Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹17.9 L Quoted ₹18.6 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹22.6 L+₹4.0 L (21.2%)Rejected-Finance AZARA GUWAHATI ASSAM 781017 | KAMRUP METRO | ASSAM | 781017 | ₹22.6 L+₹4.0 L (21.2%) | L2 | Rejected-Finance Not Validated (Other than lowest bidder) |
Tender Value
Refer Docs
EMD Value
₹32,500
Closing Date
21 Sept 2022, 6:00 pmClosed
GE GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
REPAIR MAINT OF EXTERNAL ELECTRIFICATION SYSTEM AND ALLIED SERVICES AT OTHER THAN BASISTHA AREA UNDER GE GUWAHATI
2022_MES_544863_1
GE/GUW/36/8234 OF 2022-23
Open Tender
Civil Works
Item Rate
150 days
GUWAHATI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE GUWAHATI
₹32,500
Yes
31 Oct 2022
11 Aug 2022
23 Sept 2022
11 Aug 2022
21 Sept 2022
8 Sept 2022
11 Aug 2022 - 18 Aug 2022
Amount
Excavation in trenches not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables etc and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed.
Taking out old unserviceable UG cable of any size or description including taking out old brick protection complete all as directed.
M&L sand cushioning in cable trenches over & under the cable, with river washed coarse sand,(approved source) as per standard practice with proper compaction complete all as specified and directed.
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multi stranded aluminium conductor of size 50 sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multi stranded aluminium conductor of size 70 sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multi stranded aluminium conductor of size 95 sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multi stranded aluminium conductor of size 120 sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multi stranded aluminium conductor of size 150 sqmm 3½ core complete all as specified and as directed.
Supply, jointing and testing LT UG cable jointing kit for XLPE/ PVC insulated 1100 Volts grade, for outdoor heat shrinkable joint 150sqmm to 185 Sqmm , 3½ core, aluminium conductor cable with jointing material and accessories complete all as specified and directed.
Supply, jointing and testing LT UG cable jointing kit for XLPE/ PVC insulated 1100 Volts grade, for outdoor heat shrinkable joint 70sqmm to 120 Sqmm , 3½ core, aluminium conductor cable with jointing material and accessories complete all as specified and directed.
Supply, jointing and testing LT UG cable jointing kit for XLPE/ PVC insulated 1100 Volts grade, for outdoor heat shrinkable joint 25sqmm to 50 Sqmm , 3½ core, aluminium conductor cable with jointing material and accessories complete all as specified and directed.
S&F in repair 50 mm dia GI pipe ‘light grade’ with all fittings for protection of cable laid in trenches, road crossing, drain crossing, under floor or fixed to iron structures/poles complete all as specified and directed.
M&L applying two coats of syntheic enamel paint (of approved shade) on external sufraces of bus bar chamber (exposed surface area not less than 1.5Sqm) including necessary preperation of surfaces, and writing Substation No from which FPB Charged and Accomodations To Whome are Supplied from Feeder Pillar Box complete all as directed.
Dismantling of ACSR or AAC conductors of any description complete all as directed.
M & L aluminium conductor, steel reinforced (ACSR) of any size as approved on Poles including straining, binding to insulators with aluminium binding wire with connectors, etc, providing PVC sleeves for jumpers as in OH conductors complete all as specified and as directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete complete all as directed.
M & L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and as directed.
M & L stay assembly complete with all accessories such as mild steel galvanized flat iron stay clamp, 7/3.15 mild steel galvanized stay strand/ wire, one loop type porcelain vitreous insulator (white, brown or green) overall dimensions 65 X 90 mm & clearance of hole 16mm, stay grips, mild steel galvanized stay bow, thimbles, 16 mm dia mild steel galvanized stay rod and mild steel galvanized stay-plate all as shown in electrical plate No 1 of SSR Part-I including dismantling of old stay assembly complete all as specified and as directed. [Note: (i) Excavation & earthwork, cement concrete, etc. will be measured and paid separately under relevant Items of this Schedule.
M&L Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts size suitable for 1100 Volts, height 100mm, max dia 115mm, insulator bolts of dia 14mm complete all as specified and as directed.
Dismantling/taking down insulators of any type or size complete complete all as directed.
M&L steel tubular swaged poles, complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, 9.00 meter long, inclusive of one primer coat of red oxide zinc chrome primer and two coats of aluminium paint including preparation of surfaces and making strip 150mm wide in alternate layer of black and yellow syntheic enamel paint upto 1.5 metre above Coping, including dismanting old unserviceable pole, complete all as specified and as directed.(The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161) NOTE : Earthwork, cement concrete will be measured and paid seperately under appropiate items
M & L Plain cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate)as in coping of poles including all necessary formwork complete all as specified & as directed.
M&L Plain cement concrete (1:4:8) type-D2 with using 40 mm graded crushed stone aggregate as in mass concrete etc complete all as specified and as directed.
M&L for Plain cement concrete (1:3:6) type-C2 with using 40 mm graded crushed stone aggregate as in foundation for pole/stay and mass concrete etc complete all as specified and as directed.
S&F in repair, microprocessor MCCB 4 Pole, 630 Amps, 415 Volt, 36 KA complete all as specified and directed. Note: Frame size of MCCB shall be as per the existing MCCB
S&F in repair, microprocessor MCCB 4 Pole, MCCB 250 Amps, 415 Volt, 36 KA complete all as specified and directed. Note: Frame size of MCCB shall be as per the existing MCCB
S&F in repair, microprocessor MCCB 4 Pole, MCCB 200 Amps, 415 Volt, 36 KA, complete all as specified and directed. Note: Frame size of MCCB shall be as per the existing MCCB
S&F in repair, fixed thermal and fixed magnetic 4 Pole MCCB 125 Amps, 415 Volt, 16 KA complete all as specified and directed. Note: Frame size of MCCB shall be as per the existing MCCB
S&F in repair, fixed thermal and fixed magnetic 4 Pole MCCB 100 Amps, 415 Volt, 16 KA complete all as specified and directed. Note: Frame size of MCCB shall be as per the existing MCCB
S&F in repair, fixed thermal and fixed magnetic 4 Pole MCCB 63 Amps, 415 Volt, 16 KA complete all as specified and directed. Note: Frame size of MCCB shall be as per the existing MCCB
S&F factory made outdoor Bus bar chamber of size 600 mm (H) x 500 mm (W) x 300mm (D) , 4 Strip aluminum busbar of 320 Amps rating for Phase and Neutral, 400mm long dully fixed on procelain insulator, made out of 3.15mm thick thick MS Sheet and with proper weather protection (rain protection canopy) having four legs with with angle iron 80mm x 80mmx5mm thick on floor with PCC foundation 250mm x 150mm x 150mm using Type B1 (1:2:4) (20mm graded crushed aggregate), dully powder coated paint having two parts, front opening door including earth terminal point including provision of 01 Nos, MCCB 100 Amps, 4 Pole, 16KA , cable connection including taking down/dismantling unserviceable bus bar complete all as specified and as directed.
M&L Earthing with Galvanised Steel Earth Plate Electrode 600x600x6 mm thick, buried directly in ground vertically to a depth not less than 2.25 METRE below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 METRE below normal ground level, connected to GI Earth Strip 25 x 4 mm drawn through and including GI Pipe 32 mm bore (dia) ‘light grade’ for protection upto 1.00 METRE above the Floor Level of the Building where Main Switch/DB situated, by means of Bolts, Nuts, Check Nuts and Washers etc., Earth Plate surrounded by a packed thickness of Char Coal or coke dust mixed with common Salt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6 (20 mm graded aggregate) and Pre-cast RCC 1:2:4 (20mm graded aggregate) Cover Slab 350x350 x50mm, reinforced with and including 8.0 mm dia TMT Bars @ 100 mm centre to centre both ways, GI wire mesh, Funnel with GI Watering Pipe 20mm bore (dia) ‘medium grade’, necessary excavation in soft/loose soil, returning, filling in and removal of Surplus Spoil upto a distance of 50 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion, including necessary dismantling the unserviceable earthing complete all as specified and as directed.
M/s Torrent Inc
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .