Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC BMC 1 54 GANTI NETAJI PALLY PO GANGANAGAR KOLKATA 700 132 INDIA | 24 PARAGANAS NORTH | WEST BENGAL | 700132 | L1 | Accepted-AOC Quoted Lowest Rates | |
| 2 | L2₹9.8 L+₹1.0 L (11.9%)Rejected-Finance | L2 | Rejected-Finance Quoted Higher Rates | |
| 3 | L3₹10.4 L+₹1.6 L (18.2%)Rejected-Finance | L3 | Rejected-Finance Quoted Higher Rates | |
| 4 | L4₹11.3 L+₹2.6 L (29.4%)Rejected-Finance | L4 | Rejected-Finance Quoted Higher Rates | |
| 5 | L5₹11.9 L+₹3.1 L (35.4%)Rejected-Finance 6A BANAMALI GHOSHAL LANE KOLKATA 700034 | KOLKATA | WEST BENGAL | 700034 | L5 | Rejected-Finance Quoted Higher Rates |
Tender Value
Refer Docs
EMD Value
₹19,400
Closing Date
18 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ SWAPNESH KOLI GE I CG P KOLKATA
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
PROVISION OF STORAGE ACCOMMODATION AND GAZEBO AT OPEN GARDEN AT CGRA MANICKTALA UNDER GE (I) (CGP) KOLKATA
2020_MES_407623_1
8895/E8
Open Tender
Civil Works
Item Rate
180 days
KOLKATA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE I CG P KOLKATA
₹19,400
Yes
5 Feb 2021
28 Dec 2020
20 Jan 2021
28 Dec 2020
18 Jan 2021
11 Jan 2021
60 days
Amount
Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil complete all as specified and as directed.
Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and exc. 1.5 m. but n. exc. 3.0 m. in depth and getting out in soft/loose soil complete all as specified and as directed.
M&L treating the back fill in contact with foundation at the rate of 7.5 Ltrs of emulsion per Sqm of vertical surface (Area of the substructure in contract with back fill to be measured) complete all as specified and directed.
M&L treating top surface of filled earth at the rate of 5 Ltrs of emulsion per Sqm of surface all as specified and directed.
M&L treating the soil alongwith external perimeter of building at the rate of 2.25 Ltr of emulsion per mtr of the perimeter wall as specified and directed.
M&L PCC 1:4:8 type D2 type (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
M&L RCC (design mix) M-25 (using 20 mm graded crushed stone aggregate) as in foundation, plinth beams, base of column, footing and mass concrete etc. complete all as specified and directed.
M&L RCC (design mix) M-25 (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers posts and struts etc. complete all as specified and directed.
M&L RCC (design mix) M–25 (using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintel over 1.5 m span complete all as specified and directed.
M&L RCC (design mix) M-25 (using 20 mm graded crushed stone aggregate) as in slab, supported on walls, beams, columns in floors, roofs, landing, shelves etc. complete all as specified and directed.
M & L RCC M-25 (Design Mix) (20mm graded agg) as in chajias, complete all as specified and as directed.
Use and waste form work to side of concrete foundation, footings, bases of columns, raft and beams and similar work, vertical or to batter as in rough finished surfaces of concrete all as specified and directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns etc. square, rectangular or polygonal section as in fair finished surfaces complete all as specified and directed.
Use and waste of form work to sides and soffits of floor or roof beams, lintels, over 1.5 m span, cantilevers, shelves including supports, overhangs etc. complete all as specified and directed as in flat and fair finished surfaces complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs , floor slabs landing and similar work , not exceeding 200 mm thick (Horizonal or sloping) for flat fair finished surfaces of concrete complete all as specified and directed
M&L MS TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia as reinforcement complete all as specified and directed.
M&L M.S. TMT bars 5 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia as in stirrups spaces, binders and nibs etc. complete all as specified and directed.
S&F 6 to 8 mm dia TMT Bars incl cutting bending, binding with MS annealed wire not less than 0.90 mm dia for slab,complete all as specified and as directed.
M&L brick work with sub class 'B' bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricks complete all as specified and as directed.
Surface dressing not exc. 15cm deep in soft/loose soil all as specified and directed.
M&L for sand filling under floor including watering and consolidation complete all as specified and directed.
M&L PCC 100 mm thick 1:4:8 type D2 type (using 40 mm graded broken stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:4 including WPC @ 2% by weight of cement or as per manufacturer instructions for final coat, finished surface even and smooth without using extra cement complete all as directed .
Supply only liquid water proofing compound conforming to IS-2465-1975 complete.
M&L for 15 mm thick rendering on brick or concrete surfaces of wall in CM 1:6 and finished even and smooth without using extra cement complete all as directed.
M&L rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M & L preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
M&L preparation of newly plastered surfaces of wall and apply three coats of white wash complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white washing complete all as specified and directed.
M & L 150 mm thick PCC(1:3:6) Type C-2 using 40 mm graded stone aggregate as in sub floor complete all as specified and as directed.
M&L screed bed or bedding layer 20 mm thick in cement mortar 1:4 on floors for laying floor finish complete all as specified and as directed.
M&L backing Layer 10mm thick in Cement Mortar 1:4 on Walls, etc. for fixing Tiles as Skirtings, Dados, etc, complete all as specified and directed.
M & L for Kota stone slab 18-20 mm thick in floor laid over cement screed and jointed with with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.(Note : Screed bed or bedding layer shall be measured and paid separately under respective items in this schedule).
M & L for Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.(Note : Screed bed or bedding layer shall be measured and paid separately under respective items in this schedule).
M&L Marble (table rubbed and polished) tiles, 18 - 20 mm thick machine cut in steps, jambs, pillars, window cills, cooking platforms and like laid over cement screed bed 15 mm thick of 1:6 CM and jointed with grey cement slurry and pointed with white cement (1:2) with admixture of pigment to match the shade of the marble of folllowing types (a) Markhana white including cutting and polishing complete all as specified and directed.
M&L Granite (of any type) tiles, 18 - 20 mm thick machine cut in steps, jambs, pillars, window cills, cooking platforms and like laid over cement screed bed 15 mm thick of 1:6 CM and jointed with grey cement slurry and pointed with white cement (1:2) with admixture of pigment to match the shade of the granite stone including cutting and polishing complete all as specified and directed.
S&F M.S. framed work such as grills gratings etc with end of bars shouldered/or riveted or forged into spikes framed guard bar, barred iron doors, ladders, framed balusters, walkways, railing, frame work of water tanks and similar works steel quality conforming to Fe-290, Grade E- 165 complete all as specified directed .
S&F rolled mild steel section Fe 410 -W (Gde- E- 250) quality "B" framed work as in doors or gates with frame/chowkat with hand made holdfast made from angle of other section with gusset plates, rails braces, etc. complete drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings with sliding door bolts etc. (excluding steel covering which shall be measured and paid separately under respective items in this Schedule) and hanging fastening and fixing complete all as specified and directed
S&F MS plain black sheet 1.00 mm thick in wall cladding ,steel gates, railing and similar works cut to size ,edges beaded if directed, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel members etc. with plain 40 mm lap joints oe welded / rivetted seems including bending, turning up, mitred angles, stopped ends, outlets etc. as required complete all as specified and directed .
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed.
M&L 150 mm thick plain cement concrete 1:2:4 type B2 (using 40 mm graded crushed stone aggregate) as in floor and finishing the top surface even and smooth without using extra cement all as specified and directed.
Excavating in post holes (or similar holes) each n. exc. 0.5 cum, getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25 cm watering and removing surplus soil to distance n. exc 50 m and making good surface complete all as specified and directed.
M&L cement concrete 1:2:4 Type B2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
M&L reinforced cement concrete 1:2:4 Type B1 (using 20 mm graded crushed stone aggregate) as in beams, slans supported on wall, columns in roofs etc. complete all as specified and directed.
M & L for half brick work with sub class "B" bricks built in cement morter 1:4 straight or curved on plain exc 6 mtr mean radius complete all as specified and as directed.
M&L MS in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tube conforming to IS 1161 -1979 grade St -240 complete all as specified and directed.
M&L M.S. Rolled sections as in framing for cladding, glazing and the like fixed with cleats and connecting complete grade of steel Fe-410-W (Gde - E-250), quality - A complete all as specified and directed.
M&L for roof tile, mangalore pattern, interlocking at side joints ,laid over roof complete all as specified and directed.
M&L for ridges or hip tiles to suit mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or CM 1:6 complete all as specified and directed.
S&F 2nd class hardwood weather boarding, clean sawn, thickness 20-25 mm and rebated on thick edge to give 20mm laps and fixed complete all as specified and directed.
M&L preparation of new or previously untreated wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L Vitrified Ceramic tiles dark shade 10mm thick (Square or Rectangular) polished area of each tiles not exceeding 0.36 Sqm, in floors, set and Jointed in neat cement slurry and pointed in coloured cement to match the tiles, complete all as specified and as directed. (Note : Screed bed or bedding layer shall be measured and paid separately under respective items in this schedule)
M&L Vitrified Ceramic tiles dark shade 10mm thick (Square or Rectangular) polished area of each tiles not exceeding 0.36 Sqm, in vertcal surfaces, set and Jointed in neat cement slurry and pointed in coloured cement to match the tiles, complete all as specified and as directed. (Note : Screed bed or bedding layer shall be measured and paid separately under respective items in this schedule)
M&L rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
M&L point wiring with 1.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed HRFR / FRLS copper conductor cable 1100 Volts grade drawn through with and including PVC conduit medium duty (ISI marked) not less than 20 mm dia and all fittings and accessories (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core HRFR / FRLS copper cable as earth continuity wire connecting to common earth point including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC / Plastic laminated sheet. top cover, suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc complete for flame proof light / exhaust fan point controlled by one way switches complete all as specified and directed.
S&F 20W LED flame proof tube light fitting cast aluminium housing and ring and heat resistant glass, high tensile steel external cover along with all fixing arrangement complete all as specified and directed (Make : Crompton cat no EXTN2LT8-16/20 or quivalent in Havells/ Philips/ Bajaj).
S&F LED T8 tube with extruded Al body, PC diffuser and in built driver complete all as specified and directed (Make : Crompton cat no LTT8-20 or quivalent in Havells/ Philips/ Bajaj).
S & F LED Batten light 4ft 20 watt with extruded al housing,3" X3" PVC block 2 Nos ,Lamps,driver,with efficacy 125 lum/watt IP- 65 connector etc incl hanging arrangement with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting through suitable size flexible PVC pipe making good to wall for old fitting ciomplete all as specified and directed . Make: CG / Bajaj/Philips/Havells)
S&F LED bulk head fitting 1x10 watt for exterior application / building security complete all as specified and directed (Make : Crompton cat no LBHP-10-CDL or quivalent in Havells/ Philips/ Bajaj).
S&F Flame proof exhaust fan AC single phase 230/240 V of size 450 mm/ 18 inch with louver and all necessary fittings complete all as specified and directed (Make : Sudhir/kainga/Baliga).
S&F Flame proof switch rotary type including all necessary fittings complete all as specified and directed (Make : Sudhir/kainga/Baliga).
S & F switch piano, flush type, 5/6 Amps, 240 Volts, single pole, one way, conforming to IS complete all as specified and as directed.
M & L Ceiling rose, surface type polycarbonate/ PVC three terminals, conforming to IS, complete all as specified and as directed.
Supply and fix sheet metal enclosure powder coated, MCB DB SPN 2 way double door for incoming bus bar, neutral links all as specified and directed . (Make :Legrand / Schneider /GE)
Supply and fix MCB SPN 240V, 6-32 Amps capacity complete all as specified and directed. (Make : Legrand cat No 4086 17 or equivalent in Schneider/GE )
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 6Sqmm 2 core complete all as specified and as directed.
S&F 40 mm dia steel water tube light grade galvanised with all fittings and fixed complete laid in trenches complete all as specified and directed.
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron or steel earth lead MS flat 25 x 4 mm by means of nuts, bolts, check nuts and washers of galvanised iron or steel, earth wire protected by galvanised iron pipe 40 mm dia (light grade) and connected to main switch board or main control panel as directed and as specified including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 5 cm thick of size as shown reinforced with 8 mm dia TMT / deformed bars 100 mm c/c both ways including one handle made of 12 mm dia MS bars of length 500 mm, funnel, wiremesh 20 mm bore galvanised iron pipe medium grade for watering, charcoal and salt in alternate layers including necessary earth work complete all as shown in elect plate No. 3 of SSR Part I, complete all as specified & directed.
M&L for GI strip 25 mm x 4mm as earth continuity conductor fixed to wall/burried in ground/drawn through conduit or pipe or fixed to pole for loop earthing complete all as specified and directed.
M&L for sand cushioning for protection of cables (below, above and around the cable laid in trenches) complete using clean, dry sand complete all as specified and as directed.
Supply and laying well burnt bricks sub class 'B' laid breadth wise along length of cable in trenches after sand cushioning laid for underground cable protection complete all as specified and as directed.
All as per item no.57 above but for one three pin 5 Amp socket outlet on independent board.
M&L point wiring with 2.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed HRFR / FRLS copper conductor cable 1100 Volts grade drawn through with and including PVC conduit medium duty (ISI marked) not less than 20 mm dia and all fittings and accessories (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 2.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core HRFR / FRLS copper cable as earth continuity wire connecting to common earth point including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC / Plastic laminated sheet. top cover, suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc complete for three pin 15 Amp socket outlet on independent board complete all as specified and directed.
S&F Modular metal flush box, 3 module complete all as specified and as directed. (Make-Legrand / CRABTREE, L&T (ORIS), CONTROL & SWITCHGEAR, SIEMENS, ABB, Havells)
S&F Modular metal flush box, 6 module complete all as specified and as directed. (Make-Legrand / CRABTREE, L&T (ORIS), CONTROL & SWITCHGEAR, SIEMENS, ABB, Havells)
S&F white cover plate with frame for Modular switch, 3 module complete all as specified and as directed. (Make-Legrand /CRABTREE, L&T (ORIS), CONTROL & SWITCHGEAR, SIEMENS, ABB, Havells)
S&F white cover plate with frame for Modular switch, 6 module complete all as specified and as directed. (Make-Legrand /CRABTREE, L&T (ORIS), CONTROL & SWITCHGEAR, SIEMENS, ABB, Havells)
S & F Switch socket combination 5 Pin, 6 Amps, 240 Volts, modular type multi-purpose, conforming to IS complete all as specified and as directed. (Make-Legrand / CRABTREE, L&T (ORIS), CONTROL & SWITCHGEAR, SIEMENS, ABB, Havells)
S & F Switch socket combination 5 Pin, 6/16 Amps, 240 Volts, modular type multi-purpose, conforming to IS complete all as specified and as directed. (Make-Legrand /CRABTREE, L&T (ORIS), CONTROL & SWITCHGEAR, SIEMENS, ABB, Havells)
S&F 25W LED round polycarbonate down lighter with driver along with all fixing arrangement complete all as specified and directed (Make : Crompton / Havells/ Philips/ Bajaj).
S&F 10W LED Bollard IP 65 rated pyramid tripod type, soft 360 degree and all fittings complete all as specified and directed (Make : Crompton / Havells/ Philips/ Bajaj).
S&F wall mounted Fan hi speed 400mm sweep including all fixing arrangement complete all as directed.(Make-USHA/BAJAJ/Havells)
S&F white blanking plate one module complete all as specified and directed.(Make-Legrand / CRABTREE, L&T (ORIS), CONTROL & SWITCHGEAR, SIEMENS, ABB, Havells)
S & F modular switch 6 Amps, 240 Volts, single pole, one way, single module conforming to IS complete all as specified and as directed.(Make-Legrand/CRABTREE, L&T (ORIS), CONTROL & SWITCHGEAR, SIEMENS, ABB, Havells)
Supply and fix sheet steel enclosure SPN DBs, 8 way, double door for MCBs with 200 Amps rated bus bar complete all as specified and directed. ( Make Legrand /Schneider /GE)
Supply and fix MCB TPN 415V, 6-32 Amps capacity complete all as specified and directed. Make : Legrand / Schneider/GE
Supply and fix MCB SP 240V, 6-32 Amps capacity complete all as specified and directed. (Make : Legrand / Schneider/GE )
M&L Sub main wiring with two runs of 4.0 sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through and including rigid PVC non mettalic surface conduit medium duty with conduit accesseries such as junction boxes, bends, tees etc. complete including one run of 2.5 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed including taking down old one. (Note :-(i) One run of PVC conduit, Two runs of 4.0 sqmm single core cable, one run of 2.5 sqmm earth continuity wire to be measured as one length). (ii) Chase cutting for replacement of defective/ unserviceable concealing conduit by new conduit if ordered, shall be measured & Paid separately under respective item in this schedule.).
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 10 Sqmm 2 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 16 Sqmm 4 core complete all as specified and as directed.
M & L earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with the top edge of earth plate at depth not less than 1.5m below ground level connected with 4mm dia GI wire by means of bolts washers and protected by 15mm bore, medium grade GI pipe, funnel with 20mm bore GI medium grade watering pipe, wire mesh, copper lugs including concrete pit in PCC 1:3:6 type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350X350X50 mm, reinforced with 8mm dia deformed bars @15 cm C/C both direction and 10mm MS handle of suitable size, charcoal or coke and salt in alternate layers, necessary earth work in soft/loose soil, all as shown in Electrical Plate No 3 of MES Schedule Part-I and testing, complete all as specified and as directed.
SOVA ENTERPRISE
M/S SK PAUL
MAZUMDER & CO
AUTO ELECTRICALS
DIPAK ENTERPRISE
KWALITY CONSTRUCTION
BHASKAR SUPPLY AGENCY
BENGAL TRADERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .