| 1 | L1₹35.7 LAccepted-AOC NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹39.7 L+₹2.9 L (7.87%)Rejected-Finance 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹44.6 L+₹7.8 L (21.2%)Rejected-Finance 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹44.7 L+₹7.9 L (21.5%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to not have approved category i.e c(i). |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
18 Feb 2023, 6:00 pmClosed
GE (UTILITY) UDHAMPUR
GE (UTILITY) UDHAMPUR, PO-GARHI, PIN-182121
Repair/Maint of summer appliances, laundry plant, preventive comprehensive maint and allied works at certain different locations under GE(Utility) Udhampur
2023_MES_577822_1
GE/U- /2022-23
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (UTILITY) UDHAMPUR
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (UTILITY) UDHAMPUR
₹97,000
Yes
31 Mar 2023
28 Jan 2023
20 Feb 2023
28 Jan 2023
18 Feb 2023
11 Feb 2023
Amount
Supply and topping up of refrigerant gas R-410A in Split air conditioner of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-Charge.
M/L for Sub main wiring with 2 Run of 4 Sqmm cable and one run of 2.5 sqmm PVC insulated, unsheathed FR cable of multi-stranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non-metallic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories concealed on wall and surface on ceiling complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB distribution board single pole and neutral 8 way factory made sheet steel, phosphates, powder painted with 100 Amps rated busbar, 240 volts, neutral link, earth bar and Din rail double door complete including taking down/dismantling of old unserviceable one complete all as specified and directed by Engr-in-Charge.
Repairing /Servicing and rewinding of motor 3 phase 400-440 volt complete disconnecting the electric supply removing of pully and fan and opening of both end covers taking out Bearings and rotor checking of air gap, checking of rotor field winding, replacement of bearings, greasing fo bearings including rewiring with superior quality copper winding wire insulating material, vanishing binding of winding etc complete all as directed by Engr -in-Charge reassembling, replacing rusted nut, bolts, washers, checking and adjusting the alignment, connecting electric connection completed all as specified and directed. For the following :-
Electric motor 3 phase 10 HP of AC Plant.
Electric motor 3 phase 5 HP of AC Plant.
Repairing/ servicing of monoblock water pumping set capacity 5.0 HP including removing of old gland packing, gland bolt and fixing of new gland packing , gland bolt, cleaning of impeller/Replacement of impeller complete all as specified and directed by Engr-in-Charge.
Descaling of condenser after opening of both end cover, circulation of descaling solution forcibly using pump for 10 TR capacity condenser circulating decaling solution and rubbing manually using nylon brush of size 1/4,3/8,1/2,5/8 inch descaling rod etc without damaging copper tubing and re-fixing of side cover using new gasket of rubber insulation sheet of 3mm thick and replacement of rusted nuts bolts etc complete all as specified and directed by Engr-in-Charge.
Descaling and flushing of cooling coil of 10 TR capacity plant complete with chemical, bends and cleaning complete all as specified and directed by Engr-in-Charge.
Repairing serving of cooling coil tower of AC plant of 10 TR capacity (1 FOD) FRP Type by dismantling ad taking out the one comb PVC files complete ad PV Nozzles the PVC files by suitable descaling solution including bruising and cleaning complete with cleaning solution and water replacing the defective PVC flange along with rubber gasket and rusted bolts nuts and washer etc cleaning the water sump ad XMP wire mesh with suitable cleaning solution re-assembling the same including replacing the defective water filter flanges of pipe joints etc and testing complete all as specified and directed (PVC Files will be measured ad paid separately for the following:- 10 TR Capacity plant installed at 1 FOD A/C Plant.
Supply and fixing in replacement of 32 Amp,3pole, 415 Volts, 50 Hz Power contactor (MNX32) auxiliary contact 2 NO + 2 NC, of coil voltage 440 Volts, complete all as specified and directed by Engr-in-Charge. Make: Model No CS 94111 L&T/ Schineider/Havells.
MCCB Three pole 415 Volt 50 Hz 160 Amps wit breaking capacity 25 KA type DT complete all as specified and directed by Engr-in-Charge. Make: L&T/ABB/SCHNEIDER/ SIMESE.
MCCB Three pole 415 Volt 50 200 Amps with breaking capacity 25 KA type complete all as specified and directed by Engr-in-Charge. Make: L&T/ABB/SCHNEIDER/ SIMESE.
Over load relays MK 1 Type relays range 44 to 75 Amps complete all as specified and directed by Engr-in-Charge. Make: L &T/Autoix/MDS/SIMEMS or Equivalent.
Over load relays MK 1 Type relays range 14 to 23 Amps complete all as specified and directed by Engr-in-Charge. Make: L&T/Autoix/MDS/SIMEMS or Equivalent.
Supply & fix HEPA filter 10 to 20 microns static wove both side DPE mesh in aluminium frame efficiency 90% of sizes as per site requirement complete all as specified and directed by Engr-in-Charge.
Supply & fix factor made performance HEPA filters of 99 micro down to 5 micro of standard size with multiple pockets & self supporting filters bags with MS/GI anodised aluminium frame suitable for central AC Plant including replacement of bolts & nuts & taking down unserviceable complete all as specified and directed by Engr-in-Charge.
Provide skilled technician for attending of any breakdown of VRF type AC Plant of capacity 25 HP / 16 HP whenever required round the clock ,rectify the fault and restart the plant within three hour after receipt of complaint of any nature i.e. Compressor, Condenser, control panel etc complete all as specified and directed by Engr-in-Charge. Note -(i) The cost of replaced spare parts will be paid and measured separately. (ii) If complaint is not attended by contractor with in five hour the penalty of Rs 500 / per hour to be imposed and amount of penalty will be deducted fromRAR. (iii) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock.
M&L for serving of air VRF type AC Plant of capacity 24 HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasket complete all as specified and directed by Engr-in-Charge. Note:-Necessary Nut, Bolts, washers, pickings are included in quoted rate.
M&L for serving of air VRF type AC Plant of capacity 20 HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasket complete all as specified and directed by Engr-in-Charge. Note:Necessary Nut, Bolts, washers, pickings are included in quoted rate.
M&L for serving of air VRF type AC Plant of capacity 16 HP by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasket complete all as specified and directed by Engr-in-Charge. Note: Necessary Nut, Bolts, washers, pickings are included in quoted rate.
M&L for serving of air VRF type AC Plant of capacity 16 TR by opening of both side cover taking out the Fresh air filter cleaning the outdoor & Indoor unit, Primary air filter, and re-fixing the side covers head covers after replacing the suitable gasket complete all as specified and directed by Engr-in-Charge. Note: Necessary Nut, Bolts, washers, pickings are included in quoted rate.
M&L for serving of air Handling Unit of capacity 10 TR by opening of both side cover taking out the Fresh air filter cleaning the External & Internal surface of AHU, Primary air filter, wire mesh filter, Tumble Blower fan and re-fixing the side covers head covers after painting & necessary welding including replacing the suitable gasket complete all as specified and directed by Engr-in-Charge. Note: Necessary Nut, Bolts, washers, pickings are included in quoted rate.
Supply, installation testing & commissioning of variable refrigerant Y joint required for distribution of refrigerant copper piping etc., complete as per specifications flow distribution REFNETS (Y-Joints) in the suction & liquid lines complete all as specified and directed by Engr-in-Charge.
Supply, installation testing & commissioning of refrigerant copper piping insulated with 19 mm / 13 mm thick Nitrile rubber of following sizes between outdoor unit to indoor units as per the specifications. The refrigerant pipe shall be hard drawn /soft drawn copper pipe as per manufacture recommendations. The quantity of these items of works recommendations. The quantity of these items of works shall be measured as per actual requirement of site conditions The vendor shall accept the accepted rate as per the actual measured quantities. The size of refrigerant pipes shown below are tentative, measured quantities.The size of refrigerant pipes shown below are tentative.The required size of pipe shall be designed by the vendor as per the manufacturer recommendations:-
41.28 mm OD (Insulation 19mm thick).
28 mm OD (Insulation 19mm thick).
22 mm OD (Insulation 19mm thick).
15.9 mm OD (Insulation 19mm thick).
9.5 mm OD (Insulation 19mm thick).
Supply & Fix in replacement PVC sheathed Twin core Aluminium conductor cable 6 sqmm complete all as specified and directed by Engr-in-Charge.
Supply & Fix in replacement PVC sheathed Twin core Aluminium conductor cable 4 sqmm complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable metal plug socket and supply and fix new metal plug and socket board complete enclosure with single pole and neutral and earth plug with MCB SP 32/40 Apms, 220 Volts complete suitable for window/Split type complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable DB two way and MCB SPN-40 Amps and supply and fix sheet metal enclosure with DBs single pole and neutral two way 240 Volts by with one SPN MCB of capacity 40 Amps complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable front show grill and supply and fix new front show grill for LG/Voltas /Sidwal/Godrej window type AC 1.5 Ton complete all as specified and directed by Engr-in-charge (as per sample approved by GE).
Taking out old existing reversible type unserviceable inner unit of split type AC of capacity 1.5/2.0 Ton and supply and fix new inner unit of split type AC of capacity 1.5 /2.0Ton as existing shape, size and make complete all as specified and directed by Engr-in-Charge. Make : Godrej, Carrier, Bluestar, Voltas.Hitachi.LG.
Taking out old existing reversible type unserviceable outer unit of split type AC of capacity 1.5/2.0 Ton and supply and fix new outer unit of split type AC of capacity 1.5 /2.0Ton existing shape and size without compressor complete all as specified and directed by Engr-in- Charge. Make :Godrej, Carrier, Bluestar, Voltas.Hitachi.LG.
Disconnecting from electrical system carrying to workshop & back to store/site after repair dismantling the voltage stabilizer of capacity 7.5KVA, 5KVA, 2KVA, 1KVA, 0.5KVA throughly checking, cleaning all parts by brushing and re-assembling after repalcement of required burnt unserviceable parts / componenets, testing and comminssioning complete after necessary repair/replacement of components as below:-
Rewinding of main coil (primary/secondary) with super enameled copper wire of existing size including varnishing and insulation material of capacity 7.5KVA.
All as per serial item No.31.01 here-in-before but for DG set of capacity 5KVA.
All as per serial item No.31.01 here-in-before but of capacity 2KVA.
All as per serial item No.31.01 here-in-before but of capacity 1KVA.
All as per serial item No.31.01 here-in-before but of capacity 0.5KVA.
Replacement of unserviceable relay for 7.5KVA & 5KVA,30amp 24volts DC.
Replacement of unserviceable Step down transformer 24 volts 2Amp for 5 KVA & 7.5KVA.
Replacement of unserviceable circuit plate with connection wire.
Replacement of unserviceable relay for 0.5KVA, 1KVA & 2KVA,16amp 24volts DC.
Replacement of unserviceable Voltmeter 0- 300V, AC 75 Sqm.
Replacement of unserviceable Ampre meter 0- 30Amp, AC 75 Sqm.
Replacement of unserviceable push switch.
Replacement of unserviceable time delay circuit.
Replacement of unserviceable connector switch 30amp 220volts AC.
Replacement of unserviceable 3pin socket 5Amps,240volts.
Replacement of unserviceable 3pin socket 15Amps,240volts.
Water tap internal threaded /external threaded suitable for water cooler complete all as specified and directed by Engr-in - Charge.
Taking out old existing unserviceable cooling coil and supply and fix new cooling coil of existing shape and size suitable for 1.5/2 Ton Split/Window type AC complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable condensing coil and supply and fix new condenser coil of existing shape and size suitable for 1.5/2Ton Split/Window type AC complete all as specified and directed by Engr-in-Charge.
Repair/replacement PCB for LG /Voltas/Loyed/Hitachi/Godrej window type AC 1.5 ton / 2Ton capacity complete all as specified and directed by Engr-in-Charge.
Repair/replacement PCB for LG /Voltas/Hitachi/Loyed/Godrej split type AC 1.5ton/2Ton cap complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable coil Senser and supply and fix new coil senser of existing shape and size suitable for 1.5/2 Ton Split Type AC complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable heating senser and supply and fix new senser of existing shape and size suitable for 1.5/2 Ton Split Type AC complete all as specified and directed by Engr-in-Charge.
Taking out old unserviceable blower and supply and fix new blower(plastic body) of 1.5/2.0 Ton Split/Window type AC (as per sample approved by GE) complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-22 in Split air conditioner of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-410/32 in Split air conditioner of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-600 in Referigerator complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-134 in Water Cooler and Referigerator complete all as specified and directed by Engr-in-Charge.
L -Shape thimble brass in pk(50Nos in one pkt) (in replacement) complete all as specified and directed by Engr-in- Charge.
Thimble brass(50Nos in one pkt) (in replacement) suitable for all type of AC,Water cooler, Referigerator,Deep freezer in pkt complete all as specified and directed by Engr-in-Charge.
Reverse cycle valve (in replacement) for window type AC/ Split Type AC of capacity 1.5 Ton /2.0 Ton including welding, brazing complete all as specified and directed by Engr-in-Charge.
Flexible drain pipe for Window type/Split Type AC of any capacity complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable one and supply and fix new swing motor 0.3HP, 220 volts complete with Louvers, base ,clamps, nuts, bolts of size/shape suitable for 1.5/2.0 Ton Splt/window type AC of capacity 1.5 Ton complete all as specified and directed by Engr-in-Charge. Make:- LG/Voltas/Hitachi/Godrej.
Taking out old existing unserviceable one and supply and fix new hermetic/Rotary sealed unit compressor(rotary type) suitable for window type/split type ACs of capacity 1.5 ton and making connection to suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per latest new model of same manufacturer with same specifications conforming to original compressor including recharging with refrigerant F-22 , Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system complete all as specified and directed by Engr-in-Charge. Make-LG/Godrej/Hitachi/universal
Taking out old existing unserviceable one and supply and fix new inverter model sealed unit compressor (rotary type) suitable for window type/split type ACs of capacity 1.5 ton and making connection to suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per latest new model of same manufacturer with same specifications conforming to original compressor including recharging with refrigerant R-32/410, Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system complete all as specified and directed by Engr-in-Charge. Make-LG/Godrej/Hitachi/universal.
Taking out old existing unserviceable one and supply and fix new hermatic/rotery sealed unit compressor suitable for window type/split type ACs of capacity 2 ton making connection to suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per latest new model of same manufacturer with same specifications conforming to original compressor including recharging with refrigerant F-22, Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system complete all as specified and directed by Engr-in-Charge. Make-LG/Godrej/Hitachi/universal.
Taking out old existing unserviceable one and supply and fix new inverter model sealed unit compressor (rotary type) suitable for window type/split type ACs of capacity 2 ton and making connection to suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per latest new model of same manufacturer with same specifications conforming to original compressor including recharging with refrigerant R-32/410 , Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system complete all as specified and directed by Engr-in-Charge. Make-LG/Godrej/Hitachi/universal.
Taking out old existing unserviceable one and supply and fix new hermitically /Rotary sealed unit compressor and making connection of suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per existing unit of latest new model of same manufacture with same specification conforming to original compressor including recharging with refrigerant gas F-22/R-134A,R-600, Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and changing parts with gas brazing and leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system all as directed by Engr-in-charge for the following sealed units pertaining to Water coolers, refrigerator and deep freezers:-
New sealed unit (compressor) in original suitable for Water cooler of capacity 40/80 Ltr complete all as specified and directed by Engr-in-Charge. Make – Godrej / Blue Star /Voltas
New sealed unit (compressor) in original suitable for Water cooler of capacity 60/120 Ltr complete all as specified and directed by Engr-in-Charge. Make – Godrej / Blue Star /Voltas.
New sealed unit (compressor) in original suitable for Water cooler of capacity 150/180 Ltr complete all as specified and directed by Engr-in-Charge. Make – Godrej / Voltas /Blure Star.
New sealed unit (compressor) in original suitable for 165/170 Ltr Refrigerator, complete all as specified and directed by Engr-in-Charge. Make - Godrej /LG/Voltas.
New sealed unit (compressor) in original suitable for 270 to 290 Ltr Refrigerator, complete all as specified and directed by Engr-in-Charge. Make - Godrej /LG/Voltas.
New sealed unit (compressor) in original suitable for more than 310 Ltr Refrigerator, complete all as specified and directed by Engr-in-Charge. Make - Godrej /LG/Voltas
New sealed unit (compressor) suitable for 320 litres Deep Freezers in original, complete all as specified and directed by Engr-in-Charge. Make : Godrej /Voltas/Blue Star
In replacement and testing of complete new Fan Motor 1/16 HP single shaft for water cooler of same model and type, single phase 230V complete with base and clamps, nuts, bolts main lead as required etc against burnt defective motor complete all as specified and directed by Engr-in-Charge. Make: Air master/Crompton.
Fan motor1/20 HP single shaft for water cooler as per the original make of fan motor complete all as specified and directed by Engr-in-Charge. Make: Air master /Crompton
Fan Motor 1/35HP single shaft for water cooler complete all as specified and directed by Engr-in-Charge. Make: Air master/Crompton
Fan Motor 1/70HP single shaft for water cooler side holder, bushes with main lead complete all as specified and directed by Engr-in-Charge. Make: Air master/Crompton
Fan motor with fan suitable for LG double door 286 ltr / 310 Ltr refrigerators (in replacement) complete all as specified and directed by Engr-in-Charge.
Fan motor of 165/170 Litre Refrigerator and supply and fix new fan motor of existing make, shape and size (in replacement) directed by Engr-in-Charge.
All as perial Serial item No 67.00 here-in-above but suitable for single door 310 litre Refrigerator complete all as specified and directed by Engr-in- Charge .
Taking out old unserviceable Condensing coil for 165/170 to 310 Litre Referigerator and supply and fix new condenser coil of existing make shape and size complete all as specified and directed by Engr-in-Charge.
Fan Motor (in replacement) of same model and type, single phase 230V complete with base and clamps, nuts and bolts of suitable size etc. against burnt/ defective motor of capacity 1/8 HP double shaft for 1.5 /2.0 Ton window type AC including base, frame, side clamps complete all as specified and directed by Engr-in-Charge. Make: Air master/ Crompton.
All as per Serial item No 70.00 here-in-before but Blower Fan Motor single shaft for Split type AC complete with base, clamps, side holders, rubber bushes complete all as specified and directed by Engr-in-Charge. Make: Air master/Crompton.
All as per Serial item No 70.00 here-in-before Fan motor 1/7 HP for cooling coil of Split Type AC as per the original make of split type AC complete with base, frame, clamps, side holders, rubber bushes with main lead suitable for Voltas/ LG complete all as specified and directed by Engr-in-Charge. Make: Air master/Crompton.
Taking out old existing unsv Starting Capacitor of capacity 50+6 mfd and supply and fix new Multi purpose Running Capacitor of capacity 50+6 mfd for window /split type AC complete all as specified and directed by Engr –in- Charge (as per sample approved by GE).
Taking out old existing unsv Starting Capacitor of capacity 120+150 mfd supply & fix new Multi purpose starting Capacitor of capacity 120/150 mfd for window/split AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Starting Capacitor of capacity 40+80 mfd supply and fix new Multi purpose starting Capacitor of capacity 40/80 mfd for water cooler complete all as specified and directed by Engr-in- Charge (as per sample approved by GE).
Taking out old existing unserviceable Starting Capacitor of capacity 40+60 mfd supply and fix new Multi purpose starting Capacitor of capacity 40/60 mfd for water cooer complete all as specified and directed by Engr-in- Charge (as per sample approved by GE).
Taking out old existing unserviceable Starting Capacitor of capacity 80/100mfd supply and fix new Multi purpose Running Capacitor of capacity 80/100 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 45+5 mfd and supply and fix new Multi purpose running Capacitor of capacity 45+5 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 36+6 mfd and supply and fix new Multi purpose running Capacitor of capacity 36+6 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 10 mfd and supply and fix new Multi purpose running Capacitor of capacity 10 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 4 mfd and supply and fix new Multi purpose running Capacitor of capacity 4 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Multi purpose running Capacitor of capacity 20 Mfd and supply and fix new Multi purpose running Capacitor of capacity 20 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable thermostate and supply and fix new thermostate for water cooler of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved d by GE).
Taking out old existing unserviceable Fan Blade and supply and fix new Fan Blade of 1.5/2ton window type AC of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable Fan Blade and supply and fix new Fan Blade of 1.5/2 ton split type AC of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Repair/replacement of water pump motor of desert cooler including electric connection and testing for better performance complete all as specified and directed by Engr-in-Charge.
Replacement of 'T' junction for desert cooler for watering the three side of the desert cooler with nozzels complete all as specified and directed by Engr-in-Charge.
Replacement of Khas khas set for the doors of desert coolers all as directed by Engr-in-Charge.
Servicing of window/split type air conditioner 1.5 TR capacities of any make by opening the indoor/ outdoor unit ,cleaning the air filter, condenser including complete body of the unit with brush and air blower, washing with cleaning detergent & fresh water ,greasing fan motor ,rectification of loose electric connections and replacement of u/s knobs of electrical items complete all as directed by the Eng-in-Charge.
Disconnecting and taking down unserviceable overload/PTC relay for water cooler ,Deep freezer and referigerator and supply and fix new over load relay/PTC relay and testing for water cooler ,Deep freezer and referigerator satisfactory performance commissioning complete all as specified and directed by Engr-in-Charge.
Disconnecting and taking down unserviceable thermostat from split type AC and supply and fix new thermostat for split type AC 1.5/ 2.0 Ton cap AC and testing the same for satisfactory performance complete all as specified and directed by Engr-in-Charge.
Pressure testing and rectifying leakage in the system of window/split air conditioner up to 2 TR capacity including testing for satisfactory performance, commissioning complete all as specified and directed by Engr-in-Charge.
Copper tubing (in replacement) of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump complete all as specified and directed by Engr-in-Charge.
Cleaning of coils of Window/Split by using alkaline based coil cleaner (Non Acid based) including taking down filters, spraying the diluted alkaline based coil cleaner, leaving it for five minutes and then flushing with running water. Fixing back the filters. Testing & re-commissioning etc.,complete all as specified and directed by Engr –in- Charge.
Taking out old existing unserviceable Fan motor 4x4 and supply and fix new Fan motor 4x4 for water cooler of any capacity complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Sub main wiring(in replacement) with two single core PVC insulated, unsheathed copper conductor cable, 1100volts grade of size 4.0 sqmm, FRLS in and including concealed PVC conduit, heavy duty, ISI marked of dia 25mm and thickness not less than 2mm with all accessories such as bends, Tees, elbows, reducer socket, bell mouth,tube ends etc including cutting chases, pinning in masonry walling & making good to facing by pointing / plastering in cement mortar 1:3 to ends or edges for concealed wiring inculding 4.00 sqmm PVC insulated copper conductor cable as earth lead to connecting to the earth dollycomplete all as specified and directed by Engr-in- Charge. Note :- Two run of wire and single run of earth wire 1RM of PVC conduit shall be measured as one unit.
Taking out old existing unserviceable diacharge valve and supply and fix new discharge valve of 1.5/2 ton split type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable suction valve and supply and fix new suction valve of 1.5/2 ton split type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable bush and supply and fix new bush of 1.5/2 ton split type AC make LG/ Voltas complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable capillary and supply and fix new capillary of 1.5/2 ton split type /window type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable dead Nut and supply and fix new dead nut of 1.5/2 ton split type /window type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Taking out old existing unserviceable NRV and supply and fix new NRV of 1.5/2 ton split type /window type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
Remote control unit Suitable for 1.5 / 2.0 Ton split type AC working on both (Hot & Cool) (in replacement) complete all as specified and directed by Engr-in- Charge (as per sample approved by GE) .
Sub main wiring with two single core PVC insulated unsheathed copper conductor cable 1100 volts grade 6.0 Sqmm size HRFR in and including concealed PVC conduit heavy duty ISI marked 25mm dia non metallic with all accessories such as bends, Tees, elbows, reducer socket, bell mouth, tube ends etc. including cutting chases, pinning in masonry walling & making good to facing by pointing/plastering in cement mortar 1:3 to ends or edges for concealed wiring including 4.0Sqmm PVC insulated copper conductor cable as earth lead to connecting to the earth dolly complete all as specified and directed by Engr-in-Charge. Note : Two run of wire and single run of earth wire and 1 RM of PVC conduit shall be measured as one unit.
Repair of Deep frezeer of capacity 320ltr capcity by dismantling the whole condensing as well as cooling coil and finding the leakage /damage portion. Rectify the leakage and damaged parts and vaccume leakage the whole system. Then charging the refrigerent Gas and confriming no leakage. Then reassembling the same deep freezer by providing proper insulation material at the disturbed area complete all as specified and directed by Engr-in-Charge.
Repair /repalcement of broken /water leakage from connection of water cooler of capacity 40/80ltr to 150/150ltrs capcity by dismatiling the front sheet of the water cooler tank, removing the thermocol sheet and doing necessary cutting /welding /brazing work to stop the leakage and make good the damaged portion and fixing of tap connection and reassembling the front sheet including providing the thermocol as a thermal insulation to the water coolers and testing the coolers for no leakage as complete all specified and directed by Engr-in-Charge.
Taking out & re-fixing after repair to roof/building at same location / other location including shifiting where required, of split /window/casttee type AC by making hole, drilling , cutting on wall and necessary gas pipe connection , electric connections and insulations complete all as specified and directed by Engr-in-Charge. Note:- All items including gas, copper pipe and electric cable if required will be measured and paid separately in relevent items of contract.
Supply and fixing flexible drain pipe for water cooler of any capacity any size complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable NRV spare parts from air curtain such as Air curtain motor, Air curtain door sensor, Air curtain blower, blower wheels replacement with new and fix of size complete all as specified and directed by Engr-in-Charge. (as per sample approved by GE).
S&F PVC conduit pipe size 40 mm complete all as specified and directed by Engr-in-Charge.
Taking out okd existing unserviceable foam insulation and supply and fix new foam insulation of 1.5 /2 ton split type /window type AC complete all as specified and directed by Engr-in-Charge. (as per sample approved by GE).
Routine Preventive comprehensive maintenance including necessory cutting, welding, turning job,greassing of movable parts, dismentaling of parts for repair and fixing after repair etc of washing machine 100 Kg capacity-02 Nos steam heated, front loading for washing hospital linen/Garments etc. With drive motor 5HP and extractor 10 HP complete all as specified and directed by Engr-in-Charge.
All as per serial item No 112.00 discribe above but for washing machine 50 Kg capacity-03 Nos With drive motor 3HP and extractor 5 HP, complete all as specified and directed by Engr-in-Charge.
All as per serial item No 112.00 discribe above but for sluicing machine 25 Kgs capacity-02 Nos. Front-loading type open pocket heavy-duty normal spin steam auto reverse etc. complete all as specified and directed by Engr-in-Charge.
All as per serial item No 112.00 discribe above but for Hydro extractor top loading type direct drive self-balancing with automatic DC injection brake automatic timed filled with safety 25 Kg. Dry weight-02 Nos and 50 KG Dry weight-02 Nos complete all as specified and directed by Engr-in-Charge.
All as per serial item No 112.00 discribe above but for drying tumble 25 KG-02 Nos and 50 Kg-02 Nos steam heated front loading type open pocket automatic timed auto reverse auto digital temperature control dry complete all as specified and directed by Engr-in-Charge.
All as per item No 112.00 discribe above but for steam flat bed press model SBF/30/5 make : Super shine Sri Nos 3/2JNDA 233&312 NDA 2436, 2373, 2331 RPM 2820 automatic timer and automatic temperature control steam, heated pneumatic raising and lowering powerful moisture suction of size 750 mm x 1500, Qty-04 Nos complete all as specified and directed by Engr-in-Charge.
All as per item No 112.00 discribe above but for reciprocating air cooled compressor model AED20 and vacuum pump of capacity 5 HP 3 phase double stage model No 4741/KL/4883 with air tank and connection from main board to machine and loop earthing to supply compressed air to three flat work ironer and five bed press, auto calving/mattress sterilizer, complete all as specified and directed by Engr-in-Charge.
Routine Preventive comprehensive maintenance of Diesel operated Steam Boiler capacity 600 Kg/Hrs 02 Nos comprising Blower Motor 2 HP Cap, 3 Phase, Water Pump Motor cap 1 HP, Fuel Pump Cap 0.5 HP. Including descaling of gas chamber, filtter valve, necessory cutting, welding, turning job,greassing of movable parts, dismentaling of parts for repair and fixing after repair etc complete all as specified and directed by Engr-in-Charge.
Complete opening, Cleaning & Servicing of Air Conditioning coil, duct etc of draing tumbler, removing cotton particals and pesting new insulation material in duct including repair of duct complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement for replacement of MS Channel/angle iron/flat iron/ Sheet of required size and bend to shape as requiered including necessory febrication to repair frame structure of machine with replacing bolts, nuts, and washers including painting two coats of synthetic enemel paint (Aluminium shade) over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Repairing /Servicing and rewinding of motor 3 phase 400-440 volt 10 HP of laundry plant complete disconnecting the electric suppply removing of pully and fan and opening of both end covers taking out Bearings and rotor checking of air gap, checking of rotor field winding, replacement of bearings, greasing of bearings including rewiring with superior quality copper winding wire insulating material, vamishing binding of winding etc complete all as directed by Engr -in-Charge reassembling, replacing rusted nut, bolts, washers, checking and adjusting the alignment, connecting electric connection complete all as specified and directed by Engr-in-Charge. Note:- The cost of transportation of electric motor to work shop and back to the site included in quoted rate.
Electric motor 3 phase 7.5 HP of Laundry Plant complete all as specified and directed by Engr-in-Charge.
Electric motor 3 phase 5 HP of Laundry Plant complete all as specified and directed by Engr-in-Charge.
Electric motor 3 phase 3 HP of Laundry Plant complete all as specified and directed by Engr-in-Charge.
Electric motor 3 phase 2 HP of Laundry Plant complete all as specified and directed by Engr-in-Charge.
Electric motor single phase 1 HP of Laundry Plant complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement V belt B-62 complete all as specified and directed by Engr-in-Charge. Make: Fenner/Powerfix/Dunlop.
Supply & fix in replacement V belt B-65 complete all as specified and directed by Engr-in-Charge. Make: Fenner/Powerfix/Dunlop.
Supply & fix in replacement V belt B-70 complete all as specified and directed by Engr-in-Charge. Make: Fenner/Powerfix/Dunlop.
Supply & fix in replacement V belt B-72 complete all as specified and directed by Engr-in-Charge. Make: Fenner/Powerfix/Dunlop.
Supply & fix in replacement V belt B-80 complete all as specified and directed by Engr-in-Charge. Make: Fenner/Powerfix/Dunlop.
Supply & fix in replacement V belt B-85 complete all as specified and directed by Engr-in-Charge. Make: Fenner/Powerfix/Dunlop.
Supply & fix in replacement V belt B-86 complete all as specified and directed by Engr-in-Charge. Make: Fenner/Powerfix/Dunlop.
Supply & fix in replacement V belt B-92 complete all as specified and directed by Engr-in-Charge. Make: Fenner/Powerfix/Dunlop.
Supply & fix in replacement belt B-100 complete all as specified and directed by Engr-in-Charge. Make: Fenner/Powerfix/Dunlop.
Supply & fix in replacement belt B-118 complete all as specified and directed by Engr-in-Charge. Make: Fenner/Powerfix/Dunlop.
Supply and fixing in replacement 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB complete with connection complete all as specified and directed by Engr-in-Charge.
All as per serial item No 138.00 here-in-before but for 40-63 Amp SPN.
All as per serial item No 138.00 here-in-before but for 16-32 Amp TPN.
All as per serial item No 138.00 here-in-before but for 40-100 Amp TPN.
Supply and fixing in replacement of 32 Amp,3pole, 415 Volts, 50 Hz Power contactor (MNX32) auxiliary contact 2 NO + 2 NC, of coil voltage 440 Volts, complete all as specified and directed by Engr-in-Charge. Make: Model No CS 94111 L&T/ Schineider/Havells.
Supply and fixing in replacement of 18 Amp,3pole, 415 Volts, 50 Hz Power contactor (MNX18) auxiliary contact 2 NO + 2 NC, of coil voltage 440 Volts, complete all as specified and directed by Engr-in-Charge. Make: Model No CS 94111 L&T/ Schineider/Havells.
Supply & fix in replacement push button “ ON “ OFF complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement indication lamp complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement limit switch 10 Amps, 415 volts complete all as specified and directed by Engr-in-Charge. Make: Vaishno/L&T
Supply & fix in replacement steam globe valve 15 mm ISI Mark complete all as specified and directed by Engr-in-Charge. Make: Vaishno/L&T
Supply & fix in replacement steam globe valve 20 mm ISI Mark complete all as specified and directed by Engr-in-Charge. Make: Vaishno/L&T
Supply & fix in replacement steam valve 25 mm ISI Mark complete all as specified and directed by Engr-in-Charge. Make: Vaishno/L&T
Supply & fix in replacement High carbon steel V Belt pully four slot 18 inch dai including key suitable for washing Machine complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement High carbon steel V Belt pully three slot 09 inch dai including key suitable for washing Machine complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement solid cast iron machanical shaft 1.5 inch dia 1.5 mtr long complete all as specified and directed by Engr-in-Charge.
Over load relays MN 2 Directly Operated Type relays range 6 to 10 Amps complete all as specified and directed by Engr-in-Charge. Make: L&T/Autoix/MDS/SIMEMS or Equivalent.
Over load relays MN 5 Directly Operated Type relays range 9 to 15 Amps complete all as specified and directed by Engr-in-Charge. Make:L & T/Autoix/MDS/SIMEMS or Equivalent.
Over load relays MN 5 Directly Operated Type relays range 20 to 33 Amps complete all as specified and directed by Engr-in-Charge. Make: L & T/Autoix/MDS/SIMEMS or Equivalent.
Supply & fix in replacement drain solenoid coil complete all as specified and directed by Engr-in-Charge. Make: L&T/BCH/SIEMENS.
Supply & fix in replacement Steam solenoid Coil complete all as specified and directed by Engr-in-Charge. Make: Flocon or equivalent as approved by GE.
Supply & fix in replacement ball bearing UCF-P 207 with housing complete all as specified and directed by Engr-in-Charge. Make: NTN or Equivalent as approved by GE.
Supply & fix in replacement ball bearing UCF-P 209 with housing complete all as specified and directed by Engr-in-Charge. Make: NTN or Equivalent as approved by GE.
Supply & fix in replacement ball bearing UCF-P 213 with housing complete all as specified and directed by Engr-in-Charge. Make: NTN or Equivalent as approved by GE.
Supply & fix in replacement ball bearing UCF-P 215 with housing complete all as specified and directed by Engr-in-Charge. Make: NTN or Equivalent as approved by GE.
Supply & fix in replacement brake TDR (timer) suitable for Hydro Extractors/50 Kg complete all as specified and directed by Engr-in-Charge. Make: Vaishno/L&T.
Supply & fix in replacement cotton cloth padding with blanket for hand press table of size1.5 mtr x 1 mtr complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement Chain for washing machine/slucing machine/ drying tumbler/Hydro extractor complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement emergency stop switch complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement lubrication oil complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement steam valve 3 way complete all as specified and directed by Engr-in-Charge. Cat No SFP-30-052.
Supply & fix in replacement cotton padding with steel wool & Blanket suitable for flat Bed press complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement hand press heavy duty single phase 230 volt capacity 2000 KW Auto cut out complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement cotton cloth padding with steel wool and blanket suitable for flat work lroner single & double Rollers complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement Air flexible pipe (PVC) of size 15 mm dia complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement steam flexible pipe (PVC) of size 20 mm dia complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement Air flexible pipe for flat bed press complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement steam flexible pipe for flat bed press complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement MS Drain Assembly suitable for 100Kg/50 Kg / 25 Kg Washing machine (as per Sample) complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement Reversing Time Switch for Washing machine & Drying Tumbler (As per Sample) complete all as specified and directed by Engr-in-Charge. Make: Mukund or equivalent as approved by GE.
Supply & fix in replacement Alluminium casting Blower Fan For Drying Tumbler for 50 Kg & 25 Kg Washing manchine (As per sample) complete all as specified and directed by Engr-in-Charge.
S&F in replacement MS Drain pipe 4" dia 1.2 Mtr long with 4" MS Bend - 2 Nos & 2 flange sets & 6mm thick stainless steel drain pipe of size 75mmx75mm made to shape/design as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacment of electric driven motor 3 phase 1420/950 RPM, 2 HP and as per existing fittings complete all as specified and directed by Engr-in-Charge. Make: Crompton /Kirloskar/Jyoti/ Phillips as per existing make.
S&F in replacment of electric driven motor 3 phase 1420/950 RPM, 3 HP and as per existing fittings complete all as specified and directed by Engr-in-Charge. Make: Crompton /Kirloskar/Jyoti/ Phillips as per existing make.
Taking down old rusted iron sheet supply and fixing new iron sheet having thickness 1.25mm, cut to size and make to shape and fixing by welding and painting with two coats of synthetic enamel paint over one coat of red oxide to match with existing shade complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement water circulating reciprocating Water pump power sprayes including replancement of all defective parts and all other accessories in water circulating reciprocating pump complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement Pressure gauge 0 to 50 KG complete complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement for safety valve 25 mm complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement Electrode Assembly complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement for Hose Rubber complete all as specified and directed by Engr-in-Charge.
S&F Burner rod assembly complete all as specified and directed by Engr-in-Charge. Make: GEM/SEICD/ELITE/Marc.
S&F Connecting rod Assembly complete all as specified and directed by Engr-in-Charge.
S&F Optimizer complete all as specified and directed by Engr-in-Charge.
S&F Ball Valve 20mm BSPT complete all as specified and directed by Engr-in-Charge. Make: Prayag/BIR.
Supply and fix in replacement Gun Metal/Brass globe or Gate valve iron wheel head screwed both ends for iron pipes of size 50mm dia bore complete all as specified and directed by Engr-in-Charge.
All as per serial item No 191.00 here-in-before but for size 40mm dia pipe line.
All as per serial item No 191.00 here-in-before but for size 25mm dia pipe line.
All as per serial item No 191.00 here-in-before but for size 20mm dia pipe line.
Supply and fix in replacement Y Filter Stainer Gun Metal/Brass valve screwed both ends and dad plug for iron pipes of size 50mm dia bore complete all as specified and directed by Engr-in-Charge.
All as per serial item No 195.00 here-in-before but size 40mm dia.
S&F Non return valve 15mm dia complete all as specified and directed by Engr-in-Charge. Make: BIR/JAARC/Kirloskar.
Taking down Old / existing pipeline and Supply & fix new MS pipeline of 50mm bore covered with glass wool insulation and aluminium sheet 24 gauge thick packing / cover for glass wool fixed on wall with MS clamps / Side wall complete all as specified and directed by Engr-in-Charge.
All as per serial item No 198.00 here-in-before but 20mm bore.
Taking down Old / existing pipeline and Supply & fix MS pipe line of 15 mm dia for boiler, heavy duty including all fittings such as elbow, union, tee etc complete all as specified and directed by Engr-in-Charge.
All as per serial item No 200.00 here-in-before but of size 20mm bore.
All as per serial item No 200.00 here-in-before but of size 25mm bore.
Descaling chemical Maxclean 5 recommended by THARMAX (OEM of Steam Boiler) in 30/60 kg packing complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement in replacement of steam radiator with stainless steel tube and aluminum pulley suitable for dryer tumbler 50 kg and 25 kg (as per sample) complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement for replacement of defective filtters & resin of existing water softenning plant including all parts welding and allied work complete all as specified and directed by Engr-in-Charge.
Servicing of electrical control panel including replancement of all control wiring and repair to all relays and contactors, push buttons, indicators, LED display and all other accessories in control panel complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth wire 4 mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, CI cover made out of 5 mm CI Sheet with suitable handle and angle iron frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engr-in-Charge.
Supply & fix in replacement for earth continuity conductor or main earthing lead fixed to wall on batton or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to pole or any other indicated situation for loop earthing etc as required with 32x6mm galvanised iron strip complete all as specified and directed by Engr-in-Charge.
Dewatering the existing RCC O/H water storage tank for Laundry Plant and cleaning the internal wall and bottom surface of O/H Tank to remove silt / scales mud and other foreign materials using water and scrubbing with coir / jute / wire brushes and washing the surfaces with fresh water, cleaning the surfaces with mixture of bleaching powder and water and finally washing with fresh water and treating with one coat of white wash to internal walls bottom surface and ceiling of sump complete all as specified and directed by Engr-in-Charge.
Demolition of existing valve pit chamber , Supply & fix in replacement for masonry valve pit of size 900x900x900mm internal size complete with excavation, earth work and brick work in CM 1:6, 15mm thick plastering in CM 1:4 internally including 5mm thick MS Sheet cover and angle iron frame of suitable size and two coats of synthetic enamel paint over one coat of red oxide primer complete with locking arrangement complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement cast iron flanged drilled heavy duty sluice valve with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion nuts and bolts with washers of size 100 mm bore etc complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement 360 Degree rotating wheel for Dry line/wet line trolly, sutaible to bare 200kg weight complete all as specified and directed by Engr-in-Charge.
VARDHMAN INTERNATIONAL
M/S M P Construction Co
K S BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .