true rms clamp meter True Rms Clamp Meter ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERAL FEATURES Type Hand Held Hand Held Display 4 digit Backlit LCD 4 digit Backlit LCD Measurement Type True RMS True RMS count 10000 10000 MEASUREMENT FEATURES Resistance Measurement Range 10 4
10
100
1000 Resistance Measurement Accuracy (+/-) 1.5 0.5
1
1.5
2 Frequency Measurement Range 500 0.5
500 Frequency Measurement Accuracy (+/-) 0.5 0.5
0.3
0.1 AC Current Measurement Range 1000 10
1000 AC Current Measurement Accuracy (+/-) 2 1
2
2.5 1/4 AC Voltage Measurement Range 600 400
600
750
1000 AC Voltage Measurement Accuracy (+/-) 1 1.5
2 DC Current Measurement Range 1000 100
1000 DC Current Measurement Accuracy (+/-) 2 1.5
1 DC Voltage Measurement Range 1000 0.4
4
40
400
1000 DC Voltage Measurement Accuracy (+/-) 1 1
2 Other features
if applicable Inrush Current Measuring Function for DCA & ACA
Good for PWM trouble shooting and in noisy environment measurement
instant continuity Buzzer
Relative zero mode function * GENERIC Jaw Size (Dia in Closed State) 48 * Dimensions (H x W x L) (mm x mm x mm) 250x100x46 * Weight 425 * POWER REQUIREMENTS Power Requirements Battery Operated * Type of Battery Non- Rechargeable (Alkaline) * if rechargeable
then chemistry of the battery NA * if Non-rechargeable
then size of the battery cell 9-V rectangular battery * Number of non- rechargeable the battery/cell 1 * Voltage of rechargeable Battery milliamphere hour 0 * Suitable charger/adaptor provided NA * 2/4 OPERATING CONDITION Minimum Operating Temperature 0 * Maximum Operating Temperature 50 * Operating Humidity (RH) 80 * SAFETY Safety Certification UL
CE
CSA
TUV * Safety Rating CAT III 600 V of IEC 61010 -2-D31 CAT III 600 V of IEC 61010 -2-D31
CAT IV 300 V of IEC 61010 -2-D31 ACCESSORIES Details of the Standard Accessories Supplied with the Equipment Test Lead Set
User Manual
Banana plug K- type Thermocouple
Aligator & carrying case * SERVICE Warranty 1 1
3 TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hrs at a specified maximum temp false * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest false * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH false * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test - * Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters. Consignees and Quantity 3/4 S.No. Consignee Address Quantity Delivery Days 1 Praveen Kumar 486890
CENTRAL STORE
JAYANT COLLIERY 2 30