Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L1 | Accepted-AOC Lowest hence accepted | |
| 2 | L2₹23.1 L+₹38,691.46 (1.70%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L2 | Rejected-AOC Not lowest |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
3 Jun 2020, 6:00 pmClosed
GE GOLCONDA
GE GOLCONDA LANGERHOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA
SPECIAL REPAIR TO ROOF TREATMENT INCLUDING PROVN OF TOILET BLOCK AT 354 FIELD HOSPITAL PROVN OF FLY PROOF DOORS IN BLDG NO 253 255 AND SPL REPAIR FOR REPLACEMENT OF LT OVER HEAD LINES WITH LT UG CABLES FOR OFFICER QTRS UNDER GE GOLCONDA
2020_MES_333002_1
GE/GOL/Token No.35 of 2019-2020
Open Tender
Civil Works
Item Rate
270 days
GE GOLCONDA
Application for tender
DD in favour of GE Golconda
EMD for UE contractors
Enlistment letter
For UE contractors documents meeting enlistment criteria as per NIT
GST registration No
Provident fund No
Electrical license issued by State Govt
7 documents required · 7 mandatory
₹500
GE GOLCONDA
₹44,000
Yes
17 Sept 2020
10 Mar 2020
5 Jun 2020
10 Mar 2020
3 Jun 2020
21 Mar 2020
10 Mar 2020 - 20 Mar 2020
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation,etc or for shafts wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in hard soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point in soils complete all as specified and directed
M&L for Hard core of guage n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed
M&L for plain cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation/mass filling complete all as specified and directed
M&L for Cement concrete cast-in situ (1:2:4) type B1 (using 20mm graded stone aggregate) as in lintels up to 1.5m clear span,cills steps:seimic and other similar bands,plinth courses,string scourses,lacing courses,perapets and railings upto 60 cm in height ,copings,kneerlers,apex stones,bed plates,kerbs not provided water troughs and thelike including wethering,slightly rounded or chamfred angles and throating (the rate include use of farm work and reinforcement shall be measured separately) complete all as specified and directed.
M&L RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in pre-cast cover slabs for manholes incl necessary form work set in CM 1:4 (Reinforcement will be measured & paid separately) complete all as specified and directed.
M&L PCC (1:2:4) type B1 (using 20 mm graded stone aggregated) set in CM 1:4 as in benching to manholes complete all as specified and directed.
M & L Brickwork with sub class 'B' bricks , straight or curved on plan exc 6m mean radious built in cement mortar (1:4) complete all as specified and directed.
M & L Brickwork with sub-class 'B' bricks old size straight or curved on plan to any radius half brick thick built in cement mortar (1:4) complete all as specified and directed.
M&L for Walling of random rubble, coursed, well bonded, bedded and solidly hearted, built in CM 1:6 secunderabad type complete all as specified and directed.
M&L Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for 2nd Class hardwood plain fillets, square or triangular in section,clean swan, secured with nails or brads croos section exc 13 Sqcm but not exc 25 Sqcm complete all as specified and directed.
S&F, 2nd class hard wood, factory made plain framed panelled shutter 35mm thick two panel, with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS 1003 Part-I kiln seasoned and chemically pressure treated complete all as specified and directed.
M&L 2nd class hard wood, factory made, plain framed panelied door shutter(conforming to IS), 30 mm thick (two or three panels) with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces BWR grade (conforming to IS), the size of rail & style as per IS 1003 (Part-I) Kiln seasoned and chemically pressure treated complete all as specified and directed.
S & F 2nd class hard wood, 35mm thick factory made, glazed and skelton shutters sizes of members as specified in SSR(Part-I) clause 8.20(a), open rebated and prepared to receive glass or gauge, edges of framing plain, chamfered or rounded, fitted with cut and miterd beads for securing glass or gauge etc., complete all as specified as directed by Engr-in- charge.
S&F of factory made plain framed panelled shutter two panel in 2nd class HW with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS 1003 Part-I kiln seasoned and chemically pressure treated thickness of shutter 35mm complete all as specified and directed.
S&F for small fittings of 2nd class hardwood such as brackets of any type latch and hinge blocks shapped door and window stops and the like including all necessary labours article n.exc 200 cu.cm each complete all as specified and directed.
S&F PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling fixing in opening etc complete all as specified and directed.
S&F solid PVC Panel Door shutter 30mm thick style consisting of Frame made out of M.S Tube for top & Bottom rails, MS Frame shall be covered with heat moulded, Plain colour PVC’C’ channel having a PVC Sheets strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for Top rail, lock rail bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour 5mm thick PVC sheet fitted in the MS Frame, welded/ sealed to stiles and rail with suitable PVC sheet beading and jointed together with solvent cement all as per manufacture instruction complete all as specified and directed.
S&F MS Barrel tower bolt of size 150mm long stove enamelled black with bright bolt complete all as specified and directed.
S & F 200 mm length of aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 300mm long Mild steel sliding door bolts , plate type stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts & nuts four on bolt plate and two on staple plate complete all as specified and directed.
S & F for Butt hinges, medium weight, cold rolled of size 100 mm complete all as directed.
S & F for Butt hinges, medium weight, cold rolled of size 75 mm complete all as directed.
S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed, type B-21 complete all as specified and directed.
S&F of MS 300mm long ordinary rat tail rod pattern springs including roller plate complete all as specified and directed.
S&F Mild stell pressed handles oval type stove enamelled black of 150mm long complete all as specified and directed.
S & F 150 mm length of extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed.
S&F of Stainless steel wire cloth 0.36mm nominal dia of wire and average width of apreture 1.40mm and fixed with stainless steel wire staple complete all as specified and directed.
S&F of Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 290-0 or Gde E-165 complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
All as per Serial Item No. 32 here-in-before but 6 to 8mm dia bars
All as per Serial Item No. 32 here-in-before but 5 to 10mm dia bars as in stirrups
S&F of steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and directed.
M&L Machine cut kota stone slab flooring 20-25mm thick laid over and including cement screed (1:6) 15mm laid base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with bee wax etc complete all as specified and directed.
M&L 75 mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) in plinth protection/paths etc finished even and smooth w/o using extra cement complete all as specified and directed.
M & L for 75 mm thick, plain Cement concrete 1:4:8 type D-2, (40mm graded aggregate),as in sub base complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surfaces 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in CM 1:4 as in backing coat to receive tile finish complete all as specified and directed.
M&L for non skid ceramic colour tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.06 Sqm but not exc 0.11 sqm in floors set and jointed in neat cement slurry and pointed in coloured cement to match the shade using coloured tiles including 15mm thick Screed bed or bedding layer for laying floor finishes in CM 1:6 complete all as specified and directed.
M & L for Chequered cement concrete tiles 300 mm x 300 mm x 25mm thick,set, jointed and pointed in neat cement slurry in floors, with gery cement and no pigment, laid over and including 15mm thick screed bed or bedding layer in CM 1:6 etc complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with wooden beads or oil putty in square not exc. 0.50 Sqm in each pane complete all as specified and directed.
M&L for preparation of wood and wood based new surfaces of any description not other wise described over 10 cm width or girth and apply one priming coat of pink primer on preparation new surface and two coat of synthehtic enemal paint on pink primer surfaces complete all as specified and directed.
M&L for preparation of old painted wood and wood based surfaces of any description not other wise described over 10 cm width or girth, previously untrtied surface and applying one coat of synthetic enemal paint complete all as specified and directed.
M&L for preparation of steel surfaces and apply two coats of synthetic enamel paint over a coat of red oxide primer, width or girth exc 10cm complete all as specified and directed.
S&F steel water tubing, 'Medium grade' galvanised, with all fittings and fixed comp to walls and ceilings or laid in floors of 15 mm bore complete all as specified and directed.
S&F Rotational moulded polythylene watter storage tanks double layered (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 500 ltrs complete all as specified and directed.
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F Stop valves (angle cock), cast copper alloy, fancy type, chromium plated screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed 15mmbore complete all as specified and directed.
S&F steel water tubing, 'Medium grade' galvanised, with all fittings and fixed comp to walls and ceilings or laid in floors of 20 mm bore complete all as specified and directed.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20 mm bore complete all as specified and directed.
S&F of PVC (SWR) floor trap plain with grating including jointing with solvent cement of dia of outlet 75mm complete all as specified and directed.
S&F of Ball valves high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed to 20mm bore pipe complete all as specified and directed.
Supply and fix PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore complete all as specified and directed.
S & F 110 mm bore PVC (SWR) pipe single socketed,in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F of PVC (SWR) bend any radius of bore 110mm complete all as specified and directed.
S&F PVC (SWR) bends any radius 75mm bore complete all as specified and directed.
S&F of PVC (SWR) bend any radius vent cowl of bore 110mm complete all as specified and directed.
M&L salt glazed stone were drain pipes 150mm dia bore (Grade 'A' pipe) laid in trenches and jointed as specified incl demolition complete all as specified and directed.
M&L salt glazed stone wave gully traps square or rounded mouthed type & fix 150 x 150 mm fixed in cement concrete complete all as specified and directed.
Demolition of brick work or stone masonary, built in cement mortar complete all as specified and directed.
Dismantiling of Stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar, etc complete all as specified and directed.
Taking down chowkats or frames with shutters without taking of shutter from frame area exc 1.5 Sqm but not e.xc 4.00 Sqm each including removing to store complete all as specified and directed.
S & F in repairs 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
M&L Rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surface on wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 5 mm thick rendering in CM 1:3 on ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 10mm thick rendering in CM 1:6 on brick or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed.
Complete removal of existing treatment on walls and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
M&L for preparation of new plastered wall surfaces and apply two coats of cement based paint over a coat of cement primer complete all as specified and directed.
M&L for preparation of wall surfaces and apply three coats of white wash on internal wall surfaces complete all as specified and directed.
M&L for three coat of white wash on new surface of ceilings including preperation complete all as specified and directed.
S&F of PVC (SWR) single T junction equal or unequal with access door of bore 110mm complete all as specified and directed.
Supply and fix PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe in repairs complete all as specified and directed.
S & F Vitreous China squatting pan , "Orrissa" pattern size 580 X 440 mm white with intgrel footrest (excluding flushing cistern & flush pipe complete including provision of cement concrete complete all as specified and directed.
Supply and fix wash hand basin Vitreous china white flat back size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed.
M&L for RCC 1:1.5:3 type A1 using 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L priming plastered roof surfaces with bituminious primer @ 0.3 Kg /sqm as per IS -3384 and providing water proofing treatment by applying mineral finish 3.5 Kg /sqm actatic poly propulene (Advance app torch membrance with fibre glass and finished on top with fiber glassmineral statess torch incistren of thickness 3mm by torch bonding complete over and providing necessary slope using WPC @ 3% or as per manufacture infracture instructions after taking down carefully cement lime plaster of any thickness of roof incl existing tar pelt of any thick ness and preparing the surfaces by cleaning of foreign matter by wire brushing roughing surfaces to receive plastered and scrubbing down with water (IWPC paid seperatly) complete all as specified and directed.
S&F of Plastic waste pipe for Wash hand basin 32mm dia complete all as specified and directed.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with 200 mm thick PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
S & F of tubes light grade of 80 mm bore galvanised with all fitting for cable protection trenches/wall/on pole/ OHT all as specified and directed by EIC.
S & F of tubes light grade of 50 mm bore galvanised with all fitting for cable protection trenches/wall/on pole/ OHT all as specified and directed by EIC.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size
4 x 10 Sqmm
4 x 16 Sqmm
3.5 x 35 Sqmm
3.5x120 Sqmm
Supply and spreading dry river sand in trenches for cables cushioning on top and bottom of cables all as specified. *Note: Punned thickness of sand cushioning shall only measured for the purpose of payment
M&L for brick protection cover of old size bricks common burnt clay building bricks sub class 'B' laid dry and flat abutting each other with width equal to length of brick and gap between adjacent bricks not exceeding 10 mm complete all as directed.
Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32mm x 6mm dia by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 5 connected to earth test point incl necessary earth work excavation PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber provn of RCC cover 40mm thick in 1:2:4 mix type B1 funnel with water pipe GI pipe 15mm dia medium grade as protection pipe GI 40 mm dia for earth strip all as specified. specified in SSR Part II. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
Taking down carefully existing copper/Aluminum point wiring of any description light, fan,sockets,bells etc., complete including fittings such as terminal boxes, switches, sockets, ceiling rose, lamp holders, brackets sketch fittings, pendants, fan regulartors and making good the dis turbed surfaces, walls, floors etc., to match with existing surface, complete all as specified and directed.
M&L Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sqmm multistrand copper conductor cable PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 1.50 sqmm PVC (FRLSH) insulated unsheathed copper conductor single core cable ( green colour) as earth lead in and including non metalic rigid PVC conduit medium grade with appropriate size with all fittings (ISI Marked) suitable for surface type on stone/brick masonary walls, ceilings of roof etc., including in conceled new /old CI/MS sunk box 2 mm thick plastic laminated sheet for housing switches sockets, regulators etc, complete all as specified and directed
All as per item no.96 here-in-before but one exhaust fan point controlled by one, one way switch
All as per item No.96 here-in-before but One 3 pin 5/6 Amps switch socket outlet on same board.
All as per item No. 96 here-in-before but One 3 pin 5/6 Amps switch socket outlet on independent board complete all as spcified and directed.
All as per item No. 96 here-in-before but wiring with 2.5 Sq mm and 1.5 sqmm for earth continuity for 3 pin 15/16 Amps switch socket combination
M&L switch piano flush type single pole one way 5 Amps complete all as spcified and directed.
M&L switch socket combination flush type 5 Amps Multipurpose 2 in 1, 3 pin/2 pin with porcelain base all as specified complete all as spcified and directed.
M&L Switch socket combination 2 in 1 flush type universal 3 pin 5 Amps and 15 Amps complete all as spcified and directed.
M&L lamp holder, PVC/Polycaronate type insulated body with back plate suitable for battern fittings complete all as specified and directed.
S&F Ceiling rose surface 3 phase / PVC / polycarbonate,isolated body bakelite 65 x 50 mm 2/3 terminais complete all as specified and directed.
S&F Electronic ceiling fan regulator Stepped socket type type AC 240 V complete all as specified and directed.
S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 8 Ways, including taking down of existing sheet metal enclosure complete all as specified and directed.
S&F MCB single pole and neutral 32 Amps 240 Volts complete all as specified and directed.
S&F MCB single pole 240 Volts 6 to 32 Amps complete all as specified and directed.
S & F LED tube light fittings 1 x 22 W, 230V, complete with all accessories internally prewired and including LED Tube rod connecting up with twisted flexible PVC copper conductor cable of 23/0.0076 from ceiling rose complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.5 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead complete all as specified and directed.
S&F Steel water tubing, medium grade, galvanised, 25 mm bore with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc., complete all as specified and directed.
S&F gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of 25 mm bore including taking down existing gate valve, complete all as specified and directed.
M & L for laying, jointing, connecting and testing XLPE/PVC insulated and sheathed UG heavy duty wire / strip armoured 1100 v grade solid/multistranded aluminium conductor cable of 2 core 10 sq mm.complete all as specified and directed.
S&F LED Building security lights New generation energy saving & enviromental friendly long life versitile pressure die cast aluminum roadway luminarie with high power LEDS 20 watts as light source and electronic driver bracket made into required shape for fittings complete with MS clamp, nuts and bolts and washsers as required at site of minimum 1.5 mtr long Med grade GI pipe 40 mm dia including painting with one coat of primer and two coat of aluminium paint complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover class HV Type 1 flat with peak size 300x180x40 mm complete all as specified and as directed.
Supply and fixing LED BULB 7 W complete all as specified and directed.
S&F Sheet metal enclosure MCB distribution board double door type including 200 Amps bus-bar single pole and neutral 240V, 4 Ways, including taking down of existing sheet metal enclosure complete all as specifide and directed.
Supply and Fix Exaust fan of size 300 mm sweep,AC, 230 V Turbo force SP complete all as specified and directed.
Supply anfd fix in bracket made out of 32/40GI pipe light grade and bend to shape including clamps, nuts and bolts etc and required electrical connections complete all as specified and directed.
S&F 1100 V grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connections suspended by insulated hangers not more than 1 mtr apart incl 4 mm suspension wire one twin core cable flat or circular stranded conductor of 4 Sqmm complete all as specified and directed by the Engr-in-charge.
Cutting the existing CI pipe line 50/80mm dia (in position) for tapping of 25 mm GI pipe for branch connection incl necessary jointing material comlete all as specified and as directed.
STANDARD AGENCIES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .