| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹34.4 L+₹3.4 L (11.1%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹36.2 L+₹5.3 L (17.0%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹36.8 L+₹5.8 L (18.7%)Rejected-Finance PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹37.4 L+₹6.5 L (20.9%)Rejected-Finance AT PO CHANDIPUR BALASORE 756025 | BALASORE | BALASORE | ODISHA | 756025 | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
24 Aug 2023, 6:00 pmClosed
GARRISON ENGINEER
GE I R and D Chandipur Post Chandipur PIN 756025
REPAIR REPLACEMENT OF DISTRIBUTION BOX SUB MAIN WIRING LIGHT FITTINGS EARTHING REPAIR TO DOMESTIC SUMMER APPLIANCES WITH ALLIED WORK UNDER AGE BR BALASORE AND REPAIR REPLACEMENT OF CERTAIN SUB MAIN AND POINT WIRING MODULAR CONVENTIONAL SWITCH
2023_MES_610928_1
8856/CDP
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
chandipur and Balasore
As per tender documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandipur
₹60,000
Yes
12 Oct 2023
27 Jul 2023
26 Aug 2023
27 Jul 2023
24 Aug 2023
10 Aug 2023
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.
Taking down carefully copper /aluminium point wiring (light, fan socket or power) complete, including fixture and fittings such as switches, ceiling rose, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia concealed in wall/ceiling, etc. and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 2.5 Sqmm (phase & neutral) and one run of 2.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia concealed in wall/ceiling, etc. and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 5/6 amps socket outlet on independent board controlled with one, oneway switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia concealed in wall/ceiling, etc. and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for for one 5/6 amps socket outlet on same board controlled with other switch complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 2.5 Sqmm (phase & neutral) and one run of 2.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia concealed in wall/ceiling, etc. and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 15/16 amps socket outlet on independent board controlled with one, 15/16 amps one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 5/6 amps socket outlet on independent board controlled with one, oneway switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for for one 5/6 amps socket outlet on same board controlled with other switch complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 2.5 Sqmm (phase & neutral) and one run of 2.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 6/16 amps socket outlet on independent board controlled with one, 16 amps one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
All as per Sl Item No. 2 here-in-before but drawn in through existing concealed conduit.
All as per Sl Item No. 3 here-in-before but drawn in through existing concealed conduit.
All as per Sl Item No. 4 here-in-before but drawn in through existing concealed conduit.
All as per Sl Item No. 5 here-in-before but drawn in through existing concealed conduit.
M&L switch piano, flush type single pole, one way 5 Amps including connection.
Fixing only switch piano, flush type single pole, one way 5 Amps including connection (Serviceable switch obtained from respective item shall be reused.)
M&L switch socket combination 5 pin, 2 in 1, 5 Amp flush type including connection
M&L switch socket combination 5 Pin, 15 Amps and one 5 amps controlled by one switch.
M&L ceiling rose PVC poly carbonate, isolated body with three terminals including connection.
S & F Electronic fan regulator, stepped type 120/280V complete all as directed.
Taking down Sub main /Sub circuit wiring of any type and size including conduit / casing capping / batten wiring complete all as directed.
M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 2.5 Sqmm to be drawn in and including PVC concealed conduit 25 mm dia (medium grade). Note: Three runs of 2.5 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
All as per Sl Item No 21 above but in PVC casing caping (medium duty) of size not less than 20 mm width
M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 4 Sqmm to be drawn in and including PVC concealed conduit 25 mm dia (medium grade). Note: Three runs of 4 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
All as per Sl Item No 23 above but in PVC casing caping (medium duty) of size not less than 20 mm width
M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 6 Sqmm to be drawn in and including PVC concealed conduit 25 mm dia (medium grade). Note: Three runs of 6 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
All as per Sl Item No 25 above but in PVC casing caping (medium duty) of size not less than 20 mm width
M&L Submain wiring using six runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 6 Sqmm to be drawn in and including PVC conduit 25 mm dia (medium grade). Note: Six runs of 6 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
M&L Submain wiring using six runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 10 Sqmm to be drawn in and including PVC conduit 25 mm dia (medium grade). Note: Six runs of 10 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
Supply and fix in repair vertical TPN MCCB DB 8 way with 200 Amps rated busbar, double door type including provision for fixing MCCB 4 pole 100 Amps, 25 KA complete including taking down old DB and making disturbed surafce good to match the existing surface.
S&F MCB DB TPN 4 way having degree of protection as per IP 42 or above with metal door (double door) 415 Volts complete copper bus bar with neutral link with provision for MCB TPN as incomer and MCB SPN MCBs as outgoing with blanking plates etc fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified.all as directed.
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 12 way, 240 Volts fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified.
All as per in Sl Item No. 31 here-in-before but of SPN 8 way,240Volts double door as in repair.
All as per in Sl Item No. 31 here-in-before but of SPN 4 way,240Volts double door as in repair.
S & F in MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 100 Amps.
All as per in Sl Item No. 34 above but of capacity 63 Amps, 4 Pole, 16 KA.
S&F in repair MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 63 Amps.
S&F in repair MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 100 Amps.
S & F in repair MCB, SPN. 6 to 32 Amps rating 240, volt, 'C' series, 10 kA,
S & F in repair MCB, SPN. 40-63 Amps rating 240, volt, 'C' series, 10 kA,
Fixing only MCB SPN 32-63 Amps (Serviceable MCB obtained from respective item shall be reused).
S & F in repair , MCB, TPN, 415 V, 50Hz, 10kA, 'C' series, 40 to 100 Amps series.
S & F in repair , MCB, TP, 415 V, 50Hz, 10kA, 'C' series, 25 to 63 Amps series.
S & F in repair MCB, SP, 6 to 32 Amps, 240 volt, 'B' Series, 10 kA, as in repairs.
Fixing MCB SP 6-32 Amps (Serviceable MCB obtained from respective items shall be reused).
Supply and fix in repair LED retrofit tube complete with powder coated decorative LED T-8 Batten with polycarbonate tube of capacity 20 Watt complete with including PVC insulated flexible copper wire of size .5 sqmm 2 core from ceiling rose to fitting complete incl taking down old fitting all as specified and directed
All as per Sl item No. 45 here-in-before but retrofit LED tube rod only of capacity 20 Watt Make : C & S Cat part No LT4F20WLEDT8/WDI or equivalent model of make list as in Appendix 'A'.
All as per Sl item No. 45 here-in-before but 10 Watt, 2' all as specified and directed.
S&F High-quality design LED Tube light fittings in extruded aluminium housing with high quality PC diffuser 1x20 watt with enhances safety and relible ,robust housing structure with decorative end caps complete with all accessories including LED tubelight internally pre-wired with capacity of 125 lumen/watt and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed.
S&F High-quality design LED Tube light fittings in extruded aluminium housing with high quality Milky white diffuser 1x20 watt with enhances safety and relible ,robust housing structure with decorative end caps complete with all accessories including LED tubelight internally pre-wired with capacity of 100 lumen/watt and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed.
Supply & fix LED luminaire 600 mm x 600mm 35/36 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver holder & LED lamp suitable for roof ceiling including connection up with driver three core flexible copper conductor case of suitable size complete. all as specified and directed.
S & F in repair Sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP of 20 Amps .
M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron including 40mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate), 50mm thick precast RCC type B1, (1:2:4)(using 20 mm graded stone aggregate) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 25mm x 4mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No.3 of SSR Part-I, 2009 and all as directed including taking down old unserviceable one. (Note : GI strip upto 7.5 m length shall be deemed to include in the cost of above item.
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified.
S & F in repair Earthing conductor with GI strip of size (25 x 4) mm complete all as directed.
Material and labour in replacement for Galvanised iron strip 32 x 6 mm burried in ground complete all as specified and directed.
Disconnecting electrically and dismantling of ceiling fans of any make capacity and type, washing thoroughly of bearing /bush, fan blades and body of fan by kerosene /petrol etc and greasing for smooth functioning. Replacement of worn out/defective unserviceable parts (where ever necessary), reassembling the same including provision of three core flexible copper wire 1.5m long, including one coat of synthetic enamel paint (first quality) with super glossy finish to fan body and blades refixing the same to its original position including testing complete all as directed by Engineer-in-Charge. (NOTE : Replacement of worn out/ defective/unserviceable parts, flexible copper wire and rewinding shall be measured and paid separately under relevant items of these schedule).
All as per Sl Item No. 56 here-in-before but for Exhaust fans of any size and make.
All as per Sl Item No. 56 here-in-before but for air circulator fans/wall mounting fans of any size and make.
M&L Rewinding the motor of AC ceiling fan of any make and size (1200/1400mm) with super enamelled copper wire of adequate size/gauge including all insulation materials, varnishing etc complete all as directed.
All as per Sl Item No. 59 here-in-before but for exhaust fans of 300/380mm sweep of any make.
All as per Sl Item No. 59 here-in-before but for air circulators/wall mounting fans of any make and size.
Supply only Ball bearing of suitable size for any type/make of ceiling fan, Make : TATA/NBC/SKF.
All as per Sl Item No. 62 here-in-before but for Exhaust fans of any type/size/make.
All as per Sl Item No. 62 here-in-before but for air circulators/ wall mounting fans of any type/size/make.
Supply only capacitor 220 volts, 2.5 mfd suitable for ceiling fan, Make : SARADA/ TIBOCON/ UNIVERSAL.
Supply only capacitor 220 volts,4 mfd suitable for ceiling fan, Make : SARADA/ TIBOCON/ UNIVERSAL.
S & F in repair Hanging clamp (FI 25 mm x 300 mm length) for ceiling fan of adequate size including rubber reel, nuts, bolts and washers etc complete including taking down old unserviceable one, all as directed.
S&F in repair LED Bldg security light fitting 45 Watt with all accessories, (with extra driver) attractively styled high pressure die cast housing acting as a heat sink housing epoxy powder coated in dark graphite grey colour suitable for mounting bracket of 40mm bore GI pipe light grade complete with all accessories including taking down old fitting as directed. Make - C&S Cat Part No. LTESS18x2.5HPLED/LS or equivalent model of make list as in Appendix 'A'.
Taking down geyser and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete for 25 Ltr capacity complete all as specified and as directed.
Supply and fixing as in replacement for heating elements of 1.5 /2 KW 230 V suitable for water heater of any type including connection with suitable cable complete all as specified and as directed.
Supply and fixing as in replacement for thermostat switch of geyser 230 V, 30 degree to 90 degree centigrade temp range to be set at 70 degree to 50 degree centi grade suitable for water heater complete all as specified and as directed.
Supply and fixing as in replacement for 450mm long brass CP braided hoses with 2 nuts without nipple suitable for geysers complete all as specified and as directed.
Supply and fixing as in replacement for PVC inlet connector pipe 450mm long for geyser, heavy duty,with brass coupling both ends sutiable to fix inlet of geyser complete all as specified and as directed.
Supply and fixing as in replacement for apparatus plate , including suitable for water storage heater of 25 ltrs capacity complete all as specified and as directed.
Supply and replace rotary type compressure suitable for split type AC cap. 1.5/2.0 ton of make: technomush/kirloskar/ Voltas/Carrier/LG
Material & Labour for flushing, pressurising the system, leakage testing vacuumisation and gas charging at appropriate pressure all as directed.
Supply and replace starting capacitor suitable for window/split type AC cap 1.5/2.0 ton.
Supply and replace thermostate suitable for window/split type AC cap 1.5/2.0 ton of MAKE: indfass/denfoss.
Supply and replace overload relay suitable for window/ Split type AC cap 1.5/2.0 ton
Supply and replace blower fan motor suitable for window/ Split type AC cap 1.5/2.0 ton
Supply and replace micro filter suitable for window type/split type AC cap 1.5/2.0 ton
Supply and replace front PVC grill suitable for window type AC cap 1.5 ton as per existing sample.
Material & Labour for taking down AC split type complete inner and outer unit and relocate as per given site complete including refixing inner & outer unit piping with insulation and testing all as directed.
KRISHNA ENTERPRISES
Bansal And Co
RANA ENTERPRISES
DS ENTERPRISES
MS SUBHAM ENGINEERING AND CO
chauhan syndicate
Bidder Name
RANA ENTERPRISES
DS ENTERPRISES
Bansal And Co
KRISHNA ENTERPRISES
chauhan syndicate
ELECTRO COMMERCIAL CO
MS SUBHAM ENGINEERING AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .