| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹2.8 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹2.9 Cr+₹6.4 L (2.29%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | ₹2.9 Cr+₹6.4 L (2.29%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹2.9 Cr+₹11.5 L (4.07%)Rejected-Finance | ₹2.9 Cr+₹11.5 L (4.07%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹3.0 Cr+₹17.7 L (6.28%)Rejected-Finance H NO 411 SECTOR 4 CHANNI HIMMAT JAMMU 180015 J K | JAMMU | JAMMU | J K | 180015 | ₹3.0 Cr+₹17.7 L (6.28%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹3.1 Cr+₹23.9 L (8.50%)Rejected-Finance | ₹3.1 Cr+₹23.9 L (8.50%) | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
18 Mar 2021, 6:00 pmClosed
CE Udhampur Zone
CE Udhampur Zone PO Garhi, Udhampur PIN-182121
PROVN OF HARDSTANDING WITH MANGER, AT STORES AND HAY SHEDS AT UDHAMPUR UNDER GE NORTH UDHAMPUR
2020_MES_403180_1
87849-A/E8
Open Tender
Civil Works
Lump-sum
450 days
Udhampur
As per NIT
9 documents required · 9 mandatory
₹2,000
GE North Udhampur
₹2.0 L
Yes
22 Apr 2021
14 Dec 2020
22 Mar 2021
14 Dec 2020
18 Mar 2021
4 Mar 2021
Amount
Total Amount of Sch 'A' Part - I (Building Work)
Total Amount of Sch 'A' Part - II (Site Clearance)
Total Amount of Sch 'A' Part - III (Internal Electrification)
Total Amount of Sch 'A' Part - IV (Sewage Disposal)
Total Amount of Sch 'A' Part - V (Road, Path & Hardstanding )
Total Amount of Sch 'A' Part - VI (Area Drainage)
Total Amount of Sch 'A' Part - VII (Protective Work)
Total Amount of Sch 'A' Part -VIII (External Electrification)
Total Amount of Sch 'A' Part - IX (External Water Supply)
Sch 'A' Part - X (Misc Items work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
MCB, single pole, 6 to 32 Amp, `C' series, 10KA, 240 Volt, complete all as specified.
MCB, single pole and neutral, 6 to 32 Amp, `C' series, 10KA, 240 Volt, complete all as specified.
MCCB TPN DPX3 thermal magnetic of 25 Amp 16 KA complete with making connection with necessary copper lugs on existing LT FBP complete making provisions for mounting the same on FPB with 10 sqmm single core copper conductor cable, complete all as specified.
LED flood light fitting pressure diecast aluminum body Eco friendly, low consumption energy saving type of 60/70 watt, IP-65 of input range 70 V to 300V 50 Hz with power factor more than 0.9, 9000Lmn with surge protection of colour temperature 6500 K complete with suitable MS Channel, clamps nut bolts etc, complete all as specified.
LED tube light 18/20/21 Watt, 4 feet with LED tube rod integrated type lP20, lumen output>95lum/w, color temp 5700-6500K, CRI>80, THD<20%, PF>0.9, operating voltage 140-270V, extruded aluminum housing in poly carbonate cover body with all accessories prewired and connecting electrically to ceiling rose, complete all as specified and directed. Make: Crompton Cat Part No. LCTL-18-CDL or technically and commercially equivalent models of Philips/Bajaj/Wipro /GE/Syska/ Surya/Havells as approved by the GE.
Steel tubular swaged pole complete with base plate welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed (PCC, earth work shall be measured & paid separately under respective items).
PVC insulated Copper conductor cable (two runs) ISI marked 1100V Grade, 2x2.5 Sqmm FRLS multistranded from pole junction box tio flood light fitting through existing PVC conduct incl making necessary electrical connections all as specified and as directed.
Glass fiber reinforced UV protected poly carbonate junction box IP-66/67 dust/water proof, with knockouts for cable entry of size 10-16 sqmm cable to mounting on the street light pole of size 155mmx210mmx92mm complete with 01 No MCBSP 10 Amps and two number Aluminium bus bar with provision of cable glands and necessary clamps to fix on tubular pole, complete all as specified and directed. Make: Sintex /Hensel/Universal switch gear control
PVC conduit 25mm bore ISI marked alongwith electric pole (Steel Tubular) completion with suitable MS clamps of 16mmx3mm, nut and bolts and washers all as specified and as directed.
XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 16 Sqmm 4 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. (Earth work, brick protection and sand cushioning shall be measured and paid for separately).
Factory made, manufactured by a CPRI approved manufacturer, self supporting totally enclosed LT Feeder Piller Box dust & vermin proof of suitable size to accommodate (01 MCCB TPN 25 Amp 16 KA as incomer and 03 MCB SPN 16 Amp ) suitable for 440 Volts, 3 Phase 4 wire system made out of 2.0mm thick CRCA Sheet and built upon rigid frame work having front and rear hinged door with neoprene rubber gasket epoxy powder coated, earthing strip point complete with aluminum bus-bar suitable for 100 Amp supported with suitable size of heavy duty porcelain stand lock with suitable size bars, nut, bolts and washers with heat shrinkable PVC sleeving . The bus-bar shall be colour coded (Red Yellow and Blue ) for 3 Phase and Neutral including incoming / outgoing cable holes at bottom, embedded with 50x6 mm mild steel angle Iron frame and 200 mm above the normal ground level complete with foundation in cement concrete 1:2:4 (using 20mm graded crushed stone aggregate) and testing after Installations complete all as specified. Note: Rate of MCCB , MCB and complete control wiring are deemed to be to be included in the rate quoted by the tenderer.
XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 10 Sqmm 2 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. (Earth work, brick protection and sand cushioning shall be measured and paid for separately).
100mm dia Sluice value, Wedge/Bronze rings/SS 410 Shaft Constructiobn, Class-1 IS:14846 and ISI marked, PN-1, both end flanged and drilled and fixed with bolts and nuts and washers including providing rubber insertion of suitable thickness complete all as specified and as directed.
80mm dia Sluice value, Wedge/Bronze rings/SS 410 Shaft Constructiobn, Class-1 IS:14846 and ISI marked, PN-1, both end flanged and drilled and fixed with bolts and nuts and washers including providing rubber insertion of suitable thickness complete all as specified and as directed.
10000 litres capacity rotational moulded polyethylene water storage tank (cylindrical vertical type), hoisted and fixed in position complete with and including RCC foundation of min 4m height, complete all as specified and as directed.
Cutting existing CI pipe 250mm bore and reducing to required length in position for insertion of new Tee, branches, complete all as specified and as directed.
Construction of valve pit (Brick masonry) of size 910mm x 910mm x 550mm internal dimension, complete, all as specified and as shown on drawing No. CEUZ/TD/1500/15.
Construction of valve pit (Brick masonry) of size 1200mm x 1200mm x 1200mm internal dimension, complete, all as specified and as shown on drawing No. CEUZ/TD/1500/15.
R K BUILDERS
M/S Inderjit Sharma and Co.
Mehar Enterprises
bamral builder
M/S BHATIA BUILDERS AND CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .