Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAdmitted-Finance | ₹1.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.1 Cr+₹3.7 L (3.59%)Admitted-Finance | ₹1.1 Cr+₹3.7 L (3.59%) | L2 | Admitted-Finance |
| 3 | L3₹1.3 Cr+₹29.7 L (28.4%)Admitted-Finance 303 MAHESH NANGIA 303 PRAGATI CHAMBERS RANJIT NAGAR COMMERCAIL COMPLEX RANJIT NAGAR COMMERCIAL COMPLEX | ₹1.3 Cr+₹29.7 L (28.4%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not Qualified as per NIT and SBD |
| Sl No | Description | Qty | Unit | HITECH ERECTORS PVT. LTD. L3 | Trade Linkers Associates L2 | AJAY CONSTRUCTION L1 |
|---|---|---|---|---|---|---|
| 1.00Design, Engineering. Manufacture,workshop testing, supply including packing and forwarded, transportation, delivery at site storage charges of Main Equipment:- | ||||||
| 1.01 | 3 pole, SF6 gas filled, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (145KV, 1600 Amps of 3 phase,50 c/s and 31.5KA for 1 second). | 1 | No. | 8,33,264 ₹8,33,264 | 8,90,000 ₹8,90,000 | 8,00,000 ₹8,00,000 Lowest |
| 1.02 | 145kV, 50c/s , 2000 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing blades | 6 | Set | 5,96,046 ₹35,76,276 | 3,50,000 ₹21,00,000 | 3,10,000 ₹18,60,000 Lowest |
| 1.03 | 145kV, 50c/s , 2000 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing blade | 3 | Set | 6,41,088 ₹19,23,264 | 3,70,000 ₹11,10,000 | 3,60,000 ₹10,80,000 Lowest |
| 1.04 | Single phase, 50 c/s 145KV Current Transformers (1200-600-300/1-1-1-1-1 A or as per site specifications), 31.5KA for one second, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA | 9 | Nos. | 2,17,700 ₹19,59,300 | 2,15,000 ₹19,35,000 | 1,93,984.88 ₹17,45,863.88 Lowest |
| 1.05 | Single Phase 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries. | 6 | Nos. | 66,061 ₹3,96,366 | 50,000 ₹3,00,000 Lowest | 57,477 ₹3,44,862 |
| 1.06 | Single phase, 50 c/s 132KV Capacitor Voltage Transformers (132/√3) KV/(110/√3)V, One min power freq withstand 275KVrms | 3 | Nos. | 2,10,193 ₹6,30,579 | 2,25,000 ₹6,75,000 | 2,01,169.5 ₹6,03,508.5 Lowest |
| 1.07 | 33KV VCB (36 KV, 1250 Amps of 3 phase, 50 c/s and 25KA for 3 sec) outdoor type with all accessories and auxiliaries | 3 | Nos. | 37,534 ₹1,12,602 Lowest | 3,55,000 ₹10,65,000 | 3,16,123.5 ₹9,48,370.5 |
| 1.08 | Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 25KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA | 9 | Nos. | 89,332 ₹8,03,988 | 85,000 ₹7,65,000 | 64,661.63 ₹5,81,954.63 Lowest |
| 1.09 | Single Phase 36KV 50 c/s, outdoor metal oxide gapless type, 36KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries. | 3 | Nos. | 21,770 ₹65,310 | 17,000 ₹51,000 | 9,340.01 ₹28,020.04 Lowest |
Tender Value
₹1.0 Cr
EMD Value
₹2.0 L
Closing Date
10 Jul 2023, 4:00 pmClosed
Executive Engineer TLMD-II, JKPTCL, Gladni Jammu
Office of the Executive Engineer TLMD-II, JKPTCL, Gladni Jammu
Replacement of old and worn out equipment such as Circuit breakers, isolators, Current transformers and Lightening Arrestor etc in 132 KV and 33 KV yard at 710 MVA, 220/132/33 KV Grid station Gladni
2023_PDD_217304_1
TLMD-II/J/13 of 2023-24 Dated 17-06-2023
Open Tender
Electrical Works
Turn-key
180 days
Gladni Jammu
As per NIT and SBD
3 documents required · 3 mandatory
₹10,000
Executive Engineer TLMD-II, JKPTCL, Gladni Jammu
₹2.0 L
28 Aug 2023
17 Jun 2023
13 Jul 2023
17 Jun 2023
10 Jul 2023
19 Jun 2023
Amount
Design, Engineering. Manufacture,workshop testing, supply including packing and forwarded, transportation, delivery at site storage charges of Main Equipment:-
3 pole, SF6 gas filled, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (145KV, 1600 Amps of 3 phase,50 c/s and 31.5KA for 1 second).
145kV, 50c/s , 2000 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing blades
145kV, 50c/s , 2000 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing blade
Single phase, 50 c/s 145KV Current Transformers (1200-600-300/1-1-1-1-1 A or as per site specifications), 31.5KA for one second, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA
Single Phase 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
Single phase, 50 c/s 132KV Capacitor Voltage Transformers (132/√3) KV/(110/√3)V, One min power freq withstand 275KVrms
33KV VCB (36 KV, 1250 Amps of 3 phase, 50 c/s and 25KA for 3 sec) outdoor type with all accessories and auxiliaries
Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 25KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA
Single Phase 36KV 50 c/s, outdoor metal oxide gapless type, 36KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Blades
Single phase, 50 c/s outdoor 33KV PT (33/√3) KV/ (110/√3)V with Highest System Voltage36KV, One min power freq withstand 70KVrms
DISMANTLING OF EQUIPMENTS
3 pole, SF6 gas filled, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (145KV, 1600 Amps of 3 phase,50 c/s and 31.5KA for 1 second).
145kV, 50c/s , 2000 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing blades
145kV, 50c/s , 2000 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing blade
Single phase, 50 c/s 145KV Current Transformers (1200-600-300/1-1-1-1-1 A or as per site specifications), 31.5KA for one second, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA
Single Phase 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
Single phase, 50 c/s 132KV Capacitor Voltage Transformers (132/√3) KV/(110/√3)V, One min power freq withstand 275KVrms
33KV VCB (36 KV, 1250 Amps of 3 phase, 50 c/s and 25KA for 3 sec) outdoor type with all accessories and auxiliaries
Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 25KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA
Single Phase 36KV 50 c/s, outdoor metal oxide gapless type, 36KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Blades
Single phase, 50 c/s outdoor 33KV PT (33/√3) KV/ (110/√3)V with Highest System Voltage36KV, One min power freq withstand 70KVrms
Handling, Storage, Preservation, Erection (except civil works), Testing & Commissioning of following Equipments:-
3 pole, SF6 gas filled, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (145KV, 1600 Amps of 3 phase,50 c/s and 31.5KA for 1 second).
145kV, 50c/s , 2000 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing blades
145kV, 50c/s , 2000 Amp, 31.5kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing blade
Single phase, 50 c/s 145KV Current Transformers (1200-600-300/1-1-1-1-1 A or as per site specifications), 31.5KA for one second, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA
Single Phase 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
Single phase, 50 c/s 132KV Capacitor Voltage Transformers (132/√3) KV/(110/√3)V, One min power freq withstand 275KVrms
33KV VCB (36 KV, 1250 Amps of 3 phase, 50 c/s and 25KA for 3 sec) outdoor type with all accessories and auxiliaries
Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 25KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA
Single Phase 36KV 50 c/s, outdoor metal oxide gapless type, 36KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Blades
Single phase, 50 c/s outdoor 33KV PT (33/√3) KV/ (110/√3)V with Highest System Voltage36KV, One min power freq withstand 70KVrms
CIVIL WORKS
Dismantling of foundation of existing SF6 breaker & Vaccum Circuit Breakers including removal of extra debris from the site
Laying of foundations for SF6 Circuit breaker & VCB's as per Standard Approved drawing as per design
Manual/mechanical carriage of dismantled material for disposal at suitable dumping site outside Grid station premises
Note:- All civil works shall be carried out as per approved Drawings and payment on account of all Civil works shall be made as per actual measurements at site.
Trade Linkers Associates
HITECH ERECTORS PVT. LTD.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.40 MB
SBD.pdf
Tender Documents • 1.46 MB
BOQ_591876.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .