MUNICIPAL CORPORATION OF DELHI Office of the Executive Engineer (Elect)-I/East Zone Room No.5 First Floor Vishwakarma Nagar Near Hanuman MandirJhilmil Colony Delhi-110095
Additional requirement for EI and Fans along with provision of AC and other allied works at Jan Rasoi (Closed) as AyAM Shakarpur in Ward No. 202, (Shakarpur),under Shahdara (South) Zone.
2026_MCD_290375_1
EEE-I/2026-27/5.1
Open Tender
Electrical Works
Percentage
15 days
work
Please refer to tender documents
4 documents required · 4 mandatory
₹590
₹5,500
9 Sept 2026
9 Sept 2026
12 Sept 2026
9 Sept 2026
12 Sept 2026
9 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group-C | 2 | Each | 1,704 | ₹3,408 |
| 2 | S&F of suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 6 pin 5/6 & 15/16 amps modular Socket outlet and 15/16 amps modular switch, connection etc. as reqd | 1 | Each | 659 | ₹659 |
| 3 | Wiring for light/ power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 5 | PM | 373 | ₹1,865 |
| 4 | Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU),copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 1.5 TR with 5 Star BEE Rating | 5 | Each | 43,539 | ₹2,17,695 |
| 5 | S/I/T/ C of 4 KVA Voltage stabilizer having input voltage 150V - 270V and output voltage of 195 V -245 V . | 5 | Each | 3,361 | ₹16,805 |
| 6 | S/I/T/C of stand for split AC | 5 | Each | 788 | ₹3,940 |
| 7 | S/I/T/C of copper pipe for split AC | 12 | Metre | 838 | ₹10,056 |
| 8 | S/I/T/C of Drain Pipe | 30 | Metre | 106 | ₹3,180 |
| 9 | S/I/T/C of 3 Core, 4 Sqmm. Electrical wire for Air Conditioner | 18 | Metre | 158 | ₹2,844 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
condition.pdf
Tender Documents • 0.39 MB
BOQ_338661.xls
BOQ • 0.27 MB
viewsbd.pdf
Additional Documents • 15.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .