| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC 35 P C MUKHERJEE STREET PO KONNAGAR DIST HOOGHLY PIN 712235 | KONNAGAR | HOOGHLY | WEST BENGAL | 712235 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹48.2 L+₹3.7 L (8.38%)Rejected-AOC P 21 MANAS BAG KOLKATA 700 056 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700056 | L2 | Rejected-AOC other than lowest bidder | |
| 3 | L3₹48.4 L+₹3.9 L (8.83%)Rejected-AOC 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L3 | Rejected-AOC other than lowest bidder | |
| 4 | L4₹48.7 L+₹4.2 L (9.48%)Rejected-AOC | L4 | Rejected-AOC other than lowest bidder | |
| 5 | L5₹48.9 L+₹4.4 L (9.94%)Rejected-AOC ADARSHAPARA EAST BIDYADHARPUR SHYAMNAGAR DIST 24 PARGANAS N PIN 743 127 | SHYAMNAGAR | 24 PARGANAS N | WEST BENGAL | 743127 | L5 | Rejected-AOC other than lowest bidder |
Tender Value
₹58.6 L
EMD Value
₹1.1 L
Closing Date
19 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (S) Barrackpore
Commander Works Engineers (Sub) Military Engineer Services PO Barrackpore, Dist 24 Pgns (N) Kolkata 700120 (W.B)
SPL REPAIR TO BLDG NO. PB - 01 (OR SINGLE ACCN) FOR MT AND SHGD PLATOON AT 17 CORPS OMC UNDER GE (N) KOLKATA
2023_MES_599073_1
CWE/(N) KOL/06 of 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (North) Kolkata
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹1.1 L
Yes
22 Jul 2023
27 May 2023
21 Jun 2023
27 May 2023
19 Jun 2023
12 Jun 2023
Amount
Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc. complete all as specified and as directed.
Material and labour for brick work with bricks class designation 75, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Material and labour for brickwork with bricks class designation 75, old size, straight or curved on plan exc 6m mean radius in half brick thick wall built in CM (1:4) complete all as specified and directed.
Demolition of reinforced cement concrete of roofs, floors , staircases, landing, chajjas and similar suspended works in ground floors beams(reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Demolition of reinforced cement concrete of roofs, floors (other than ground floors) beams, staircases, landing, chajjas and similar suspended works (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Material and labour for RCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies canopies, deck slabs and in shelves and the like.
M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work; not exceeding 200mm thick ( horizontal or sloping) all as specified and directed.
M&L formwork to edges of concrete flats,treads,breaks in floor, window cills, concrete railings and similar work; exc 5cm but not exc 10cm wide, all as specified and directed.
Material and labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending lapping etc as required and welding with existing bar complete all as specified and as directed
Material and labour for mild steel TMT bars 6 to 8mm bar, cut to length, bent to shape required, including cranking, bending, lapping etc as required and welding with existing bar complete all as specified and as directed.
Supply and fix 2nd class hard wood , plain, solid , straight chowkhats and frames, wrought, framed, rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and as directed.
Materials and labour for treating back of chowkhats etc with tar or coal tar black paint, area tarred exceeding 0.10 sqm but not exceeding 0.50 sqm each complete all as specified and as directed.
Material and labour 2nd class hard wood sectional area exc 6 sqcm & n.exc 13sqcm, plain, fillets, square, rectangular or triangular in section ,clean sawn, bull nosed ,chamfered or rounded on one edge or face secured with nails/screw complete all as specified and as directed.
Material and labour 2nd class hard wood sectional area exc 3sqcm & n.exc 6sqcm, plain, fillets, square, rectangular or triangular in section ,clean sawn, bull nosed ,chamfered or rounded on one edge or face secured with nails/screw complete all as specified and as directed.
Supply and fix in repairs pre laminated particle board 18/19 mm thick, interior grade one side decorative choice lamination and other side balancing white lamination fixed in cup boards shutters with 6mm thick teak wood lipping/edging all round complete all as specified and as directed.
S&F 30mm width stainless steel Continous (piano) hinges, bright finish and all as specified and directed.
Supply and fix 100mm aluminium anodised hasp and staple including bolt to hinge plate and fixed with screw and all as specified and directed.
Supply and fix 100mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Taking down cement plaster of any description on brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Material and labour for 20mm thick plaster in cement mortar (1:4) in two layers, i.e 10mm thick in each layer, top layer mixed with integral water proofing liquid admixture as per manufacturers instruction on brick or concrete surfaces of wall finished the surface fair and even complete all as specified and as directed. Note :- WPC shall be measured and paid separately.
Supply only integral water proofing liquid admixture for concrete and mortar (Make :CONPLAST X421IC of Fosroc /SIKA No 1 of SIKA/equivalent brand of PIDILITE)
Material and labour for rendering 15mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 5 mm thick plastering in CM (1:3) on concrete surfaces as in sides of column, lintel, beam, chajja, facia, railing, RCC shelves etc including finish the surface even and fair without using extra cement complete all as specified and as directed
Material and labour for 5 mm thick plastering in CM (1:3) on ceiling including finish the surface even and fair without using extra cement complete all as specified and as directed
Taking out old unserviceable floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed
Roughnening surface of old concrete floor by picking ,sweeping clean and washing down with water to remove dust ,etc complete all as specified and directed.
M&L for 40mm thick cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) in floor all as specified and directed.
Material and labour for Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but n.exc. 0.18 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM(1:6) complete all as specified and as directed.
Material and labour for glazed ceramic colour tiles 300x450 x 7mm thick as in skirting/dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Supply and fix in repair one pieced-white wash basin without pedestal 550 X 400 (oval/square pan) a/w brackets / MS nuts and bolts for fixing; fixed with and incl 32mm dia brass CP waste coupling and connecting waste pipe etc complete all as specified and directed.
Supply and fix in repair 15mm PVC connection of length 600mm with PTMT nuts of superior quality complete all as specified and directed.
S&F in repair CP Pillar taps 15 mm dia, cast copper alloy , with capstan heads, chromium plated , screwed down high pressure ,with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
Supply and fix in repair angular stop cock of 15mm bore fancy type, chromium plated with long shank and cup cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule complete all as specified and directed.
Supply and fix in repair bib taps of 15mm bore fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule complete all as specified and directed.
Supply and fix in repair brass chromium plated shower rose of 125mm size fixed in 15 mm dia pipe all as specified and directed.
Supply and fix in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including 'P'or 'S' trap (excluding flushing cistern and flush pipe) including provision of lime concrete bedding complete all as specified and as directed
Supply and fix in repair 10 litre capacity PVC valve less, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC. 32 mm dia for low level cistern including PVC connections 15mm size with PTMT nuts and washer both side of length 600mm cocomplete all as specified and directed.
Supply and fix in repair Rotational moulded polyethylene water storage tanks (multi layer) 1000 Ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
Supply and fix in repairs grating doom 125mm dia of PTMT (Minimum wt 25 Gms) complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections, segregating serviceable pipe for reuse complete all as specified and directed.
All as per item No. 40 above but 20mm bore.
Supply and fix 15 mm bore GI tube , medium grade with all fittings fixed complete to walls and ceilings or laid in floors complete all as specified .
All as per item No-42 above but 20 mm bore .
All as per item No-42 here in before but fixing only ( serviceable pipe obtained from item No-40 shall be reused )
All as per item No-43 here in before but fixing only ( serviceable pipe obtained from item No-41 shall be reused )
Supply and fix in repair Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed.
Supply and fix in repair chromium plated towel rail of 20 mm dia, D type, 600mm long between flanges fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed.
Taking down chowkahts or frames with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each complete all as specified and as directed.
Taking down chowkahts or frames with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and as directed.
Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each complete all as specified and directed.
Fixing only of shutters of any description exceeding 1 Sqm each and not exceeding 2 Sqm with old serviceable builders hard ware articles / with new builders hard ware articles if any. (Old serviceable shutter obtained from item No 50 shall be reused).
Supply and fix 35mm thick 2nd class hard wood factory made plain framed panelled door shutters, (two panel) with lock rail and panel of 12mm veneered particle board with commercial veneered on both faces and rail and stiles as per IS 1003(Pt-I), kiln seasoned and chemically pressure treated etc. complete all as specified and as directed.
Supply and fix 35mm thick 2nd class Hard wood factory made glazed and skeleton door shutters, open rebated and prepared to received glass/gauge etc (without sash bars) edges of framing plain, chamfered or rounded and mitred , beads for securing glass etc the size of member of shutter as specified in SSR Part-I, clause 8.24 (a) complete all as specified and as directed.
Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube with EPDM gasket as per specification and drawing complete all as specified and as directed.
Supply and fix factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, as per specification and drawing complete all as specified and as directed.
Supply and fix factory made solid PVC moulded door shutter 28 to 30 mm thick (stiles)with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on back face ,with particle board core ,supplying and fixing in frame at site as per specification and drawing complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) for fixing of hold fasts block and similar work including necessary form work complete all as specified & directed.
Supply and fix mild steel work as in hold fast or similar article conforming to Fe-410-0 or Fe-310-0 including tarring and sanding complete all as specified and as directed.
Supply and fix 100 mm size butt hinges, medium weight, stainless steel and fixed complete all as specified and as directed.
Supply and fix 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed.
Supply and fix 150mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Supply and fix 150mm size extruded aluminum alloy handle fabricated type anodized (ISI Marked) complete all as specified and as directed.
Supply and fix powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
Supply and fix aluminium powder coated glazed or gauged shutter for sliding window(2 or 3 track) with aluminium channel section weighing not less than 0.55 kg per sqm including aluminium channel,including all necessary fittings such as rollar, joining cleats, glazing clips, rubber packing aluminium screw as required etc complete all as specified and as directed. (Note:Wiremess/ glass shall be measured and paid separately)
Supply and fix powder coated anodised aluminium glass louver /ventilators with blades of 10mm heavy duty with lever handle etc complete all as specified and directed.(Note- Glass shall be measured and paid separately)
Supply and fix 3mm thick frosted glass ordinary quality, glazing with oil putty in square not exceeding 0.5 Sqm in each pane fixed to steel frame complete all as specified and as directed.
Supply and fix stainless steel wire cloth of 0.36 mm nominal dia of wire and averaging of width of aperture 1.40mm, fixed with stainless steel wire staples complete all as specified and as directed.
Supply and fix 3mm thick sheet glass in repairs of ordinary quality and glazing with oil putty /wooden beadings in square n. exc 0.5 sq. m in each pane and complete all as specified and as directed
Supply and fix in repairs stainless steel wire cloth of 0.36 mm nominal dia of wire and averaging of width of aperture 1.40mm, fixed with stainless steel wire staples complete all as specified and as directed.
Supply and fix in repairs 3mm thick sheet glass in repairs of ordinary quality and glazing with oil putty in square n. exc 0.5 sq. m in each pane and complete all as specified and as directed
Material and labour for cementitious grouts mixed with admixture around water spouts, CI pipes / PVC pipes of any dia complete all as specified and as directed. (Make : Cebex 100 of Fosroc/Intraplast EP of SIKA/ or equivalent brand of PIDILITE)
Supply and fix in repair UPVC (SWR) pipe 110 mm bore,single socketed, in any length with rubber ring joints fixed to walls with and including PVC clip complete all as specified and directed.
Supply and fix in repair UPVC(SWR) bend 110 mm dia complete all as specified and directed.
Supply and fix in repair UPVC(SWR)branch piece, single T equal or unequal 110 mm dia complete all as specified and directed.
Dismantling cast iron drain pipes jointed in cement mortar obtained either from trenches/wall as required complete all as specified and as directed.(Note : Excavation if required, shall be measured and paid separately)
Supply and fix 100mm bore cast iron (Sand cast pipes) soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and as directed.
Supply and fix 100mm bore cast iron (Sand cast pipes) soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall with MS clamp complete all as specified and as directed.
Supply and fix 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and as directed
Supply and fix 100mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and as directed.
Supply and fix 100mm bore cast iron cowls complete all as specified and as directed.
Material and labour for complete removal of existing treatment on plastered surfaces of walls including washing, rubbing down and stopping of old treatement and applying two coats of cement base paint over a coat of cement primer complete all as specified and as directed.
Material and labour for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of cement primer complete all as specified and as directed.
Material and labour for applying one coat of synthetic enamal paint to wooden surface exceeding 10cm width or girth including preparation of old painted wooden surfaces complete all as specified and as directed.
Material and labour for applying one coat of synthetic enamal paint on steel surface of any description over 10cm widht or girth including preparation of old painted surfaces complete all as specified and as directed.
Complete removal of existing treatment of wall including washing, rubbing down and stopping of old treatement and material and labour for applying 1.50mm thik wall care putty and applying two coats of oil bound distemper over a coat of alkali resistant primer to wall complete all as specified and as directed.
All as per item No.86 above but in ceiling.
M&L for applying 1.5mm thick wall care putty and applying two coats of oil bound distemper over a coat of alkali resistant primer to wall to new plaster surface complete all as specified and as directed.
All as per item No.88 above but in ceiling.
Material and labour for two coats of synthetic enamel paint over a coat of pink primer to new wooden surfaces of any description over 10cm width or girth including preparation of new surfaces complete all as specified and as directed.
Taking down pelmet boxes and supply & fix Decorative /Fancy type curtain rods of length not exceeding 1.5 m of powder coated Aluminium suitable of 25 mm dia alongwith fancy brackets and nec fixtures complete all as specified and directed
M&L for 20-25mm thick prepolished single piece kota stone flooring over 20mm thick screed bed in CM (1:4) on treads/riser of steps all as specified and directed.
Demolition of cement concrete of any description and in any position provided as in roof padding, roof curb etc including debris/retrieved materials disposed off out of MoD land as directed and complete all as specified and as directed. Note: - (a) Demolition to roof treatment should be done carefully . (b) Any damage occurred in the roof surfaces during demolition shall be made good by the contractor without extra cost to the department.
Mterial and Labour for providing plain cement concrete (1:2:4), type B1 using 20mm graded aggregate as in roof padding over RCC slab,laid in slope as per requirement, mixed with integral water proofing liquid admixture as per manufacture's instructions complete all as specified and as directed. Note :- (i) Average thichness of PCC shall be 50 mm (ii) Intrgral water proofing liquid admixture shall be measured and paid seperately.
Material and Labour for water proofing treatment with APP based standared membrane over PCC padding of roof with the following courses of treatment :- (a) Apply bituminous primer (IS-3384)@0.40kg/Ltr per sqm of the surface area,as per including cleaning the surfaces and all as specified.(Make of primer:-Pibial primer of TEXA or equivalent product of BITUMAT/BITUNIL/SIKA) (b) Apply APP plastomeric bitumen based water proofing membrane polyester reinforced (4 KG /Sqm)with 10 cm over laps and torch bonded at joints including surfacepreparation before and after application of treatment as per manufactures instruction complete all as specified and as directed.(Make of APP Membrane to Moply FP 4 kg mineral of TEXA/WP Shield 103 PM of SIKA or Eqiui valent material of BITUNIL/ BITUMAT.)
Taking down carefully copper/ aluminium point wiring (light, fan, call bell, socket or power) complete, including fittings and fixtures such as switches, ceiling rose, pendants, holders, regulators, sockets, light fitting etc. & removing from site and making good the disturbed surfaces of wall, ceiling etc. complete all as specified and directed
M & L for concealed point wiring complete with 1.5 sq mm FRLS,PVC insulated multi standard copper conductor single core cable 1100 volts grade,drawn into non metalic PVC rigid conduit medium grade of size not less than 20mm bore and conduit accessories fixed on wall roof etc, and including provn of PVC insulated 1.5 sq mm copper conductor cable for each continuity and connected to common earth dolly and pressed steel terminal boxes made out of 1.6 mm thick MS sheet concealed in wall and laminated sheet cover of 3 mm thick on top for housing the switches socket,outlet etc.,all as specified and directed by Engineer-in-Charge :- Note :- PVC conduit cutting chases of wall making good disturbed wall surfaces including finishing with cement mortor 1:4 matching with existing shade of the painted surface are deemed to be included in the quoted rate.
(a) One light point controled by one one way 5 Amp switch
(b) One fan point controlled by one , one way 5 Amp switch
(c) One 5 pin socket outlet 05 Amp on independent board .
(d) One 5 pin socket outlet 05 Amp on same board .
All as per item No 97 here-in-before,for one 15 Amps socket outlet but using 2.5 sq mm FRLS,copper conductor with 1.5 sq mm,PVC insulated single core cable for earth continuity conductor.
M & L concealed sub main wiring complete with 2 runs of 6 sq mm FRLS,single core,PVC insulated,unsheathed cable,1100 volts grade,multi standard with copper conductor drawn through and including PVC conduit pipe and accessories on surface wall/floors/concealed etc. with one run of PVC insulated 6 sq mm copper conductor for earth continuity conductor including taking down old US wiring all as specified and directed Note :- Two runs of cable one run of conduit and one run of copper earth wire shall be measured as one unit length.
Supply & fix switch piano flush button, single pole, one way 5 Amp
Supply & fix socket outlet, 2 in 1,5 pin 5 Amp flush type
Supply & fix switch socket combination 2 in 1, 2 and 3 pin 5 Amp flush type
Supply & fix switch socket combination, 5 in 1, multipurpose 5/15 Amps flush type universal ..
Supply & fixing ceiling fan regulator,electronic type,step type 5 speed A/C, 230 volts on the existing laminated sheet complete all as specified and directed.
Supply & fix ceiling rose, 3 terminals, surface bakelite / PVC / Polycarbonate, isolated body to be fixed on wall/ceiling complete all as specified and directed.
Supply & fixing PVC poly carbonate round blocks 10 cm dia complete all as specified and directed.
Supplying & fixing LED tube light fitting, 1 x 18 watt bipin holders, connector block etc. complete with all accessories internally pre-wired with and including 18 watt tube rod retrofit and connecting the same to ceiling rose with using copper conductor 23/0.0076 flexible twisted twin core cable ,and fixing the light fitting to walls / roof complete all as specified & directed
S&F lamp Holder insulated body with back plate angle/straight type suitable for batten complete all as specified and directed.
S&F single pole and neutral DB wall mounting type,240 Volts,12 Way with 200 Amps rated bus bar,double door suitable for fixing MCB's including connecting etc and taking down U/S DB ,main switch all as specified and directed.
S & F MCB SPN 6 Amps to 32 Amps 240 volts all as specified and directed.
S & F MCB SP 6 to 32 Amps 240 volts all as specified and directed.
S & F LED building security light fitting 60W new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having seperate driver compartment with IP65 protection and impact resistance of IK07 including mounting bracket of suitable size complete.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to stores complete all as specified as directed .
M&L painting of ceiling fans complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified as directed.
Hanging only ceiling fans (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified as directed.
Supply and fix exhaust fan steel body AC single phase complete with louvers shutter, voltage 230V, 50 Hz, Copper winding of sweep 300mm and connection complete all as specified as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE with brushless direct current motor (BLDC) complete all as specified as directed.
supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 kw capacity 25 litres, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connecting piece etc complete all as specified as directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) 7.50m long by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in (1 : 2 : 4) type B1 with 3 Nos 8 mm dia TMT bars both ways complete all as specified & directed by Engineer-in-Charge.
M&L cutting chases, pinning in making good to facing where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cils, sunshades sheleves, lintels, etc and cutting chases for concealed water tubing or concealed conduict wiring etc and making good cutting not exc 10 cm grith.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out complete all as specified and directed by Engineer-in-Charge.
Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer compete all as specified and directed by Engineer-in-Charge.
Removal of surplus spoil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 10 cm thick (punned down level) after laying of cable in trenches complete all as specified.
Material and labour for brick protection using old size sub class ‘B’ new bricks, laid flat dry but jointed, laid length wise perpendicular to the axis of cable all as specified and directed.
Taking down old unserviceable any size of LT cable and Supply and laying, jointing, testing and commisioning LT XLPE/PVC cables, PVC insulated, PVC Sheathed armoured LT 1100 volt grades 35 Sqmm 3.5 core heavy duty with aluminium stranded conductor through pipes, induct, on poles, in trenches etc.
Supply and laying 40 mm bore GI tubing light grade laid in trenches for cable protection complete all as specified as directed.
Supply and fix in replacement vertical TPN DB with MCCB incomer of 4 way in double door suitable for four pole MCCB (63A/100 A)as incomer including MCCB+12 modules incoming and outgoing make good of damaged surface/wall including re-connection with existing earth wire to DB all as specified and as directed.Note:- MCCB shall be measured and paid seperatly.
S & F MCB SP 6 to 32 Amps 240 Volts
Supply and fix in replacement MCCB triple pole & neutral 40-100 amps,,16 KA, with all incoming / outgoing connections suitable for fix 4 way vertical type TPN DB in double door twith proper size of aluminium lugs complete all as specified as directed .
Excavation in trrenches in hard/dense soil not exceeding 1.5 mtr wide and not exc 1.5 m depth for laying of GI pipes and getting out all as specified and directed.
Cutting existing steel tubing for alterations or additions (Each cut measured) of 40 mm bore all as specified and directed.
Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) of 20 mm bore all as specified and directed.
S&F GI water tubing, medium grade, 40 mm dia, incl fittings/accessories like sockets, bend, elbow, union etc laying in trenches all as specified and directed.
S&F GI water tubing, medium grade, 25 mm dia, incl fittings/accessories like sockets, bend, elbow, union etc laying in trenches all as specified and directed.
M&L for gunmetal globe/gate valve with iron wheel head, screwed both ends of sizes 25 mm ISI marked all as specified and directed.
M&L for gunmetal globe/gate valve with iron wheel head, screwed both ends of sizes 40 mm ISI marked all as specified and directed.
The Planters Engineering Corporation
ELECTRO COMMERCIAL CO
DEORA ELECTRIC WORKS
SHRI MILAN CHANDRA DAS
RBS Builders
ROY CONSTRUCTION
J B NATH AND SON
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .