Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC 0001 000 KACHARI ROAD RAMAIPATTI MIRZAPUR UTTAR PRADESH 231001 | MIRZAPUR | UTTAR PRADESH | 231001 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹31.6 L+₹24,507.95 (0.78%)Rejected-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹35.0 L+₹3.6 L (11.4%)Rejected-AOC | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹36.5 L+₹5.1 L (16.3%)Rejected-AOC N A | NA | NA | 121004 | L4 | Rejected-AOC Not L1 Bidder | |
| 5 | L5₹37.6 L+₹6.2 L (19.7%)Rejected-AOC M 78 GARU HARKISHAN NAGAR PASCHIM VIHAR NEW DELHI 110087 | NEW DELHI | WEST DELHI | DELHI | 110087 | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Jul 2024, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
REPAIR MAINTENANCE OF SUBMERSIBLE MONOBLOCK AND CENTRIFUGAL PUMP SETS AND ELECTRIC CONTROL PANELS INCLUDING DEVELOPMENT OF BOREWELLS AND CONNECTED ITEMS OF WATER SUPPLY INSTALLATIONS OF COD AREA AND NODAL POINT II AREA OF AGE WATER SUPPLY NO I UNDER
2024_MES_658112_1
GE/WS/Token-02 OF 2024-25
Open Tender
Civil Works
Item Rate
330 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹96,000
Yes
3 Sept 2024
6 Jun 2024
6 Jul 2024
6 Jun 2024
4 Jul 2024
20 Jun 2024
Amount
Disconnecting electric connections from LT control panel and starter of submersible pump set of size 2 to 15 HP and removing the pipe line connections from discharge side and taking down/out submersible pump set along with column pipe from bore well with the help of chain pully block including transportation to workshop for repairs and back and lowering of same pump in bore well after repairs after replacement of rusted nuts, bolts, washers, rubber gasket etc including testing & commissioning complete all as specified and directed (Note : Serviceability of pumpset after repair shall be got tested by EIC before re-installation and lowering. Each pump maintenance/functionality/serviceability will be covered for one year after satisfactory repair and if pump motor winding brunt out in the contract period or within defect liability period of one year, the same will carried out by contractor Free of cost at his own arrangement. A BOO will be ordered for checking of serviceability & functionality of pump after repair from work shop and the same will be kept on record dully signed & concurred by GE. These aspect will be considered during quoting rates per unit (Each Job)
Disconnecting electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric motor of any capacity and makes from base plate of pump set after opening the nuts, bolts etc and Dismantling of the induction/Submersible motor and seperate the stator and rotor and removing the Unserviceable DE & NDE side bearing, burnt winding wire from stator and rewinding the same as per existing supper enamelled copper wire gauge with 'F' class insulation used including varnishing and heating for drying of winding, transporting the motor to workshop for repair and back, re-installed after repair including testing complete all as specified and directed (Note : (i) Bidder will quote all in all rate according to weight of copper rewinding retrieved after dismentling and mode of measurement of the item is in "KG" only for all the repair/over hauling. Please quote rate accordingly, no any extra cost will be paid by Govt. (ii) A BOO conveyed for working out old unserviceable copper winding quantity details of each pump and the same replaced with new super enamel copper wire of suitable gauze as per old pumps make and submit report of serviceability / functionality of pumps.
(iii) Transportation/freight charges for shifting of pump to workshop and recieved back in the laying/installation place as directed by Engineer-in-Charge shall be deemed included in quoted rate. (iv) Old unserviceable brunt copper winding wire shall be contractor's property and accodingly unit rate by contractor shall be treated as included od unserviceable copper winding recieved by him during repair/over hauling.
Disconnecting electric connection and De-coupling the Centrifugal pump and removing from foundation for repair after opening /cutting the rusted nuts, bolts etc and dismantling complete pump and repairing the same with replacing the following unserviceable spare parts i.e. CI Casing wear ring, interstage ring, stuffing box bush, lentern ring, eye bolt with nut, shaft sleeve, impeller key, coupling key, water liquid reflector, bearing cartridge, bearing plate, shaft bush, MS stud with nut, mechanical seal, gasket packing including grinding work of lathe machine if any and re-assembling the same including the transporting the pump from side to workshop for repair and back, re-installed at existing position after repair and providing new MS nuts, bolts, packing flange etc including testing complete all as specified and directed of following capacity:-
5 to 12.50 HP Capacity centrifugal pump
20 to 25 HP Capacity Centrifugal pump
30 HP Capacity Centrifugal pump
40 HP Capacity Centrifugal pump
75 to 105 HP Capacity Centrifugal pump
(Note:- (i) Proper inventory for repair and over hauling parts replaced during the repair in work shop shall be prepared and kept in record dully verified and signed by EIC. (ii) Old unserviceable parts repaired & replaced shall be taken on charge under demolition/salvage register with page number in demolition statement.)
Disconnecting the electric connection of monoblock pump of capacity 7.5 to 10 HP and removing the same from foundationfor repair after opening /cutting the rusted nuts, bolts etc and dismantling complete pump and repairing the same with replacing the following unserviceable spare parts i.e CI Impeller, GM shaft sleeve, Mechanical seal, water seal, water liquid reflector, MS stud with nut, gasket packing including grinding work of lathe machine and re-assembling the same including the transporting the pump from side to workshop for repair and back, re-installed at existing position after repair and providing new MS nuts, bolts,packing flange etc including testing complete all as specified and directed. (Note:- (i) Proper inventory for repair and over hauling parts replaced during the repair in work shop shall be prepared and kept in record dully verified and signed by EIC. (ii) Old unserviceable parts repaired & replaced shall be taken on charge under demolition/salvage register with page number in demolition statement.)
Dismantling complete submersible pump and repairing the same with replacing the following unserviceable spare parts i.e GM bush, rotor sleeve, water seal,cable seal, thrust bearing, sealing ring, upper & lower housing flange upper & lower with stud and nut, wire mesh, drain plug, SS distance sleeve, impeller key, inter ring GM neck ring, Guide bush, GM impeller/EPV Impeller, CI section chamber,SS coupling, CI stage bowl, T bolt with nut including grinding work of lathe machine and re-assembling the same testing, complete all as specified and directed of following capacity:- (Note:- (i) Proper inventory for repair and over hauling parts replaced during the repair in work shop shall be prepared and kept in record dully verified and signed by EIC. (ii) Old unserviceable parts repaired & replaced shall be taken on charge under demolition/salvage register with page number in demolition statement.
5 to 7.5 HP Submersible pump
Submersible pump of capacity 10 to 12.5 HP
Disconnecting the all electric connection and lifting the raw sewage pump set from sludge well/equilisatin tank and dismantling complete raw sewage submersible pump of capacity 5 to 7.5 HP and repairing the same with replacing the following unserviceable spare parts i.e GM bush, rotar sleeve, water seal, thrust bearing, sealing ring, upper & lower housing flange upper & lower with stud and nut, wire mesh, drain plug, SS distance sleeve, impeller key, inter ring GM neck ring, Guide bush, GM impeller, CI section chamber,SS coupling, EPV impeller, CI stage bowl, T bolt with nut including grinding work of lathe machine and re-assembling the same testing complete all as specified and directed. (Note:- (i) Proper inventory for repair and over hauling parts replaced during the repair in work shop shall be prepared and kept in record dully verified and signed by EIC. (ii) Old unserviceable parts repaired & replaced shall be taken on charge under demolition/salvage register with page number in demolition statement.)
M&L for pump shaft stainless steel suitable for centrifugal pump set up to 15 HP including turning, grinding and balancing work in work shop complete all as specified and directed by EIC.
M&L for pump shaft stainless steel suitable for centrifugal pump set up to 40 HP including turning, grinding and balancing work in work shop complete all as specified and directed by EIC.
M&L for pump shaft stainless steel suitable for centrifugal pump set up to 105 HP including turning, grinding and balancing work in work shop complete all as specified and directed by EIC. (Note for ser item No 7 to 9:- Old U/s material shaft obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
M&L for CI Impeller suitable for centrifugal pump set up to 15 HP including turning, grinding and balancing work in work shop complete all as specified and directed by EIC.
M&L for CI Impeller suitable for centrifugal pump set up to 40 HP including turning, grinding and balancing work in work shop complete all as specified and directed by EIC.
M&L for CI Impeller suitable for centrifugal pump set up to 105 HP including turning, grinding and balancing work in work shop complete all as specified and directed by EIC. (Note for ser Item No 10 to 12:- Old U/s material CI Impeller obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
M&L for taking up the suction pipe of size 80/100/150 mm dia after opening of Nuts and Bolts and open the bottom plate of Swing type CI Valve and replace the unserviceable leather Gasket of swing disc as per existing size but of minimum thickness not less than 6 mm complete all as specified and directed.
Supply and fixing in replacement GI Nipple with flange welded, heavy duty 50 x 300 mm size complete all as specified and as directed.
All as per serial item No 14.00 here-in-before but of size 80 x 300 mm (Note for ser Item No 14 to 15:- Old U/s material GI Nipple obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply only in replacement of GI column pipe, heavy grade, class 'C', 50 mm bore of 3 metre length, heavy duty, flange welded on both ends complete all as specified and directed.
Supply only in replacement of GI column pipe, heavy grade, class 'C', 80 mm bore of 3 metre length, heavy duty, flange welded on both ends complete all as specified and as directed. (Note for item No 15 & 16: Old U/s material GI Column pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in length (RM) shall be taken into account and attach with RAR/F Bill)
S&F in replacement of submersible copper cable of size 2.5 Sqmm 3 Core. 1100 Volt complete all as specified and directed
All as per serial item No 18.00 here-in-before but cable of size 4 Sq mm 3 core, 1100 Volts . (Note for Ser Item no 18to 19 :- Old U/s cable obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in length (RM) shall be taken into account and attach with RAR/F Bill)
M&L Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 volts LT cables of different sizes from both ends , removal of fault , reconnection and testing of cables after removal of fault complete all as specified and directed. NOTE:- (a) 1100 volt cables and joints shall be measured and paid for seperately under respective items of schedule (b) Retrieved old serviceable cable cover/ bricks will be laid in trenches for cable protection. If extra PCC cover / bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Exacavation and earth work will be measured and paid for separately under respective items of schedule.
Supply and fixing, testing & commissioning in replacement heat shrinkable jointkit suitable for XLPE cable insulated screened PVC bedded armoured electric power cable heave duty 1100 volts grade, with straded aluminium conductor, cross sectional area 25 to 35 Sqmm, 3.5 core after taking down/out faulty portion as exists compete all as specified and directed. (Note:- Old unserviceable Joint material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
M & L for preparation of surfaces for painting of existing submersible pump sets of capacity 2 to 15 HP and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
Supply and fixing in replacement of Mild steel clamps in Mild steel flat of size 50mm x 6 mm with including two Nos Mild steel nut and bolts suitable for 50mm bore column pipe complete all as specified and directed.
Supply and fixing in replacement of Mild steel clamps in Mild steel flat of size 80 mm x 6 mm with including two Nos Mild steel nut and bolts suitable for 80mm bore column pipe complete all as specified and directed. (Note for ser Item No 22 to 23:- Old U/s material clamps obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supplying and Fixing in replacement of Terminal Connection Plate of following capacity:- (Note:- Old U/s material Terminal connection plate obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and fixing spare tyre for coupling type TC/P/011 after taking down/out as existing at site complete all as specified and directed
Supply and fixing spare tyre for coupling type TC/P/013 after taking down/out as existing at site complete all as specified and directed
Supply and fixing spare tyre for coupling type TC/P/014 after taking down/out as existing at site complete all as specified and directed
Supply and fixing spare tyre for coupling type TC/P/015 after taking down/out as existing at site complete all as specified and directed.
Supply and fixing spare tyre for coupling type TC/P/017/019 after taking down/out as existing at site complete all as specified and directed. (Note for ser item No 26 to 30:- Old unserviceable material spare tyre shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply and Fixing in replacement of Ball Bearing 6305 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6306 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6307 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6308 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6309 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6310 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6311 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6312 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Ball Bearing 6314/6316 as per existing complete all as specified and directed.
Supply and Fixing in replacement of Roller Bearing NU-314/316 as per existing complete all as specified and directed. (Note for ser item No 31 to 40:- Old unserviceable material ball bearing shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
M&L applying two coat of synthetic enamel paint as per existing pattern or scheme, on centrifugal pump & motor of any capacity rating 5-120 HP and suction/ delivery pipeline including NRV and sluice valve, MS Base channel after removing of existing paint including preparation of surfaces by scratching and removing the rust complete all as specified and as directed.
Supply,Laying, jointing, Testing and commisioning of MS Pipe in replacement of following size, as per IS:1239 with and including MS flange, 16 mm thick welded for drilling of 16 mm dia bolts, nuts, washers, rubber gaskets etc laid in trenches complete all as specified and directed:-
(Note for Ser item No 42:- Old U/s MS Pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in length (RM) shall be taken into account and attach with RAR/F Bill)
Supply & Fixing in replacement MS Flange of following sizes, 16 mm thick, duly welded on ends of MS pipe including necessary cutting to existing MS pipe or in new MS pipe with flange joint including nuts, bolts, washers and rubber gaskets complete all as specified and as directed:- (Note:- Old unserviceable MS Flange shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply and Fixing in replacement of Vibration Pad with nuts, bolts and washers, for existing capacity of 40 HPcomplete all as specified and as directed.
Supply and Fixing in replacement of Vibration Pad with nuts, bolts and washers, for existing capacity of 40 HPcomplete all as specified and as directed. (Note for ser item No 44 & 45:- Old U/s material Nut & bolts obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supplying and laying, testing & commissioning of LT XLPE insulated, armoured heavu duty electric cable with aluminium conductor 1100 Volts grade cross sectional area 25 Sqmm 4 Core laid in trenches/floor/wall incl taking out old unserviceable cable and connection to panel for incoming and outgoing using suitable aluminium lugs complete all as specified.
Supplying and laying, testing & commissioning of LT XLPE insulated, armoured heavu duty electric cable with aluminium conductor 1100 Volts grade cross sectional area 35 Sqmm 4 Core laid in trenches/floor/wall incl taking out old unserviceable cable and connection to panel for incoming and outgoing using suitable aluminium lugs complete all as specified. (Note For Ser Item No 46 & 47:- (i) Excavation & earth work will be measured and paid seperately under respective items. (ii) Old U/s LT XLPE aluminium cable shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in length (RM) shall be taken into account and attach with RAR/F Bill). (iii) Layout of LT XLPE cable shall be approved by ACcepting Officer before commencement & laying of cable. (iv) Route marked indicator will be provided by contractor and quoted rate deemed included such aspects.
Openning of gland packing coupling and removing the unserviceable gland rope from centrifugal/Monoblock pump set of capacity 5 to 40 HP and fixing the new gland rope all as per existing size gland rope complete all as specified and directed.
Openning of gland packing coupling and removing the unserviceable gland rope from centrifugal/Monoblock pump set of capacity 75 to 105 HP and fixing the new gland rope all as per existing size gland rope complete all as specified and directed.
Openning of gland packing coupling and removing the unserviceable gland rope from Sluice valve of size 100 to 300 mm dia and fixing the new gland rope all as per existing size gland rope complete all as specified and directed. (Note for Ser item No 48 to 50:- Old U/s gland plate obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified ans directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified and directed.
Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified and directed.
Supply, fillings & spreading of fine 'Yamuna River' sand in trenches by providing 15cm below cable punned to 10cm after hand roller and 8cm above cable for cable protection complete all as specified ans as directed. NOTE: Punned down thickness of sand shall only be taken for measurement & payment.
M&L for laying kiln burnt brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm width of brick equal to length of trench across the cable complete all as specified and as directed
S&F including testing & commissioning of Decorative ultra slim round profile LED lightning fixture 20W, 6000K, with extruded polycarbonate environmental friendly energy efficient incl taking down old unsv light fitting complete all as specified and as directed. (Note:- Old unserviceable light fittings shall be contractor's property and quoted rate shall be deemed inlcuded cost of old unserviceable fittings.)
Supply and fixing including testing & comiisioning in replacement 60 watt LED street light New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 including making connections with GI pipe 0.6mtr angle braket fixing on wall and connectng to ceiling rose with apropriate wire complete all as specified and directed. (Note:- Old unserviceable light fittings shall be contractor's property and quoted rate shall be deemed inlcuded cost of old unserviceable fittings.)
Supply and fixing in replacement of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 08 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified.
M&L for MCB SPN 40 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series including taking down old unsv MCB complete all as specified and as directed
M&L for MCB SP 6-32 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series including taking down old unsv MCB complete all as specified and as directed.
Supply and fixing in replacement ceilling fan 1200 mm sweep Single pole 230V , 50Hz 'Five Star' complete with five step electronic fan regulator and down rod connection complete all as specified and directed. (Note for Ser Item No 61:- Old unserviceable ceiling fan shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply and Fixing in replacement MS base channel of size as exists including cutting, welding and making hole, applying two coats of synthetic enamel paint over a coat of red oxide primer including dismounting existing Centrifugal pump motor set and taking out old unservicable existing MS Base chennel complete all as specified and as directed. (Note:- Old U/s material MS frame obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply and Fixing in replacement of MS foundation bolts with nuts and washers, size 20mm dia, 450 mm long complete all as specified and as directed.(including breaking of hard standing foundation) (Note:- Old unserviceable bolts shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Supply and fixing rotational moulded polyethylene water storage tank , cylindrical vertical with closed top, 500 ltrs capacity, triple layered hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified an as directed. Note: Old unserviceable PVC tank shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
M&L for development of bore well of any capacity and size at the pressure 10 kg/sqcm to 15 kg/sqcm by diesel engine driven air compressor of capacity 620 cfm includiing air pipe and connected items to improve the yield of tube well complete all as specified and directed by Engineer in charge.
M&L for development of bore well of any capacity and size at the pressure 22 kg/sqcm to 25 kg/sqcm by DTH Machine of capacity 1200 CFM including air pipe and connected items to improve the yield of tubewell complete all as specified and directed by Engineer in charge. (Note for Ser item No 65 & 66: The rate deemed to include the cost of Transportation of machine and minimum 1 Hrs of running.)
M&L Brick work with sub class 'B' old size bricks bricks straight or cured on plan exceeding 6 m mean radius built in cement mortar 1:6 including demolition of old U/S brick work complete .
M & L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement including demolition and dismantling concrete complete all as specified and as directed
Hacking out old broken glass any thickness, size, quality or description from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads including S&F 3 mm thick plain sheet glass ordinary quality in square not exceeding 0.5 sqm area of pane complete all as specified and directed.
Supply and fixing & installation in replacement of perforated MS cable tray of size 350x50x2mm including horizontal and vertical bends, prepared hanging system and other accessories including painting of cable tray of complete all as specified.
M&L for fabrication (welding work ) of MS Header/ any size upto 300mm MS pipe at various pump house site for connection of pipe , arresting leakges on header complete all as specified and directed.
M&L pre moulded machine pressed precast concrete interlocking paverblocks any shape and size confirming to IS 15658-2006 of 60 mm thick, M-35 Grade with grey cement and no pigments top 10mm layer of paver block shall be of rubber moulded type coloured pigment mixed with marble chips layer laid over 40 mm thick sand cushioning complete all as specified and as directed. (Note : (i) Sand Cushioning shall be measured and paid under respective item. (ii) Old U/S paver block shall be kept in charge under demolition ledger and will be reused if found satisfactory in low lying area as directed by EIC.
Supply & fixing , install testing and commissioning of feeder pillar box in replacement outdoor type cubical shape, three phase, 4 wire, Aluminium bus bar for phases and neutral made out of CRCA sheet 3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar, switch gear & danger Notice plate of size 300x200mmx3mm thick marked skull & bones with highlightend flourescent glow paint etc all as specified and comprising of following including necessary cable connections to the MCCBs, voltmeter, Ammeter and cable lugs etc & dismantling of old unserviceable LT panel with all accessories in any conidtion from foundation for shifting to MES store yard:-
(i) Aluminium bus bar with PVC sleeve suitable for 400 amps for phase & 300 Amp for neutral - 01Set.
(iv) Phase indicating lamps LED type ( red , yellow, blue) 01 set
(v) Incoming MCCB 250 Amp 4 pole 36 KA with adjustable thermal and fixed magnetic release -01 No
(vi) Outgoing MCCB 160 Amp 4-Pole 36 KA with adjustable thermal and fixed magnetic release - 02 No
(vii) ML-3 Star Delta starter fully automatic suitable for 415V AC upto motor 40 HP with ON/OFF & Trip indication including sheet enclosure.-02 Nos
Supplying, fixing, testing and commissioning of feeder pillar box in replacement indoor type cubical shape, 3 Phase, 4 Wire, Aluminium bus bar of 200 Amps with PVC sleeve suitable for phases and neutral, made out of CRCA sheet 2.0 mm thick, factory fabricated ,CPRI approved, powder coated ,dust and vermin proof, with provn for ventilation, angle iron frame and four legs of 50x50x6mm thick angle iron, 2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level, grouting properly and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar, switch gear & danger Notice plate of size 300x200mmx3mm thick marked skull & bones with highlightend flourescent glow paint etc all as specified and comprising of following including necessary cable connections to the MCCBs, voltmeter, Ammeter and cable lugs etc & dismantling of old unserviceable LT panel with all accessories in any conidtion from foundation for shifting to MES store yard:-
Aluminium bus bar with PVC sleeve suitable for 300 amps for phase & 200 Amp for neutral - 01Set.
Phase indicating lamps LED type ( red , yellow, blue) 01 set
Incoming:- MCCB 160 Amp 4 pole 36 KA with adjustable thermal and fixed magnetic release -01 No
Outgoing:- MCCB 100 Amps, 3 pole 18 KA with adjustable thermal and fixed magnetic release -02 No
ML-2 Star Delta starter fully automatic suitable for 415V AC upto motor 15 HP with ON/OFF & Trip indication including sheet enclosure-02 Nos
(Note for Ser item No 73 & 74:- (i) Panel drawing shall be approved by Accepting Officer. (ii) Old unserviceable LT panel alongwith all accessories in any condition shall shifted to MES store yard and it will be taken on charge under demolition/salvage register. (iii) Make of accessories will be as per CA scpefication list of make & manufacturer's. (iv) The rate quoted deemed included all wiring & connection and testing installation & comissioning work.
M&L for replacement to Off load Change over Switch of rating 100 Amp, 4-Pole 415V as per IS / IEC: 60947 - 1&3 with dual mounting facility fixed at exisiting/new location incl the connections complete all as specified and directed by Engr-in-Charge.
M&L for replacement to Off load Change over Switch of rating 200 Amp, 4-Pole 415V as per IS / IEC: 60947 - 1&3 with dual mounting facility fixed at exisiting/new location incl the connections complete all as specified and directed by Engr-in-Charge.
M&L for replacement to Off load Change over Switch of rating 325 Amp, 4-Pole 415V as per IS / IEC: 60947 - 1&3 with dual mounting facility fixed at exisiting/new location incl the connections complete all as specified and directed by Engr-in-Charge.
M&L for replacement to Off load Change over Switch of rating 400 Amp, 4-Pole 415V as per IS / IEC: 60947 - 1&3 with dual mounting facility fixed at exisiting/new location incl the connections complete all as specified and directed by Engr-in-Charge.
M&L for replacement to Off load Change over Switch of rating 630 Amp, 4-Pole 415V as per IS / IEC: 60947 - 1&3 with dual mounting facility fixed at exisiting/new location incl the connections complete all as specified and directed by Engr-in-Charge. (Note for ser item No 75 to 79:- Old U/s change over switch & time switch obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in length (EACH) shall be taken into account and attach with RAR/F Bill)
Supply and fixing in replacement PVC insulated multistranded copper conductor wire of 10 Sqmm size, single core, 1100 volts complete all as specified and as directed.
Supply and fixing in replacement PVC insulated multistranded copper conductor wire of 16 Sqmm size, single core, 1100 volts complete all as specified and as directed.
Supply and fixing in replacement PVC insulated multistranded copper conductor wire of 25 Sqmm size, single core, 1100 volts complete all as specified and as directed.
Supply and fixing in replacement PVC insulated multistranded copper conductor wire of 35 Sqmm size, single core, 1100 volts complete all as specified and as directed. (Note for ser item No 80 to 83:- Old U/s cable obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in (RM) shall be taken into account and attach with RAR/F Bill)
Supply, laying jointing, testing & rerouting in replacement of 80mm MS pipe class 'C' as per IS:1239 including MS flange 16 mm thick both side welded and nuts, bolts, washers, rubber gaskets etc complete for laid in trenches/floor complete all as specified and as directed by Engineer-in-Charge. (Note :- Old U/s MS Pipe obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in (RM) shall be taken into account and attach with RAR/F Bill)
S&F Fully automatic stat delta motor starter of maximum motor output 17.5 Hp of motor rating AC 3 duty 415V 50 Hz 3 phase, MN-16, relay range 9-15 Amps including taking down old starter complte complete all as specified and as directed by Engr in charge
S&F Fully automatic stat delta motor starter of maximum motor output 30 Hp of motor rating AC 3 duty 415V 50 Hz 3 phase, MN-25, relay range 14-23 Amps including taking down old starter complte complete all as specified and as directed by Engr in charge. (Note for ser item No 85 & 86:- Old U/s stat delta starter obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in (EACH) shall be taken into account and attach with RAR/F Bill)
Supply and fixing in replacement of Recessed Mounted with PLUTO Neo PANEL 2X2 LED 42 Watt Environmental friendly, new generation,aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling complete all as specified and direcred
S & F in replacement of 25 Watt LED post top New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source connection complete all as specified and direcred. (Note for ser item No 87 to 88:- Old U/s light fitting obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in (EACH) shall be taken into account and attach with RAR/F Bill)
Material and labour for painting two coat of synthetic enamel paint as per existing pattern on pipe surface/header connection including preparation of surfaces by scratching and removing the rust, red primer coat complete all as specified and as directed
Supply and fixing in replacement of 3 pole power contactor 300 Amp 415/440 volts 50 HZ type ML-12 2 NO+2NC complete all as specified and as directed
Supply and fixing in replacement of 3 pole power contactor 110 Amp 415/440 volts 50 HZ type ML-6 2 NO+2NC complete all as specified and as directed. (Note for ser item No 90 to 91:- Old U/s contactor obtained from demolition shall be taken on charge in demolition/ salvage register and enter page number in demolition statement. Necessary RV in (EACH) shall be taken into account and attach with RAR/F Bill)
M P TYAGI ENGINEERS AND CONTRACTORS
B.R. Enterprises
M/s Sree Baba Traders
SALUJA CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .