Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAccepted-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹34.4 L+₹3.2 L (10.2%)Rejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | L2 | Rejected-Finance NOT REASONABLE | |
| 3 | L3₹35.4 L+₹4.1 L (13.3%)Rejected-Finance NOT AVAILABLE | L3 | Rejected-Finance NOT REASONABLE | |
| 4 | L4₹36.2 L+₹5.0 L (16.1%)Rejected-Finance | L4 | Rejected-Finance NOT REASONABLE | |
| 5 | L5₹37.4 L+₹6.1 L (19.6%)Rejected-Finance 86 CHAK16 QAZIPURA TANDA RAMPUR UTTAR PRADESH 244925 | RAMPUR | UTTAR PRADESH | 244925 | L5 | Rejected-Finance NOT REASONABLE |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
13 Sept 2024, 6:00 pmClosed
Saurabh Gupta, EE
GE (West) Colaba, Mumbai
SPECIAL REPAIR OF NCC PL LINE 1ST ARMD AND DTE STORE BLDG AND BLDG NO P-1/2 JACOB HOUSE UNDER GE (W) COLABA, MUMBAI
2024_MES_667351_1
8912/E8
Open Tender
Civil Works
Item Wise
180 days
GE (West) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (West) Colaba, Mumbai
₹96,000
Yes
3 Dec 2024
22 Jul 2024
16 Sept 2024
22 Jul 2024
13 Sept 2024
4 Aug 2024
Amount
Dismantling of floor hearth/wall tiles including cement mortar bedding (but not backing) and removing serviceable tiles all as specified and directed.
M&L for Non skid coloured ceramic tiles 7 to 8 mm thick, area of each tiles exc 0.11 sqm but not exc 0.18 sqm as in floors including 15mm thick screed bed or bedding layer in CM (1:6) set and jointed in neat cement slurry and pointed in coloured cement to match the shades of the tiles all as specified and directed.
M&L first and premium quality Anti skid, HD ceramic digital “coloured” glossy/matt finish joint less tiles of size 300 x 300 x 6-7mm or thick, in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed of bedding layer in CM 1:6 all as specifed and directed.
M&L first and premium quality HD Glazed ceramic coloured digital tiles in vertical surface 600X 300X 7 / 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including 10mm thick rendering coat in CM 1:4 with 6 mm spacer filled with epoxy grout all as specified and directed.
M&L vitrified ceramic tiles 7-8 mm thick, area of each tiles exc 0.18 sqm but not exc 0.38 sqm as in floors including 15mm thick screed bed or bedding layer in CM (1:6) set and jointed in neat cement slurry and pointed in coloured cement to match.the shade of tiles with 6 mm spacer filled with epoxy grout all as specified and directed by engr in charge.
M&L Vitrified tiles dark or light shade /double charge /ultra charged 600 x 600 x 10-12 mm thick (square/ rectangular) polished, size of each tiles in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shed of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 all as specified and directed.
M&L Vitrified tiles dark or light shade /double charge /ultra charged 10-12 mm thick cut to size (square/ rectangular) polished, on vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shed of tiles, laid over and including 10mm thick rendering or backing layer in cement mortar 1:4 all as specified and directed.
M&L ceramic tiles 8-10 mm thick, area of each tiles exc 0.42 sqm but not exceeding 1 sqm as in Vertical surface/skirting including 10mm thick rendering/backing coat in CM(1:4) set and jointed in neat cement slurry and pointed in coloured cement to match the shades of the tiles all as specified and directed.
M&L 8 mm thick laminated wooden flooring, water resistant, termite resistant, polished flooring is a flating glue less click locked & sealed flooring similar ta a jigsaw puzzle. In this method, the individual planks are locked on the each other by means of the clicking together but do not attach to the sub floor on which it is being installed all as specified and directed.
M&L Granite (of any type and size) 18-20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over 15mm thick screed bed in CM 1:6 on kitchen platform, Cill of Window/Ventilator/ flooring/border etc including rubbing, grinding and polishing all as specified and directed
M&L 20-25 mm thick machine cut cudappa stone slab in horizental/vertical jambs laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing & rounding to edges of slab as in window cills/jambs including screed bedding 10mm thick in CM 1:6 all as specified and directed by Engineer-in-charge..
M&L Molding (Sandwitch moulding) of granite slab edges as directed by Engr-in-charge including polishing complete
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided all as specified and directed.
M&L Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified and directed.
M&L 75 mm thick PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate ) as in sub base & similar work including necessary expansion joints filling with bitumen at a certain distance all as specified and directed.
M&L PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) finished surfaces even and rough to receive the tiles all as specified and directed.
M&L PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in bed blocks for hold fast all as specified & directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including snap grid frame work all as specified and directed.
M&L for E-board tiles ceiling on GI powder coated channel/Tee/Grid of make (Armstrong or equivalent) frame work with the following specification including cutting holes in brick wall built in cement mortar & making good in cement concrete 1:2:4 type BO/Cement mortar 1:3 all as specified and directed with following specification:- (a) M&L Plugging to wall around the rooms & supplying & fixing GI powder coated angle of make (Armstrong or equivalent) of size 25 x 25 mm (b) S&F 1.60 mm dia GI wire suspenders with adjustable clamps including fixing to ceiling with dash free fasteners (c) S&F GI powder coated tee as in main & cross members at 595 mm centre to centre supported suspenders along with adjustable clamp to maintain level. (d) S&F E-board ceiling tiles of size 595 mm x 595 mm x 4 mm thickness, confirming to relevant IS in squares of GI powder coated tee with clips made to shape, shade and pattern of tiles shall be as approved by GE
S&F in repairs 18 mm thick both side pre laminated HDHMR Board of any colour, matt surface finish, grade I as per IS 14587, for frame and shutter for kitchen cabinets/ vanity complete with all necessary fittings like stainless steel hinges, brass, handles and magnets all as specified and directed.
M&L Solid PVC Wall Lining consisting of 5mm thick Wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing all as specified and directed.
M&L 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing.
Dismantling single layer manglore pattern or similar tiles in roof covering ridges hips and valley gutter all as specified icluding ridge with scaffolding where required all as specified and directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings including ridges all as specified and directed.
Dismantling of battens for tiles, shingles etc, of any size including tilting fillets exc 15 cm c/c spacing all as specified and directed..
Dismantling timber in scantlings 40 Sqcm and over in section, in unframed work in any position all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
S&F for Rolled mild steel sections conforming to Gde Fe-290 (Gde-165-E) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails & guides for sliding doors, fixed with angle cleats or other connecting plates all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
M&L except Sheeting Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
M&L for preparation of new untreated steel surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F Second class hard wood clean sawn boarding 25mm thick with butt joints in any situation except flooring & skirting all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles including removing debris out side MD land all as specified and directed.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 all as specified and directed.
M&L Brick work with sub class 'B' brick straight or curved on plan in any radius in half brick thick walls built in CM 1:4 all as specified and directed.
Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site out side MD land all as specified and directed.
Demolition of re-inforced cement concrete (re-inforce cut as required to facilotate demolition) in any position ( Beam, landing Chajja and Roof slab etc ) ground floor/ other than ground floor, projection of balcony all as specified and directed.
M&L RCC M-25 Design Mix (using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span supported on walls all as specified and directed
Use & waste special water tight centering and shuttering including bolting, strutting, propping etc. so as to with stand a pressure of 0.1 Mpa including removal of form work all locations including beams, columns, slabs, walls, foundations, footings, landings, stairs, balconies all as specified and as directed.
M&L MS TMT bars 10 mm dia and over out to length, bent to shape required, including cranking, bending including necessary welding as required & binding with mild steel wire (annealed) not less than 0.90mm dia or securing with the lips all as specified and directed.
M&L 12 mm thick Ready Mix Plaster in single layer, on other than fair faces of concrete surfaces in wall and finished surfaces even and smooth without using extra cement all as specified and directed.
M&L for complete removal of old plastered surface of wall and applying two coats of oil emulsion distemper over a coat of alkali resistant primer coat with a coat of wall care putty through authorised applicators of paint manufacturers only of approved shade all as specified and directed
M&L for preparation of newly plastered surface of wall and applying two coats of oil emulsion distemper over a coat alkali resistant primer coat with a coat of wall putty through authorised applicators of paint manufacturers only of approved shade all as specified and directed
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided all as specified and directed.
M&L sub base 75 mm thick PCC 1:4:8, type D2 (using 40 mm graded crushed stone aggregate) all as specified and directed.
M&L machine pressed precast concrete interlocking paver block glossy finish of any shape and size confirming to IS 15658 - 2006 of 60 mm thickness, M- 35 grade with grey cement and pigment including 40 mm thick sand cushioning layer all as directed and specified
Taking down chowkat with shutters (without taking off shutters from the frames ) area nexc 1.5 sqm each all as specified and directed.
Taking down shutters of any description area exc 1.5 sqm each all as specified and directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 150 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made all as specified and directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 28 to 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: stainless steel butt hinges and necessary S S screws shall be paid separately all as specified and directed
S&F 2nd class hardwood factory made door, 28 to 30 mm thick, glazed and skeleton shutters, open rebated and prepated to receive glass gauze etc (with sash bars) edges of framing plain, chamfered or rounded materials and revated sash bars any number , edges of framing plain chemfered or rounded fitted with cut and mitred beads for securing glass in door etc or provided with styles and rails as specified in SSR part 1 section 8, clause 8.20 (a) all as specified & directed.
M&L for preparing wooden new surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
S&F 150 mm long aluminium alloy handle cast type anodized all as specified and directed.
S&F 150 mm long aluminium anodized barrel tower bolt of extruded section all as specified and directed
S&F 300mm long MS sliding door bolts, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including minimum of 6 bolts and nuts, four on bolt plate and two on staple all as specified and directed.
S&F 100mm long Aluminium butt hinges of extruded aluminium alloy with galvanized mild steel hinge, pin anodized all as specified and directed.
S&F powder coated aluminium sections for doors, windows, ventilators, door partition including fabrication of frame shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement including all accessories such as glazings clips, and rubber beadings for fixing glass panes in frame complete all as specified and directed. Note : (i) Glass panes will be measured & paid separately . (ii) The quoted rate shall be inclusive of cost of rubber beading however it will be not be weighed and not paid separately. (iii) All other minor details including cost of locking arrangement shall be included in the quoted rate. (iv) Windows all around will be sealed with silicon sealant.
M&L 4.8 mm thick sheet glass, pin head type and glazing with oil putty in square nexc 0.5 sqm in each pane all as specified & directed.
S&F aluminium grill of 6 mm thick of opening as per design pattern DG 103 fixed with aluminium channel 'F ' 20mmx15mm fixed in position with screw all as specified and directed.
M&L galvanised M S Wire cloth of 0.56 mm nominal dia of wire and average width of aparture 1.18 mm fixed with tinned tack for galvanized wire staple all as specified & directed.
M&L 15 mm thick rendering in cement mortar 1:4 mixed with liquid waterproofing admixture as per manufactures instructions of brick work/ concrete surface and finishing surfaces fair and even and smooth without using extra cement all as specified and direcetd. Note: (i) WPC shall be measured and paid for separately as 'Supply only'. (ii) WPC to be mixed @200ml per 50 Kg bag of cement all as manufacturers instruction.
Supply only integral water proofing compound all as specified and directed.
M&L 12 mm thick Ready Mix Plaster in single layer on other than fair faces of concrete surfaces in wall ( internal surface ) and finished surfaces even and smooth without using extra cement all as specified and directed.
M&L plastering 12 mm thick average Polymer modified mortar (ready mix pack) in finishnig coat after guniting, finishing the surfaces even and smooth without using extra cement, curing and removing the debris outside MD lands as per manufacturer's instruction including two coat of white wash all as specified and directed. Note;- Please note that rate of polymer included in the quated rate.
M&L for complete removal of old plastered surfaces and applying two coats of weather proof acrylic exterior paint (100% Acrylic) Base coat of Apex ultima protek duralife or equivalent and top coat of Apex Ultima protek or equivalent, over a coat of alkali resistent primer through authorized applicator only including use of scaffoldings all as specified and directed.
M&L for preparing newly plastered surfaces and applying two coats of weather proof acrylic exterior paint (100% Acrylic) Base coat of Apex ultima protek duralife or equivalent and top coat of Apex Ultima protek or equivalent, over a coat of alkali resistent primer through authorized applicator only including use of scaffoldings all as specified and directed.
Demolition/ taking down existing roof treatment including PCC padding by picking sweeping, cleaning and washing down with water to remove dust, durt and brushing neat cement slurry @ 3 KG/sqm all as specified and directed.
M&L PCC padding 1:2:4, type B0 (using 12.5mm graded crushed stone aggregate) of thickness 25mm average top surface of plain cement concrete padding shall be furnished even and smooth without using extra cement all as specified and directed.
M&L 15 mm thick screed bed in CM 1:4 all as specifed and directed.
M&L for applying Bituminious primer on roof surface conforming to IS-3384 bof 1986 @ 0.70 Kg/sqm and ap[plying APP based polymeric membrane minimum weighing 3 Kg/sqm and minimum 3 mm thick reinforced with non-woven polyster matt laid on primed surface by torch application all as specified with overlap of 100 mm overlap to be thermo fushion by flame all as specified and directed.
M&L for one coat of aluminium paint at the rate of 100 gms/sqm as per manufacturers instructions over bituminious layer all as specified and directed.
M&L for Anti-termite treatment of voids in masonry using chemical emulsion one litre per hole, at 300 mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors all as specified and directed.
Tanking down old board shutter Modular shutter including all fittings all as specified and directed.
S&F 18 mm thick marine ply board laminated of any colour with high glossy acrylic sheet of 3 mm thick grade I as per IS 14587 for frame and shutter for kitchen cabinet all as specified and directed.
S&F medium weight, cold rolled mild steel, SS finish (Partial overlay/fully overlay of any type) diameter of cup 35mm, Hinge cup depth 11.5mm, self-closing all as specified and directed.
S&F stainless steel 304 electro-polished for corrosion resistance modular thali holder/basket having size of 42 x 58.5 x 20 cm including telescopic drawer channel having weighing capacity of 6 kg all as specified and directed.
S&F stainless steel 304 electro-polished for corrosion resistance modular cup & saucer holder/basket of size 52 x 53.5 x 10 cm with telescopic drawer channel having weighing capacity of 4kg all as specified and directed.
S&F round stainless steel 304 grade 200 mm length cabinet/drawers handles all as specified and directed.
S&F stainlesss steel modular perforated cutlery basket SS 304 of size 52x48.5x10 cm with telescopic drawer channel having weighing capacity of 6 kg all as specified and directed.
S&F grain trolley SS 304 with telescopic drawer channel having weighing capacity of 6 kg all as specified and directed.
S&F stainless steel 304 grade size 180x515x585 mm pull out detergent/spice rack having three shelf with telescopic drawer channel having weight capacity 6 kg all as specified and directed.
S&F butt hinges cast brass with, bright polished and fixed type B-11 of size 100mm all as specified & directed.
S&F 150 mm extruded brass handles, fabricated type polished all as specified & directed.
S&F brass barrel tower bolts of extruded section 200 mm long all as specified & directed.
S&F 300mm long brass sliding door bolts with sand or die-cast brass hasp staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed all as specified and directed.
S&F for Stainless steel plate rack (utensil rack) of size ( 1100 mm x 900 mm) and depth 300 mm made with 0.63 mm thick stainless steel sheet provided with brass screw including necessary fittings, nut/bolts fixed all as specified and directed.
S&F magnetic catches with steel body ‘H’ type, fixed to shutter all as specified and directed.
Taking down carefully copper/aluminum point wiring light/fan/sockets outlet/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling all as specified and directed.
M&L for Point wiring (concealed type) with 1.5 sq mm, PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including rigid non-metallic PVC heavy duty conduit (ISI mark), 19/ 20 mm dia suitable size including cutting chases for conduits, sinking for concealed boxes and for concealed conduit wiring with all fittings and accessories including modular cover plates as required with and fix conecaled 1.2 mm thick pressed steel modular sunken box, suitable for fixing moduler switch socket and unsheathed (FRLSH) single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly and making good to the disturbed surfaces to match with the existing surfaces complete (fill up cement in gaps, finishing with putti and apply two coats of paint, match with existing colour in disturbed surface area), as per IS specification and as specified in SSR Part-I complete for one light point controlled by one modular switch, 1 way 6/10 amps, 1 module.
All as per Srl item No. 91 above but for ceiling Fan controled by one switch .
All as per Srl item No. 91 above but for Exhaust Fan controled by one switch .
All as per Srl item No. 91 above but for socket outlet point 5 Amp on same board.
All as per Srl item No. 91 above but for socket outlet point 5 Amp on Independent board.
All as per Srl item No. 91 above but with 2.5 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point)
All as per Srl item No. 91 above but with 4 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) all as specified and directed. Note Earthing wire should also be of 4 sqmm.
S&F modular switch 1 way 6 A module 230/250 volt, AC supply, ISI marked, with white cover plate with frame all as specified and directed.
S&F modular switch 1 way 16 A module 230/250 volt, AC supply, ISI Marked, with white cover plate with frame all as specified and directed.
S&F modular sockets 6A 2/3 pin combined 2 module 230/250 Volts, 50 Hz , AC supply, ISI Marked, with cover plate all as specified and directed.
S&F modular sockets 6A/16A 2/3 pin combined 2 module 230/250 Volts, 50 Hz , AC supply, ISI Marked, with white cover plate with frame all as specified and directed.
S&F modular Fan step/ electronic regulator, 120W - 2 module A module 230/250 volt, AC supply, ISI Marked, with cover plate all as specified and directed.
S&F ceiling rose surface bakelite 65x50mm, 3 terminal all as specified and directed.
S&F LED Batten lights fitting 1x 20W, 220V, AC decorative box type, warm white / white type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose pre wired fixed to wall with 2 nos PVC block of suitable size all spcifided and directed. Note: Connection should be made neatly using two core flexible cable.
S&F in repairs surface mounted 9/10 watts LED tube light fittings and electrically conncected with suitable size of pvc insulated multistranded copper flexible cable from ceiling rose to light fitting all as specified and directed.
S&F recess mounted low glare luminaire 40 watt 2 X 2 complete with all accessories all as specified and directed.
S&F Exhaust fan 230 volt, 250 mm heavy duty Plastic body with louvre and wooden frame including making all electric connection all as specified and directed including cutting of hole on wall and makng good to disturbed surface of wall and outer wooden box for fan fix on wall including taking down old exhaust fan and deposit to old MES store safely without any damage. Connection should be made neatly using two core white flexible cable all as specified and directed.
M&L refixing of ceiling fan (old fan) and connecting up including provision of cable from ceiling rose or connector and fan rewinding & spray painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust with taking down fan, sealing cable end, dismantling romoving and hanging fan with rod of required length and proper hook and blades and removing fan and blades to store all as specified and directed. Note: Connection should be made neatly using two core flexible cable.
S&F in repairs down rod 8 feet long, made out of 15mm GI pipe, heavy duty, ISI marked having provision of fixing U clamp with and including drilling in pipe at top and bottom for fixing fan motor assembly, painting with superior quality white colour synthetic enamel paint all as specified and directed.
S&F in repairs down rod 10 feet long, made out of 15mm GI pipe, heavy duty, ISI marked having provision of fixing U clamp with and including drilling in pipe at top and bottom for fixing fan motor assembly, painting with superior quality white colour synthetic enamel paint all as specified and directed.
Taking down, repair, thorughly cleaning, spray paint and refixing exhaust fan 230 volt, 300 mm metal body with louvre and wooden frame including replacement of damaged parts , such as blades, motor, bearings, metal louvre, spray painting with gray colour etc in order to make exhaust fan smooth in operation by making all electric connection all as specified and as directed including cutting of hole on wall and making good to disturbed surface of wall and outer wooden box for fan fix on wall all as specified and directed. Note : Connection should be made using two core white flexible cable.
Taking down, repair, thorughly cleaning and refixing Plastic Exhaust fan 230 volt, 250 mm metal/plastic body with louvre and wooden frame including replacement of damaged parts , such as blades, motor, louvre, plastic body in order to make exhaust fan smooth in operation by making all electric connection all as specified and as directed including cutting of hole on wall and making good to disturbed surface of wall and outer wooden box for fan fix on wall all as specified and directed. Note : Connection should be made using two core white flexible cable.
M&L for taking down and refixing of Electric water Heater (Geyser) and connecting up including replacement of old defective parts with new parts inner and outer covering made of copper, thermistor, heating element, indicator lamps, valves, connector pipes, fixing hooks for geyser of 25/ 50 Lit all as specified and directed by Engr-Incharge. Note: Connection should be made neatly using two core white flexible cable.
S&F in repairs LED security Building light LED 35/45 Watt, pressure die cast aluminum housing, heat resistant glass, IP65/66 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light all as specified and directed. Note : Rate quoted should be inclusive of three core cable for connection.
S&F in repairs MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down all as specified and directed.
S&F in repairs MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity 'C' series all as specified and directed including taking down old one all as specified and directed.
S&F in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB's all as specified and directed.
Taking down carefully copper/aluminum submain/ Cable wiring complete including all fixtures and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces all as specified and directed.
M&L for Sub main wiring with four run FRLSH of 10 sq mm stranded copper conductor PVC unseathed FRLSH wire along with 10 sq mm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduite of adequate size (not less than 32 mm dia) for housing the wires for from Panel / Main DB to house TPN/SPN DB including taking down old Unsv submain with all associated fixtures all as specified & as directed by engr-in-charge. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Mode of measurement four runs of 10 sqmm cable and one run of 10 sqmm cable with PVC conduite shall be measured as one length.
Supplying, laying, commissioning & testing LT underground cables 16 Sqmm X 2 Core, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded aluminium conductor all as per IS 7098 (Part -1) laid in trenches, ducts, drawn through pipes or fixed on poles, as and when required all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth strip of size 25 x 4 mm by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/C both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.
Unitech Enterprises (BID ID -3089776)
SHREE JAGDISH FURNITURE CO. (BID ID -3084831)
N.S.ENTERPRISES (BID ID -3094808)
N F ENTERPRISES (BID ID -3086744)
Anil Industrial Corporation (BID ID -3090494)
Bidder Name
Unitech Enterprises
HINDUSTAN BUILDERS
Anil Industrial Corporation
SHREE JAGDISH FURNITURE CO.
N.S.ENTERPRISES
N F ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .