Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NEW MADHOPUR COLONY SURAJKUND GORAKHPUR UTTAR PRADESH 273001 | GORAKHPUR | UTTAR PRADESH | 273001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical 01 KATYANI CONSTRUCTION COMPANY H NO 1 SHOP NO 1 RATAN LAL NAGAR KANPUR NAGAR UTTAR PRADESH 208022 | KANPUR NAGAR | UTTAR PRADESH | 208022 | Not Admitted-Fee/PreQual/Technical Others-Firm not uploaded required paper as mentioned in PQR of bid |
Tender Value
₹43.7 L
EMD Value
₹45,000
Closing Date
23 Apr 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Transmission Circle Agra Kakraitha Road, Near Amar Ujala Press, Sikandara , Agra
Erection of 132 KV Jasrana and Narkhi Bay at 132 KV S/S Shikohabad and Erection of SAS Type 132 KV Bay at 220 KV S/S Sirsaganj under ETD Firozabad
2024_UPTCL_901727_2
ET_42_ETC_A_23_24
Open Tender
Electrical Works
Lump-sum
90 days
Agra
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
EE_A_ETC_AGRA
₹45,000
3 Jun 2024
3 Apr 2024
24 Apr 2024
3 Apr 2024
23 Apr 2024
3 Apr 2024
Supply against for 132 KV Shikohabad bay -II at 220 KV S/S Sirsaganj
Supply of bolted type busbar tension fitting suitable for single Tarantulla conductor made of LM-6 alloy complete with ball eye socket and d shackle single phase type turn buckle in all respect.
Supply of bolted type busbar tension fitting suitable for single zebra/panther conductor made of LM-6 alloy complete with ball eye socket and d shackle single phase type turn buckle in all respect.
Supply of Suspention fitting suitable for single zebra/panther conductor made of LM-6 alloy complete
Supply of Tinned copper bond of size 15x550mm made stranded copper rope with well compressed copper lugs(16mm hole) at both ends.
Supply of post insulator clamp for Zebra / Panther
Supply of four bolted type PG clamp for Zebra to Panther conductor.
Supply of four bolted type PG clamp for Tarantulla to Panther conductor.
Supply of PG clamp for Panther to Panther conductor.
MS Flat 75 x 10mm
MS Flat 50 x 6mm
MS Flat 25 x6mm
40mm M.S. Round for Earthmat
Galv. Nut bolt & Washer
Galv. 16 x 35mm Nut bolt with washer
Galv.16 x 40mm Nut bolt with washer
Galv.16 x 50mm Nut bolt with washer
Galv.16 x 90mm Nut bolt with washer
Galv.12 x 80mm Nut bolt with washer
Galv.10 x 80mm Nut bolt with washer
Galv.10 x 60mm Nut bolt with washer
Erection work of 132 KV Shikohabad Bay II and Dismantling & Re-Erection of 40 MVAR Cap. Bank at 220 KV S/S Sirsaganj
Erection work
Erection of main/ auxiliary structure as per drawing including other associated work to complete this job satishfactorily.
Safe erection of following equipments as per drawing including other associated work to complete this job satishfactorily with the help of required special t&p or crane and skilled labour.
145KV CB (Sas based)
145KV CT/PT JUNCTION BOX
120KV LIGHTING ARRESTORS
145KV BUS ISOLATOR (Excluding post insulator)
145KV LINE ISOLATOR (Excluding post insulator)
145KV TANDEM ISOLATOR (Excluding post insulator)
145KV POST INSULATOR
145KV ISOLATOR BOX
132KV CONTROL & RELAY PANEL (SAS based)
Laying of control cable of size 2c x 2.5mm sq, 4c x 2.5mm sq, 6c x 2.5mm sq & 10c x 2.5mm sq from control room to various equipments as required
Termination of control cable 10 / 6 / 4 / 2 core x 2.5sq mm all equipments and control panel, 132kv bus coupler proper inter / external connection CT, PT, CB, CRP, 132KV Isolators, CT / PT Junction box & isolator box etc.
Stringing work of 132KV bus bar of (1PX36) Panther conductor approx 36 meter long with hoisted of Disc insulators and clamped bolted type Panther Tension fitting including other associated work to complete this job satishfactorily.
Providing interconnection drawing (cable schedule) of 132KV bay from control/ relay panel to junction box to equipment in 3 set of each showing connection all equipments ie CTs, PTs, CBs, Isolators, control & relay panel etc as per drawing (All the drawing provided by department).
Complete earthing of 132KV all equipments, CR panel & 132 KV CB, 132 KV PT,132 KV LA, 1132 KV CT / PT junction box and All Isolators and its box.Their structure by MS flat including, bending, cutting, painting by green color & welding after shifting of MS flat from store or designation place to site.
Delta earthing of 132KV LA consisting of Fabrication of 04no, 3mtrs long electrode (40mm dia MS bar ) its placing 3000mm below ground & connect of All 4 electrode with 75 x 10mm MS flat connection the same with main earthmat at two place MS bus flat & angle will be provided by department.
Complete jumpering work of 132KV Bay by Panther / Zebra conductors including cutting, laying, fixing & clamping etc.
Configuration & SCADA Integration of 132kv line bay
Providing and erection of SAS (RTU) complete set as per 220kv & 132kv s/s TS & Bay integration work
DISMANTLING WORK:-
Dismantling work of main/ auxiliary structure without any damage equipment including other associated work to complete this job satishfactorily.
Safe Dismantling work of following equipments including other associated work to complete this job satisfactorily with the help of required special T&P or crane and skilled labour.
145KV CB (Sas based)
145KV NCT
145KV CAPACITOR UNIT
145KV REACTOR
145KV CT/PT JUNCTION BOX
120KV LIGHTING ARRESTORS
145KV BUS ISOLATOR (Excluding post insulator)
145KV LINE ISOLATOR (Excluding post insulator)
145KV POST INSULATOR
145KV ISOLATOR BOX
132KV C&R PANEL
Openning of all termination of control cable 10/ 6/ 4/ 2core x 2.5mm sq to all equipment and control panel and 132 KV isolators
Destringing work of 132 KV bus bar of (1PX25) Panther conductor approx 25 meter long with hoisted of Disc insulators and clamped bolted type panther tention fitting including other associated work to complete this job satishfactorily.
Safe Dismantling & collection of control cable of size 2c x 2.5mm sq, 4c x 2.5mm sq, 6c x 2.5mm sq & 10c x 2.5mm sq from control room to various equipments and shifted to store or designated place.
Dismantling / cutting of earthing of main / auxiliary structure and all equipment CPR, CT / PT, NCTs , ISOLATOR ,CT / PT Junction box, CBs including other associated work to complete this job satishfactorily.
Opening work of jumpering of 132 KV Bay by Panther/ Zebra conductors including other associating work etc.
Re-ERECTION WORK:-
Re-Erection of main/ auxiliary structure as per drawing including other associated work to complete this job satishfactorily.
Safe Re-erection of following equipments as per drawing including other associated work to complete this job satishfactorily with the help of required special t&p or crane and skilled labour.
145KV CB (Sas based)
145KV NCT
145KV CAPACITOR UNIT
145KV REACTOR
145KV CT/PT JUNCTION BOX
120KV LIGHTING ARRESTORS
145KV BUS ISOLATOR (Excluding post insulator)
145KV LINE ISOLATOR (Excluding post insulator)
145KV POST INSULATOR
145KV ISOLATOR BOX
132KV C&R PANEL SAS BASED
Laying of control cable of size 2c x 2.5mm sq, 4c x 2.5mm sq,6c x 2.5mm sq & 10c x 2.5mm sq from control room to various equipments as required
Stringing work of 132kv bus bar of (1PX36) panther conductor approx 36 meter long with hoisted of Disc insulators and clamped bolted type panther tention fitting including other associated work to complete this job satishfactorily.
Termination of control cable 10/6/4/2corex2.5sq mm all equipments and control panel, 132kv capacitor bank proper inter / external connection CT, PT, CB, CRP, 132KV Isolators, CT / PT Junction box & isolator box etc.
Complete earthing of 132KV all equipments, CR panel & 132 KV CB, 132 KV PT,132 KV LA, 132 KV CT/PT junction box and All Isolators and its box.Their structure by MS flat including, bending, cutting, painting by green color & welding after shifting of MS flat from store or designation place to site.
Delta earthing of 132 KV LA consisting of Fabrication of 04no, 3mtrs long electrode (40mm dia MS bar ) its placing 3000mm below ground & connect of All 4 electrode with 75x10mm MS flat connection the same with main earthmat at two place MS bus flat & angle will be provided by department.
Complete jumpering work of 132 KV Bay by Panther / Zebra conductors including cutting, laying, fixing & clamping etc.
Re-ERECTION WORK:-
Galv. NUT BOLT & WASHER Size 16 x 50
Galv. NUT BOLT & WASHER Size 16 x 45
Galv.NUT BOLT & WASHER Size 16 x 40
Galv.NUT BOLT & WASHER Size 16 x 35
Galv.NUT BOLT & WASHER Size 16 x 90
Galv.NUT BOLT & WASHER Size 12 x 80
Galv.NUT BOLT & WASHER Size 11 x 80
Galv.NUT BOLT & WASHER Size 10 x 80
40MM MS ROUND FOR EARTHMAT
40MM DIA ELECTRODE (3M LONG)
MS FLAT 75 X 10MM
MS FLAT 50 X 6MM
MS FLAT 25 X 6mm
Single Gun tention fitting suitale for ACSR Panther
Single Gun tention fitting suitale for ACSR Zebra / Moose
132 KV lineTension fitting for Panther
Tinned copper bond of size 15 x 550mm stranded rope with copper lugs (16mm hole) at both end
Single suspension fitting for ACSR Zebra / Moose
Single suspension fitting for ACSR Panther
PG-clamp suitable for ZEBRA / ZEBRA
PG-clamp suitable for ZEBRA / Panther
PG-clamp suitable for Panther / Panther
Bus post Clamp suitable for Panther
Bus post Clamp suitable for Twin Panther
Bus post Clamp suitable for Zebra
Erection work of 132 KV Sirsaganj Bay-II and Dismantling & Re-erection of 132 KV Jasrana & Narkhi Bay at 132 KV S/S Shikohabad
PART-A
New Erection work
Erection of main/ auxiliary structure as per drawing including other associated work to complete this job satishfactorily.
Safe erection of following equipments as per drawing including other associated work to complete this job satishfactorily with the help of required special T&P or crane and skilled labour.
145KV CT/PT JUNCTION BOX
120KV LIGHTING ARRESTORS
145KV BUS ISOLATOR (Excluding post insulator)
145KV LINE ISOLATOR (Excluding post insulator)
145KV TANDEM ISOLATOR (Excluding post insulator)
145KV POST INSULATOR
145KV ISOLATOR BOX
132KV DOUBLE FEEDER CONTROL PANEL
132KV DISTANCE PROTECTION PANEL
132KV BUS COUPLER C&R PANEL
Laying of control cable of size 2c x 2.5mm sq, 4c x 2.5mm sq, 6c x 2.5mm sq & 10c x 2.5mm sq from control room to various equipments as required
Termination of control cable 10/ 6/ 4/ 2core x 2.5sq mm all equipments and control panel, 132kv bus coupler proper inter/external connection CT, PT, CB, CRP, 132KV Isolators,CT / PT Junction box & isolator box etc.
Providing interconnection drawing (cable schedule) of 132KV bay & 132KV B/C BAY from control / relay panel to junction box to equipment in 3 set of each showing connection all equipments ie CTs,PTs,CBs,Isolators, control & relay panel etc as per drawing (All the drawing provided by department).
Complete earthing of 132KV all equipments, CR panel & 132 KV CB, 132 KV PT,132 KV LA, 132 KV CT/PT junction box and All Isolators and its box.Their structure by MS flat including, bending, cutting, painting by green color & welding. Flat Provided by deptt. as bellow:-
MS FLAT 75X10MM
MS FLAT 50X6MM
MS FLAT 25X6MM
Delta earthing of 132KV LA consisting of Fabrication of 06no, 3mtrs long electrode (40mm dia MS bar ) its placing 3000mm below ground & connect of All 06 electrode with 75 x10mm MS flat connection the same with main earthmat at two place MS bus flat & angle will be provided by deptt.
Stringing of 1phase(1Px60mtr) 132kv main bus-II zebra/panther bus bar 60mtr approx at hight of 8meter approx in 3 section with proper sagging of bus including fitting of tention clamp , hoisting of insulator, cutting of conductor including all other associated work to complete the job satishfactorily as per technical specification. All labour and T&P provided by the contractor at his own cost.
Stringing of 1phase(1P x 36mtr) 132 KV jack bus zebra/panther bus bar 36mtr approx at hight of 11meter approx in 3 section with proper sagging of bus including fitting of tention clamp , hoisting of insulator, cutting of conductor including all other associated work to complete the job satishfactorily as per technical specification. All labour and T&P provided by the contractor at his own cost.
Complete jumpering work of 132 KV Bay by panther/ zebra conductors including cutting, laying, fixing & clamping etc.
PART-B
(1) DISMANTLING WORK:-
Dismantling work of main/ auxiliary structure without any damage equipment including other associated work to complete this job satishfactorily.
Safe shifting with sorting and stacking of main/ auxiliary steel structure from designated place (Dismantling site) to store site as direction by concerning engineer with help of required special t&p and skilled labour at own cost.
Safe Dismantling work of following equipments including other associated work to complete this job satishfactorily with the help of required special t&p or crane and skilled labour.
145KV CT / PT
145KV CT PT JUNCTION BOX
120KV LIGHTING ARRESTORS
145KV POST INSULATOR
Dismantling / cutting of earthing of main / auxiliary structure and all equipment CPR, CT/PT, NCTs , ISOLATOR ,CT/PT Junction box, CBs including other associated work to complete this job satisfactorily.
Openning of all termination of control cable 10/6/4/2corex2.5mm sq to all equipment and control panel etc.
Safe Dismantling & collection of control cable of size 2cx2.5mm sq,4cx2.5mm sq,6cx2.5mm sq & 10cx2.5mm sq from control room to various equipments And shifted to store or designated place.
Opening work of jumpering of 132kv Bay by panther/ zebra conductors including other associating work etc.
RE- ERECTION WORK
Erection of main/ auxiliary structure as per drawing including other associated work to complete this job satishfactorily.
Safe erection of following equipments as per drawing including other associated work to complete this job satishfactorily with the help of required special t&p or crane and skilled labour.
145KV CT/PT JUNCTION BOX
120KV LIGHTING ARRESTORS
Laying of control cable of size 2c x 2.5mm sq, 4c x 2.5mm sq, 6cx 2.5mm sq & 10c x 2.5mm sq from control room to various equipments as required
Termination of control cable 10/ 6/ 4/ 2core x 2.5sq mm all equipments and control panel, 132kv capacitor bank proper inter/external connection CT,PT,CB,CRP,132KV Isolators,CT/PT Junction box & isolator box etc.
Complete earthing of 132KV all equipments, CR panel & 132KV CB, 132KV PT,132KV LA, 132KV CT/PT junction box and All Isolators and its box.Their structure by MS flat including, bending, cutting, painting by green color & welding after shifting of MS flat provided by deptt..
MS FLAT 75X10MM
MS FLAT 50X6MM
Delta earthing of 132 KV LA consisting of Fabrication of 06no, 3mtrs long electrode (40mm dia MS bar ) its placing 3000mm below ground & connect of All 6 electrode with 75x10mm MS flat connection the same with main earthmat at two place MS bus flat & angle will be provided by deptt.
Complete jumpering work of 132KV Bay by Panther / Zebra conductors including cutting, laying, fixing & clamping etc.
Extention of earthmat including laying of MS round 40/36mm below 500mm ground level.
Fabrication & peairceing of electrode on ground of 3000mm all connected to grid.
SHILPA ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .