| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-AOC NO 26 GURU AMARDAS COLONY BHAINSA NAKA SAGAR MADHYA PRADESH 470001 | SAGAR | MADHYA PRADESH | 470001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹36.5 L+₹2.9 L (8.52%)Rejected-Finance SNEH NAGAR COLONY NEAR ABKARI OFFICE SHIVAJI WARD SAGAR MP 47000 | SAGAR | SAGAR | MP | 47000 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹41.7 L+₹8.1 L (24.1%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹44.5 L+₹10.8 L (32.2%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
10 Oct 2023, 6:00 pmClosed
GARRISON ENGINEER SAUGOR
Military Engineer services Garrison Engineer Saugor MP- 470001
REPAIR/ REPLACEMENT OF MISC E/M NATURE AND VARIOUS WATTAGE OF STREET LIGHT, FLOOD LIGHT, HIGH MST LIGHTS WITH CONNECTED WORKS UNDER GE SAUGOR.
2023_MES_617983_1
GE/SGR/TOK-43 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SAUGOR
Class D category b (i) and as per tender documents
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER SAGAR
₹1 L
Yes
14 Nov 2023
9 Sept 2023
12 Oct 2023
9 Sept 2023
10 Oct 2023
26 Sept 2023
11 Sept 2023 - 18 Sept 2023
Amount
S&F in replacement cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
S&F in replacement framed work as in doors or gates of angle made out of FE 410-W Gde E-250 quality -A or other section with gusset plates, rails, fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
M&L including fabrication of existing panel cover with hing, nut and bolt with two coat synthetic enamel painting complete all as specified and directed.
M&L in replacement for GI wire 4mm dia (8 SWG) stretching and fixing on pole for continious earth conductor, Guard wire 3.2 mm (10 SWG) for cradle (Hexagonal/rectangular) including binding wire round insulator ete complete all as specified and directed.
M&L for cutting of vegetation surrounding transformer, two poles, four pole structure at various sub station/ E&M installation and remove to a distance not exc 50 mtr complete all as specified and directed.
S&F in replacement galvanised iron pipe light grade ( ISI marked) with all fittings laid in trenches or on pole, crossing of road,fixed on wall for protection of cables complete all as specified and directed of 40mm bore complete all as specified and directed.
All as per Srl item No 6 above but 50mm bore
All as per Srl item No 6 above but 80mm bore
All as per Srl item No 6 above but 100mm bore
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregates) as in foundation of stay assy/ pole etc, including form work complete in all as specified and directed
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregates) for coping/plinth of poles, including necessary form work finished even & smooth without using extra cement all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm, 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm, 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm, 4 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sqmm, 2 core including taking down existing unserviceable cable and removing from site complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding1.5 meter wide and not exceeding 1.5 metre wide and not exceeding 1.5metre in depth and getting out complete all as specified and directed
Excavation in trenches in hard/dense soil not exceeding1.5 meter wide and not exceeding 1.5 metre wide and not exceeding 1.5metre in depth and getting out complete all as specified and directed
M&L for sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building complete all as specified and directed
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed.
Removing excavated materials (soil) not exceeding 50metre and depositing where directed at a level not exceeding 1.5 meter above starting point complete all as specified and directed
Returning filling in with excavated soil, including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Taking down and Re-laying/re-routing of LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of any size laid in trenches or fixed on wall/floor/polesincluding taking out old unserviceable/ serviceable bricks, cable covers, GI pipe of any size for reuse from trenches for removing all as specified and directed
S&F in replacement onload changeover switch (side handle) in sheet enclosure, 100 Amps, four pole, 415V, 50Hz with handle complete all as specified and directed
S&F in replacement HRC fuse 6 to 16 Amps as per existing to be fixed in HT panel complete all as specified and directed.
S&F in replacement in replacement battery 12V 7 AH maintenance free sealed lead acid battery for portable OT light complete all as specified and directed
S&F in replacement battery 12V 26 AH maintenance free sealed lead acid battery for 5 KVA online UPS complete all as specified and directed
S&F in replacement battery 12V 42 AH maintenance free sealed lead acid battery for portable OT light complete all as specified and directed
M&L for checking, cleaning and making functional in all respect of online UPS of any capacity including cleaning inside and outside complete all as specified and directed
S&F in replacement of IGBT suitable for 5KVA online UPS as per existing complete all as specified and directed.
S&F in replacement of SMPS suitable for 5KVA online UPS as per existing complete all as specified and directed.
S&F in replacement of Control card suitable for 5KVA online UPS as per existing complete all as specified and directed.
S&F in replacement of driver card suitable for 5KVA online UPS as per existing complete all as specified and directed.
S&F in replacement of EP ROM card card suitable for 5KVA online UPS as per existing complete all as specified and directed.
S&F in replacement of transformer OP sense suitable for 5KVA online UPS as per existing complete all as specified and directed.
S&F in replacement of capacitor suitable for 5KVA online UPS as per existing complete all as specified and directed.
M&L for checking of DC battery charger 30Volts of any size with minimum requirement of material all as per site requirement complete all as directed. (Note : Quoted rates shall be deemed to include opening of battery charger accessories and taking the defective items to the approved workshop)
M&L for checking of earth resistance of earthing pit at different location as indicated by Engr-in-Charge with the help of earth resistence testing kit including making proper record of test report and getting signature of user and Authoritries complete all as specifed and directed
M&L for checking of earth resistance of lightning conductor installed over various buildings, including checking of air termination rods, earth continuity GI/aluminium strip and rectifying minor defects complete all as specifed and directed
M&L for replacement of PVC/Porcelain saddle used for fixing of GI/Aluminium strip on wall/roof including screw, wall plug etc complete all as specified and directed.
S&F in replacement Air termination single pointed copper rod 12 mm dia 300mm long fixed on pole near gantry structure complete all as specified and directed.
S&F in replacement earth continuity conductor or main earthing lead fixed to wall & roof top in grid connection with air termination rod of size 25X 3mm aluminium strip including PVC saddles complete all as specified and directed.
M&L for earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25X4mm galvanised iron or steel wire complete all as specified and directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected to galvanized iron strip 25x4mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth strip protected by 40mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified & directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected to and including galvanised earth lead 4.0 mm dia as earthling lead by means of bolts, nuts, check-nuts, and washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified & directed by Engr-in-Charge.
S&F in replacement street light pole junction box factory made Triple Pole and neutral IP 65 thermoplastic PC-GFS polycarbonate oval shape, weather proof, rust free, dust free and corrosion free, with internal embedded polyureathin material gaskit, junction box should be flame retardant and self extinguish in accordance with IEC-60695-2-11, with multilevel knockouts for cable glands in different sizes. The junction box compression of optional cable entry in four side, 25 Sqmm terminal block - 04 Nos, MCB SP 10A with flap - 01 No, Disconnected type neutral terminal 6 Sqmm-01No and Earth terminal block 4 Sqmm - 01 No including mounting arrangement complete all as specfied and directed Make - Hensel cat./DRW No HENKFPJB-5 of equivalent make of same specification.
S&F in repairs of strandard aluminium conductor flat twin core PVC insulated unseathed 1100 volt 10 sqmm 2 core complete all as specified and directed.
S&F in repairs round flexible PVC insulated copper cable of size 1.5 sqmm 3 core, 1100 volt grading complete all as specified and directed.
S&F PVC conduit 20mm dia including fixing on wall/pole with necessary fixing arrangement complete all as specified and directed.
S&F in replacement of MS Chequered plate of 5 mm thick or over in thickness in available of Fe - 290 Gde E165 and fixed in substation building including painting with black colour over one coat of red oxide primeover and making provision for lifting the plate from duct complete all as specified and directed.
M&L for glow sign board for E/M installation with computerised words printed on PVC board (matter and size of letters as approved by Engr-in-Charge) including fabrication of work, angle iron, electrical connection with suitable copper wire and LED tube light fittings complete all as specified and directed.
S&F framed electrical safety wheather proof chart with latest procedure for giving first aid to electricuted victim complete all as specified and directed.
M&L for painting and writing with paint in all existing sign boards such as SM/MES No board of equipments and other board as per the direction given by Engr-in-Charge in E/M installation 33KV MRS, Berthuma and Chittora with skilled painter after applying two coat synthetic enamel paint over a primer, content, colour and letter size as approved by Engr-in-Charge complete all as specified and directed.
M&L for computerised print on PVC board with blue background and white letter of suitable size indicating incoming from, outgoing to the area of distribution, capacity and CT ratio fixed at the front side of each panel both HT and LT panel section wise complete including necessary fixing arragement in E/M installation/sub station (matter and size of letters as approved by Engr-in-Charge) complete all as specified and directed.
S&F in replacement LED bollard 15w and one meter height energy saving, environmental friendly, long life aesthetically designed aluminium landcape luminaire for diffused lighting with high power LED light source complete all as specified and directed
S&F in replacement LED bollard 8w and two feet height IP 65 as a imposing street furniture. The elegant yet minimalsitic design acts silent observer and giving light, diffuser at the upper protion acts a beacon of path guidance in a landscape environment complete all as specified and directed
S&F in replacement bay bright light energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium canopy fixture with high power LEDs as light source, suitable for lighting under canopy etc complete all as specfied and directed
S&F in replacement LED environmental friendly, new generation, energy saving, decorative rectangular shaped step light with IP protection minimum 7w for wall recessed application suitable for indentification of seats and steps inside the theatre/Auditorium complete model or design and wattage as approved by Engr-in-Charge/GE complete all as specified and as directed
M&L for painting of PCC pole (Cross arms, clamps etc) with 2 coats of aluminium paints and including preparation of surfaces and painting upto the height of 1.2 m pole 9 m long with 2 coats of synthetic enameled paint including preparation of old surfaces and making colour bands and rewriting the pole number complete all as specified and as directed
M&L for painting of tubular/ rail pole (Cross arms, clamps etc) with 2 coats of aluminium paints and including preparation of surfaces and painting upto the height upto 9 m pole with 2 coats of synthetic enameled paint including preparation of old surfaces and making colour bands and rewriting the pole number complete all as specified and as directed
Supply only bamboo/wooden ladder of height not less than 20 feet of good strength tobe used for external complaints of various nature complete all as specified and directed.
M&L for painting of steel srtuctures in MRS including all cross arms, clamps etc with 2 coats of aluminium paints and including preparation of surfaces and painting upto the height upto 9 m with 2 coats of synthetic enameled paint including preparation of old surfaces complete all as specified and as directed
S&F in replacement LT/HT cable route indicator round in shape of aluminium alloy fixed on suitable angle iron including necessary PCC of (1:3:6) type C-2 using 40mm graded stone aggregate for grouting the angle not less than one feet by one feet pit and painting the plate with colour as indicated by Engr-in-Charge complete all as specified and directed.
M & L for repairing and servicing two/four pole structures comprising of following works :- (a) Dismantling the ACSR jumper connection from Air break Gang operated drop out fuse end lightening arrestors etc from the two poles structures, replacing the complete jumpers in to new with ACSR conductors including connecting with suitable thimbles connections/binding/PG clamps and providing monoplast compound over binding/thimble connections b) Removing the complete rusted bolts, nuts and washers and replacing with new bolts, nuts and washers (c) Disconnecting the AB switch knives cleaning and servicing by lubricating the moving parts terminals with petroleum jelly. (d) Cleaning the exposed surfaces of two pole structure complete and painting with two coats of synthetic enamel aluminium paint all as specified and directed by Engr-in-Charge
Cutting /trimming of tree branches upto 80 mm girth along LT/HT OH electric lines which or growing /touching or falling on ACSR conductor /poles or near by sub stns etc at any height from GL and making sufficient clearance not less than 1.5 mtr from ACSR conductor/ poles/ structure and taking down the same on the ground carefully avoiding the damage of and removing to a distance including stretching of conductor as required where directed by Engr - in -charge. Note :- Tree cutting will be maintain for periodisity for three months depending upon the grougth of three branches.
Disconnecting/taking down and re-fixing fluorescent tube light/HPSV/MH/HPMV/LED street light of any wattage or size flood lights street light fittings for repair or replacement of worn out accessories from pole up to 11 mtr complete all as specified. (a) Spare parts/ Lamp shall be measured and paid for separately
Disconnecting and taking down High mast light up to 25 Mtr Height including taking down mast assy by making necessary arrangement viz telescoping ladder alongwith all safety arrangement and repositing of the same after repairing all as directed, Note:- Relevent items shall be meaured and paid separately.
S&F in repair MS flat iron clamps, nut bolt of existing size for bracket on pole complete all as directed.
S&F in repair galvanised iron tubing 40mm bore, light grade bent to shape of bracket 1.2 Mtr in length for mounting of street light fitting and fixed on pole with clamp and nut, bolt and washer with two coat paint complete all as directed.
Supply only constant current LED driver as per existing make suitable for flood light fitting 240/200 watt complete all as directed.
S&F constant current LED driver suitable for flood light fitting 150 watt complete all as directed.
Supply only constant current LED driver as per existing make suitable for street light fitting 90 watt complete all as directed.
Supply only constant current LED driver as per existing make suitable for street light fitting 72/80 watt complete all as directed.
Supply only constant current LED driver as per existing make suitable for street light fitting 90 watt complete all as directed.
Supply only constant current LED driver as per existing make suitable for street light fitting 72 watt complete all as directed.
Supply only constant current LED driver as per existing make suitable for street light fitting 90 watt complete all as directed.
Supply only constant current LED driver as per existing make suitable for street light fitting 72 watt complete all as directed.
Supply only constant current LED driver as per existing make suitable for street light fitting 90 watt complete all as directed.
Supply only constant current LED driver as per existing make suitable for street light fitting 90 watt complete all as directed.
Supply only constant current LED driver as per existing make suitable for street light fitting 60 watt complete all as directed.
Supply only LED panel as per existing make suitable for street light fitting 72/90 watt complete all as directed.
Supply only panel as per existing make suitable for street light fitting 72/90 watt complete all as directed.
Supply only LED panel as per existing make suitable for street light fitting 90 watt complete all as directed.
Supply only LED panel as per existing make suitable for street light fitting 60 watt complete all as directed.
Supply only LED panel as per existing make suitable for street light fitting 90 watt complete all as directed.
Supply only LED panel as per existing make suitable for flood light fitting 150 watt complete all as directed.
Supply only LED panel as per existing make suitable for flood light fitting 200/240 watt complete all as directed
Supply only SPD suitable street light/flood light of any wattage complete all as directed.
S&F in replacement of 150 watt LED flood light fittings having long life of high power LED with SMD LED exclusive innovative dia cast aluminium IP-66 built in IP-67 electronic driver with APFC, lower THD, open circuit protection, over voltage protection, surge protection up to 10KV with built in SPD & other safety as per IS-15885 part -2 ,Sec 13, IEC 60598-1 of operating voltage 140-270V avg life 50,000 hours complete manufacture prove all test certificate as per protection for minimum 2 years from manufacturing companies complete all as specified and directed.
S&F in replacement of 200 watt LED flood light fittings having long life of high power LED with SMD LED exclusive innovative dia cast aluminium IP-66 built in IP-67 electronic driver with APFC, lower THD, open circuit protection, over voltage protection, surge protection up to 10KV with built in SPD & other safety as per IS-15885 part -2 ,Sec 13, IEC 60598-1 of operating voltage 140-270V avg life 50,000 hours complete manufacture prove all test certificate as per protection for minimum 2 years from manufacturing companies complete all as specified and directed
S&F LED Street Light fixture with IP-66 protected die-cast aluminium housing and heat resistive toughened glass. LED shall be having LM-79 and LM-80 complied as per L-70 standard. LEDs should be tested for minimum 10,000 burning hours with 5700-6000 K CCT. Maximum power consumption shall not exceed 90W and system lumens shall not be less than 9,000. Optics shall be properly designed with Polycarbonate Lenses to avoid dark patches on the road. Street light without lenses will not be acceptable. Driver shall be 3 stage "Constant Current Constant Voltage" with voltage range of 150-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60 V DC. Note: (i) The item rate shall deem to include provision of weather proof PVC insulated aluminium conductor cable 2.5 Sqmm, 2 core as required. (ii) LEDs used in the product shall comply with EN-62471 for photo - biological safety and certificate for the same from manufacturer shall be provided. Luminaire manufacturer shall produce certificate of association with LED manufacturer for minimum two years. Make: Havells/Wipro/Halonix/Orient
S&F LED Street Light fixture with IP-66 protected die-cast aluminium housing and heat resistive toughened glass. LED shall be having LM-79 and LM-80 complied as per L-70 standard. Maximum power consumption shall not exceed 60W and system lumens shall not be less than 9,000. Optics shall be properly designed with Polycarbonate Lenses to avoid dark patches on the road. Street light without lenses will not be acceptable. Driver shall be 3 stage "Constant Current Constant Voltage" with voltage range of 150-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60 V DC. Note: (i) The item rate shall deem to include provision of weather proof PVC insulated aluminium conductor cable 2.5 Sqmm, 2 core as required. (ii) Contractor shall produce warrinty certificate of association with LED manufacturer for minimum two years.
S&F in replacement timer switch for street lights control for 3 KW Single Phase rating consists of the following items :- (a) Swadeep-02EC-3KW1P (b) contactor AC3 25 Amps - 01 No (c) Incoming MCB of 25 Amps - 01 No (d) Outgoing MCB of 25 Amps - 01 No (e) complete single phase circuit wiring
S&F in replacement time switch for street lights control for 5 KW three Phase rating consists of the following items :- (a) Swadeep-02EC-5KW3P (b) contactor AC3 16 Amps per phase - 03 No (c) Incoming MCB of 20 Amps - 01 No (d) Outgoing MCB of 20 Amps - 01 No (e) complete single phase circuit wiring
M&L in replacement for stranded aluminium conductor flat twin core PVC insulated unsheathed 1100V 10 Sqmm 2 core complete all as specified and directed.
M&L in replacement for stranded aluminium conductor flat twin core PVC insulated unsheathed 1100V 2.5 Sqmm 2 core complete all as specified and directed.
Supply, laying, connecting and testing in replacement cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 35 Sqmm 3.5core complete all as specified and directed.
All as per Srl item No 94 above but size 16 sqmm, 4 core complete all as specified and directed.
All as per Srl item No 94 above but size 10 sqmm, 4 core complete all as specified and directed.
All as per Srl item No 94 above but size 10 sqmm, 2 core complete all as specified and directed.
S&F in replacement junction box Triple Pole and neutral enclosure compression gland 2 with connector and clamp for pole mounting with two nos of nut bolt and washers and socket complete of size not less than 12"x10"x4" complete all as specified by Engineer -in- Charge Make - Sintex/Hensel
S&F in replacement junction box Single Pole and neutral enclosure compression gland 2 with connector and clamp for pole mounting with two nos of nut bolt and washers and socket complete of size not less than 12"x10"x4" complete all as specified by Engineer -in- Charge. Make - Sintex/Hensel
S&F in replacement analog time watch FM/1 quartz 16A 250AC suitable for high mast panel all as directed by Engr-in-Charge.
S&F in replacement auxiliary contactor MNX-A2 415V 10A suitable for high mast panel all as directed by Engr-in-Charge.
S&F in replacement lower raising push botton no NC auxiliary contactor MNX-A2 415V 10A suitable for high mast panel all as directed by Engr-in-Charge.
S&F in replacement one/two way connector suitable for high mast panel/street light connection all as directed
S&F in replacement flat cable flexible copper of size 2.5 sqmm 5 core, 1100 volt grading complete all as specified and directed by Engr-in-Charge
S&F in replacement flat cable flexible copper of size 1.5 sqmm 3 core, 1100 volt grading complete all as specified and directed by Engr-in-Charge
M&L in replacement of chain pully motor & greasing chain pully of high mast light complete all as specified and directed by Engr-in-Charge
S & F in replacement MCB single pole and neutral 40 to 63 Amp 240 Volts 'C' series 10 KA complete all as specified and directed
S & F in replacement MCB SP 6 to 40 Amps, 240V 'C' Series 10 KA complete all as specified and directed
S&F in replacement of lazer engraved chair row marker 12V, DC light as per site requirement to be fixed on chair as indicated by means of suitable screw complete all as specified and directed.
S&F in replacement of SMPS heavy duty industrial power supply 12V/10 Amp, input 230V, AC and out put 12V, DC complete to control the seat / chair complete all as specified and directed.
shubhanshu traders
shivansh traders
Goodluck Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .