Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹13.7 L+₹1.4 L (11.2%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹13.8 L+₹1.5 L (12.2%)Rejected-Finance | L3 | Rejected-Finance Not being lowest |
Tender Value
₹14.7 L
EMD Value
₹30,000
Closing Date
13 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) B/R Chakeri Kanpur
GE (AF) B/R Chakeri Kanpur
PROVN OF CERTAIN REVENUE WORK, MINOR WORK AND MISC WORK UNDER AGE B/R-I CHAKERI KANPUR
2021_MES_408865_2
GE(AF)/CHK/T-51 OF 2020-21
Open Tender
Civil Works
Item Rate
120 days
GE (AF) B/R Chakeri Kanpur
Class E and cat a(i)
8 documents required · 8 mandatory
₹500
GE (AF) B/R Chakeri Kanpur
₹30,000
22 Feb 2021
30 Jan 2021
15 Feb 2021
30 Jan 2021
13 Feb 2021
1 Feb 2021
60 days
Amount
Cutting opening in bricks wall built in cement or cement lime mortar for door, windows and other openings or enlargeing existing opening, etc for cutting out defective brick work for under-pinning, including providing fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard core etc store and rubbish not exceeding 50 m complete all as specified and directed.
Dismantling mild steel windows/doors/partition of any description complete all as specified and directed.
M & L for Brick work with fly ash bricks, Straight or curved on plan exc. 6 m mean radius built in CM (1:4) complete all as specified and directed.
M&L for 15 mm thick rendering on external surface in CM (1:4) on brick masonry walls finished even & smooth without using extra cement complete all as specified and directed.
M & L for 15 mm thick rendering on Internal surface in cement mortar 1:6 on brick or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M & L preparation of new plastered surfaces on wall and applying two coats of oil bound distemper over a coat of primer including 1 to 2 mm thick Wall care putty complete all as specified and directed.
M & L preparation of newly plastered surface of wall and applying 1-2 mm thick wall care putty and applying two coat of acrylic emulsion exterior grade whether proof paint over a coat of weather resistant acrylic primer on prepared surface of wall in operation of each coat wise and after application of first coat of paint surface shall be got approved in token of their satisfactory application and there after subsequent coat shall be applied upto ten mtr height of bldg complete all as specified and directed.
S & F aluminium frame/shutter powder coated of any colour (thikness of powder coating not less than 50 micron) for doors/windows/ventilators/partition, aluminium section as under, including necessary joining cleat, glazing clips, rubber reoprene packing, handles 2 Nos in each doors/windows/vent, hinges 150 mm size for door and 100 mm size for window/vent, anodized aluminium snap boarding screws etc complete all as specified and directed. (A) Aluminium sections for Frame : (i) Jindal Section No 2425, 101.60 mm x 44.75 x 1.75 mm thick, Wt @ 1.367 Kg/RM or equivalent. (B) Aluminium Section for Shutter : (i) Bottom Rail - Jindal Section No 4530, 114.30 mm x 44.45 mm x 2.15 thick, Wt @ 1.823 Kg/RM or equivalent. (ii) Side Rail - Jindal Section No 4526, 85 mm x 44.45 mm x 1.80 mm thick Wt @ 1.302 Kg/RM.(iii) Mid Rail - Jindal Section No 4591, 83.5 mm x 44.45 mm x1.54 mm thick Wt @ 1.139 Kg/RM or equivalent (iv) Top Rail - Jindal Section No 4589, 83.5 mm x 44.45 mm x1.62 mm thick Wt @ 1.139 Kg/RM or equivalent (v) Glazing Clip - Jindal Section No 4430, 0.49 mm thick, Wt @ 0.071 Kg/RM or equivalent. Note : (i) Any other section required for doors/windows/vent/Partition will paid as per actual wt at Site. (ii) Glass/wire mesh, and other fittings material shall be measured and paid seperately.
S & F for 5.5 mm thick sheet glass, exceeding 0.50 Sqm in each pane, including coloured film of any colour, fixed to aluminium frame work with necessary glazing clips/rubber packeng/gasket screws etc complete all as specifed and as directed.
S&F mortice lock brass 4 levers vertical type of size 100mm complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store yard complete all as specified and directed.
M&L for 25 mm thick cement concrete type B0, (1:2:4)using 12.5 mm graded stone aggregate as in sub base for floor complete all as specified and directed.
M&L for 7 to 8 mm thick non skid ceramic digital tiles (Square/ rectangular) area of each tile exceeding 0.09 sqm but not exceeding 0.16 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over and including 15 mm thick screed bed or bedding in CM (1:4) complete all as specified and directed.
M&L Coloured Glazed digital ceramic tiles of size (350x250)x7 mm/ (450x350)x7mm thick or as required size on vertical surface as in dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles including cement plaster in CM (1:3) complete all as specified and directed.
S & F in repair steel water tubing medium grade, galvanised with all fittings of 15 mm bore as on wall and ceiling or laid in floors complete all as specified and directed.
Cutting chases in brick wall built in cement mortar for concealed water tubing and making good with cement mortar in (1:3) cutting depth shall not be exceeding 10 cm girth complete all as specified and directed.
S & F in repairs PVC flushing cistern, Duo Flush, push button type of 10 ltr capacity, coloured with all fittings with WC including PVC flush pipes, brackets etc. complete all as specified and directed.
S&F in repair vitreous china wash hand basin white size 550mmx400 mm including bracket but excluding taps, waste pipes, chain and plug etc complete all as specified and directed.
S&F in repair vitreous china squatting pan `Orissa ' pan pattern of size 580mmx440mm white `P' or `S' trap front back inlet ( excluding flushing cistern and flush pipes) complete all as specified and directed.
S&F in repairs chromium plated soap dish complete all as specified and directed.
S&F in repair 15mm fancy type Bib taps of PTMT any colour high pressure screwed for iron pipe and fixed (min weight 15 mm-105 gms) complete all as specified and directed.
S&F in repairs fancy type pillar taps, 15 mm dia, PTMT any colour screwed down for iron pipe (Min wt 120 gms) complete all as specified and directed.
S&F in repairs stop valve, 15 mm dia of of PTMT long shank and cup (concealed type (Minimum wt for 15 gms -110 gms) complete all as specified and directed.
S&F angle stop valve, 15 mm dia, PTMT any colour pressure screwed for iron pipe (min wt 90 gms) complete all as specified and directed.
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repairs grating round 140 mm size of PTMT (Min wt 100 gms) complete all as specified and directed.
S & F PVC waste pipe 32 mm bore for WHB/sink complete all as specified and directed.
Taking down chowkats or frames not exc 1.5 sqm each but with shutters (without taking off shutters from the frame) complete all as specified and directed.
Ditto all as per item No.29.00 here-in-before but exc 1.5 sqm but n.exec 4 sqm each.
S&F solid PVC frame (Single Rebated) of size of 50 mm x 47 mm made out of 5 mm wood grain printed PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet in opening as per specification & drawing complete all as specified and directed.
S&F 30 mm thickfactory made solid PVC door shutters (style) single side prelaminated PVC sheet used instead of plain colour PVC sheet and stile & rails having one side feathered edge on other side 10 mm 90 degree bent edge complete all as specified and directed.
S&F PVC hinges of 100 mm long complete all as specified and directed.
S&F 200 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150 mm long aluminum anodised bow handle fabricated type extruded section of complete all as specified and as directed.
S & F powder coated aluminium grill to windows/ventilators including aluminium 'F' Channel 20mm x 20mm x 2 mm mm thick, fixed all round of grill complete all as specified and as directed. Make : Deco Cat Part No 104 or Equivalent.
M&L for 12 mm thick pre-leminated particle board exterior grade prelaminated both side with decorated choice lamination with rubber beading /gasket screws complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm with stainless steel wire staplescomplete all as specified and as directed.
M&L 7mm to 8mm thick for non skid coloured ceramic tiles (squre or rectangular) area of each tile excedding 0.11 sqm but n.exc. 0.18 sqm, in floors etc. set and jointed in grey cement and pointed in white or colour cement to match the existing surfaces over & including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
Ditto all as per item No.39.00 here-in-before but as in skirting over and including 10 mm thick rendering in CM (1:4) complete all as specified and as directed.
Complete removal of existing treatment on walls/Chajjas, parapets etc and preparation of old plastered/putty surfaces on wall and applying two coats of oil bound distemper over a coat of primer after applying 1-2 mm thick wall care putty complete all as specified.
M&L for preparation of old plastered surface of wall and applying 1-2 mm thick wall care putty and applying two coat of acrylic emulsion exterior grade whether proof paint over a coat of weather resistant acrylic primer on prepared surface of wall in one operation of each coat wise and after application of first coat of paint surface shall be got approved in token of their satisfactory application and there after subsequent coat shall be applied upto 10 m height of bldg complete all as specified and directed.
Surface excavation n exec 30 cm deep and averaging 15 cm deep and getting out in hard dense soil complete all as specified and directed.
M & L for 75 mm thick cement concrete type D-2 (1:4:8) using 40mm graded aggregate as in sub base of floor finished rough to receive finishes complete all as specified and as directed.
M&L for 60 mm thickness machine pressed pre-cast concrete inter locking pavers block of any shape and size confirming to IS 15658-2006, M-35 Grade with finished by using rubber moulded technology consisting of appropriate ratio malamine base super plastisizer imported pigment and surface hardening chemical to match surface of high abresion, resistance and glazed finished over and including 25 mm thick sand cushioning complete all as specified and as directed.
M & L for for providing PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in window or door cills, lintels, bressumers, steps, quoin blocks (for user with masonry), string course, copings, kneelers apex stones, pier caps, coulumns posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bounders (for stone walling), corbels brackets etc (of any sections as indicated), with plain fair faces including chamfers weathering, throating etc including necessary form work complete all as specified and directed.
Removing excavated soil/demolished material exc 1.50 m and not exceeding 5 km depositing where directed at a level not exc 1.5 m from the starting point complete all as specified and directed.
M & L for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in sub base complete all as specified and as directed.
M&L for 40 mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in flooring, concrete finished even and smooth without using extra cement complete all as specified and directed.
M&L for sand cushinging under floor or in foundations including watering, ramming and consolidation complete all as specified and directed.
M&L for machine pressed pre-cast concrete inter locking pavers block of any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with finished by using rubber moulded technology consisting of appropriate ratio malamine base super plastisizer imported pigment and surface hardening chemical to match surface of high abresion, resistance and glazed finished with white cement pigment layer upto 10mm thick grey cement and pigment, including filling the gap between tiles and kerb stone with cement concrete type B0, (1:2:4) (12.5 mm graded aggregate) complete all as specified and as directed.
S&F Fancy type drapery rod, colored with brackets 20-25 mm bore with bracket and both end top cut to length as reqired complete all as specified and directed. Note : The fancy type top of both ends with brass/nickel chrom polish to be provided of each length of curtain rod and the rate are included in running meter of drapery rod.
M & L for PCC (1:2:4) cement concrete in type B-1, using 20 mm graded stone aggregate, as in fencing post, copping, benching or similar work complete all as specified and as directed.
Material and labour for joist channel, angle, flat or tee sections, fixed independently without connecting plates etc including cutting to any lenth, welding together or with MS wire netting, embeded in concrete, Fe-290 (Gde E-290) complete all as specified and directed.
S & F for galvanized, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts, including provision of galvanized mild steel wire, staples or steel pins, etc. complete all as specified and directed. (Each line wire to be measured).
S & F repairs for galvanized, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts, including, with and provision of galvanized mild steel wire, staples or steel pins, etc. complete all as specified and directed. (Each line wire to be measured).
Material and labour for applying three coats of white wash on newly plastered surfaces on wall including preparation of surfaces complete all as specified and directed.
Material and labour for preparation of newly or previously untreated steel or iron surfaces and applying two coats of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed.
Material and labour for preparation of old steel or iron surfaces and applying two coats of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed.
S & F coloured galvalume profile sheet in roofing shall be with feed material manufactured from 0.50 mm (minimum) base metal thickness (BMT), minimum 550 Mpa yield strength and shall confirm to physical specifications of ASTM-792 or equivalent, colour coated galvalume sheet shall have maximum pitch of 250 mm C/C and minimum 28 mm crest depth in lenght as per site requirement. The steel sheet shall be coated with hot dip metallic, aluminium Zinc alloy (55% Aluminium, 43.5% Zink, 1.5% silicon) coating AZ 150 as 150 gm/Sqm total on both sides. The contractor shall submit manufacturer test certificates for the chemical and mechanical properties, confirming genuinity of material including base metal thickness must be submitted for approval to GE prior to the installation/fixing. The manufacturer of sheet should submit related documents for expected product services performances of pre paintted metal sheet as per relevant ASTM/IS. Manufactuer's recommended installation methodologhy, all types of accessories fonsidered for roofting. Fasterns shall be coloured baked enamel supper durable, polyester with silicon coating of film thickness of minimum 25 micron (including primer) on top minimum 10 micron (including primer on interior fance. The paint shal be shade as approved by GE. The sheet shall have wide pans with minimum 2 small stiffening ribs for effective with self-drilling screws as per manufacturer instructions completed all as specified and directed . Note : Total thickness of sheet with BMT, AZ 150 coating and panting shall not be less than 0.575 mm. (2+87)
S&F 2mm thick plain, fibre glass reinforced translucent sheet, cutting to size, fixed to gate with coach screws and washer complete all as specified and directed.
M & L for hardcore of broken stone or boulders gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
M & L for 40 mm thick PCC (1:2:4) type B0, using 12.5 mm graded aggregate as in floor finished even and smooth with using extra cement complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation, manholes, sewer line, drain etc and getting out in hard/dense soil complete all as specified and directed.
M & L for providing PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in foundation filling/mass concreting complete all as specified and directed.
M & L for brick work with sub class `B' bricks, straight or curved on plan, exc 6m mean radius built in cement mortar (1:6) complete all as specified & directed.
M&L for 7 to 8 mm Coloured, matt, elevation ceramic tiles, 3-D, with high definition, digitally printed, as per ISO 13006/EN14411, 300mm x 450 mm thick or as required size on vertical surface as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles complete all as specified and directed.
M&L for 18 to 20 mm thick granite stone (of any type) work (table rubbed and polished, in steps, jambs, pillars, window cills, cooking platform and similar works set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screed bed or bedding in CM (1:4) complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations.
M & L for sand filling in floors, pavings, laid in layers any thick, spread levelled and blinded with earth inluding watering and ramming etc. complete all as specified and directed.
Returning and filling in including spreading and leveling watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
M&L for cutting holes into or through cement concrete slabs etc, reinforcement or otherwise for inserting perlins/rafters, superficial area exc 250 Sqcm but not exc 500 Sqcm and 15 cm depth complete all as specified and directed.
Cutting chases in brick wall built in cement mortar for inserting the galvalume sheet and making good, depth exc 10 cm and not exceeing 20 cm girth as directed.
S&F for steel work in tubular trusses including special shaped, washers, cutting, welding etc using ERW or induction butt welded tubes and plates (plain or chequered) channels, squares cut or notched (ordinary and counter sunk forming holes, with or withour attachment conforming to IS 1161-1998 grade St-240 complete all as specified and directed.
M&L for PCC (1:2:4) type B0, using 12.5 mm graded stone aggregate as in roof kerb, benching or mud stops, filling the brick hole or simmilar work, rounded or chamfered on edges complete all as specified and directed.
S&F wind driven turbine ventilator (Mill finish) hurricane 600 with FRP base to match roofing sheet and variable angle elbow with and including flashing sheet complete all as specified and directed. Note : Fixing shall be done by manufacturer's technician only.
Fixing olny stainless chromium plated letters of any height and any width/thickness, drilling in existing brick/concrete wall and insert the existing nuts/bolts in to hole and using adhesive to fixed the nuts/bolts, polishing/shining of old letters and making good of old surfaces up to 12 m height complete all as specified and directed. Note : All necessary arrangements for fixing of letters at height such as Scaffolding/ladders and safety eqpuipments shall be cattered by the contractors.
Dismantling in filllets rails, posts, rafters, purlins etc under Sq cm in section complete all as specified and directed.
S&F framed work such as grills, grating with ends of bars shouldered and or/riveted or forged into spkes, framed guard bars, barred iron doors, ladders framed balusters walk ways, railing, frame work of water tanks and similar work conforming to Fe-290, Gde-E-165 complete all as specified and directed.
Excavation in post holes (or similar holes) each not exceeding 0.50 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surfaces in sof/loose soil complete all as specified and directed.
SAI KRIPA BUILDERS
M/s DKS Engineering Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .