Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.6 LAccepted-AOC 5 5 313A S D LAYOUT TIRUPATHI ANDHRA PRADESH | TIRUPATHI | ANDHRA PRADESH | 1 | Accepted-AOC Lowest rate is accept | |
| 2 | Rejected-Technical | - | Rejected-Technical highest bid |
| Sl No | Description | Qty | Unit | JAYARAJ K L2 | M/s Ujwala Infratech (India) Pvt Ltd L1 |
|---|---|---|---|---|---|
| 1.00 | Supply and delivery of DI D/F Gate sluice valves (soft seated) resilient seated soft sealing Gate Valves(Sluice Valves) with body Bonnet of Ductile cast iron ofGrade GGG 40 or equivalent grade,Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 ORing protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 4846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application withpressure rating PN 10/16 -100mm sluice valve | 1 | 1.00 No (One Number) | 16,128.75 ₹16,128.75 | 14,025 ₹14,025 Lowest |
| 2.00 | 150mm Sluice valve | 1 | 1.00 No (One Number) | 25,403.5 ₹25,403.5 | 22,090 ₹22,090 Lowest |
| 3.00 | supply and delivery of DI D/F Diaphragm type own medium controlled Altitude Control and Flow Control Valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.”- 100mm Flow control valve | 2 | 1.00 No (One Number) | 1,80,147.5 ₹3,60,295 | 1,56,650 ₹3,13,300 Lowest |
| 4.00 | 150mm Flow control valve | 2 | 1.00 No (One Number) | 2,62,957.85 ₹5,25,915.7 | 2,28,659 ₹4,57,318 Lowest |
| 5.00 | Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter.The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. -100mm Electromagnetic Flow meter | 2 | 1.00 No (One Number) | 1,20,011.7 ₹2,40,023.4 | 1,04,358 ₹2,08,716 Lowest |
| 6.00 | 150mm Electromagnetic Flow meter | 2 | 1.00 No (One Number) | 1,40,530 ₹2,81,060 | 1,22,200 ₹2,44,400 Lowest |
Tender Value
₹15 L
EMD Value
₹15,000
Closing Date
13 Oct 2025, 3:00 pmClosed
EXECUTIVE OFFICER, GINGEE TOWN PANCHAYAT
EXECUTIVE OFFICER, GINGEE TOWN PANCHAYAT
15th finance tied 2025-26 2nd instalment Supply and Fixing of 3 Nos Flow Control valve and Electromagnetic Flow Meter at OHT in Gingee Town Panchayat
2025_DTP_612953_1
121/2025/A1
Open Tender
Machinery and Machining Tools
Supply
180 days
GINGEE TOWN PANCHAYAT
As per tender rules
1 document required · 1 mandatory
₹6,750
Yes
₹15,000
7 Jan 2026
10 Oct 2025
13 Oct 2025
10 Oct 2025
13 Oct 2025
10 Oct 2025
10 Oct 2025 - 13 Oct 2025
Amount
Supply and delivery of DI D/F Gate sluice valves (soft seated) resilient seated soft sealing Gate Valves(Sluice Valves) with body Bonnet of Ductile cast iron ofGrade GGG 40 or equivalent grade,Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 ORing protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 4846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application withpressure rating PN 10/16 -100mm sluice valve
150mm Sluice valve
supply and delivery of DI D/F Diaphragm type own medium controlled Altitude Control and Flow Control Valve with cast body of ductile iron grade GGG-40 or equivalent grade or as per IS 3896-Part-2-1985 customized control cylinder for linear control behaviour or equivalent, performed diaphragm and pull out safe profile sealing ring of EPDM, threaded inserts (CORFIX - to prevent the coating from coming off in the connections area as well as corrosion and incrustations in the control circuit) or equivalent. Flange connection dimensions according to EN 1092, Part 2/ ISO 7005[DIN]/ IS 1538, all parts (Epoxy coating, and diaphragm) in contact with medium are as per KTW and DVGW certified (harmless)/WRAS & NSF approved. The EPDM rubber & Epoxy coating (EP-P) should be approved by W270.(EP-P)/ WRAS & NSF.”- 100mm Flow control valve
150mm Flow control valve
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter.The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. -100mm Electromagnetic Flow meter
150mm Electromagnetic Flow meter
JAYARAJ K (BID ID -1486072)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_732425.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .