Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹63.4 LAccepted-AOC 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹64.4 L+₹40,363.50 (0.63%)Rejected-Finance H NO 327 KRISHNA ENCLAVE HIMMATGARH PO DHAKOLI ZIRAKPUR 140603 | S A S NAGAR | PUNJAB | 140603 | L2 | Rejected-Finance High Rate Quoted | |
| 3 | L3₹74.8 L+₹10.8 L (16.9%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L3 | Rejected-Finance High Rate Quoted |
Tender Value
₹80.3 L
EMD Value
₹1.5 L
Closing Date
22 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Shery Goel, CWE Bikaner
HQ CWE Bikaner, Bikaner Mil Stn
Spl repair to Bldg No P-03 (Vintage Bldg), Single OR living of C Arty Regt at Bikaner Mil Stn
2024_MES_650117_1
CA No CWE BKN-Token No. 117/2023-2024
Open Tender
Civil Works
Item Rate
270 days
GE N BIKANER
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (N) Bikaner
₹1.5 L
Yes
8 Jul 2024
15 Apr 2024
29 May 2024
15 Apr 2024
22 May 2024
8 May 2024
15 Apr 2024 - 25 Apr 2024
Amount
Demolition of unreinforced cement concrete of any description and in any position (not otherwise specifically provided for in this Schedule, complete all as specified & as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Taking down cement plaster or cement lime plaster, terrazo etc on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed.
M&L for Raking out joints/ pointing to stone slab or precast concrete slab floor any description, laid flat, work built in cement or cement lime mortor complete all as specified and directed.
Dismantling of cast iron, wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.
Taking down shutters (including fittings & fixtures) of any description exc 1 Sqm and not exc. 2 Sqm each and refixing in the same opening after necessary easing adjustment etc, complete all as specified and as directed.
Taking down shutters (including fittings & fixtures) of any description exc 1 Sqm and not exc. 2 Sqm each, complete all as specified and as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
M&L for anti-termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified & as directed.
M&L for anti-termite treatment to at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified & as directed.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
Supply only integral water proofing compound (ISI marked) complete all as specified & as directed.
M&L for Chhatri of Rajasthani heritage pattern of overall size 0.60m x 0.60m x 0.90m of cement concrete with and including stone concrete set & fixed in CM 1:3, complete all as specified and directed.
M&L for Rajasthani heritage pattern water drain 900mm long of dholpur stone as approved by GE, set & fixed in CM 1:3, complete all as specified and directed.
M&L for repair to existing chhattri of any size and pattern and at any height and give them original shape and size complete all as specified & as directed.
M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with old size Fly Ash bricks, straight or curved on plan not exc 6.00 metre with fair cut and rubber bricks or purpose moulded bricks as in ornametal design of haritage pattern built in cement mortar 1:4 complete all as specified and as directed.
M&L for brick work with old size Fly Ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
M&L for 5cm thick sand stone slab in sunshades, chajjas, shelves, cills, landings, cover stones, templates etc not exc 2m in length, punched dressed on face and along exposed edges, self faced on the other side and set and pointed in cement mortar 1:4, including dismantling of stone slabs and tiles complete all as specified & as directed.
M&L for Jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted and set, jointed and grouted in cement mortar 1:3 including dismantling of stone slabs and tiles complete all as specified & as directed.
S&F Segmetal worked from solid chowkats and frames, of first class hardwook, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified & as directed.
S&F plain, solid, straight chowkats and frames, semi circular of first class hardwood, worked from the solid in two or more sectiors dowelled and keyed with double headed hardwood keys, wrought, framed rebated on the solid rounded or chamfered, put together with glue, pinned at joints, complete all as specified & as directed.
Supply and fixing factory made 30mm thick plain framed, paneled shutter (Two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood rail and styles, fixed to chowkat, complete all as specified & as directed.
Supply and fixing factory made 35mm thick glazed and skeleton shutters made of second class hard wood, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in clause 8.24(a) of Section 8 in SSR Part-I, kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified & as directed.
M&L for 19mm thick Veneered Block boards, grade 2 quality, interior grade, commercial type, for cup board fixed with screws to timber framework with decorative film mica face veneered on both faces with proper cover fillet or beading with standard hard board 4.5mm thick bording plain on side with butt joints with including complete all as specified and as directed.
S&F 75mm long butt hinges, cast brass with mild steel hinge pin (ISI marked), bright polished and fixed type C-22 complete all as specified and as directed.
S&F 100mm long butt hinges, cast brass with mild steel hinge pin (ISI marked), bright polished and fixed type B-11 complete all as specified and as directed.
S&F 100mm long mild steel barrel tower bolts, stove enameled black with bright bolts and fixed complete all as specified and as directed.
S&F 150mm long mild steel barrel tower bolts, stove enameled black with bright bolts and fixed complete all as specified and as directed.
S&F 200mm long barrel tower bolts, brass cast type polished bright with bright bolts and fixed complete all as specified and as directed.
S&F 150mm long barrel tower bolts, brass cast type polished bright with bright bolts and fixed complete all as specified and as directed.
S&F 100mm long, brass handle cast type polished bright with bright bolts and fixed complete all as specified and as directed.
S&F mild steel pressed handle, 100mm size, oval type, stove enameled black complete all as specified and as directed.
S&F mild steel pressed handle, 150mm size, oval type, stove enameled black complete all as specified and as directed.
Supply & fixing hasp and staple of size 75mm aluminium anodized safety type with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified.
S&F 250mm long mild steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified & as directed.
S&F 250mm long brass cast type polished sliding door bolt with hasp, staple (Bolt type) and fixing clips of sheet, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified & as directed.
Supply and fixing Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Supply and fixing Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, fixed in repairs, complete all as specified and as directed.
S&F in repairs stainless steel drapery rod of 25mm inner dia & 1.6mm wall thickness (in lengths as directed) with & including stainless steel sockets & decorative finial at both ends and pair of stainless steel brackets & stops fixed at both ends with PVC rawl plug & steel screws on walls/beam complete all as specified & as directed.
S&F rolled mild steel as in Joist, channel, angle or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length directed) and similar work conforming to Grade E-250 quality `A’ all as specified and as directed.
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work including welding conforming to Grade E-165 (Fe 290), complete all as specified & as directed.
S&F aluminium work powder coated of any colour as approved (thickness of powder coating not less than 50 micron) as in frame & shutters for doors, windows, ventilators, wall partitions, including joining cleats, glazing clips, snap beading, screws for fixing, etc., all aluminium sections as per relevant IS, complete all as specified & as directed. Note : Glass and rubber neoprene packing / rubber gasket shall be measured and paid for separately as “Supply only” under respective item of this Schedule.
Supply only rubber neoprene packing / rubber gasket of required size & profile suitable for aluminium frame work in doors, windows, etc complete all as specified & as directed.
S&F aluminium powder coated of any colour as approved (thickness of powder coating not less than 50 micron) grill of approved pattern for windows / ventilators / doors complete as directed and all as specified.
Supply only sheet glass 5.5 mm thick ordinary quality and glazing with oil putty in required sizes, each pane, complete all as specified and as directed (for aluminium door/ partitions).
M&L for cleaning of all loose dirt and dust from roof and priming the surface with one coat of cold applied bituminous primer @ 0.40 litre/sqm and provide a layer of APP based polymeric membrane minimum weighing 3 Kg/sqm and minimum 3mm thick, reinforced with polyester non woven fabric (weighing not less than 150 gms/sqm) laid on primed surface complete all as described in Para 11.44.5 of SSR Part-I, complete all as specified and as directed. Note : The net area of water proofing treatment shall be measured without any extra allowance for laps.
M&L for Lime concrete terracing in roof with minimum thickness at edge 40mm and increasing uniformly towards ridges to obtain a chain slope of (1:40) as described in Para 11.27.2 of MES Schedule Part-I including demolition of lime concrete of any description and in any position complete all as specified & as directed. Note : For lime concrete mudia kankar (Source : NAL) and Kolayat coarse sand in lieu of brick aggregate and surkhi respectively as specified in MES schedule Part-I shall be used.
Roughening surfaces of old concrete surface by picking up, sweeping, cleaning and washing down with water to remove dust, etc. including taking down tarfelt and brushing neat cement slurry @ 3 Kg/sqm mixed with water proofing compound including 20mm thick screeding in cement and sand mortar 1:4 finished even and smooth mixed with water proofing compound complete all as specified & as directed.
M&L for 50mm thick PCC (1:3:6) type C1 using 20mm graded crushed stone aggregate as in flooring, leveling course, etc, over stone patti/RCC roof slab, surface finished fair and even, complete all as specified and as directed.
M&L for 25mm thick PCC (1:2:4) type B0 using 12.5mm graded crushed stone aggregate as in flooring, leveling course, etc, surface finished fair and even, complete all as specified and as directed.
M&L for machine cut Kota stone slab flooring 20 to 25mm thick laid over & including screed bed or bedding layer of 20mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.
M&L for machine cut Kota stone slab 16 to 18mm thick on vertical surfaces such as dado, skirting etc. laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.
M&L for 18 to 20mm thick Granite (of any type) machine cut slab of approved shade (table rubbed and polished) with true & uniform joints as in steps, jambs, pillars, window cills, cooking platforms & like and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed (bedding layer) in CM 1:4 with cement slurry @ 3 Kg/Sqm complete all as specified & as directed. Note : The exposed edges of granite stone slab shall be made full round & polished to mirror finish and rate quoted shall deemed to include this provision.
M&L for 16 to 18mm thick, 100mm wide strip of Makrana white Marble work mechine cut bedded jointed and pointed & including 15mm thick screed bed (bedding layer) in CM 1:4 complete all as specified & as directed.
Rounding (making full moulding) to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified & as directed.
M&L for cutting and grinding of the existing Terrazzo/Marble/Kota stone flooring, skirting, dado, etc by mechanical process using Carborundum stone of appropriate grit, cleaning, making good joints with white cement slurry mixed with pigment to match the shade of the slab and finally mirror polishing by applying wax polish complete all as specified in SSR and as directed.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for factory made Terrazzo tiles, 20cm x 20cm x 20mm thick, with size of chips upto 12 mm, with grey cement & no pigment, set, jointed and pointed in neat cement slurry over roof, and cut and polished, over & including 15mm thick screed bed in cement & sand mortar 1:6, including dismantling old tiles complete all as specified & as directed.
M&L for glazed ceramic tiles (coloured) 7mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e 450mm x 300mm or as directed), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished even and smooth without using extra cement complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:30 in alternative bays not exceeding 4 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
M&L for rendering 20mm thick in cement mortar 1:4 on other than fair faces of brick masonry or concrete surfaces of walls of haritage construction, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement, complete all as specified and directed. Note : Supply only integral liquid water proofing compound shall be measured and paid for separately.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement, complete all as specified and directed. Note : Supply only integral liquid water proofing compound shall be measured and paid for separately.
M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.
M&L for flush pointing in cement mortar 1:3 to self faced / rough dressed stone slab or precast concrete slab floors, any description, laid flat, complete all as specified & as directed.
M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for preparation of old surfaces (plastered or unplastered) of ceilings including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying two coats of white wash complete all as specified & as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer complete all as specified & as directed.
M&L for preparation of old plastered or unplastered surfaces of walls and applying one coat of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer complete all as specified & as directed.
M&L for applying 3mm thick layer wall care putty on walls to give uniform finish on newly plastered surface complete all as specified & as directed.
M&L for preparation of plastered/unplastered surfaces of walls and applying two coats of weather proof acrylic emulsion paint (exterior grade) of approved shade/tint over a coat of primer complete all as specified & as directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered/ unplastered surfaces of walls and applying two coats of weather proof acrylic emulsion paint (exterior grade) of approved shade/tint over a coat of primer complete all as specified & as directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, including hacking out old broken glass any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.
M&L for cutting chases, pinning in, making good to facings as original where required and pointing in cement mortar 1:3 for concealed water tubing and making good, cutting not exc 10 cm girth in brick walls, complete all as specified & as directed.
S&F stack clamp made out of MS flat 50mm x 5mm and 16 mm dia round iron stays, including bolts & nuts, securing ends of stays to walls or roof for 100mm bore pipe including two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified & as directed.
S&F in replacement of 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls complete all as specified & as directed.
S&F 110mm bore PVC (SWR) bend any redius, joint with solvent cement complete all as specified & as directed.
S&F 110mm bore PVC (SWR) Junction, double (single ‘T’) equal or unequal with access door complete all as specified & as directed.
Taking down carefully existing unserviceable/ perished surface conduit/ concealed conduit/ batten/ casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/ conduit/ casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators, wooden boxes, MS sunken boxes, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for Modular point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular switches, sockets, regulators etc with and including modular cover plates with frame of requisite module, complete all as specified and as directed. Notes : (i) Cost of cutting/leaving forming chases for conduits, sinking for modular metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed to include for modular metal flush boxes of requisite module and modular cover plates with frame of requisite module of colour as approved by GE.
All as per serial item No. 86.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified and directed.
All as per serial item No. 86.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 86.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.
S&F Modular switch 1 way 6A, 1 module, complete all as specified and as directed.
S&F Modular switch, 1 way 16 Amp, 1 module, complete all as specified and as directed.
S&F Modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and as directed.
S&F Modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and as directed.
S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed.
S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/casing caping fittings, ISI marked, complete all as specified and as directed.
S&F 9 Watt LED Bulb (Non-dimmable) of Standard / Universal size, Base - B22, Power Factor > 0.90, Lamp Efficiency > 80%,, Color Temperature - 3000 K, Lumen output - 900 lm, Colour Rendering Index (CRI) > 70, Warm white (WW) / Cool Day Light (CDL), 230 V, 50 Hz AC, ISI marked, complete all as specified and as directed.
S&F Modular Fan step regulator, 120 Watt - 2 module, complete all as specified and as directed.
S&F in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 Watt 240 Volt, 50 Hz AC, ISI Marked decorative type with driver holder and LED lamp, correlated colour temperature shall be minimum 6500 degree Kelvin, including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. Make: Model “LDL-10-WW” of M/S Crompton/ Wipro Cat Part No. LL20-111-XXX-65NE3/ Cat Part No. ENDURALINEARNEOBS10WLED865SPCWH of Havells/ or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in replacement of LED mirror fitting 1x20 Watt, 6000 K, 2 feet, basic all purpose surface and wall mounted LED batten with powdered coated aluminium housing & integrated electronic driver & all accessories including connection with 2 core flexible copper cable 23/0.00076 from ceiling rose to fitting connection with following specification, complete all as specified and as directed :- (a) Lumen efficacy of system should be minimum 105 Lumen per watt. (b) Voltage operating range : 160 to 270 Volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-20. (g) CRCA pre coated housing. (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection device for 2.5 KV. (l) CRI : Minimum 80 Make: Cat Part No. ENDURALINEARNEOBS20WLED865SPCWH of Havells/ Model “LDL-20-WW” of M/S Crompton/ Cat Part No. LL20-111-XXX-65NE3/BCLSB or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in replacement of Dimmable touch LED table lamp 6 watt with 3 level adjustable brightness desk lamp with touch sensor switch with & including all standard accessories prewired and connecting up complete all as specified and directed.
S&F in replacement of bulk head energy efficient LED light fitting, 1x10 Watt, 230 Volts, surface mounted, comprising of high brightness LEDs, IP-65 protection, with & including all standard accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed. Make : Havells Cat Part No. RUGBYNEONFT10WLED860SSYM TOPC or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
Supply and Fixing Light Emitting Diode (LED) based street/ security light fitting, 35 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens per watt and a minimum system lumen output of not less than 3000 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA /polycarbonate /toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multi stranded copper conductor cable of 1100 Volt grade (ISI marked), fixed in repairs, complete all as specified and as directed.
NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
Supply and fixing in replacement mounting bracket (suitable for fixing/holding street/ security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.50m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, matching with section of Pole/suitable for wall, complete all as specified and as directed.
S&F sheet metal enclosure for distribution boards flushed in wall, double door type, suitable for fixing MCBs/MCCBs, 415 Volts with 200 Amps rated bus bar, load line DB fitted with bus bar neutral links blank plates, VTPN, 4 way, suitable for MCB, fitted complete all as specified and as directed including taking down old existing unserviceable DB with fixtures of any type & capacity :- Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F sheet metal enclosure, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 Volts, fixed in repairs, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, SPN, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCCB 4 Pole 100 Amps, Adjustable type having, breaking capacity 16 KA, 415 Volt including taking down old existing MCCB complete all as specified and directed.
Supply, assembling, hanging, fixing & testing Ceiling Fan of size 1200 mm sweep, minimum air delivery 210 CMM with service value 6.00 BEE, 5 star rated, with brushless direct current (BLDC) motor, single phase, AC supply, 230 Volt, with & including down rod, canopies, three number blades, capacitor 2.5 mfd, hook, rubber reel, safety pins, nuts, bolts, washers, cable connector and making connection with PVC insulated & sheathed 1 Sqmm three core flexible copper multistranded conductor cable (ISI marked) from ceiling rose to connector of ceiling fan including marking of SM / MES number with thick synthetic enamel paint of approved tint including taking down old ceiling and deposite to AGE store complete all as specified and as directed. Note :- The font, style & place of writing SM/ MES number with synthetic enamel paint on ceiling fan shall be as directed by the Engineer-in-Charge and cost thereof shall deemed to be included in quoted rates.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with Four runs of 10 sqmm (nominal area) size main cable & Two run of 10 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 32mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 04 runs of 10 sqmm size main cable, 02 run of 10 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 50 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes :-(i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm confirming to IS -5820 complete all as specified and as directed.
M&L for Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete including taking down old unserviceable pipe with clamps complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately.
G S BUILDERS AND ENGINEERS
M/S BUDHRAM BISHNOI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .