Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹14.4 LAccepted-AOC 569 SECTOR 20A CHANDIGARH | CHANDIGARH | CHANDIGARH | CHANDIGARH | ₹14.4 L | l1 | Accepted-AOC in order |
| 2 | l2₹14.7 LRejected-Finance 230 SECTOR 12 PANCHKULA | PANCHKULA | ₹14.7 L | l2 | Rejected-Finance not in order |
| 3 | l3₹15.4 LRejected-Finance | ₹15.4 L | l3 | Rejected-Finance not in order |
| 4 | l4₹15.5 LRejected-Finance 2177 SECTOR 21 C CHANDIGARH | ₹15.5 L | l4 | Rejected-Finance not in order |
Tender Value
₹15.9 L
EMD Value
₹31,720
Closing Date
11 Feb 2026, 12:00 pmClosed
Executive Engineer Roads Division No 1 MC Chd
Executive Engineer Roads Division No 1 MC Chd
Dismantling of Existing Kitchen and Construction of New Kitchen In Community Centre, Sector 38 (West) Chandigarh. Compliance Of Honable High Court Orders In COCP No.838 Of 2021 (OandM).
2026_MCC_90108_2
MCC/R1/2026/018
Open Tender
Civil Works
90 days
work
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹31,720
24 Mar 2026
4 Feb 2026
11 Feb 2026
4 Feb 2026
11 Feb 2026
4 Feb 2026
CIVIL WORK
Dismantling existing corrugated G.I. sheet complete in all respect and to the entire satisfaction of engineer-in-charge
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50metres lead. (DSR 15.18)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar (DSR:15.7.4)
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. (DSR 15.25)
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer in charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)(DSR : 15.2.2)
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm (DSR: 15.23.1)
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below (DSR 15.12.1)
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. (DSR 15.57)
Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead :Thickness above 25 mm up to 40 mm DSR 15.39.3
Dismantling old plaster or skirting raking out joints. (DSR 15.56)
Carriage of material (1.1) By Mechanical Transport including loading unloading and stacking complete in all respect using appropriate labour and machinery to carry and dispose the building rubbish/malba/dismatled and wastes to the Municipal Corporation C&D waste processing plant to an average lead of 14km and all lifts to entire satisfaction of Engineer in charge (1.1.2)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (DSR 2.8.1)
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level: ( 1 Cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size).DSR 4.1.10
Providing and laying Polished Granite stone flooring in required design and pattern in linear as well as curviliner portions of the building all complete as per the satisfaction of E.E. with 18mm thick stone slab over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointed with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer in charge : Polished Granite stone Slab jet black, Cherry Red, Elite Brown, Cat Eye or equivalent (DSR 8.13.1)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.1.1
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources (DSR 4.10)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.4.1)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)(DSR : 6.13.2)
12 mm cement plaster of mix :1 :4 (1 cement : 4 fine sand) 13.1.1)
Providing and fixing 1st quality ceramic glazed wall tile confirming to IS: 15622 (thicness to be specified by the manufacture of approved make in all colours shade except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, riswrs of steps and dados over 12mm thick bed of cement mortar 1:3 (: 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including painting in white cement mixad with pigment of matching shade complete in all respect to the entire satisfaction of the Enginner-In-Charge.(DSR : 8.31)
Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ) (DSR 5.9.4)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.3)
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Cold twisted bars (DSR5.22.3)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete DSR 13.26
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement prime (DSR 13.41.1)
WOODEN GROOVED ACOUSTICAL SLATS:- Providing and fixing wood based panels with lineal perforations of approved make dexune/armstrong and anutone as approved by Engineer-in-charge. The panels shall be Non FR grade with melamine laminate panels 2440mmx128mmx16mm with 2mm slats at 15mm pitch, Toungue and Groove edges for seamless mounting. The back of the panels fixed with acoustical fleece for sound Absorption panel is to be fixed on frame work with screw fixed horizontal or vertical to wall at every 600mm with centre & edge bracket in tongue & groove system on framework. The cavity of framework should be inserted with rock wool with 48 Kg density and 25mm thickness and alongwith all accessories complete in all respect and to the entire satisfaction of Engineer in charge.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sectins, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms /sqm (both sie inclusive) as per IS: 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm dia x50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hagers of 25x10x0.50mm of required length with nuts & bolts of required size and other and end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. wire at every junciton, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the permeter of ceiling fixed to wall/partition with the help of ral plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channels 0.5 mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230mm interval including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall upered and square edges of the board with recommended jointing compound jointing tapes finishing with jointing compound in 3 layers convering upto 150mm on both sides of joint and two coats of primer with putty suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with :12.5mm thick tapered edge gypsum plain board conforming to IS:-2095-Part-I
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer M.S. tube (DSR 10.26.1)
Credit of dismantled steel
Credit of brick
PUBLIC HEALTH WORK
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require.White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps For kitchen
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 For kitchen
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia For kitchen
Providing and fixing of ball cock of 20 mm complete in all respect as per the entire satisfaction of Engineer in Charge For kitchen
Providing and fixing brass bib cock of approved quality 15 mm nominal bore For kitchen
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore For kitchen
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backingRectangular shape 453x357 mm For kitchen
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gm s 15 mm nominal bore For kitchen
Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729
Providing and fixing soil, waste and vent pipes : 75 mm diameter Sand cast iron S&S pipe as per IS: 1729
Providing and fixing collar : 100 mm Sand cast iron S&S as per IS - 1729
75 mm diameter Sand cast iron S&S as per IS - 1729
Providing Drip Seal Joints to sand cast iron/centrifugally cast (spun) iron pipes & fittings of dia 100mm
Providing and fixing plain bend of required degree 100 mm dia Sand cast iron S&S as per IS - 1729 75 mm diameter
Sand cast iron S&S as per IS - 1729
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms For kitchen
Providing and fixing brass grating of approved quality and colour Circular type:100 mm nominal dia For kitchen
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : For kitchen
15 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall 20 mm dia nominal bore
Providing and fixing of C.P. Steel Grating Heavy (with hole without hole) size 4" i/d (Viking make)
Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) brick
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc.
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design. Inside dimensions 455x610 mm and 45 cm deep for single pipe line
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing of CP extension of size 15 mm. Heavy Duty complete in all respect
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 470x420 mm bowl depth 178 mm
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1:5 m in width or 10sqm or plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 100m.All kinds of soil For Flooring for Grease Chamber For Road gully For Chamber For 200mm SW pipe
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete 200 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design 200 mm diameter
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering – All work upto plinth level 1:5:10 (1cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size ) For Flooring For Road gully For Chamber
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering – All work upto plinth level.1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) For Chamber For Road gully
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) For Chamber Inside Chamber baffle wall For Road gully Outside Flooring
12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1cement: 4 fine sand) For Chamber Inside Chamber baffle wall Outside Flooring
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering , finishing and reinforcement with 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). For Flooring Outside walls
Providing and Fixing of precast RCC M-20 HD Road Gully cover and frames in 1:2 Cement Sand Mortar on the top of brick masonary chamber complete in all respects to the entire satisfaction of EIC.(Size of cover 690 x 537 x 80mm and of frame is 810 x 657 x 130mm). The work also includes removal/ dismantling of old frame and cover including minor repairs of the road gully if required. (1x4)=4
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placingin position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Making connection of drain or storm line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete For pipes 100 to 250 mm diameter
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. As per quantity No 26
Carriage of material by mechanical transport including loading, unloading and stacking As per quantity No 26
ELECTRICAL WORK
Dismantling and re-erection of Split Type Air Conditioners (in all respect including requriement of copper pipe/ drain pipe, etc.) at suitable height. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
Providing and fixing of 28 gauge copper piping for split/window AC 1/1.5/2 for between indoor & outdoor unit complete with sleeve type Kini insulation including the cost of chasing of brick wall, RCC & repairing the same in good conditions as per site requirement to the size & design of manufacture size of copper pipe 1/2"x1/4" with nitrile sleeve of 13mm thickness. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
Providing & Fixing PVC rigid drain pipe 20mm (3/4") dia of Diplast/ finolex make complete in all respects from indoor unit to disposal points as directed by Engineer in charge complete in all respects.
Providing and Fixing of voltage stabilizer 4 KVA for AC of 1.5 /Ton and above with MCB, TDR volt meter copper winding input range 180-250 volt single phase including cost of copper wire from stabilizer to A.C unit with M.S. Body of 22 guage sheet powder coalted. Make: V-Guard/ Microtek/ Luminous Warranty of 1 Years.
Supply & laying PVC insulated Aluminum Conductor armoured ISI Marked cable of 4 Core 70 mm sq in Trench/Pipe. Supply & laying of ISI marked 4 core 70 mm sq PVC Insulated Aluminum conductor armoured cable (PVC Sheathed) of make Havells/ Finolex/ Cirtina/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable to be laid in trench/ pipe as per DSR Code 7.5.1 MV CB PIP-25 Part-II (External). The work shall be executed to the entire satisfaction of Engineer-in-Charge. The specification of the cable as below:- i) Conductor – Aluminum ii) Core – 4 iii) Working Voltage – 1100 V iv) Nominal Cross Section – 70mm2 v) Minimum No. of Wire – 7/6 The work shall be executed to the entire satisfaction of Engineer-in-Charge.
Supply & laying PVC insulated Aluminum Conductor armoured ISI Marked cable of 4 Core 95 mm sq in Trench/Pipe. Supply & laying of ISI marked 4 core 95 mm sq PVC Insulated Aluminum conductor armoured cable (PVC Sheathed) of make Havells/ Finolex/ Cirtina/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable to be laid in trench/ pipe as per DSR Code 7.5.3 MV CB PIP-25 Part-II (External). The work shall be executed to the entire satisfaction of Engineer-in-Charge. The specification of the cable as below:- i) Conductor – Aluminum ii) Core – 4 iii) Working Voltage – 1100 V iv) Nominal Cross Section – 95mm2 v) Minimum No. of Wire – 7/6 The work shall be executed to the entire satisfaction of Engineer-in-Charge.
Supply & Laying of DWC pipe 103/120mm Without bockey:- Supply and Laying of pipe (OD-120 mm & ID-103 mm nominal) Double Wall Corrugated (DWC) Without Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, anti rodent, inflammable & good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930, complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling of digging including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Zen, Duraline, Crescent, Sunrise. The entire satisfaction of Engineer-in-Charge of work.
Wiring in existing conduit: Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. Universal/ Finolex/ Polycab/ KEI/ Havell's/ Cirtina or Technically equivalent. The specifications complete in all respect and to the entire satisfaction of Engineer-in-Charge. Size 3 x 2.5 mm2
PVCCON S/F PVC Conduit: Supplying & Fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. The work shall be executed to the entire satisfaction of Engineer in charge. 25 mm
Wiring in existing conduit: Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. Universal/ Finolex/ Polycab/ KEI/ Havell's/ Cirtina or Technically equivalent. The specifications complete in all respect and to the entire satisfaction of Engineer-in-Charge. Size 3 core x 6 mm2
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size G.I. box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supply & Erection of 1x18/20 watt retrofit LED tube rod Supply & Erection of 1x18 watt retrofit LED tube rod made of aluminium housing with PC diffuser or its equivalent specification Lumen out put should be more than 100 lumens per watt (1800 LUM) with LM 79 report from NABL. The make of the fittings should be Panasonic/ Phillips/ Wipro/ Osram/ Surya/ Twinkle. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
S/E of Ceiling Fans 1200mm sweep without fan regulator including M.S. pipe as per site requirement and wiring complete in all respect Make Panasonic- Captor Kraft/ Havell's/ Bajaj/ Philips/ Crompton/ Orient including making connection with 23/.076' flexible wire to be adjacent fan point with regulator. The work shall be executed to the entire satisfaction of Engineer in charge.
Supply & Erection of Exhaust Fan (450mm) 900 RPM of Panasonic/ Havell’s/ Bajaj/ Philips/ Crompton make complete with motor blades along with louver to be installed on existing hole in wall/ glazing with suitable arrangement. The rate includes cost of all labour, carriage to site, testing, commissioning of Exhaust fan & connection to existing light panel. The job shall be executed to the entire satisfaction of Engineer-in-charge.
Dismentling and re-erection of Electric Panel board system including proper cable and wiring setup after shifting in community centre sector 38 west.The job shall be executed to the entire satisfaction of Engineer-in-charge.
Supply and erection of DWC pipe 90/76 mm on wall with help of metal clamps & accessories required for fitting. The job shall be executed to the entire satisfaction of Engineer-in-charge.
Point wiring in PVC conduit, with modular type switch: DSR 1.10.3 Wiring for light point/fan point/exhaust fan point/ cal bell point with 1.5 sq.mm FR PVC insulted copper conductor single core cable in surface/ recessed PVC Conduit with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. Group-C
Supplying and fixing of modular type electronics fan regulator:- Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
S&E of Mouled Case Circuit Breakers (MCCB) of rating 200 Amp with Breaking Cap 26 kA, 415 Volts. Supply & Erection of 4 pole, 26 kA, 63 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
S/F’C series, SP MCB Supply and fixing 6 amps to 32 amps rating, 240 volts ‘C’ series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB Complete with connections testing and commissioning etc as required. Single pole 16 Amps “C” series Make of Anchor, Havells, Legrand, ABB, Siemens, L&T. The work shall be executed to the entire satisfaction of Engineer in charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 8.04 MB
BOQ_110530.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid