Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹42.2 Laccepted-aoc 89 SY NO SY NO 53 AND 54 20TH MAIN VIJAY NAGAR 2ND STAGE DEVARAJA MOHALLA MYSORE MYSORE KARNATAKA 570017 INDIA UDYAM KR 22 0020251 | MYSURU | KARNATAKA | 570017 | ₹42.2 L | accepted-aoc |
Tender Value
₹41.8 L
EMD Value
₹83,600
Closing Date
22 Apr 2026, 5:30 pmClosed
Karnataka Power Transmission Corporation Limited
Srinivas T
Augmentation of 2x8MVA, 66/11KV Power Transformers by 2 X 20 MVA, 66/11KV Power Transformers at 66/11KV Haradanahally Sub-station in Saligrama Taluk and Mysuru District on Partial Turnkey (PTK) basis including supply of all matching materials/equipment (except 66/11kV Power Transformer, NIFES and 11kV switchgear) and erection & including civil works of all materials/equipment, testing and commissioning.-Others-Call-3
KPTCL/2025-26/SS/WORK_INDENT3289
KPTCL/2025-26/SS/WORK_INDENT3289
Open
Sub-Station
Two Tender Document System(Two Cover)
KPTCL CEE Transmission Zone Office Mysuru
13 documents required · 13 mandatory
The Bidder should have carried out erection of atleast One(01) No. of 66kV voltage class or above voltage class Sub-Station/ Additional Transformer work OR atleast One(01) No. of 66kV voltage class or above voltage class Transformer Replacement/ Augmentation work on Total or Partial Turnkey Basis in the last 10 years preceding the date of bid submission and shall be completed and commissioned prior to the date of submission of the Bid OR The Bidder should have carried out erection of atleast Two (02) Nos of Agumentation/Replacement of 66kV or above voltage class Transformer works on Labour Contract Basis in the last 10 years preceding the date of bid submission and shall be completed and commissioned prior to the date of submission of the Bid OR Bidder who has executed Additional Transformer works or Replacement of Transformer works of private firms under the direct supervision of ESCOM/KPTCL officers are eligible to participate. Such Bidder should have carried out erection of not less than Two (02) Nos. of 66kV or above voltage class Additional Transformer Work on Total or Partial Turnkey Basis in the last 10 years preceding the date of bid submission and shall be completed and commissioned prior to the date of submission of the Bid
For other than proprietorship, the Bidder shall furnish the registered partnership deed and Power of Attorney
The Bidder shall be registered firm as Sole Proprietorship/Partnership/Pvt Ltd Company etc
Even though the Tenderers meet the above criteria, they are subject to be disqualified if they have:- Made misleading or false representations in the forms, statements and attachments submitted in proof of the qualification requirements and/or- Record of poor performance such as abandoning the works, not properly completing the contract, inordinate delays in completion, litigation history, or financial failures etc. and/or- Participated in the previous Tender for the same work and had quoted unreasonably high Tender prices and could not furnish rational justification.
Tenderers who meet the specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under:Assessed Available Tender Capacity: (AxNx2.5-B)Where A-Maximum value of works executed (KPTCL & Non-KPTCL) in any one year during the last five years (updated to FY 2024-2025) taking into account the completed as well as works in progress. N-Number of years prescribed for completion of the works for which tenders are invited.B-Value, at FY 2024-2025 price level of existing commitments (KPTCL & Non-KPTCL)and on-going works (KPTCL & Non-KPTCL) to be completed during the next 1(One)year.Note:(i)The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.(ii)A self-declaration is to be uploaded by the Tenderer stating that the information with regard to assessed available tender capacity (Works on Hand) furnished are correct.
valid Super grade Electrical Contractor License issued by the Government of Karnataka as on the date of opening of techno-commercial bid (refer 2.3 of ITT)
Minimum Average Annual Turnover (MAAT) of the bidder for best two(02) year out of preceding five financial years, shall not be less than Amount Put to Tender as per 3.2(a) of std tender documents(ITT).
Shall upload valid GST Certificate and PAN copy
EPF Certificate
ESI certificate
List of works for which tenders already submittedBidder shall ensure that soft copies of i. Letter of undertaking for Non performance ii. Letter of undertaking for Risk and Cost iii. Letter of undertaking for Litigation iv. Letter of undertaking to source the supply of equipment material from KPTCL approved Vendors only (if applicable) are uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date as per 3.10(xviii) of ITT
Bidder shall ensure that soft copies of Power of Attorney, Letter of Undertaking, No Deviation CERTIFICATE as revised in Annexure , Any other undertaking / agreement (if applicable) are to be uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date as per 3.10(xviii) of ITT
i. Letter of undertaking to source the equipment/material for the work from the approved Vendors who meet the eligibility clauses regarding restrictions on procurement from a country which shares a land border with India (Annexure-XVI) ii. Letter of undertaking as per clause No.1.5 of Annexure-XVII iii. Letter of undertaking as per clause No.1.6 of Annexure-XVII (if applicable) are uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date and on or before the date and time of opening of techno commercial bids.
₹1,050
₹83,600
5 Sept 2026
9 Apr 2026
24 Apr 2026
18 Apr 2026
Augmentation of 2x8MVA, 66/11KV Power Transformers by 2 X 20 MVA, 66/11KV Power Transformers at 66/11KV Haradanahally Sub-station in Saligrama Taluk and Mysuru District on Partial Turnkey (PTK) basis - CALL3
11kV isolators, Double Break 400A, 31.5 KA capacity with rigid b-metallic terminal connectors suitable for coyote ACSR for Outgoing feeders & Capacitor Bank
11kV isolators, Double Break 1200A, 31.5 KA capacity with rigid b-metallic terminal connectors suitable forDrake ACSR for Banks and Buscoupler
11 kV CTs 400-200/1-1-1A (for capacitor bank-1&2 for 500 MVA SWG) indoor/outdoor (oil filled type CTs).
11 kV CTs 1200-800/1-1-1A(for Incommer/Bus coupler for 500 MVA SWG) indoor/outdoor (oil filled type CTs).
11kV Class, 25kA, NCT of ratio 1200-800/1-1-1A for REFR Protection (of similar rating and ratio as that of Incomer of 11kV Switchgear) with terminal connector suitable for 2 Nos. of 75mmx6 mm Copper f...
11 kV NCT (0.157 t) station structure
11kV GOS/Cable Terminating structure for 11kV Capacitor bank (0.158 t per structure)
Post insulator clamp suitable for Twin Drake ACSR Conductor 127/76 mm 66 kV
Terminal connector clamps for Twin Drake ACSR Conductor 127/76 mm 66 kV suitable to 11kV Bank CT's & Breaker Limbs
Terminal connector clamps for Twin Drake ACSR Conductor suitable to 11kV Bushings of Power Transformer's.
C - Type Wedge Connector Double Drake to Single Drake for PT's 1
C-Type wedge connector (T-type) suitable for Coyote-Drake
C-Type wedge connector (T-type) suitable for Coyote- Coyote
Single Tension string of 90 KN. 1 units each along with hardware suitable for Coyote ACSR.
(11 kV)(Tension clamp+disc insulator+universal clamp)
PVC insulated Copper Control Cable with Lugs
19 Core 2.5 Sq.mm.
4 Core 6.0 Sq.mm.
4 Core 2.5 Sq.mm.
2 Core 2.5 Sq.mm.
Capacitor Bank:
Design, Engineering, supply, erection, testing & commissioning of 2.9 MVAR, 12.1 kV Capacitor Bank, star connected, Double Bank with internal fuses, terminal connectors with suitable ...
Multi Funtional Transducer (MFT)
Current Cables-Copper Core with c/s 4.0 sq.mm Multistrand 4 Core
Voltage Cables-Copper Core with c/s 2.5 sq.mm Multistrand 4 Core
Signal Cables-armoured Copper Core with c/s 0.5 sq.mm Multi strand 10 Core
Control Cables- Copper Core with c/s 1.5 sq.mm Multi strand 10 Core
Erection of 20MVA, -66/11kV TRANSFORMER.
Testing and commissioning of Transformer
11kV isolators, Double Break 400A, 31.5 KA capacity with rigid b-metallic terminal connectors suitable for coyote ACSR for Outgoing feeders & Capacitor Bank
11kV isolators, Double Break 1200A, 31.5 KA capacity with rigid b-metallic terminal connectors suitable forDrake ACSR for Banks and Buscoupler
11 kV CTs 400-200/1-1-1A (for capacitor bank-1&2 for 500 MVA SWG) indoor/outdoor (oil filled type CTs).
Testing and commissioning of CT
11 kV CTs 1200-800/1-1-1A(for Incommer/Bus coupler for 500 MVA SWG) indoor/outdoor (oil filled type CTs).
Testing and commissioning of CT
11kV Class, 25kA, NCT of ratio 1200-800/1-1-1A for REFR Protection (of similar rating and ratio as that of Incomer of 11kV Switchgear) with terminal connector suitable for 2 Nos. of 75mmx6 mm Copper f...
Testing and commissioning of NCT
Releasing & Re erection of existing HPI mounting structure (0.231MT/Structure)
11 kV NCT (0.157 t)
11kV GOS/Cable Terminating structure for 11kV Capacitor bank (0.158 t per structure)
Formation of Main/Cross Bus with Single coyote
Formation of Main/Cross Bus with double Drake
Laying of Copper control cable 19 Core 2.5 Sq.mm.
Laying of Copper control cable 4 Core 6.0 Sq.mm.
Laying of Copper control cable 4 Core 2.5 Sq.mm.
Laying of Copper control cable 2 Core 2.5 Sq.mm.
Multi Funtional Transducer (MFT)
Configuration of RTU and Engineering along with validation of data at SLDC
Current Cables-Copper Core with c/s 4.0 sq.mm Multistrand 4 Core
Voltage Cables-Copper Core with c/s 2.5 sq.mm Multistrand 4 Core
Signal Cables-armoured Copper Core with c/s 0.5 sq.mm Multi strand 10 Core
Control Cables- Copper Core with c/s 1.5 sq.mm Multi strand 10 Core
Integration of RTU, DCU and UPS with field equipment
Supplying and Grounding of Equipment with G.I.Flat 50x6mm and connecting Equipment to the earth mat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of ho...
Grounding of equipments by providing cast iron pipe of 100mm ID 13mm thickness, 2.75mtrs long with 2 part clamp out of G.I.Flat 50x6 mm continuously welded around the pipe using cast iron welding elec...
Supplying and fixing of 450mm diax 450mm height 1.5" to 2" hume pipe collars for earth pits.
Dismantling of 2X 8 MVA, 66/11KV Power Transformers and parts like Radiator, Bushings, Draining of oil from transformer etc., as per the direction of site Engineer (28+20.65=48.65MT)
Moving of Transformer from the plinth to the loading point as per direction of site Engineer.
28Mtx45mtrs x 1no.=1061
Moving of Transformer from the plinth to the loading point as per direction of site Engineer.
20.65 Mtx40mtrs x 1no.=826
Releasing of 800-400/1-1A NCT
Releasing of 11kV NCT Mounting Structure
Releasing of bank -1&2 CTs, And its Accessories
Releasing of capacitar bank -1&2 CTs, And its Accessories
Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per dr...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Structural Steel Fabrication:Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and app...
Removing and respreading of existing 20/25mm jelly.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Work on Hand details format.pdf
Others - workonhand • 0.17 MB
02 NIT-Mys Tz-Haradanhally C3.pdf
Instructions to Tenderers • 0.26 MB
Tender document kw2G-Haradanahally.pdf
Tender Document • 1.56 MB
credit facility certificate-FORMAT toUL.pdf
Others - credit facility format • 0.05 MB
Volume II A B.zip
Others - Volume II A B • 19.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .