Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.7 LAccepted-AOC | ₹16.7 L | 1 | Accepted-AOC Awarded |
| 2 | 2₹17.0 LRejected-AOC | ₹17.0 L | 2 | Rejected-AOC Not Awarded |
| 3 | 3₹17.0 LRejected-AOC | ₹17.0 L | 3 | Rejected-AOC Not Awarded |
Tender Value
₹17.0 L
EMD Value
₹18,000
Closing Date
24 Apr 2019, 5:00 pmClosed
S.E., E.T.C., Bareilly
Superintending Engineer Hydel Campus, Near L.I.C. Office Rampur Garden, Bareilly
Annual Routine/Breakdown Maintenance of various 220KV and 132KV Transmission Lines under E.T.D., Budaun alongwith other associated Works during the Period of 1 Year w.e.f. 01.05.2019 to 30.04.2020
2019_UPTCL_343980_1
E-Tender No. 142 / W / ETC(B) / 2018 - 19
Open Tender
Electrical Works
365 days
Budaun
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
A/c No 10897666087 IFSC SBIN0000615 S.B.I. Bly
₹18,000
25 Sept 2020
18 Apr 2019
25 Apr 2019
18 Apr 2019
24 Apr 2019
18 Apr 2019
18 Apr 2019 - 24 Apr 2019
Amount
Annual Routine / Breakdown Maintenance of Following 220KV & 132KV Transmission Lines under E.T.D., Budaun alongwith other associated Works during the Period of 1 Year w.e.f. 01.05.2019 to 30.04.2020, with all due Care of Safety & Precautions, with all Cost of Men, Misc. Consumables, T&Ps etc. Required for Satisfactory Completion of the Work as per Technical Specifications & Direction of the Supervising Engineer : (1) 220 KV D.C. Roza - Budaun Line (2) 220 KV S.C. C.B. Ganj - Budaun Line (3) 132 KV S.C. Budaun - Bisauli Line (4) 132 KV S.C. Budaun - Bilsi Line (5) 132 KV S.C. Budaun - Usawan Line (6) 132 KV S.C. Budaun - Ujahni Line on D.C. Towers (7) 132 KV S.C. Bisauli - Chandausi Line (8) LILO of 132 KV Chandausi - Bahjoi Ckt. I at 132KV Sub Station Sahaswan (9) 132 KV D.C. C.B. Ganj - Aonla Line (10) 132KV D.C. Aonla - IFFCO Line (A) Normal Maintenance Work on above Transmission Lines (Work without Shut Down) : (1) Replacement of Tower Part in Place of Missing ones after Fabrication of Tower Parts as per Sample from ‘Off’ sizes G.I. Angles to be Provided by the Department as per Requirement by due Cutting, Drilling etc. and then, Fixing the same at Required Places at different Tower Locations of 220KV / 132KV Transmission Lines with Proper Tightening & Chamfering etc. as per Technical Specification including Transportation of Tower Parts from Storage Place to Line Site and Back the Unutilized Materials to Respective Stores.
(2) Providing & Fixing of Number Plate (as per Technical Specifications / Sample) in Place of Missing ones at different Tower Locations of 220KV / 132KV Transmission Lines with Proper Tightening including Cost of Number Plate.
(3) Providing & Fixing of Danger Plate (as per Technical Specification / Sample) in Place of Missing ones at different Tower Locations of 220KV / 132KV Transmission Lines with Proper Tightening including Cost of Danger Plate.
(4) Providing & Fixing of Phase Plate Set (as per Technical Specification / Sample) in Place of Missing ones at different Tower Locations of 220KV / 132KV Transmission Lines with Proper Tightening including Cost of Phase Plate Set.
(B) Normal Maintenance Work on above Transmission Lines (Work during Planned Shut Down) : (1) Tightening of Jumper alongwith Replacement of Fasteners, if Required, to be Provided by the Department as per Requirement on Section Towers of 220KV / 132KV Transmission Lines.
(2) Re-fixing & Tightening of Dislocated / Shifted Conductor Vibration Damper to its Place including Replacement of Fasteners, if Required, to be Provided by the Department as per Requirement on 220KV / 132KV Transmission Lines.
(3) Tightening of Earth Wire Suspension Clamp on 'A' type Towers of 220KV / 132KV Transmission Lines.
(4) Replacement of damaged Earth Wire Copper Bond by New ones to be Provided by the Department on Section Towers of 220KV / 132KV Transmission Lines.
(5) Re-fixing & Tightening of Dislocated / Shifted Earth Wire Vibration Damper to its Place including Replacement of Fasteners, if Required, to be Provided by the Department as per Requirement on 220KV / 132KV Transmission Lines.
(C) Tripping / Breakdown Based Emergency Maintenance Work on above Transmission Lines due to damage of Jumper / Suspension Insulator (Work during Shut Down) : (1) Immediate Diversion / Mobilization of Gang for Attending Break Down due to damage of Jumper / Suspension Disc Insulator / Suspension Disc Insulator String / Suspension Polymer Insulator String with all T&Ps, Man Power etc. Required for Completion of the Work in Bare Minimum Time and Return Back of the Gang after Completion of the Work. (1 Job per Break Down)
(2) Replacement of Damaged Jumper alongwith Replacement of Fasteners with New ones by making Jumper with Compression Joint Method / Replenishment of Jumper with the help of P.G. Clamps on 220KV / 132KV Transmission Lines including Transportation of Materials from Storage Place to Line Site and Back the Unutilised / Received Back Materials to Respective Stores : (a) 220KV Transmission Line
(b) 132KV Transmission Line
(3) Replacement of Damaged / De-Capped Suspension Disc Insulator / Disc Insulator String / Damaged Suspension Polymer Insulator String on Suspension Towers of 220KV / 132KV Transmission Lines including Transportation of Materials from Storage Place to Line Site and Back the Unutilised / Received Back Materials to respective Stores : (a) 220KV Transmission Line
(b) 132KV Transmission Line
(D) Tripping / Breakdown Based Emergency Major Maintenance Work on above Transmission Lines due to damage of Conductor / Earthwire (Work during Shut Down) : (1) Immediate Diversion / Mobilization of Gang for Attending Break Down due to damage of Tension Disc Insulator / Tension Disc Insulator String / Tension Polymer Insulator String / Conductor / Earth Wire of 220KV / 132KV Transmission Lines with all T&Ps, Man Power etc. Required for Completion of the Work in bare Minimum Time and Return Back of the Gang after Completion of the Work. (1 Job per Break Down)
(2) Replacement of Damaged / De-Capped Tension Disc Insulator / Tension Disc Insulator String / Damaged Tension Polymer Insulator String on Section Towers of 220KV / 132KV Transmission Lines including Transportation of Materials from Storage Place to Line Site and Back the Unutilised / Received Back Materials to Respective Stores : (a) 220KV Transmission Line
(b) 132KV Transmission Line
(3) Attending Break Down of Conductor by Replacement / Repairing of damaged Portion of Conductor of 220KV / 132KV Transmission Lines by Way of Releasing the Respective Phase Conductor from Suspension Fitting of the Towers, if Required between the Section Towers, Cutting of damaged Portion of the Conductor, Jointing new Conductor with the help of Mid Span Joint / Dead End Fitting / Repair Sleeve by making Compression Joint. Finally, Re-Stringing and Sagging of the Conductor as per Sag Chart with Clamping the Conductor at Suspension Towers as Required, as per Details below : (a) 220KV Transmission Line : (i) 1 Conductor of 1 Span Section
(ii) 1 Conductor of more than 1 Span Section and Length upto 1 Km
(iii) 1 Conductor of more than 1 Span Section and Length between 1 to 2 Km
(iv) 1 Conductor of more than 1 Span Section and Length more than 2 Km
(b) 132KV Transmission Line : (i) 1 Conductor of 1 Span Section
(ii) 1 Conductor of more than 1 Span Section and Length upto 1 Km
(iii) 1 Conductor of more than 1 Span Section and Length between 1 to 2 Km
(iv) 1 Conductor of more than 1 Span Section and Length more than 2 Km
(4) Attending Break Down of Earth Wire / Replenishment of Missing Earth Wire of 220 / 132 KV Transmission Lines by Way of Releasing the Earth Wire from Suspension Fitting of Towers between the Section, Cutting Damaged Portion of Earth Wire, Jointing of new Earth Wire with the help of Mid Span Joint / Dead End Fitting by Making Compression Joint. Finally, Re-Stringing and Sagging of the Earth Wire as per Sag Chart with Clamping at Suspension Towers as Required, as per Details below (a) 220KV Transmission Line :
(ii) 1 Conductor of more than 1 Span Section and Length upto 1 Km
(iii) 1 Conductor of more than 1 Span Section and Length between 1 to 2 Km
(iv) 1 Conductor of more than 1 Span Section and Length more than 2 Km
(b) 132KV Transmission Line : (i) 1 Conductor of 1 Span Section
(ii) 1 Conductor of more than 1 Span Section and Length upto 1 Km
(iii) 1 Conductor of more than 1 Span Section and Length between 1 to 2 Km
(iv) 1 Conductor of more than 1 Span Section and Length more than 2 Km
LASHANI ENTERPRISES
M/s Abhinav Enterprises
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid