Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 CrAccepted-AOC | ₹5.8 Cr | L1 | Accepted-AOC Amount after deduction of Schedule of credit. |
| 2 | L2₹6.2 Cr+₹33.9 L (5.79%)Rejected-Finance MIG 2B 83 H NO 65 5 466 GULLAPALEM SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹6.2 Cr+₹33.9 L (5.79%) | L2 | Rejected-Finance Other than lowest Bidder. The amount after deduction of Schedule of credit. |
| 3 | L2₹6.4 Cr+₹50.3 L (8.60%)Rejected-Finance MIG 1 12 GULLALAPALEM VUDA COLONY SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹6.4 Cr+₹50.3 L (8.60%) | L2 | Rejected-Finance Other than lowest Bidder. The amount after deduction of Schedule of credit. |
| 4 | L3₹6.3 Cr+₹44.7 L (7.64%)Rejected-Finance | ₹6.3 Cr+₹44.7 L (7.64%) | L3 | Rejected-Finance Other than lowest Bidder. The amount after deduction of Schedule of credit. |
| 5 | L5₹6.4 Cr+₹51.3 L (8.77%)Rejected-Finance D NO 55 41 18 1 DOCTOR S COLONY SEETHAMMADHARA VISAKHAPATNAM PIN 530013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | ₹6.4 Cr+₹51.3 L (8.77%) | L5 | Rejected-Finance Other than lowest Bidder. The amount after deduction of Schedule of credit. |
Tender Value
₹6.3 Cr
EMD Value
₹6.4 L
Closing Date
12 Jun 2020, 6:00 pmClosed
CE NAVY VISAKHAPATNAM
CE NAVY VISAKHAPATNAM STATION ROAD
PROVISION OF DEFICIENT IN-LIVING ACCN FOR OFFICERS AT INS RAJALI ARAKKONAM
2020_MES_316906_1
CE(NAVY)/VIZ/ARK/TOKEN/ 24 OF 2019-2020
Open Tender
Civil Works
Lump-sum
540 days
ARAKKONAM
AS PER NIT
9 documents required · 9 mandatory
₹3,000
GE M NAS ARAKKONAM
₹6.4 L
Yes
3 Jul 2020
22 Jan 2020
13 Jun 2020
22 Jan 2020
12 Jun 2020
5 Jun 2020
Amount
GENERAL SUMMARY NOTE: Schedule ‘A’ Part - I to XIV are prepriced by MES under Ser No. 2.00 to 15. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “BUILDINGS/STRUCTURES” as listed in Schedule ‘A’ Part - I , inserted by MES on serial page No. 35 R
Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY INCLUDING HOT WATER SUPPLY LINE” as listed in Schedule ‘A’ Part - II , inserted by MES on serial page No. 37 R
Lumpsum price worked out by the contractor for “INTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part - III, inserted by MES on serial page No. 40 R
Lumpsum price worked out by the tenderer for "EXCAVATION, EARTHWORK AND SITE CLEARANCE" as listed in Schedule ‘A’ Part-IV on serial page No. 42 R
Lumpsum price worked out by the tenderer for "ROAD / PATH / CULVERT / HARD STANDING" as listed in Schedule ‘A’ Part- V on serial page No. 46 R
Lumpsum price worked out by the tenderer for "AREA DRAINAGE" as listed in Schedule ‘A’ Part- VI on serial page No. 48 R
Lumpsum price worked out by the tenderer for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part- VII on serial page No. 50 R
Lumpsum price worked out by the tenderer for " FENCING / GATE" as listed in Schedule ‘A’ Part- VIII on serial page No. 53 R
Lumpsum price worked out by the tenderer for " RAIN WATER HARVESTING " as listed in Schedule ‘A’ Part- IX on serial page No. 55 R
Lumpsum price worked out by the tenderer for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part- X on serial page No. 57 R
Lumpsum price worked out by the tenderer for "EXTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part- XI on serial page No. 59 R
Lumpsum price worked out by the tenderer for "DEMOLITION AND DISMANTLING " as listed in Schedule ‘A’ Part- XII on serial page No. 60 R
Lumpsum price worked out by the tenderer for "ARBORICULTURE & WATER FOUNTAIN " as listed in Schedule ‘A’ Part- XIII on serial page No. 62 R
NOTE: Schedule ‘A’ Part - XIV (Miscelleneous) are not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
INTERNAL WATER SUPPLY Brass chromium plated wall mixer 3 way type (cold, Hot and mixer) with provision of overhead shower of dia not less than 200mm (3 mode operation) with 115mm long bend pipe on upper side connecting legs and wall flange for Bath room in officers accommodation complete all as specified and as directed.
INTERNAL ELECTRIFICATION Point wiring with 1.5 Sq mm (Nominal area) PVC insulated and unsheathed multi stranded copper conductor, 1100 volt FRLS grade single core cable for phase and neutral drawn through and including non metallic rigid PVC conduit medium grade minimum 20 mm size and its accessories and steel terminal boxs etc., complete concealed for incorparation of all types of modular fixtures, plates etc., like modular switchs, sockets, regulators, bell push and combination etc., including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity connected to earth dolly complete including fixing on modular cabinets/fixing on racks all as directed and specified for One light/bell point controlled by one switch
All as per Serial Item No 17 above but for One fan (ceiling/Wall/Ex fan) point controlled by one switch
All as per Serial Item No 17 above but for One 3 Pin socket outlet 5 amps socket on independent
All as per Serial Item No 17 above but for One 3 pin socket outlet 15 amps socket on independent board with 2.5 sqmm PVC insulated and unsheathed multi stranded copper conductor, 1100 volt FRLS grade single core cable and one run of 2.5 sqmm copper cable for earth continuty.
All as per Serial Item No 17 above but controlled by two two way switches complete all as specefied and directed.
Earth continuity conductor 4mm dia galvanised iron or steel wire or main earthing lead fixed to wall on batten or recess or chases or buired in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.as required complete all as specified and as directed.
Ceiling fan, 5 star rating suitable for working of AC 230V, 1200mm sweep with complete set with fixture,metallic body complete all as specified and directed.
MCB DB double door, single pole and neutral 08 way sheet steel phosphetised powder painted with 200 Amp rated bus bar 240 V natural link, IP 43 protection , double door flush mounting type, concealed in wall making good the distirubed surface etc complete all as specified and directed.
Exhaust fan, 200mm sweep or nearest size, plastic body (Heavy duty), complete with louvers suitable for opretion on to 230 V AC 50 Hz AC supply, fixed on wall making opening and making good the distirubed surface etc complete all as specified and directed.
Energy efficient 20 Watts LED security light fitting with new genration energy saving & environmental frindly long life versatile pressure die cast aluminium luminiare with mid power LEDs as source and HF electronic driver pre wired with 1.5 Sqmm copper conductor cable upto connector including 2 Mtr long GI Tubing Medium grade 32 mm dia bend to shape fixing on wall with suitable MS brackets complete all as specified.
Energy efficient LED ceiling light fitting 10 watt , integral round shape , 230V surface mounted with necessary diffuser complete with mounting bracket etc including conecting up with twin core twistwd flexible copper conductor cable with suitable size complete all as specified and as directed.
Energy efficiency LED mirror light fitting chrome colour ,metal & synthetic led 10 w 3000 k 500 with luminare 10 watt , 230 V surface mounted with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
Concealed vertical DB double door TPN 4 way 415 V 50Hz double door , IP 43 protection with 200 Amp rated Bus bar , including provision of incommer MCCB FP 63 Amp 10 KA and outgoing circuits complete , fill empty with blanks, concealing in walls, making good the distirubed surface etc complete all as specified and directed
Single phase tamper proof energy meter (KWH) upto 30 Amp, 230 V , digital display complete all as specified and as directed.
MCCB 4 pole 415 V 50 Hz 16 KA of capacity 63 Amp complete all as specified and as directed
Modular power unit 32 Amps with starter including Modular type socket outlet multipurpose 2/3 modules, including plug top and suitable combined cover plates with frames including flush metal GI box complete all as specified and directed.
MCB SP 240 volts 6 to 32 Amps, 10KA complete all as specified and as directed.
MCB SPN up to 32 Amps 240 V, 10 KA complete all as specified and as directed.
Concealed sub main wiring with 2 runs of Single Core 6 sqmm [ for phase & Neutral ] PVC insulated multi stranded FRLS copper cable drawn through PVC conduit of 20mm bore with accessories along with 1 run of single core 6 sqmm copper cable as earth continuity conductor complete all as specified and as directed. Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth along with PVC conduit will be measured as one length.
Concealed sub main wiring with 2 runs of Single Core 4 sqmm [ for phase & Neutral ] PVC insulated multi stranded FRLS copper cable drawn through PVC conduit of 20mm bore with accessories along with 1 run of single core 4 sqmm copper cable as earth continuity conductor complete all as specified and as directed. Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth along with PVC conduit will be measured as one length. ( for AC sub main wiring)
Earthing complete with galvanised steel earth plate electrode 600mm × 600mm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5, connected to earthing test point all as specified or indicated including excavation and connected earth work in hard /dense soil, PCC M-10, type C-1 as in pit chamber, 20 mm dia GI pipe medium grade for watering pipe,15 mm bore GI medium grade earth lead protection pipe connected upto DBs, and suitable C.I top cover with handle, funnel, strainer, salt, chorcoal and testing on completion all as specified and directed.
Note:(i) Quoted rate also deemed to include necessary excavation and earth work PCC M-10 chamber, RCC M-15 cover, renforcement removal of surplus soil , site clearance etc. (ii) GI earth wire 4 mm, GI tubing light grade 15 mm bore upto 7.5m from earth pit to building deemed to be included in the rate quoted by the contractor. (iii) Beyond 7.5 M the GI earth wire & GI pipe light grade 15 mm bore shall be measured under the respective item of the schedule.
EXTERNAL WATER SUPPLY Cutting existing CI pipe line 150mm bore near NORA Over Head Tank delivery line to insert 100mm dia Tee of size 150x150x 100mm including earth work etc.,
Pipe ductile iron Spigot and Socket including specials Class 'K-7' supplied and laid in trenches complete of size 100 mm (4 inch) dia
Gun metal Globe gate valves with iron wheel screwed both ends for iron pipes for 80mm dia complete all as specified and directed.
Brick masonary valve chamber of size 900 mm x 900mm x 900mm ( internal size) by providing PCC M-7.5, type D2 foundation 100 mm thick Flyash brick work in CM 1:4 plastering 15mm thick in CM 1:4 internal surfaces completely and external surfaces completely and external surfaces upto 150mm below GL, 75mm thick PCC M-15, type B1 as in coping valve chamber cover made up of 60x60x6mm thick angle iron frame and 6 mm thick MS sheet cover complete with locking arrangement and handle including painting steel surfaces with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including dismantling the existing damaged valve chamber and removing debris away from the premises etc,. complete all as shown on drawing No. TD 119 and as specified and directed
Brick masonary valve chamber of size 750mmx750mmx 750mm ( internal size) by providing PCC M-7.5, type D2 foundation 100 mm thick Flyash brick work in CM 1:4 plastering 15mm thick in CM 1:4 internal surfaces completely and external surfaces completely and external surfaces upto 150mm below GL, 75mm thick PCC M-15, type B1 as in coping valve chamber cover made up of 60x60x6mm thick angle iron frame and 6 mm thick MS sheet cover complete with locking arrangement and handle including painting steel surfaces with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including dismantling the existing damaged valve chamber and removing debris away from the premises etc,. complete all as shown on drawing No. TD 119 and as specified and directed
EXTERNAL ELECTRIC SUPPLY . Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate at a depth not less than 1.5m below ground level connected with and incl GI earth strip 32mm x 6mm including alternate 5 layers of charcoal and salt crystal and 40 mm dia GI pipe light grade by means of nuts bolts, washers and necessary excavation and earth work in any type of soil, PCC M-10, type C1 chamber and RCC M-15, type B-1cover and watering pipe 20mm dia medium grade with funnel complete with mesh , complete all as specified and as directed. Note:(i) Quoted rate also deemed to include necessary excavation and earth work PCC M-10 chamber, RCC M-15 cover, renforcement removal of surplus soil , site clearance etc. (ii) GI earth strip 32mm x 6 mm, GI tubing light grade 40 mm dia upto 7.5m from earth pit to building deemed to be included in the rate quoted by the contractor. (iii) Beyond 7.5 M the GI earth strip & GI pipe light grade 40 mm dia shall be measured under the respective item of the schedule.
Energy saving, street light fittings LED 40 watts luminaire with high power LEDs and unique flood optics to ensure uniform distribution and saving upto 50% w.r.t conventional system and maintenance free system, ideal for area lighting, high mast and bill board including fixing arrangement on pole by providing GI pipe medium grade 25 mm dia 1.5 Mtr in length with suitable size MS Clamp two Nos made out of 25x3 mm FI, prewired and including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to fitting all as specified and as directed by Engr-in-Charge.
Double compression copper gland for fixing armoured cable in panel suitable for the size of cable 185sqmm 3.5 core complete all as specified and as directed .
High efficiency wall mounted LED batten not less than 19 Watts with integrated electronic driver long with slim and sleek locks with all accessories internally prewired and including connecting up with 3 core twisted flexible copper conductor cable of suitable size from ceiling rose to fittings complete all as specified and as directed .
Double compression copper gland for fixing armoured cable in panel suitable for the size of cable 35 sqmm 3.5 core complete all as specified and as directed .
Double compression copper gland for fixing armoured cable in panel suitable for the size of cable 16sqmm 4 core complete all as specified and as directed .
Step down transfromer confirming to IS-1180-2014, 11 KV / 0.433 KV, energy efficient level 4, copper wound, outdoor type HT 11 KV 3 phase of capacity 160 KVA including both LT/HT side closed compartment 4 wire LT side, 50 cycles per second, oil immersed, naturally cooled connected with delta on HT side & star on LT side, LT side to vary secondary voltage +/- 7.5% in three steps of 2.5% of each with standard fittings / fixtures, cable box at HT / LT side with neutral brought out complete including first fill of transformer oil to appropriate level, temp gauge, breather tank, LT side cable box to be fitted with suitable size of cable gland, testing on completion and commissioning complete all as specified and as directed.
Powder coated Outdoor street light box of size not less than 280mm x 200mm x 100 mm CRCA sheet steel 3 mm thick IP 55, in and including suitable terminal TPN SMC Connector for three phase Cable Line ( IN & OUT), MCB 6 Amps SP 'C' Series, canopy weather proof hinged doors, locking system and arrangements for fixing on PCC / Steel Poles with suitable MS clamps as per site requirement including testing on completion complete all as specified and directed .
Common burnt clay building bricks, sub class 'B' of standard size for cable protection, laid dry complete all as specified and directed.
HT adopter box made out of CRCA sheet steel, powder coated 3mm thick with fixing arrangement, consisting of extension of existing HT bus bars with suitable size of copper bus bar with all jointing materials, insulators etc., for taping from existing RMU / HT VCB panel to the proposed out door type VCB panel complete all as specified and as directed .
Open well submersible pump set of capacity 1.5 HP, single phase 230 Volts, 50 HZ SS body and SS shaft including supply and fixing DOL starter panel out door type and two core copper conductor un armoured cables for submersible pumps of required length from starter panel to pump including testing on completion all as specified and as directed.
SOLAR WATER HEATER 300 LPD Solar water heating system at 600 C (average) temperature with exchanger and electrical heating backup comprising of following main accessories, testing on completion and commissioning complete all as per manufacturers instructions and as directed. (a) Flat plate collector (as per BIS 12933) - 01 No. (b) Stand for collectors - 01 No. (c) Stainless steel hot water tank (SS - 304) TIG welded with PUF insulation &Stainless steel outer cladding - 01 No. (d) Stand for hotwater tank - 01 No. (e) Air vent - 01 No. (f) 15 Amps power point with copper wiring as required.
200 LPD Solar water heating system at 600 C (average) temperature with exchanger and electrical heating backup comprising of following main accessories, testing on completion and commisioning complete all as per manufacturers instructions and as directed. (a) Flat plate collector (as per BIS 12933) - 01 No. (b) Stand for collectors - 01 No. (c) Stainless steel hot water tank (SS - 304) TIG welded with PUF insulation &Stainless steel outer cladding - 01 No. (d) Stand for hotwater tank - 01 No. (e) Air vent - 01 No. (f) 15 Amps power point with copper wiring as required. Note for Item No. 58 and 59: The quoted rate shall be deemed to be inclusive of PCC bed for stand for collectors, stand for hot water tank, connecting civil and other miscellaneous works and all accessories as per manufacturers instructions to make the system functional to achieve the required out put parameters.
Rotational moulded polyethylene water storage tank 3 layer, 500 ltrs capacity, (cylindrical vertical with closed top) hoisted and fixed in position at a height as directed by OEM of solar water heater with connecting civil works i.e., 25mm bore PTMT ball valves high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipes with polythene float and fly nut, including connecting up with solar water heater system complete all as specified and directed. Note for Item No. 60: The quoted rate shall be deemed to be inclusive of PCC bed, platform with Fly ash brick masonry in CM 1:4, 10mm thick plastering in CM 1:4 finished even and smooth and two coats of weather proof exterior emulsion paint over one coat of primer and RCC M 30 platform for resting water tank of required size at required height including reinforcement etc,, complete all as specified and as directed.
WATER COOLER:- Water cooler partially stainless steel body, electric driven, single phase,having approximate storage capacity of 80 ltrs and normal cooling capacity of 40 Ltrs/hour and commissioning at location as shown on drawing complete all as specified and directed.
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and as directed.
ARBORICULTURE & WATER FOUNTAIN Filling fertile soil brought from out side MD land for growing green plants etc complete all as specified and as directed.
Green korean grass for ready fixing in gradens including watering upto growing for a period of 3 months complete all as specified and as directed.
Excavating in any type of soil upto 450 mm wide and not exceeding 450 mm depth and removing upto a distance not exceeding 50mt filling back with red earth of 15cm thick mixed with farm yard manure/vermi compost in the raio (3:1) with necessary pesticide treatment breaking the clads with wooden sludges 15cm thick, planting and developing of hedging and edging plants/shrubs with height of 30cm and above, 30cm apart such as Golden Duranta/Acalifa etc as approved by GE and maintaining for six months by regular watering weeding with skilled labours etc complete all as specified and as directed by Engineer-in-charge . Note for Item No. 64 and 65:- Rate quoted shall include for two years maintenance from the certifiied date of completion including necessary watering and necessary compost/manure required for fertilisation and healthy qrowth of plant during maintenance period.
Brass water spinklers including all necessary fitings and fixtures for watering on grass complete all as specified
SRI SURYA PROJECTS
C R R CONSTRUCTIONS
S A R CONSTRUCTIONS
PMR CONSTRUCTIONS
CIVILEC ENGINEERING WORKS
VIJAY VINAYAKA INFRA
SOUTHERN BUILDERS
M/s.DSRK CONSTRUCTIONS
VEYEM ENGINEERING SERVICES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .