| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹71.4 L+₹3.8 L (5.58%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹72.6 L+₹5.0 L (7.42%)Rejected-Finance NETAJI SUBHAS ROAD SUBHASPALLY SILIGURI 734001 | SILIGURI | DARJEELING | WEST BENGAL | 734001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹73.3 L+₹5.7 L (8.45%)Rejected-Finance OLD HASIMARA PO HASIMARA DISTT ALIIPURDUAR WB PIN 735215 | HASIMARA | ALIPURDUAR | WEST BENGAL | 735215 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical The firm is enlisted in two class below eligible class i.e class C |
Tender Value
₹68 L
EMD Value
₹1.3 L
Closing Date
19 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bengdubi
Headquarters Commander Works Engineers Bengdubi, Post - Bengdubi Distt - Darjeeling (WB) PIN- 734424
REPAIRS TO CENTRAL AND PACKAGE TYPE A.C. PLANTS WITH ALLIED WORKS AT CERTAIN LOCATION AT BENGDUBI STN UNDER GE BENGDUBI
2022_MES_530443_1
8135/B/E8
Open Tender
Electrical and Maintenance Works
Item Rate
360 days
GE BENGDUBI
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE Bengdubi
₹1.3 L
23 Aug 2022
13 Jun 2022
26 Jul 2022
13 Jun 2022
19 Jul 2022
4 Jul 2022
60 days
Amount
Dismantling & removing of compressor of 17 TR capacity (Make: Accel, Model No. SMC 6-65) after disconnecting all electrical connection, gas line, removing nuts, bolts etc from base plate, dismantling the compressor head, removing all defective parts, facing of compressor head, re-assembling the compressor head after replacement of head gasket and other defective parts as required including cleaning, servicing and overhauling of the compressor, re-installation, commissioning and testing, complete all as specified and as directed. Notes:- (a) Cost of all the transportation, repairs & replacemnts etc required for making the compressors fully functional shall be deemed to be included in the quoted rates of above item, however payment for spares will be measured and paid separately under respective items here-in-after as' supply only'. (b) The repairs included in the above item shall be got carried out in only one of the compressor workshop subject to written approval of GE:- (i) H. Brothers, 58, Elliot Road, Kolkata-700016. (ii) M.P Engineering Works, 2/M Radha Govinda Saha Lane, Kolkata-700017. (iii) Air-cool Technic, 42/66 New Bullyganj Road, Kolkata-700039. (iv) Paul Engineering Works, 61, Lenin Sarni, Kolkata-700013. (v) Capital Refrigeration, 775, Fartabad Road, Kolkata. (c) Supply only additional refrigerant, if required shall be measured and paid for separately. (d) Supply only compressor oil for topping up, if required shall be measured and paid for separately.
All as per item No. 1 here-in-above but for 10/11.5 TR capacity (Make: Accel, Model No. SMC 4-65) complete all as specified and directed.
All as per item No. 1 here-in-above but for 15 TR capacity (Make: Freezeking, Model No. FK-1500) complete all as specified and directed.
Supply only Piston pin, Part No E-13, Make ACCEL/K-nine, for compressor of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Piston ring, Part No E-15, Make ACCEL/K-nine, for compressor of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Scrapper ring (Oil ring) Part No E-16, Make ACCEL/K-nine, for compressor of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Suction valve ring plate, Part No F-04, Make ACCEL/K-nine, for compressor of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Discharge valve reed, Part No F-20, Make ACCEL/K-nine, for compressor of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Neoprene ‘O’ ring for shaft seal, oil pump, oil regulator valve, oil valve, valve gland, Part No J-06, Make ACCEL/K-nine, for compressor of Make ACCEL, Model No.SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Piston (standard size), Part No E-14, Make ACCEL/K-nine, for compressor of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Main Bushing with collars STD, Part No C-03, Make ACCEL/K-nine, for compressor of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Rear Bushing with collars STD, Part No C-03, Make ACCEL/K-nine, for compressor of Make ACCEL, Model No.SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Connecting rod big end bush, Part No E-06 , Make ACCEL/K-nine, for compressor of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Connecting rod small end bush, Part No E-02, Make ACCEL/K-nine,for compressor of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only bushing for Piston pin for compressor, Part No E-07 , Make ACCEL/K-nine, of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Cylinder liner HSG for compressor Part No F-03, Make ACCEL/K-nine, for compressor of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Oil Pump gear wheel, Part No I-04 , Make ACCEL/K-nine, for compressor of Make ACCEL/K-nine, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Oil Pump bearing Bushing, Part No I-06 , ACCEL/K-nine,, for compressor of Make ACCEL/K-nine, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Hexagonal head bolt, Part No A-12, Make ACCEL/K-nine, for compressor of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Rocker for unload mechanism, Part No G-24, Make ACCEL/K-nine, for compressor of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Connecting rod, Part No E-01, Make ACCEL/K-nine, for compressor of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Gasket set complete of Make ACCEL/K-nine, for compressor of make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Aluminum packing washer set of Make ACCEL/K-nine, for compressor of make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Nut & Bolt for connecting rod, Part No E-08, Make ACCEL/K-nine, for compressor of Make ACCEL, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Dowtyring for compressor of Make ACCEL/K-nine, Model No. SMC 6-65 & 4-65, complete all as specified and directed.
Supply only valve spring suction/discharge, Part No M-06, Make ACCEL/K-nine, for compressor of Make ACCEL orequivalent, Model No SMC 6-65 & 4-65, for complete all as specified and directed.
Supply only Thrust washer for main bush, Make ACCEL/K-nine for compressor Make ACEEL, Model No SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Unloading ring with pin, Part No F-12, MAKE: ACCEL / K-Nine for compressor of Make ACCEL, Model No.SMC 6-65 & 4-65, complete all as specified and directed
Supply only Coupling piece for oil pump, Part No I-04, MAKE: ACCEL / K-Nine for compressor of Make ACCEL, Model No.SMC 6-65 & 4-65, complete all as specified and directed
Supply only Discharge Valve Assembly, Part No. F-15, MAKE: ACCEL / K-Nine for compressor of Make ACCEL, Model No.SMC 6-65 & 4-65, complete all as specified and directed.
Supply only Suction valve retaining plate, Part No F-06, MAKE: ACCEL / K-Nine for compressor of Make ACCEL, Model No.SMC 6-65 & 4-65, complete all as specified and directed
Supply only Crank shaft with shaft key and key guard, Part No D-03, MAKE: ACCEL / K-Nine for compressor of Make ACCEL, Model No.SMC 6-65 & 4-65, complete all as specified and directed
Supply only Oil pump, Part No I-01, MAKE: ACCEL / K-Nine for compressor of Make ACCEL, Model No.SMC 6-65 & 4-65, complete all as specified and directed
Supply only Discharge leaf, Part No. 6-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freezeking, Model No. FK-1500, complete all as specified and directed.
Supply only Suction leaf, Part No 12-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Piston Pin, Part No 72-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Piston Ring, Part No 93-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Main bush Bearing, Part No. 52-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Rear bush bearing, Part No. 53-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Connecting rod big end bush, Part No. 67-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed
Supply only Connecting rod small end bush, Part No. 66-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Piston pin bush, Part No. 73-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Piston Standard size, Part No. 89-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Cylinder liner, Part No. 13-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Hexagonal head bolt, Part No. 8-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Gasket set, Part No. 97-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Oil pump bush bearing, Part No. 39-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Oil pump gear wheel, Part No. 38-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Connecting rod, Part No. 64-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Oil pump , Part No. 37-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed.
Supply only Crank Shaft with shaft key and key guard, Part No. 62-1500, MAKE: Freezeking / K-Nine, for compressor of 15 TR capacity of make Freeze King, Model No. FK-1500, complete all as specified and directed. Notes for Item NO 04 to 51 :- (i) These shall be of make ACCEL/K-nine/ Freez King and of Part No as mentioned in the respective items suitable for the existing compressors of make and model No as mentioned. (ii) The quantity of these items shall be operated only to the extent required replacement under items No 1 to 3 here-in-before.
M & L for dismantling condenser connections for descaling, plugging them and providing 15 mm bore tee outlet for local circulation of mild acid solution in the condenser (separate container and small pump set to circulate mild acid solution shall be used). The PH value of solution shall be 4 and it shall be checked frequently i.e. every 1 hour during the operation. The Scalgun WS solution or equivalent solution as approved by the GE shall be used for discaling purpose. After 2 to 3 hours of cleaning, if the PH value remains less than 7, flush with fresh water added with sodium carbonate. After above process, the end covers shall be opened and condenser tubes shall be cleaned with Nylon brush, subsequently after closing the end covers, circulate mild acid solution as specified above and PH value shall be maintained as above, flushing the same with fresh water including recharging of stored refrigerant upto required pressure complete all as specified and directed for 34/23/20/15/TR Plant Capacity. Notes: The quoted rates shall also be deemed to include the following elements:- (a) The solution shall be warmed upto 35 Degree Celsius. (b) During the entire process of cleaning, the PH value of water shall be 7. (c) Provision of solution for descaling, rubber gaskets, washers, nuts, bolts etc as directed.
All as per item No. 52.00 here-in-above but for 39 x 3 TR Plant complete all as specified and directed.
Cleaning and descaling of evaporated coil for flushing out oil from the system of 34 TR capacity by using NO2 (Nitrogen) gas including opening, servicing and re-fixing the existing system, complete all as specified and directed.
All as per item No. 54 here-in-above but for 23/20/15 TR capacity complete all as specified and directed.
Opening of Air Handling Unit, dismantling the unit and taking out the blower shaft, fan, pulley with complete assembly for carrying out inspection of all bearing bush coupling, pulley and overhauling the same and rectification of the defects including replacement of unserviceable parts & re-assembling the same for smooth running after applying approved grade of grease for 34/23/20/15 TR capacity plant, complete all as specified and directed. Note:- The quoted rates shall be deemed to include cost of all the repairs and replacements to make the A.H.U. fully functional, however the payment for spares only will be measired and paid as " supply only" separately under respective item here-in-after.
Supply and fixing high speed bearing No. UC-208/P-206J including housing with both ends sealed, after taking out old one,complete all as specified and directed, Make:- FKS/NTN or equivalent as approved by the GE.
Dismantling of existing earthing and in lieu providing new earthing complete of advance encapsulated compound based (CPRI tested) maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy coated). Zinc coated (80-100) microns with pure zinc(99.9%) & alloy coating (200-250) microns. Earthing system shall be conforming to IS-3034, the outer and inner pipe shall be 76.2mm & 41.9mm dia, 2 metre length Zinc coated with additional special alloy coating 300mm on the topside for additional protection of the terminal annular space between the pipes being filled up with compact fill (CF) (Crystalline conductive compound). The compact fill (CF) mixture shall be machine pressed in the pipes and should not disintegrate or collapse when outer pipe corrodes. The inner pipe shall be extended with terminals for connectivity. The job includes digging the pits and refilling the same by electrodite/ conductolite back fill comopound (Ground Enhancer). The BFC shall be eco friendly, it shall not contain environmentally hazard materials having ROHS certification from NABL accredited lab. The earth pit shall also be provided with earth pit cover for protection and safe guard of terminals. In area where soil condition is bad, good earth shall be provided to fill the excavated pits by mixing the same with BFC, 4 bags (as per soil condition) extra per pit/unit. The earth electrode (the main component of the earthing system) which is in direct contact with the ground shall be able to provide a means of releasing or collecting earth leakage current. The materials shall have good electrical conductivity & anti-corrosion property in wide rage of soil condition and testing on completion including dismantling unserviceable earthing complete all as specified and as directed. Make ASHLOK Model- ASEEL or equivalent of make JMV/True Power as approved by the GE.
Dismantling & removing of mono block centrifugal pump motor unit of capacity 5 HP after disconnecting all electrical connection and water pipe line and transportation to repair workshop, stripping out the motor and pump, overhauling of the pump & Motor, also carrying out the following works, complete all as specified and directed:- (a) Servicing the motor winding by passing hot compressed air and cleaning the winding with Dr. Bracks thinner and applying two coats of anti moisture heat resistance insulating varnish and drying up slowly including replacement of all insulating glass, tubes, amps tapes etc. (b) Metal filling, cutting, grinding, polishing of pump shaft and impeller. (c) Inspection and finding out defects and replacement of defective parts. (d) Re-assembling the motor pump complete after applying approved grade grease, replacement of gland packing and transportation to site, installation, commissioning and testing complete. NOTES:- (i) The cost of transportation of pump and motor to repair workshop and again to the site of work shall also be deemed to be included in the unit quoted rate. (ii) Cost of all the repairs & replacemnts etc required for making the pumpsets (incuding motor) fully functional shall be deemed to be included in the quoted rates of above items, however payment for supply only spare parts will be measured and paid separately under respective items here-in-after. (iii) The repairs of the Motors included under item Nos 79 to 82 are not applicable for the Pumpsets (incl Motors) included in item Nos 59 to 62).
All as per item No. 59 here-in-before but for 3 HP capacity, complete all as specified and direced.
All as per item No. 59 here-in-before but for 1 HP to 2 HP capacity, complete all as specified and direced.
All as per item No. 59 here-in-before but for 10 HP capacity, complete all as specified and direced.
Taking out induction motor of 25 HP capacity, 3 phase, 415 Volts from its existing position after disconnecting all electrical connections and transportation to repair workshop, stripping out the motor, overhauling of the same, also carrying out the following works complete all as specified and directed:- (a) Servicing the motor winding by passing hot compressed air and cleaning the winding with Dr Bracks thinner and applying two coats of anti moisture heat resistance insulating varnish and drying up slowly including replacement of glass, tubes, amps tapes etc. (b) Inspection, finding out and replacement of defective parts, if required. (c) Metal filling, cutting, grinding, polishing of shaft complete. (d) Re-assembling the motor complete after applying approved grade grease, replacement of terminal plate including transportation to site, installation, connection and testing complete all as directed. Notes:- (i) The cost of transportation of motor to repair workshop and again to the site of work shall also be deemed to be included in the unit quoted rate, (ii) Cost of all the repairs & replacemnts etc required for making the Motors fully functional shall be deemed to be included in the quoted rates of above items, however payment for supply only spare parts will be measured and paid separately under respective items here-in-after. (iii) The repairs of the Motors included under item Nos 71 to 78 are not applicable for the Pumpsets (incl Motors) included in item Nos 63 to 70).
All as per item No. 63 here-in-before but for 20 HP capacity motor, complete all as specified and directed.
All as per item No. 63 here-in-before but for 15 HP capacity motor, complete all as specified and directed.
All as per item No. 63 here-in-before but for 10 HP capacity motor, complete all as specified and directed.
All as per item No. 63 here-in-before but for 5 HP capacity motor, complete all as specified and directed.
All as per item No. 63 here-in-before but for 3 HP capacity motor, complete all as specified and directed.
All as per item No. 63 here-in-before but for 2 HP capacity motor, complete all as specified and directed.
All as per item No. 58 here-in-before but for 0.5HP to 1HP capacity motor, complete all as specified and directed.
Taking down induction motor upto 0.5HP to 1 HP capacity, 3 Phase, 415 volts after disconnecting all electrical & pipe line connection and transportation to repair workshop, dismantling the motor starter, removing worn out copper winding, cleaning the starter and rewinding the same with new super enamelled copper wire of existing size and specification and varnishing the same with anti moisture heat resistance insulating varnish and drying up slowly and including replacement of all types of insulating tapes etc and reassembling the same, transportation to site and re-fixing on its existing position and testing complete all as specified and directed Note:- The cost of transportation of motor to repair workshop and again back to the site of work shall also be deemed to be included in the unit quoted rate.
All as per item No. 71 here-in-before but for 2HP capacity motor, complete all as specified and directed.
All as per item No. 71 here-in-before but for 3HP capacity motor, complete all as specified and directed.
All as per item No. 71 here-in-before but for 5HP motor, complete all as specified and directed.
All as per item No. 71 here-in-before but for 10 HP capacity, complete all as specified and directed.
All as per item No. 71 here-in-before but for 15 HP capacity, complete all as specified and directed.
All as per item No. 71 here-in-before but for 20 HP capacity, complete all as specified and directed.
All as per item No. 71 here-in-before but for 25 HP capacity motor, complete all as specified and directed.
Taking down mono block centrifugal pump motor unit of capacity 5HP after disconnecting all electrical & pipe line connection and transportation to repair workshop, dismantling the motor starter, removing worn out copper winding, cleaning the starter and rewinding the same with new super enamelled copper wire of existing size and specification and varnishing the same with anti moisture heat resistance insulating varnish and drying up slowly and including replacement of all types of insulating tapes etc and reassembling the same, transportation to site and re-fixing on its existing position and testing complete all as specified and directed Note:- The cost of transportation of motor to repair workshop and again back to the site of work shall also be deemed to be included in the unit quoted rate.
All as per item No. 79 here-in-before but for 3 HP capacity, complete all as specified and directed.
All as per item No. 79 here-in-before but for 1 to 2HP capacity, complete all as specified and directed.
All as per item No. 79 here-in-before but for 10HP capacity, complete all as specified and directed. Note for Item Nos 59 to 82: The repairs included in there items shall be got executed from the workshop having requisite equipments & resources after obtaing written approval by the contractor from the GE.
Supply only ball bearing 6312 ZZ with water seal cover, nut, bolt, bearing socket etc, complete all as specified and as directed, MAKE: SKF / TATA / NBC.
Supply only ball bearing 6310 ZZ with water seal cover, nut, bolt, bearing socket etc, complete all as specified and as directed, MAKE: SKF / TATA / NBC .
Supply only ball bearing 6308 ZZ with water seal cover, nut, bolt, bearing socket etc, complete all as specified and as directed, MAKE: SKF / TATA / NBC.
Supply only ball bearing 6305 ZZ with water seal cover, nut, bolt, bearing socket etc, complete all as specified and as directed, MAKE: SKF / TATA / NBC.
Supply only ball bearing 6205 ZZ with water seal cover, nut, bolt, bearing socket etc, complete all as specified and as directed, MAKE: SKF / TATA / NBC. Note for item No.83 to 87:- The quantity of these items shall be operated only to the extent required replacement for the item Nos 59 to 70 here-in-before.
Material & labour for carrying the Vacum test in the plant with and including CO2/Nitrogen pressure for leak detecting and for checking the requirement for gas charging, also charging of the Refrigerant & carrying out pressure testing and running the plant of capacity 34 TR plant to obtain the desired conditions, complete all as specified and directed. Note:- Payment for supply only of Refrigerator gas in case required will be measured and paid separately under relevant item of this schedule.
All as per item No.88 here- in - before but for 20/23 TR capacity plant, complete all as specified and directed.
All as per item No. 88 here - in - before but for 17.5/15 TR capacity plant, complete all as specified and directed.
All as per item No. 88 here -in - before but for 3x39 TR Chilling AC plant, complete all as specified and directed.
Supply only charging refrigerant gas MP-39/R-401/R-134a for the central type AC plant including charging kit, complete all as specified and directed, Make:- Honeywell Genetron/Fluoro/Staleon.
All as per item No.92 here - in - before but M-22 gas, complete all as specified and directed, Make:- Navin Fluorine/ Honeywell Genetron/Staleon.
Taking out air filter from air handling unit and cleaning the filter by passing through compressed air and re-fixing the same with and including provision of new necessary machine screws, nuts, bolts etc, complete all as specified and directed.
Dismantling of existing different size suction/discharge control valves and opening the valve unit, overhauling/repairing of the same by lathe work and replacement of necessary Teflon sheet, washers, nuts, bolts, gasket etc, cleaning thoroughly and re-fixing the same complete all as specified and directed.
All as per item No. 95 here - in - above but for liquid line globe valve, complete all as specified and directed.
Dismantling and removing of unserviceable gauge board connection for HP/LP/OP and high/low cut out switch and supply & fixing new connection with and including 6 mm dia copper tube, brass flare nut, tee and also carrying out leak testing, complete all as specified and directed.
Dismantling and taking out unserviceable hand shut off valves & adapter and supply and fixing of new hand shut off valve for pressure gauge, cut out switch including brass adapter of size 1/4" x 1/4", complete all as specified and directed, Make:-TEK/BM/Danfoss or equivalent as approved by the GE.
Dismantling of safety valve and supply & fixing condenser safety valve suitable for 300/350 PSI, complete all as specified and directed, Make:-BAP/PAL/BM/TEK.
Checking all inter locking electrical connection thoroughly of control panel in central type AC plant for any loose/broken connection of main control panel (Relays, power contactors, timer, starter, toggle switches, push button, MCB etc), compressor motor, blower motor, water circulation pumps, CT fan motor, HP/LP cut out, OP cutout, solenoid valves, loading/unloading valves, thermostatic expansion valve, controlling thermostat humidistat of AHU unit etc, taking out PVC insulated burnt/unserviceable cable, repairs/replacement of cable socket /gland epoxy panel insulator, brass nut, bolts screw etc as required at site as per the existing size and specifications and testing complete for satisfactory automatic function of AC plant panel, all as specified and directed. Note : Provision of new copper cable shall be measured and paid for separately.
Supply and fixing Numeric digital Ammeter having display for accuracy for Ampere, square of size 4 inch, 0 to 15 Amps range, flush mounting type including dismantling old one, complete all as specified and directed, Make:-L&T/AE or equivalent as approved by the GE.
Supply and fixing Numeric digital Voltmeter having display for accuracy of voltage, flush mounting square type of size 4 inch, 0-500/0-600 Volt range, including dismantling old one, complete all as specified and directed, Make:-L&T/AE or equivalent as approved by the GE.
Supply and fixing Electronic timer of range 12 -120 sec/3-120 sec, type ST 100/ GT 200, including dismantling old one, complete all as specified and directed, Make:-L&T or equivalent as approved by the GE.
Supply and fixing control circuit MCB SP, 'C' curve, 6 Amp, 10KA with and including necessary connecting wires, socket, gland etc, after taking out old one, complete all as specified and directed, Make:Legrand/L&T/Havells /C&S
Supply and fixing MCB, Triple pole, 6 to 32 Amps, 240 volts, ‘C’ curve, 10 KA after taking out old one, complete all as specified and as directed, Make:Legrand/L&T/Havells/C&S.
All as per item No 94 here-in above but Triple Pole, 50-63 Amps, 240 volts, ‘C’ curve, 10 KA complete.
Supply and fixing 2 way toggle switch of capacity 10/15 Amps including taking out old one, complete all as specified and as directed, Make:-Kayce/SCI or equivalent as approved by the GE.
Supply and fixing push button ON/OFF including taking out old one, complete all as specified and as directed, Make:- L&T or equivalent as approved by the GE.
Supply and fixing indicator lamp (LED) type including taking out old one, complete all as directed, Make:- L&T or equivalent as approved by the GE.
Supply and fixing 3 pole Power Contactor type ML-2, 32 Amps, 415 volts including taking out old one complete, with and including necessary interlocking connections, complete all as specified and directed, Make: L&T/HAVELL's/BCH.
All as per item No. 110 here - in - above but type ML-1.5, 25 Amps, 415 Volts, complete.
All as per item No. 110 here - in - above but type ML-4, 25 Amps, 415 Volts, complete.
Supply and fixing in repairs thermal over load relay with starter and off re-set type ML-2, range 3.5 to 7.5 Amps, complete all as specified and as directed, Make: L&T/ Seimens/ ABB/Schneider/ HAVELL's.
All as per item No. 114 here - in - above but range 13.0 to 21.0 Amps complete.
Supply and fixing relay type MK-1, range 2.5-4 Amps, including taking out old one, complete all as specifed and direceted, Make: L&T/Havells/BCH.
Supply and fixing in repairs Air Brake Power Contactor of 415 Volts, Coil Voltage: 230 V, 50 Hz. MAKE: Siemens/BCH/L&T, complete all as specified and directed.
Supply and fixing in repairs Overload Relay of range 1.6 - 2.5 Amps. MAKE: Siemens / L&T, complete all as specified and as directed.
Supply and fixing single phase preventor having auxillary supply 415 volts bimetal thermal overload relay various ranges starting from 3 Amps to 15 Amps including making interlocking connection with necessary wires, sockets, after taking out old one, complete all as specified and directed, Make:- L&T/Havell's/BCH.
S&F auxillary contact block MNX-A2 including necessary connecting materials after taking out old one, complete all as specified and directed, Make:- L&T/ BCH/ HAVELL's.
S & F in repairs DOL starter 3 phase, 415 volts, capacity 10 HP, submersible type, MN-16 in the LT panel board, complete all as specified and directed, Make: Havells/BCH/L & T/C&S.
Supply and fixing AC power contractor, 3 pole, 415 volt, 50 Hz, Type MNX-25, capacity 10/15 Amps including making interlocking connection with and including protection circuit after taking out old one, complete all as specified and as directed, Make:- L&T/Havell's/BCH/C&S.
S&F electronic timer (Pneumatic timer) with time delay including provision of connection wire, lugs, copper socket for interlocking connection after taking out old one complete all as specified and as directed. Cat Part No. KRTPN-10 Amp, Make - BCH or equivalent of Make:- L&T as approved by the GE.
S&F control flexible cable, two core, round type PVC insulated and PVC sheathed with copper conductor of size 1.00 sq mm including provision of necessary copper socket, nuts, screws of brass after taking out old one, complete all as specified and directed, Make:-HAVELL's/ FINOLEX/ PLAZA/POLYCAB/RR Cable.
S&F control flexible cable 5-core, 1.5sqmm Ribon type cable with flexible cover and pin type male/female socket and cable length1.5M, including making interlocking connection after taking out old one, complete all as specified and directed.
All as per item No. 125 here - in - above but range 10 - core, complete.
Supply and fixing MCCB, 4 P, 400 Amps, 415 volts, 36 KA,100 % Icu, after taking out old one, complete all as specified and as directed, Make: Legrand / ABB / L&T / Havells/C&S
Supply and fixing MCCB, 4 P, 160 Amps, 415 volts, 25 KA, 100 % Icu, after taking out old one, complete all as specified and as directed, Make: Legrand / ABB / L&T / Havells/C&S
Supply and fixing MCCB, 4 P, 100 Amps, 415 volts, 25 KA, after taking out old one, complete all as specified and as directed, Make: Legrand / ABB / L&T / Havells/C&S.
Supply and fixing expansion valve suitable for 34 TR capacity AC plant including providing new necessary connecting accessories after taking out old one, complete all as specified and directed, Make- SPORLAN, Model No. MVE-34-CP-100 or equivalent of make DANFOSS/SANHUA as approved by the GE.
All as per item No. 130 here-in-above but suitable for 12/15/20/23 TR capacity AC Plant, Make – Sporlan, Model No. HVE-11 - CP-100 or equivalent of make DANFOSS/SANHUA as approved by the GE.
All as per Item No. 130 here-in-above but suitbale for Chiller Plant 39 TR, including providing 3 way connection with necessary fittings, Make:- SPORLAN/ DANFOSS/SANHUA as approved by the GE.
Supply and fixing of Temperature and Humidity indicator with sensor suitable for AC plants including provision of necessary copper wire, copper socket , also including taking out old ones, complete all as specified and directed, Make:-Multispan or equivalent as approved by the GE.
Supply and fixing solenoid coil 220/230 volt 50 Hz, 11/15 watt for capacity control valve including taking out old one, complete all as specified and directed, Make:- Rotex/Avcon/Emerson .
Supply and fixing crank case heater 200 W, 230 volts including provision of necessary connection wire with copper nuts, bolts, washers after taking out old one, complete all as specified and directed.
Dismantling of solenoid valve of 34/23/20/15 TR capacity plant and finding out the defects and fixing the same in the position after repairing including replacement of gasket, washers etc, complete all as specified and directed.
Supply & fixing water pressure switch including taking out old one, complete all as specified and directed, Make: Model No. IPS-100 of Make - Indfoss or equivalent of make DANFOSS as approved by GE.
Supply & fixing finned strip air heater 2000 Watt including making necessary connection after taking out old one, complete all as per existing specifications and directed, Make:-TEMCO / MSSE / Dasspass.
All as per item No. 138 here - in - above but 1500Watt, complete.
Supply & fixing high pressure/low pressure cut out switch for gas including taking out old one complete all as specified and as directed,Make: Model MP-15 of Make - Indfoss or equivalent of make DANFOSS as approved by the GE.
Supply & fixing oil pressure cut out switch for oil including taking out old one complete all as specified and as directed, Make: Model MP-55 of make - Indofoss or equivalent Model of Make:- DANFOSS as approved by the GE.
Supply and fixing HP/LP/OP compound gauge comprising high (0-300 PSI), low (-30 to 150 PSI), OP (0-150 PSI) with and including necessary brass adaptor flare nut etc, also including dismantling of old one, complete all as specified directed, Make:-FIEBIG/MICRO/H Guru.
Supply and fixing shaft seal rotary type for compressor of Make ACCEL ; Model No. 4/65 & 6/65 including taking out old one, complete all as specified and as directed, Make:-Dewdrops/K-Nine.
All as per item No. 143 here-in-above but for Compressors of Model No. FK-1500 of Make: K-Nine/Dewdrops or equivalent.
Supply and fixing brass pilot control solenoid valve with operating coil 220/230 volts, 3 way including replacement of copper pipe for connection after dismantling old one for 34 TR plant capacity complete all as specified and as directed, Make: Sporlan Model 180-SWP-500-MOPD-275-NKC-2 or equivalent of Make:- ROTEX/ DANFOSS as approved by the GE.
All as per item No. 145 above but for 23/20 TR capacity plant, 2 way/3 way complete.
All as per item No. 145 above but for 39 TR capacity plant complete.
Supply & fixing Brass liquid line glove valve as per existing size & type suitable for liquid line including provision of necessary fittings and leak testing complete after dismantling old one, complete all as specified and directed, Make:-BM/BAP/TEK
Supply & fixing ball valve of size 1 5/8" including provision of necessary fittings and leak testing complete after dismantling old one, complete all as specified and directed, Make:- Danfoss/Sanhua or equivalent as approved by the GE.
Material & labour for repairing to pipe jointing/flange of suction/discharge liquid line with provision of necessary copper pipe, fittings, nuts, bolts, washers by Bronze/Beijing stick by gas welding set and machinery work as required at site including leak testing, complete all as specified and directed.
Supply and fixing Brass capacity control valve (Load/Unload) for 1/4" pipe line complete with and including 220 volt operating coil, 2/3 way suitable for SMC 6-65/4-65 compressor of Make: ACCEL, also including taking old one, complete all as specified and directed, Make:-Rotex/AVCON/Danfoss or equivalent as approved by the GE.
Supply and fixing dry and wet temperature meter including provision of water container for wet bulb with and including fixing arrangements after taking out old one, complete all as specified and as directed, Make:- JRM/ZEEL or equivalent as approved by the GE.
Supply and fixing thermostatic temperature cut off switch of suitable range including making all connections after taking out old one, complete all as specified and as directed, Make:-Honeywell/Indfoss/Sanhua/Danfoss.
Supply and fixing Brass oil pressure regulating valve after taking out old one complete all as per existing size and type as directed, Make:-ACCEL/ K-nine or equivalent as approved by the GE.
Supply and fixing Brass compressor safety valve assembly including taking out old one, complete all as specified and directed, Make:-ACCEL/ K-nine or equivalent as approved by the GE.
Supply and charging compressor oil of 68 grade complete all as specified and directed, Make:-Zed Plus/SERVO/HP/BP.
Removing the condenser unit (03 Nos), cleaning and descalling of the condenser tube with descalling agent with the help of pump and brushes including replacement of all gasket, nuts bolts and re-assembling of the same for Package Type AC Plant of capacity 8.75 TR, complete all as specified and directed.
Material & labour for Cleaning and discalling of evaporated coil (03 Nos) for flushing out oil from the system for 8.5 TR Package Type A C Plant by using NO 2 (Nitrogen) gas and CTC gas including servicing and refixing the existing system, complete all as specified and directed.
Dismantling all electrical connection of existing AC panel of package unit of capacity 8.75 TR each after disconnecrting all the refrigement lines and electrical connection, removing all the unserviceable parts like micro-processor, display board, timer, contactor, fuses of AC comperssor, blower motor, CT fan motor and replacing all the unserviceable safety devices to improvise new provision to control circuit including making interlocking connection properly to run the compressor smooth, complete all as specified and directed. Note:- Cost of all the repairs and replacements required to make the Panel fully functional shall be deemed to be included in the quoted rate of above item. However payment for spares as 'Supply only' shall be measered and paid for separately under the relevent items.
Supply and fixing controller of Package Unit 8.75 TR, 3 Phase, with necessary copper wires, cable lugs, sockets etc. Model: MPMN 13100A06A of Make: Softhard Automation Pvt Ltd or equivalent Make of Voltas, Bluestar.
Supply and fixing overload relay for PAC Controller for motor type 02MACFAAAAA06 MPD-WOD, range 1-10 A, 230 V AC, with necessary connection materials for package unit of 8.75 TR capacity complete all as specified and directed. Make: Softhard Automation Pvt Ltd or equivalent as approved by the GE.
Opening of Air Handling Unit of 39TR Chiller Plant, dismantling the unit, taking out the blower shaft, fan, pulley with complete assembly for carrying out inspection of all bearing bush coupling, pulley overhauling and servicing of AHU coil, humidifier and rectification of the defects including replacement of unserviceable parts and reasembling the same for smooth running complete all as specified and directed. Note:- Cost of all the repairs and replacements required to make the AHU fully functional shall be deemed to be included in the quoted rate of above item. However payment for spares as 'Supply only' shall be measered and paid for separately under the relevent items.
Supply only compressor heater belt type for scroll compressor of 39 TR chiller unit, complete all as specified and directed. Make:- Danfoss or equivalent as approved by the GE.
Supply only sensor LWT/EWT for chiller unit, complete all as specified and directed. Make:- Danfoss or equivalent as approved by the GE.
Supply and fixing CI actuating valve motorised for 100mm liqud line with necessary interlocking connections of chiller line including sprinkle for humidifier after taking out the old one, complete all as specified and directed, Make: Honeywell or equivalent as approved by the GE.
Supply and fixing 'V' Belt of size B-84 including dismantling old one, complete all as specified and as directed, Make - Fenner/Mitsubushi/Alaska/Nirlon.
All as per item No. 166 here - in - before but of size B-120 complete.
All as per item No. 166 here - in - before but of size B-116 complete.
All as per item No. 166 here - in - before but of size B-76 complete.
All as per item No. 166 here - in - before but of size B-73 complete.
All as per item No. 166 here - in - before but of size B-56 complete.
All as per item No. 166 here - in - before but of size B-66 complete.
S& F V-Belt of size SPA-1600 for chilling plant including taking out old one complete all as specified and directed, Make:- Fenner/Mistsubushi/ Alaska / Nirlon.
Supply and fixing 'V' Belt of size A-28 (for blower motor of 8.75 TR package type AC) including dismantling old one complete all as specified and as directed, Make:- Fenner / Mitsubushi/ Alaska / Nirlon
Supply and fixing water proof roller bearing No. 30204 including housing after taking out one, complete all as specified and directed, Make:- SKF or equivalent as approved by the GE.
Supply and fixing heavy duty micro Pre-filter of size 600mm x 600mm x 50mm, plated and box type, Filter media, Non-woven synthetic media sandwiched between HDPE and aluminium in air duct (as per existing) including necessary fittings after taking out old one, complete all as specified and directed, Make:- Spectrum filteration or equivalent as approved by the GE.
All as per item No. 176 above but of size 450mm x 600mm x 50mm.
Dismantling and taking out compressor/motor pulley and repairing the pulley after re-boring including replacement of pulley bush, key, allan screw and necessary machinery work for key guard and full repairing, refixing the same for proper running with balance, complete all as specified and directed.
S&F Humidifier pump controller for 39 TR chiller plant including interlocking connection after taking out old one, complete all as specified and directed, Make:- Honeywell or equivalent as approved by the GE.
S&F Step Down Transformer for motorised valve with necessary interlocking connection including provision of connecting materials like clamp, socket, box after taking out old one, complete all as specified and directed, Make:- Powro or equivalent as approved by the GE.
S&F Timer for 39 TR Chiller plant including interlocking connection with connecting materials after taking out old one, complete all as specified and directed, Make:- GIC/L&T or equivalent as approved by the GE.
Removing all electrical connection from main control, preparation of old painted steel surfaces by scrapping and brooming down and cleaning oil/greasey spot by using CTC and filling cavities using suitable filling compound to achieve smooth surfaces and thereafter applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer to the exposed steel surfaces of A. C. Plant complete with the following accessories:- (a) Compressor - 3 Nos (b) Compressor motor - 3 Nos (c) Monoblock pump motor - 2 set (d) Blower motor - 1 set (e) L T Pannel Board - 1 set (f) Cooling chember (AHU) - 1 set (g) Suction/Discharge/water line (h) Foundation channel/frame (j) Condenser - 3 sets (k) Cooling Tower
Removing all electrical connection from main control & preparation of old painted steel surfaces by scrapping and brooming down and cleaning oil/greasey spot by using CTC and filling cavities using suitable fillings compound to achieve smooth surfaces and then applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer to the exposed steel surfaces of 39 TR Chiller AC Plant complete with following accessories : (a) Compressor 12TR Capacity - 9 Nos (b) Condensor - 12 Nos (c) Blower motor / Pump Motor / Chilling Pump Motor (10 HP) - 6 Nos (d) L T Panel Board - 1 No (e) AHU - 2 Nos (f) Hot water pump and hot water generator - 1 No (g) Foundation channel frame
Cutting, drilling and tapping in existing CI/GI pipe line upto 80mm bore for branch connection with and including insertion of new Tee, complete all as specified and as directed.
Dismantling damaged cooling tower line of 34 TR AC plant and providing new 3 metre long, GI, medium grade, tube of 80 mm bore, GI bends - 2 pcs, GI tee - 1 pc, GI reducer socket - 1 pc, GI socket - 2 pcs, GI nipple (6" long) - 4 pcs, alongwith all necessary fittings and all other relevant works for entire completion of the job, complete all as specified and directed.
Dismantling and taking out the water line connections from the make up tank of 20 / 23 TR AC plant and Supply & fixing of new water line connections from make up tank to cooling tower by providing GI pipe 20 mm bore, 18 mtr long, medium grade including necessary GI fittings viz. Elbow - 4 pcs, Union - 2 pcs, Tee - 2 pcs, Reducer - 1 pc, sockets - 4 pcs, nipple (6" long) - 6 pcs and all other relevant works for entire completion of the job & for continuous flow to cooling tower, complete all as specified and as directed.
Supply and fixing three core, PVC sheathed, un-armoured, copper conductor, 1100 volts grade cable of size 6 sqmm including making connection with provision of cable lugs, sockets, glands etc after taking out old one, complete all as specified and directed, Make: Havells/Finolex/RR Cable/Polycab.
S & F gun metal gate valve wth iron wheel head, screwed both ends for 50mm bore pipe including provision of necessary flange, union, nipple after taking out old one, complete all as specified and directed. Make - Zoloto / Kirloskar / Upadhyay
All as per item No. 188 above but 25mm bore pipe.
S & F C.I. butterfly valve, both ends flanged, lever operated of size 50 mm including lever, nuts, bolts, washers & rubber gasket etc, complete all as specified and directed, Make:-Zoloto / Kirloskar / Upadhyay.
S & F C.I. sluice valve, both ends flanged of size 50 mm includingspindal with nuts, bolts, washers & rubber gasket etc, complete all as specified and directed, Make:-Zoloto / Kirloskar / Upadhyay
Taking down damaged insulation of suction line of Chiller Unit, S & F new insulation, providing 2" thick thermocol pipe, joint filling with filling materials, glass wool, wrapping with chicken wire mesh,applying cement mortar for smooth finish and applying weather coat paint, complete all as specified and directed
Dismantling the old un-serviceable panel after taking out carefully all electrical connections and refrigeration lines of the unit by cutting with gas welding set & taking out foundation bolts, nuts and removing from base , complete all as specified and directed.
Supply, Installing, Testing & Commissioning of CPRI approved, cubical LT panel board, Feeder Pillar Box, "Indoor type", Floor mounted of required size to accomodate all of its components, accessories, items, factory fabricated & factory assembled, out of 1.60mm thick CRCA sheet, supporting frame made out MC75 of chanel section of size 75x40x4.8mm (minimum size) , all the steel surfaces (internally as well as externally) shall be duly pre-treated with anti-corrosive coating & finally epoxy powder coated of tint grey-shade (RAL-7032), double door, front & back openable with locking arrangement, the panel shall be provided with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-54, the panel shall have independent housing for each control switch gear & shall be accommodated with & including bus-bars, the panel shall be suitable for 3 Phase, 4 wire system, 50Hz, 415/440 volts grade electric supply, duly provided with multistraded internal wiring with not less than 2.5 sqmm copper conductor wire (with & including copper lugs of suitable sizes), also including making good the damaged/broken portion of foundation/plateform/plinth/blocks with CM 1:3/PCC 1:2:4 as per site requirement and also provided with the following accessories, components, items, complete all as specified and directed.:- (A) BUS BARS AND INTERNAL CONNECTIONS : The bus-bars shall be made up of pure copper conductor, Copper Busbar (4 nos) of size 50 x 5 mm and suitable cross-sectional area to carry 1.5 times current carrying capacity, wires of sizes 1 sq mm - 1 coil, 4 sq mm - 35 m, 16 sq mm - 40 m, sockets of sizes 16 sq mm - 150 pcs, 4 sq mm - 150 pcs, wiring materials including complete electrical devices wiring with interlocking connection with all control accessories and terminal connections in the electrical control panel (B) PROVISION FOR CABLE ENTRY/EXIT : Openings for cable entry/exit with & including cable grlands & copper lugs shall be provided in the bottom of panel for both incoming & out-going cables.
(xxiv) Auxiliary Contact Block (2NO 2NC) - 11 Nos (xxv) MCCB, 4 Pole, 250 A, 36 kA - 01Nos NOTES :- (a) All the live parts and joints shall be insulated with HRFP shrouds conforming to relevant IS. (b) Cost for provision of any other item (s)/ accessories/ components as per manufacturer instructions & as directed by the GE for the functional requirement and entire completion of the work/ item, shall also be deemed to be included in the quoted rate of above item. (c) Suitable openable doors shall be provided for all the operational switch gear & MCCB's and detacthable cover shall be provided on all other accessories. (d) The cost of making connection with provision of copper lugs with the existing cable shall also be deemed to be included in the quoted rate of above item. (e) The design & drawing, name of manufacturer of Panel, including the details & makes of the components, accessories, items of the Panel, shall be got approved by the contractor from the GE, before procurement of the Panel.
Dismantling un-serviceable blower motor after disconnecting all electrical connections and removing from its base and S & F new 3 Phase, Square cage, induction motor (IE2) of capacity 1 HP, 373-456 Volts, 50 Hz with and including pulley, lock nuts, foundation bolts including Lathe job for pulley bush and making electrical connection with cable lugs, sockets, terminal bolts etc, complete all as specified and directed. Model: CM/L7800028518 of Make Bharat Bijlee or equivalent Make of Crompton / Kirloskar / Hindustan Electric Motors / Godrej Lawkim Motors.
Dismantling un-serviceable Condenser Fan Motor after disconnecting all electrical connections and removing from its base and S & F single phase induction motor of capacity 370 W, 240 V, RPM-900 complete all as specified and directed. Model: LM200LK4022 of Make: Godrej or equivalent as approved by the GE.
Supply & Fixing Y-Strainer with filter for liquid line after taking down old unserviceable one from existing location including necessary gas welding with fittings complete all as specified and directed
Disconnection from system, strip opening of refrigerant compressor of capacity 39TR completely and checking of various components with precision instrument to assess the requirement of repairs / replacement, making inventories of repairs required, calibration of microprocessor chips and re-assembling the dismantled compressor with re-fixing the serviceable parts in position after proper cleaning and lubricating etc, replacement of the minor defected parts such as gasket, nut, washer etc. with new parts as required at site, connecting the compressor and making perfectly leak proof after cleaning and testing the compressor on full load, complete all as specified and directed.
Supply & fixing filter dryer for chiller unit / package unit after taking out old one, complete all as specified and directed, Make:- Danfoss/Dry valve or equivalent as approved by the GE.
Dismantling and opening of Y Strainer after disconnection from line and removing nut, bolt etc for overhauling/repairing and cleaning strainer with descleaning agent, also replacement of gaskets, nuts, bolts, washers and re-fixing the same in existing line, complete all as specified and directed.
Supply only empty refrigerant gas cylinder fitted with brass valve, cap complete conforming to IS: 3196 (Part-2), three piece welded, valve conforming to IS: 3224, water capacity of 68 litre, gas capacity of 61 kg, 4 mm wall thickness complete all as specified and directed. Make: JMGCL or equivalent as approved by the GE.
Dismantling & opening of FRP cooling tower after disconnection of all electrical and water line connections, taking out Fan Pulley, Bearing housing with shaft, header, spray nozzle, fill sheet and Repair and Overhauling the same after replacement of bearing housing, pulley assembly, QD Bushing, spray nozzle, fill sheet, oil cup, nuts, bolts, washers and refixing the same for smooth functioning of cooling tower of capacity 34 / 20 / 15 TR all as specified and as directed.
Supply, installation and commissioning of cooling coil suitable for 34 TR capacity AC Plant comprising coil section with multirow coil made of 5/8" x 24 SWG copper tubes and 36 SWG aluminium fins firmly bonded to copper tube and 4 rows deep with header and distributor after dismantling of old unserviceable coil from the existing system by disconnecting all refrigerant pipe lines and electrical connections, valves and re-installation of the new one with necessary copper fittings by gas welding / electric arc welding to match with the existing system, complete all as specified and directed. Note:- Supply and Fixing of various components in the cooling coil will be measured and paid separately here-in-after
Dismantling AHU Panel and its steel structure from base by disconnecting all refrigerant gas lines, electrical lines etc. and Supply and Fixing new panel with steel structure of size for capacity 34 TR AC Plant. Panel shall be made of 22 SWG powder coated outer surface and 22 SWG plain GI sheet for the inner surface with 25 mm sandwiched PUF insulation including vibration absorber, filter media having 90% efficiency down to 10 micron with new fitting, nuts, bolts, washers, screws with foundation concreting, gas welding or electric arc welding, complete all as specified and directed.
Dismantling old unserviceable Blower unit of 34 TR capacity AC Plant, after disconnecting all refrigerant gas lines, electrical lines etc.and taking out unserviceable existing items, Supply and installation of new Blower unit of 34TR capacity with scroll, blower shaft, bearing with housing, runner, pulley, with necessary connected materials viz nuts, bolts, washers, clamps, including gas welding or electric arc welding, complete all as specified and directed.
S & F copper pipe of good quality of size 1/4" with necessary fittings including taking down old unserviceable one from existing location, complete all as specified and directed.Make:- Parasmani/Camipro or equivalent as approved by the GE.
All as per item No. 207 above but size 1/2".
All as per item No. 207 above but size 5/8".
All as per item No. 207 above but size1 1/8"
Supply and fixing angle valve of good quality of size 1/4" x 1/4" for charging refrigerant gas to various capacity compressors complete all as specified and directed. Make: TEK or equivalent as approved by the GE.
Supply and fixing water pressure gauge of 0-10 kg/cm2 with and including brass adaptor, flare nut etc after taking out old one for water line complete all as specified and directed. Make: Fiebig / H.Guru or equivalent as approved by the GE.
Supply only Big Size Rechargeable LED Torch for all AC installations, 80 W Hi-Bright LED, alongwith 4V 3000 mAh rechargeable lead-acid battery, and electric charger for 20-24 hours charging time suitable for power source of AC 220V-240V, 50-60 Hz complete all as specified and directed. Model: KG-6560 of Make: Kennede Gold / Damoda or equivalent as approved by the GE.
Shree Ram Construction
SARKAR ENGINEERING CO.
M/S BIJAY KUMAR SHIVA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .