mm long at 900mm above floor level to be fixed on all the three sides adjacent to control panel in the lift car.
The Lift shall be provided with Brail System.
Ceiling as per manufacturer's standards with Fan & LED Lights.
On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE. Fire man switch at ground floor to be provided. Interlocking provision with Fire detection system shall be provided.
Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.
Cat6 wiring from Lift car to Lift machine room for IP based CCTV camera.
BMS connectivity for lift position & Intercom system.
Lift described as above
PASSENGER LIFT - TYPE-V RESIDENCE BLOCK
Supplying, Installation, Testing & Commissioning of 13 Passenger (884 KG) Lift geared MR / MRL having contract speed of 1 MPS serving different floors in the lift shaft as per detailed specifications enclosed and as under:-
Speed --> 1 MPS
Floors --> S+4
Travel --> 12.0 Mtrs Approx.
Stops & opening --> 5/900 mm WideX 2100mm High
Controller: A.C. variable voltage & variable frequency drive.
Automatic rescue device complete with dry maintenance free batteries as required.
Power-415 V, 3 phase, 50 Hz, 4 wires system
Type of doors
(i) Car Power operated, Two Speed Stainless Steel hail line finish. (SS 304 Grade)
(ii) Landing doors : Stainless Steel hail line finish. (SS 304 Grade)
Hand rail not less than 600mm long at 900mm above floor level to be fixed on all the three sides adjacent to control panel in the lift car.
The Lift shall be provided with Brail System.
Ceiling as per manufacturer's standards with Fan & LED Lights.
On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE. Fire man switch at ground floor to be provided. Interlocking provision with Fire detection system shall be provided.
Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.
Cat6 wiring from Lift car to Lift machine room for IP based CCTV camera.
BMS connectivity for lift position & Intercom system.
Lift described as above
PASSENGER LIFT - MEDICAL COLLEGE BLOCK (2 NO LIFT SHALL BE USED AS FIRE LIFT)
Supplying, Installation, Testing & Commissioning of 13 Passenger (884 KG) Lift geared MR / MRL having contract speed of 1 MPS serving different floors in the lift shaft as per detailed specifications enclosed and as under:-
Speed --> 1 MPS
Floors --> G+5
Travel --> 20.0 Mtrs Approx.
Stops & opening --> 6/800 mm WideX 2100mm High
Controller: A.C. variable voltage & variable frequency drive.
Automatic rescue device complete with dry maintenance free batteries as required.
Power-415 V, 3 phase, 50 Hz, 4 wires system
Type of doors
(i) Car Power operated, Two Speed Stainless Steel hail line finish. (SS 304 Grade)
(ii) Landing doors : Stainless Steel hail line finish. (SS 304 Grade)
Hand rail not less than 600mm long at 900mm above floor level to be fixed on all the three sides adjacent to control panel in the lift car.
The Lift shall be provided with Brail System.
Ceiling as per manufacturer's standards with Fan & LED Lights.
On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE. Fire man switch at ground floor to be provided. Interlocking provision with Fire detection system shall be provided.
Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.
Cat6 wiring from Lift car to Lift machine room for IP based CCTV camera.
BMS connectivity for lift position & Intercom system.
Lift described as above
HVAC WORKS
ARI Certified Rotary Screw Water Cooled Chilling Machine With Air Cooled VFD & Microprocessor Based Control Panel (Capacity - 300 TR)
Supply, installation, testing and commissioning of Rotary Screw Water cooled water Chilling M/C of 300 TR actual capacity at below mentioned operating conditions with R - 134 A refrigerant, open / semihermatic / hermatically sealed compressor, driven by suitable KW Sq. Cage induction motor complete with variable speed drive complete with watercooled shell & tube condenser, insulated shell and tube flooded chiller, flow switches at condenser & chiller outlet, refrigerant piping, Refrigerant and Oil (First Charge), Microprocessor based control panel, chiller mounted aircooled VSD with IP 54 enclosure, active harmonic filters (THDI less than 5%), Anti-vibration isolators mountings as per mfgs recommendations, flexible pipe connector at condenser & chiller inlet / outlet, & accessories etc. all mounted on M.S. frame. Motor shall be suitable for 415 volts ± 10%, 50Hz ± 5 %, three phase A.C. supply. The chilling m/c as described above shall be in line with specifications & shall have interface card compatible with BMS system. Actual capacity of chillers shall be based the parameters given below & power consumption / TR at 100%, 75%, 50% & 25% load shall be based on AHRI Condition.
Condenser CDW IN - 32.22º C.
CDW OUT - 36.38º C.
FLOW - 4536 LPM
Fouling Factor (MKS) - 0.0002
Pressure Drop Max - 6.5 Meter
Chiller CHW IN - 12.22º C.
CHW OUT - 6.67º C.
FLOW - 2721 LPM
Fouling Factor (MKS) - 0.0001
Pressure Drop Max - 6.5 Meter
COP At AHRI Condition - 5.8 (Min)
Power Consumption Of Chiller / TR At Tender Condition Mentioned Above (Max) - 0.68
The price quoted for supply, installation, testing & commissioning of Rotary Screw Water Chilling Unit shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. as required in Indian Rupees. (1W+1S)
Condenser Water Pumps Set
Supply, installation, testing and commissioning of Vertical Inline condenser water centrifugal pump sets with bronze impeller for condenser water recirculation complete with TEFC (IE3) Sq. Cage induction motor with class "F" insulation, base plate, coupling guard, SS Shaft Grade 316, bronze impeller, factory fitted mechanical seal, flexible pipe connector at inlet and outlet etc. conforming to technical specification & as per following parameters.
Condenser Water Pumps Set (1W+1S)
Capacity of Each Pump LPM 4536
Pump Head (Mt) 25.0
Motor HP (Indicative Only) 40.0
Pump Efficiency (Min) 80%
Primary Chilled Water Pumps Set
Supply, installation, testing and commissioning of Vertical Inline chilled water centrifugal pump sets with bronze impeller for chilled water recirculation complete with TEFC (IE3) Sq. Cage induction motor with class "F" insulation, base plate, coupling guard, SS Shaft Grade 316, bronze impeller, factory fitted mechanical seal, flexible pipe connector at inlet and outlet etc. conforming to technical specification & as per following parameters. The chilled water pumps shall also include the cost of thermal insulation.
Primary Chilled Water Pumps Set (1W+1S)
Capacity of Each Pump LPM 2721
Pump Head (Mt) 12.00
Motor HP (Indicative Only) 12.5
Pump Efficiency (Min) 75%
Secondary Chilled Water Pumps Set
Supply, installation, testing and commissioning of Vertical Inline chilled water centrifugal pump sets with bronze impeller for chilled water recirculation complete with TEFC (IE3) Sq. Cage induction motor with class "F" insulation, base plate, couplingguard, SS Shaft Grade 316, bronze impeller, factory fitted mechanical seal, flexible pipe connector at inlet and outlet etc. conforming to technical specification & as per following parameters. The chilled water pumps shall also include the cost of thermal insulation. Secondary chilled water pumps shall be suitable for operation on variable frequency drives & conforming to the specifications of variable speed pumping system.
For Medical College & Auditorium Building
Secondary Chilled Water Pumps Set (1W+1S)
Capacity of Each Pump LPM 2721
Pump Head (Mt) 18
Pump Motor HP (Indicative Only) 15
Pump Efficiency (Min) 80%
Variable Speed Pumping System for Secondary Chilled Water Pumps
Supply, installation, testing and commissioning of Variable Speed Pumping system consisting of two numbers 15 / 20 HP variable frequency drive (VFD) having IP-54/55 enclosure with heat sink suitably interfaced with other system components, hand / auto macro designed for pumping application, 01 no. dedicated microprocessor based pump logic controller, parallel pumping software duly downloaded, 02 No. Differential Pressure Sensor / Transmitters, interfacing amongst all components and compatibility of I/O signals etc complete with other accessories as required.
CTI Certified FRP Induced Draft Cooling Tower (300 TR / 11,34,000 Kcal/Hr)
Supply, installation, testing and commissioning of FRP Induced draft, cross / counter flow, twin fan, direct driven, site erected cooling tower of capacity as mentioned below based on the parameters given below and complete with PVC Fill, Louvers, Drift Eliminator, Weather Proof IP 55 TEFC Motor (IE3), Propeller Fan, FRP Basin with additional sump in the bottom of the basin on every outlet point to avoid vortex formation in the condenser water pipe line, Hot dip galvanised Steel Ladder, Stainless Steel hardware including nut, bolt, washer etc. The cooling tower shall conform to technical specifications given in the tender. The maximum allowable sound power at a distance of 1 M from the cooling Tower shall be less than 75 dB. Tower fan motor shall be suitable for VFD operation and operation of VFD system shall be based approach of cooling tower.
Performance required for cooling tower is minimum 38.2 gpm/hp.
Water Flow - 4536 LPM (4 GPM / TR)
Designed Wet Bulb Temperature - 28.3 °C
Water Inlet / Outlet Temperature - 36.38 °C / 32.22 °C
Cooling Tower Basin Height - 300.0 MM
Fan Motor HP - 2 x 10 / 7.5 HP, 960 RPM
Cooling Tower Capacity: 11,34,000 Kcal/Hr, 1W+1S
VFD System For Cooling Tower
Supply, installation, testing and commissioning of VFD having IP-54/55 enclosure from factory with heat sink for each cooling tower fan (10 / 7.5 HP Each, 4 Nos.) with VFD control panel & other accessories as required. VFD control panel shall be installed in the AC Plant Room. The system shall be complete with variable frequency drive (VFD) suitably interfaced with other system components, hand / auto macro designed, 01 no. dedicated microprocessor based logic controller, software duly downloaded, tempearture Sensor / Transmitters, interfacing amongst all components and compatibility of I/O signals etc complete with other accessories as required. Operation of VFD system shall be based approach of cooling tower.
Pressurised Expansion Tank & Degassing Unit (Suitable for 300 TR & Water Volume as per acual piping layout)
The system shall consist of following : a)Pressurization Unit with vacuum degasser c/w Pumps,vacuum cylinder, Break tank, float valve, over flow connection, pressure sensor for system and for vacuum cylinder, solenoid valve, safety relief valve, isolation Valve, NRV, Drain Valve, flood protection in the event of a serious leak, Pipe fittings c/w Controller & display, full unit duly tested, housed in a mild steel cabinet. b)Pressurized Expansion Tank 800 liter c/w high quality butyl rubber bladder, Nitrogen filling for longer maintenance of pre pressurization• The pressurized expansion tank shall be cylindrical, In accordance with Pressure Equipment Directive 2014/68/EU. Tanks from (100 - 1000 liters): in accordance with EN13831 & from 1200 - 8000 liters: in accordance with AD2000. c)Controller for both pressurization and vacuum degassing function with LED display scrolling messages including pump operation and alarm mode etc.
Hot Water Generator For Winter Heating
Supply, installation, testing and commissioning of electrically operated Hot Water Generator of capacity 240 KW in multiple bank complete with PLC based microprocessor controls, electrical panels etc. confirming to technical specifications section. (1W+1S)
Inlet Water Temperature 50 °C
Outlet Water Temperature 55 °C
Double Skin AHU (CC + Pre Filter)
Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 6 row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.) and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities.
Fan Coil Unit (CC)
The complete fan coil unit shall have acoustically lined casing & shall be in line with the tender specification. The capacity of fan coil units shall be as follows. The FCU shall be with one set of commissioning filter which shall be replaced with actual filter.
1.5 TR, 4 mm external static
2.0 TR, 5 mm external static
2.5 TR, 5 mm external static
3.0 TR, 8 mm external static
3.5 TR, 8 mm external static
4.0 TR, 8 mm external static
FCU Valves With Three Way Bypass Flushing Unit Set For Cooling / Heating Coil
Supply, installation, testing and commissioning of factory insulated jacket copper / brass connection set for chilled water line consisting of Pressure Independant Balancing Cum Two Way Control Valve in a single body equipped with electronic modulating actuator working on 2-10 V DC, 4- 20 mA electric signal, ball valve with strainer at inlet, ball valve at outlet, three way bypass flushing unit, copper / brass connection set with braided pipe flexible connector at in and out at one end etc. Ball valves & strainer sizes in cooling coil shall be 25 mm up to 2 TR & 32 mm for 2.5 TR & above. PIBCV valves sizes in cooling coil shall be 20 mm up to 2 TR & 25 mm for 2.5 TR, 32 mm for 3.0 TR & above.
Thermostat for FCU
Supply, installation, testing and commissioning of automatic control for Fan Coil Units for cooling / heating consisting of pressure independant balancing cum two way control valve (already quantified herein) & digital thermostat, which will have provision of setting of room temperature, setting of fan speed (High, Medium, Low). The quoted price of thermostat shall include the cost of 20mm MS conduits, control cabling, MS Box etc as required. Thermostats shall be interlocked to prevent simultaneous heating and cooling.
Digital Display Type Thermostat For AHU
Supply, installation, testing and commissioning of Proportional cooling / heating, digital display, communicating type thermostat at air-handler. Temperature Sensor for AHUs are also specified in BMS Part. Thermostat shall be installed in case BMS commissioning is significantly delayed.
Inline Fans
100 - 200 CFM (8mm static pressure, single phase)
300 CFM (8mm static pressure, single phase)
400 CFM (10mm static pressure, single phase)
500 CFM (10mm static pressure, single phase)
600 CFM (10mm static pressure, single phase)
700 CFM (10mm static pressure, single phase)
800 CFM (12mm static pressure, single phase)
900 CFM (12mm static pressure, single phase)
1000 CFM (15mm static pressure, single phase)
1300 CFM (15mm static pressure, single phase)
Plastic Propeller Fans
Supply, installation, testing and commissioning of propeller exhaust fans of various capacities as given below suitable for 240 volts, 50 Hz, single phase AC supply complete with gravity louvers & speed regulator etc.
Axial Flow Fan For Lift Well, Lobby & Staircase Pressurisation, Fresh Air & Exhaust Air Ventilation etc.
Axial Fan shall be AMCA certified for Air and Sound performance in accordance to AMCA 210 and AMCA 300. Complete certified model appearing on AMCA web site shall be accepted. Complete Fan shall be tested and approved by UL in accordance with "Power Ventilators for Smoke Control Systems" for 250 °C for 2 hours.
Manufacturer shall furnish AMCA Test Certificate for air & sound performance along with UL fire test certificate (Latest) for each fan sourced from that particular factory.
15,000 CFM (20mm st. pr, 800 mm Dia Axial Fan, 3.7 KW Or As Required, 1450 RPM Fan Motor, Direct Driven)
12,000 CFM (25mm st. pr, 800 mm Dia Axial Fan, 3.7 KW, 1450 RPM Fan Motor, Direct Driven)
10,000 CFM (20mm st. pr, 800 mm Dia Axial Fan, 2.2 KW, 1450 RPM Fan Motor, Direct Driven)
8,000 CFM (20mm st. pr, 700 mm Dia Axial Fan, 2.2 KW, 1450 RPM Fan Motor, Direct Driven)
2,500 CFM (20mm st. pr, 355 mm Dia Axial Fan, 0.75 KW, 1450 RPM Fan Motor, Direct Driven)
2,000 CFM (20mm st. pr, 355 mm Dia Axial Fan, 0.75 KW, 1450 RPM Fan Motor, Direct Driven)
Factory Fabricated Double Skin Airwasher
Supply, installation, testing and commissioning of factory fabricated Double Skinned Air-washer unit floor mounted type fabricated out of extruded aluminium section with 0.6mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.6 mm plain Galvanised steel sheet inside with blower, blower section and blower motor TEFC (Motor Efficiency IE3) type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, belt drive package, wet section & tank shall be made of 18 G stainless steel.
The Air-washer shall be complete with fill of depth 200 mm & face velocity across the fill shall be limited to 152 MPM. The Air-washer shall have an efficiency of 90% & shall be complete with water circulation pump GI B Class interconnecting piping & valves Aluminum viscous filters. The Air-washer shall have an efficiency of 90% & shall be complete with water circulation pump GI B Class interconnecting piping & valves Aluminum viscous filters. The airwasher panels shall be insulated with 23mm thick & 36 Kg/m³ density PU foam. The Airwasher shall conform to specication given in the tender & shall be of following capacity.
15,000 CFM, 1 x 710 mm Dia. Fan, 1 x 7.5 Kw Fan Motor, 50 mm St. Pressure, Monoblock Pump
Centrifugal Fan
Supply, installation, testing and commissioning of DIDW centrifugal fan, GI construction. The fan shall be suitable for V belt drive arrangement & in bare shaft construction. The fan impeller shall have backward curved blades suitable for handling air. The centrifugal fan motor shall be suitable for single speed TEFC (Motor Efficiency IE3) squirrel cage induction motor suitable for 415 415 volts ± 10%, 50Hz ± 5 %, three phase AC power supply motor with class "H" insulation, Fire resistant V belt drive set comprising of fan & motor pullys & one set of belts, slide rails, MS / GI belt protection, fire rated convass connection at outlet side, multilouvers damper at outlet side in GI construction with casing in 16 G & louvers in 18 G construction, foundation bolts, common base frame in standard MS construction, anti vibration mountings arrangement. The fan capacity shall be as follows:-
12,000 CFM, 25mm st. pr, 630 mm Dia Fan, 10.0 HP, 1440 RPM Fan Motor, Belt Driven
Valves & Strainer
Supply, installation, testing and commissioning of following valves in chilled / hot water line as per specification given in the tender. Valves shall be insulated as per pipe insulation material & thickness given above.
Globe Valves
19 mm dia
25 mm dia
32 mm dia
40 mm dia
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.
32 mm dia
Condensate Drain Piping With Nitrile Rubber Insulation
Supply, installation, testing and commissioning of condensate drain water piping of GI 'Medium' class complete with fittings like elbows, tees, reducers, bends, MS flanges, supports, welding, painting etc. as required conforming to tender specifications and of following sizes. Complete pipe shall be duly insulated with Closed Cell Elastomeric Nitrile Rubber of specified pipe section of specified thickness in the tender specification & suitable for indoor / outdoor application. Complete pipe insulation shall also have 200 g/m² factory laminated, treated woven Glass Cloth coating for mechanical and UV protection.
25 mm dia pipe, 13 mm Insulation
32 mm dia pipe, 13 mm Insulation
40 mm dia pipe, 13 mm Insulation
50 mm dia pipe , 19 mm Insulation
65 mm dia pipe, 19 mm Insulation
Auto Air Vent
Supply, installation, testing and commissioning of auto air vent valve of following sizes and complying with tender specification.
a) 10 mm dia auto air vent valve
c) 25 mm dia auto air vent valve
Burried Chilled / Hot Water Piping With TF Quality Expanded Polysterene Insulation & Sand Cement Plaster
Supplying, laying / fixing, testing and commissioning of following nominal sizes of chilled / hot water piping outside the building laid in the ground including earth excavation & filling as required (with necessary clamps and fittings but excluding valves, strainers, gauges etc.) duly insulated with following thickness TF Quality Expanded Polysterene of minimum 20 Kg / m3 density, thermal conductivity 0.035 (K.cal/ hr. degree C/m or better at 10 deg mean temperature covered with 500 gauge polythene faced hessian with 50 mm overlap, All joints sealed with bitumen, A layer of 0.50 mm x 20 mm G.I. wire mesh netting provided over it butting all joints and laced down with GI wire, sand cement plaster (1:4) 20 mm. thick provided in 2 layers of each 10mm and water proofed by applying hot bitumen & fixing tar felt over the plaster as per specifications and as required complete in all respect.
Note:-The Pipes of sizes 150 mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
250 mm dia. (75 mm thick insulation)
150 mm dia. (50 mm thick insulation)
125 mm dia. (50 mm thick insulation)
Condenser Water Piping
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends, tees etc..but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect.
Note:-The Pipes size 150 mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
50 mm dia pipe
Manual Balancing Valves
Supply, installation, testing and commissioning of manual balancing valves in return chilled and condenser water line of each chiller, condenser and cooling tower as per tender specification & of following sizes:
250 mm dia (For Condenser Out, Cooling Tower In)
Valves & Strainer
Supply, installation, testing and commissioning of following valves in chilled / condenser water line as per specification given in the tender.
BUTTERFLY VALVE (MANUAL) with CI body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified.
250 mm dia
300 mm dia
NON - RETURN VALVE with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified.
250 mm dia
Pot Strainer
Supply, installation, testing and commissioning of PN 16 rating Pot - Strainer of the following sizes confirming to tender specification.
a) 300 mm dia
Site Fabricated Aluminium Ducting
Supply, fabrication, installation & testing of Aluminium sheet metal ducting duly polysulphide sealed complete with Spliter Damper, vanes etc. as required for OT and as per ISI specifications and as per approved shop drawings.
Duct Insulation
Supplying and fixing of external thermal insulation on ducts with Aluminium Metalized Cross Linked Closed Cell Polyethylene FR-XPE insulation, tape & adhesive (pidilite SR -998) as required of following thickness.
Grilles, Diffusers, VCD
Supply, installtion and testing of Powder coated Aluminium extruded grills / diffusers as per specifications given in tender and of following sizes.
Fresh / Exhaust air louvers with bird screen & damper
Volume control GI Dampers to be provided in supply & Exhaust air registers / terminals.
Fixed bar linear air register of following sizes
Slot linear air diffusers of following sizes:
Under Deck Insulation of Exposed Roof
Supplying and fixing of thermal insulation on exposed roof (underdeck) with 13mm thick Cross Linked Closed Cell Polyethylene FR-XPE insulation of density 33 Kg/m³ with adhesive (pidilite SR -998) etc. as required & finally fixed with the help of rawl plug & dash fasteners in ceiling.
Main AC Panel
a) Screw Chiller, 300 TR (1W+1S), 204 Kw Each with VFD - Both Chiller along with pumps also can operate in case of Medical College working with Auditorium
b) CHW Pr. Pump for Chiller, 12.5 HP Each, (1W+1S)
c) CDW Pump for Chiller, 40.0 HP Each, (1W+1S)
d) Zone I - CHW Sr. Pump - 15.0 HP Each, (1W+1S)
e) Cooling Tower Fan Motor, 4 x 7.5 / 10 HP (2W+2S)
f) HWG 240 Kw, Winter Heating (1W+1S)
Supply, installation, testing and commissioning of Cubical type sectinalised floor standing switch board by CPRI apprved firms of 31 MVA fault capacity at 415 V complete with 4 strip, 1600 A capacity Aluminium Bus - Bar Electrolytic grade E-91, cable alley, switchgears suitable for AC-23 duty & of following capacity & as per specification given in the tender.
a) Incomer
Outgoings
a) For 2 Nos. Water-cooled Chilling Machine (1W+1S) with VFD
b) For 2 Nos. 12.5 HP Pr. CHW Pumps for Chiller (1W+1S)
c) For 2 Nos. 40 HP CDW Pumps for Chiller (1W+1S)
d) For Zone I - 2 Nos. 15 HP Sr. CHW Variable Speed Pumps
40 A TPN MCB & BMS compitable electronic KWH meter SET-02
e) For 4 Nos. 10 HP CT Fan Variable Speed Motor (2W+2S)
32 A TPN MCB & BMS compitable electronic KWH meter SET-8
f) For 2 Nos. Hot Water Generator (1W+1S)
400 A 4 Pole MCCB. SET - 02
Controls & interlocking accessories as required. Lot
Electrical Sub Panel for AHU / FAN / AWS / Scrubber
Supply, installation, testing and commissioning of Cubical wall mounted type switch board as detailed below & switch gears suitable for AC - 23 duty including making interconnection etc as required. BMS compitable electronic KWH meter shall have been taken in main electrical work therefore same shall not be part of followings sub panel.
For AHU / Vent Fan Motor Up to 3.73 Kw
Controls & interlocking accessories as required. Lot
For AHU / Vent Fan Motor of 5.6 Kw
Controls & interlocking accessories as required. Lot
For AHU / Vent Fan Motor of 7.5 Kw
Controls & interlocking accessories as required. Lot
For AHU / Vent Fan Motor of 9.3 / 11 Kw
Controls & interlocking accessories as required. Lot
For Fan Motor, 1 x 15 Kw Air Washer + 1 x 7.5 Kw Centrifugal Fan For AC Plant Room Ventilation
Supply, installation, testing and commissioning of Cubical type sectinalised floor standing switch board by CPRI apprved firms of 18 MVA fault capacity at 415 V complete with 4 strip, 125 A capacity Aluminium Bus - Bar Electrolytic grade E-91, cable alley, switchgears suitable for AC-23 duty & of following capacity & as per specification given in the tender.
Incomer
Outgoing
a) For Air-washer Fan Motor of 1 x 15 Kw
b) For Air Washer Pump
16 A SP MCB, SET-1
c) For Fan Motor of 7.5 Kw
Controls & interlocking accessories as required. Lot
M.C.C. For 18 To 26 HP VRV Outdoor Units (Panel Suitable For Outdoor Type - IP54), Location Near ODU
Supply, installation, testing and commissioning of Cubical type sectinalised floor standing switch board by CPRI apprved firms of 31 MVA fault capacity at 415 V complete with 4 strip, 125 A capacity Aluminium Bus - Bar Electrolytic grade E-91, cable alley, switchgears suitable for AC-23 duty & of following capacity & as per specification given in the tender.
a) INCOMER
OUTGOINGS
i) For VRV ODU
63 A TPN MCB (1W+1S) SET 02
ii) For VRV AHU
40 A TPN MCB for VRV AHU (1W+1S) SET 02
Controls & interlocking accessories as required. LOT
M.C.C. For 28 To 34 HP VRV Outdoor Units / AHU (Panel Suitable For Outdoor Type - IP54), Location Near ODU / AHU
Supply, installation, testing and commissioning of Cubical type sectinalised floor standing switch board by CPRI apprved firms of 31 MVA fault capacity at 415 V complete with 4 strip, 160 / 200 A capacity Aluminium Bus - Bar Electrolytic grade E-91, cable alley, switchgears suitable for AC-23 duty & of following capacity & as per specification given in the tender.
a) INCOMER
OUTGOINGS
i) For VRV ODU
63 A TPN MCB (2W+1S) SET 03
ii) For VRV AHU
40 A TPN MCB for VRV AHU (1W+1S) SET 02
Controls & interlocking accessories as required. LOT
OT AHU (1 x 5 HP + 1 x 1 .5 HP + 3 KW Humidifier + (3+3) KW Strip Heater
INCOMER
OUTGOING
For AHU Fan Motor
For Exhaust Fan Motor
For Humidification Package
For Strip Heater
Controls & interlocking accessories as required. LOT
ICU AHU (1 x 3 HP +1.5 KW Humidifier)
INCOMER
OUTGOING
For AHU Fan Motor
For Humidification Package
Single Phase MCB for FCU / Inline Fan
Supply, Installation, testing & Commissioning of single phase MCB of following capacity:
16 A SP MCB, SET-01
Isolators
40 A 6 pole isolator switch with sheet metal enclosure, rain protection etc. as required to suit the site condition.
63 A 6 pole isolator switch with sheet metal enclosure, rain protection etc. as required to suit the site condition.
40 A 3 pole isolator switch with sheet metal enclosure, rain protection etc. as required to suit the site condition.
Power & Control Cabling
Aluminium Conductor Armoured Cables
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. Power cabling of XLPE insulated Aluminium conductor armoured cables of 1.1 KV Grade including cable end termination with brass compression glands & aluminium lugs etc as per specification.
Power Cabling
For Chiller (204 Kw Each)
2 x 3.5C x 240 Sq. mm (Rate For Single Run)
For CHW Pump, Cooling Tower Fan (12.5 & 10 HP Each)
2 x 3C x 6 Sq. mm (Rate For Single Run)
For CDW Pump (40 HP Each)
2 x 3C x 35 Sq. mm (Rate For Single Run)
For HW Pump (7.5 HP Each)
1 x 3C x 6 Sq. mm (Rate For Single Run)
For Hot Water Generator (240 Kw Each)
2 x 4C x 185 Sq. mm (Rate For Single Run)
For Motor Up to 3.73 Kw
1 x 3C x 4 Sq. mm
For Motor of 5.5 Kw
1 x 3C x 6 Sq. mm
For Motor of 7.5 to 11 Kw
2 x 3C x 6 Sq. mm
For Motor of 15.0 Kw
For Motor of 22.5 Kw
1 x 3C x 2.5 Sq. mm Copper
3C x 10 Sq. mm Al Conductor (Armoured) For AHU & Vent Fan
Copper Conductor (Unarmoured)
4C x 25 Sq. mm Copper Conductor (Unarmoured) For VRF Unit
4C x 16 Sq. mm Copper Conductor (Unarmoured) For VRF Unit
B) Control cabling (PVC insulated Copper conductor of 1.1 KV Grade armoured cable)
3C x 1.5 Sq. mm
4C x 1.5 Sq. mm
5C x 1.5 Sq. mm
For VRV Indoor Units (Cable shall be laid running in the PVC conduit through wall & ceiling along with the approved route. AC Contractor shall include the cost of chiselling & finishing the wall / ceiling. Cable from ODU electrical feeder panel shall run along with refrigerant piping on common cable tray)
3C x 6 Sq. mm Copper Conductor (PVC insulated, PVC sheathed flexible wire)
3C x 4 Sq. mm Copper Conductor (PVC insulated, PVC sheathed flexible wire)
3C x 2.5 Sq. mm Copper Conductor (PVC insulated, PVC sheathed flexible wire)
Communication & Signal Cabling
Providing & fixing of Communication & Signal Cabling 2C x 1.5 Sq. mm Shielded Tinned Copper Cable.
MS Conduit 25 mm for Signal & Communication Cable
Earthing Strip / Wires as per specs.
Supply & laying of 32 x 6 mm GI strip recess / surface as strip earth lead including soldering etc. as required.
Supply & laying of 25 x 6 mm GI strip recess / surface as strip earth lead including soldering etc. as required.
Supply & laying of 4 SWG GI wire or in recess for loop earthing as required.
Supply & laying of 6 SWG GI wire or in recess for loop earthing as required.
Supply & laying of 10 SWG GI wire or in recess for loop earthing as required.
Supply and fixing rubber matting conforming to IS-15652-2006 complete etc. as required.
Cable Tray
Fabricating and installing following size of perforated M.S. Cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders and including painting with powder coating etc as required.
100 mm wide x 50 mm x 1.6 mm
150 mm wide x 50 mm x 1.6 mm
300 mm wide x 50 mm x 1.6 mm
450 mm wide x 50 mm x 2 mm
600 mm wide x 50 mm x 2 mm
Junction Box For FCU / Propeller / Inline Fan etc (Single Phase)
Supply, Installation, Testing & Commissioning of 4" x 3" x 3" G.I. Box with modular type 6A socket & switch, modular cover plate etc as required at site.
Starter for Propeller / Inline fan (Single Phase)
Supply, Installation, Testing & Commissioning of modular type single phase motor starter up to 6A (Rating shall be as per motor) including 3" x 3" x 2.5" G.I. Box with modular, modular cover plate, conduiting and wiring from starter to fan etc as required at site.
All the items listed below shall include supply, installation, testing & commissioning.
Software and Operator Workstation
Host PC comprising core i7 processor or later, 3 GHz, 8.0 GB RAM, 1 TB HDD, DVD drive, 6 nos. USB Port, 18.5" SVGA color flat TFT monitor, keyboard, mouse and pre-loaded windows 8 operating system and anti virus software, Laserjet printer (A4 size, B/W)
Supply, installation, testing & commissioning of the following Web Based graphical Software. Providing facilities to create static & animate the graphics, navigation between the pages, display of logs, changing the time zones, popup alarms with single user license & point capacity as per I-O Summary with 20% spare points configurable password protection for the system and should be able to communicate with BACnet/M-BUS/LONWORK & MODBUS devices simultaneously. This software will act as web server & no additional license should require at client side.
Application Software for Building Automation System having facility to to exchange information using SQL database. Software shall have the features to calculate the total power consumption, total refrigeration load consumed on every day etc. Critical alarms generated in a day and its status should also be mailed along with daily report.
Supervisory Controllers
Network Area / Supervisory Controller for Building Management System (BMS). Network Area Controller Shall support Communication with AC Plant Controllers (DDC controllers) & Other Application Controllers on BACnet, Shall support Communication with Integrator Units as defined below on BACnet / MODBUS / LONWORKS. Router must be compliant with ANSI / ASHRAE 135-2012 (Rev. 1.10)
Direct Digital Controllers (BACNET / LON Type)
Stand alone, intelligent, UL Listed, BTL listed & BTL tested, ANSI / ASHRAE approved Interoperable DDC as per the specifications. All the Controllers shall be UL / BTL tested & CE certified. Each controllers shall be equipped with Universal Inputs with a maximum polling speed of 100 ms. DDC Controller shall have a resident real time clock with a battery back up. DDC must support trending & scheduling at Controller level.The controller shall be housed in a vandal proof, lockable and secure MS cabinets to be supplied along with controllers. DDC must match BACnet profile B-BC (Building Controller) / B-AAC Profile as per BTL listing. The controller shall have 15% Extra IO capacity.
For Chilled water system - Chillers, CHW & CDW Pumps, Cooling Towers, HWG, HW Pumps & Headers etc. as required.
For Air Handling Units (Category A) as per IO Summary as required. (2 Nos. AHU with 1 No. DDC)
For All 3 Phase Fans - Fresh Air / Exhaust Air Fan, Airwasher, Scrubber, Pressurisation Fan etc. as required. (4 No. Fans with 1 No. DDC)
For Lift Well, Lift Lobby & Staicase Pressurisation Fans (4 Nos. Fans with 1 No. DDC)
Field instruments As Per I-O Summary
Immersion Temperature sensor with thermowell for Chilled water system (4 Nos. Chiller Outlet, 2 Nos. Chilled Water Header, 1 No. Condenser Water Return Header, 3 Nos. Hot Water Generator Outlet, 2 Nos. Hot Water Header)
Ambient air temperature and humidity sensor
Current relay for pumps (4 Nos. Primary CHW Pumps, 4 Nos. CDW Pumps, Excluding Pumps on VFD)
Differential pressure switch for various vent. fans excluding Inline & Propeller Fans
Differential pressure switch for AHU blower status
Differential pressure switch AHU Pre, Fine & Hepa Filter status
Temperature sensor for return temperature monitoring (Common for cooling / heating)
Integrators for third party systems on BACnet/MODBUS/LONWORKS/OPC/M-BUS and other industry standard Open protocols for the following Third Party Systems. Integrator should have dedicated one Lon, RS-485 & RS-232 Port with minimum of 96 MB storage.Integrator should be able to store trending to ensure gap free storage.The Third Party Integrator should be from the same manufacturer as that of DDC.
Chillers on BACnet/MODbus/LONworks
Variable Frequency Drives on BACnet/MSTP, MODBUS-RTU Over RS-485
Cabling and Conduiting
Communication & Signal Cabling 2C x 1.5 Sq. mm Shielded Tinned Copper Cable.
MS Conduit 25 mm for Signal & Communication Cable
Hi-wall Split Unit (5 Star Rated) For Various Areas as per basis of design, UPS, Server, Hub Room etc.
Supply, installation, testing and commissioning of Hi-wall Split Unit with rotary compressor & cordless control of following capacity with outdoor unit stand, power & control cabling, MCB etc. as required.
Refrigerant Piping
Supply, installation, testing and commissioning of additional refrigerant piping (two lengths) duly insulated with 25 mm for indoor application and 38 mm for outdoor application closed cell nitrile rubber of density 60+/-10% Kg/m3 to interconnect indoor & outdoor units for each circuit. (Refrigerant piping for individual circuit shall be restricted to maximum length of 25 Meter by AC Contractor)
Hi-wall Split Units (1.5 / 2.0 TR)
Variable Refrigerant Volume / Flow Air-conditioning System
Outdoor Unit
Supply, Instalaltion, testing and commissioning of Modular type outdoor units equipped with highly efficient scroll compressors with all inverter compressor(s), special heat exchanger, ODU dB level less than 50 at a distance 1 Meter, centrifugal fan for condenser, ODU having front suction & top discharge, Y-branch as required, outdoor unit support, auto check function for connection error, auto address setting and capacity as mentioned below. VRF System shall be suitable for working on 48 °C ambient temperature, Refrigerant R 410A. Unit price shall be inclusive of full charge of Refrigerant Gas & Oil, Freight, Insurance, all Taxes & Duties etc. as applicable In INR. The COP of ODU mentioned below shall be at 100% load, 35 °C ambient temperature & at 27 °C DB inside temperature. All interconnecting piping, joints and U bends within the condensing unit shall be painted with two coats of clear transparent polymer coating for protection against corrosion from ambient air pollution.
8 HP Cool / Heat Pump Unit, Single Circuit, Additional Refrigerant As Required For The System)
12 HP Cool / Heat Pump Unit, Single Circuit, Additional Refrigerant As Required For The System)
24 HP Cool / Heat Pump Unit, Single Circuit, Additional Refrigerant As Required For The System)
34 HP Cool / Heat Pump Unit, Single Circuit, Additional Refrigerant As Required For The System)
Double Skinned Floor Mounted VRV DX AHU With Mixing Chamber
Supply, installation, testing and commissioning of factory fabricated customized Double Skinned VRV DX Air-handling unit Floor mounted type fabricated out of extruded aluminium section with 0.8 mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.8 mm plain Galvanised steel sheet inside with blower, blower section and blower motor TEFC type efficiency class IE3 suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 4 / 6 Row cooling coil made of Aluminium finned Copper tube with coil section, Copper Header, pre-filter section with non woven synthetic media MERV 8 filters in extruded aluminium frame, fine filter section with MERV 13 filters in extruded aluminium frame, polished stainless steel drain pan made out of 22 G sheet duly insulated complete with motor, belt drive etc. without face and bypass dampers.
The motor & blower assembly shall be mounted on Aluminium extruded section only. The complete AHU shall conform to specication & face velocity across cooling coil shall be limited to 152 MPM maxm. AHU DX coils shall be in tune with the requirement of VRV Outdoor Unit capacity and 1 / 2 / 3 / 4 equal divisions with respective HP ODU shall be made in cross sectional area of the coil respectively or as per manufacturer standard. The capacity of Air-handlers shall be as follows:
For VRF DX AHU - 2500 CFM, 65 mm St. Pr., 6 Row CC, 355 Dia Fan, 2.2 Kw Fan Motor or as required.
For VRF DX AHU - 7,000 CFM, 65 mm St. Pr., 6 Row CC, 500 Dia Fan, 5.6 Kw Fan Motor or as required.
For VRF DX AHU - 10,000 CFM, 65 mm St. Pr., 6 Row CC, 560 Dia Fan, 7.5 Kw Fan Motor or as required.
Double Skin Floor Mounted VRV DX AHU (For OT With 10 ACH/Hr)
Supply, installation, testing and commissioning of factory fabricated Double Skinned VRV DX Air-handling unit Floor mounted type fabricated out of extruded aluminium section with 0.6 mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.6 mm polished SS sheet inside with blower, blower section and blower motor TEFC type efficiency class IE3 suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 6 Row cooling coil made of Aluminium finned Copper tube with coil section, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% in both the supply & exhaust side of AHU, fine filter section with filters of non woven synthetic media of 5 micron particle size in supply after fan, (Hepa filters shall be at terminals along with laminar flow plenum & not to be included in the cost), mixing chamber, polished stainless steel drain pan made out of 22 G sheet duly insulated complete with motor, belt drive package, guard etc. without face and bypass dampers, Strip heater section with 3 + 3 KW Strip Heater & humidistat.
The AHU panels shall be insulated with 48mm thick & 36 Kg/m³ density PU foam & shall have thermal break. The motor & blower assembly shall be mounted on Aluminium extruded section only. These AHUs shall have air inlet / outlet connection made of aluminium 20 G & all fixing arrangement / blank off shall be of SS. The complete AHU shall conform to specication & face velocity across cooling coil shall be limited to 152 MPM maxm.
AHU DX coils shall be in tune with the requirement of VRV Outdoor Unit capacity and no divisions shall be made in cross sectional area of the coil. If multiple ins and outs of refrigerant pipe are required then coils shall be grouped into required rows keeping the cross sectional area of the coil constant. The capacity of Air-handlers shall be as follows:
VRF/AHU/OT/1 to 4 - 3,000 CFM Supply Air, 6 Row CC, 120 mm St. Pr., Backward Curved Supply Fan, 500 CFM Ex. Air Forward Curved Blower, 40 mm St. Pr. for Exhaust fan with other accessories as specified)
Expansion Kit, Communication PCB & Thermostat
Supply, installation, testing and commissioning of Electronic Type Expansion Kit, Communication PCB with Sensors, Corded Self Diagnostic Type Digital Thermostat, Y-joints etc. as required Including all Taxes & Duties, Freight, Insurance etc. In INR.
For VRF DX AHU Of Capacity 2500 CFM with 8 HP VRV ODU
For VRF DX AHU Of Capacity 7000 CFM with 24 HP VRV ODU
For VRF DX AHU Of Capacity 10000 CFM with 34 HP VRV ODU
For VRF DX AHU Of Capacity 3000 CFM with 12 HP VRV ODU
Humidification Package For OT & ICU
Supply, installation, testing and commissioning of Humidification package with all necessary controls as required as per standard specification & of following capacities:
3.0 KW For OT
1.5 KW For ICU
Laminar Air Flow Plenum For OT
Supply, installation & testing of factory fabricated Laminar air flow pattern perforated plenum made of 16 G aluminium sheet, Aluminium VCD, DOP tested Hepa filters of efficiency 99.97 % down to 0.3 micron particle size & suitable for operation theatre with all accessories as required & to suit site condition of following size :-
Refrigerant Piping for VRV / VRF System
Supply, installation, testing and commissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R 410A duly insulated with elastomeric nitrile rubber type tubular insulation of density 55+/-10% Kg/m3 between indoor & outdoor units as per specifications. External refrigerant piping shall be laid on 16 G GI covered perforated cable trays. Piping inside occupied area & vertical shaft inside the AHU Room shall be supported using 16 G GI hangers. All exposed pipe shall have UV coating on insulation & cost to be included in the piping. Cable tray is quantified seperately.
41.3 mm O.D. (Min. Wall Thickness - 1.43 mm, insulation - 19 mm thick)
34.9 mm O.D. (Min. Wall Thickness - 1.21 mm, insulation - 19 mm thick)
28.6 mm O.D. (Min. Wall Thickness - 0.99 mm, insulation - 19 mm thick)
22.2 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 19 mm thick)
19.1 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 13 mm thick)
15.9 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 13 mm thick)
12.7 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 13 mm thick)
9.5 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 13 mm thick)
6.4 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 13 mm thick)
UPVC Condensate Drain Piping
Supply, installation, testing and commissioning of UPVC condensate drain water piping of density 20 Kg/m³ complete with fittings like elbows, tees, reducers, bends, flanges, supports, insulation etc. as required and of following sizes.
25 mm dia pipe, Insulation Thickness - 13 mm
40 mm dia pipe, Insulation Thickness - 13 mm
50 mm dia pipe, Insulation Thickness - 13 mm
FIRE FIGHTING WORKS
FIRE PUMPS & HYDRANT WORKS
FIRE PUMPS - ELECTRICAL
Supply, installation, testing and commissioning of vertical single stage centrifugal type fire pumps suitable for autometic operation at] synchoronous speed of 2900 rpm, TEFC conforming to IP-55 & flexible coupling gaurd mounted on a common structural base plate with 150mm dia gun metal pressure gauges with isolation cock and piping, suitable vibration elimination pads of approved design for pump foundation, motor to be suitable for 415 volts, 3 phase 50 cycles AC.
Capacity 2850 LPM at 11.0 Kg/cm2 delivery pressure for Fire Hydrant/Sprinkler.
Capacity 180 LPM at 11.0 Kg/cm2 (Jockey Pump).
Capacity 2280 LPM at 8.0 Kg/cm2 delivery pressure for Fire Hydrant/Sprinkler.
Capacity 180 LPM at 8.0 Kg/cm2 (Jockey Pump).
FIRE PUMPS - DIESEL
Supply, installation, testing and commissioning of split casing centrifugal pumping set with CI volute and bronze impeller with mechanical seals directly coupled to automatic Diesel Engine complete with all accessories like self starting by means of Battery powered electric starter motor, Paper Filter type air cleaner, exhaust silencer etc. complete in all respects. The engine & the pump will be mounted on common base plate on anti-vibration mountings.
Capacity 2850 LPM at 11.0 Kg/cm2 delivery pressure for Fire Hydrant & Sprinkler Network.
Capacity 2280 LPM at 8.0 Kg/cm2 delivery pressure for Fire Hydrant & Sprinkler Network.
Oil Tank
Supplying, fixing and commissioning 500 ltrs. capacity including first fill of 500 ltrs high speed diesel oil in 16 SWG MS steel oil tank with manhole cover, glass gauge, inlet and outlet connections with gate valves, drain plug, GI piping between tank and engine vent pipe with wire mesh etc. duly painted and mounted on suitable MS angle staging to maintain gravity flow of oil.
Exhaust piping
Providing & fixing 150 mm diameter M.S. Class 'C' diesel pump exhaust pipe includings all fittings, like bends, tees etc. clamps / structural steel supports. The pipe shall be provided with 75mm thick fiberglass insulation & covering the insulation with 500 g polythene sheet giving proper overlaps & sealing the joints with suitable adhesive compound. The pipe shall be provided with 24 gauge aluminium sheet cladding.
Supply, fabrication (as per code), installation, testing and commissioning of Pressure vessels 450mm diameter and 1000mm high fabricated from 8-10mm M.S. plate with accessories inside painting with epoxy paint and outside with enamel.
Providing, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 20 Kg/cm2 for :-
150 mm dia
80 mm dia
Aluminium podwer coated 1200x2100 door capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. Water CO2 & 1 No. CO2 type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate
Liasioing with civil contractor for making 1200x600x2100 Recessed type mansoary box (by civil contractor).
External/Terrace hydrant/landing valve IS marked of gunmetal with generally as specified and as required all complete.
63mm dia single outlet landing valve IS marked with suitable size bolts, nuts, washers and gaskets. Landing valve shall be TAC Approved Make.
63mm reinforced rubber hoses (RRL) with male and female GM coupling, IS marked- 15 m x 2 lengths
standard short size gunmetal branch pipe with nozzle of 20mm nomnal bor outlet with instaneous type 63 mm dia coupling complete IS marked & TAC approved.
TAC approved M.S. fire hose cabinet (900x350x750\mm) made out of 16 gauge M.S. sheet capable of accommodating landing valve, hose pipes, fittings & accessories. The box shall have a front glass door with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering)
PIPING & VALVES FOR FIRE FIGHTING SYSTEM
Providing and fixing C.I. double acting air valves of approved quality with bolts, nuts, rubber insertions etc.comp;ete ( The tail pieces, tapers etc. if reqd. will be paid separately) 25 mm dia.
SPRINKLERS SYSTEM
Prioviding, fixing, testing & commissioning of istallation control valcve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydrailically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, stariner, pressure switch, cock valve, complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plante, gaskets etc of following sizes complete as required
Supply, installation, testing and commissioning of 150 mm dia Zonal Control Valve inclusive of 1 nos 150 mm dia butterfly valve, 150mm diam. non return valve, Flow Switch, water pressure gauges & 25 mm dia. Auxillary Drain valve with sight glass with necessary GI (H) piping with threaded fittings of required sizes complete
FIRE EXTINGUISHERS
Providing, storing, handling, shifting, installation, testing and commissioning of portable fire Extinguishers as described below:
ISI marked (IS:15683) 4.5 kg carbon dioxide extinguisher, IS marked, with high pressure discharge tube, horn, control valve, CCE approved cylinder
ISI marked (IS:15683) 6 kg Mono Ammonium Phosphate (ABC) type cartridge operated extinguishers
ISI marked (IS:15683) 22.5 Kg. CO2 Fire Extinguisher
ELECTRICAL WORKS
CUBICAL FIRE PANEL BOARD
Supply, installation, testing and commissioning of following fire fighting panel suitable for 415V, 3 phase, 4 wires, 50 HZ power distribution system. The panel shall be free standing floor mounting sheet metal sheet inclosed dust and vermin prooof conforming to IP-52, Compartmentalized design, fabricated out of 14SWG sheet steel, painting, earthing numbering, danger plate as per specifications and drawings, flush front with Aluminium busbars, separate earth to be provieded throughout the length of the panel. The incoming and outgoing feeder breakers, fuses, indicating lamps etc shall bne accommodated in modular multitier arrangement. The painting shall done as relevant IS codes/as specified in the specifications. Adequate size cable alley shall be provided al round the panel and in the back for each cable bending and termination. The panel shall be fabricated by TAC/Fire authority approved vendor. The outgoing feeders inside the panel shall be connected through solid bus bars.
Bus bars shall be provided with heat shrinkable sleeves and shall be colour coded . The panels shall be suitable for cable entry from top. The minimum fault rupturing of all incoming and outgoing switches/breakers shall be 35KA. The panels shall be fabricated after the approval of fabrication drawings.
i) For 2 x 120 HP Wet Riser & Sprinkler Pump
ii)For 2 x 15.0 HP Jockey Pumps
Supply, installation, testing and commissioning of non draw out Cubical type sectinalised floor standing powder coated switch board of 31 MVA fault capacity at 415 V complete with 4 strip, 800 A capacity Aluminium Bus - Bar Electrolytic grade, cable alley & supplying & fixing of following switchgears as per specifications including connections & interconnections.
INCOMER
One (1) No. 400 A TPN MCCB (35KA).
500 Amps Aluminium bus bar shall be insulated with heat shrinkable sleeves and shall be coded.
Three (3) Nos. current transformer (400/5A).
1 Set (3 Nos.) of phase indication lamps with HRC fuses.
Indication for control supply 'healthy'.
OUTGOINGS
one (1) Nos.250A TPN MCCB 35KA.
One (1) 63A TPN MCB 10KA
One (2) Nos. Star Delta Starters complete with over load realy with single phasing protection feature. On / Off & TRIP, indication lamp, contactors, ammeter with suitable C.T's suffcient nos. of potential free spare contacts, etc. Suitable for 120 HP Motor.
Pressure Switch.
Wiring from pressure switch to starter - Lot
One (2) Nos. Star Delta Starters complete with over load realy with single phasing protection feature. On / Off & TRIP, indication lamp, contactors, ammeter with suitable C.T's suffcient nos. of potential free spare contacts, etc. Suitable for 15 HP Motor.
One (1) No. pressure Switch.
Wiring from pressute switch to starter -Lot
Set of control system to make the system automatic as per functionl as requirements.
Provision for starting the diesel engine fire pump with battery charger for trickle & boost charging. The diesel engine driven fire pump shall start automatically in the event of pressure dorop beyong preset limit on mains faulure or failure of electrical driven pumps to start.
Pressure Switch.
Wiring from pressure switch to Diesel engine control panel.
One (1) No. 100A TPN MCCB (35KA).
Note:- CABEL CONNECTION
Control Scheme as per specification
Following provisions to be made in the fire panel:
Audio visual alarm & indications having disconnect/reset facility with a range of 1/2 km. Annunciator to be provided in the Fire panel with hooter and acknowledge, test and reset P Bs. The indication shall come on when electrical driven pump set fails to start on pressure drop or when there is power failure during pressure drop.
Protection failure & control cabling.
Panel shall be interlocked in such a way when fire pump starts on pressure drop in the header, supply to working chiller A/c panel is disconnected.
Remote indication of ON/OFF/TRIP shall be provided through potential free contact.
Provuision of remote starting/stopping (manuals) of the engine shall be made.
All pumps operation shall be controled by flow switches.
The logic of control panel based on specification attached.
All pumps shall be working automatically or manually.
Electric Panel as Describe Above.
POWER & CONTROL CABLING
Supply, laying, testing and commissioning of power and control cabling, as per Standard specification including end termination, cable tray, earthing etc as required.
Power Cabling (XLPE) insulated and PVC sheathed, armoured, Aluminium Conductor of 1.1 KV grade on existing cable trays).
3C x 150 Sq. mm
3C x 50 Sq. mm
3C x 6 Sq. mm
Control Cabling ( PVC insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on existing cable trays).
5C x 1.5 Sq. mm
2CX 1.5 Sq. mm
Earthing Strip / Wires.
AUTOMATIC FIRE DETECTION SUPPRESSION SYSTEM
5 LB capacity Novec 1230 , DLP Assembly with automatic valve, push in connector for tube, 5 LB Novec 1230 gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.
10 LB capacity Novec 1230 , DLP Assembly with automatic valve, push in connector for tube, 10 LB Novec 1230 gas , mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.
Linear Pneumatic Heat detection tube with all necessary & supperts
Master Control Unit with Audio Visual Alarm with wiring to make complete system operational . The control Panel should have provision for integration with fire Alarm /SCAD/BMS System.
IT WORK
Supply, Installation, Testing & Commissioning of Cat-6A Mounting Cords 7 Feet for Data,Standardization: Compliant with Cat.6A, Class EA requirements: ISO/IEC 11801 2.1 Edition Compliant with Cat.6A component,Cat 6A patch cord plug to have round cable holder and strain relief boot to avoid bending,Should be ETL certified as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of Cat-6A Mounting Cords 4 Feet ,Standardization: Compliant with Cat.6A, Class EA requirements: ISO/IEC 11801 2.1 Edition Compliant with Cat.6A component,Cat 6A patch cord plug to have round cable holder and strain relief boot to avoid bending,Should be ETL certified for Data Jack Panel end as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of Cat-6A, 24 Port Jack Panel UTP/STP keystone-type jacks in 1U,Standard : Conforms to IEC-60603-7 (603-7) for keystone-type, Snap-On apertures,,Patch panel should be Enhanced with cable strain relief with retention tray; It should be single metal both front panel and rear tray,Should be RoHS complied for data as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of Cat-6A Mounting Cords 4 Feet,Standardization: Compliant with Cat.6A, Class EA requirements: ISO/IEC 11801 2.1 Edition Compliant with Cat.6A component,Cat 6A patch cord plug to have round cable holder and strain relief boot to avoid bending,Should be ETL certified for Voice Jack Panel end as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of Cat-6A 24 Port Jack Panel UTP/STP keystone-type jacks in 1U,Standard : Conforms to IEC-60603-7 (603-7) for keystone-type, Snap-On apertures,,Patch panel should be Enhanced with cable strain relief with retention tray; It should be single metal both front panel and rear tray,Should be RoHS complied for Voice Field as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of Cat-6A 24 Port Jack Panel UTP/STP keystone-type jacks in 1U,Standard : Conforms to IEC-60603-7 (603-7) for keystone-type, Snap-On apertures,,Patch panel should be Enhanced with cable strain relief with retention tray; It should be single metal both front panel and rear tray,Should be RoHS complied for Voice Field as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of 15 U Wall Mount Rack as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of 1 U PVC Cable Manager as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of 6 socket PDU as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of Mounting Hardware pack of 10pcs as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of 10 Pair Krone Module as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of 200 Pair MDF Box with Mounting Frame as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of 25 Pair Riser cable as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of 6 Core Multi Mode (OM4) Fiber ( Armored with Central Strength steel member), Thickness: 1.6mm,Fibre Count: 6, Loose tube count :1, Fibre count per tube :6, Filler count :4,Filler Material: PP,Fibre Optic Cable: ISO/IEC-1180, 9/125μ, OS2 Outdoor, AS PER ITU/T 652D. BELLCORE GR 20 / IEC 794-1, Qualifies as per ICEA-640,Gel-Filled Outdoor Cable is tested in accordance with Telcordia GR-20. RoHS Compliance,Max. Tensile Strength-Short Term: 1500N Max. Crush Resistance-Short Term: 2200N/100 mm as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of 12 Port Fiber LIU Loaded with12F, 1U, SC/LC MM, with Pigtail, loaded with Splice tray & Couplers & Splice Protectors (Fibre Optic LC/SC style Fully Loaded Patch Panel (FOPP), Pigtails shall comply: G.652.D, G.657.A1 and OS2,19" Rack Mount with min 12 nos. of OS2 9/125μ Pigtails and this LIU should have provision for 48 fiber in 1U.),1 Nos. of Earthing lugs (inbuilt or additionally), pre-loaded Front and rear cable management rings, as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of 24 Port Fiber LIU Loaded with 12F, 1U, SC/LC MM, with Pigtail, loaded with Splice tray & Couplers & Splice Protectors (Fibre Optic LC/SC style Fully Loaded Patch Panel (FOPP), Pigtails shall comply: G.652.D, G.657.A1 and OS2,19" Rack Mount with min 12 nos. of OS2 9/125μ Pigtails and this LIU should have provision for 48 fiber in 1U.),1 Nos. of Earthing lugs (inbuilt or additionally), pre-loaded Front and rear cable management rings, as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of SC MM Pigtail (1.0 Mtr) as per given Specification etc. all complete.( All passive from one OEM ( RIT/Commscope/ Siemon/Panduit)
Supply, Installation, Testing & Commissioning of Blank Panel for LIU,12 Fiber / 16 Fiber 3 nos Adopter plate provision as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of SC-LC MM Fiber Patch Cords ( 3 Mtr) as per given Specification etc. all complete.All passive from one OEM ( RIT/Commscope/ Siemon/Panduit)
Supply, Installation, Testing & Commissioning of UK style Keystone-type Faceplates are available in 1, 2 & 4 port configurations,Should support Work with both Flush and Wall mount box,Material: ABS, UL 94V-0; Spring: SUS304; Surface Finish: Polished,Should be featured with shutter options, the screws not to be visible faceplate with Gang Box etc all complete.
Supply, Installation, Testing & Commissioning of LSZH Cat 6A-10G speed unshielded twisted pair computer cable with 23 AWG solid copper conductors in existing concealed/surface conduits/Raceways complete 305 Mtr.cableRoll, cable shall be compliant with ANSI/TIA/EIA-568-C.2; ISO/IEC 11801 Ed. 2.0; 10BASE-T, IEEE 802.3 af (PoE), 100BASE-T, IEEE 802.3at (PoE+) & 1000BASE-T,ETL 4 port channel Test report should be submitted with 800 Mhz,Should be ETL Certified as per specification etc. all complete.
Supply, Installation, Testing & Commissioning of UTP Cat-6A Information Outlet Red for Data as per specification etc. all complete.
Supply, Installation, Testing & Commissioning of UTP Cat-6A Information Outlet Yellow for Voice as per specification etc. all complete.
Supply, Installation, Testing & Commissioning of Layer 3 Distribution Switch minimum 24 no. of 10 Gig SFP+ ports and 4 nos. of 10 GBPS uplink ports from Day-1.Switch should have hot swappable 1:1 redundant internal power supply.as per the given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of Layer 2 Switch 24 10/100/1000 Base-T ports and additional 4 nos. 10gbps SFP+ uplinks portsport as per the given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of Access point which can support the given Controller and Wireless A P Indoor Access Points proposed must include radios for 2.4 GHz and 5 GHz with 802.11ac Wave 2 with mounting accessories as per the given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of Analog Phone With Speaker , Small Display etc. all complete.
Supply, Installation, Testing & Commissioning of 300 Pair MDF Box with Mounting Frame as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of 1800 Pair MDF Box with Mounting Frame as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of DK PS Frame,1000Wx2000Hx1200D (2nos. of 1000Wx2000Hx600D with Baying tube), Top cover with rear fixed & slideable gland plate with foam insert for cable entry, bottom cover with standard gland plates with foam insert for cable entry and rear 4nos. of 50mm dia rubber grommets as per std., 2 pairs of 42U 19" L - type angles & special assembly kit for mounting 19" angles & punched sections, Complete with 11 KVA Power and 7KW Cooling in complete. It consist of in built Temperature, Humidity, Automatic door opening & leakage Monitoring System. with Signal Pillar Fire Extinguisher System as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of 6 Core Single Mode Fiber ( Armored) Cable,Should fulfill the requirements of ISO.IEC 11801 - 2nd Edition, type OS2, ITU-T REC G 652D spec IEC 60794-1-2 F5,Fibre/Tube Identification : Multi Tube,Thickness : 1.6mm,Central Strength Member: Steel wire coated with PE,Mass (Nominal) : 91 kg/km,Max. Tensile Strength-Short Term : 1500N, Max. Crush Resistance-Short Term : 2200N/100 mm,Fibre protection (Tubes) : Polybutylene Terephthalate (PBT) as per given Specification etc. all complete.All passive from one OEM ( RIT/Commscope/ Siemon/Panduit)
Supply, Installation, Testing & Commissioning of 12 Port Fiber LIU Loaded with Coupler,Fiber optic patch panel FMS Termination Drawer should have sufficient slots to accommodate 3 of 12/16 Port LC Adaptor Plates,Splice Tray of ABS, Comply with UL 94V2 material should be supplied with LIU.6 Duplex LC Adapters, SM, UPC with F/O Pigtail, LC, SM, G657A2, PC, LSZH, 1m,Height: 1 U, 1.75 inches (12 and 48 Ports),All LC adapters should be duplex type with shutter for protection. Adapters should be snap mount for easy insertion and removal,empty Slots of FMS should be covered with blank plates,Insertion Loss: <0.2 to <0.1 dB, RoHS Compliant as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of 24 Port Fiber LIU Loaded with Coupler,Fiber optic patch panel FMS Termination Drawer should have sufficient slots to accommodate 3 of 12/16 Port LC Adaptor Plates,Splice Tray of ABS, Comply with UL 94V2 material should be supplied with LIU.6 Duplex LC Adapters, SM, UPC with F/O Pigtail, LC, SM, G657A2, PC, LSZH, 1m,Height: 1 U, 1.75 inches (12 and 48 Ports),All LC adapters should be duplex type with shutter for protection. Adapters should be snap mount for easy insertion and removal,empty Slots of FMS should be covered with blank plates,Insertion Loss: <0.2 to <0.1 dB, RoHS Compliant as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of SC SM Pigtail (1.0 Mtr) as per given Specification etc. all complete. All passive from one OEM ( RIT/Commscope/ Siemon/Panduit)
Supply, Installation, Testing & Commissioning of Fiber Patch Cords ( 3 Mtr),LC-LC 9/125μm OS2 Single mode Duplex Patch Cord Length : 3Mtrs,The optical fiber patch leads shall comprise of Single mode 9/125μm fiber with 2XLC type fiber connectors terminated at each end of fiber patch cord.et Material : LSZH complying to IEC 61034-1 & 2,IEC?60332-1, IEC-60754-1 & 2,Connector Loss: 0.30dB(max) ,Operating Temperature: -40°C to +75°C as per given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of Fiber Runner 4x4 QuikLock Coupler etc. all complete.
Supply, Installation, Testing & Commissioning of Fiber Runner 4x4 Channel etc. all complete.
Supply, Installation, Testing & Commissioning of Fiber Runner 2x2 Hinged Cover etc. all complete.
Supply, Installation, Testing & Commissioning of Fiber Runner 4x4 Snap-On Hinged Cover etc. all complete.
Supply, Installation, Testing & Commissioning of Fiber Runner 4x4 QuikLock Trapeze Bracket - 1/2'' Threaded Rod etc. all complete.
Supply, Installation, Testing & Commissioning of Fiber Runner Spill-Over Junction with 2x2 Exit (yellow) etc. all complete.
Supply, Installation, Testing & Commissioning of Fiber Runner Spill-Over Junction with 2x2 Exit - Fiber Runner 4x4 Channel Cover (yellow) etc. all complete.
Supply, Installation, Testing & Commissioning of Fiber Runner 2x2 QuikLock Coupler etc. all complete.
Supply, Installation, Testing & Commissioning of Corrugated Loom Tubing - 1.5'' I.D. etc. all complete.
Supply, Installation, Testing & Commissioning of Fiber Runner 2x2 Hinged Channel - Mounting Holes etc. all complete.
Supply, Installation, Testing & Commissioning of Fiber Runner 4x4 End Cap etc. all complete.
Supply, Installation, Testing & Commissioning of Fiber Runner 4x4 Horizontal Tee Fitting etc. all complete.
Supply, Installation, Testing & Commissioning of Fiber Runner 4x4 Horizontal Tee Split Cover etc. all complete.
Supply, Installation, Testing & Commissioning of Fitting, 1-Port Spill out to 1.5'' (38mm) Inside Diameter Corrugated Tubing, YL etc. all complete.
Supply, Installation, Testing & Commissioning of QuikLock Hardware Nut Driver etc. all complete.
Supply, Installation, Testing & Commissioning of Full-length blanking shade blanks etc. all complete.
Supply, Installation, Testing & Commissioning of LSZH Cat 6A-10G speed unshielded twisted pair computer cable with 23 AWG solid copper conductors in existing concealed/surface conduits/Raceways complete 305 Mtr.cableRoll, cable shall be compliant with ANSI/TIA/EIA-568-C.2; ISO/IEC 11801 Ed. 2.0; 10BASE-T, IEEE 802.3 af (PoE), 100BASE-T, IEEE 802.3at (PoE+) & 1000BASE-T,ETL 4 port channel Test report should be submitted with 800 Mhz,Should be ETL Certified as per specification etc. all complete.All passive from one OEM ( RIT/Commscope/ Siemon/Panduit)
Supply, Installation, Testing & Commissioning of Layer 3 Distribution Switch minimum 24 no. of 10 Gig SFP+ ports and 4 nos. of 10 GBPS uplink ports from Day-1.Switch should have hot swappable 1:1 redundant internal power supply.as per the given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of Wireless LAN Controller (On Prim/Cloud based) whichcan control up to 250 APs as per the given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of Layer 2 Switch 48 10/100/1000 Base-T ports and additional 4 nos. 10gbps SFP+ uplinks portsport as per the given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of Access point which can support the given Controller and Wireless A P Indoor Access Points proposed must include radios for 2.4 GHz and 5 GHz with 802.11ac Wave 2 with mounting accessories as per the given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of Mail & Database Server which can support the data and Mail system as per the given Specification etc. all complete.
Supply, Installation, Testing & Commissioning of 100% Non Blocking Fully Digital Integrated Services Digital Network (ISDN) Compatible Voice Over Internet Telephone(VoIP) ready 19" Rack mountable EPABX presently equiped with 06 ISDN PRI Trunk Lines (180 Channel), 32 IP Extension, 64 Digital Extension, 800 Analogue Extension, Expandable up to 2000 Ports / Channels and other as per the given Specification etc. all complete. NEC SV9100 PBX configured with - 06 ISDN PRI Trunk - 64 Digital Extensions - 800 Analouge Extensions - 32 IP Extensions
Supply, Installation, Testing & Commissioning of IP User Linceses for 10 Users etc. all complete.
Supply, Installation, Testing & Commissioning of 16 Port Digital Card etc. all complete.
Supply, Installation, Testing & Commissioning of 24 Port Analouge Card etc. all complete.
Supply, Installation, Testing & Commissioning of High End Digital Key Phone 6x24 Display with 24 Programmable Dual Color LED’s with 4 Feature Access Keys, multi-step Tilt angle adjustment, Navigator Key, backlit display, should have option to connect Blue Tooth etc. all complete.
Supply, Installation, Testing & Commissioning of Low end DIgital Key Phone 1x16 Display with 8 Programmable Dual Color LED’s etc. all complete.
Supply, Installation, Testing & Commissioning of IP PHONE with color Touch LCD screen, built-in graphical user interface (GUI). Includes built-in speakerphone, SD card slot for programming and data backup, Bluetooth compatible (with optional module), able to register IP Cameras and control PTZ functionality ,Blue Tooth , Power over Ethernet (PoE) etc. all complete.
Supply, Installation, Testing & Commissioning of IP Phone 1x16 Display with 8 Programmable Dual Color LED’s etc. all complete.
PUC SYSTEM
Supply, Installation, Testing and Commissioning of DLP Solid state(Laser Phosphor) Projection system with ultra short throw lens maximum throw ratio 0.25 UST having 5000 Lumens, 3D available, 1920 x 1200 Resolution,1800:1 Contrast Ratio, illumination Life 20000 hours, Inputs: HDMI, HDBaseT should be complete with standard accessories as required.
Supply, Installation, Testing & Commissioning of Ceiling Mount kit for projector with all required accessories etc. all complete.
Supply, Installation,Testing & Commissioning of 80" diagonal motorized projection screen with an aspect ratio of 16:10. Screen fabric should in accordance with DIN 4102-1 Class B2 materials. Screen should Sustain temperature of 23 ± 2 °C, and a relative humidity of 50 ± 6 %. Should equipped with RS 232/485 Relay Connectivity. Screen Should have Anti Heat Cut off Option to avoid any Calamity at site. Heavy Dowel to maintain Flatness. Screen Fabric should meet the requirements of Class B2 of building materials. Should be supplied with complete standard accessories as required.
Supply, Installation, Testing & Commissioning of Wireless Presenter: Wireless operating distance: Approx 10m, Wireless technology: 2.4GHzwireless technology, Interface: USB etc. all complete.
Supply, Installation, Testing & Commissioning of Table top Document Camera CMOS Sensor, 20x optical zoom and 12x digital zoom, 30 fps, 400 x 300 mm capturing area, HDMI Out, HDMI In, In-built 100 Frames Memory which should be expandable to 2TB through external storage, Standalone Audio Video Recording on USB Drive, In-built Mic, Top Light x 2, In-built Backlight for X-rays, Negatives, Slides etc. OEM should be BIS, CE,RoHS & FCC Certified
Supply, Installation, Testing & Commissioning of HDMI extender set that should have a 2x1 auto switching HDBaseT 2.0 transmitter receiver set that supports the long distance transport of HDMI, VGA and High Speed USB 2.0 signals up to 100 meters / 330’ using category cabling. The set should be 4K compatible with a max resolution of 4K@60Hz / 4:2:0 8bit deep color.The receiver should features integrated 4 port USB 2.0 high speed device hub. An additional analog audio pass through input should be located on the wall plate that allows for audio distribution to the HDBaseT receiver side. With 48V integrated PoH, the set can be powered via HDBaseT receiver with a PSE module or the wall plate can be powered by a local power supply. The set should give you the ability to automate the display power ON by using pre-loaded RS232 commands whenever a video signal is introduced to the system using either the HDMI or VGA input. It should also turn the display power OFF after a specified amount of time has passed when no video signal is present.
Supply, Installation, Testing & Commissioning of 4x2 HDMI 2.0 Auto-switcher, 4K60 4:4:4 / HDR 18G Matrix switcher with audio de-embed, ARC, IR, & RS232 control, Auto-switch or manual switch between four HDMI inputs, 1x HDMI and 1x 3.5mm TRS audio (ARC & audio de-embedding) output Front panel, Supports resolutions up to 4k@60Hz, 4:4:4. 8 bit deep color, Supports HDR formats, HDCP 2.2 compliant, Supports EDID management, Supports CEC pass through control of source / display
Supply, Installation, Testing & Commissioning of HDMI 2.0 HDBaseT Extension Set, Extend HDMI 2.0 signals up to 4K@60Hz / 4:4:4 up to 70m (4K 40m / 1080P 100m), Complete set Includes TX, RX, power supply, and IR flasher/emitter, Extends bi-directional IR. Flexible PoC (Power on either end), Supports HDR10, HDCP 2.2 compliant, Flexible power design (use power supply at TX or RX)
Supply, Installation, Testing and Commissioning Wireless Handheld Microphone System, Wireless Microphone system with MHZ carrier frequency band, Up to 16 pre-programmed frequencies within the same frequency band, Audio bandwidth 35 - 20,000 Hz THD at 1 kHz: <0.3% (Receiver) , Signal-to-noise: 120 dB(A) ( Receiver), Wideband FM Modulation, Up to 48 Simultaneous channels , up to 14 hours operation with one single AA battery or better, Pilot Tone, transmission to know the transmitter battery status, Receiver should have microphone level and line level output, Transmitter should have display to show the battery and LED to show the Muted /Unmuted status Sensitivity 6.3 dB V / -100 dBm, Should have Microprocessor-controlled diversity, T.H.D.: 0.7 % (Transmitter), Infrared programmable, RF output power: 10 or 50 mW With Twin Channel True Diversity Wireless Receiver. offers users upto 16 simultaneous operating channels, over a PLL synthesized circuit and anti-interference support, True-Diversity dual channel receiver comes in a 19" rack size and can be mounted using the rack mount accessory. The RF range for the receiver is 100m (Line of Sight)
Supply, Installation, Testing and Commissioning Wireless Lavaliere Microphone System, Wireless Microphone system with MHZ carrier frequency band, Up to 16 pre-programmed frequencies within the same frequency band, Audio bandwidth 35 - 20,000 Hz THD at 1 kHz: <0.3% (Receiver), Signal-to-noise: 120 dB(A) ( Receiver), Wideband FM Modulation Up to 48 Simultaneous channels, up to 14 hours operation with one single AA battery or better, Pilot Tone transmission to know the transmitter battery status, Receiver should have microphone level and line level output, Transmitter should have display to show the battery and LED to show the Muted /Unmuted status, Sensitivity 6.3 dB V / -100 dBm, Should have Microprocessor-controlled diversity, T.H.D. 0.7 % (Transmitter), Infrared programmable, RF output power: 10 or 50 mW
Supply, Installation, testing and commissioning of high impedence Class D Dual zone amplifier with output power of upto 2x120W @ 70/100V. frequency response of 55 Hz - 20 kHz (+0/–3 dB, @ 1 W reference 1 kHz); THD <0.3% at rated power. Channel Separation ≤ –60 dBV (below rated power, 1 kHz), Dynamic range > 88 dB. Shall include priority override and Fire alarm interface, shall include necessary loudspeaker EQs.
Supply, Installation, testing and commissioning of Premium 12-Input 2-Bus Mixer with XENYX Mic Preamps and Compressors, British EQ and USB/Audio Interface, Built-in stereo USB/Audio Interface to connect directly to computer. 1 post fader FX send per channel for external FX devices, Main mix outputs plus separate control room, phones and 2-Track outputs, 2-Track inputs assignable to main mix or control room/phones outputs.
Supply, Installation, Testing and Commissioning of Control System. Controller with Minimum 4 bidirectional RS232, 4 IR, 4 Relays and 4 GP/IO and 1 Ethernet port to control all the devices in the room. Should have inbuilt or external IR sensor/learner to learn IR commands. The compatible relay controller to control the Projector screen up down should be supplied as a package (may be from same OEM of controller or different). Should have inbuilt processing power and internal storage to store and process the control program. Should be compatible with any (IOS/Android) wireless or wired Touch screen of any size. Additional ports if required can be added with minimum hassle. Should have the flexibility to add as many user interfaces as required. Should have embedded webpage for control port settings. Should have Status LED to check for Control/Connection status. It should support PoE. It should have minimum 5 license each included for both iOS & Android application. Certification: CE, ISO 9001, ISO 14001, OHSAS 18001. Extra component or equipment maybe added to match the complete specs.
Supply, Installation, testing and commissioning of Wireless 10" touch Panel. Should support Wi-Fi (802.11a/b/g/n/ac); dual band (2.4GHz and 5GHz); HT80 with MIMO, Bluetooth 4.2 technology, 500 nits brightness.
Supply, Installation, Testing & Commissioning of 18 AWG (24/0.20mm) x 2 core ATC copper conductor, PE insulated, core twisted in a circular form, Inner sheathed with moisture Proof Polymer, braid shielded (80%) with ATC copper, outer Jacketed with Matt finish Rugged Flexible PVC.
Supply, Installation, Testing & Commissioning of Speaker Cable – 1.5 Sq. mm (48/0.20mm) x 2 core cable ATC copper conductor PVC insulated, core twisted, outer jacketed with Vasiform Type PVC Sheath.
Supply, Installation, Testing & Commissioning of High−performance 15 ft cable that supports signals up to 4K@60Hz (4:4:4), Deep color Should have Gold Plated pins with 28 AWG.Flammability Rating should be CL3/FT4,: RoHS 2011/65/ EU
Supply, Installation, Testing & Commissioning of High−performance 6 ft cable that supports signals up to 4K@60Hz (4:4:4), Deep color Should have Gold Plated pins with 28 AWG.Flammability Rating should be CL3/FT4,: RoHS 2011/65/ EU
Supply, installation , testing and Commissioning of VGA with Audio cable (15 feet). High−performance cable with male 15−pin HD and 3.5mm stereo audio connectors at each end. Should have Gold Plated pins. Should have conductor 26 AWG 7/34 tinned copper All pins should be connected for DDC2 and EDID support. Should be maximum 0.35 inch in diameter. Outer Jacket should be HD polyethylene, Dielectric: Foam polyethylene. Compliance: UL: CL2, CSA: C(UL) CL2
Supply, Installation, Testing & Commissioning of Rack Structure 12 U Air Cooled AV Equipment Rack with Two Nos. of Vertical Power Strips, Cantilever Selves, Cable routing perforations, 4 No. of Spin Wheels etc. all complete.
Supply, Installation, Testing and Commissioning of 55" LCD panel with 3840 X 2160 resolution or better, USB playback,bluetooth and meracast connectivity,4X HDMI 2.0,DP1.2, HDR10,500 nits or better, Video wall mode should be available, contrast ratio : 1200:1, OPS slot,should have 178 degrees viewing angle complete with mounting and accessories.
Supply, Installation, Testing and Commissioning Wireless Handheld Microphone System, Wireless Microphone system with MHZ carrier frequency band, Up to 16 pre-programmed frequencies within the same frequency band, Audio bandwidth 35 - 20,000 Hz THD at 1 kHz: <0.3% (Receiver) , Signal-to-noise: 120 dB(A) ( Receiver), Wideband FM Modulation, Up to 48 Simultaneous channels , up to 14 hours operation with one single AA battery or better, Pilot Tone, transmission to know the transmitter battery status, Receiver should have microphone level and line level output, Transmitter should have display to show the battery and LED to show the Muted /Unmuted status Sensitivity 6.3 dB V / -100 dBm, Should have Microprocessor-controlled diversity, T.H.D.: 0.7 % (Transmitter), Infrared programmable, RF output power: 10 or 50 mW With Twin Channel True Diversity Wireless Receiver. offers users upto 16 simultaneous operating channels, over a PLL synthesized circuit and anti-interference support, True-Diversity dual channel receiver comes in a 19" rack size and can be mounted using the rack mount accessory. The RF range for the receiver is 100m (Line of Sight)
Supply, Installation, testing and commissioning of high impedence Class D Dual zone amplifier with output power of upto 2x120W @ 70/100V. frequency response of 55 Hz - 20 kHz (+0/–3 dB, @ 1 W reference 1 kHz); THD <0.3% at rated power. Channel Separation ≤ –60 dBV (below rated power, 1 kHz), Dynamic range > 88 dB. Shall include priority override and Fire alarm interface, shall include necessary loudspeaker EQs.
Supply, Installation, testing and commissioning of Premium 12-Input 2-Bus Mixer with XENYX Mic Preamps and Compressors, British EQ and USB/Audio Interface, Built-in stereo USB/Audio Interface to connect directly to computer. 1 post fader FX send per channel for external FX devices, Main mix outputs plus separate control room, phones and 2-Track outputs, 2-Track inputs assignable to main mix or control room/phones outputs.
Supply, Installation, Testing and Commissioning of 18 AWG (24/0.20mm) x 2 core ATC copper conductor, PE insulated, core twisted in a circular form, Inner sheathed with moisture Proof Polymer, braid shielded (80%) with ATC copper, outer Jacketed with Matt finish Rugged Flexible PVC.
Supply, Installation, Testing and Commissioning of Speaker Cable – 1.5 Sq. mm (48/0.20mm) x 2 core cable ATC copper conductor PVC insulated, core twisted, outer jacketed with Vasiform Type PVC Sheath.
Supply, Installation, Testing & Commissioning of Rack Structure 20 U Air Cooled AV Equipment Rack with Two Nos. of Vertical Power Strips, Cantilever Selves, Cable routing perforations, 4 No. of Spin Wheels etc. all complete.
Supply, Installation, Testing and Commissioning of DLP Solid state(Laser Phosphor) Projection system with ultra short throw lens maximum throw ratio 0.25 UST having 5000 Lumens, 3D available, 1920 x 1200 Resolution,1800:1 Contrast Ratio, illumination Life 20000 hours, Inputs: HDMI, HDBaseT should be complete with standard accessories as required.
Supply, Installation, Testing and Commissioning of 1-chip DLP LASER Phosphor Multimedia Projection system having, 7000 Lumens 20000 hours lamp life, 1920 x 1200 WUXGA Native Resolution, Inbuilt blending and warping with automatic caliberation software, 3D ready, 1200000:1 Contrast Ratio, inputs: HDBaseT,HDMI2.0, DVI-D, Active 3D, Motorised zoom and focus, alongwith 1.25-2.0 lens. Should be complete with standard accessories as required.
Supply, Installation, Testing & Commissioning of Retractable Motorised Micro Ceiling Lift Voltage: 220V 50Hx or 110V 60Hx, , Dimension: 500×450×200mm (L×W×H), Loading Capacity: 25KG, Travel Length:100 cm with all require accessories etc. all complete.
Supply, Installation,Testing & Commissioning of 80" diagonal motorized projection screen with an aspect ratio of 16:10. Screen fabric should in accordance with DIN 4102-1 Class B2 materials. Screen should Sustain temperature of 23 ± 2 °C, and a relative humidity of 50 ± 6 %. Should equipped with RS 232/485 Relay Connectivity. Screen Should have Anti Heat Cut off Option to avoid any Calamity at site. Heavy Dowel to maintain Flatness. Screen Fabric should meet the requirements of Class B2 of building materials. Should be supplied with complete standard accessories as required.
Supply, Installation, Testing & Commissioning of 120" diagonal motorized projection screen with an aspect ratio of 16:10. Screen fabric should in accordance with DIN 4102-1 Class B2 materials. Screen should Sustain temperature of 23 ± 2 °C, and a relative humidity of 50 ± 6 %. Should equipped with RS 232/485 Relay Connectivity. Screen Should have Anti Heat Cut off Option to avoid any Calamity at site. Heavy Dowel to maintain Flatness. Screen Fabric should meet the requirements of Class B2 of building materials. Should be supplied with complete standard accessories as required.
Supply, Installation, Testing & Commissioning of 150" diagonal motorized projection screen with an aspect ratio of 16:10. Screen fabric should in accordance with DIN 4102-1 Class B2 materials. Screen should Sustain temperature of 23 ± 2 °C, and a relative humidity of 50 ± 6 %. Should equipped with RS 232/485 Relay Connectivity. Screen Should have Anti Heat Cut off Option to avoid any Calamity at site. Heavy Dowel to maintain Flatness. Screen Fabric should meet the requirements of Class B2 of building materials. Should be supplied with complete standard accessories as required.
Supply, Installation, Testing and Commissioning of 55" LCD panel with 3840 X 2160 resolution or better, USB playback,bluetooth and meracast connectivity,4X HDMI 2.0,DP1.2, HDR10,500 nits or better, Video wall mode should be available, contrast ratio : 1200:1, OPS slot,should have 178 degrees viewing angle complete with mounting and accessories.
Supply, Installation, Testing and Commissioning of 75" LCD panel with 3840 X 2160 resolution or better, USB playback,bluetooth and meracast connectivity,4X HDMI 2.0,DP1.2, HDR10,400 nits or better, Video wall mode should be available, contrast ratio : 1200:1, OPS slot,should have 178 degrees viewing angle complete with mounting and accessories.
Supply, Installation, Testing and Commissioning of Wireless Presentation Solution, enables wireless presentation of 4K Wireless Display, App-free, Wireless Touch, Extended Screen support, shall offer Enterprise Management features, up to four Shared screens simultaneously, and annotate in Office 365 apps and share notes to devices or the front-of-room display, supports display resolutions up to 4K and FUII HD 1080P and UXGA/WUXGA, Provides HDMI / VGA / mini-DisplayPort, and analog audio outputs etc. all compete.
Supply, Installation,Testing & Commissioning of Flush mount Cable Manager with multi-format cables and a comfortable flip-open cover. Shall have 1x universal Power socket, 1x HDMI Cable, 1x USB Charger and etc. complete with standard accessories as required.
Supply, Installation, Testing & Commissioning of Table top Document Camera CMOS Sensor, 20x optical zoom and 12x digital zoom, 30 fps, 400 x 300 mm capturing area, HDMI Out, HDMI In, In-built 100 Frames Memory which should be expandable to 2TB through external storage, Standalone Audio Video Recording on USB Drive, In-built Mic, Top Light x 2, In-built Backlight for X-rays, Negatives, Slides etc. OEM should be BIS, CE,RoHS & FCC Certified
Supply, Installation, Testing & Commissioning of HDMI extender set that should have a 2x1 auto switching HDBaseT 2.0 transmitter receiver set that supports the long distance transport of HDMI, VGA and High Speed USB 2.0 signals up to 100 meters / 330’ using category cabling. The set should be 4K compatible with a max resolution of 4K@60Hz / 4:2:0 8bit deep color.The receiver should features integrated 4 port USB 2.0 high speed device hub. An additional analog audio pass through input should be located on the wall plate that allows for audio distribution to the HDBaseT receiver side. With 48V integrated PoH, the set can be powered via HDBaseT receiver with a PSE module or the wall plate can be powered by a local power supply. The set should give you the ability to automate the display power ON by using pre-loaded RS232 commands whenever a video signal is introduced to the system using either the HDMI or VGA input. It should also turn the display power OFF after a specified amount of time has passed when no video signal is present.
Supply, Installation, Testing & Commissioning of 4x2 HDMI 2.0 Auto-switcher, 4K60 4:4:4 / HDR 18G Matrix switcher with audio de-embed, ARC, IR, & RS232 control, Auto-switch or manual switch between four HDMI inputs, 1x HDMI and 1x 3.5mm TRS audio (ARC & audio de-embedding) output Front panel, Supports resolutions up to 4k@60Hz, 4:4:4. 8 bit deep color, Supports HDR formats, HDCP 2.2 compliant, Supports EDID management, Supports CEC pass through control of source / display
Supply, Installation, Testing & Commissioning of eight input by eight output HDMI 2.0 matrix switcher with HDCP 2.2 support and capable of handling resolutions up 4K@60Hz 4:4:4 / 8 bit color with static and dynamic HDR output support for each channel. The matrix features advanced independent EDID management control for each HDMI input as well as an Easy EDID analyzer. The analog and digital audio outputs can be set to follow the HDMI video route or can be independently routed either by API or web control interface. Built in re-clocking circuitry ensures the switcher is backwards compatible with sources with older HDMI version chip sets. The matrix switcher can be controlled via front panel buttons, front panel IR, external IR, remote IR, RS232, and Ethernet. The matrix includes a simple IR remote control to allow IR switching. The matrix also features a full command set for RS232 and Ethernet control with third party control systems, plus control via web user interface.
Supply, Installation, Testing & Commissioning of HDMI extender set that should have a 2x1 auto switching HDBaseT 2.0 transmitter receiver set that supports the long distance transport of HDMI, VGA and High Speed USB 2.0 signals up to 100 meters / 330’ using category cabling. The set should be 4K compatible with a max resolution of 4K@60Hz / 4:2:0 8bit deep color.The receiver should features integrated 4 port USB 2.0 high speed device hub. An additional analog audio pass through input should be located on the wall plate that allows for audio distribution to the HDBaseT receiver side. With 48V integrated PoH, the set can be powered via HDBaseT receiver with a PSE module or the wall plate can be powered by a local power supply. The set should give you the ability to automate the display power ON by using pre-loaded RS232 commands whenever a video signal is introduced to the system using either the HDMI or VGA input. It should also turn the display power OFF after a specified amount of time has passed when no video signal is present.
Supply, Installation, Testing & Commissioning of HDMI 2.0 HDBaseT Extension Set, Extend HDMI 2.0 signals up to 4K@60Hz / 4:4:4 up to 70m (4K 40m / 1080P 100m), Complete set Includes TX, RX, power supply, and IR flasher/emitter, Extends bi-directional IR. Flexible PoC (Power on either end), Supports HDR10, HDCP 2.2 compliant, Flexible power design (use power supply at TX or RX)
Supply, Installation, Testing & Commissioning of UHD Video Conferencing System with 20x Optical PTZ Camera - Phone HD, Dual Display, 4K60 - 1+24 Multipoint 4K license with three year warranty. The system should be of resolution 3840 x 2160 progressive scanning up to 30 frames per second from day one. The system should be able to do Presentation data sharing up to 3840x2160p30. The system should have Bitrates and resolutions (H.264 High Profile). The System should have HD Speaker phone, with inbuilt microphones and touch screen for ease of use from same OEM. The video conference system shall support both H.323 and SIP. The Camera should be 4K UHD Camera. The Camera should have 20x zoom . The system should support Opus, G.722.1 (licensed from Polycom®), G.722, G.711 uLaw and aLaw, Siren 7. Should be supplied with standard accessories as required.
Supply, Installation, Testing & Commissioning of a Audio Conference Server with the below specifications : Max. Conference Microphones: 800, Frequency Response: 20 - 20kHz, Dynamic Range: >85 dB, Auto PC Software for a controlled meeting, Anti-feedback control, Audio Inputs & Outputs to connect to the amplifier, speaker and microphone systems
Supply, Installation, Testing & Commissioning of Chairman unit with the below specifications:- 3-button Voting Options, Built-in Spekaer system & headphone output. Includes (1) 18" Gooseneck Microphone (true condenser, super-cardioid)
Supply, Installation, Testing & Commissioning of a Delegate Unit with the below specifications:- 3-button Voting Options, Built-in Spekaer system & headphone output. Includes (1) 18" Gooseneck Microphone (true condenser, super-cardioid)
Supply, Installation, Testing and Commissioning Wireless Handheld Microphone System, Wireless Microphone system with MHZ carrier frequency band, Up to 16 pre-programmed frequencies within the same frequency band, Audio bandwidth 35 - 20,000 Hz THD at 1 kHz: <0.3% (Receiver) , Signal-to-noise: 120 dB(A) ( Receiver), Wideband FM Modulation, Up to 48 Simultaneous channels , up to 14 hours operation with one single AA battery or better, Pilot Tone, transmission to know the transmitter battery status, Receiver should have microphone level and line level output, Transmitter should have display to show the battery and LED to show the Muted /Unmuted status Sensitivity 6.3 dB V / -100 dBm, Should have Microprocessor-controlled diversity, T.H.D.: 0.7 % (Transmitter), Infrared programmable, RF output power: 10 or 50 mW With Twin Channel True Diversity Wireless Receiver. offers users upto 16 simultaneous operating channels, over a PLL synthesized circuit and anti-interference support, True-Diversity dual channel receiver comes in a 19" rack size and can be mounted using the rack mount accessory. The RF range for the receiver is 100m (Line of Sight)
Supply, Installation, Testing and Commissioning Wireless Lavaliere Microphone System, Wireless Microphone system with MHZ carrier frequency band, Up to 16 pre-programmed frequencies within the same frequency band, Audio bandwidth 35 - 20,000 Hz THD at 1 kHz: <0.3% (Receiver), Signal-to-noise: 120 dB(A) ( Receiver), Wideband FM Modulation Up to 48 Simultaneous channels, up to 14 hours operation with one single AA battery or better, Pilot Tone transmission to know the transmitter battery status, Receiver should have microphone level and line level output, Transmitter should have display to show the battery and LED to show the Muted /Unmuted status, Sensitivity 6.3 dB V / -100 dBm, Should have Microprocessor-controlled diversity, T.H.D. 0.7 % (Transmitter), Infrared programmable, RF output power: 10 or 50 mW
Supply, Installation, Testing and Commissioning of 18" Gooseneck microphone with base, shall have a condenser diaphragm to deliver superior sonic performance. The diaphragms are specially tuned to provide a boost in the human vocal range. Frequency Response: 20 Hz - 17 kHz, Polar Pattern: Cardioid, Sensitivity: -36±3 dB* (15.8mV) 0dB =1V /Pa,1kHz, Max SPL : 140 dB, 1 kHz at 1% T.H.D.
Supply, installation, testing & Commissioning of Digital Interactive Podium in Metallic Frame with 21 inch Full HD (Electromagnetic + Capacitive) Interactive Display with Electromagnetic Pen, with Motorized Tilting of the Interactive Panel, with provision to install Gooseneck Microphone, Interactive panel, Keyboard Tray, Visualizer Tray and space to store AV equipment, Interactive display with full HD resolution of 1920x1080, Technology IPS LCD, Aspect ratio16:9, Brightness 250 cd/m2, Contrast ratio1000:1, Pen Type shall be Pressure-sensitive and cordless. Top connectivity plate with HDMI, USB x 2, VGA + Audio and Power socket for external Laptop connectivity, built-in 4 x 2 HDMI Matrix Switcher with 4K@60Hz (4:4:4, 8- bit) as well as support for 16-bit Deep Colour, HDR (High Dynamic Range), 3D contents, HD audio and other features defined by HDMI 2.0 specification and Audio De-embedded for internal connectivity. Shall have built-in 9 U Rack space to accommodate AV Equipment. Should be supplied with i5 Mini PC with Window 10 and Keyboard & mouse etc. as required.
Supply, Installation, Testing & Commissioning of DVD/Blu-ray Player with USB option etc. all complete.
Supply, installation, testing and commissioning of Wall Mountable Multidriver (8 or better) vocal range line-array column speaker. The louspeaker shall meet the following performance criteria: Frequncy Range (-10 dB) of 100Hz - 16 kHz or better. Long term power handling of 300 Watts or more. The Loudspeaker shall have a Max. SPL (Peak) of >=119dB with a senstivity of 88 dB SPL and a dispersion of 130° H x 20° V or better. The loudspeaker system shall have a norminal impedence of 8 ohms. Optional 70/100V OEM transformer module with tap settings shall be available.
Supply, Installation, testing and commissioning of high impedence Class D Dual zone amplifier with output power of upto 2x120W @ 70/100V. frequency response of 55 Hz - 20 kHz (+0/–3 dB, @ 1 W reference 1 kHz); THD <0.3% at rated power. Channel Separation ≤ –60 dBV (below rated power, 1 kHz), Dynamic range > 88 dB. Shall include priority override and Fire alarm interface, shall include necessary loudspeaker EQs.
Supply, Installation, Testing & Commissioning of Class D configurable amplifier with total 4 x 300W / 2 x 600W output power or better @ 4/8ohms, 70/100 Volt or mixed use operation; Frequency Response : 20Hz - 20kHz for LZ mode ;THD <0.04% at rated output complete with standard accessories as required.
Supply, Installation, testing and commissioning of Premium 12-Input 2-Bus Mixer with XENYX Mic Preamps and Compressors, British EQ and USB/Audio Interface, Built-in stereo USB/Audio Interface to connect directly to computer. 1 post fader FX send per channel for external FX devices, Main mix outputs plus separate control room, phones and 2-Track outputs, 2-Track inputs assignable to main mix or control room/phones outputs.
Supply, Installation, Testing and Commissioning of Control system have minimum 8 bidirectional RS232, 8 IR, 8 Relays and 8 GP/IO and 1 Ethernet port to control all the devices in the room. Should have inbuilt or external IR sensor/learner to learn IR commands The compatible relay controller to control the Projector screen up down should be supplied as a package (may be from same OEM of controller or different). Should have inbuilt processing power and internal storage to store and process the control program. Should be compatible with any (IOS/Android) wireless or wired Touch screen of any size. Additional ports if required can be added with minimum hassle. Should have the flexibility to add as many user interfaces as required. Should have embedded webpage for control port settings. Should have Status LED to check for Control/Connection status. It should have minimum 5 license each included for both iOS & Android application Certification: CE, ISO 9001, ISO 14001, OHSAS 18001. Extra component or equipment maybe added to match the complete specs. Should be supplied with standard accessories as required.
Supply, Installation, Testing and Commissioning of Wall & Table Mount PoE Touch Panel have 7” or more IPS color screen. Should have minimum 1280 x 800 resolution, brightness 4000cd/m2, contrast ratio 800:1, 16:10 aspect ratio Should have inbuilt Wi-Fi, 802.11 b/g/n/ac, Bluetooth 4.0 Should have capacitive touch technology. Should support Multitouch. CPU performance: 1.6GHz Quad Core, GPU, 2GB RAM, 16GB flash. Should be able to decode video format HEVC/H.265, H.264, H.263, MPEG–1/2/4, VC–1, VP6/8, RV8/9/10, AVS, MVC, Sorenson Spark, M–JPEG Should be able to encode/stream video format H.264, MVC, VP8, M–JPEG Should have front 2MP camera, HD 720p. Should have Ethernet port 10/100/1000Mbps PoE LAN. Should have inbuilt mic and speaker. Should be provided with table mount & wall mount kit. Secured Operation - Highly secured operation of applications using password protection, hidden control buttons and more. Red LED alert when camera is active. should be possible with Customized GUI using same OEM GUI Software. should support native integration of same OEM enterprise management software. Certification: CE, FCC, ROHS, REACH, ISO 9001, ISO 14001, OHSAS 18001. Extra component or equipment may be added to match the complete specs. Should be supplied with standard accessories as required.
Supply, Installation, Testing and Commissioning of Control System. Controller with Minimum 4 bidirectional RS232, 4 IR, 4 Relays and 4 GP/IO and 1 Ethernet port to control all the devices in the room. Should have inbuilt or external IR sensor/learner to learn IR commands. The compatible relay controller to control the Projector screen up down should be supplied as a package (may be from same OEM of controller or different). Should have inbuilt processing power and internal storage to store and process the control program. Should be compatible with any (IOS/Android) wireless or wired Touch screen of any size. Additional ports if required can be added with minimum hassle. Should have the flexibility to add as many user interfaces as required. Should have embedded webpage for control port settings. Should have Status LED to check for Control/Connection status. It should support PoE. It should have minimum 5 license each included for both iOS & Android application. Certification: CE, ISO 9001, ISO 14001, OHSAS 18001. Extra component or equipment maybe added to match the complete specs.
Supply, Installation, Testing & Commissioning of Programmable 8 Port Relay Module & 4 digital / analogue input module 0-24 Volts DC, low-voltage relay, 6 Watts Power @ 12Volts / 240 V, 44k Input Impedence with cables & connectors as required etc. all complete.
Supply, Installation, Testing & Commissioning of Recording, Streaming & Webcasting Hardware simultaneously, Built-in 4x HDMI & IP Inputs with 4x Line Inputs, 2x HDMI Outputs. The system should be capable to record upto any four inputs simultaneously in a single frame and as well as individual sources simultaneously. Should have minimum 1TB inbuilt storage and can be connected to local NAS storage. The system should be able to support minimum 3 unicast streams.The recorded files should have the option of time and date stamp. OEM should be CE, FCC, RoHS & BIS Certified
Supply, Installation, Testing & Commissioning of Full HD 1080p @ 60 frames per second PTZ Camera with minimum 22X Optical Zoom and FoV of minimum 57 deg, min 300 Presets.Camera should support simultaneous outputs through Ethernet, HDMI, Audio In and can be controlled In & Out & IP.Panning 360° continous, Tilting angle +15° to -90°. The tilting and panning speed of camera should be minimum 700° per second. Camera should support PoE and IR Distance: 150 meter, Quad (4) Simultaneous stream, EIS support, True multi shutter WDR 126dB, Noise Reduction, Smart defog, Shake & dry support, ONVIF S, G, M support, Face Detection & Object classification supported, Motion detection, object tracking, Built-in card upto 2TB Support, EM should be CE, FCC, RoHS, BIS, UL, NDAA, TAA Certified
Supply, Installation, Testing & Commissioning of 18 AWG (24/0.20mm) x 2 core ATC copper conductor, PE insulated, core twisted in a circular form, Inner sheathed with moisture Proof Polymer, braid shielded (80%) with ATC copper, outer Jacketed with Matt finish Rugged Flexible PVC.
Supply, Installation, Testing & Commissioning of Category 6A F/UTP EN Series 23 AWG 4 Pair Shielded Cable. Solid annealed bare copper conductors, High density polyethylene insulation, 4 pairs twisted in varying lays and cabled, Flame rated PVC jacket, TIA/EIA-568-C Category 6A, NEC CMR, CEC CMR FT4, RoHS compliant.
Supply, Installation, Testing & Commissioning of High−performance 35 ft cable that supports signals up to 4K@60Hz (4:4:4), Deep color Should have Gold Plated pins with 28 AWG.Flammability Rating should be CL3/FT4,: RoHS 2011/65/ EU
Supply, Installation, Testing & Commissioning of High−performance 50 ft cable that supports signals up to 4K@60Hz (4:4:4), Deep color Should have Gold Plated pins with 28 AWG.Flammability Rating should be CL3/FT4,: RoHS 2011/65/ EU
Supply, installation , testing and Commissioning of VGA with Audio cable (15 feet). High−performance cable with male 15−pin HD and 3.5mm stereo audio connectors at each end. Should have Gold Plated pins. Should have conductor 26 AWG 7/34 tinned copper All pins should be connected for DDC2 and EDID support. Should be maximum 0.35 inch in diameter. Outer Jacket should be HD polyethylene, Dielectric: Foam polyethylene. Compliance: UL: CL2, CSA: C(UL) CL2
Supply, installation , testing and Commissioning of VGA with Audio cable (35 feet). High−performance cable with male 15−pin HD and 3.5mm stereo audio connectors at each end. Should have Gold Plated pins. Should have conductor 26 AWG 7/34 tinned copper All pins should be connected for DDC2 and EDID support. Should be maximum 0.35 inch in diameter. Outer Jacket should be HD polyethylene, Dielectric: Foam polyethylene. Compliance: UL: CL2, CSA: C(UL) CL2
Supply, installation , testing and Commissioning of VGA with Audio cable (3 feet). High−performance cable with male 15−pin HD and 3.5mm stereo audio connectors at each end. Should have Gold Plated pins. Should have conductor 26 AWG 7/34 tinned copper All pins should be connected for DDC2 and EDID support. Should be maximum 0.35 inch in diameter. Outer Jacket should be HD polyethylene, Dielectric: Foam polyethylene. Compliance: UL: CL2, CSA: C(UL) CL2
Supply, Installation, Testing & Commissioning of IP CCTV Camera :Fisheye Camera 12 Megapixel True WDR & Day/Night H.265 1/ 2.3" CMOS sensor, ONVIF S, G, T, M IR - 15 meter, TLS 1.2 (256 bit cipher minimum), In-built storage 512 GB, Surface mount, Indoor/Outdoor, IP67, Nema 4X, IK-10, PoE Powered Fan should have UL, CE, FCC, NDAA & TAA Certified, No GB/T standard or protocol is allowed etc. all complete.
Supply, Installation, Testing & Commissioning of IP CCTV Camera: IP DOME (Indoor): IP DOME 5 Megapixel Total, Remote Focus & Day/Night H.265/MJPEG, Lens 2.7 ~ 13.5 mm, MFZ, P-IRIS, Triple streams, VBR, CBR, EIS, Noise reduction, Corridor pattern, Defog supported, True WDR 120 dB, IR - 50 meter, AI enabled object classification, Built-in Micro SD: 1TB, ONVIF S, G, T, M Power Supply 12 VDC / 24 VAC (50 / 60 Hz), PoE (IEEE 802.3 af, Class 0). IP67, IK 10 Housing should have UL, CE & FCC Certified No GB/T standard or protocol is allowed, etc.with AI based object analysis all complete.
Supply, Installation, Testing & Commissioning of IP CCTV Camera : IP DOME (Indoor): 1 /2.8” 2 Megapixel progressive CMOS · 2.7 mm – 13.5 mm,True day/night (IR-cut filter),H.265 True WDR 120DB , Triple streams, VBR, CBR, EIS, Noise reduction, Corridor pattern, Defog supported, IR - 50 meter, Support up to 1TB Micro SD card, Memory: 1GB RAM and 512MB Flash, PoE (802.3af) or 12 VDC support IP67 IK 10 Housing should have UL, CE & FCC Certified No GB/T standard or protocol is allowed , Onvif profile S, G, T & M etc.with AI based object analysis all complete.
Supply, Installation, Testing & Commissioning of IP CCTV Camera : IP Bullet : 1 /2.8” 2 Megapixel progressive CMOS · 2.7 mm – 13.5 mm,True day/night (IR-cut filter),H.265 True WDR 120DB ,Triple streams, VBR, CBR, EIS, Noise reduction, Corridor pattern, Defog supported, Support up to 1TB Micro SD card, Up to 70 m IR illumination range , PoE (802.3af) or 12 VDC support IP67 IK 10 Housing should have UL, CE & FCC Certified No GB/T standard or protocol is allowed , Onvif profile S, G, & T etc. with AI based object analysis all complete.
Supply, Installation, Testing & Commissioning of IP CCTV Monitoring, Recording & Streaming System: Control Room Equipments: Server Storage NVR for Main Control Rooms- Enterprise Storage Server Suitable for Up to 128 with min 20 HDD supports up to 360 TB , dual Hot swap redundant power supply should be built-in. Intel Xeon 3 with 32GB RAM, RAID 6 with Throughput of 1900 Mbps Connect - automatically finds, addresses and connects IP cameras, It must work on Windows and Linux platform and client application should work on MAC, Windows, Linux from workstation Video multi-streaming to optimize storage utilization and network traffic, It should support streaming live/recorded video up to 500 simultaneous PC clients etc. CE, FCC, UL certified all complete.
Supply, Installation, Testing & Commissioning of IP CCTV Monitoring, Recording & Streaming System: Control Room Equipments: VMS Software supporting upto 128 Cameras. The VMS shall support with minimum 512 nos of thick clients and 16 Web Client, 16 mobile clients per NVR PTZ Control, Remote Viewing, Remote Storage, Playback. Supports JPEG, AVI, WAV export formats, Hourly schedules, Email Notification. This includes Camera and Base licenses, simultaneous administration of all users on multiple NVRs, configuration of user authentication using LDAP/Active Directory features of the network, Single sign on support, support SSL and TLS protocols for encrypted communication, The VMS standalone player shall be able to authenticate that the video has not been tampered with using a keyed Hash Message Authentication Code (HMAC), The VMS software shall provide a configuration option to require 2 users enter unique passwords to authorize tasks involving the viewing of video. (2nd Reviewer) etc. all complete.
Supply, Installation, Testing & Commissioning of IP CCTV Monitoring, Recording & Streaming System: Hard Disk Special Surveillance 4TB 3.5" SATA HDD internal( For Servers) etc. all complete.
Supply, Installation, Testing & Commissioning of IP CCTV Monitoring, Recording & Streaming System: Control Room Equipments: Application server with Windows Server 2012 R2 (64bit) with Xeon Quad Processor and 1TB Hard Disk, 8GB Ram, 4GB Graphics Card, CD/DVD writer, with 2 HDMI port, 1 VGA port, 1 RJ45 10/100/1000 Mbps port, Mouse & Keyboard etc. all complete.
Supply, Installation, Testing & Commissioning of IP CCTV Monitoring, Recording & Streaming System: RJ-45 outlets near the cameras etc. all complete. Cat6 Field Termination Plug,IDC type Tool less,PC UL 94V-2 black,Contact material: Phosphor bronze with 100 micro inch nickel plated,Retention strength: 7.7 kg,Compliant with Cat.6, Class E requirements: ISO/IEC 11801 2nd Edition Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5 for camera ends only.
Supply, Installation, Testing & Commissioning of IP CCTV Monitoring, Recording & Streaming System: Media Converter SM/SFP Module etc. all complete.
Supply, Installation, Testing & Commissioning of IP CCTV Monitoring, Recording & Streaming System: LIU to Media converter connectivity etc. all complete.with 24 fiber Loaded LIU at all location , all passive from same OEM. Panels to b loaded with LC adapter and LC Pigtails and also Fiber Patch cords to connect to Media Convertor.
Supply, Installation, Testing & Commissioning of IP CCTV Monitoring, Recording & Streaming System: 8 port loaded fiber LIU box with pigtails and couplers etc.Fiber optic patch panel FMS Termination Drawer should have sufficient slots to accommodate 3 of 12/16 Port LC Adaptor Plates,Splice Tray of ABS, Comply with UL 94V2 material should be supplied with LIU.6 Duplex LC Adapters, SM, UPC with F/O Pigtail, LC, SM, G657A2, PC, LSZH, 1m,Height: 1 U, 1.75 inches (12 and 48 Ports),All LC adapters should be duplex type with shutter for protection. Adapters should be snap mount for easy insertion and removal,empty Slots of FMS should be covered with blank plates,Insertion Loss: <0.2 to <0.1 dB, RoHS Compliant all complete.
Supply, Installation, Testing & Commissioning of 55" 4K UHD(3840 X 2160) LED display, 500 Cd/m2, HDMI 2.0 X 4, DP X 1, VGA X 1, USB X 2, RJ45 X 1, RS232 X 1, Audio IN X1, Audio Out x 1, Digital Audio Out x 1, HDMI Out x 1, 20W in built speaker, 24/7 operation, Built in Wifi, Bluetooth, Auto wake up on Input, Auto switch on failover, HDMI CEC, No signal Power Off, SNMP Support, Crestron Connected, RS232 and LAN Control, USB Auto play function, Multi screen support upto 10 x 10, HTML 5.0 based browser, SOC etc. all complete.
Supply, Installation, Testing & Commissioning of Control Room Equipments: 42U RACK IT INDUSTRY STANDARD RACK with ventilation, sliding shelves, power strips etc. all complete.
Supply, Installation, Testing & Commissioning of Control Room Equipments: 6U RACK IT INDUSTRY STANDARD RACK with ventilation, sliding shelves, power strips etc. all complete.
Supply, Installation, Testing & Commissioning of Control Room Equipments: 5 KVA, ONLINE UPS etc. all complete.
Supply, Installation, Testing & Commissioning of Control Room Equipments 650 VA, ONLINE UPS etc. all complete.
Supply, Installation, Testing & Commissioning of 24 Port L2 Managed 10/100/1000 Mbps Switch, Rack Mountabl etc. all complete.
Supply, Installation, Testing & Commissioning of 24 Port Unmanaged POE 10/100/1000 Mbps Switch, Rack Mountable etc. all complete.
Supply, Installation, Testing & Commissioning of Cat 6 Unarmoured Cable for POE purpose. Cable length 305 mtr,Category 6 Unshielded Twisted 4 Pair 100 Ω cable shall be compliant with ANSI/TIA/EIA-568-C.2-1 Additional ISO/IEC 11801:2010 (Ed. 2.2) and ISO/IEC 61156-5,LSZH RoHS complied,Outer Diameter: 6.0 ± 0.2mm,Transmission Performance Specification for 4 Pair 100Ω Category 6 Cabling,Should be ETL certified and 4 Channel ETL Verified as per TIA 568-D-2018, UL Listed. All passive from one OEM ( RIT/Commscope/ Siemon/Panduit)
Supply, Installation, Testing & Commissioning of PVC Conduit diameter 25mm (as per actual) etc. all complete.
Supply, Installation, Testing & Commissioning of Armored Optical Fiber 6 Core Cable multimode,Should fulfill the requirements of ISO.IEC 11801 - 2nd Edition, type OS2, ITU-T REC G 652D spec IEC 60794-1-2 F5,Fibre/Tube Identification : Multi Tube,Thickness : 1.6mm,Central Strength Member: Steel wire coated with PE,Mass (Nominal) : 91 kg/km,Max. Tensile Strength-Short Term : 1500N, Max. Crush Resistance-Short Term : 2200N/100 mm,Fibre protection (Tubes) : Polybutylene Terephthalate (PBT) for switch to switch connectivity (as per actual) etc. all complete.
Supply, Installation, Testing & Commissioning of Accessories for Outdoor Junction Box For Field Devices. JB must be of appropriate size to house different components as per CCTV system design confirming to tender specifications. The junction box shall be provided with external earthing lugs 5 socket Power terminaton with MCB or More Proper/Steady fixing along with Pole (either through RCC base or weather proof clamping with pole) as per site requirements is under bidder’s scope etc. all complete.
acoustic work for audi & lecture hall
Fabric wrapped Compressed glass substrate panels paneling on rear & side walls : Providing and fixing Acoustical Wall paneling with square edge panels made of fibre glass substrate 25mm thick with a density of 120kg/m3 and meet the fire class A wrapped on the front side with an acoustical fire retardant fabric which will meet fire test of BS EN 1021 and IS: 1561-2002 and minimum weight of 340GSM with an option of colours as per the choice of the person-in-charge, of size1200mmX600mm with an NRC of upto 1.0 . The panels to be pasted with approved construction adhesives over 9mm thick ply . The 9mm thick ply shall be fixed over GI framing consisting of 48x36x34x0.5mm thick GI Studs wall channels & floor channels @ 600mm c/c.
Wood grained wooden perforated sound absorb slit paneling for rear wall, side walls & stage front: Providing and fixing Wood melamine finish high density fiberboard based panels with slit perforations of size 14x40mm to be fixed on walls.The panels shall be with melamine laminate finish of size 1220mm x 610mm x15mm thick having density of 800kg/m3 which will comprise of NRC 0.75 and meet the fire test class 1&P . The back of the panels are with a nonwoven fabric covering of 0.2mm for providing Sound absorption via the acoustic impedence method.Panel is to be fixed on GI framework as recommended by the manufacturer with screw fixed horizontal / vertical on GI framework. The cavity of framework should be inserted with 50mm thick, 1000 GSM polyester wadding.
Ceiling With Micro-perforated 3x3mm Square Gyp Acoustic Board:- Providing & fixing Micro perforated Gyp acoustical ceiling , as marked in the drawings, consisting of GI perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending GI intermediate channels of size 45mm (0.9mm thick with 2 flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angles of width 25mm x 10mm x 0.55mm thick fixed to soffit with GI cleats and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clips and in a direction perpendicular to the intermediate channel at 300mm c/c. The polyester fibre of 1000 gsm density and 50mm thick layed over the made framework and Finished in 12.5mm thick micro-perforated gypsum board of size 1200mm x 2400mm, with 3x3mm square perforations having fire class A2-s1,d0 (C1) ( A2- Non combustible, s1- Minimum Smoke, d0- No droplets, Fire rating- Class1) and tested to meet the safty requirements of EN 14190 in combination with 12.5mm thick plain gypsum board where ever required. The board to be finished with 2 or more coats of mat type plastic emulsion paint after proper jointing & making surface smooth. All complete as per drawing & design.
Wooden Slats Ceiling- Providing and fixing Slated Wooden Acoustic panel with lineal perforations to be fixed on walls.The panels shall be with melamine laminate finish of size 2430mm x 128mm x15mm wirh 4mm slats at 28 mm pitch, Toungue and Groove edges . The back of the panels are perforated with 10mm diameter circular holes with a nonwoven fabric covering of 0.2mm for providing Sound absorption via the acoustic impedance method.Panel is to be fixed on GI framework as recommended by the manufacturer with screw fixed horizontal / vertical to wall at every 600mm c/c with centre & edge bracket in tongue & groove system on GI framework. The cavity of framework should be inserted with 50mm thick 48Kg density rockwool Make Deftech
Stage suspension Grid: Providing & fixing MS suspension grid system over stage for hanging stage services made of 2 nos 40x40x5mm MS angles welded back to back with 50x12x12mm thk studs as MS spacers sandwiched between the MS angles so as to maintain 12mm gap between MS angles, the welded angles to be placed @ 1200mm c/c in one direction and 40x5mm thick MS Tee @ 600mm c/c in other direction. The MS grid to be suspended from the roof structure by means of MS flat suspender of 50x6mm thick MS flats @ 1200mm c/c in both directions. All MS members to be painted with a coat of red oxide primer & 2 or more coats of black enamel paint.
Woodwool fibril acoustical tiles in stage ceiling: Providing and fixing Fibril wood-wool black acoustical tiles of size 1200x600x20 mm to be installed existing MS suspension grid. Which will comprise of NRC 0.80 and meet the stringent fire test required having Class ‘P’ rating for Ignitability test as per BS 476 part 5 and Class ‘1’ rating as per BS 476 part 7 for Surface Spread of Flame test and density of 400kg/m3. Approved make: Absound Overseas / Herra Design / Acoustic India.
UPVC Fabric Stretch Paneling on rear & side walls : Providing & fixing Acoustical wall paneling in Stretched fabric system consisting of FR grade fabric which will meet fire test of BS EN 1021 and IS: 1561-2002 and minimum weight of 340GSM of reqd. colour. 19mm UPVC grippers fixed over 50x12mm thick ply strips on GI frame consisting of 50mm th. GI Stud wall channels & floor channels filled with 50 mm thick 1000GSM thermally bonded polyester wadding .The insulation to be covered from back by covering the frame with 19mm GI wire netting. Approved Make : Absound Overseas / Acoustic India / Anutone.
Stage Walls treatment : Providing and fixing 25mm thick, carpeted fabric wrapped fibril wood wool panels having density of 400kg/cum and meet the stringent fire test required having Class ‘P’ rating for Ignitability test as per BS 476 part 5 and Class ‘1’ rating as per BS 476 part 7 for Surface Spread of Flame test. The Panel will be fixed over a framework of GI channels consisting of 48x36x34x0.5mm thick GI Stud wall channels & floor channels @ 600mm c/c, filled with 50 mm thick 500GSM thermally bonded polyester wadding to be held in position with 19mm GI wire netting. The panels to be fixed with H-spline system over GI framing. Approved Make : Herra Design/ Acoustic India/ Absound Overseas.
Supply and fixing of 83mm thick, 38 dB acoustic cum fire check door shutters having fire rating of 120 minutes with infill of 47 mm thick resin bonded glass wool (24kg/cum density) coated with FR Acrylic Sealant Sandwiched between two 9mm thick calcium silicate boards of (100% calcium silicate) without asbestos, brucite and meerschaum with density 1150 gms/cum, thermal conductivity 0.14W/M*K, faced with 8mm thick commercial ply on both sides and having teakwood lipping of size 15x89mm on all four edges. The work is to executed as per direction of architect or engineer-in-charge. Make : Global Fire/ Navair/ Absound Overseas.
Building ID Signage
Providing & fixing at all heights and locations Letters made up of Stainless steel, grade 316 of approved make made out of laser cut shape in required design, language & font, including buffing, polishing and fixing by sufficient numbers of fastener high quality chemical tape/ adhesive/fast of approved make, all complete as per architectural drawings and direction of Engineer in charge.
Casualty (Hindi+English) Both Side of Porch
Government Medical College & Hospital (Hindi+English)
Block A,B,C
Internal Signage
Providing and Fixing area specially text and graphic signages made out of 18 gauge stainless steel sheet brushed finish as per IS 304, Finish. The text and graphics finished with deep engraved by acid etch silk screen photo process duly filled in stove enamel paint of approved colour and shed the plate should be fixed to be required nos. of stainless steel star screws /3M double side foam adhesive where required directed by the engineer-in-charge.
Room No.
Bed No.
Drinking Water
Washroom Male
Washroom Female
Washroom Specially Abled
Push and Pull
Providing & fixing at all levels and locations, informatory/ directional/warning signages in required font, design, pattern and size made of 4 mm thick odorless Acrylic sheets of make Cast/ Acrylite/ or approved equivalent, conforming to specific gravity of 1.19, tensile strength of 69 MPA, percentage elongation of 4.2 %, modulus of elasticity 2800 MPA (ASTM –D638), refractive index of 149, (ASTM-D542) Rockwell hardness of M94 (ASTM – D785), water absorption of 0.2 % (ASTM- D570) total light transmission of 92 % (ASTM – D 1003) chemical, UV & weather resistant, having excellent insulation properties, abrasions resistant of approved colour,of approved quality and make, with bevelled edges having self adhesive self luminescent vinyl sheet ( film thickness >150 micron, luminescent duration 4-6 hours) of make 3M/ Avery or approved equivalent over which the signage/ letter cuttout made of vinyl sheet ( film thickness > 80 micron) of make 3M/ Avery or approved equivalent is pasted in required colour, font, design, pattern, including fixing over walls/ partition/glass etc, fixing by high quality chemical tape of make 3M/ Avery or approved equivalent on prepared surface, all complete as per architectural drawings and direction of Engineer in charge.
Name Plate, Designation Plate
Department Name Plate i.e. X-Ray, Ultrasound, OPD, ICU, OT, MRI, Lab, Etc.
Floor No., Lift Name, Staircase, No Smoking (Hindi+English), Bhawan ko saaf suthra
Emergency Exit, Exit/Nikas
Floor Directory, Chetavani (Hindi), Fire Evacuation Map
Lift Disclaimer, Fire Hose Reel, Fire Hydrant, Danger Sign
Electrical Panel Room, Lift No., Restricted Area, AHU, Keep Silence, No Spiting
Fire Alarm
Designing Providing and Fixing of Pylon both side dimension of pylon 1828x610x100mm made with MS Tube 50x50x2mm structure with MS base plate 150x150x8mm 2nos. including cladding of 4mm thick ACP sheet all around the Pylon with help of double side 3M tape including providing pressure pasting of printed vinyl 3M/Avery 180-C Grade & over laminated of approved brand vinyl fixed by Dash Fastener Hilty/Fisher complete as per architectural drawings and direction of Engineer in charge.
Supply, Installation, Testing and Commissioning of Medical Gases Pipeine System as per NFPA -99 guidelines.
Oxygen System
15+15 size manifold extendable type complete with middle frame with chain for individual cylinder (bulk cylinder D-type) along with Non-Return Valves for every cylinder and copper tail pipes .
Fully Automatic Digital Gas Control Panel for Oxygen with inlet for Liquid Oxygen Tank as per NFPA 99, -
6 + 6 Cylinders Emergency Oxygen Manifold with two stage High flow rate regulator with NRV for every cylinder and copper tail pipes as per specifications.
Terminal Units (Gas Outlets) with probes/Adaptors as per NFPA, CSA UL Listed as per NFPA 99, -
Oxygen Flowmeter with Humidifier Bottle .
H.P Tubing Flexible having antistatic Core as per ISO with Proper colour coded .
Nitrous Oxide System
4 + 4 size manifold extendable type complete with middle frame with chain for individual cylinder (bulk cylinder D-type) along with Non-Return Valves for every cylinder and copper tail pipes .
Two Cylinder Emergency N2O Manifold with two stage High flow rate regulator with NRV for every cylinder and copper tail pipes .
Fully Automatic Control Panel for N2O .
Terminal Units (Gas Outlets) with probes/Adaptors as per NFPA, CSA UL Listed as per NFPA 99, -
H.P Tubing Flexible having antistatic Core as per ISO with Proper colour coded .
Compressed Air System
The unit should have triplex stationary air cooled silenced (Reciprocating) Oil-Free Air Compressor with critical maintenance free technology each having 57.18 scfm capacity.
3-Stage Breathing Air Filters
Air Receiver Tank
Terminal Units (Gas Outlets) with probes/Adaptors as per NFPA, CSA UL Listed as per NFPA 99, -
For 4 bar
For 7 bar
H.P Tubing Flexible having antistatic Core as per ISO with Proper colour coded as per Technical Specification
Vacuum System
Qudraplex 7V Vacuum Pumps of Ingersoll with Motor each with receiver vessel, with bacteria filter capacity.The system to provide duplex/cascade vaccum system for automatically start and stop at 480mm and 650 mmHG
Vaccum Tank reservoir
Bacteria Filters
Terminal Units (Gas Outlets) with probes/Adaptors as per NFPA, CSA UL Listed as per NFPA 99,
Ward Vacuum Unit with Regulator, Collection Jar of 600 ml with bracket .(For Wards)
Ward Vacuum Unit
H.P Tubing Flexible having antistatic Core as per ISO with Proper colour coded .
Combined Electrical Control Panel for Compressed Air System and Vaccum System .
Copper Pipes used will be solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased, manufactured as per EN 1057 part I, Table-X of 1971 and chemical composition as per BS-6017 of 1981, Table 2, Cu-DHP.,Kite Marked.
76 mm OD X 1.5 mm thk
54mm OD X 1.2mm thk
42mm OD X 1.2mm thk
28mm OD X 1 mm thk
22mm OD X 1 mm thk
15mm OD X 1 mm thk
12mm OD X 1 mm thk
Valves Boxes with Pressure Gauges
6 Gas Services(O2,Vac,N2O,Air4,Air7,AGSS)
4 Gas Services (O2, Vac, N2O, Air 4 )
3 Gas Services ( O2, Vac, Air 4)
2 Gas Services ( O2, Vac, Air 4)
Area Alarm
6 Gas services(O2,Vac,N2O,Air 4,Air 7,AGSS)
5 Gas Services (O2, Vac, N2O, Air 4, Air 7, )
4 Gas Services (O2, Vac, N2O, Air 4, )
3 Gas Services ( O2, Vac, Air 4)
2 Gas Services ( O2, Vac, Air 4)
Isolation Valves
MASTER ALARM
Bed Head Panels
Anesthesia Gas Scavanging System Oil Less Contactless Rotary Claw, Tank Mounted Duplex System should be fully compliant for use in Medical AGSS System. The unit should consist of four electric motor driven pumps vacuum receiver, electrical control system and interconnection piping and wiring. Design Capacity SCFM@ 19"Hg/Capacity of each pump is 39 / 39 with 5 HP Motor & Tank Size 120 gallons .
Medical Gas Terminal/Outlet points for AGSS. (CE MARKED)
FURNITURE WORK
Reception Area
Reception Table :- W2400xL1800xL1200xD600mm
Providing and Supplying Reception Table HNI Make. The Worktop at 750mm Height is 600 mm Deep. Reception Table has 300mm Depth Table Top Fixed on Top of frame. The Thickness of this Counter Top is 25mm . The Frame Height is 1200mm and is 50 mm thick and made of Aluminium Extrusions of 1.2 mm to 1.5mm thickness. The System is complete hollow system with space for wire reticulation . All the frames will be duly powder coated . All the frames are fastened together by means of M6 NUTS & BOLTS . All the frames are fitted with M10 leveling bolts.board.The Raceway :-The raceway cover are sliding type and are integrally fitting inside frame and are made out of 0.8mm - 1mm thick CRCA steel & powder coated. The electrical raceway can be provided below worktop or above worktop.The partition has two integrated raceway provided one at skirting level and another at the work surface level thus ensuring separation of power and networking cables. The free space available within raceway accommodates power, data and communication cables. The cable can be taken into the Frame from the floor from the bottom. Tiles: Fabric Tile: Constructed out of 5mm thick Medium Density Fiber Board (MDF) and covered with Fabric of choice. Laminate Tile: Made out of 5mm - 8mm thick Pre-laminated Medium Density Fiber Board (MDF) Bottom Row of Steel Tile: Constructed out of 0.8mm CRCA sheet and finished in epoxy powder coating. Can be given with plain / perforations / embossed finishes. Table tops and Gable ends are of 25mm thk Pre-laminated particleboards conforming to IS : 12823 Interior Grade. All Worktops to have Metal Insets for fixing screws. Specially designed powder coated M.S. brackets having 2mm thickness fixed to the partition frame support the tabletops. Gable ends are of 25mm thk. both side laminate (BSL) with 2mm PVC edge banding on front side. Gable Ends are fixed with 3mm thick MS brackets to Frame and with 3mm thick Brackets to Worktops. Sealed edge in table top and gable ends are with2mm thick PVC edge banding on Working side and 0.8mm thick edge banding on non working side. Reception Table has 3Drawer Pedestal unit of size 400mm L x 450mm D x 680mm made up of 18mm thk. Prelam particle board conforming to IS : 12823 Interior Grade with 3 Drawer ( 2 Drawer + 1 Filing ) with roller slide mechanism for 2 Drawers and Ball bearing slide for 1 Filng Unit
Chair
Libro MB Back Height - Medium Back Back Finish - Mesh with adjustable lumbar support Back Frame - Black Color Seat Finish - Fabric - Black Seat Height Adjustment - Pneumatic Mechanism - Synchronized Tilt Back Tilt Lock - Upright Position Back Tilt Tension - Adjustable Armrests Type - 1D Height Adjustable Armpads Type - Metal Base Type - 5-Star in Nylone Base Warranty : 3 years from the date of invoice
Office Room/Back Office
Workstation :- W1500xD600xH750mm
Workstation :- W2650xD600xH750mm
P/S Modular Workstation of size as mentioned below, Desk Based System of Height 1050 mm. The Legs are made of 50mm x 50mm Sections of Steel duly powder coated. The Understructure has CRCA Steel Powder coated Raceway with seperate . Raceway is trapizium shaped ,110mm Height and 80-170mm Wide and runs along the entire Length of the Worktop. The slots for switches and Sockets are provided on Raceway cover as pe the use requirement. The raceway cover is also CRCA Steel Powder coated. Steel Powder coated Cross Beams are running under each Worktop. Cross Beam has Dimension 50mm Ht x 25mm W . The workstations have 18mm Fabric wrapped MDF Privacy Panel fixed on Elegent Metal Hardware to the worktop. The height of Privacy Panel is 300mm above worktop . All steel parts shall be pretreated for seven stage anti-corrosion treatment followed by epoxy powder coating. The thickness of the powder coating for all the steel and aluminium parts shall be minimum 45microns. The worktop shall be made of 25mm thick Prelaminated Particleboard. The Worktops should have metal inserts on underside for modularity. The screw used should be blunt headed and not sharp headed for metal to metal coupling . All exposed/unexposed edges shall be finished with hot melt PVC edge banding of 2mm thickness on working edge and 0.8mm on non working edges. Each workstation shall be provided with a wire manager cutout of 65-70mm diameter .Worktops shall be provided with necessary prefixed M6 metallic inserts for fixing the brackets to the worktops for metal to metal coupling for complete modularity.
Pedestal
Laminate pedestal unit having Dimension 400mm W x 450mm D x 635 Ht and shall consist of One pencil tray, 2 drawers and one filing box. It is made of 18mm prelaminated particle board . It shall be provided with 2 lockable and two free twin wheeled castors. The pedestals shall have central locking mechanism. It has roller slide mechanism for 2 Drawers and Ball bearing slide for 1 Filng Unit.The pencil tray shall be made of 2mm moulded HIPS and shall be fitted inside the first drawer. It should freely slide in horizontal direction. The pencil tray shall have necessary compartments (Miniumum 3 compartments) for keeping stationary items.
Chair
Libro MB Back Height - Medium Back Back Finish - Mesh with adjustable lumbar support Back Frame - Black Color Seat Finish - Fabric - Black Seat Height Adjustment - Pneumatic Mechanism - Synchronized Tilt Back Tilt Lock - Upright Position Back Tilt Tension - Adjustable Armrests Type - 1D Height Adjustable Armpads Type - Metal Base Type - 5-Star in Nylone Base Warranty : 3 years from the date of invoice
Storage :- W1200xD450mmxH1200mm
Providing and placing HNI Trent Prelaminated Particle Board storage with openable doors of 1200mm(ht), made up of 18mm thick prelaminated particle board with PVC edge banding and locking arrangement.Storage body is made of 18mm thick pre laminated partical Board conforming to IS : 12823 Interior Grade.The back of the unit is made from 18mm prelaminated board. All the exposed edges are with 2mm PVC egde Imported banding & sealed edges are with 0.8mm thick PVC Imported edge banding. The top, side and hinged shutters are sealed with 2mm thick PVC edge banding. Storage has adjustable shelves inside and cam lock, tower bolt and locking strips.The units are assembled by knock down fittings such as Minifix & Dowels. All the hardware and Hinges are from Hettich/Ebco. Storage has Brushed SS finish handles and lock . Prelam storage unit of 1200mm ht and 450mm depth .
Waiting Area
3 Seater Metal Perforated Steel Sofa
4 Seater Metal Perforated Steel Sofa
Providing and Supplying HNI Metal Waiting chair Model ES 909 having Seat made of Perforated Cold Rolled Steel Epoxy Powder coated having thickness of 1.2mm . Arms and Legs are made of Aluninium for superior Strength and durability. Seat Seat Frames are supported on Steel Beams with thickness of 2mm duly powder coated. Seat and Back are single piece duly Epoxy powder coated.
Nurse Stations
Nurse Station :- W4650xD600mm
Providing and Supplying Nurse Station Table HNI Make. The Worktop at 750mm Height is 600 mm Deep. Table has 300mm Depth Table Top Fixed on Top of frame. The Thickness of this Counter Top is 25mm . The Frame Height is 1200mm and is 50 mm thick and made of Aluminium Extrusions of 1.2 mm to 1.5mm thickness. The System is complete hollow system with space for wire reticulation . All the frames will be duly powder coated . All the frames are fastened together by means of M6 NUTS & BOLTS . All the frames are fitted with M10 leveling bolts.board.The Raceway :-The raceway cover are sliding type and are integrally fitting inside frame and are made out of 0.8mm - 1mm thick CRCA steel & powder coated. The electrical raceway can be provided below worktop or above worktop.The partition has two integrated raceway provided one at skirting level and another at the work surface level thus ensuring separation of power and networking cables. The free space available within raceway accommodates power, data and communication cables. The cable can be taken into the Frame from the floor from the bottom. Tiles: Fabric Tile: Constructed out of 5mm thick Medium Density Fiber Board (MDF) and covered with Fabric of choice. Laminate Tile: Made out of 5mm - 8mm thick Pre-laminated Medium Density Fiber Board (MDF) Bottom Row of Steel Tile: Constructed out of 0.8mm CRCA sheet and finished in epoxy powder coating. Can be given with plain / perforations / embossed finishes. Table tops and Gable ends are of 25mm thk Pre-laminated particleboards conforming to IS : 12823 Interior Grade. All Worktops to have Metal Insets for fixing screws. Specially designed powder coated M.S. brackets having 2mm thickness fixed to the partition frame support the tabletops. Gable ends are of 25mm thk. both side laminate (BSL) with 2mm PVC edge banding on front side. Gable Ends are fixed with 3mm thick MS brackets to Frame and with 3mm thick Brackets to Worktops. Sealed edge in table top and gable ends are with2mm thick PVC edge banding on Working side and 0.8mm thick edge banding on non working side .
Chair
Libro MB Back Height - Medium Back Back Finish - Mesh with adjustable lumbar support Back Frame - Black Color Seat Finish - Fabric - Black Seat Height Adjustment - Pneumatic Mechanism - Synchronized Tilt Back Tilt Lock - Upright Position Back Tilt Tension - Adjustable Armrests Type - 1D Height Adjustable Armpads Type - Metal Base Type - 5-Star in Nylone Base Warranty : 3 years from the date of invoice
Case demonstration
Trainer Table :- W1500xD750mm
Providing and Supplying HNI Make Office Table having Dimension 1500mm L x 750mm W x 750mm Ht. Worktop is made of 25mmthick PLPB of Grade II, Type II conforming to IS:12823: 1990 and having 2mm thick pvc edge lipping, Understructure is made of 18mm thick PLPB of Grade II, Type II conforming to IS:12823: 1990 and having 2mm thick pvc edge lipping .Three no Drawer is built into the table. The Drawers have lock and each drawer is provided with Pull out Handle. 5 Year Warranty.
Trainer Chair
Libro MB Back Height - Medium Back Back Finish - Mesh with adjustable lumbar support Back Frame - Black Color Seat Finish - Fabric - Black Seat Height Adjustment - Pneumatic Mechanism - Synchronized Tilt Back Tilt Lock - Upright Position Back Tilt Tension - Adjustable Armrests Type - 1D Height Adjustable Armpads Type - Metal Base Type - 5-Star in Nylone Base Warranty : 3 years from the date of invoice
Desklet chair
Seat is made of Injection molded polypropylene. Seat is attached to the frame by the back attachment and with two steel Pal-nuts . Backrest is also made of Injection molded polypropylene. Attached to the frame with two metal clips. Contains a contoured handle opening at the top for easy lifting and stacking.Chair Frame Construction - Welded construction made primarily of 7/16" diameter steel wire (solid) bent to shape on a CNC wire bender. A 7-gauge steel seat strap, ribbed for added strength, supports the front of the seat and a 7/16" contoured steel rod joins the front legs for strength. Frame Finish - Bright chrome plated finish with duplex (semi-bright) nickel, bright nickel and chrome applied. Nickel provides corrosion resistance. Tablet arm is designed for easy attachment and removal. Brackets on the tablet arm just hook/snap on the chair frame. Tablet surface is hinged for easy access into the chair. Tablet frame is a welded construction made of 7/16" diameter steel wire bent to shape and two 11-gauge brackets. Finish is bright chrome only. Tablet surface has a plywood core with a highpressure laminate surface on the top and a backer sheet on the back. The edges are round with a clear lacquer finish and 5/8" overall thickness. Chairs are non-stacking when tablet arms are attached. Warranty - 5 Years . Makes IMAGO
Immunization Room/child Welfare/speech & Occupational Therapy/child Rehabilitation/consultation&examination/e.c.g Room/plaster Room/dressing Room/treatment Room/nurses Room/doctors Room/prosthetic Dentistry/sterility Clinic/refraction Room/H.O.U/senior Resident Doctor/deppt Office / Non Teaching Staff/tutor Room/demonstration Room/assistant Professor /lecturer /student Duty/surgeons Room/Polic Office/Associate Professor /Reader/Tutor Room/Anesthtic Room
Main Table :- W1500xD750xH750mm With Side storage :-W900xD450mm
Providing and placing HNI Make "Trent" , Main Table 1500 x 750mm, completely made up of Postform Curvica particle board conforming to IS : 12823 Interior Grade with PVC edge banding. Top are with 25mm thk boards with post formed Edge on User and Visitor Side .The Worktops should have metal inserts on underside for modularity. The screw used should be blunt headed and not sharp headed for metal to metal coupling . Table top is supported on 18mm thick Gable ends and 18mm thk Modesty panels. exposed edges are in 2mm thk PVC edge banding & sealed edges are in 0.8mm thk PVC edge banding. Separate provision for mounting switches on the wall adjoining the tables shall be made by customer as the tables do not come with switch mounting facility. Side storage :-W900xD450mm . Side Storage unit is made of combination of hinged door unit and 3 Drawer unit - Storage body is made of 18mm thick pre laminated partical Board conforming to IS : 12823. The back of the unit is made from 18mm prelaminated board. All the exposed edges are with 2mm PVC egde Imported banding & sealed edges are with 0.8mm thick PVC Imported edge banding. The top, side and hinged shutters are sealed with 2mm thick PVC edge banding.Storage has adjustable shelves inside and cam lock, tower bolt and locking strips. The units are assembled by knock down fittings such as Minifix & Dowels. All the hardware and Hinges are from Hettich/Ebco.
Main Chair
Providing and supplying HNI Model Quip High Back Chair with head rest .This is a High back chair with Mesh Back with back tilt tension adjustable . The chair mesh is available in 6 different colours ( Green / Ruby / Cinnamon / Magenta / Indigo / Black ) with matching or contrast seat fabric according to the choice of the client..The chair has Adjustable Lumber Support . The Chair has Nylon base with 60 mm twin wheel castors .Chair has 1-D adjustable armrests with PU Pads . Seat size is 490 mm W x 435 mm D and the Chair Height 1135mm - 1225mm . Overall size of the chair is 640mm W x 665mm D x (985 mm- 1220mm) H .The chair has Pneumatic Gas Lift with Stroke=85 mm . Chair carries a warranty of 5 years.
Visitor Chair
1. Leatherette Upholstered Seat & Back 2. Seat Size-530 mm W X470 mm D 3. Back Size – 530 mm W X460 mm HT 4. Base - Powder Coated fixed Base 5. Overall Chair Size - 618 mm W X 615 mm D X 815 mm H
Stool
Providing and Supplying Lab Stool with Seat Dia minimum 30 cm. The seat should be made up of 12mm thick hot pressed plywood upholstered with fabric / Leatherite and moulded polyurethane foam. Chair should be on a 4 legged Metal Pipe frame assembly with Height adhustability for seat and is duly powder caoted and provided with gliders as per manufacturer's specifications, drawings & direction of Engineer in charge. The above furniture should be as per specification and sample approved by client.
2 Seater Sofa
Providing & Fixing of sofa . The inside frame is made of seasoned wood and has antitermite treatment. The seat and back are made of foam and is finished in leatherite upholestry. The Frame base has Webbing for Supporting the Cushions. The Complete Sofa Body has Polyurethane Foam in desired shape. The Sofa is supported on Metal Chrome Plated Legs. Leatherite colour and type as per directions of Engineer in Charge.
Storage :- W1200xD450mmxH1200mm
Providing and placing HNI Trent Prelaminated Particle Board storage with openable doors of 1200mm(ht), made up of 18mm thick prelaminated particle board with PVC edge banding and locking arrangement.Storage body is made of 18mm thick pre laminated partical Board conforming to IS : 12823 Interior Grade.The back of the unit is made from 18mm prelaminated board. All the exposed edges are with 2mm PVC egde Imported banding & sealed edges are with 0.8mm thick PVC Imported edge banding. The top, side and hinged shutters are sealed with 2mm thick PVC edge banding. Storage has adjustable shelves inside and cam lock, tower bolt and locking strips.The units are assembled by knock down fittings such as Minifix & Dowels. All the hardware and Hinges are from Hettich/Ebco. Storage has Brushed SS finish handles and lock . Prelam storage unit of 1200mm ht and 450mm depth .
Doc. Change room / Nurse Changr room
Locker:- 1800mm Ht x 375mm W x 450mm D
Add 18% GST
Add 1% Labour cess 1%
SHREE GAUTAM CONSTRUCTION COMPANY LIMITED
Bidder Name
SHREE GAUTAM CONSTRUCTION COMPANY LIMITED
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid