Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹724.28Accepted-AOC | ₹724.28 | 1 | Accepted-AOC AS PER SAMITI |
| 2 | Not Admitted-Finance AHMEDNAGAR AHMEDNAGAR MAHARASHTRA 414111 | AHMEDNAGAR | MAHARASHTRA | 414111 | - | - | Not Admitted-Finance Not qualified for AOC |
| 3 | Not Admitted-Fee/PreQual/Technical 22 C SECTOR A SANWER ROAD INDORE MADHYA PRADESH 452015 | INDORE | MADHYA PRADESH | 452015 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical 116 TILAK NAGAR INDORE 452001 M P | INDORE | MADHYA PRADESH | 452001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | SATINDER SINGH HORA |
|---|---|---|---|---|
| 1.00 | GALAVANIZED STEEL CHAIN LINK FENCE FEBRIC – Mesh Size 100x100 mm(4 inchx4 inch) 3.15 mm mesh wire (115 WG) Dia wire approx weight per SQM 2.26 KG, Height 150 mm, Two number of line wire of 4 mm Dia, WIDTH CONFORMING TO IS 2721-2003 With Up to Date AMENDMENTS | 1 | वर्ग मीटर | 84.9 ₹100.18 Lowest |
| 2.00 | GALAVANIZED STEEL BARBED WIRE Type A-1 The barbs shall have Four points and shall be formed by twisting two point wires each two turns,tithly around Both the line wire making all together four complete turns line wire 2.5 mm,point wire 2.5 mm distance between two barbs 75 mm,conforming to IS 278-2009 | 1 | किग्रा | 67.4 ₹79.53 Lowest |
| 3.00 | RCC Fencing Poles Height 2.0 m
Type-Straight
Length - 2.00 m
Dimensions - Bottom 10x10 cm square, Top 8x8 cm square Cement Concrete Mix Cement, sand and metal ratio 1:2:4 with 12.5 nominal size coarse aggregate. Sand used should be free from clay and salt. concrete mix shall be conforming to grade M-15 of IS:456:2000 Certificate Compulsory
Reinforcement - 4 round vertical bars of 6 mm diameter. 11 no of stirrups of 6 mm diameter round MS bars 20 cm centre to centre
Hooks - 5 no, bottom hook should be provided 60 cm above the bottom of the pole, second at 82.5 cm, third hook at 112.5cm, fourth hook at 150 cm, top and fifth hook at 195 cm from bottom.
Manufacturing - In order to ensure desired compressive strength, RCC fencing poles should be compacted with the help of platform vibrators. Surface should be uniform andfree from voids. The concrete cover over the reinforcement should not be less than 1.5 cm. | 1 | नग | 198 ₹233.64 Lowest |
| 4.00 | GALAVANIZED STEEL CHAIN LINK FENCE FEBRIC – Mesh Size 75x75DIA Dia 4.00 MM MES Wire And 4.50 MM DIA LINE WIRE MM wire approx weight per SQM 2.26 KG, Height 150 mm, 2 NOS. UPTO 2MTR.Width And 3 NOS.Above 2 MTR.WIDTH CONFORMING TO TO IS 2721-2003 With Up to Date AMENDMENTS | 1 | वर्ग मीटर | 113.5 ₹133.93 Lowest |
| 5.00 | सागौन/यूकेलिप्टस/नीलगिरी पोल्स ( 2 मीटर लंबे पूर्ण रूप से सूखे, लकडी के खंबे जिस पर वाटर रेसिसटेन्ट पेन्ट किया हुआ) ( पोल्स साईज - मध्यम भाग 31 से 40 सेमी गोलाई एवं उपर के सिरे पर नुकीला होना चाहिये) | 1 | नग | 230 ₹271.4 Lowest |
| 6.00 | GI Wire | 1 | किग्रा | 75 ₹88.5 Lowest |
| 7.00 | Binding Wire | 1 | किग्रा | 75 ₹88.5 Lowest |
Tender Value
Refer Docs
EMD Value
₹3 L
Closing Date
7 Jun 2025, 12:00 pmClosed
DFO SOUTH SAGAR
Tili Road Sagar MP
Fencing Item
2025_MPFD_425953_1
118
Open Tender
Civil Construction Goods
Item Rate
All Ranges in South Sagar Division
As Per Tender (Sample Required)
2 documents required · 2 mandatory
₹5,000
₹3 L
18 Aug 2025
24 May 2025
9 Jun 2025
24 May 2025
7 Jun 2025
24 May 2025
GALAVANIZED STEEL CHAIN LINK FENCE FEBRIC – Mesh Size 100x100 mm(4 inchx4 inch) 3.15 mm mesh wire (115 WG) Dia wire approx weight per SQM 2.26 KG, Height 150 mm, Two number of line wire of 4 mm Dia, WIDTH CONFORMING TO IS 2721-2003 With Up to Date AMENDMENTS
GALAVANIZED STEEL BARBED WIRE Type A-1 The barbs shall have Four points and shall be formed by twisting two point wires each two turns,tithly around Both the line wire making all together four complete turns line wire 2.5 mm,point wire 2.5 mm distance between two barbs 75 mm,conforming to IS 278-2009
RCC Fencing Poles Height 2.0 m Type-Straight Length - 2.00 m Dimensions - Bottom 10x10 cm square, Top 8x8 cm square Cement Concrete Mix Cement, sand and metal ratio 1:2:4 with 12.5 nominal size coarse aggregate. Sand used should be free from clay and salt. concrete mix shall be conforming to grade M-15 of IS:456:2000 Certificate Compulsory Reinforcement - 4 round vertical bars of 6 mm diameter. 11 no of stirrups of 6 mm diameter round MS bars 20 cm centre to centre Hooks - 5 no, bottom hook should be provided 60 cm above the bottom of the pole, second at 82.5 cm, third hook at 112.5cm, fourth hook at 150 cm, top and fifth hook at 195 cm from bottom. Manufacturing - In order to ensure desired compressive strength, RCC fencing poles should be compacted with the help of platform vibrators. Surface should be uniform andfree from voids. The concrete cover over the reinforcement should not be less than 1.5 cm.
GALAVANIZED STEEL CHAIN LINK FENCE FEBRIC – Mesh Size 75x75DIA Dia 4.00 MM MES Wire And 4.50 MM DIA LINE WIRE MM wire approx weight per SQM 2.26 KG, Height 150 mm, 2 NOS. UPTO 2MTR.Width And 3 NOS.Above 2 MTR.WIDTH CONFORMING TO TO IS 2721-2003 With Up to Date AMENDMENTS
सागौन/यूकेलिप्टस/नीलगिरी पोल्स ( 2 मीटर लंबे पूर्ण रूप से सूखे, लकडी के खंबे जिस पर वाटर रेसिसटेन्ट पेन्ट किया हुआ) ( पोल्स साईज - मध्यम भाग 31 से 40 सेमी गोलाई एवं उपर के सिरे पर नुकीला होना चाहिये)
GI Wire
Binding Wire
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .