| Sl No | Description | Qty | Unit | M/S ATRACON ELECTRICALS L2 | M S ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | A. Repairing of 3.3 KV VCB Switch, 400Amps, Make- Meditron, SL No. 6278 (put zero against this row in rate column) | 1 | Job | - | - |
| 1.01 | Providing and fixing of shunt trip / closing coil | 1 | Set | 2,865 ₹2,865 | 2,765.29 ₹2,765.29 Lowest |
| 1.02 | Providing and fixing of rectifier unit 110V DC | 1 | Set | 9,450 ₹9,450 | 9,348.12 ₹9,348.12 Lowest |
| 1.03 | Providing and fixing of H.T bushing 11KV with fitting and copper rod | 1 | Set | 37,500 ₹37,500 | 37,095.54 ₹37,095.54 Lowest |
| 1.04 | Providing and fixing of digital / numerical ELR AC/DC voltage grade 110V, current capacity 5A (0.5 to 12A or wider range) | 1 | Set | 16,425 ₹16,425 | 16,325.4 ₹16,325.4 Lowest |
| 1.05 | Providing and fixing of P.T fuse 11KV/1 Amp | 2 | No | 3,490 ₹6,980 | 3,382.84 ₹6,765.68 Lowest |
| 1.06 | Providing and fixing of master trip relay 110V AC/DC | 1 | Set | 11,770 ₹11,770 | 11,667.9 ₹11,667.9 Lowest |
| 1.07 | Providing and fixing of Copper Strip | 12 | Kg | 1,700 ₹20,400 | 1,527 ₹18,324 Lowest |
| 2.00 | B.Repairing of 3.3 KV VCB Switch, 400Amps, Make- ESPL, SL No. SGO-1741 (put zero against this row in rate column) | 1 | Job | - | - |
| 2.01 | Providing and fixing of shunt trip / closing coil | 1 | Set | 2,865 ₹2,865 | 2,765.29 ₹2,765.29 Lowest |
Tender Value
Refer Docs
EMD Value
₹4,600
Closing Date
23 Mar 2026, 10:00 amClosed
Project Engineer (EnM), Kathara Colliery
P.E. (EnM), Office of the PO, Kathara Colliery
(A) Repairing of 3.3KV VCB Switch, 400 Amps, Make- meditron, SL. No.6278 for secondary control of 3 MVA, 11KV/3.3KV oil cooled transformer installed at 3 No. substation (B) Repairing of 3.3 KV VCB Switch, 400 Amp, make-ESPL, SL NO. SGO-1741 for contr
2026_CCL_356410_1
KTC/PE/EnM/25-26/122 Date-11.03.2026
Open Tender
Electrical and Maintenance Works
Item Rate
20 days
P.E. (EnM), Office of the PO, Kathara Colliery
As per NIT
5 documents required · 5 mandatory
₹4,600
Yes
28 Mar 2026
12 Mar 2026
23 Mar 2026
12 Mar 2026
23 Mar 2026
12 Mar 2026
12 Mar 2026 - 19 Mar 2026
A. Repairing of 3.3 KV VCB Switch, 400Amps, Make- Meditron, SL No. 6278 (put zero against this row in rate column)
Providing and fixing of shunt trip / closing coil
Providing and fixing of rectifier unit 110V DC
Providing and fixing of H.T bushing 11KV with fitting and copper rod
Providing and fixing of digital / numerical ELR AC/DC voltage grade 110V, current capacity 5A (0.5 to 12A or wider range)
Providing and fixing of P.T fuse 11KV/1 Amp
Providing and fixing of master trip relay 110V AC/DC
Providing and fixing of Copper Strip
B.Repairing of 3.3 KV VCB Switch, 400Amps, Make- ESPL, SL No. SGO-1741 (put zero against this row in rate column)
Providing and fixing of shunt trip / closing coil
Providing and fixing of rectifier unit 110V DC
Providing and fixing of H.T bushing 11KV with fitting and copper rod
Providing and fixing of digital / numerical ELR AC/DC voltage grade 110V, current capacity 5A (0.5 to 12A or wider range)
Providing and fixing of P.T fuse 11KV/1 Amp
Providing and fixing of master trip relay 110V AC/DC
Providing and fixing of Copper Strip
C. Repairing of 3.3 KV VCB Switch, 400Amps, MakeESPL, SL No. SGO-1743 (put zero against this row in rate column)
Providing and fixing of shunt trip / closing coil
Providing and fixing of rectifier unit 110V DC
Providing and fixing of H.T bushing 11KV with fitting and copper rod
Providing and fixing of digital / numerical ELR AC/DC voltage grade 110V, current capacity 5A (0.5 to 12A or wider range)
Providing and fixing of P.T fuse 11KV/1 Amp
Providing and fixing of master trip relay 110V AC/DC
Providing and fixing of Copper Strip
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.98 MB
BOQ_369259.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .