Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | ₹12.9 L Quoted ₹15.9 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹21.1 L+₹5.2 L (32.5%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | ₹21.1 L+₹5.2 L (32.5%) | L2 | Rejected-Finance Other than L1 Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not Recommended due to not enlisted with required category |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not Recommended due to documents as required as per Para 1.5 of Manual of Contract not uploaded |
| 5 | Rejected-Technical H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | - | - | Rejected-Technical Not Recommended due to not enlisted with required category |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
16 Nov 2023, 6:00 pmClosed
Cdr, HQ 138
HQ 138 Works Engineers PIN-914138 C/O 56 APO
REPAIR / MAINT OF GEYSERS, DEEP FREEZERS, REFRIGARATORSAND ACs UNDER AGE E/M-II OF GE 865 EWS AT LEH
2023_MES_598254_3
138WE/L-30/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 865 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 865 EWS
₹50,000
Yes
21 Mar 2024
26 Oct 2023
23 Nov 2023
26 Oct 2023
16 Nov 2023
2 Nov 2023
Amount
Taking down water heater storage type cap 25 Ltr of any make Vertical/horizontal type after disconnecting the electric/ water connections and dismantling the heating elements /geyser assy and descaling complete with descaling solutions and replacement of gaskets suitable for resisting 98 degree temp /nut bolts etc, all as directed and testing the safety devices and reinstalling at same location complete all as specified and directed by Engr in Charge.
Taking down water heater storage type cap 50 Ltr of any make Vertical/horizontal type after disconnecting the electric/ water connections and dismantling the heating elements /geyser assy and descaling complete with de scaling solutions and replacement of gaskets suitable for resisting 98 degree temp /nut bolts etc all as directed and testing the safety devices and reinstalling at same location complete all as specified and directed by Engr-in-Charge.
S &F in replacement of water inlet/outlet assy suitable for storage water heater of 25/50 Ltrs capacity having provn of housing thermostate, heating element including providing rubber gaskets and holding nut bolts etc complete all as specified and directed by Engr-in-Charge.
S &F in replacement of thermostate switch for water storage heater suitable for Racold type 220/240V 50HzAC temperature range 32 - 88 degree centigde ISI marked complete all as specified and directed by Engr-in-Charge.
S &F in replacement of thermostate switch for water storage heater suitable for pearl / orison type 220/240V 50HzAC temperature range 32 - 88 degree centigde ISI marked complete all as specified and directed by Engr-in-Charge.
S&F in replacement of heating elements suitable for water storage heater vertical type RACOLD/ORISON/PEARL make 220/240 V AC 1500W and making connections and testing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of heating elements suitable for water storage heater vertical type RACOLD/ ORISON/PEARL make 220/240 V AC 2000W and making connections and testing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of heavy duty PVC connections 600 mm long armored type with brass union ,nut, heat resistance type rubber washer for hot water complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC connections 600 mm long with brass union ,nut, rubber washer for cold water complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Indicating lamps (Red and Green) suitable for storage water heater any type & cap complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC insulated and sheathed flexible cable 3 core with copper conductor of size 40/0.0076 complete all as specified and directed by Engr-in-Charge.
S&F in replacement of GI tubing 15 mm bore medium gde for geyser vent /water connections with required fittings complete fixed to wall /ceilings including making good the disturbed surfaces complete all as specified and directed by Engr-in-Charge.
S&F in replacement of GI tubing 20 mm bore medium grade for geyser vent /water connections with required fittings complete fixed to wall /ceilings including making good the disturbed surfaces complete all as specified and directed by Engr-in-Charge.
S&F Stop valve brass CP of size 15 mm dia heavy duty complete all as specified and directed by Engr-in-Charge.
S&F Angle valve brass CP of size 15 mm dia heavy duty complete all as specified and directed.
S&F Plug Top 15 Amps suitable for working on 230 volts 50 Hz AC supply complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 Pin 5 and 15 Amp flush type universal complete all as specified and directed.
S& replacement of old unsv gang box with 2 in 1, 3 pin 5 and 15 Amp flush type universal universal complete all as specified and directed.
S&F stainless steel tank of capacity 25 ltr as per sample complete all as specified and directed by Engr in Charge.
S&F stainless steel tank of capacity 50 ltr as per sample complete all as specified and directed by Engr in Charge.
Supply & fix new compressor 1/8 HP suitable for refrigerator of capacity 165 to 200 Ltr in replacement of burnt defective compressor. The work includes taking out the defective compressor and testing complete all as specified and directed by Engr-in-Charge. Note:- (a) (Charging of gas R-134 a shall be paid separetely under respective item).
All as per item No- 21 above but 1/6 HP but refrigerator capacity 220 to 320 Ltrs complete all as specified and directed by Engr-in-Charge.
S/F in replacement of evaporator cooling coil of refrigerant 165 to 200 ltrs capacity complete all as specified and directed by Engr-in-Charge.
S/F in replacement of evaporator cooling coil of refrigerant 220 to 320 ltrs capacitycomplete all as specified and directed by Engr-in-Charge.
S&F in replacement of relay box type/open type suitable for 1/6 to 1/8 HP refrigerator of any make & size complete all as specified and directed by Engr-in-Charge.
S/F in replacement of overload protector suitable for refrigerator of any make & size complete all as specified and directed by Engr-in-Charge.
Taking out burnt defective compressor 1/3 HP from deep freezer of cap 420/425/320 ltr & S/F new compressor 1/3 HP capacity suitable for deep freezers 425/320 ltrs capacity of make Kelvinator/Ashoka including dehydrating of system and charging of comp oil & refrigerant gas complete all as specified and directed by Engr in Charge.
S&F in replacement of thermostatic switch for refrigerator of any make and 165 to 320 Ltrs Capacity complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacment door gasket suitable for refrigerator of capacity 165/200 ltrs single door complete all as specified and directed by Engr-in-Charge..
Supply and fix in replacment door gasket suitable for refrigerator of capacity 286/300 ltrs single door complete all as specified and directed by Engr-in-Charge..
Supply and charging the refrigerent gas R-134a in refrigerators of capacity 165 to 200 litrs including testing complete all as specified and directed by Engr-in-Charge.
Supply and charging the refrigerent gas R-134a in refrigerators of capacity 200 to 320 litrs including testing complete all as specified and directed by Engr-in-Charge.
Supply and charging the refrigerent gas R-134a in deepfreezers of capacity 200 to 425 litrs including testing complete all as specified and directed by Engr-in-Charge.
M&L for Servicing of split type AC 1.5/2 TR capacity including oiling greasing of fan motor replacement of synthetic filter & checking of electric circuit for smooth functioning of AC (S&F of unserviceable burnt spare parts of machine shall be measured and paid for separately under respective items) complete all as specified and directed by Engr-in-Charge.
S&F in replacement of capacitor 45+6 mfd suitable for 1.5 capacity AC complete all as specified and directed by Engr-in-Charge.
All as per above Item No- 35 but 50+6 Mfd suitable for 2.0 Ton capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement of wiring kit suitable for 1.5/2 ton capacity split AC complete all as specified and directed by Engr-in-Charge.
S&F in replacement of metal clad socket 20 Amp complete all as specified and directed by Engr in Charge.
S&F in replacement of Metal clad plug complete all as specified and directed by Engr in Charge.
Taking out unserviceable fan/blower motor and M&L for rewinding and repairing of fan motor of split type AC 1.5/2.00 TR capacity with supper enameled copper winding wire of existing gauge complete all as specified and directed by Engr-in-Charge.
S&F New rotary type compressor suitable for split type AC of capacity 1.5 TR in replacement to unserviceable compressor complete all as specified and directed by Engr-in-Charge. (Charging of gas shall be paid separately under respective item)
All as per above item No- 41 but capacity 2.0 TR complete all as specified and directed by Engr-in-Charge. .
S&F New Fan blade for 1.5/2 TR Split AC in replacement of old underviceable fan blade complete all as specified and directed by Engr-in-Charge.
S&F New blower for 1.5/2 TR split AC in replacement of old underviceable blower complete all as specified and directed by Engr-in-Charge.
Supply & charging the refrigerant gas R-134a to window/ split type AC upto 2 Ton capacity including testing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB SP 20 to 32 Amps Cap 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB SPN 40 Amps Cap 230 volt AC supply complete all as specified and directed by Engr in Charge.
S&F in replacement of MCB SPN 63 Amps Cap 230 volt AC supply complete all as specified and directed by Engr in Charge.
Supply and fix sheet metal single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps complete all as specified and directed by Engr-in-Charge.
S&F condensor with copper tubing and aluminium fins suitable for 1.5/2.0 TR split AC in replacement of old underviceable condenser complete all as specified and directed by Engr-in-Charge..
Supply and fix in replacement new PCB card suitable for 1.5/2TR capacity of split AC's complete all as specified and directed by Engr-in-Charge.
Supply and fix in repalcement new swing motor suitable for 1.5/2 TR capacity of window/split AC complete all as specified and directed by Engr-in-Charge.
Supply and fix in repalcement of PVC drain pipe 15 mm dia with fittings and fixing accessories complete all as specified and directed by Engr-in-Charge.
Labour only to convert split AC 1.5/2.0 TR from cooling mode to heating mode by heating element/ reverse solenoid valve arrangement wiring interlocking as required complete all as specified and as directed by Engineer-in-charge.
S&F reverse valve suitable for split type AC 1.5/2.0 TR incuding additional copper tubing of any size brazing work, pressure testing, dehydration gas charging upto required level and necessary modification in remote control unit for satisfactory function of unit in heating mode complete all as specified and directed by Engineer in charge.
Supply and replacement electric cable PVC insulated rubber sheathed circular multistranded copper conductor of size 2.5 Sqmm 3 Core complete all as specified and directed by Engr-in-Charge.
Rewinding of burnt windings of Ex : fans of size 400-450 mm size including dismantling from loc and removing the burnt out winding , cleaning the stator with CTC solution to remove the burnt slots. Rewinding the same with new super enamelled copper wire same gauge and size /number of turns , varnishing the winding completely and reassembling complete all as specified and directed by Engr-in-Charge. (Spare parts replaced will be measured &paid seperately)
Al as per above item No 57 above but exhaust fan of size up to 300 mm sweep complete all as specified and directed by Engr-in-Charge.
M&L replacement of louvers made out of metal sheets suitable for up to 450 mm sweep exhaust fans complete all as specified and directed by Engr-in-Charge.
supply and fix Flexible twin twisted copper wire two core of size 23/0.0076mm upto 1.5 mtr length complete all as specified and directed by Engr-in-Charge.
supply and fix Ball bearing suitable for Exhaust fan 400mm - 450mm sweep any make complete all as specified and directed by Engr-in-Charge.
Supply and fix Ball bearing suitable for Exhaust fan up to 300 mm sweep any make complete all as specified and directed by Engr-in-Charge.
Supply and fix Condensor 2.5 MFD 230 V suitable for Exhaust fan of any sweep/size complete all as specified and directed by Engr-in-Charge.
Condensor 4 MFD 230 V suitable for Exhaust fan of any sweep/size complete all as specified and directed by Engr-in-Charge.
Supply and fix Gun metal Bushings suitable for Exhaust fan fan up to 300 mm sweep any make complete all as specified and directed by Engr-in-Charge.
Supply and fix Gun metal Bushings suitable for Exhaust fan up to 450mm mm sweep any make complete all as specified and directed by Engr-in-Charge.
Supply and fixing strorage type water heaters, vertical type, 25 Ltrs capacity with Energy saving Incology 800 heating element, Feroglass coated tank with single weld line design, high density PUF insulation with power 2000 watts, operating voltage 220-240 volts, with superior heating performance and excellent resistance to both oxidation & carbonisation at high temp setting including of wall manual accessory and 2 flexi hot and cold water pipe complete all as specified and directed by Engr-in-Charge.
Supply and fixing strorage type water heaters, vertical type, 50 Ltrs capacity with Energy saving Incology 800 heating element, Feroglass coated tank with single weld line design, high density PUF insulation with power 2000 watts, operating voltage 220-240 volts, with superior heating performance and excellent resistance to both oxidation & carbonisation at high temp setting including of wall manual accessory and 2 flexi hot and cold water pipe complete all as specified and directed by Engr-in-Charge.
SUMEET TRADING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .