Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹36.4 L+₹4.1 L (12.6%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 3 | L3₹37.8 L+₹5.5 L (17.0%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 4 | L4₹38.5 L+₹6.2 L (19.3%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 5 | L5₹40.1 L+₹7.8 L (24.1%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST BIDDER |
| Sl No | Description | Qty | Unit | H C CONSTRUCTION L2 | PANKAJ AND BROTHERS L3 | M/s BHAGIRATH INFRA & ALLIED WORKS L1 | M/S IQRA CONSTRUCTION L5 | M/s RAAJSHREE INFRA L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for cutting the edges of existing joints with suitable machine by racking out old sealing compound from existing joints of tarmac of size 8mm to 12mm wide and 25mm deep and as directed by special tools like cutting blades / grinder machines (use of hammers is prohibited as it damages the edges) and removing old filled sealing compound from the joints by means of compressed air using hand blower including disposal of the same to a distance of 500m from the edge of runway as directed and repair of joints by epoxy wherever required and fill the joints by mechanical means as per following process: -
(i) Provision of Backup rod of 10mm dia suitable to be inserted in the joint tightly as specified.
(ii) Provision of adequate masking tape on either sides of joint to avoid spillage on concrete surface before applying joint sealant and removing the same after sealing of joints.
(iii) Supplying and filling of sealing compound properly for a depth of 15mm as specified after application of suitable primer as directed by Engineer-in-Charge.
(The finished level of sealed joints shall be on an average 3 mm below the top surface of slabs.)
NOTE: - Sealing compound shall be Bostik "Seal N flex -2k', 02 component (Base and Hardner) Bostik Polyurethane sealent of grey colour conforming to BS-5212 with minimum movement accommodation factor of + 30% when tested as per ASTM C-719 or equivalent product of M/S Choksey Chemicals Pvt. Ltd. or M/S STP Ltd as approved by GE in writing. The sealent shall have shore A @ 25 degree centigrade =15 + 5 and as per manufacturer's instructions. | 14 | 10 RM | 2,150 ₹30,100 Lowest | 2,290 ₹32,060 | 2,200 ₹30,800 | 2,200 ₹30,800 | 2,800 ₹39,200 |
| 2.00 | Ditto all as per item No 01 here-in-before but joints of width 14mm to 18mm and 28 mm deep (alongwith 12 mm dia backup polyethylne rod. | 17 | 10RM | 2,350 ₹39,950 Lowest | 2,380 ₹40,460 | 2,600 ₹44,200 | 2,400 ₹40,800 | 2,900 ₹49,300 |
| 3.00 | Ditto all as per item No 01 here-in-before but joints of width 20mm to 25mm and 45 mm deep alongwith 30 mm dia backup polyethylne rod | 7 | 10RM | 2,650 ₹18,550 | 2,395 ₹16,765 Lowest | 2,900 ₹20,300 | 2,800 ₹19,600 | 3,500 ₹24,500 |
| 4.00 | Ditto all as per item No 01 here-in-before but joints of width 08mm to 12mm and 25 mm deep (alongwith 10 mm dia backup polyethylne rod)
NOTE: - Sealing compound shall be Bostik "Seal N flex -Premium P 795', Bostik Polyurethane sealent of grey colour conforming to BS-5212 with minimum movement accommodation factor of (+ -) 50% when tested as per ASTM C-920 & ASTM C1248 or equivalent product of M/S Choksey Chemicals Pvt. Ltd. or M/S STP Ltd. as approved. The sealent shall have shore A hardness >/= 35 and as per manufacturer's instructions. | 220 | 10RM | 2,550 ₹5,61,000 | 2,295 ₹5,04,900 | 2,200 ₹4,84,000 Lowest | 2,500 ₹5,50,000 | 2,800 ₹6,16,000 |
| 5.00 | Ditto all as per item No 04 above but joints of width 14mm to 16mm and 28 mm deep alongwith 12 mm dia backup polyethylne rod | 420 | 10RM | 2,750 ₹11,55,000 | 2,320 ₹9,74,400 Lowest | 2,400 ₹10,08,000 | 2,850 ₹11,97,000 | 3,000 ₹12,60,000 |
| 6.00 | Ditto all asper item No 04 above but joints of width 20mm to 25mm and 45 mm deep alongwith 30 mm dia backup polyethylne rod | 80 | 10RM | 2,850 ₹2,28,000 | 2,420 ₹1,93,600 Lowest | 2,800 ₹2,24,000 | 3,300 ₹2,64,000 | 3,800 ₹3,04,000 |
| 7.00 | M & L for filling of pot holes of size 20mm dia and 20mm deep in concrete surface sand filling shall be done as per following process:-
(i) Cleaning of surface by means of wire brush and removing all the dust by means of compressed air.
(ii) Bostik ERM or equivalent product of M/S Choksey Chemicals Pvt. Ltd. or M/S STP Ltd as approved by GE in writing epoxy resin mortar as per manufacturer's instructions after application of epoxy resin primer with and including all necessary form work complete all as specified and directed. | 500 | Each | 48 ₹24,000 Lowest | 150 ₹75,000 | 55 ₹27,500 | 70 ₹35,000 | 60 ₹30,000 |
| 8.00 | M & L for repair to concrete slab or pavement of existing damaged edges / spoiled edges to triangular / rectangular cross section,of width 15mm to 20mm and depth 30mm to 40mm , by machine cutting and removing all broken and loose material to a distance exc. 50 metres but not exc. 100 metres and cleaning the surface with compressed air to remove all dust, dirt, loose sand / foreign material, washing the surface with acid solution and repairing surface / edges with Bostik ERM or equivalent product of M/S Choksey Chemicals Pvt. Ltd. or M/S STP Ltd as approved by GE in writing epoxy resin mortar as per manufacturer's instructions after application of epoxy resin primer with and including all necessary form work complete all as specified and directed. | 500 | RM | 290 ₹1,45,000 | 590 ₹2,95,000 | 280 ₹1,40,000 Lowest | 350 ₹1,75,000 | 350 ₹1,75,000 |
| 9.00 | M & L for cutting the edges of any type of joints of width 8mm to 10mm and 30 mm deep by racking out old sealing compound from existing joints by means of compressed air and filled the joints with sealing compound grade 'B' after application of primer complete all as specified and directed. | 150 | 10 RM | 440 ₹66,000 | 1,090 ₹1,63,500 | 400 ₹60,000 Lowest | 700 ₹1,05,000 | 500 ₹75,000 |
| 10.00 | S&F in repair visible sign board of area/size exceeding 1.80 sqm but not exceeding 3.15sqm each made from 5.00 mm thick engineering grade plastic (acralic Sheet) having monolithic structure to with stand,temperature variations from cold environment to sweltering hot condition sand to with stand high velocity winds,framed and braced with 50mm dia PVC pipe best qualty to with standhigh velocity wind pressure,with height of bottom of board should be 45-60 cm above the ground level with best quaility structure including providing and applying weather resistance coating,providing and pasting of new numerals/alphabets with retro reflective tape cutting on it as computer plotter etc with & including LED light provisioning for illumination complete all as specified and directed | 13 | Each | 30,000 ₹3,90,000 | 29,900 ₹3,88,700 Lowest | 30,000 ₹3,90,000 | 35,000 ₹4,55,000 | 35,000 ₹4,55,000 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
28 Nov 2025, 6:00 pmClosed
GE (AF) BKT
GE (AF) BKT, LUCKNOW
REPAIR TO PLINTH, JOINT CRACK REPAIR TO SIGN BOARD AND CONNECTED E/M REPAIRS OF AIR FILED AREA AT AF STN BKT
2025_MES_739001_1
8827/BKT/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BKT
7 documents required · 7 mandatory
₹500
GE (AF) BKT
₹80,000
14 May 2026
8 Nov 2025
1 Dec 2025
8 Nov 2025
28 Nov 2025
22 Nov 2025
Amount
M & L for cutting the edges of existing joints with suitable machine by racking out old sealing compound from existing joints of tarmac of size 8mm to 12mm wide and 25mm deep and as directed by special tools like cutting blades / grinder machines (use of hammers is prohibited as it damages the edges) and removing old filled sealing compound from the joints by means of compressed air using hand blower including disposal of the same to a distance of 500m from the edge of runway as directed and repair of joints by epoxy wherever required and fill the joints by mechanical means as per following process: - (i) Provision of Backup rod of 10mm dia suitable to be inserted in the joint tightly as specified. (ii) Provision of adequate masking tape on either sides of joint to avoid spillage on concrete surface before applying joint sealant and removing the same after sealing of joints. (iii) Supplying and filling of sealing compound properly for a depth of 15mm as specified after application of suitable primer as directed by Engineer-in-Charge. (The finished level of sealed joints shall be on an average 3 mm below the top surface of slabs.) NOTE: - Sealing compound shall be Bostik "Seal N flex -2k', 02 component (Base and Hardner) Bostik Polyurethane sealent of grey colour conforming to BS-5212 with minimum movement accommodation factor of + 30% when tested as per ASTM C-719 or equivalent product of M/S Choksey Chemicals Pvt. Ltd. or M/S STP Ltd as approved by GE in writing. The sealent shall have shore A @ 25 degree centigrade =15 + 5 and as per manufacturer's instructions.
Ditto all as per item No 01 here-in-before but joints of width 14mm to 18mm and 28 mm deep (alongwith 12 mm dia backup polyethylne rod.
Ditto all as per item No 01 here-in-before but joints of width 20mm to 25mm and 45 mm deep alongwith 30 mm dia backup polyethylne rod
Ditto all as per item No 01 here-in-before but joints of width 08mm to 12mm and 25 mm deep (alongwith 10 mm dia backup polyethylne rod) NOTE: - Sealing compound shall be Bostik "Seal N flex -Premium P 795', Bostik Polyurethane sealent of grey colour conforming to BS-5212 with minimum movement accommodation factor of (+ -) 50% when tested as per ASTM C-920 & ASTM C1248 or equivalent product of M/S Choksey Chemicals Pvt. Ltd. or M/S STP Ltd. as approved. The sealent shall have shore A hardness >/= 35 and as per manufacturer's instructions.
Ditto all as per item No 04 above but joints of width 14mm to 16mm and 28 mm deep alongwith 12 mm dia backup polyethylne rod
Ditto all asper item No 04 above but joints of width 20mm to 25mm and 45 mm deep alongwith 30 mm dia backup polyethylne rod
M & L for filling of pot holes of size 20mm dia and 20mm deep in concrete surface sand filling shall be done as per following process:- (i) Cleaning of surface by means of wire brush and removing all the dust by means of compressed air. (ii) Bostik ERM or equivalent product of M/S Choksey Chemicals Pvt. Ltd. or M/S STP Ltd as approved by GE in writing epoxy resin mortar as per manufacturer's instructions after application of epoxy resin primer with and including all necessary form work complete all as specified and directed.
M & L for repair to concrete slab or pavement of existing damaged edges / spoiled edges to triangular / rectangular cross section,of width 15mm to 20mm and depth 30mm to 40mm , by machine cutting and removing all broken and loose material to a distance exc. 50 metres but not exc. 100 metres and cleaning the surface with compressed air to remove all dust, dirt, loose sand / foreign material, washing the surface with acid solution and repairing surface / edges with Bostik ERM or equivalent product of M/S Choksey Chemicals Pvt. Ltd. or M/S STP Ltd as approved by GE in writing epoxy resin mortar as per manufacturer's instructions after application of epoxy resin primer with and including all necessary form work complete all as specified and directed.
M & L for cutting the edges of any type of joints of width 8mm to 10mm and 30 mm deep by racking out old sealing compound from existing joints by means of compressed air and filled the joints with sealing compound grade 'B' after application of primer complete all as specified and directed.
S&F in repair visible sign board of area/size exceeding 1.80 sqm but not exceeding 3.15sqm each made from 5.00 mm thick engineering grade plastic (acralic Sheet) having monolithic structure to with stand,temperature variations from cold environment to sweltering hot condition sand to with stand high velocity winds,framed and braced with 50mm dia PVC pipe best qualty to with standhigh velocity wind pressure,with height of bottom of board should be 45-60 cm above the ground level with best quaility structure including providing and applying weather resistance coating,providing and pasting of new numerals/alphabets with retro reflective tape cutting on it as computer plotter etc with & including LED light provisioning for illumination complete all as specified and directed
Ditto all as per item No 10 above but area not exceeding 0.80 sqm each complete all as specified and directed.
M&L for preparation of old painted surface of any description over 10cm width or girth of concrete/plastered surface and applying one coat of synthetic enamel paint on signal square, wind sock at any height etc complete all as specified and directed.
Demolition of cement Concrete surfaces of any description and in any position not other wise specifically provided for pavement of taxi track / runway / Dispersal area complete all as specified and directed.
M&L for M-35, design mix cement concrete work using crushed stone aggregate in path/hard-standing of minimum flexural strength 40kg/per square centimetre in field by using cement not less than 400kg Cum, thickness of concrete should be 25cm or less, complete all as specified and directed. Note: -(i) Cement shall be provided as per approved design mix but not less than 400kg/Cum.(ii) In the event of increase in cement content as per design mix formula, nothing extra shall be admissible & quoted rates are deemed to includes for the same. (Note: Concrete shall be procured from RMC-M35 design mix.)
Taking down cement plaster from brick walls/stone walls brick of drain channel etc of any description including racking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for rendering 10mm thick Cement mortar (1:4) on concrete surfaces,/brick of drain channel finished even and smooth without using extra cement on concrete/brick surfaces, complete all as specified and directed
Demolition of brick work/stone boulder masonry,built in cement mortor including all quions,arches, pillars etc remaining the same exceeding 250 m but not exceeding 500m and depositing where directed complete all as specfied and directed.
M&L for Brick work with old size fly ash bricks straight or curved on plan exceeding 6m mean radius and setting in cement mortar (1:6) complete all as specified and directed.
M& L for rendering of external surface 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces including uprooting/cutting of vegetation growth (maximum height upto three stories) complete all as specified and directed (Note:- Below 10 Sqm Qty be excuted throuth conventional method).
M & L for single component 'Aspha Flo' coal tar free signature grade Gilsonite modified Asphalt emulsion, special polymers and Adhesive streaming crack, joint stuffer to prevent cracks from forming into pot holes and filling of cracks and joints on asphaltic surface of the runway which shall be complete to be applied directly on damp pavement also and coverage shall be 24.20 m/Ltr for 6mm (width) x 6mm (depth) crack including gilsonite modified asphalt emulsion (applied as per manufactures instructions complete all as specified and directed. (Note :- Emulsion shall be measured & paid seperately)
Ditto all as per above item No. 20 but for size of crack 13mm x 13mm and coverage 6.05m/Ltr complete all as specified and directed. (Make: M/S Srijan Systems Pvt Ltd or equivalent make as approved by GE in writting.
M&L for cement concrete in surface channels and drains, or any other type using PCC (1:2:4) type B-1 using 20mm graded stone aggregate and surface finished even and smooth without using extra cement complete all as specified and directed.
Servicing, cleaning of tower air conditioner 2.0 Ton capacity at site, cleaning of equipment by applying blower, water pressure Jet machine to remove the complete dust, cleaning of drain line to resolve the issue of leakage all the components with suitable cleaning agent, combing the condenser coil for better efficiancy complete all as specified and directed.
Servicing, cleaning of flame proof air conditioner 1.5/2.0 Ton capacity at site, cleaning of equipment by applying blower, water pressure Jet machine to remove the complete dust, cleaning of drain line to resolve the issue of leakage all the components with suitable cleaning agent, combing the condenser coil for better efficiancy complete all as specified and directed.
Servicing, cleaning of Fan coil type air conditioner 1.5/2.0 Ton capacity at site, cleaning of equipment by applying blower, water pressure Jet machine to remove the complete dust, cleaning of drain line to resolve the issue of leakage all the components with suitable cleaning agent, combing the condenser coil for better efficiancy complete all as specified and directed.
Servicing, cleaning of window /split air conditioner (indoor and outdoor unit complete) 1.5/2.0/3.0 Ton capacity at site, cleaning of equipment by applying blower, water pressure Jet machine to remove the complete dust, cleaning of drain line to resolve the issue of leakage all the components with suitable cleaning agent, combing the condenser coil for better efficiancy complete all as specified and directed.
Repair/ maintenance of window /split type air conditioner 1.5/2.0/3.0 Ton capacity at site,checking the wiring, starting/running capacitor, staring relay, overload relay, thermostat switches condensor motor,blower motor,swing motor ,blower/condensor fan/ removal of defactive parts and rectification of fault,Top Up/charging of gas at required pressure for proper cooling, connecting and testing on load complete all as specified and directed. NOTE;- (i) Defective parts/Gas (refrigerant) shall be measured and paid seperately as 'Supply Only' under respective item of Sch "A" given here-in-after. (ii) Complaints have to attend on day to day basis and regular visit of adequate mechanic during contract period to maintain above Nos appliances at the Stn in tech and as well as Adm area. (iii) Payment for each job shall be made once only during currency of contract irrespective of attending / replacing defective parts at any time that will be paid supply only under respective item if not paid earlier. (iv) complaint for non function of ACs have to attend on same day and normal defects have to rectify within 24 hours ,major defects have to rectified within 4 days otherwise recovery shall be made @ 500/ day of delay. (v) If required and repair is beyond at site taking out & refixing of AC / any repair shall be deemed to include in quoted rate. (i) The servicing/ cleaning/ Repair/ maintanence of ACs to be carried out by third party professional service agency like urban clap etc.hiered by contractor who have not their own workshop (repair centre) of refrigeration and air conditioning. (ii) service provider to sign MoU with contractor and detais of MoU to be submitted to GE before commencement of work. (iii) At any point of time if performance of service provider is found Unsatisfactory in opinion of GE the MoUis subjected to cancle immediately and fresh MoU with diffarent service provider to place within 10 Day otherwise recovery shall be made @ Rs.550 per Day of delay
Supply only R-22/R-32/R- 410 or required refrigerant in the Air conditioner to be repaired in Sch-A item No.27 of testing to the cooling appliances complete all as specified and directed.
Supply only condenser fan motor suitable for spit AC of 1.5/2.0 TR capacity AC of existing make.complete all as specified and directed.
Supply only condenser fan motor suitable for spit AC of 3.0 TR capacity AC of existing make complete all as specified and directed.
Supply only condenser fan blade suitable for spit AC of 1.5/2.0 TR capacity AC complete all as specified and directed.
Supply only condenser fan blade suitable for spit AC of 3.0 TR capacity AC complete all as specified and directed.
Supply only of indoor blower fan motor suitable for split type AC of 1.5/2.0 TR capacity of existing make with supper enameled copper winding fixing and testing on load complete all as specified and directed.
Supply only of indoor blower fan Assembly suitable for split type AC of 1.5/2.0 TR capacity & make of existing make complete all as specified and directed.
Supply only of indoor blower fan Assembly along with fan motor suitable for split type AC of 3.0 TR capacity & make of existing make complete all as specified and directed.
Supply only running capacitor of 36-60 MFD complete all as specified and directed
supply only condenser fan motor capacitor of capacity 4.0 mfd / 6.0 mfd suitable for existing window type/ outdoor unit of split type air conditioner of capacity upto 2.0 TR complete all as specified and as directed. Make:Sarda/Unistar/Tibcon/Asian/Epcos.
supply only New Remote and PCB sensor unit assembly suitable for existing make of window / split type air conditioners non inverter model of capacity upto 2.0 TR complete all as specified and directed.
Supply only Indoor circuit board PCB of inverter type Split AC of Make : Daikin/LG/Voltas/Blue star as existing at site of capacity 1.5/2.0 TR Split type A/C complete all as specified and directed.
Supply only outdoor circuit board PCB of inverter type Split AC of Make : Daikin/LG/Voltas/Blue star as existing at site of capacity 1.5/2.0 TR Split type A/C complete all as specified and directed.
Supply only Indoor/outdoor circuit board PCB Split AC of Make : Daikin/LG/Voltas/Blue star as existing at site of capacity 3.0 TR Split type A/C complete all as specified and directed.
Repair/Maintanence of Cuircuit board PCB suitable for existing make of window / split type air conditioners non inverter model of capacity upto 3.0 TR complete all as specified and directed.
Supply only single phase contactor 240 volt, 25 Amp for split type AC 1.5/2.0 TR complete all as specified and directed.
Dismantling / taking out unserviceable burnt sealed compressor unit of capacity 1.5/2.0/3.0 TR from air conditioner and fixing only hermetically sealed rotary type compressor unit of any capacity including necessary brazing the same with existing refrigerant pipe, supply and charging refrigerant gas including testing complete all as specified and directed Note: (i) Hermetically Sealed compressor shall be measured and paid separately under supply only items given here-in-before. (ii) Suitable refrigerant gas shall be measured and paid seperately as 'Supply Only' under respective item of Sch "A" given here-in-after
Supply only hermetically sealed rotary type compressor unit of capacity 1.5 TR complete all as specified and directed.
Supply only hermetically sealed rotary type compressor unit of capacity 2.0 TR complete all as specified and directed.
Supply only hermetically sealed rotary type compressor unit of capacity 3.0 TR complete all as specified and directed.
Taking down unserviceable condensing coil unit and supply and fix new copper condensing coil unit suitable for split type AC of capacity of 1.5 TR, as per the existing, including brazing the suction / discharge lines and filling the suitable refrigerant gas and testing complete all as specified and directed. Note : Refrigerant gas shall be measured and paid seperately as 'Supply Only' under respective item of Sch "A" given here-in-before
Taking down unserviceable condensing coil unit and supply and fix new copper condensing coil unit suitable for window / split type AC of capacity of 2.0TR, as per the existing, including brazing the suction / discharge lines and filling the suitable refrigerant gas and testing complete all as specified and directed. Note : Refrigerant gas shall be measured and paid seperately as 'Supply Only' under respective item of Sch "A" given here-in-before
Taking down unserviceable condensing coil unit and supply and fix new copper condensing coil unit suitable for window / split type AC of capacity of 3.0TR, as per the existing, including brazing the suction / discharge lines and filling the suitable refrigerant gas and testing complete all as specified and directed. Note : Refrigerant gas shall be measured and paid seperately as 'Supply Only' under respective item of Sch "A" given here-in-before
H C CONSTRUCTION (BID ID -3482630)
PANKAJ AND BROTHERS (BID ID -3484530)
M/s RAAJSHREE INFRA (BID ID -3483623)
M/S IQRA CONSTRUCTION (BID ID -3485150)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_827484.xls
BOQ • 0.59 MB
8827tenderdocuments.pdf
Tender Documents • 1.41 MB
8827credit.pdf
Additional Documents • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .