| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAdmitted-Finance | ₹31.6 L | L1 | Admitted-Finance |
| 2 | L2₹33.4 L+₹1.8 L (5.66%)Admitted-Finance | ₹33.4 L+₹1.8 L (5.66%) | L2 | Admitted-Finance |
| 3 | L3₹56.5 L+₹25.0 L (79.1%)Admitted-Finance | ₹56.5 L+₹25.0 L (79.1%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
| Sl No | Description | Qty | Unit | CRS AND COMPANY L3 | MANJUNATHA ENTERPRISES L1 | HARISH M CONTRACTOR L2 |
|---|---|---|---|---|---|---|
| 1.00Finishing walls with Premium Acrylic Smooth exterior paint with silicone additives required shade: | ||||||
| 1.10 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm) sqm | 461.38 | Sqm | 69,207 ₹81,664 Lowest | 69,207 ₹81,664 Lowest | 87,200.82 ₹1,02,896.82 |
| 2.00Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. - External work | ||||||
| 2.10 | 50 mm nominal dia Pipes | 268.1 | Metre | 1,74,265 ₹2,05,633 Lowest | 1,74,265 ₹2,05,633 Lowest | 2,19,573.9 ₹2,59,096.9 |
| 2.20 | 25 mm nominal dia Pipes | 272 | Metre | 1,08,800 ₹1,28,384 | 1,22,400 ₹1,44,432 | 1,00,368 ₹1,18,434 Lowest |
| 3.00Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) for any diameter of pipe: | ||||||
| 3.10 | 150 mm dia nominal bore | 5 | each | 50,000 ₹59,000 | 32,500 ₹38,350 Lowest | 40,995 ₹48,374 |
| 4.00Water proofing work Lilly Pond Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage | ||||||
| 4.10 | For vertical surface two coats @ 0.70 kg per sqm per coat | 320 | Sqm | 2,40,000 ₹2,83,200 | 2,59,200 ₹3,05,856 | 1,35,360 ₹1,59,725 Lowest |
| 4.20 | For horizontal surface one coat @1.10 kg per sqm | 260 | Sqm | 1,95,000 ₹2,30,100 | 2,10,600 ₹2,48,508 | 95,940 ₹1,13,209 Lowest |
Tender Value
₹35.2 L
EMD Value
₹70,460
Closing Date
15 Aug 2026, 9:00 amClosed
Administritative officer
IIA, KORAMANGALA, Bengaluru
External Development and Infrastructure Works for the COSMOS Planetarium of the Indian Institute of Astrophysics, Mysuru, Karnataka
2026_IIAP_920527_1
101/PT/CIVIL/ EXTERNAL DEVELOPMENT INFRASTRUCTURE WORKS /IIA/COSMOS/2026 27
Open Tender
Civil Works
Item Rate
30 days
COSMOS Planetarium Mysuru
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹70,460
COSMOS Planetarium Mysuru
19 Aug 2026
4 Aug 2026
17 Aug 2026
5 Aug 2026
15 Aug 2026
8 Aug 2026
7 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Finishing walls with Premium Acrylic Smooth exterior paint with silicone additives required shade: | |||||
| 1.1 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm) sqm | 461.38 | Sqm | - | - |
| 2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. - External work | |||||
| 2.1 | 50 mm nominal dia Pipes | 268.1 | Metre | - | - |
| 2.2 | 25 mm nominal dia Pipes | 272 | Metre | - | - |
| 3Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) for any diameter of pipe: | |||||
| 3.1 | 150 mm dia nominal bore | 5 | each | - | - |
| 4Water proofing work Lilly Pond Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage | |||||
| 4.1 | For vertical surface two coats @ 0.70 kg per sqm per coat | 320 | Sqm | - | - |
| 4.2 | For horizontal surface one coat @1.10 kg per sqm | 260 | Sqm | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
Tendernotice_2.pdf
PDF • 0.50 MB
BOQ_967347.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .