Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹41.3 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹44.8 L+₹3.5 L (8.56%)Rejected-Finance | L-2 | Rejected-Finance Being other than L-1 | |
| 3 | L-3₹48.4 L+₹7.2 L (17.3%)Rejected-Finance | L-3 | Rejected-Finance Being other than L-1 |
Tender Value
₹46.6 L
EMD Value
₹93,240
Closing Date
21 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI A K DUBEY, IDSE, SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO BLDG NO P-25 (16 ORS MD ACCN) AT OLD MEDICAL COMPLEX UNDER GE (NORTH) UDHAMPUR
2021_MES_450806_2
CWE/U(N)-32/2021-22
Open Tender
Civil Works
Item Rate
270 days
UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹93,240
Yes
17 Sept 2021
2 Aug 2021
23 Aug 2021
2 Aug 2021
21 Aug 2021
9 Aug 2021
60 days
Amount
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engr-in-Charge.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete all as specified and as directed by Engr-in-Charge.
Taking down shutters of any descriptions area exceeding 1 square metre but not exceeding 2 square metre each and refixing in same opening complete all as specified..
Non skid, light coloured, white printed ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Glazed coloured ceramic tiles 450mm x 300mm x 7 to 8mm on vertical surfaces of walls as in dado/skirting etc., set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 10 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engr-in-Charge.
Non skid, light coloured of apporved pattern & design, white printed ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Providing cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, roof padding, kerbs not provided for including weathering, slightly rounded or chamfered angles including necessary formwork complete all as directed and specified.
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
Treatment of sunken floor surfaces with 0.488 kg/Sqm first layer of slurry of cement mixed with acrylic based polymer modified cementitious composite compound @0.253 Kg/Sqm. This layer shall be allowed to be cured for 4 hours and then applying in second layer slurry of cement @ 0.242 Kg /Sqm mixed with acrylic based polymer based modified cementitious composite compound @0.126 Kg/Sqm. This layer shall be allowed to be cured for 4 hours, including taking down old/existing treatment with wire brusing and clearing the dust and foreign material before new treatment and incuding one GI light grade 450mm long 32 mm dia Spout to each sunken floor, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:5:10 type E-2 using 40mm graded crushed stone aggregates as in sunken floor/ foundatiom, complete all as specified and as directed by Engr-in-Charge.
Vitreous china water closet, 'Orissa pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Vitreous China wash down water closet pan and seat cover (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including P or S trap and including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device,including jet sprey butterfly heavy PVC hose including connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc. including cast iron 'P' or 'S' trap for 100mm bore of pipe, fixed in repairs complete all as specified and as directed by Engr-in-Charge.
Cutting holes into or through brick walls/RCC beams exceeding half brich but not exceeding one brick, built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, complete all as specified and as directed by Engr-in-Charge.
Vitreous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 incl PVC waste pipe 32mm dia & CP grating with holes with pedestal of china ware including taking down and refixing, complete, all as specified and as directed by Engr-in-Charge. Note: damage to existing WHB will be furnised by contractor without any extra cost to Govt.
Brass chromium plated centre hole basin mixer 15 mm bore for mixing hot & cold water screw down for iron pipe, fixing in repair complete all as specified.
S&F stainless steel soap tray fixed with wooden gutties and screws to wall surfaces, complete all as specified.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed by Engr-in-Charge
PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified.
Dismantling of cast iron or reinforced concrete drain pipes, any size jointed in cement mortar and taking out of trenches or fixed to wall, if required complete all as specified and as directed by Engr-in-Charge.
110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with PVC clamp of suitable size fixed in repairs, complete all as specified and as directed by Engr-in- Charge.
75mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with PVC clamp of suitable size, complete all as specified and as directed by Engr-in- Charge.
110 mm bore PVC (SWR) bends any radius with acess door and fixed solvent etc complete all specified and as Directed (ISI Marked)
75 mm bore PVC (SWR) bends any radius with acess door and fixed with solvent etc complete all specified and as Directed (ISI Marked)
PVC SWR branch piece , single (singleT/ Y) equal or unequal 110 mm size fixed with joint sealent etc complete all specified and as Directed
PVC SWR branch piece , single (singleT/ Y) equal or unequal 75 mm size fixed with joint sealent etc complete all specified and as Directed
Red/black granite(of any type) stone slab 16 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing with rounding to edges of stone slabs one edg complete Including 20mm thick backing coat CM 1:3 complete all as specified and as directed by Engr-in-Charge.
Dismantling water tank of capacity exceeding 250 litres but not exceeding 500 litres each and removing from site/to store, complete all as specified and as directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank , ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 500 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 25 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
20mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
25mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc., 15 mm bore with new fittings, complete all as specified and as directed by Engr-in-Charge.
Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc., 20 mm bore with new fittings, complete all as specified and as directed by Engr-in-Charge.
Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc., 25 mm bore with new fittings, complete all as specified and as directed by Engr-in-Charge.
Bib taps, long body, fancy type cast copper alloy, chromium plated, screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair Chromium plated shower roses with arm 195 mm long with bend of 45 dgree with flange, with or without swivel joints, 125mm size, including fix into steel pipe or union of bore 15mm complete all as specified and as directed by Engr-in-Charge.
Angular stop cock/Angle cock with wall flange, fancy type, brass, chromium plated, screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, complete all as specified and as directed by Engr-in-Charge.
Stop valves, fancy type, chromium plated, cast copper alloy, with long shank and cup (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm , all as specified.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 25mm fixing in repair, complete all as specified.
Taking down cement plaster, dado/skirting of any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and fair without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty including preparation of new plastered/ unplastered surfaces of wall, complete all as specified & directed by Engr-in-Charge.
Preparation of surfaces by complete removal of existing treatment from old decorated plastered or unplastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer and applying 1mm thick wall care putty on walls to give uniform surface, complete all as specified and as directed by Engr-in-Charge.
Preparing of old decorated surfaces of ceiling, chajjas, etc. by brooming down or steel wire brushing, scrapping down smoke soots, moulds, efflorescence salt, treading oil, greasy spots or washing rubbing down and applying two coats of white wash on ceiling, complete all as specified and as directed by Engr-in-Charge.
Preparing of old decorated surfaces of wall, chajjas, etc. by brooming down or steel wire brushing, scrapping down smoke soots, moulds, efflorescence salt, treading oil, greasy spots or washing rubbing down and applying two coats of cement base paint over a coat of chalk whiting complete all as specified and as directed by Engr-in-Charge. Note: the height of bldg is G+3.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of chalk whiting, complete all as specified and as directed by Engr-in-Charge. Note: the height of bldg is G+3.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Preparation new surfaces plastered or unplastered and applying three coats of white wash on ceiling all as specified
Stainless steel sink, (with drainage board) 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm, fixed in repairs, complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt. ) , complete all as specified and directed by Engineer-in Charge.
Solid PVC door frame of size 50mm x 47mm made out of 5mm wallnut colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings complete all as specified.
Factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded wallnut colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site complete all as specified.
Powder coated (of approved colour ) aluminium sections as in frame & shutter of doors, windows (sliding), ventilators (louvers/fixed type) and fixed frame, incl rollers and locking arrangements with all fittings etc fixed to wall including, preparation of disturbed portion both side (internal & external surfaces of wall) match with existing surface treatment and all sides of aluminium frame shall be sealed with silicon sealent (inner/outer face) complete all as specified as directed by Engr-In-Charge. Note: Actual weight of the aluminium sections used shall be measured for payment purpose and rates also inclusive for the forgoing included". Nothing extra shall be paid
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed.
Preparation of new steel surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide chrome primer, complete all as specified and as directed by Engr-in-Charge.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
5mm Sheet glass, tinted/ frosted as approved quality and glazing with EPDM rubber neoprene packing for aluminium doors/windows in square/rectangular exc 0.5 sq. m in each pane, complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 65 above but frame size 105 x 60 mm.
35mm thick flush shutters, solid core construction, with block board core and plywood face pannels and one face is covered with decorative face veneer with liping/frame to match and polished on back side of shutter complete all as specified and directed by Engineer-in charge.
35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete, all as specified and directed by Engr in Charge.
150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
200 mm aluminium bow handles, cast type anodised complete all as specified and directed. (ISI Mark)
300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete, all as specified. (ISI Mark)
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, 140mm overall length of cover plate complete all as specified and directed. (ISI Mark)
Mild steel, 150 mm, ordinary pattern helical door spring including roller and roller plate fixed to wooden or steel frames with welding/fitted with screws etc., complete all as specified.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and as directed by Engr-in-Charge.
18/19mm thick Prelaminated MDF board, termit proof, chemically well pressed, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, as in kitchen cabinet, cub boards, etc including 6mm thick teak wood beading all around complete all as specified and as directed by Engr-in-Charge.
Continuous (piano) hinges width of flaps (when open) 30 mm, mild steel, bright finish or electrogalvanised, complete all as specified and directed.
Stainless steel handle, fancy type, 150mm fixed with stainless steel screw complete all as specified.
Magnetic ball catches with 8mm dia steel balls and brass body and striking plate including letting in and fixed complete all as specified and as directed.
CP brass tubular towel rail, 20mm dia, D type, 60cm long between flanges aluminium anodized, fixed with rawl plugs. complete all as specified in repairs. (ISI Mark)
CP brass towel ring (round), fixed with rawl plugs. complete all as specified in repairs.
Plate rack made of 1 mm thick stainless steel, of size 600 x 750X250mm including fixing as per manufacturers instruction complete all as specified.
Dismantling loose/disintegrated portion of RCC chajjas, bends, shelves, beams, balconies and similar work at any position or any height and dubbing out with PCC 1:1.5:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished required shape including applying anti corrosive paint on exposed surfaced and provision of necessary support form work and including 10mm thick plastering in CM 1:4 finished fair and even completed all as specifed
75mm PVC (SWR) floor trap with stainless steel grating including jointing with solvent cement, including taking down old PVC or CI floor trap of any type complete all as specified and as directed.(ISI Mark)
75mm PVC (SWR) multi floor traps with stainless steel grating including jointing with solvent cement, including taking down old PVC or CI floor trap of any type complete all as specified and as directed.(ISI Mark)
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down existing WPT complete incl brick tile padding/PCC padding, tarfelt, plastering etc complete and removing the spoil out side MD land and brushing neat cement slurry @ 3 kg/Sqm including 10mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately) and applying bituminous primer on prepared roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide APP (Atactic Polypropylene) Modified Polymeric Membrane five layred prefabricated waterproofing membrane with thermal fusible propertise on both side having minimum 3 mm thick and unit weight not less than 3.5 Kg/Sqm , reinforced with non-woven spun bonded polyester reinforcement < (-) 2ºC cold flexibility.The layer of the membrane shall be laid using butane torch and sealing all joints properly , leaving no bare edges or end of APP membrane and finishing the surfaces with trowel or otherwise to obtain a uniform surfaces. The minimum end overlap shall be kept 15 cms and side lap 75 mm respectively.
Srl item No 86 Contd … The membrane shall be laid over a coat of bituminous primer @ 0.3 Ltr/ Sqm made by the same membrane manufacture after necessary surface preparatory works such as cleaning the surfaces thoroughly, shaping mouth of outlets including cutting grooves (50 x 50 mm) in parapet and inserting edges of membrane and making good damages in cement and sand (CM) 1:4 , complete all as directed by Engr-in- Charge. Note : water proofing treatment shall be done only by the manufacturer of APP membrane or through their authorized agency/ applicator which will further have to rectify defects occur within defect liability periods.
M&L for laying PCC tile 300x300x25mm on roof surface over 15mm thik CM (1:4) mixed with 5% creosote oil, jointed & pointed with 5mm joints filled with polymer modified cement mortar Renderoc S2 or Sika 122 WL complete all as specified and as directed by Engineer-in charge.
Supply only Integral water proofing compound, complete all as specified and as directed by Engr-in-Charge.
Machine cut kota stone slab flooring 18-20 mm thick, bedded jointed and pointed with grey cement slurry including cutting and polishing over and including Screed bed or bedding layer of mortar 20mm thick in cement mortar 1:3, complete all as specified. Note: white/green marble 18-20 mm thick machine cut, 80 mm wide border/strip along the wall shall also be provided & quoted rate shall deem to be inclusive for the same.
Machine cut kota stone slab flooring 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified.
Machine cut kota stone slab flooring 20-25 mm thick in riser of steps in one piece with bull nose, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified.
75 mm thick plain cement concrete (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foudation, filling, sub base and mass concrete all as specified.
Providing, pre-cast cement concrete 1:2:4 type B-I (20mm graded) as in kerb stones and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed by Engr-in-Charge.
Machine pressed / vibro mechenically floated coloured interlocking cement concrete paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of cement with imported pigment including 30 mm thick sand cushioning bed including spreading levelling watering if required, Shape shall be approved by Engr-in-Charge.
32mm size Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms) fixing in repair, complete all as specified and as directed by Engr-in-Charge.
High density polyethylene (HDPE) pipes of pressure rating 6 kgf/sq. cm, complete all as specified and directed by Engr-in-Charge
Stainless steel multipurpose basket in wooden drawer/partitions for storing rations of various types made of 4mm dia stainless steel rods, fixed in side partitions etc for modular kitchens, fixed in position and directed by Engineer-in-Charge.
Stainless steel zero crank hinges (auto) fancy type (with Euro concealed hinges) fixed to shutters in cupboards of standard size and shape for modular kitchens, fixed in position and directed by Engineer-in-Charge.
Telescopic drawer side channel of standard size including rollers for moving drawer, mild steel bright finish, or electrogalvanised, for modular kitchen, fixed in position and directed by Engineer-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / bell /exhaust fan controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 102 above but one 3/5 pin 5 Amp socket outlet on the same board with other switch.
Description all as per item above No 102 but one 3/5 pin 5 Amp socket outlet on independent board .
Description all as per item No 102 above but for light point controlled by 2-two way switch
Description all as per item No 102 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 4 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 4 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Switch piano flush button single pole one way 5 Amp, 240 Volts, complete all as specified and as directed by Engr-in-Charge.
Switch piano flush button single pole two way 5/6 Amp, 240 Volts, complete all as specified and as directed by Engr-in-Charge.
Socket outlet 2 in 1 , 3 pin 5 Amp 240 Volts complete all as specified and as directed.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 & 15/16 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Bell push 6 Amps 230 volts complete all as specified and as directed by Engr-in-Charge.
Bell (ding dong type), AC electronic type, 230 volts, single pole ,fixing in repairs, complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Decorative ultra slim linear surface mounted LED lighting fixture (2 feet length), 10 Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 100 lm/W (e) System Lumens : Not less than 1000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Decorative ultra slim linear surface mounted LED lighting fixture (1 feet length), 5 Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Polycarbonate/Thermoplastic (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 90 lm/W (e) System Lumens : Not less than 450 lm (f) Colour Temperature : Not less than 6500K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Environmental friendly, energy saving, surface mounted, decorative LED 10 Watt Bulk head luminire, with integral electronic LED driver with APFC and lower THD, Output complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following :- (a) Housing of Light fitting : Die Cast Aluminium (b) Diffuser : Polycarbonate UV protected diffuser (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 900 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4kV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Taking down carefully by unscrewing from board/ false ceiling fitting and fixture such as ceiling round light octane led panel, city 3 light, led tube light, enterance light , foot lamp and led bulkhead light fitting, etc for reuse at site or carrying to the store (to be measured only when found serviceable in all respect complete for re use) all as specified and as directed by Engr-in-Charge.
Fixing only serviceable light fittings of any type or any watt obtained against item no.118 all as specified and directed by engineer incharge.
Taking down old serviceable/ unserviceable Electric meter including meter box from existing position carefully refixing including making good to disturbed surfaces , complete all as specified and as directed by Engr-in-Charge.
Taking down fan, ceiling cable end, dismantling blades and removing fan and blades to store, and applying two coats painting with synthetic enamel to ceiling fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 3 core flexible cable from ceiling rose to fitting including rapair ceiling fan 1200mm sweep, oiling, greasing cleaning slot, over hauling & replacement of defective nut bolts washer etc, and rehanging all as per the directions of Engg-in-Charge.
Fan regulator 120W, 230V 50 C/S, flush type electronic, step type hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, including taking down existing Sub main wiring complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Supply and fixing sheet metal enclosures for DBs when MCCBs to be used double door DB VTPN 8 ways 415 volts with 250 Amps rated bus double door type with IP-54, IK-49 protection with appropraite size bus bar and neutral link fixed flush in wall including cutting chases in walls for fixing DB and making good disturbed wall surfaces to match the existing specifiactions fixed in repair, complete all as specified and as directed by Engr-in-Charge.
MCCB 4 pole, 415 volts 250 Amps with breaking capacity 36 KA with thermal adjustble, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-54, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
MCB SP, 6 to 32 Amps, 240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
MCB SP, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
MCB SPN, 32 to 63 Amps, 240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 95 sqmm 3.5 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 137 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Alishan Builders
M/S IMTESH BHAT
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .