| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹34.4 L+₹61,742.69 (1.83%)Rejected-Finance 602 TECHNOLOGY APARTMENTS 24 1 P EXTENSION DELHI 110092 | DELHI | DELHI | DELHI | 110092 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹36.7 L+₹2.9 L (8.65%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹38.1 L+₹4.3 L (12.8%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹39.3 L+₹5.5 L (16.4%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
27 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Provn of Commercial Power Supply at Air Force Station Jaisalmer
2020_MES_348731_1
8663/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jaisalmer
As Per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹86,000
Yes
3 Jul 2020
1 Jun 2020
29 Jun 2020
1 Jun 2020
27 Jun 2020
15 Jun 2020
60 days
Amount
Supply, installing, testing and commissioning of outdoor type step down transformer of capacity 160 KVA, 11 KV/0.433 KV, 3 Phase, 50 Hz, type of cooling ONAN, cooled oil immersed copper wound (at no load), AC, 3 Phase, 50 Hz, capacity former step up/step down, outdoor copper wound type complete with first filling of IS : 335 ISI marked and dehydrated transformer oil with standard fittings, HT 11 KV, 3 Phase, LT, 433 volts, 3 Phase, 4 wire with off load tapings on HT side to vary secondary voltage within limit, all as per IS : 1180 part-I level-III of capacity 160 KVA core type copper wound, oil immersed, naturally cooled, oil nature, air nature (ONAN) with external cooling tubes/fins delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol DYN-11 (Vector group) with neutral brought out on secondary side (LV side) and 7 position OFF circuit tap changer having tapping range at ±7.5% in steps of 2.5% each on HV side to be changed by means of hand operated off load tap changer gear. the maximum temperature rise should not exceed 45 degree Celsius in oil and 55 degree Celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temperature of 40 degree Celsius. The transformer shall be IS 1180 : 2014 marked and shall comprise of the following:- Make : ITE Gurgaon/AE/Voltamp (a) 3 Nos porcelain HT bushing with brass/gun metal busing rod complete with nut and washers on primary (HV) side suitable for HT, 11 KV, XLPE cable of size 3 core 95 Sqmm.
(b) 4 Nos porcelain bushing rods compele with nut and washers on secondary (LV) side, with brass/gun metal busing rods complete with nut and washers on secondary (LV) side, suitable for LT, 11 KV/ 0.433 KV, XLPE cable of size 3.5 core 185 Sqmm (c) Oil conservator with filter type drain valve and oil level gauge (d) Dehydrating breather with first fills dehydrating agents (Silica gel) (e) One cable box on HT side (Primary side ) consisting of 03 No of porcelain bushing with copper rod, complete with nuts and washers with two numbers cable glands suitable for reception /taking out of XLPE insulated heavy duty armored cable including glands, joints and jointing material complete. (f) Explosive vent (g) Thermometer pocket on tank cover. (h) One number 100mm dia, dial type thermometer, vapour pressure type having range 0-120 degree Celsius with metal guard having max perimeter reading temperature indicator with resisting device for transformer. (j) Two earthing terminal on tank cover to facilitate fixing of 32x6mm GI earth strip for earthing of neutral and body. (k) Rating plate and terminal marking plate. (l) Oil level gauge (m) Oil drain filter valve (n) lifting legs (o) Oil filling holes with cap/plug with connecting plate complete (p) Air release valve plug
(q) Four plain solid cost steel detachable rollers (r) Extra bushing for neutral, outside LT cable box for proving independent earthing for neutral. (s) First filling new and unused transformer oil IS-335/93 (forth version) marked (Make-Savita/power oil) filtered and tested upto 40 KV dia-electric strength at 2.5 mm air gap between testing electrode. Note : Certification of die electric strength shall; be submitted by the contractor after filling the oil. (r) One N 100mm dia dial type thermometer, vapour pressure type having range 0-120 degree celsius with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer. (u) Two earthing terminal to be provided digaonally on either side of tank cover to facilitate fixing of 50x6 mm Galvanised Iron earth strip for earthing of neutral and body. (v) Neutral Grounding Resistance (NGR) shall be provided of suitable rating and design for enhancing the resistance of the neutral. (w) Cost of foundation, NGR and control wiring shall be deemed to be included in the quoted for the transformer by the Tenderer. Note:- (i) Foundation for outdoor transformer and Chain link fancing around of transformer is included in qouted rates by the tenderer.
Supply, installation, testing and commissioning of indoor automatic/servo voltage controller three phase, 50Hz oil cooled of 160 KVA for automatic controlling/regulating of voltage comprising of auto transformer, buck and boost transformer (cooper wound with new filtered & Dyhdrated transformer oil), servo motor, auto controlled solid state central circuit (suitable for supply from DG Sets also) and other fitings and accessories as under, voltmeter (0-300V) to read input/output voltage per phase, mains/low high limit indicators anual increase/decrease push switch, auto/manual mode control switch and output adjustment suitable for both unbalanced and balanced load and overload and short circuit trip facility with input voltae on single phase 208 to 280V, three phase from 360 to 480 V and output voltage on every single phase 240 +/- 2.5% V and on three phase 415+/- 2.5% vanoutand with following featurers :- (a) Electronic control circuit. (b) Low voltage cut off (c) High voltage cut off. (d) Single phase preventor (e) Time delay (f) Toggle switch provided to by pass low/high voltage cut-off switchgear. (g) Overload and short circuit trip facility. (h) Servo by pass switch Make : ITE/APLAB/POWER WAVE
Supply, installation, testing & commissioning of 11 KV, 18.40 KA, 3 Phase, 50 Hz, 3 wire totally enclosed metal clad, extensible type outdoor floor mounted horizontal draw horizontal isolation type vacuum circuit. RMU floor mounted with internal eletrolytic grade copper bus bars, consisting of combinations of 630 Amp motor operated spring charged having rupturing capacity 350 MVA and consisisting of the following (for incoming) (One incomer + 02 Nos of outgoing = 03) 01 No VCB + 2 Nos LBS. fixed type manual Vacuum Circuit Breaker. All live parts, bus bars, LBSs connections of RMU shall be enclosed in on tank to avoid multiple inter connections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694.
Altitude of installation upto 1000m as per IEC 60120. Extensible Bushings, if applicable shall be bolted type top mounted outside the tank for connection of external bus bar. Also, the outer enclosure shall cover the full length of the switchgear, to ensure IP3X+IP54 protection for cable boxes . RMU should be SCADA Compitable. (a) Housing for circuit breaker carriage -01 (b) Mechnical inter lock and automatic safety shutter gear including pad locking arrangement - 01 (c) Isolating plugs - 06 (d) 01 No 11 KV 800 Amp, VCB comprising of (i) Assembly of 3 vaccum interriupters complete with epoxy support insulator and self aligning finger type isolating contacts. (ii) Hand and motor (220 volt AC) charged independent spring closing/tripping trip free operating mechanism with manual closing and tripping push buttons and mechanical breaker closed/open spring charged/discarged indication. (iii) Electrical release coil 24V DC - 01 No (iv) Mechanical operation counter (v) Breaker operated auxiliary switch - 03 Nos. (e) Bus bar chamber including a set of 3 Phase 630 Amp copper bus bar - 01 No (f) 230 volts AC single phase 80W rated strip type heater - 02 Nos with indicator complete.
(p) 3 Phase RYB indications with lamp & holder -01 set with cable glands of suitable size. (q) Trip circuit healthy indication lamp with push button - 01 (r) Power factor meter digital type - 01 (s) Frequency meter - 01 (t) Cable gland of suitable size. (u) shunt trip 24 volts DC power pack having 230 volts AC Supply incoming and 24 Volts DC Supply outgoing including maintenacne free battery bank, battery charger. (v) In built integral earthing (w) Electronic, digital KWH meter CT type suitable for metering CT-01No. Make :- ABB/Siemens/Schneider
Supply, installation, testing and commissioning of indoor type oil cooled isolation transformer 160 KVA, three phase, metalic body, unbalanced type copper wound with standard fittings and accessories, input voltage of 415 volt + 5% output voltage 415 volt+ 5% of frequency 50Hz and with following description including first fill of transformer oil:- (a) Method of cooling - Oil cooled. (b) Ratio - 1: 1 (c ) Insulation class -Class -E (d) Winding Temperature - Less than 55* C (e) Full load lossess- Less than 5% (f) No load lossess - Less than 0.5% (g) Mounting - On wheel detachable type (h) Earth to Neutral voltage - Less than 01 volt. Make : ITE / APLAB/ POWER WAVE
Supply, laying, jointing and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty HT electric power cable (ISI marked) with aluminium conductor 11000 Volt, grade cross sectional area 95 sqmm 3 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed. Make : Polycab/Havells/KEI.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 185 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed by Engineer-in-Charge. Make : Polycab/Havells/Paragon.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 120 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed by Engineer-in-Charge. Make : Polycab/Havells/Paragon
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed by Engineer-in-Charge. Make : Polycab/Havells/Paragon
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed by Engineer-in-Charge. Make : Polycab/Havells/Paragon
M&L for cable jointing kit for 11 KV (Earthed) grade HT cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sqmm 3 core to 95 sqmm 3 core complete all as specified and directed. Make : M-Seal/Y-Denson/Raychem
M&L for Earthing complete with galvanished earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to galvanished iron earth lead strip 32mmx6mm upto 7.50 metre, by means of GI nuts, bolt, check nuts, washers, thimbles, etc as shown in electrical plate No 5 SSR Part-I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exceeding 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe light grade 20mm bore for watering and 50mm bore GI pipe light grade for earth wire protection fixed with poles with two clamps, made from earth lead strip 32mm x 6mm, bolts, nuts and washers, 80mm thick pre cast RCC cover 1:2:4, type B-1, reinforced with hard drawn steel wire fabric wieghing not less than 4 Kg/Sqm in lieu of CI cover etc complete all as specified. Note : (i) The unit rate shall be deemed to included for Test point, 32mmx6mm GI strip from top of the earth plate upto 7.50m above ground level. In case, GI protection pipe required is less than 7.50m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate quoted by the tenderer.
Supply & install, testing & commissioning of LT cubical panel board of outdoor type comprising of 4 Nos copper bus bar 50x5 mm including multi functional digital meters to read volage, current frequency, hooter, and power factor, having individual compartment type made out of MS sheet 3.15mm thick and angle iron frame of 40x40x6mm thick including mounting legs of same angle iron 50cm long embedded in PCC foundation 1:2:4 type B-1 complete suitable for 3 phase 415 volt dust and vermin proof both side openable with locking arrangement, proper slanting projection and having required cable entry glands of suitable size including stud type aluminium cable lugs for incoming and outgoing cables of suitable sizes including painting of LT cubical panel with two coats of emameled paint over a coat of red oxide zinc chrome primer complete all as specified and directed with and including the following:-
(a) MCCB 415 Volt, 4 Pole, 250 Amps, 50 kA - 01 No. (In coming) (b) MCCB 415 Volt, 4 Pole, 160 Amps, 36 kA - 01 No. (Out going) (c) MCCB 415 Volt, 4 Pole, 100 Amps, 25 kA - 02 No. (Out going) (d) Set of indicating lamps (RYB) - 01 Set (e) Warning Lamps. (f) Audio alarm with acknowledge button. Make : Universal/Power System & control/Bafna Electricals Co., Jodhpur
Supply, installation, commissioning and testing of tripode ring earthing system to construct earthing of resistance not more than 01 ohm mainly consisting of 250 micron pure copper high tensile low carbon steel rod earth electrode of minimum 3.0m length, 50mm dia with copper strip of size 20x3.15mm for inter connection to earth electrode and for connected to equipment as per required length, with set of steel nut and bolts, earth enhancement material of mainly consisting of Jamfill compound 50 kg (25 x 2 bags in each pit) jam fill to provide maximum contact between the electrode and jam fill compound. Back fill compound. Jam fill compound shall be eco friendly having CPRI certification, Earthing shall be maintenance free and does not require regular manual addition of water and PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) earth chamber and Earth Pit cover 300 x 300mm. Make: JMV earthing/Daksh Power Solutions/Ashlok Note: (i) Copper strip of size 20x3.15mm required to connect the electrode shall be passed through GI pipe of suitable size. (ii) Copper strip beyond earth test point shall be mearued and paid for seperately. (iii) Quoted rate deemed to included the cost of excavation and earth work, PCC pit, funnel and cover etc.
S&F Copper strip 20x3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified.
Surfaces excavation not exceeding 30cm deep and averaging 15cm deep & getting out in soft/disintegrated rock complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and getting out hard/dense soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and getting out soft/disintegrated complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and getting out hard rock complete all as specified and directed.
Excavating in post holes (or similar holes) each not exceeding 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in soft/disintegrated complete all as specified and directed.
Excavating in post holes (or similar holes) each not exceeding 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in hard rock complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in rock complete all as specified.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
Removal of excavated rock/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
M&L for stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
M&L for dry sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
Material and labour for 100mm thick hardcore of broken stone of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified.
M&L for PCC (1:2:4) Type B-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete for foundation of walls complete all as specified and directed.
M&L precast RCC 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs of drains, manholes etc. including placing in position and set in CM (1:6) complete all as specified & as directed.
M&L for 150mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in floor, finished even and smooth without using extra cement, complete all as specified & directed
M&L for PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in coping benching, including use and waste of form work (straight or curved) complete all as specified.
M&L for Precast cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) as in solid block masonry, exceeding 10cm in width and setting in cement and mortar (1:6) complete all as specified
M&L 100mm thick Cement Concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection, sub-floors, sub-bases and surface etc and finished without using extra cement including construction joints at every 2.40m and change of direction filled with bitumastic (1:3) complete all as specified.
M&L for PCC (1:4:8) Type D-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete for foundation of walls complete all as specified and directed.
M&L 100mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in plinth protection, sub-floors, sub-bases for floor complete all as specified.
M&L for squared rubble walling Jodhpur type, regular coursed, well bonded, bedded and solidly hearted, built in cement and mortar 1:6 complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from straight edge held not exceeding 20mm and dressing of face beds and joints as specified to squared rubble walling, Jodhpur type, brought upto courses complete all as specified and directed.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
M&L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm long and diameter of neck in 5mm to 10mm complete all as specified.
M&L for Mild steel rag or lewis bolts of dia 20mm, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exceeding 30cm long complete all as specified.
M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolts or welded attachment, Fe-290 (Gde E-165) complete all as specified.
M&L for mild steel work in hollow/tubular sections as in columns/ stanchion/ purlins/ trusses including special shaped washer etc. complete using ERW or induction butt welded pipe/tubes conforming to IS-1161-1979 grade St-240, complete all as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges for roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
M&L for rendering 10mm thick on concrete surfaces of any description in cement mortar (1:4) and finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-charge.
M&L for rendering 15mm thick in cement and mortar (1:6) on stone masonry or surface other than fair face of brick work or on one side of lathing complete all as specified and directed by Engr-in-Charge.
Material and labour preparation of newly plastered or unplastered surface of walls & applying three coats of white wash complete all as specified.
M&L for forming construction joints with concrete cutting mechines 30mm deep x 10mm wide and filled with bituminous sealing compound Grade ‘B’ complete all as specified.
M&L for forming contraction (dummy) joints with concrete cutting mechines 65mm deep x 10mm wide and filled with bituminous sealing compound Grade ‘B’ complete all as specified.
M&L for Finishing surface of concrete roads, pavements, by brooming complete all as specified.
M&L for prepariation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M/s Ramesh & Company
SANJOLI CONSTRUCTION COMPANY
Godara Construction and General Suppliers
S.G.ENGINEERING COMPANY
MAHAVIR CONSTRUCTION CO
Rasam Engg Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .