Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-AOC M H HOUSE M H HOUSE CHAKUDIA MAHADEV ROAD RAKHIAL AHMEDABAD GUJARAT 380023 | AHMADABAD | GUJARAT | 380023 | ₹1.1 L | L1 | Accepted-AOC L1 FOR SOME ITEMS |
| 2 | L1₹2.4 CrAccepted-AOC LEADSLIP COMPOUND STAR ENGINEERS NEAR BHARAT BOBBINS OPPOSITE SHAMS SCHOOL RAKHIAL AHMEDABAD | ₹2.4 Cr | L1 | Accepted-AOC L1 FOR SOME ITEMS |
| 3 | L1₹3.3 CrAccepted-AOC LIBRA ENGINEERING WORKS 16 B ARCHNA INDUSTRIAL ESTATE OPP AJIT MILLS RAKHIAL AHMEDABAD GUJARAT 380023 | AHMADABAD | GUJARAT | 380023 | ₹3.3 Cr | L1 | Accepted-AOC L1 FOR SOME ITEMS |
| 4 | Rejected-Technical 218 BAKROL BUJARANG OPP N K INDUSTRIAL PARK DHAMATVAN ROAD BAKROL AHMEDABAD GUJARAT 382210 | AHMADABAD | GUJARAT | 382210 | - | - | Rejected-Technical Bidder is not meeting tender commercial experience criteria |
| 5 | Rejected-Technical C1 356 ODHAV GIDC ROAD NO 38 OPP HOUSING COLONY ODHAV ODHAV GIDC AHMEDABAD GUJARAT 382415 | AHMADABAD | GUJARAT | 382415 | - | - | Rejected-Technical Submitted PO values are not qualifying minimum order value required for three executed orders as per commercial experience criteria. Bidder is not meeting tender commercial experience criteria. |
Tender Value
Refer Docs
Closing Date
8 Apr 2021, 3:00 pmClosed
DGM MATERIALS
IOCL HALDIA REFINERY
Two Years ARC for procurement of Valves
2021_HR_133258_1
RHM20R4023
Open Tender
Mechanical - All
Supply
120 days
IOCL HALDIA REFINERY
AS PER TENDER DOCUMENT
6 documents required · 6 mandatory
Exempted
26 Oct 2021
25 Mar 2021
9 Apr 2021
25 Mar 2021
8 Apr 2021
25 Mar 2021
Amount
Laying and Jointing PVC Pipe. Heading
VLV.GLB.FL.RF, SS A351 CF8,SS304 3IN,150 AS PER IOCL TENDER TECHNICAL SPECIFICATION
GL.VLV, A 351, GR.CF8C,FLGD,300,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A351,CF8C,SS321,FL,2IN,600 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV.GLB.FL.RF SS A351 CF8C,SS321 2IN 300 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GL,A351CF8C,SS321+STL,FLG,300,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A351CF3M,SS316L,FL,150,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANG,A351CF3M,SS316L,FLG,150,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,DISC,A217WC6,FL,600,10IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV GLOBE,A217WC6,BW,TRIM 5,3IN,900,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,A182F6,FLG,300,8IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,A182F6,FLG,300,6IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,A182F6,FLG,150,6IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,A182F6,FLG,300,4IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,A182F6,FLG,150,4IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,A182F6,FLG,600,3IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,A182F6,FLG,300,3IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,A182F6,FLG,600,2IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,A182F6,FLG,300,2IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,A182F6,FLG,150,2IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A182F9,A182F9,FLG,300,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,13% CR,FLG,150,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,13% CR,FLG,300,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A217C5,13%Cr,FLG,300,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VALVE,GLOBE,B/W,A217-WC6,4IN,900,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,A182F6,FLG,150,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,A182F6,FLG,300,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,A182F6,FLG,300,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,A182F6,FLG,150,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,FLG,300,12IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,FL,150,10IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,FLG,300,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,FLG,150,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,FLG,300,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,FLG,150,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,FL,600,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,FLG,300,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,FLG,150,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,FL,600,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,FL,300,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,FLG,150,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV.GLB,A216WCB,316L,NACE,6IN,300 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLOBE,RF,WEDGE, A216,150, 4IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,SS316L,FLG,300,3IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,SS316L,FLG,150,3IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,SS316L,FLG,300,2IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A216WCB,SS316L,FLG,150,2IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A217 WC6,13%Cr,FLG,600,8IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,A217 WC6,13%CR,FL,600,3IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216,CR13%,FL,300,12IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,300,6IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,300,4IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,150,4IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,300,3IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,600,2IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,13%Cr,300,2IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLB GLB, A-216 WCB, TRIM-8, FE, 150, 2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV GLB A352LCB A182F304 FLRF300 2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,SS316L,FL,150,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GLB,ANGLE,A216WCB,SS304,FL,150,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV GATE RF NB:12 IN A351 CF-8C, 600 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A351 CF8C,SS321,FLG,150,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A351 CF8C,SS321,FLG,300,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A351 CF8C,SS321,FLG,150,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A351CF8C,SS321,FLG,600,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A351 CF8C,SS321,FLG,300,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A351 CF8C,SS321,FLG,150,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A351 CF8,SS304,FLG,150,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A351CF8M,A351CF8M,FLG,300,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A351CF8M,A351CF8M,FLG,300,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A351CF8M,A351CF8M,FLG,600,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A351CF8M,A351CF8M,FLG,600,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A351CF8M,A351CF8M,FLG,300,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
GATE VL RF A351 CF8 600 2 IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A351 CF3M,SS316L,FL,150,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A351 CF3M,SS316L,FLG,150,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A351 CF3M,SS316L,FLG,150,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
GATE VALVE. A-351 CF3M 4IN,150 AS PER IOCL TENDER TECHNICAL SPECIFICATION
GATE VALVE. A-351 CF3M,3IN,150 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDG,A216WCB,13%Cr,FL,300,20IN,IB AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDG,A216WCB,13%Cr,FL,150,14IN,IB AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDG,A216WCB,13CR,FL,300,10IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%CR,FL,300,8IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FL,150,8IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FL,600,6IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FL,300,6IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%CR,FL,150,6IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FL,600,4IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FL,300,4IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FL,150,4IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FL,600,3IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FL,300,3IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FL,150,3IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FL,600,2IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FL,300,2IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FL,150,2IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217WC6,A217WC6,FLG,600,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C12,13%Cr,FLG,300,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C5,A217C5,FLG,300,10IN[ AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C5,A217C5,FLG,300,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C5,A217C5,FLG,300,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C5,A217C5,FL,300,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C5,A217C5,FLG,300,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C5,A217C5,FLG,300,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C5,A182F6,FLG,300,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C5,A182F6,FLG,300,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C5,A182F6,FLG,300,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C5,A182F6,FLG,150,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,150,24IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,150,20IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,150,18IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,300,16IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,150,16IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,300,14IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,150,14IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,300,12IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,150,12IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FL,300,10IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,150,10IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FL,300,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,150,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,300,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,150,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,600,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,300,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE, A216 WCB,13%Cr,FLG,150,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,600,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,300,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,150,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FL,600,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,300,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216 WCB,13%Cr,FLG,150,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216WCB,13%CR,RF,150,6IN,H2 AS PER IOCL TENDER TECHNICAL SPECIFICATION
GT,REGU,FLNG,CS,A216WCB,13%CR,6IN,150,H2 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FLG,300,4IN,H2 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FLG,150,4IN,H2 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FLG,300,3IN,H2 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FLG,150,3IN,H2 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216WCB,13%Cr,FL,600,2IN,H2 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A216WCB,13%Cr,FLG,300,2IN,H2 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216WCB,13%Cr,FL,150,2IN,H2 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GATE,A216 WCB,150,10IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,SS316L,FLG,300,8IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,SS316L,FLG,150,8IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,SS316L,FLG,300,6IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,SS316L,FLG,150,6IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,SS316L,FLG,300,4IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,SS316L,FLG,150,4IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,SS316L,FLG,300,3IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,SS316L,FLG,150,3IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,SS316L,FLG,300,2IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,SS316L,FLG,150,2IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A217 WC6,13%Cr,FLG,600,4IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A217 WC6,13%Cr,FLG,600,2IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A217 WC6,A182 F6,BW,900,2IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A217 WC6,A217WC6,BW,900,10 IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,A182 F6,FL,300,16IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,A182 F6,FLG,150,6IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,A182 F6,FLG,300,4IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,A182 F6,FLG,600,3IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VL GT A216WCBA182F6 FLG RTJ600 2IN IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A216 WCB,A182 F6,FLG,300,2IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A217,WC6,13%CR,STL,FL,600,2,H2 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GATE,A217 C6,CR13%,FL,600,3IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV GTHO.AS2"RF600A217WC6/13CR(IBR) AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT.A217 WC6 13% CR FLG 300, 20IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGEA217 WC6,13%Cr,FLG,600,10IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A217 WC6,13%Cr,FLG,300,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A217 WC6,13%Cr,FLG,300,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 WC6,13%Cr,FL,300,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C12,A217C12,FLG,300,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 C5,13%CR,FLG,150,10IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 C5,13%Cr,FLG,300,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 C5,13%Cr,FLG,300,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 C5,13%Cr,FL,150,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 C5,13%Cr,FLG,300,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 C5,13%Cr,FLG,150,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 C5,13%Cr,FLG,300,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 C5,13%Cr,FLG,150,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 C5,13%Cr,FLG,300,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 C5,13%Cr,FL,150,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WDGE,A352 LCB,A182F304,FL,150,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216WCB,SS316L,FLG,150,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216WCB,SS316L,FL,150,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216WCB,SS304,FL,150,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216WCB,SS304,FL,150,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216WCB,SS304,FL,150,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216WCB,SS304,FL,300,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A216WCB,SS304,FL,150,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV CHK A216WCB13%CR FLG RF 600 8IN IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,A216WCB,13%CR,FL,600,6IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV.CHK.SWIG.FL A216WCB 13%CR 3IN 600IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,A216WCB,13%CR,FL,600,2IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV CHK SWING A216 316L FL 300 3IN NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,A216WCB,316L,SW,150,3IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV CHK SWING A216 316L FL 300 2IN NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VL,CH,SW,A216,WCB,SS316,FL,150,2IN,NACE AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,A217 WC6,A182 F6,FLG,600,2IN,H2 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,A216WCB,A216WCB,FLG,300,4IN,IBR AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,A216 WCB,A182 F304,FLG,150,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,A216,WCB,316L,FL300,2IN,NAC+HIC AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,A216 WCB,316L,FL150,2IN,NACE+HIC AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWNG,A216WCB,SS316L,FLG,150,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWNG,A216WCB,SS316L,FLG,150,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A217C5,A217C5,FLG,300,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A217C5,A217C5,FLG,300,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A217C5,A217C5,FLG,300,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A217C5,A217C5,FLG,300,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,150,24IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,150,20IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%CR,FLG,150,16IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,300,14IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%CR,FLG,150,14IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,150,12IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,150,10IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,300,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,150,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,300,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,150,6IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV.CHK.SWG.FL.A216WCB,13%CR 4IN 600 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,300,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,150,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,300,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,150,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,300,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,CHK,SWING,A216WCB,13%Cr,FLG,150,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLVCHK,SWING,A216WCB13%CR,FL, 600,3IN,H2 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A351 CF8M,A182 F304L,FLG,150,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A351 CF8C,SS321,FL,300,12 AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A351CF3M,A182 F316L,FLG,150,12IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,A351 CF3M,A182 F316L,FLG,150,10IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 C5,13%CR,FLG,150,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 C5,13%Cr,FLG,300,10IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 C5,13%Cr,FLG,300,12IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217 C5,13%CR,FLG,150,12IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C12,13%CR,FLG,150,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C12,13%Cr,FLG,300,2IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C12,13%CR,FLG,150,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C12,13%Cr,FLG,300,3IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C12,13%CR,FLG,150,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C12,13%Cr,FLG,300,4IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C12,13%CR,FLG,150,8IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C12,13%CR,FLG,300,10IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C12,13%CR,FLG,150,12IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
VLV,GT,WEDGE,A217C12,13%Cr,FLG,300,12IN AS PER IOCL TENDER TECHNICAL SPECIFICATION
LIBRA ENGINEERING WORKS
M H VALVES PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .