| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.6 LAccepted-AOC CHOTONILPUR KUCHULPUKUR PAR BURDWAN | 1 | Accepted-AOC Lowest Bidder | |
| 2 | 2₹1.7 L+₹338.35 (0.21%)Rejected-Finance VILL SUKANTANAGAR P O SRIPALLY DIST PURBA BARDHAMAN | PURBA BARDHAMAN | WEST BENGAL | 2 | Rejected-Finance 2nd Lowest Bidder | |
| 3 | 3₹2.1 L+₹48,433.50 (29.4%)Rejected-Finance | 3 | Rejected-Finance 4th Lowest Bidder | |
| 4 | 4₹2.3 L+₹61,706.45 (37.4%)Rejected-Finance 02 NO ICHLABAD SRIPALLY PURBA BARDHAMAN | HOOGHLY | WEST BENGAL | 712134 | 4 | Rejected-Finance 3rd Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
6 Mar 2021, 6:00 pmClosed
BDO , RAINA 1 DEVELOPMENT BLOCK
Shyamsundar, Purba Bardhaman
Erection ofTemporary electrification work including fitting ,fixing and supply of materials at 261 Raina AC on hire basis for WBLAE 2021
2021_ZPHD_329702_1
WB/RAINA-1/BDO/NIT-59
Open Tender
CIVIL WORKS
Item Rate
SHYAMSUNDAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹10,000
Yes
11 Mar 2021
1 Mar 2021
9 Mar 2021
1 Mar 2021
6 Mar 2021
1 Mar 2021
Amount
Hiring charges for S& installation (Temporary) 415V, 62.5 KVA, 50Hz 3ph D.G. set for supply uninterupted power incl. loading at site incl. labour charges with necy. Inter connection of Generator. Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only Generator beyond 4 days per day
Hiring charges for S& installation (Temporary) 440V, 125KVA, 50Hz 3ph D.G. set for supply uninterupted power incl. loading at site including labour charges with necy. Inter connection of Generator.Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only Generator beyond 4 days per day
Hiring charges for S& installation (Temporary) 440V, 35KVA, 50Hz 3ph D.G. set for supply uninterupted power incl. loading at site incl. labour charges with necy. Inter connection of Generator. Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only Generator beyond 4 days per day
Hiring charges for S& installation (Temporary) 440V, 10KVA, 50Hz 3ph D.G. set for supply uninterupted power incl. loading at site incl. labour charges with necy. Inter connection of Generator. Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only Generator beyond 4 days per day
Hiring charges for S& installation (Temporary) 440V, 5KVA, 50Hz 1ph D.G. set for supply uninterupted power incl. loading at site incl. labour charges with necy. Inter connection of Generator. Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only Generator beyond 4 days per day
S& charging of Diesel for smooth operation of D.G. set incl. carrying & storage (oil) from pump to site Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only fuel beyond 4 days per day
Temporary Neutral earthing arrangement for all 3-phase/ 1-ph DG. Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
Providing on hiring basis diff. sizes PVC/ Al/Ar Cable on/above ground/pole to pole fittings to fittings incl. dismantling after programme etc. Rate for hire & labour charges including carriage upto 4 days a) 3.5 core 120 sq.mm. PVC/Al/Ar
b) 3.5 core 95 sq.mm. PVC/Al/Ar
c) 3.5 core 50 sq.mm. PVC/Al/Ar
d) 3.5 core 35 sq.mm. PVC/Al/Ar
e) 4 core 16 sq.mm. PVC/Al/Ar
f) 2 core 10 sq.mm. PVC/Al/Ar
Rate for hire charges only materials beyond 4 days per day a) 3.5 core 120 sq.mm. PVC/Al/Ar
b) 3.5 core 95 sq.mm. PVC/Al/Ar
c) 3.5 core 50 sq.mm. PVC/Al/Ar
d) 3.5 core 35 sq.mm. PVC/Al/Ar
e) 4 core 16 sq.mm. PVC/Al/Ar
f) 2 core 10 sq.mm. PVC/Al/Ar
Providing on hire basis incl. supply / drawing of single core copper wire for metal / sodium light, stall light, Fans,stage light, pelmet screen incl. dismentling as follows:- a) 2 x 6 sq. mm. PVC copper wire Rate for hire & labour charges including carriage upto 4 days
b) 2 x 4 sq. mm. PVC copper wire
c) 2 x 2.5 sq. mm. + 1x1.5 sq.mm . PVC copper wire
Rate for hire charges only materials beyond 4 days per day a) 2 x 6 sq. mm. PVC copper wire
b) 2 x 4 sq. mm. PVC copper wire
c) 2 x 2.5 sq. mm. + 1x1.5 sq.mm . PVC copper wire
Providing on hire basis incl. supply / drawing of single core copper wire for outdoor metal / sodium light, stall light, Fans & plug point incl. dismentling as follows:- a) 2 x 6 sq. mm. PVC single core Al wire Rate for hire & labour charges including carriage upto 4 days
b) 2 x 4 sq. mm. PVC single core Al wire
Rate for hire charges only materials beyond 4 days per day a) 2 x 6 sq. mm. PVC single core Al wire
b) 2 x 4 sq. mm. PVC single core Al wire
Supply & installation on hiring basis (Temporary) Industrial Main panel for DG sets & following switch etc. on suitable angle iron frame including inter connection wiring with socketing earthing attachment etc. & dismentling at the end of Programme etc. a) 250A, 415V,TPN SDFU switch with 3 nos 250A HRC for incommer -1 No b) 500V, 600Amp capacity 4 bar copper busbar chamber made of 16 SWG CRCA sheet compring with 4 nos 300 Amp capacity eletrolytic tinned copper ber suppported on nonhygroscopic insulating chair.-1set c) 250A 415V FP changeover switch - 01 no d) 100A, 415V,TPN SDFU switch with 3 nos 100A HRC for incommer -04 nos e) 63A, 415V,TPN SDFU switch with 3 nos 63A HRC for incommer -04 nos Rate for hire & labour charges including carriage upto 4 days
Supply & installation on hiring basis (Temporary) Industrial Main panel for DG sets & following switch etc. on suitable angle iron frame including inter connection wiring with socketing earthing attachment etc. & dismentling at the end of Programme etc. a) 250A, 415V,TPN SDFU switch with 3 nos 250A HRC for incommer -1 No b) 500V, 600Amp capacity 4 bar copper busbar chamber made of 16 SWG CRCA sheet compring with 4 nos 300 Amp capacity eletrolytic tinned copper ber suppported on nonhygroscopic insulating chair.-1set c) 250A 415V FP changeover switch - 01 no d) 100A, 415V,TPN SDFU switch with 3 nos 100A HRC for incommer -04 nos e) 63A, 415V,TPN SDFU switch with 3 nos 63A HRC for incommer -04 nos Rate for hire charges only materials beyond 4 days per day
S& installation of MCB control panel for the diff. control i.e. fan light stage light etc. of folloing items. a) S/F of 4 way TPN PBDB as incommer 100A FP Isolator & outgoing of 12 nos 32A SPMCB's Rate for hire & labour charges including carriage upto 4 days
b) S/F of (2+8) way SPNBDB's as incommer of 40A DP Isolator & outgoing of 08 nos 10A-16A SPMCB's
S& installation of MCB control panel for the diff. control i.e. fan light stage light etc. of folloing items. a) S/F of 4 way TPN PBDB as incommer 100A FP Isolator & outgoing of 12 nos 32A SPMCB's Rate for hire charges only materials beyond 4 days per day
b) S/F of (2+8) way SPNBDB's as incommer of 40A DP Isolator & outgoing of 08 nos 10A-16A SPMCB's Rate for hire charges only materials beyond 4 days per day
S& installation of 250V 40 watt single tube light fittings incl. 1no 40watt tube lamp at stall & other places etc including inter connection . Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
Supply & fixing of hire basis 48" celing fans including inter connection . Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
Supply & installation of hire basis 18" air circulator fans including inter connection .Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
Supply & installation of hire basis 16" air circulator fans including inter connection .Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
Supply & installation of 12 watt LED including inter connection .Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
Supply & installation of 100 watt BC lamp including inter connection .Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
Supply & installation of 200 watt BC lamp including inter connection . Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
Providing on hire basis 400 watt sodium vapour (SV)/ metal halide light fittings (Flood light) with control gear box incl. connection without poll . Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
Providing on hire basis 400 watt sodium vapour (SV)/ metal halide light fittings with 9mtr pole with control gear box, lamp incl. connection . Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
Providing on hire basis 9 mtr Tower light fittings including flat iron ring suitable for SV/Matal lamp fittings with 6 nos 150 watt LED Flood light with control box & 4 nos 500 watt hallogen light fittings with control box including necessary inter connection. Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
Providing on hire basis charges of 100 watt LED fittings at different places incl. necessary inter connection Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
Providing on hire basis charges of 60 watt LED fittings at different places incl. necessary inter connection Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
Providing on hire basis incl. Supply / instalation charges of 5/15 A plug with switch on casing board with earthing attachment at different places incl. necessary inter connection (Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
Temporary basis distribution wiring in 1.1KV grade 3x1.5 sq.mm single core stranded FR PVC insulated copper wire (App. Make) in 19mm bore ,3mm thick polythene pipe for horizontal & vertical run in wall & ceiling complete with all accessories to light points along with MCB/kit-kat fuse (For Strong Room) etc. as per site requirement Rate for hire & labour charges including carriage upto 4 days
Rate for hire charges only materials beyond 4 days per day
JIBAN JYOTI ELECTRIC
ASHOKE ENTERPRISE
M.J. ELECTRIC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .