| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹53.8 L+₹7.3 L (15.6%)Rejected-Finance MB NO 180 MG ROAD JUNGLIGHAT PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹56.2 L+₹9.6 L (20.7%)Rejected-Finance SCHOOL LINE NEAR MINNIEBAY JUNCTION SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹57.2 L+₹10.7 L (23.0%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Not Being L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical As per firm request ltr dt 13.11.23 |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
13 Nov 2023, 6:00 pmClosed
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744103
REPAIR AND MAINT OF INTERNAL ELECTRIC SUPPLY WITH FITTING FIXTURE AT OTM ACCN AND LOW VOLTAGE UG CABLE JOINTING KITS AND OTHER CONNECTED WORKS UNDER AGE E/M-I AT GE MNNIE BAY
2023_MES_623553_1
8298/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Minniebay Port Blair
As per tender documents
10 documents required · 10 mandatory
₹500
GE Minniebay
₹89,000
Yes
19 Dec 2023
16 Oct 2023
15 Nov 2023
17 Oct 2023
13 Nov 2023
31 Oct 2023
Amount
Taking down carefully aluminum/copper point wiring (light fan socket or power) complete with fitting such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCB'S, Main switch from control board and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified and directed by Engineer-in-Charge.
M&L for point wiring with two run of PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm (FRLSH), PVC conduit heavy duty/PVC casing caping and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge GI sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable (FRLSH) as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge. Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment. (c) The decision of wiring on concealed/ on surface portion with rigid PVC conduit medium grade/PVC casing caping shall be provided as per site requirement and contractor shall consider this factor while quoting and no claim shall be entertained later. (d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment (e) The conduit wiring shall be carried out in ceiling portion invariably.
All as per item No.2.00 above but for one light point controlled by 2 Nos two way switches.
All as per item No.2.00 above but for one 3 pin 5A socket outlet independent board.
All as per item No.2.00 above but for one 5A socket outlet on the same board
All as per item No.2.00 above but for one 5A socket outlet below the board.
All as per item No.2.00 above but for 15/16 Amps socket out let independent with 2.5sqmm copper conductor complete all as specified and as directed.
S&F for switch piano polycarbonate body flush button single pole two way 6 amps, 230 volts complete all as specified and as directed.
S&F for switch piano polycarbonate body type single pole one way 5/6 Amp, 230 volts complete all as specified and as directed.
S&F for socket combination Polycarbonate body 2 in 1, 3 pin, 6 Amp and 16 Amp flush type all as specified and directed.
S&F for Switch socket combination Polycarbonate body, 5 pin, 6 Amp flush type all as specified and directed.
S&F for ceiling rose Polycarbonate body surface bakelite 3 terminals, 230 volts complete all as specified and as directed. Note for item No 8 to 12 : The quoted rate inclusive for the following :-.(a) The material shall be ISI marked. In case of non-availability, the certificate for the same to be submitted from the repective manufacturer. (b) Test certificates to be submitted before commencement of work/ claiming for payment.(c) Warranty certificate for minimum 2 years to be submitted from OEM.
M&L for Modular point wiring with two run of PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm (FRLSH), PVC conduit heavy duty/PVC casing caping and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge GI sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable (FRLSH) as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge. Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment. (c) The decision of wiring on concealed/ on surface portion with rigid PVC conduit medium grade/PVC casing caping shall be provided as per site requirement and contractor shall consider this factor while quoting and no claim shall be entertained later. (d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment (e) The conduit wiring shall be carried out in ceiling portion invariably.
All as per serial item No.13.00 above but for one 3 pin module socket out let 5/6 Amps on same board.
All as per serial item No.13.00 above but for one module socket out let 5/6 Amps on Independent board.
All as per serial item No.13.00 above but for one module socket out let 5/6 Amps on below the board.
All as per serial item No.13.00 above but for 15/16 Amps socket out let independent with 4 sqmm copper conductor complete all as specified and as directed.
S&F Modular switch 1 way 6 Amps, 1 module complete all as specified and as directed
S&F for Modular switch 1 way 16 Amps, 1 module complete all as specified and asvdirected.
S&F for Socket, 6 Amps - 2/3 pin combined 2 module complete all as specified and as directed.
M & L for Socket, 16 Amps - 2/3 pin combined 2 module complete all as specified and as directed. Note for item No 18 to 21: The quoted rate inclusive for the following :-. (a) The material shall be ISI marked. In case of non-availability, the certificate for the same to be submitted from manufacturer (b) Test certificates to be submitted before commencement of work/ claiming for payment. (c) Warranty certificate for minimum 2 years to be submitted from OEM.
M & L for replacement of existing old unserviceable submain wiring with four single core PVC insulated unsheathed multistranded FRLSH copper conductor cable of size 10 sqmm and one single core PVC insulated unsheathed multistranded FRLSH copper conductor cable green colour of size 10 Sqmm as earth lead in and including concealed/surface wiring with PVC conduit/PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification all as required at site or directed.
M & L for replacement of existing old u/s submain wiring with two single core PVC insulated unsheathed multistranded FRLSH copper conductor cable of size 4 sqmm and one single core PVC insulated unsheathed multistranded FRLSH copper conductor cable green colour of size 4 Sqmm as earth lead in and including concealed with PVC conduit/PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification all as required at site or directed.
M & L for replacement of existing old u/s submain wiring with two single core PVC insulated unsheathed multistranded FRLSH copper conductor cable of size 6 sqmm and one single core PVC insulated unsheathed multistranded FRLSH copper conductor cable green colour of size 6 Sqmm as earth lead in and including concealedwith PVC conduit/PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. Note for items No 22 & 24: The quoted rate include cost for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment. (c)The decision of wiring on concealed/ on surface portion with rigid PVC conduit medium grade/PVC casing caping shall be provided as per site requirement and contractor shall consider this factor while quoting and no claim shall be entertained later. (d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
Supply and fixing in replacement existing unserviceable tube light fitting with LED 18watt inverter batten type fitting 4 feet long aluminium extruded housing, charging time 10-12 Hrs with 04 Hrs backup,IP-20 ,rated voltage 230 V, 50 hz, system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt,CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
Supply and fixing in replacement of existing old unserviceable tube light fitting with energy saving decorative batten type fitting with LED tube rod 20 watt energy efficient tube light fittings LED complete with 4 feet long channel type made out of CRCA sheet powder coated complete with housing with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fittings ( fittings shall be fitted on two plastic square/round block. Note power factor should not be less than 0.90.
Supply and fixing in replacement of existing old unserviceable luminaire with LED luminaire 600 mm x 600 mm, 40 watt, 220 V, AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size complete all as specified and as directed.
Supply and fixing in replacement of existing old unserviceable luminaire with LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size complete all as specified and as directed.
Supply and fixing in replacement of existing old unserviceable luminaire with round shape 15 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size complete all as specified and as directed.
Supply and fixing in replacement of existing old unserviceable luminaire with LED luminaire 3 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size complete all as specified and as directed.
Supply and fixing in replacement of existing old unserviceable foot light with LED foot light 3 watt, 220 V AC recessed type complete all as specified and as directed.
Supply and fixing in replacement of existing old unserviceable strip light with LED strip light 5 mtr with driver complete all as specified and as directed.
Supply and fixing in replacement of existing old unserviceable mirror light fittings with sleek energy efficient decorative LED mirror light 10 watts, 2 feet with diffuser complete with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceilling rose/PVC connector to light fittings ( fittings shall be fitted on two plastic square/round block. Note for item No 25 to 33 : (i) Driver efficiency more than 85% ( Constant current driver) (ii) Non isolated type driver (iii) THD less than 20% (iv) LED driver current less than 60 mA (v) Efficiency of LED Chip more than 130 lm/watt (vi) Efficiency of LED Fixture 100 lm/watt (vii) Surge protection 2.5 KV & above as per IEC standard (viii) working humidity 95%RH (ix) Life 50000 Hrs at 70% lumens (x) power factor should not be less than 0.90. (xi) CRI more than 80 (xii) Working temp -10 degree to 50 degree C (xiii) Heat Sink extruded aluminum (xiv) junction temperature 85 degree C (xv) Body of fitting Extruded Aluminum (xvi) impact code Min IK 03 or more ( xvii) LM79 report from thir party (instead of company in house lab) NABL/UL accredited lab (xviii) LM 80 report from LED manufacturer (xix) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixture (xx) IP-20 .(xxi) Test certificates to be submitted before commencement of work/ claiming for payment .(xxii) Warranty certificate for minimum 2 years to be submitted from OEM.
M&L for replacement of existing old u/s light fitting with LED bldg security light fitting 24 watt 230V AC outdoor type pressure die cast housing with epoxy powder coated, poly carbonate cover with individual LED lenses with IP 65 protection complete all specified and as directed.
S&F LED Lamp 230 volts,50 Hz,inverter LED 12 watt ,lumen 1200 lm, Charging time 8 to 10 Hours, backup time 04 Hrs, operating temperature -10 to 50 degree celcius,back time 04 Hours, complete all as specififed and direccted by Engineer-in-Charge.
M & L for replacement LED lamp 12 watt , 230 volts retrofit typecomplete all as specififed and direccted by Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25m deep below normal ground level )with top edge of the plate not less than 1.5m below normal ground level connecting with galvanized iron GI earth strip 32 x 6mm by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 20mm dia for protection of GI earth strip upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion. NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing.
Supply & Fix in replacement sheet metal enclosure with SPN MCB DB's 4 way (grouted in walls) double door type IP-43 Protection, Isolated Neutral,Door earthing, cement spill protector complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge. Note :Outgoing MCB will be measured separately.
Supply & Fix in replacement sheet metal enclosure with SPN MCB DB's 8 way ( grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
Supply & Fix in replacement sheet metal enclosure with SPN MCB DB's 12 way ( grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
Supply & Fix in replacement sheet metal enclosure with TPN MCB DB's 4 way ( grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
S&F as in repair of MCCB DB VTPN 4 way IP-43 made of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail ,415 Volts with double door with MCCB incomer and MCB outgoing and fixing of cable with suitable size of lugs complete all as specified and as directed by Engr-in-Charge. Note for item No 39 to 42 : MCCB and MCB will measured and paid separately
Supply and fix in replacement of existing old u/s MCB TPN with MCB TPN C curve, 415 volts any rating from 16 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and as directed by Engr-in-Charge.
Supply and fix in replacement of existing old u/s MCB TPN with MCB TPN C curve, 415 volts any rating from 40 to 100 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and as directed by Engr-in-Charge.
Supply and fix in replacement of existing old u/s MCB SPN with MCB SPN C curve ,240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of unserviceable MCCB 63 Amps, thermal adjustable, current carrying capacity 16 KA , AC 415 Volts three pole complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections all as directed by Engineer-in-charge.
M&L for replacement of unserviceable MCCB 100 Amps, thermal adjustable, current carrying capacity 16 KA , AC 415 Volts three pole complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections all as directed by Engineer-in-charge.
Supply and fix in replacement MCB single pole 240 volts, 'C' curve of rating 6 to 32 amps, with rupturing capacity 10 KA, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing sheet metal enclosure single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed by Engr-in-Charge.
Supply and fixing sheet metal enclosure triple pole and earth with a three pin and earth plug and socket 32 A 415V complete with one triple pole MCB of capacity 32 A complete all as specified and directed by Engr-in-Charge.
Supply and fixing PVC Surface box 3 module complete all as specified and as directed by Engr-in-Charge.
S&F PVC tape of size 25 m long, 25mm width and 0.125 mm thickness complete all as specified and as directed by Engr-in-Charge.
S&F PVC tape of size 20 m long, 25mm width and 0.125 mm thickness complete all as specified and as directed by Engr-in-Charge.
Repair, maint and making the continuity of supply after rectifying the defects of the electrical items such as switches, replacement of fuse wires, distribution boards, MCB (light/power), lamp holders (bracket/ pandents/ batten), bell/buzzer, push button, ceiling rose, capacitors and other similar electrical items/fittings etc. including providioning of small pieces of electrical wire if required of size 1.5 sqmm to 2.5 sqmm single core and length not exceding 0.50m complete all as specified and directed by Engineer-in-Charge. Note :- (i) any accessories found unserviceable that shall be paid as supply only under respective items of this Sch 'A' . (ii) One job only will be considered for each bldg/Qtr per day irrespective of the No of points made serviceable.(iii) The area for attending the complaints are Minnie Bay area (iii) Each complaint attended/rectified shall be measured as one job. (iv) The contractor shall depute necessary man power on daily basis for rectifying the jobs including sundays and holidays.
Supply only for carrying out repairs under item No.54 above with switch piano polycarbonate body type single pole one way 5/6 Amp, 230 volts complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with switch piano polycarbonate body type single pole one way 16 Amp, 230 volts complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with switch socket combination Polycarbonate body 2 in 1,3 pin, 6 Amp and 16 Amp flush type complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with switch socket combination Polycarbonate body 5 pin, 6 Amp flush type complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with socket outlet Polycarbonate body 2 in 1, 3 pin 16 Amp flush type complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with for carrying out repairs under item No.54 above with socket outlet Polycarbonate body , 5 pin 6 Amp flush type complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with bell push with bell push polycarbonate body type 5/6 Amp, 230 volts complete all as specified and as directed by Engr-in-Charge. '
Supply only for carrying out repairs under item No.54 above with bell electric heavy duty Ding Dong type 230 volts single pole complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with ceiling rose Polycarbonate body surface bakelite 2 to 3 terminals, 230 volts complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with modular switch 1 way 6A, 1 module complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with in repair modular switch 1 way 16A, 1 module complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with in repair Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with in repair Socket, 16A - 2/3 pin combined 2 module complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with LED Driver 40 Watt, AC 220-240V, 50HZ suitable for LED ceiling light 40W complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with LED Driver 12/15 Watt, AC 220-240V, 50HZ suitable for LED ceiling light 12/15W complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with lamp holder batten type polycarbonate body with back plate for batten fitting complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm ,cut to size all as required at site complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 2.5 sqmm , cut to size all as required complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 4.0 sqmm , cut to size all as required at site complete all as specified and as directed by Engr-in-Charge.
Supply only for carrying out repairs under item No.54 above with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 6.0 sqmm , cut to size all as required at site complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of old unserviceable cable of size 6 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wire complete all as specified and as directed by Engr-in-Charge.
All as per serial item No. 76.00 above but for service cable of size 10 sqmm,complete all as specified and as directed by Engr-in-Charge. Note for Serial item No.55 to 77: The work covers various areas under the AOR of AGE E/M-I,Minnie Bay. The Contractor shall depute manpower on daily basis round the clock for attending and rectifying the jobs in time. If any breakdowns/complaints simultaneously occured in any areas shall be attended simultaneously by deputing additional manpower/T&P for rectification of defects.The rate quoted deemed to be included for the same. Recovery for non attending of any type rectification/complaint/breakdowns shall be at the rate of Rs 2500 per day irrespective nature of complaint/defect.
Suppy and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT UG cables, XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade including taking unserviceable one complete all as specified and as directed by Engineer-in-Charge for the following size :- Note: (i) The rates shall be inclusive of Cable lugs at both ends of cable and end termination kits will be measured and paid seperately.(ii) Earthwork required shall be measured and paid seperately.(iii) Joint kit if required shall be measured and paid seperately.(iv) Insulation Resistance value of cable shall be recorded before and after laying of cable.
4 Core 6 Sqmm
4 Core 10 Sqmm
4 Core 16 Sqmm
3.5 Core 25 Sqmm
3.5 Core 35 Sqmm
3.5 Core 50 Sqmm
3.5 Core 70 Sqmm
3.5 Core 95 Sqmm
3.5 Core 120 Sqmm
3.5 Core 185 Sqmm
3.5 Core 240 Sqmm
3.5 Core 300 Sqmm
3.5 Core 400 Sqmm
Relaying of serviciable power cable of XLPE / PVC insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade along with DWC pipe laid in trenches / duct with saddling / on pole / through DWC pipe including all necessary fixing arrangement such as lugs and end termination etc of size 10 Sqmm to 35 Sq mm 3.5/4 Core complete all as specified and as directed by Engineer-in-Charge.
Relaying of serviciable power cable of XLPE / PVC insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade along with DWC pipe laid in trenches / duct with shaddling / on pole including all necessary fixing arrangement such as lugs and end termination etc of size 50 Sqmm 3.5 core to 95 Sq mm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
Relaying of serviciable power cable of XLPE / PVC insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade along with DWC pipe laid in trenches / duct with shaddling / on pole including all necessary fixing arrangement such as lugs and end termination etc of size 120 Sqmm 3.5 core to 240 Sq mm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
Relaying of serviciable power cable of XLPE / PVC insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade along with DWC pipe laid in trenches / duct with shaddling / on pole including all necessary fixing arrangement such as lugs and end termination etc of size 300 Sqmm 3.5 core to 630 Sq mm 3.5 core complete all as specified and as directed by Engineer-in-Charge. Note For Item No. 79 to 82: (i) Excavation earth work, returning and refilling shall be paid under quoted rate. (ii) M&L for DWC pipe and XLPE cable, joints against defective shall be measured and paid seperately under relevant item (iii) Quoted rate inclusive of taking out and relaying of cable and serviceable portion of DWC pipe (iv) Cable joint required shall be measured and paid seperately (v) Cost of taking down of existing XLPE cable along with DWC pipe shall deemed to be included in this quoted rate.
Supply & Laying in replacement of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm, polythylene confirming to IS 16205 part-24 including coupler & Bend with smooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge.
Supply & Laying in replacement of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 63 mm, polythylene confirming to IS 16205 part-24 including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge.
Supply & Laying in replacement of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 77 mm, polythylene confirming to IS 16205 part-24 including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge.
Supply & Laying in replacement of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 120 mm polythylene confirming to IS 16205 part-24 including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge.
Supply and laying in repair GI pipe of light grade 40 mm dia all fitting fixture for fixing with wall / road crossing etc. complete all as specified and as directed by Engineer-in-Charge. Note: (i) Road cutting / excavation work shall be measured and paid separately.
Supply and laying in repair GI pipe of light grade 50 mm dia all fitting fixture for fixing with wall / road crossing etc. complete all as specified and as directed by Engineer-in-Charge. Note: (i) Road cutting / excavation work shall be measured and paid separately.
Supply and laying in repair GI pipe of light grade 63 mm dia all fitting fixture for fixing with wall / road crossing etc.complete all as specified and as directed by Engineer-in-Charge
Supply and laying in repair GI pipe of light grade 80 mm dia incluiding all fitting fixture for fixing with wall / road crossing complete all as specified and as directed by Engineer-in-Charge
Excavation in trenches any type of soil (soft/loose/hard/dense) not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, pipe, laying of cable etc not exc 10 Sqmtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and as directed by Engineer-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and as directed by Engineer-in -charge.
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point all as specified and as directed by Engineer-in -charge.
M & L for Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C2 matching with the surroundings complete all as specified and directed by Engineer-in-Charge.
Material and labour for fault finding of LT UG Cable by fault locator machine including excavation, returning refilling after rectification of fault with fixing of Straight through joint kit, extra UG Cable and DWC (Double Wall corrugated) HDPE pipe as per site requirement complete all as specified and as directed by Engineer-in -charge. Note:- Necessary LT XLPE UG Cable, Straight through joint kit, excavation work and DWC (Double Wall corrugated) HDPE pipe measured and paid separately under this quoted rate.
S & F as in repairs for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5 core complete all as specified and as directed by Engineer-in -charge.
S & F as in repairs for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm 3.5 core complete all as specified and as directed by Engineer-in -charge.
S & F as in repairs for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm 3.5 core complete all as specified and as directed by Engineer-in -charge.
S & F as in repairs for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 150 to 185 Sqmm 3.5 Core complete all as specified and as directed by Engineer-in -charge.
S & F as in repairs for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm 3.5 Core complete all as specified and as directed by Engineer-in -charge.
S & F as in repairs for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 400 to 500 Sqmm 3.5 Core complete all as specified and as directed by Engineer-in -charge.
S & F as in repairs for cable jointing kit for 1100Volt grade cable for indoor / outdoor end termination joint kit, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5 core complete all as specified and as directed by Engineer-in -charge.
S & F as in repairs for cable jointing kit for 1100Volt grade cable for indoor / outdoor end termination joint kit, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm 3.5 core complete all as specified and as directed by Engineer-in -charge.
S & F as in repairs for cable jointing kit for 1100Volt grade cable for indoor / outdoor end termination joint kit, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm 3.5 core complete all as specified and as directed by Engineer-in -charge.
S & F as in repairs for cable jointing kit for 1100Volt grade cable for indoor / outdoor end termination joint kit, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 150 to 185 Sqmm 3.5 Corecomplete all as specified and as directed by Engineer-in -charge.
S & F as in repairs for cable jointing kit for 1100Volt grade cable for indoor / outdoor end termination joint kit, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm 3.5 Core complete all as specified and as directed by Engineer-in -charge.
S & F as in repairs for cable jointing kit for 1100Volt grade cable for indoor / outdoor end termination joint kit, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 400 to 500 Sqmm 3.5 Core complete all as specified and as directed by Engineer-in -charge.
Taking down and rerouting / realigning the serviciable Power Cable on wall /cable duct of size 16 to 50 Sqmm 3.5/4 core with saddling, aluminium patti with requard size of screw inside cable duct / on wall complete all as specified and as directed by Engineer in Charge.
Taking down and rerouting / realigning the serviciable Power Cable on wall /cable duct of size 70 to 185 Sqmm 3.5 core with saddling, aluminium patti with requard size of screw inside cable duct / on wall complete all as specified and as directed by Engineer in Charge.
Supply and fix in replacement for aluminium cable lugs for fixing of armoured cables in panels complete all as specified and as directed by Engineer-in-Charge for the following sizes of cables complete all as specified and directed :-
Supply and fix in replacement of Cable gland of LT UG cables in panels for complete all as specified and as directed by Engineer-in-Charge and the following sizes of LT UG cables :-
Demolition of cement Concrete (Unreinforrced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer in Charge.
Material and labour for Plain Cement Concrete in foundations filling and mass concrete of type B2 grade with using 40 mm aggregate (1:2:4) complete all as specified and directed by Engineer in Charge.
Material and labour PCC (1:3:6) type C-1 (using 20 mm graded broken stone aggregate) as in coping/collar of poles including necessary form work complete all as specified
Supply & fixing in repair IP 65 / 66 thermoplastic-polycarbonate cable junction box of size 205X255X112 with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of GI calmp of required size / self drill screw, with 32 Amp four way connector and one no of MCB SP 6 Amp complete all as specified and as directed by Engineer-in -charge
Supply & fixing in repair IP 65 / 66 thermoplastic-polycarbonate cable junction box of size 155X210X92 with terminal suitable for 10 to 16 Sqmm ,which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of required size / self drill screw and four way 32 Amp Connector and 01 No of MCB SP 6 Amp complete all as specified and as directed by Engineer-in -charge
Supply & fixing in repair IP 65 / 66 thermoplastic-polycarbonate cable junction box of size 130X180X77 with terminal suitable for 4 to 10 Sqmm which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of required size / self drill screw, four way connector and 01 No MCB SP 6 Amp Connector complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair service wire aluminium conductor Weather Proof 06 Sqmm two core complete all as specified and as directed by Engineer-in -charge.
Supply and fixing in repair service wire aluminium conductor Weather Proof 10 Sqmm two core complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair LT rubber insulation tape 25 Cm width 2.5m long fixing of connection make water proof outside the Electrical equipments and also fixing the underground cable where crack arises outside complete all as specified and as directed by Engineer-in -charge.
Material and labour for cutting vegetation and surface dressing not exceeding 15 cm deep including site clearance and removing the materials to a distance not-exc 60 mtr complete all as specified and directed by Engineer-in -charge.
Kathir Marketing Services
A. R. ELECTRICALS
Sree Tirumala Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .