Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹31.7 LAccepted-AOC AT BAGHUABOL CHHAK PO HATATOTA TALCHER ANGUL ODISHA PIN 759100 | ANUGUL | ODISHA | 759100 | L-1 | Accepted-AOC ACCEPTED AND AWARDED BY COMPETENT AUTHORITY | |
| 2 | L-2₹35.2 L+₹3.5 L (11.1%)Rejected-Finance AK PO GHANTAPADA TALCHER ANGUL ODISHA | TALCHER | ANGUL | ODISHA | L-2 | Rejected-Finance SINCE THE BIDDER IS NOT L-1 | |
| 3 | L-3₹35.6 L+₹3.9 L (12.4%)Rejected-Finance AT ITI CHHAK PO TALCHER DIST ANGUL PIN 759100 | ANUGUL | ODISHA | 759100 | L-3 | Rejected-Finance SINCE THE BIDDER IS NOT L-1 | |
| 4 | L-4₹35.8 L+₹4.1 L (12.9%)Rejected-Finance AT PANCHAMAHAL PO KARADAGADIA ANGUL ODISHA 759132 | ANUGUL | ODISHA | 759132 | L-4 | Rejected-Finance SINCE THE BIDDER IS NOT L-1 |
Tender Value
₹32.7 L
EMD Value
₹40,900
Closing Date
14 Feb 2023, 5:00 pmClosed
SO EnM LINGARAJ AREA
OFFICE OF THE GENERAL MANAGER, LINGARAJ AREA, AT/PO- DEULBERA COLLIERY, DIST- ANGUL, ODISHA, 759102
Execution of different electrical works in Silo Plant, Lingaraj OCP as per the direction of Engineer In-charge
2023_MCL_269954_1
GM/LA/SO/EnM/e-Ten/22-23/48 DT-03.02.23
Open Tender
Miscellaneous Works
Item Rate
120 days
LINGARAJ AREA
AS PER NIT
4 documents required · 4 mandatory
₹40,900
6 Apr 2023
3 Feb 2023
16 Feb 2023
4 Feb 2023
14 Feb 2023
4 Feb 2023
4 Feb 2023 - 7 Feb 2023
Amount
Supply and fixing of Pull Chord Switch (5A, 2NO+2NC, with LED Indicator (24V, DC) and Trip locking) with accessories as required.
Supply and Laying of Pull Chord Cable (5Core, 2.5Sq. mm, Copper, armoured PVC cable)
Supply and Laying of Pull cord wire: 6 X 7 galvanized wire construction, diameter 3 mm (1/8") covered with PVC coating 2-3 mm, total diameter approx. 5-6 mm
Supply and fixing of GI I Hook/ I bolt made of 8 SWG GI wire/ GI clip for carrying the Pull Chord Rope
Supply and Fixing of Belt Sway Switch (2NO + 2NC, Self Reset, 10Amps, 240V) with accessories as required.
Supply and fixing of Zero speed switch (controller with sensor) 240V AC speed setting range rpm 10-100, 5A amp with accessories as required.
Calibration & Testing of Over Current & Earth fault protective relay fitted in 33KV , 3.3 KV control panels.
Calibration & Testing of Earth Leakage, Master trip relay & Over voltage relay fitted in 33 KV , 3.3 KV Control panels
Primary Injection & Testing of 33KV/110V outdoor, & 3.3 KV/110V indoor Current/potential Transformers.
Providing, fixing ,commissioning & testing of automatic light control switch/Timer 220v AC Digital with all Timers, Breakers etc as required.
Erection of steel tubular or rail pole strut in cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc. as required. (volume of pole/ pipe not to be deducted) 0.8 mtr X 0.8Mtr X 1.2 Mtr X 18 Nos
Supplying and erection of galvanised stay set for 11 kV over head lines complete with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 em X 45 em X 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm X 600 mm), 7/4.00 mm dia G.l. stay wire and 11 kV strain insulator etc. in cement concrete 1 :3:6 (1 cement : 3coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required .
Erection of double pole 3 wire cross arm for 11KV/22KV/33 kV over head lines as required.
Supplying and erection of a set of cross bracing frame work for 11 kV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc. (as per drawing) and painting with primer and finish paint as required.
Supplying and erection of 11 kV pin insulator complete with large steel head G. I. pin, nuts, washers etc. as required.
Supplying and erection of 11 kV disc insulator for 11 kV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required. (0.394 Kg/Mtr X 18 span X 60 Mtr= 1080 Mtr)
Erection of cradle guard as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.l. wire, cross arms, insulators etc. as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 3.3 kV overhead lines with rated voltage 3 kV (rms) with a nominal discharge current rating of 5 kA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required
Erection of disc/ pin insulator for 11 KV over head lines as required
Supply and fixing of Earth leakege Relay 10mA to 1mA with CBCT 200mm dia in the existing Control panels of all four sub-stations of SILO Plant.
Providing and fixing of push button with required acessories for checking the healthiness of Earth Leakage Relays.
Providing and fixing of efficient Limit switches 110V AC, 10A with adjustable arm and roller, 1NO +1NC as a replacement of mercury switches installed in GOAB Switches.
Supply and installtion of NGR monitoring relay in existing NGR circuit in Main sub-station.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Faradays cage in main substation.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cuttinB, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Faradays cage in main substation.
Supply and erection of 7X2.5 Sq.mm Steel wire in the existing structure.
Supply and laying of GI Strip 65 X 10mm and isolating the same from mettalic support structures of switchyard. 30Mtr
Supply and fixing of Lock out and Tag out system in all three sub-stations of SILO Plant.
Supply and fixing of High voltage insulating mats confirming to IS 15652, Class A insulation with minimum thickness of 2mm on both back and front sides of all sub-stations of SILO Plant.
Supply and fixing of L&T HF TYPE HRC FUSE -16 A
Supply and fixing of C&S NH TYPE ,CDFL-1,SIZE-1 ,FUSE 250A
Supply and fixing of C&S HBC FUSE -10A
Total impact of GST for the purpose of CTC
SANJAY KUMAR SINGH
M/s Santoshi Maa Industries
M/S. PHASE AND CONTROL
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_279297.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .